Flyover Quantity
Flyover Quantity
7
Clearing and grubbing road land including uprooting rank
vegetation, grass, bushes, shrubs, saplings and trees girth up to 300
mm, removal of stumps of trees cut earlier and disposal of
unserviceable materials and stacking of serviceable material to be
8 R.A. 1 1.02 used or auctioned, up to a lead of 1000 meters including removal and Hector 0.18 84982 15025
disposal of top organic soil not exceeding 150 mm in thickness.
Ref.:- MORT&H Cl.201
9
Preparation of land plans of road (New alignment) with fixing
boundaries on both sides of centre line of Road / Existing road up to
road boundary, including carrying out detailed plain table survey
Thane DSR along the centre line of the road, showing details of permanent /
2015-16 Item semi- permanent structures, trees, telephone-lines, pipe-lines, field-
10 1.03 Km 0.10 7788.9 810.0456
No:-3 Page bunds, cross-roads up to 100m or as directed, plotting work of
No:-238 surveyed area etc. complete.
11
Providing '7' copies of computer printouts of plans duly bound in
Thane DSR the form of booklet.
2015-16 Item
12 1.04 Job 0.10 4943.4 514.1136
No:-6 Page
No:-238
13
Thane DSR
Providing and fixing chainage, apexes, Bench Mark stone of size
2015-16 Item
14 1.05 17 x 22 x 60 cm.in cement concrete 1:4:8 block of size 45 x 45 x 60 Km 0.21 633.15 131.6952
No:-13 Page
cm. including excavation, conveyance etc. complete.
No:-235
15
1
A B C D E F G
PRE-CONSTRUCTION CONSULTANCY SERVICES (INCLUDING TEFR, DETAILED
1 Name of Project: ENGINEERING AND BID PROCESS MANAGEMENT) FOR PROPOSED PUBLIC
TRANSPORT INITIATIVES OF TMC.
2 Date: 20-11-2015
3 ABSTRACT SHEET
4 Ref.DSR Sr. No. Description Unit Quantity Rate Amount
Thane DSR
Providing tuntappa box of jungle wood of size 1.25m x 0.35m x
2015-16 Item
22 1.08 0.15m size for preserving core samples with all fixtures and fastening No 2 2919 5838
No:-5 Page
and conveying to the site office or to the head quarters as directed.
No:-230
23
Item No:-
25 1) Natural moisture content (NMC) of soils by oven drying method. No 2 256 512.4
10(1)
Item No:-
26 2) Wet and Dry Density No 2 256 512.4
10(2)
Item No:-
27 3) Sieve Analysis No 2 508 1016.4
10(6)
Item No:-
28 4) Liquid & Plastic limits No 2 381 762
10(8)
Item No:-
29 5) Shrinkage limits No 2 381 762
10(9)
Item No:-
30 6) Specific gravity No 2 508 1016.4
10(10)
31
Conducting standard penetration test on soil, sand
Thane DSR by split spoon sample for150 diameter bore hole including labour &
2015-16 Item material etc. complete. (Equipment and materials is to be supplied by
32 1.10 No 4 626 2503
No:-9 Page Department free of cost).
No:-231
33
Collecting disturbed samples of soil from bore holes as per
34 BW-1-07-a 1.11 specifications and delivering the same to the testing laboratory No 2 300 600
anywhere as directed etc. complete as specified and directed.
35
Installation of a steel portable barricade with horizontal rail 300
mm wide, 2.5 m in length fitted on a 'A' frame made with 45 x 45 x 5
mm angle iron section, 1.5 m in height, horizontal rail painted (2
36 R.A. 4 1.12 coats) with yellow and white stripes, 150 mm in width at an angle of Rmt 69 3121 214308.7
450, 'A' frame painted with 2 coats of yellow paint, complete as per
IRC:SP:55-2001
37
Providing traffic wardens for regulation of traffic during
MSRDC/200 person/
38 1.13 construction as per requirement of traffic police & as directed by 515 0
5/2.2/pg.4 day
engineers
39
40 R.A. 6 1.14 Providing cones, studs, painted drums plastic channelize. Nos. 7 894 6139
41
43
MSRDC Providing & fixing cats eye/tiger eyes at 10.0m center to center
SOR along the center and or edge of the flyover and the ramp portion and
44 1.16 on other edge of the slip road as per specification and as directed by Nos. 7 859 5899
2005/6.13.9/
Pg37 the engineer.
