Calcu. For Module-A Non Typ. (3rd) 03
Calcu. For Module-A Non Typ. (3rd) 03
:
Project :
STRUCTURAL ENGINEERING SHEET Ho Chi Minh, Vietnam
Check of Curtain Wall Frames Issue Date :
Subject :
EuroWindow 24th/Oct./2011
Yhs International LTD. Date : REV. No. (
Reviewed :
Prepared by : T. Hoshino Name : )REV. Date :
6-1. Module-A1 / Male(Mm) & Female(Mf) Louver Unit Mullion for L6 Podium Floor (5500mm)
1680 N/m2
Mf Mm
L1
A B Mb B B
ω X
def.W
L
Mw
L2
W1 W2
Bending stress at male mullion : σ1 = M1 / Zxm ×γm = 62 N/mm2 γm = 1.2 (Material Factor)
Allowable bending stress : Ps (BS8118) = 107 N/mm2
Safety Factor : 1.72 > 1.0 (O.K)
Bending stress at female mullion : σ2 = M2 / Zxf ×γm = 47 N/mm2 γm = 1.2 (Material Factor)
Allowable bending stress : Ps (BS8118) = 52 N/mm2
Safety Factor : 1.10 > 1.0 (O.K)
- 20 -
VIETCOMBANK TOWER, Document No. :
Project :
STRUCTURAL ENGINEERING SHEET Ho Chi Minh, Vietnam
Check of Curtain Wall Frames Issue Date :
Subject :
EuroWindow 24th/Oct./2011
Yhs International LTD. Date : REV. No. (
Reviewed :
Prepared by : T. Hoshino Name : )REV. Date :
6-2. Module-A1 / Intermediate Louver Unit Mullion (Mi) for L6 Podium Floor (5500mm)
1680 N/m2
Mi
L1
A B Mb B B
ω X
def.W
L
Mw
L2
W2 W1
Bending moment : Mw = {RA ((L22-L12)/(2L2)) - ω((L22-L12)/(2L2))2 / 2 } ×γf = 3340636 N.mm γf = 1.2 ( Load Factor )
Bending stress at male mullion : σ1 = Mw / Zxi ×γm = 85 N/mm2 γm = 1.2 (Material Factor)
Allowable bending stress : Ps (BS8118) = 110 N/mm2
Safety Factor : 1.30 > 1.0 (O.K)
Deflection : def.w = { 5 ω L24 /( 384 E Ixi ) } - ( Mb L22 / ( 16 E Ixi )) = 11.28 mm < 20mm (O.K)
( L2 / def.w : deflection ) = 1/ 401 < 1/180 (O.K)
The lesser of span/180 or 20mm
- 21 -
VIETCOMBANK TOWER, Document No. :
Project :
STRUCTURAL ENGINEERING SHEET Ho Chi Minh, Vietnam
Check of Curtain Wall Frames Issue Date :
Subject :
EuroWindow 24th/Oct./2011
Yhs International LTD. Date : REV. No. (
Reviewed :
Prepared by : T. Hoshino Name : )REV. Date :
6-3. Module-D1 / Male(Mm) & Female(Mf) Glass Unit Mullion for L6 Podium Floor (5500mm)
1680 N/m2
C
Horizontal frame spacing : W1 = 285 mm
L1
B Horizontal frame spacing : W2 = 1215 mm
L1
A
B Mw B B
ω X
L
def.W
W1 W2
L2
Calculation model against wind load
A A A
MODEL BENDING MOMENT DEFLECTION
Bending moment : Mw = {ω( L13+L23 ) / ( 8 ( L1+L2 ) } ×γf = 3266393 N.mm γf = 1.2 ( Load Factor )
Bending moment at male mullion : M1 = Mw x ( Ixm / Ix ) = 1882450 N.mm
Bending moment at female mullion : M2 = Mw x ( Ixf / Ix ) = 1383943 N.mm
Bending stress at male mullion : σ1 = M1 / Zxm ×γm = 62 N/mm2 γm = 1.2 (Material Factor)
