22-JUL-2083 14:58 FROM + 652 2513 1872 TO 28459295 P6585, DAVID S. K. AU & ASSOCIATES LTD. China United Centre, 26th Floor, 28 Marble Road, North Point, HONG KONG Tel : (852) 2560 8811 Fax : (852) 2513 1828Email : [email protected] hk FAX TRANSMISSION To : Hip Hing Construction Co. Lid From TK Yu Attn, : Mr. Kam W Mak Tel.No. : 25608811 Tel. No. : 25259251 OurRef. : DA00028/ 124 FaxNo. 28459295 Date: 22" July 2003 $0006/H200308- No, of i YourRef. : ToseWMKOL pages” 1 including this one) Should you not receive all the pages, please contact me at your earliest convenience. statement of plate lond test Further to your letter and the enclosed method of statement dated 19” July 2003, we have the following comments on your submitted method of statement: S 3 & 2 é & & 2 ty ‘A sketch showing the arrangement of the equipment should be submitted. Maximum test load on each position should be stated. Please clarify in using the test load pressure of 600 kPa. Please revise your method of statement in according to the site formation drawing no. 1DA00028/1/NA/001 (revision C). aepe ‘Should you have any queries, please contact the undersigned @ 25608811 Regards, Yu ec. Chi Lin Nunnery - Ms. Daisy Sin 22L20071450° 7" " TOMPHINGCONSTGRUUP™ “fBqesz2sist072 ee ae BL IB el Hip Hing Construction Co, Ltd. Member of NWS Holdings mT Our Ref $0015/11200308-003/K WM/KOL ANN it 2003Y139614 24 July 2003 David S.K. Au & Associates Ltd. 26/F., China United Centre, 28 Marble Road, North Point, Hong Kong. Aitn.: Mr. Patrick P.C. Chu Dear Sir, ‘Hammer Hill Road Park, Diamond Hill Revised Method Statement of Plate Load Test Further to the comments stated on your fax ref. no.: DA00028/1139 dated 22" July 2003 from Mr. TK. Yu, we submit herewith the captioned revised method statement for your review and approval Ifyou have any question, please do not hesitate to contact the undersigned ‘Thank you for your kind attention. Yours faithfully, HIP HING CONSTRUCTION CO. LTD. , Project Manager) Encl. ce ChiLinNunnery = Ms. Daisy Sin }w/o L&B }wio KWM/KOLIkh SAYREEAUPTASTASA IR AWS TOU LY (852) 2525 9251 MHA (852) 2045 9209 20IF, New World Tower, 16-18 Queen's Road Central, Hong Kong Tel (852) 2525 9251 Fax (852) 2845 9295 "Web Site: lip: /hwiw hiphing.com hk Emai: [email protected] hk. FUGRO TECHNICAL SERVICES LIMITED ———e Mitefns Dison, Ta :vase2eoeos3 eae Hg Dacooren cen, Baeza MateriaLab Le TES ace peak eae, mal abla com Tai Lam, Tuen Mun, NT, Hong Kong Method Statement for Plate Load Test Client : Hip Hing Construction Co., Ltd. Project : Hammer Hill Road Park, Kowloon (H200308) Maximum Load : 600 kPa No. of Tests : As advised by ClienvEngineer. Location of Tests : As advised by Client/Engineer Eguipment : Rigid circular steel plate of size 300mm dia. A jack of suitable capacity Calibrated load cel/proving ring. 4 Dial gauges readable to 0.01mm and complying with AS2103 : 1978 Suitable kentledge system Deen Plate load test procedure 1. Level and prepare the area to be covered by the test plate. Remove any extraneous materials, Bed the plate on 10mm (approx) layer of standard sand, ensuring the plate is level. 2. Setup the kentledge system, hydraulic jack system and the loading device. The height measured from the test location to the underside of the kentledge system should be approximately 1m high. (Ensure the kentledge system is steady and not prone to movement). 3. Setup the reference beam, ensuring the beam is stable. Attach the dial gauges to the beam ensuring they are situated mutually at right angles to one another and at an equal distance from the centre of the test plate. (If required, the level of the reference beam should be recorded by the Client). 4. Start the 1" cycle of loading. Increase the load pressure beneath the plate to 200kPa slowly and evenly in increments of 100kPa. Maintain each increment until the rate of settlement of the plate is equal to or less than 0.01mm in 1 minute. Record the settlement at the end of each increment. 5. After step 4, unload the pressure on the plate in increments of 100kPa to zero. Record the rebound unt it is equal to of less than 0.01 mm in 41 minute. 6. The level of the plate after unloading is measured and adopted as the base datum for the main-load cycle. ra by Figo Techie Seven Und Rayne reread cme wih pe! won appeal rm Conan. seus Te coor dca ‘k Membar of the Fugro Group eee oasnety

You might also like