2
A B C D E F G
PRE-CONSTRUCTION CONSULTANCY SERVICES (INCLUDING TEFR, DETAILED
1 Name of Project: ENGINEERING AND BID PROCESS MANAGEMENT) FOR PROPOSED PUBLIC
TRANSPORT INITIATIVES OF TMC.
2 Date: 20-11-2015
3 ABSTRACT SHEET
4 Ref.DSR Sr. No. Description Unit Quantity Rate Amount
48
Empty boring through over burden including road crust up to the
49 BW-2-28-o 2.01 bottom of pile cap for all diameters of piles. Rmt
56
Excavation for foundation----------- including shoring and strutting
as necessary and disposing off excavated stuff excluding dewatering
57 2.04 Cum
if separately provided, as directed etc. complete (for depth up to 1.50
M.)
58 R.A. 8 i) earth, soil of all types, sand gravel #REF! 512 #REF!
59 R.A. 9 ii) Hard murum & boulder #REF! 639 #REF!
60
Providing and laying in situ M-20 cement concrete of
trap/granite/quartzite/gneiss metal in foundation including necessary
61 R.A.11 2.05 bailing out water, compaction and curing (using concrete mixer) Cum #REF! 8,435 #REF!
including form work Spec. No. BR-5 Page No.105 & MoRT&H Cl.
1500, 1700 & 2100
62
Providing and laying in situ M-40 RCC in open foundation, piles
caps bed block below Reinforced soil wall using stone metal,
blenching of natural and cursed sand OPC 53 grade, fly ash (max
20%) admixture including necessary dewatering, formwork to
achieve F2 finish, centering mixing in mechanized automatic batch
mix plant transporting, compacting including curing by sprinkling /
63 R.A.45 2.06 Cum #REF! 8,848 #REF!
ponding of water and finishing as directed including all leads, lift etc.
complete as per approved drawing and as per sp. and as directed by
engineer. (excluding steel reinforcement) (Ready mix Concrete only).
64
Providing and cutting bending, hooking, laying in position and tying
65 R.A.12 2.07 HYSD bars for reinforcement in Foundation as per detailed drawings MT #REF! 78,505 #REF!
for R.C.C. work.
66
3
A B C D E F G
PRE-CONSTRUCTION CONSULTANCY SERVICES (INCLUDING TEFR, DETAILED
1 Name of Project: ENGINEERING AND BID PROCESS MANAGEMENT) FOR PROPOSED PUBLIC
TRANSPORT INITIATIVES OF TMC.
2 Date: 20-11-2015
3 ABSTRACT SHEET
4 Ref.DSR Sr. No. Description Unit Quantity Rate Amount
68
Pile load test on single vertical pile in accordance with I.S. 2911 part
69 R.A.7 2.09 MT
IV.
70 a) Initial test and routine load test. 300 0
71
Carrying out Plate Load Test complete with necessary and adequate
Kent ledge loads, equipments and instruments etc. as per
72 BW-1-18 2.10 specifications for determination of bearing capacity of soil etc. No. 75,000 0.0
complete as specified and directed and submitting reports in
duplicate.
73
Carrying out Dynamic load test at 2.50 times the design load on any
dia. Of pile including all preparations for conducting test by
74 2.11 precasting required C.C hammer head and all machineries, labour etc. No.
including submitting report with graphs and interpretations complete
(excluding cost of pile).
Conducting low strain pile integrity test on RCC Bored Cast In Situ
piles using pile integrity tester equipment manufactured by pile
78 BW-5-7-d 2.12 dynamic Test. of USA or TNO of Netherlands or equivalent that No. #REF! 500 #REF!
confirms to ASTM D5882 and submitting reports in quadruplicate
appointing expert etc. complete.