Allowable bending stress : Ps (BS8118) = 107 N/mm2
Safety Factor : 1.73 > 1.0 (O.K)
Bending stress at female mullion : σ2 = M2 / Zxf ×γm = 47 N/mm2 γm = 1.2 (Material Factor)
Allowable bending stress : Ps (BS8118) = 52 N/mm2
Safety Factor : 1.11 > 1.0 (O.K)
- 22 -
VIETCOMBANK TOWER, Document No. :
Project :
STRUCTURAL ENGINEERING SHEET Ho Chi Minh, Vietnam
Check of Curtain Wall Frames Issue Date :
Subject :
EuroWindow 24th/Oct./2011
Yhs International LTD. Date : REV. No. (
Reviewed :
Prepared by : T. Hoshino Name : )REV. Date :
6-4. Module-D1 / Intermediate Glass Unit Mullion (Mi) for L6 Podium Floor (5500mm)
1680 N/m2
C
Horizontal frame spacing : W1 = 285 mm
L1
B Horizontal frame spacing : W2 = 1215 mm
L1
Mi
A
B Mw B B
ω X
L
def.W
W2 W1
L2
Calculation model against wind load
A A A
MODEL BENDING MOMENT DEFLECTION
Reaction force : RA = { (ωL1/2) - (ω(L13+L23)) / (8L1(L1+L2)) }×γf = -2720 N γf = 1.2 ( Load Factor )
Reaction force : RC = { (ωL2/2) - (ω(L13+L23)) / (8L2(L1+L2)) }×γf = 2722 N γf = 1.2 ( Load Factor )
Reaction force : RB = { (ωL - RA - RB }×γf = 8314 N γf = 1.2 ( Load Factor )
Bending moment : Mw = {ω( L13+L23 ) / ( 8 ( L1+L2 ) } ×γf = 3266393 N.mm γf = 1.2 ( Load Factor )
Bending stress at male mullion : σ1 = Mw / Zxi ×γm = 83 N/mm2 γm = 1.2 (Material Factor)
Allowable bending stress : Ps (BS8118) = 110 N/mm2
Safety Factor : 1.33 > 1.0 (O.K)
Deflection : def.w = { 5 ω L24 /( 384 E Ixi ) } - ( Mw L22 / ( 16 E Ixi )) = 7.84 mm < 20mm (O.K)
( L2 / def.w : deflection ) = 1/ 581 < 1/180 (O.K)
The lesser of span/180 or 20mm
- 23 -
VIETCOMBANK TOWER, Document No. :
Project :
STRUCTURAL ENGINEERING SHEET Ho Chi Minh, Vietnam
Check of Curtain Wall Frames Issue Date :
Subject :
EuroWindow 24th/Oct./2011
Yhs International LTD. Date : REV. No. (
Reviewed :
Prepared by : T. Hoshino Name : )REV. Date :
°Outer Corner
110.76°
1680 N/m2
L1
B Mw B B
W2 W1
ω X
def.W
L
L2
Calculation model against wind load
ωx
W2 W1
A A A
ωy MODEL BENDING MOMENT DEFLECTION
W2x W1x
Reaction force : RAx = { (ωx L1/2) - (ωx (L13+L23)) / (8L1(L1+L2)) }×γf = -2265 N γf = 1.2 ( Load Factor )
Reaction force : RCx = { (ωx L2/2) - (ωx (L13+L23)) / (8L2(L1+L2)) }×γf = 2267 N γf = 1.2 ( Load Factor )
Reaction force : RBx = { (ωx L - RA - RB }×γf = 6924 N γf = 1.2 ( Load Factor )
Reaction force : RAy = { (ωy L1/2) - (ωy (L13+L23)) / (8L1(L1+L2)) }×γf = -495 N γf = 1.2 ( Load Factor )
Reaction force : RCy = { (ωy L2/2) - (ωy (L13+L23)) / (8L2(L1+L2)) }×γf = 495 N γf = 1.2 ( Load Factor )
Reaction force : RBy = { (ωy L - RA - RB }×γf = 1513 N γf = 1.2 ( Load Factor )
