Net Flow Profile
Net Flow Profile
Introduction
Aspen Hysys 8.4 used to create the PFD of Organic Rankin cycle and
determine the Performance of the cycle.
Assumptions
The evaporator and condenser assumed as isobaric.
The pump and turbine assumed adiabatic with efficiency 75%.
The following table summarizes data obtained from the simulation
Name 1 2 3 4
Vapour Fraction 0 1 0.866682234 0
- - -
Temperature [C] 146.85
29.34352609 31.75456576 31.75469055
Pressure [kPa] 3000 3000 10 10
Molar Flow [kgmole/h] 2600.120185 2600.120185 2600.120185 2600.120185
Mass Flow [kg/h] 348541.4371 348541.4371 348541.4371 348541.4371
Liquid Volume Flow [m3/h] 260.3892502 260.3892502 260.3892502 260.3892502
- - - -
Heat Flow [MW]
199.0213307 174.6213307 180.8243657 199.2860265
Name Heat
Flow(MW)
Waste heat 24.4
Pump-W 0.264695845
Power From Turbine 6.203034985
Power from 18.46166086
Condenser
Energy Streams Data
Cycle Efficiency
The total cycle energy efficiency calculated using the following equation
Where
W turbine=Power from turbine [Kw]
W pump=Pump work [Kw]
Q evaporator=Inlet waste heat [Kw]
Ƞ= efficiency
Parameter Value
Power from Turbine( kw) 6203.034985
Pump Work ( kw) 264.6958447
Inlet Waste Heat( kw) 24400
Cycle efficiency % 24.33
Conclusion
Aspen Hysys is a useful program that used to evaluate the performance of ORC
Aspen Hysys helps in calculating the required flow rate of the refrigerant .The required
flow rate of working fluid (R-245) equal 260.389 m3/h.
During the building of the simulation attention for the proper fluid package is considered
SRK and Peng-Robinson are the suitable to calculate the enthalpy and the heat flow.