79
Providing and applying one coat of epoxy primer and two coats of
coal tar epoxy paint (Total DFT = 50 + 80 + 80 = 210 microns) to
all concrete surfaces in contact with earth in foundation and
Thane DSR substructure including all cost of material, labour, transportation and
2015-16 Item preparing the surfaces by cleaning, washing, brushing, sand / grit
80 2.13 Sqm #REF! 341 #REF!
No:-75 Page blasting etc. complete as directed by Engineer and as per
No:-218 Specifications. (Paint shall be got approved from Engineer and /or
tested from approved laboratory).
86
Providing and cutting bending, hooking, laying in position and tying
87 R.A. 13 3.02 HYSD bars for reinforcement in substructure as per detailed MT #REF! 46,426 #REF!
drawings for R.C.C. work.
88
4
A B C D E F G
PRE-CONSTRUCTION CONSULTANCY SERVICES (INCLUDING TEFR, DETAILED
1 Name of Project: ENGINEERING AND BID PROCESS MANAGEMENT) FOR PROPOSED PUBLIC
TRANSPORT INITIATIVES OF TMC.
2 Date: 20-11-2015
3 ABSTRACT SHEET
4 Ref.DSR Sr. No. Description Unit Quantity Rate Amount
90
Providing and applying anticarbonation Acrylic Paint in two coats
over required coat of primer to the exposed superstructure concrete
91 BW-5-7-c 3.04 surfaces of girder and slab soffits/sides including cleaning and Sqm ### 234.00 #VALUE!
surface preparation, equipment, labors etc. complete.
97
98
4.02 Providing and cutting bending, hooking, laying in position and tying
99 R.A. 14 HYSD bars for reinforcement as per detailed drawings for R.C.C.
work.
100 Box and I Girder with Slab MT 14 80,774 1114681.2
101
Providing fusion bounded epoxy to reinforcing bars as per IS 3620
- 1933 specifications for a thickness of 175 +/- 50 microns including
testing of coating at plant, extra cost for careful handling using PVC
Thane DSR coating binding wires, instead of GI Wire touching up the material
2015-16 Item supplied repair work etc. complete as per detailed specification,
102 4.03 MT 13.80 14,715.75 203077.35
No:-73 Page (Lead up to 340Km to & fro from plant) for all diameters
No:-217 Ref.:- MoRT&H Cl.1600
103
Steel superstructure: Providing structural steel work of 100%
metalizing steel work in trusses, other similar trussed purlins and
members with all bracing, gusset plates etc. as per detailed design
and drawings or as directed by Engineer-In-Charge, including
104 Market rate 4.04 cutting, fabricating, hoisting, erecting fixing in position, making MT 0.00 154000 0.00
riveted/ bolted/welded connection and one coat of anticorrosive paint
and over it two coats of oil painting of approved quality and shade
etc. complete.
105
5
A B C D E F G
PRE-CONSTRUCTION CONSULTANCY SERVICES (INCLUDING TEFR, DETAILED
1 Name of Project: ENGINEERING AND BID PROCESS MANAGEMENT) FOR PROPOSED PUBLIC
TRANSPORT INITIATIVES OF TMC.
2 Date: 20-11-2015
3 ABSTRACT SHEET
4 Ref.DSR Sr. No. Description Unit Quantity Rate Amount
Thane DSR: Heat sealed waterproof membrane not less than 4 mm thick, as per
-2012-2013 approval to be accorded by the Engineer.
106 BR/Item 4.05 Sqm #REF! 400 #REF!
No:-50
Pgno:-171
107
108 Total Of Section 4 #REF!
109
110 5 SECTION 5: FIXED ITEMS
Drainage Spouts complete as per drawing and Technical
111 R.A.34 5.01 Nos. 20.70 1786 36970.20
specification
112
Provision of an Reinforced cement concrete crash barrier at the
edges of the road, approaches to bridge structures and medians,
constructed with M-40 grade concrete with HYSD reinforcement
conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at
expansion joints filled with pre-molded asphalt filler board, keyed to
the structure on which it is built and installed as per design given in
113 R.A.57 5.02 the enclosure to MOST circular No. RW/NH - 33022/1/94-DO III Rm 103.50 5012.00 518742.00
dated 24 June 1994 as per dimensions in the approved drawing and at
locations directed by the Engineer, all as specified
114
Supplying, fitting and fixing in position true to line and level POT-
PTFE bearing consisting of a metal piston supported by a disc or
unreinforced elastomeric confined within a metal cylinder, sealing
rings, dust seals, PTFE surface sliding against stainless steel mating
surface, complete assembly to be of cast steel / fabricated structural
steel, metal and elastomeric elements to be as per IRC: 83 part-I & II
115 R.A.20 5.03 respectively and other parts conforming to BS: 5400, section 9.1 & MT 1200 267 320400
9.2 and clause 2006 of MoRTH Specifications complete as per
drawing and approved Technical Specifications.