Bending moment : Mwx = {ωx ( L13+L23 ) / ( 8 ( L1+L2 ) } ×γf = 2720295 N.mm γf = 1.2 ( Load Factor )
Bending stress at male mullion : σx = Mwx / Zx ×γm = 36 N/mm2 γm = 1.2 (Material Factor)
Bending moment : Mwy = {ωy ( L13+L23 ) / ( 8 ( L1+L2 ) } ×γf = 594579 N.mm γf = 1.2 ( Load Factor )
Bending stress at male mullion : σy = Mwy / Zy ×γm = 15 N/mm2 γm = 1.2 (Material Factor)
- 24 -
VIETCOMBANK TOWER, Document No. :
Project :
STRUCTURAL ENGINEERING SHEET Ho Chi Minh, Vietnam
Check of Curtain Wall Frames Issue Date :
Subject :
EuroWindow 24th/Oct./2011
Yhs International LTD. Date : REV. No. (
Reviewed :
Prepared by : T. Hoshino Name : )REV. Date :
Deflection : def.wx = { 5 ωx L24 /( 384 E Ix ) } - ( Mwx L22 / ( 16 E Ix )) = 3.56 mm < 20mm (O.K)
( L2 / def.w : deflection ) = 1/ 1280 < 1/180 (O.K)
The lesser of span/180 or 20mm
Deflection : def.wy = { 5 ωy L24 /( 384 E Iy ) } - ( Mwy L22 / ( 16 E Iy )) = 2.36 mm < 20mm (O.K)
( L2 / def.w : deflection ) = 1/ 1926 < 1/180 (O.K)
The lesser of span/180 or 20mm
- 25 -
VIETCOMBANK TOWER, Document No. :
Project :
STRUCTURAL ENGINEERING SHEET Ho Chi Minh, Vietnam
Check of Curtain Wall Frames Issue Date :
Subject :
EuroWindow 24th/Oct./2011
Yhs International LTD. Date : REV. No. (
Reviewed :
Prepared by : T. Hoshino Name : )REV. Date :
°Outer Corner
115.87°
1680 N/m2
B
B
Supported length : L = 5500 mm
Supported length : L1 = 950 mm
Supported length : L2 = 4550 mm
Mc2
Mc2 ω1
ω1
LL
C
L2
C C
ω2
L1
B Mw B B X
A ω
L
def.W
L2
W2 W1
95
Xs
A A A
Calculation model against wind load MODEL BENDING MOMENT DEFLECTION
50 50
Reaction force : RA = { (ωL1/2) - (ω(L13+L23)) / (8L1(L1+L2)) }×γf = -3808 N γf = 1.2 ( Load Factor )
Reaction force : RC = { (ωL2/2) - (ω(L13+L23)) / (8L2(L1+L2)) }×γf = 3811 N γf = 1.2 ( Load Factor )
Reaction force : RB = { (ωL - RA - RB }×γf = 11639 N γf = 1.2 ( Load Factor )
Bending moment : Mw = {ω( L13+L23 ) / ( 8 ( L1+L2 ) } ×γf = 4572862 N.mm γf = 1.2 ( Load Factor )
Bending moment at intermediate mullion : M1 = Mw x ( Ixi / Ix ) = 3445062 N.mm
Bending moment at S/S female : M2 = Mw x ( 3Ixs / Ix ) = 1127800 N.mm
Bending stress at male mullion : σ1 = M1 / Zxi ×γm = 87 N/mm2 γm = 1.2 (Material Factor)
Allowable bending stress : Ps (BS8118) = 110 N/mm2
Safety Factor : 1.26 > 1.0 (O.K)
Bending stress at S/S frame : σ2 = M2 / Zxs ×γm = 115 N/mm2 γm = 1.2 (Material Factor)
Allowable bending stress : Ps (Grade304) = 210 N/mm2
Safety Factor : 1.82 > 1.0 (O.K)
- 26 -
VIETCOMBANK TOWER, Document No. :
Project :
STRUCTURAL ENGINEERING SHEET Ho Chi Minh, Vietnam
