This document provides specifications for an electro-mechanical over current relay test kit. The kit includes an English Electric/EASUN REYROLLE over current relay that can be set from 50-200% and has a time multiplier setting of 0.1-1. It also includes a PS-SCI-SW50 source unit that provides variable AC current from 1-50 amps to test the relay. The test kit allows experiments to study the operation, time characteristics, pickup levels, and reset levels of the over current relay.

Uploaded by

Rafin Aqsa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
161 views

EM Overcurrent Relay PDF

This document provides specifications for an electro-mechanical over current relay test kit. The kit includes an English Electric/EASUN REYROLLE over current relay that can be set from 50-200% and has a time multiplier setting of 0.1-1. It also includes a PS-SCI-SW50 source unit that provides variable AC current from 1-50 amps to test the relay. The test kit allows experiments to study the operation, time characteristics, pickup levels, and reset levels of the over current relay.

Uploaded by

Rafin Aqsa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

ELECTRO- MECHANICAL OVER CURRENT RELAY (IDMT) TEST KIT

Model: PS-EM101-1

Make of the relay :

English Electric (ALSTOM) / EASUN REYROLLE

RELAY SPECIFICATION:

 C.T.SEC: 1A OR 5A* Over current relay : PS-EM101-1


 NON- DIRECTIONAL*
 PLUG SETTING: 50% - 200%*
 TIME MULTIPLIER SETTING: 0.1 – 1 ,
 OUTPUT : 8A relay 1NO. *
 Characteristics : 3sec-10times*
 Auxiliary supply : Self powered / powered *
 Construction : Draw out

SOURCE UNIT: PS-SCI-SW50

Accuracy

o The relay conforms to error class index E 7.5 as per BS 142-1966 and 7.5 as per IS 3231-1965, at ten
times reference current setting.
o The relays comply fully with the requirements of IS 3231-1965 and are suitable for use in normal tropical
environments.

Note: Only Internationally (or) Electricity Boards’ Approved Relay are used.

Advantage / Safety of relay

 The above relay is fitted in a nice 19” enclosure with handle. All the terminals of relay are brought out
through BTI-15 connectors for safety
of the relay and relay connection. Schematic block diagram of the relay is screen printed on the front
panel for easy understanding.
 The Enclosures are stackable.

* other ranges are also available


* DMT / High set also available
* Available in the 3Phase also.
THE SOURCE UNIT: Model : PS-SCI-SW50

Input voltage : 220v ac , 50hz, 500va


Output current : output current continuous variable with range selection.
No of ranges 6 : 1A, 2A, 5A, 10A, 20A & 50A - selectable
Current injection : output current short switch provided for setting the
~ output current / injection.
Burden : 3VA
Current output : pure sine wave technique
duty : Intermittent
Ammeter : MECO – 2A 3 ½ DIGIT DIGITAL

Minumum / maximum current range readable at 1A scale resolution

1A – ( 0.001 TO 1.000A), 2A – (0.002 ATO 1.000), 5A ( 0.005A –05.00A), 10A (0.01A TO 10.00A),
20A ( 0.02A – 20.00A), 50A (0.05A TO 50.00A)
Time interval meter : Selectron 0.0001 sec accuracy. (auto range / manual range
programmable)
Inbuilt ct class : 0.2/ 0.5

Special features:

 Enclosures are made from CR sheet with  Control relays and bases O/E/N or
duly galvanized and powder coated OMRON Contactors : Schneider Electric /
(texture finish). ABB / Siemens.
 Necessary diagrams screen printed  Time interval internal / external selectable.
(gloss ink and oven treated )  Potential free ‘NO’ and ‘NC’ point to be
 Necessary BTI connectors / BS-10 / BS- provided for project works.
2 Elcom make fitted.
 Built in fuse protection and built in over
current protection. Range of experiments:
 Illuminated power on / off rocker switch
provided.(Elcom)  Study of over current relay operation.
 Start / stop / reset switch- (Elcom)  Time characteristic.
 Trip status indicator  Time characteristic at different TMS
 24V SMPS source unit for Auxiliary*.  To study of operating time.
 230v AC source for Auxiliary  To Study of pick up current level.
 DUC relay output ‘NO’ or NC’  To Study drop off (reset level) current.
connection facility.  Flag or target
 Necessary patch cords and power cables  Study of draw out construction.
provided. (Elcom)  Study of % error.
 LED are fitted at schematic itself for easy
understand the operation.

Ref: B/PS/0409 , RK: 001


* Subject to change without notice

Manufactured By:
PROTECTION SYSTEMS (INDIA), M 408, 7th Cross, 3rd Main,1st Stage, Peenya Industrial Estate,
BANGALORE – 560 058 – KARNATAKA - INDIA
Phone: 091-80- 28392339, 65734515,6,7 & 8 ,TeleFax : 28395651 MOBILE:09341892339
Email : [email protected], [email protected]