Pvsyst Trial Pvsyst Trial Pvsyst Trial Pvsyst Trial: Grid-Connected System: Simulation Parameters
Pvsyst Trial Pvsyst Trial Pvsyst Trial Pvsyst Trial: Grid-Connected System: Simulation Parameters
PVsyst TRIAL
Simulation variant :
Simulation parameters
New simulation variant
Simulation date
Simulation for the
System type
08/03/19 15h41
10th year of operation
No 3D scene defined
Collector Plane Orientation Tilt 30° Azimuth 0°
Models used Transposition Perez Diffuse Perez, Meteonorm
Horizon Average Height 5.8°
Near Shadings No Shadings
PV Array Characteristics
PVsyst TRIAL
PV module Si-poly Model Poly 285 Wp 72 cells
Original PVsyst database Manufacturer Generic
Number of PV modules In series 14 modules In parallel 72 strings
Total number of PV modules Nb. modules 1008 Unit Nom. Power 285 Wp
Array global power Nominal (STC) 287 kWp At operating cond. 257 kWp (50°C)
Array operating characteristics (50°C) U mpp 452 V I mpp 569 A
Total area Module area 1956 m² Cell area 1764 m²
PVsyst TRIAL
Pnom ratio 1.26
PVsyst TRIAL
Incidence effect, ASHRAE parametrization IAM = 1 - bo (1/cos i - 1) bo Param. 0.05
PVsyst TRIAL
PV Array
Inverter
Inverter pack
User's needs
Horizon
Nb. of modules
Model
Nb. of units
Unlimited load (grid)
Average Height
1008
12 kWac inverter
19.0
5.8°
Pnom total
Pnom
Pnom total
Diffuse Factor
287 kWp
12.00 kW ac
228 kW ac
0.95
Albedo Factor 100 % Albedo Fraction 0.57
Height [°] 0.0 6.1 5.8 2.5 8.8 10.1 10.4 9.1 6.5 5.2 4.8 0.0
Azimuth [°] -120 -92 -77 -67 -46 -31 -12 20 35 49 64 120
PVsyst TRIAL 90
75
7
12h
13h
6
Plane: tilt 30°, azimuth 0°
5
11h
10h
14h
60
3
9h
[[°]]
15h 2
height
PVsyst TRIAL
45
Sun
8h
16h
30 1: 22 june
2: 22 may - 23 july
7h
3: 20 apr - 23 aug
17h
4: 20 mar - 23 sep
5: 21 feb - 23 oct
15
6: 19 jan - 22 nov
6h
7: 22 december
Behind Behind
the plane the plane
0
180 150 120 90 60 30 0 -30 -60 -90 -120 -150 -180
Azimuth [[°]]
PVsyst TRIAL
PVsyst Evaluation mode
PVSYST V6.70 08/03/19 Page 3/5
PVsyst TRIAL
Inverter pack
User's needs
Specific prod.
287 kWp
12.00 kW ac
228 kW ac
1247 kWh/kWp/year
Performance Ratio PR 75.24 %
Normalized productions (per installed kWp): Nominal power 287 kWp Performance Ratio PR
6 0.8
Lc : Collection Loss (PV-array losses) 1.04 kWh/kWp/day PR : Performance Ratio (Yf / Yr) : 0.752
Ls : System Loss (inverter, ...) 0.08 kWh/kWp/day 0.7
5 Yf : Produced useful energy (inverter output) 3.42 kWh/kWp/day
PVsyst TRIAL
[kWh/kWp/day]
0.6
Performance Ratio PR
4
0.5
Energy
3 0.4
Normalized
0.3
2
0.2
1
0.1
0 0.0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
PVsyst TRIAL
New simulation variant
Balances and main results
PVsyst TRIAL
October 137.6 77.90 22.63 131.9 119.4 28.92 28.21 0.745
November 143.9 80.30 21.61 125.8 113.2 27.73 27.04 0.748
December 133.9 72.30 22.00 113.4 101.8 24.81 24.16 0.742
Legends: GlobHor Horizontal global irradiation GlobEff Effective Global, corr. for IAM and shadings
DiffHor Horizontal diffuse irradiation EArray Effective energy at the output of the array
T Amb Ambient Temperature E_Grid Energy injected into grid
GlobInc Global incident in coll. plane PR Performance Ratio
PVsyst TRIAL
PV Array
Inverter
Inverter pack
User's needs
Nb. of modules
Model
Nb. of units
Unlimited load (grid)
1008
12 kWac inverter
19.0
PVsyst TRIAL
-2.9% Far Shadings / Horizon
-2.9% IAM factor on global
-3.0% Soiling loss factor
-2.4%
0.0%
0.0%
Mismatch loss, modules and strings
Ohmic wiring loss
Array virtual energy at MPP
PVsyst TRIAL
PVsyst Evaluation mode
PVSYST V6.70 08/03/19 Page 5/5
PVsyst TRIAL
PV Array
Inverter
Inverter pack
User's needs
The probability distribution of the system production forecast for different years is mainly dependent
on the meteo data used for the simulation, and depends on the following choices:
Meteo data source Meteonorm 7.1
Meteo data Kind Not defined Year 1995
Specified Deviation Year deviation from aver. 3%
Year-to-year variability Variance 0.5 %
PVsyst TRIAL
The probability distribution variance is also depending on some system parameters uncertainties
Specified Deviation PV module modelling/parameters 1.0 %
Inverter efficiency uncertainty 0.5 %
Soiling and mismatch uncertainties 1.0 %
0.45
0.40
0.35
Probability distribution
0.30
Probability
0.25
0.20
P90 = 350 MWh
0.15
0.05
PVsyst TRIAL
0.00
335 340 345 350 355 360 365 370 375 380
E_Grid system production MWh