Check of Curtain Wall Frames Issue Date :
Subject :
EuroWindow 24th/Oct./2011
Yhs International LTD. Date : REV. No. (
Reviewed :
Prepared by : T. Hoshino Name : )REV. Date :
°Outer Corner
115.94°
1680 N/m2
B
Supported length : L = 5500 mm
Supported length : L1 = 950 mm
Supported length : L2 = 4550 mm
Mc2
ω1
L
C C
ω2
L1
B Mw B B X
A ω
L
def.W
L2
W2 W1
95
Xs
A A A
Calculation model against wind load MODEL BENDING MOMENT DEFLECTION
50 50
Reaction force : RA = { (ωL1/2) - (ω(L13+L23)) / (8L1(L1+L2)) }×γf = -3630 N γf = 1.2 ( Load Factor )
Reaction force : RC = { (ωL2/2) - (ω(L13+L23)) / (8L2(L1+L2)) }×γf = 3633 N γf = 1.2 ( Load Factor )
Reaction force : RB = { (ωL - RA - RB }×γf = 11096 N γf = 1.2 ( Load Factor )
Bending moment : Mw = {ω( L13+L23 ) / ( 8 ( L1+L2 ) } ×γf = 4359327 N.mm γf = 1.2 ( Load Factor )
Bending moment at intermediate mullion : M1 = Mw x ( Ixi / Ix ) = 3284191 N.mm
Bending moment at S/S female : M2 = Mw x ( 3Ixs / Ix ) = 1075136 N.mm
Bending stress at male mullion : σ1 = M1 / Zxi ×γm = 83 N/mm2 γm = 1.2 (Material Factor)
Allowable bending stress : Ps (BS8118) = 110 N/mm2
Safety Factor : 1.32 > 1.0 (O.K)
Bending stress at S/S frame : σ2 = M2 / Zxs ×γm = 110 N/mm2 γm = 1.2 (Material Factor)
Allowable bending stress : Ps (Grade304) = 210 N/mm2
Safety Factor : 1.91 > 1.0 (O.K)
- 27 -
VIETCOMBANK TOWER, Document No. :
Project :
STRUCTURAL ENGINEERING SHEET Ho Chi Minh, Vietnam
Check of Curtain Wall Frames Issue Date :
Subject :
EuroWindow 24th/Oct./2011
Yhs International LTD. Date : REV. No. (
Reviewed :
Prepared by : T. Hoshino Name : )REV. Date :
L1
B Mw B B
W2 W1
ω def.W
L
X
L2
Calculation model against wind load
ωx A A A
MODEL BENDING MOMENT DEFLECTION
W2 W1
Reaction force : RAx = { (ωx L1/2) - (ωx (L13+L23)) / (8L1(L1+L2)) }×γf = -1286 N γf = 1.2 ( Load Factor )
Reaction force : RCx = { (ωx L2/2) - (ωx (L13+L23)) / (8L2(L1+L2)) }×γf = 1287 N γf = 1.2 ( Load Factor )
Reaction force : RBx = { (ωx L - RA - RB }×γf = 3931 N γf = 1.2 ( Load Factor )
Reaction force : RAy = { (ωy L1/2) - (ωy (L13+L23)) / (8L1(L1+L2)) }×γf = -190 N γf = 1.2 ( Load Factor )
Reaction force : RCy = { (ωy L2/2) - (ωy (L13+L23)) / (8L2(L1+L2)) }×γf = 190 N γf = 1.2 ( Load Factor )
Reaction force : RBy = { (ωy L - RA - RB }×γf = 580 N γf = 1.2 ( Load Factor )
Bending moment : Mwx = {ωx ( L13+L23 ) / ( 8 ( L1+L2 ) } ×γf = 1544264 N.mm γf = 1.2 ( Load Factor )
Bending stress at male mullion : σx = Mwx / Zx ×γm = 18 N/mm2 γm = 1.2 (Material Factor)
Bending moment : Mwy = {ωy ( L13+L23 ) / ( 8 ( L1+L2 ) } ×γf = 227716 N.mm γf = 1.2 ( Load Factor )