Ref.:- MORT&H Spec. Cl. 2000 & 2200
116
Providing and fixing modular type expansion joint material
inclusive of German imported edge beams and elastomeric strip seal
along with indigenous fabricated anchorage system for fixing the
117 R.A. 24 5.04 Rmt 24 #REF! #REF!
deck for movement of +/- 35 mm (total 60 mm) as per MORT&H
specification under supervision of specialized
118
Providing and applying hot applied thermoplastic road marking
material with glass beads extremely high skid resistance 2.5 mm
thick without primer coat (Tack coat) on Asphalt road surface. All
labour, materials, with special aggregates as specified in B.S. part - l
& all 1989 and carrying out the marking on any road in center line
and other marking continuous or intermittent 10cm. or 15cm width
119 5.05 also pedestrians crossing strips as well as spraying further quantity of Sqm
glass beads of type all uniformly into a mono layer on to the hot paint
line in quick succession of the paint spraying operation @ 250 gms
per Sqm. area as directed and as per BS/ MOST specifications in
white/yellow color.
120 R.A. 22 With hot applied thermoplastic paint for yellow Sqm #REF! 789 #REF!
121 R.A. 22 With hot applied thermoplastic paint for white Sqm #REF! 789 #REF!
122
6
A B C D E F G
PRE-CONSTRUCTION CONSULTANCY SERVICES (INCLUDING TEFR, DETAILED
1 Name of Project: ENGINEERING AND BID PROCESS MANAGEMENT) FOR PROPOSED PUBLIC
TRANSPORT INITIATIVES OF TMC.
2 Date: 20-11-2015
3 ABSTRACT SHEET
4 Ref.DSR Sr. No. Description Unit Quantity Rate Amount
124
Providing and laying not mix hot laid Dense Bituminous Macadam
Polymer Modifying Bitumen grade 40 with 4.25% bitumen content
by weight of total mix on prepared surface with specified graded
crusher aggregates for the base/ binding course including loading of
aggregates with F.E. Loader, heating of stone aggregates and bitumen
125 R.A. 31 5.07 Cum 56.93 4,733 269426.025
and mixing in modern drum mix type of hot mix plant transporting
the hot mix to work site laying the mixed material with sensor paver
finisher to the required grade, level and camber, rolling by power
roller and vibratory roller to achieve the desired density
Ref.:- MORT&H Spec. Cl. 4th Rev. 507
126
Providing and laying 25 mm thick Polymer Modifying Bituminous
concrete with 40-60 batch type HMP producing an average output of
50 tones per hour using crushed aggregates of specified grading
premixed with bituminous binder at 6.5% by weight of total mix and
filler incl. Providing anti-stripping agent.@ 0.50% of bitumen
content of, transporting the hot mix to work site with all leads and
applying a tack coat @3.75 kg/10sqm with hot bitumen of 80/100
127 R.A. 33 5.08 and laying with hydrostatic/hydraulic power finisher with sensor Cum 0.00 1,015 0
control to the required grade, level and alignment, rolling with
smooth wheeled, vibratory or tandem rollers to achieve the desired
compaction as per MoRT&H specifications clause 509 and 503.
