Nitrogen generator

NitroSource® HiFluxx

NitroSource unit
NitroSource®
Capacity up to 5000 Nm3/hr
Features
- Produces nitrogen from compressed air
- Can operate with existing central compressed air system
- Nitrogen purity up to 99.5%
- Capacity up to 5000 Nm³/hr
- Compressed air pre-treatment section included
- Minimum maintenance
- Digital data management
- Easy to expand
- Modular design

Product description and their sub-units can be con- trouble free operation with almost
Parker nitrogen generators are nected and controlled as one ge- no maintenance. The generator
based on Parker hollow fibre nerator. The NitroSource includes is ready to operate as soon as
membrane technology, which a high quality compressed air the compressed air supply is
makes it possible to separate filtration stage. connected.
air into nitrogen and an oxygen- This optimises the inlet com-
enriched air stream. The Nitro- pressed air quality, ensuring long The NitroSource offers an unlim-
Source industrial nitrogen genera- membrane life. The generator ited supply of nitrogen and can be
tor easily enables you to produce is equipped with a digital data connected to an external storage
nitrogen from compressed air. management system to monitor, vessel. This will ensure that the
store and communicate param- system is able to cope with peak
The NitroSource consists of a eters such as pressure, flow and demand in applications where the
main-unit that can be expanded residual oxygen concentration. nitrogen demand is variable.
with a maximum of 5 additional
subunits. Thanks to the master/ The installation has virtually no
slave feature, up to 11 main-units moving parts, resulting in reliable,

Main-unit Digital data management Easy start-up


- Robust industrial design - Data logging - Connect air supply
- Compact and modern - Status information - Connect power
- High quality pre-filtration stage - System set-up information - Vent permeate
- Maintenance indication - Easy set-up wizard
Sub-unit - Extensive data exchange
- Nitrogen modules facilities Maintenance
- Individual filtration - Detailed alarm functions - Easy access
- Easy to add to existing - Remote control option - Only occasional filter exchange
NitroSource required
Global design - Fork-lift truck access points
Master/slave option - Multi-language operation
- 11 main-units each with up to 5 - Universal power supply
sub-units can function as one - Choice of measurement units
generator
- Back-up option Easily expandable
- Multiple main-units equally used - Modular construction
- Data management and control - Easy to connect
via master unit - Up to 5 sub-units per main-unit
Specifications
Minimum nitrogen production capacity
Capacity [Nm³/hr] at nominal conditions: ambient temperature 20˚C, ambient pressure 1013 mbar(a).
Inlet pressure 7 bar(g)

Nitrogen purity % 99.5 99 98 97 96 95


Capacity per unit in Nm³ /hr 6.0 9.4 16.2 22 28 34
Main-unit 6.0 9.4 16.2 22 28 34
Main-unit + 1 sub-unit 12.0 18.8 32,4 44 56 68
Main-unit + 2 sub-units 18.0 28.2 48.6 66 84 102
Main-unit + 3 sub-units 24.0 37.6 64.8 88 112 136
Main-unit + 4 sub-units 30.0 47.0 81.0 110 140 170
Main-unit + 5 sub-units 36.0 56.4 97.2 132 168 204

For calculation of the capacity at feed pressures other than the nominal feed pressure: multiply the nominal
capacity by the correction factor for the pressure at the inlet of the NitroSource.

Pressure bar(g) 4 5 6 7 8 9 10 11 12 13
Correction factor 0.35 0.51 0.76 1.00 1.20 1.40 1.60 1.90 2.10 2.40

Technical data

Data/NitroSource Unit NitroSource Main-unit NitroSource Sub-unit


Max. delivery pressure Inlet pressure minus pressure drop (2 bar max.)
Max. feed pressure 13 bar(g)
Temperature 10-40°C
Residual oil content < 3.0 mg/m3
Presssure dew point < 5°C
Noise level < 45 dB(A)
Connections Air inlet: G 1” - Outlet G 1” - Permeate vent: 110 mm Nitrogen outlet:G 1” -
Permeate vent: 110 mm
Electrical data 90-250 VAC/50-60 Hz
Output signals 0 - 10 volt: oxygen, inlet pressure, flow rate (optional)
RS232: datalogging
Potential free relay: compressor start/stop, alarm, drain
Input Digital input: switch on/off
Dimensions (HxWxD) 1928 x 725 x 490 mm 1928 x 725 x 270 mm
Weight 180 kg 95 kg

NitroSource Main-unit NitroSource Sub-unit


Part numbers 159.003552 159.003553
Maintenance kits - yearly 159.003569 159.003570
Oxygen transmitter 159.002284 - replace once every 3 years

Reference condition for Nm³ = 20˚C and 1013 mbar(a)


© 2008 Parker Hannifin Corporation S3.1.073b 2008