0% found this document useful (0 votes)
70 views

Codeline Drawing 80E30

The document provides a parts list and specifications for a fiberglass reverse osmosis pressure vessel. It lists 17 parts with descriptions and materials. It also provides design details like pressure and temperature ratings as well as precautions for installation and use.

Uploaded by

hargote_2
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
70 views

Codeline Drawing 80E30

The document provides a parts list and specifications for a fiberglass reverse osmosis pressure vessel. It lists 17 parts with descriptions and materials. It also provides design details like pressure and temperature ratings as well as precautions for installation and use.

Uploaded by

hargote_2
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

DWG PART

QTY DESCRIPTION MATERIAL


REF NUMBER
SHELL
Filament Wound Epoxy/Glass composite - Head
01 1 99301 SHELL
locking grooves integrally wound in place.

HEAD
02 2 51050 Bearing Plate 6061-T6 as per SB-221

03 2 96003 Sealing Plate Engineering Thermoplastic.

04 2 50607 Feed/Conc Port SS-316L as per SA-312

05 2 45247 Port Retainer Stainless Steel.

06 2 97980 Permeate Port Engineering Thermoplastic.

07 2 45066 Port Nut Engineering Thermoplastic.

08 2 96000 Head Seal Ethylene Propylene - O Ring.

09 4 45312 Port Seal Ethylene Propylene - O Ring.

HEAD INTERLOCK
10 2 47336 Retaining Ring SS-316 as per SA-479

VESSEL SUPPORT

11 2+ 52169 Saddle Engineering Thermoplastic.

+ 45042 Strap Assy. 304 Stainless Steel - PVC cushion


12 2

++ 46265 Strap screw. 5/16-18 UNC, 2.5'' L, 18-8 Stainless Steel.


13 4

ELEMENT INTERFACE

14 2 A/R Adapter Engineering Thermoplastic.

15 4 A/R PWT Seal Ethylene Propylene - O - Ring

16 2 52245 Adapter seal Ethylene Propylene - O - Ring

17 1 45069 Thrust Ring Engineering Thermoplastic.


+ ++
3& 6 Each Furnished With Length code 4 & above.
RATING:
PRECAUTIONS: ORDERING:
DESIGN PRESSURE…………..…………....300 PSI
(2.07 MPa) DO…read, understand and follow all Using the chart below, please check the Please note that we require your
MAX. OPERATING TEMP……...…………...120°F instructions; failure to take every precaution features you require and fax them with membrane brand and model number
(49°C) will void warranty and may result in vessel your purchase order to our customer when ordering. If this information is not
MIN. OPERATING TEMP……...……………...20°F failure service department for expedited initially available, you may provide it at
(-7°C) DO…mount the shell on horizontal members at processing. a later date by checking the appropriate
FACTORY TEST PRESSURE………CE / ASME span “S” using complaint vessel supports For optional materials and/or features box below.
450 / 330 PSI furnished; tighten hold down straps just snug not listed below, please consult factory
(3.1Mpa) / (2.27 MPa) DO…provide overpressure protection for vessel for pricing and availability.
BURST PRESSURE……..…………….…..1800 PSI set at not more than 105% of design pressure
(12.4 MPa) DO…inspect end closures regularly; replace
components that have deteriorated and VESSEL LENGTH CODE – please check one
INTENDED USE: correct causes of corrosion
MODEL 80E30 -1 -2 -3 -4 -5 -6 -7 -8
The CodeLine Model 80E30 Fiberglass RO Pressure
Vessel is designed for continuous, long term use as a DO NOT… make rigid piping connections to
MEMBRANE BRAND AND MODEL – please check one and fill in information
housing for reverse osmosis membrane elements to ports or clamp vessel in any way that resists
desalt typical brackish waters at pressures up to 300 growth of fiberglass shell under pressure;
Please supply adapters for the following membrane brand and specific model
psi. Any make of eight-inch nominal diameter spiral- ∆DIA = 0.015 in. (0.4mm) and ∆L = 0.2 in. Brand_________________________Model_______________________
wound element is easily accommodated; the (5mm) for a length code –8 vessel
appropriate interfacing hardware for the element DO NOT… hang piping manifolds from ports or
CERTIFICATION REQUIRED
specified is furnished with the vessel. use vessel in any wa
y to support other components; branch ASME Stamped and National Board Registered (please consult factory for pricing)
The CodeLine Model 80E30 is designed in connection piping may be simply supported (ASME Section X)
accordance with the engineering standards of the between the header and port; maximum
Boiler and Pressure Vessel Code of the American weight of branch piping; feed/concentrate – CE Marked
Society of Mechanical Engineers (ASME Code) 16 lbs (7.3 kg); permeate – 8 lbs (3.6 kg) Standard, Certified by Pentair.
Section X. At small additional cost, vessels can be DO NOT… operate vessel at pressures and
inspected during construction by an ASME temperatures in excess of its rating
Authorized inspector and ASME Code stamped. DO NOT… operate vessel without permeate EXTERIOR FINISH – please check one
ports internally connected with a complete
set of elements and interconnecting Standard – white high-gloss RAL 9003 polyurethane coating.
The CodeLine Model 80E30 must be installed,
hardware Option – optional colors are available for 50 or more vessels per order.
operated and maintained in accordance with the listed
DO NOT… operate vessel with permeate Call factory for pricing details.
precautions and good industrial practice to assure
safe operation over a long service life. pressure in excess of 125 psi at 120°F
MATERIAL OPTIONS
(0.86 MPa @ 49°C)
The high performance reinforced plastic shell must DO NOT… overtighten the connection to the Standard – All materials as per drawing 99111 on the first page.
be allowed to expand under pressure; undue restraint permeate port (hand-tighten plus one-quarter
Customer specified materials: -
at support points or piping connections can cause turn, check for leaks)
DO NOT… tolerate leaks or allow end closures (Please consult the factory, as these options will affect pricing and vessel lead-time.)
leaks to develop in the shell. The end closure,
incorporating close fitting, interlocking metal to be routinely wetted in any way
components, must be kept dry and free of corrosion; DO NOT… pressurize vessel until double- For complete information on proper use of
deterioration can lead to catastrophic mechanical checking to verify that the retaining ring is this vessel please refer to the 80E series
failure of the head. completely inside the groove USER’S GUIDE Bulletin 523004.
DO NOT… work on any component until first
The end closures, incorporating close-fitting, verifying that pressure is relieved from
interlocking metal components, must be kept dry and vessel
free of corrosion; deterioration can lead to DO NOT… operate outside the pH range 3-11.
catastrophic mechanical failure of the heads.

Pentair will assist the purchaser in determining the


suitability of this standard vessel for their specific
operating conditions. The final determination
however, including evaluation of the standard
material of construction for compatibility with the
specific corrosive environment, shall be the
responsibility of the purchaser.

Specifications are subject to change without notice.


DWG.No. 99111-P © Pentair Page 2 of 2