7
THANE MUNICIPAL CORPORATION
Name of DRG. NO -
Project: DESIGN & CONSTRUCTION OF SOUTH BOUND FLYOVER AT THE JUNCTION OF ANDHERI-GHATKOPAR LINK ROAD ON EASTERN MMRDA-/MJ-
Date: EXPRESS HIGHWAY (EEH), MUMBAI BRIDGE/GAD/10
0/R0
08/12/2017
MEASUREMENT SHEET
Flyover : Chainage CH - 108.676 to CH -760.948
Solid Approach to Thane - CH - 108.676 to CH - 255.560 = 146.88 146.88
Via Duct - CH - 255.560 to CH - 655.560 = 400 400.00
Solid Approach to Mumbai - CH - 655.560 to CH - 760.948 = 105.388 105.388
TOTAL LENGTH =652.272 652.272
652.27
Spot level/contour survey at 5 mtr. X 5 mtr grid w.r.t. GTS datum level or
1.02 temporary bench mark Sqm. 1 652 27.5 17937
Taking trial bores for detailed investigations with 150 diameter boring in
overburden, hard murum, boulders including all materials such as
temporary casing pipes & accessories, grease, steel balls, drill rods, core
lifter, reaming shells, core barrels, diamonds drills, air houses, water swivels
etc. and other such materials as required, including conveying such
materials and machinery to site of works. collected and preserving the loose
1.08 samples in glass or plastic jar, collection and preservation of undisturbed
samples, water samples, wash samples as directed at site of work and
conveying the same to the head quarter of concerned office as directed etc.
complete.
Providing tuntappa core box of jungle wood of size 1.25m x 0.55m x 0.15m
1.09 size for preserving core samples with all fixtures and fastening, handled, No 22 22.00
locking arrangement etc. complete
Carrying out various tests on sub soil & rock samples as specified on
undisturbed and disturbed soil samples for characterization of soil profile at
1.10 site laboratory & submission of laboratory observation sheet, graphs etc. as
per IS 2720 (latest version) as directed by Engineer in charge.
Page 8 of 29
THANE MUNICIPAL CORPORATION
22 Total 1439.99
For Piers A1 to P9 ( 12.00 mtr C/w) (4 pile group) 10.00 7.60 5.10 0.1 38.76
Obligatory span P10 to P11 (6 pile group) 2.00 10.60 4.60 0.1 9.75
For Piers P12 to A2 ( 12.00 mtr C/w) (4 pile group) 10.00 7.60 5.10 0.1 38.76
Total 87.27
Page 9 of 29
THANE MUNICIPAL CORPORATION
Carrying out Plate Load Test complete with necessary and adequate Kent
ledge loads, equipments and instruments etc. as per specifications for
2.09 determination of bearing capacity of soil etc. complete as specified and No 1 1.00
directed and submitting reports in duplicate.
Page 10 of 29
THANE MUNICIPAL CORPORATION
Conducting low strain pile integrity test on RCC Bored Cast In Situ piles
using pile integrity tester equipment manufactured by pile dynamic Test. of
USA or TNO of Netherlands or equivalent that confirms to ASTM D5882 and
2.11 submitting reports in quadruplicate appointing expert etc. complete. No 3 3.00
Total 549.93
Total 8909.56
Page 11 of 29
THANE MUNICIPAL CORPORATION
Painting two coats after filling the surface with synthetic enamel paint in all
5.03 shades on new plastered concrete surfaces Sqm ###
2580.27
Supplying, fitting and fixing in position true to line and level POT-PTFE
bearing consisting of a metal piston supported by a disc or unreinforced
elastomeric confined within a metal cylinder, sealing rings, dust seals, PTFE
surface sliding against stainless steel mating surface, complete assembly to
be of cast steel/fabricated structural steel, metal and elastomeric elements
5.04 to be as per IRC: 83 part-I & II respectively and other parts conforming to BS: MT Nos. MT
5400, section 9.1 & 9.2 and clause 2006 of MoRTH Specifications complete
as per drawing and approved Technical Specifications. Ref.:-
MORT&H Spec. Cl. 2000 & 2200
Page 12 of 29
THANE MUNICIPAL CORPORATION
Providing and applying tack coat with bitumen emulsion using emulsion
5.07 pressure distributor at the rate of 0.20 kg per sqm on the prepared Sqm
bituminous/granular surface cleaned with mechanical broom.
Providing & laying 4mm thick heat seal waterproofing membrane for deck.
