Design of Pile-Stress - P214: 905 MM 7540 0.96 % Stress Check For Critical Load Case Load Comb
This document summarizes the design of a circular reinforced concrete pile using the working stress method. Key details include a pile diameter of 1000mm, concrete grade of 35MPa, rebar grade of 500MPa, and axial load and bending moment of 1250t and 62.5tm respectively. The neutral axis was calculated to be at 891mm, resulting in maximum concrete compressive stress of 20.29MPa which exceeds the allowable limit of 17.5MPa. The maximum steel tensile stress of 80.8MPa is within the allowable limit of 375MPa.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
213 views4 pages
Design of Pile-Stress - P214: 905 MM 7540 0.96 % Stress Check For Critical Load Case Load Comb
This document summarizes the design of a circular reinforced concrete pile using the working stress method. Key details include a pile diameter of 1000mm, concrete grade of 35MPa, rebar grade of 500MPa, and axial load and bending moment of 1250t and 62.5tm respectively. The neutral axis was calculated to be at 891mm, resulting in maximum concrete compressive stress of 20.29MPa which exceeds the allowable limit of 17.5MPa. The maximum steel tensile stress of 80.8MPa is within the allowable limit of 375MPa.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 4
Design of Pile-Stress -P214
Design Of Circular Cross Section ( Working Stress Method )
Grade of Concrete 35 MPa m 8.0 Grade of Steel 500 MPa s cbc 17.50 MPa s st 375 MPa
Pile Dia 1000 mm
Area 785398 mm2 Cover to CG of Main Bar 95 mm Dia of Bar 1st layer 20 mm 2nd Layer 20 mm No of bars 1st layer 12 2nd Layer 12 Stirrup dia 10 mm Effective depth 905 mm Area of Reinforcement 7540 mm2 ~ 0.96 % Stress Check for Critical Load case P ( Axial Force ) 1250 t Load Comb : M ( Bending Moment ) 62.5 tm e 0.050 m Radius of C/l Of Reinf. 405
Ast 7540 mm2
Neutral Axis Position (x) 891.0 mm
x/d 0.9845 thita 2.8922 CG from O (A) 0.003 x bar 1.6006 mm
Contact Area (B) 0.783 Area 8E+05 mm2
I0 ( C ) 0.776 Io 5E+10 mm4
Aeff 835623 mm2
Distance of CG eff from Physical Centroid
e' 1.5 mm e-e' 48.5 mm
I eff 52799072628
Distance of Neutral Axis below CG eff
I eff / Aeff (e- e') 1302.78
Compared to 392.50 -910.3
( Goal Seek Function to be used Here, Variable Neutral Axis Posi Maximum Compressive Stress in concrete 20.29 MPa > 17.50 NOT OK
Maximum Tensile Stress in steel 80.8 MPa < 375.00 OK
e Neutral Axis Position ) Design Of Circular Cross Section ( Working Stress Method ) Grade of Concrete 50 MPa m 5.6 Grade of Steel 500 MPa s cbc 25.00 MPa s st 375 MPa
Column Dia 2000 mm
Area 3141593 mm2 Cover to CG of Main Bar 50 mm Dia of Bar 1st layer 32 mm No of bars 1st layer 48 2nd Layer 0 mm 2nd Layer 48 Stirrup dia 20 mm Spacer bar dia 32 mm Effective depth 1948 mm Area of Reinforcement 38604 mm2 ~ 1.2288 % Stress Check for Critical Load case P ( Axial Force ) 1001 t Load Comb : M ( Bending Moment ) 1019.0 tm e 1.018 m Radius of C/l Of Reinf. 950
Ast 38604 mm2
Neutral Axis Position (x) 771.3 mm
x/d 0.3960 thita 1.3612 CG from O (A) 0.539 x bar 538.87 mm
Contact Area (B) 0.289 Area 1E+06 mm2
I0 ( C ) 0.051 Io 5E+10 mm4
Aeff 1335264 mm2
Distance of CG eff from Physical Centroid
e' 467.2 mm e-e' 550.8 mm
I eff 1.75438E+11
Distance of Neutral Axis below CG eff
I eff / Aeff (e- e') 238.55
Compared to 238.55 0.0
( Goal Seek Function to be used Here, Variable Neutral Axis P Maximum Compressive Stress in concrete 23.78 MPa < 25.00 OK
Maximum Tensile Stress in steel -203.5 MPa < 375.00 OK