0% found this document useful (0 votes)
114 views1 page

Zero Halogen EP Welding Cable 105ºC Industrial Grade: Specifications & Standards Construction

The document describes a 600V arc welding cable with an ethylene propylene rubber jacket rated for 105°C. It provides specifications for the cable including conductor size and stranding, insulation thickness, diameter, weight, and ampacity ratings. The cable is designed for secondary voltage resistance welding and motor/generator/battery applications.

Uploaded by

Andri Yunafrison
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
114 views1 page

Zero Halogen EP Welding Cable 105ºC Industrial Grade: Specifications & Standards Construction

The document describes a 600V arc welding cable with an ethylene propylene rubber jacket rated for 105°C. It provides specifications for the cable including conductor size and stranding, insulation thickness, diameter, weight, and ampacity ratings. The cable is designed for secondary voltage resistance welding and motor/generator/battery applications.

Uploaded by

Andri Yunafrison
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

600V ARC - WELDING CABLE

Zero Halogen EP Welding Cable 105ºC


Industrial Grade

SPECIFICATIONS & STANDARDS


According to UL 1581

CONSTRUCTION:
Conductors: Flexible stranded bare copper per ASTM B-172 Class K
Separator: Tape separator between the conductor and insulation
Jacket: Ethylene Propylene Rubber (EPR) Class 45, 105˚C Table 50.55 of UL 1581
Color of jacket: Black 6AWG - 500MCM;
Red 6AWG–4/0

FEATURES APPLICATION

- Excellent flexibility - Secondary voltage resistance welding leads


- Ozone, sun, weather resistant - Leads for motors, generators, batteries
- Rated and flexible at –40ºC
- Oil resistant
- Heat resistant at 105ºC

Maximum
Power Power Nominal Ampacity
Part Nominal Approx. Direct Current
Conductor Conductor Insulation 40ºC Ambient
Number O.D. Weight Resistance
Size Stranding Thickness Temp.
20C Ω/km

AWG or MCM No. of Stranding inches inches mm Ibs/1000 ft kgs/km Ω/km A


WC6 6 AWG 253/30 0.060 0.319 8.1 115 171 1.38 133
WC4 4 AWG 403/30 0.060 0.366 9.3 169 252 0.865 179
WC2 2 AWG 636/30 0.060 0.429 10.9 255 379 0.549 237
WC1 1 AWG 798/30 0.080 0.508 12.9 303 451 0.436 284
WC1/0 1/0 AWG 1016/30 0.080 0.555 14.1 396 589 0.345 327
WC2/0 2/0 AWG 1261/30 0.080 0.598 15.2 482 719 0.276 377
WC3/0 3/0 AWG 1590/30 0.080 0.673 17.1 595 887 0.219 449
WC4/0 4/0 AWG 2007/30 0.080 0.716 18.2 734 1092 0.173 514
WC250 250 MCM 2399/30 0.095 0.866 22.0 907 1349 0.147 577
WC350 350 MCM 3327/30 0.095 0.953 24.2 1203 1790 0.106 719
WC500 500 MCM 4746/30 0.095 1.130 28.7 1734 2580 0.0743 908
WC6-RED 6 AWG 253/30 0.060 0.319 8.1 115 171 1.38 133
WC4-RED 4 AWG 403/30 0.060 0.366 9.3 169 252 0.865 179
WC2-RED 2 AWG 636/30 0.060 0.429 10.9 255 379 0.549 237
WC1-RED 1 AWG 798/30 0.080 0.508 12.9 303 451 0.436 284
WC1/0-RED 1/0 AWG 1016/30 0.080 0.555 14.1 396 589 0.345 327
WC2/0-RED 2/0 AWG 1261/30 0.080 0.598 15.2 482 719 0.276 377
WC3/0-RED 3/0 AWG 1590/30 0.080 0.673 17.1 595 887 0.219 449
WC4/0-RED 4/0 AWG 2007/30 0.080 0.716 18.2 734 1092 0.173 514
(1) Ampacity – Free air measured; Based on continuous duty at 90°C conductor temperature

STANDARD PRINT LEGEND:


TF CABLE (SIZE) ARC WELDING CABLE 600V OIL RESISTANT -40˚C +105˚C

SPECIAL FACTORY OPTIONS:


Conductor: Class M (AWG 34) stranding
Jacket: Neoprene®
CSA: 1101275 -FT2; Oil Resistant (Optional)
Neoprene is a registered trademark of DuPont

Issue 4.3, November 2010 phone: 630-406-9000 www.tfcable.com 31