5.10 sqm 1 400 11 4400.00
Page 13 of 29
THANE MUNICIPAL CORPORATION
Page 14 of 29
THANE MUNICIPAL CORPORATION
Construction of dry lean cement concrete Sub- base over a prepared sub-
grade with coarse and fine aggregate conforming to IS: 383, the size of
coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed
15:1, aggregate gradation after blending to be as per table 600-1, cement
content not to be less than 150 kg/ cum, optimum moisture content to be
6.12 determined during trial length construction, concrete strength not to be less cum
than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid
with a paver with electronic sensor, compacting with 8-10 tonnes vibratory
roller, finishing and curing.
Construction of cement concrete kerb with channel with top and bottom
width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on
M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm
7.01 thick in PCCM20 grade, sloped towards the kerb, kerb stone with channel Rm
laid with kerb laying machine, foundation concrete laid manually, all
complete as per clause 408
Page 15 of 29
THANE MUNICIPAL CORPORATION
Provision of red fluorescent with white reflective sleeve traffic cone made of
7.06 low density polyethylene (LDPE) material with a square base of 390 x 390 No 87 86.97
x 35 mm and a height of 770 mm, 4 kg in weight, placed at 1.5 m interval, all
as per BS 873
Total 7140.13
Total 5355.10
Total 6136.36
Construction of dry lean cement concrete Sub- base over a prepared sub-
grade with coarse and fine aggregate conforming to IS: 383, the size of
coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed
15:1, aggregate gradation after blending to be as per table 600-1, cement
content not to be less than 150 kg/ cum, optimum moisture content to be
8.04 determined during trial length construction, concrete strength not to be less cum
than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid
with a paver with electronic sensor, compacting with 8-10 tonnes vibratory
roller, finishing and curing.
Page 16 of 29
THANE MUNICIPAL CORPORATION
Total 2045.45
Total 20220.43
8.05A Milling upto 60mm. Depth Asphaltic surface by using milling machine Sqm
including transportation anywhere as directed.
For existing Flyover 1 400.00 11.00 4400.00
Total 212.55
Total 4565.90
Providing and applying tack coat with bitumen emulsion using emulsion
pressure distributor at the rate of 0.20 kg per sqm on the prepared
8.07 bituminous/granular surface cleaned with mechanical broom. Sqm
Total 4565.90
Total 4250.90
Page 17 of 29
THANE MUNICIPAL CORPORATION
Total 3522.18
Total 36.57
Total 2172.54
7 mtr height, dia 130mm at bottom & 70mm at top, base plate size
220x220x12mm,foundation bolt 700mm long 26 26
Supplying & fixing following street light pole (existing pole made out of
50mm dia MS "B" Class pipe welded to 300mm long MS pole canopy suitable
dia at angle of 102.50 including having MS traingular stiffner of size
8.12 150x50x5mm thick, making arrangement for lightning bracket with pole by Each
providing suitable size heavy duty nut & bolt in canopy, painting with one
coat of approved steel primer etc. as required.
Page 18 of 29
THANE MUNICIPAL CORPORATION
DRG. NO -
Name of Project: DESIGN & CONSTRUCTION OF SOUTH BOUND FLYOVER AT THE JUNCTION OF ANDHERI-GHATKOPAR MMRDA-/MJ-
LINK ROAD ON EASTERN EXPRESS HIGHWAY (EEH), MUMBAI BRIDGE/GAD/10
Date: 08/12/2017 0/R0
Bill Of Quantites
Reference Sr. No. Description Unit Quantity Rate Amount
1 SECTION 1 : Survey and Soil Investigation
Total station survey of existing compound area showing existing plot
Thane DSR boundary, structure, electric pole, manhole, chamber, trees location
2015-16 details adjoining roads etc.
Item No:-22 1.01 Sqm. 17937 6 107625
Page No:-
244
Spot level/contour survey at 5 mtr. X 5 mtr grid w.r.t. GTS datum level or
Thane DSR temporary bench mark
2015-16
Item No:-23 1.02 Sqm. 17937 4 71750
Page No:-
244
Thane DSR
2015-16 Providing and fixing chainage, apexes, Bench Mark stone of size 17 x 22
Item No:-13 1.06 x 60 cm.in cement concrete 1:4:8 block of size 45 x 45 x 60 cm. including No. 5.22 603 3147
Page No:- excavation, conveyance etc. complete.
235
Taking trial bores for detailed investigations with 150 diameter boring in
overburden, hard murum, boulders including all materials such as
temporary casing pipes & accessories, grease, steel balls, drill rods, core
lifter, reaming shells, core barrels, diamonds drills, air houses, water
Thane DSR swivels etc. and other such materials as required, including conveying
2015-16 such materials and machinery to site of works. collected and preserving
Page No:- 1.08 the loose samples in glass or plastic jar, collection and preservation of
229/230 undisturbed samples, water samples, wash samples as directed at site of
work and conveying the same to the head quarter of concerned office as
directed etc. complete.
Thane DSR
2015-16 Providing tuntappa box of jungle wood of size 1.25m x 0.35m x 0.15m
Item No:-5 1.09 size for preserving core samples with all fixtures and fastening and No 22 2780 61160
Page No:- conveying to the site office or to the head quarters as directed.
230
Page 19 of 29
THANE MUNICIPAL CORPORATION
Thane DSR Carrying out various tests on sub soil & rock samples as specified on
2015-16 1.1 undisturbed and disturbed soil samples for characterization of soil profile
Page No:- at site laboratory & submission of laboratory observation sheet, graphs
231/232 etc. as per IS 2720 (latest version) as directed by Engineer in charge.
Item No:-
10(1) 1) Natural moisture content (NMC) of soils by oven drying method. No 22 244 5368
2 SECTION: FOUNDATION
SSR 17-18
Maharashtra Bored cast-in-situ M35 grade R.C.C. Pile excluding Reinforcement
,Item No- 2.01 complete as per Drawing and Technical Specifications and removal of
excavated earth with all lifts and lead upto 1000 m.
15.126
Ref:- MORT&H specification clause no. 1100, 1600.
1200mm dia Rmt 1,213 10,898 13220582
Page 20 of 29
THANE MUNICIPAL CORPORATION
Pile load test on single vertical pile in accordance with I.S. 2911 part IV.
R.A.7 2.08 MT
Carrying out Plate Load Test complete with necessary and adequate Kent
ledge loads, equipments and instruments etc. as per specifications for
determination of bearing capacity of soil etc. complete as specified and
BW-1-18 2.09 directed and submitting reports in duplicate. No. 1 75,000 75000
Carrying out Dynamic load test at 2.50 times the design load on any dia.
Of pile including all preparations for conducting test by precasting
required C.C hammer head and all machineries, labour etc. including
2.10 submitting report with graphs and interpretations complete (excluding No.
cost of pile).
Conducting low strain pile integrity test on RCC Bored Cast In Situ piles
BW-5-7-d 2.11 using pile integrity tester equipment manufactured by pile dynamic Test. No. 3 500 1500
of USA or TNO of Netherlands or equivalent that confirms to ASTM D5882
and submitting reports in quadruplicate appointing expert etc. complete.
3 SECTION 3: SUBSTRUCTURE
4 SECTION 4:SUPERSTRUCTURE
Page 21 of 29
THANE MUNICIPAL CORPORATION
SSR 17- Painting two coats after filling the surface with synthetic enamel paint in
18,Item No- 5.03 all shades on new plastered concrete surfaces Sqm
35.07
Anticrash barrier & Kerb paint 2580.27 62 159977
Supplying, fitting and fixing in position true to line and level POT-PTFE
bearing consisting of a metal piston supported by a disc or unreinforced
elastomeric confined within a metal cylinder, sealing rings, dust seals,
PTFE surface sliding against stainless steel mating surface, complete
SSR 17- assembly to be of cast steel / fabricated structural steel, metal and
18,Item No- 5.04 elastomeric elements to be as per IRC: 83 part-I & II respectively and MT 20400 166 3386400
13.09 other parts conforming to BS: 5400, section 9.1 & 9.2 and clause 2006 of
MoRTH Specifications complete as per drawing and approved Technical
Specifications.
Page 22 of 29
THANE MUNICIPAL CORPORATION
Providing and applying tack coat with bitumen emulsion using emulsion
pressure distributor at the rate of 0.20 kg per sqm on the prepared
R.A. 30 5.07 bituminous/granular surface cleaned with mechanical broom. Sqm 8,800.00 9 79200
Providing & laying 4mm thick heat seal waterproofing membrane for
5.10 deck. sqm 4400.00 0
Page 23 of 29
THANE MUNICIPAL CORPORATION
Construction of dry lean cement concrete Sub- base over a prepared sub-
grade with coarse and fine aggregate conforming to IS: 383, the size of
coarse aggregate not exceeding 25 mm, aggregate cement ratio not to
exceed 15:1, aggregate gradation after blending to be as per table 600-1,
SSR 17-18, cement content not to be less than 150 kg/ cum, optimum moisture
Item No- 6.12 content to be determined during trial length construction, concrete cum 277.50 2,470 685423
5.13 strength not to be less than 10 Mpa at 7 days, mixed in a batching plant,
transported to site, laid with a paver with electronic sensor, compacting
with 8-10 tonnes vibratory roller, finishing and curing.
Page 24 of 29
THANE MUNICIPAL CORPORATION
R.A. 22 With hot applied thermoplastic paint for yellow Sqm 76 736 55702
R.A. 22 With hot applied thermoplastic paint for white Sqm 13 736 9284
Construction of cement concrete kerb with channel with top and bottom
width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on
M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm
R.A. 49 7.01 Cum 252.27 9,259 2335786
thick in PCCM20 grade, sloped towards the kerb, kerb stone with channel
laid with kerb laying machine, foundation concrete laid manually, all
complete as per clause 408
MSRDC/200 7.05 Providing traffic wardens for regulation of traffic during construction as person 720.00 600 432000
5/2.2/pg.4 per requirement of traffic police & as directed by engineers /day
Provision of red fluorescent with white reflective sleeve traffic cone made
R.A. 6 7.06 of low density polyethylene (LDPE) material with a square base of 390 Nos. 87 834 72533
x 390 x 35 mm and a height of 770 mm, 4 kg in weight, placed at 1.5 m
interval, all as per BS 873
Page 25 of 29
THANE MUNICIPAL CORPORATION
Construction of dry lean cement concrete Sub- base over a prepared sub-
grade with coarse and fine aggregate conforming to IS: 383, the size of
coarse aggregate not exceeding 25 mm, aggregate cement ratio not to
exceed 15:1, aggregate gradation after blending to be as per table 600-1,
cement content not to be less than 150 kg/ cum, optimum moisture
MORTH, content to be determined during trial length construction, concrete
8.04 strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, cum
Item No- 6.2
transported to site, laid with a paver with electronic sensor, compacting
with 8-10 tonnes vibratory roller, finishing and curing.
MCGM,Item Milling upto 60mm. Depth Asphaltic surface by using milling machine
No-RW-7- including transportation anywhere as directed. Sqm 4400.00 92 404800
09
Page 26 of 29
THANE MUNICIPAL CORPORATION
7 mtr height, dia 130mm at bottom & 70mm at top, base plate size
220x220x12mm,foundation bolt 700mm long 26 10,273 268032
Supplying & fixing following street light pole (existing pole made out of
PWD 50mm dia MS "B" Class pipe welded to 300mm long MS pole canopy
chattisgard suitable dia at angle of 102.50 including having MS traingular stiffner of
h, Item No- 8.16 size 150x50x5mm thick, making arrangement for lightning bracket with Each
m 21.9 pole by providing suitable size heavy duty nut & bolt in canopy, painting
(21.9.2), P with one coat of approved steel primer etc. as required.
No-141
79163159
Total cost = 242,112,487
Page 27 of 29
THANE MUNICIPAL CORPORATION
Abstract Summary
Sr.No. Particulars Amount
1 Survey & Soil Investigation 3263718
2 Foundation 42923366
3 Substructure 11464394
4 Superstructure 60614535
5 Fixed item 22136391
6 Solid Approach 19280383
7 Miscellaneous items 82429700
TOTAL 242112487
Page 29 of 29