Bending stress at male mullion : σy = Mwy / Zy ×γm = 10 N/mm2 γm = 1.2 (Material Factor)
- 28 -
VIETCOMBANK TOWER, Document No. :
Project :
STRUCTURAL ENGINEERING SHEET Ho Chi Minh, Vietnam
Check of Curtain Wall Frames Issue Date :
Subject :
EuroWindow 24th/Oct./2011
Yhs International LTD. Date : REV. No. (
Reviewed :
Prepared by : T. Hoshino Name : )REV. Date :
Deflection : def.wx = { 5 ωx L24 /( 384 E Ix ) } - ( Mwx L22 / ( 16 E Ix )) = 1.43 mm < 20mm (O.K)
( L2 / def.w : deflection ) = 1/ 3183 < 1/180 (O.K)
The lesser of span/180 or 20mm
Deflection : def.wy = { 5 ωy L24 /( 384 E Iy ) } - ( Mwy L22 / ( 16 E Iy )) = 0.80 mm < 20mm (O.K)
( L2 / def.w : deflection ) = 1/ 5683 < 1/180 (O.K)
The lesser of span/180 or 20mm
- 29 -
VIETCOMBANK TOWER, Document No. :
Project :
STRUCTURAL ENGINEERING SHEET Ho Chi Minh, Vietnam
Check of Curtain Wall Frames Issue Date :
Subject :
EuroWindow 24th/Oct./2011
Yhs International LTD. Date : REV. No. (
Reviewed :
Prepared by : T. Hoshino Name : )REV. Date :
°Outer Corner
90°
Max. Wind pressure : Po = 1680 N/m2
L1
B Mw B B
W2 W1
ω def.W
L
X
Calculation model against wind load L2
ωx A A A
MODEL BENDING MOMENT DEFLECTION
W2 W1
Reaction force : RAx = { (ωx L1/2) - (ωx (L13+L23)) / (8L1(L1+L2)) }×γf = -1750 N γf = 1.2 ( Load Factor )
Reaction force : RCx = { (ωx L2/2) - (ωx (L13+L23)) / (8L2(L1+L2)) }×γf = 1751 N γf = 1.2 ( Load Factor )
Reaction force : RBx = { (ωx L - RA - RB }×γf = 5350 N γf = 1.2 ( Load Factor )
Reaction force : RAy = { (ωy L1/2) - (ωy (L13+L23)) / (8L1(L1+L2)) }×γf = -192 N γf = 1.2 ( Load Factor )
Reaction force : RCy = { (ωy L2/2) - (ωy (L13+L23)) / (8L2(L1+L2)) }×γf = 192 N γf = 1.2 ( Load Factor )
Reaction force : RBy = { (ωy L - RA - RB }×γf = 588 N γf = 1.2 ( Load Factor )
Bending moment : Mwx = {ωx ( L13+L23 ) / ( 8 ( L1+L2 ) } ×γf = 2101816 N.mm γf = 1.2 ( Load Factor )
Bending stress at male mullion : σx = Mwx / Zx ×γm = 25 N/mm2 γm = 1.2 (Material Factor)
Bending moment : Mwy = {ωy ( L13+L23 ) / ( 8 ( L1+L2 ) } ×γf = 230969 N.mm γf = 1.2 ( Load Factor )
Bending stress at male mullion : σy = Mwy / Zy ×γm = 10 N/mm2 γm = 1.2 (Material Factor)
- 30 -
VIETCOMBANK TOWER, Document No. :
Project :
STRUCTURAL ENGINEERING SHEET Ho Chi Minh, Vietnam
Check of Curtain Wall Frames Issue Date :
Subject :
EuroWindow 24th/Oct./2011
Yhs International LTD. Date : REV. No. (
Reviewed :
Prepared by : T. Hoshino Name : )REV. Date :
Deflection : def.wx = { 5 ωx L24 /( 384 E Ix ) } - ( Mwx L22 / ( 16 E Ix )) = 1.95 mm < 20mm (O.K)
( L2 / def.w : deflection ) = 1/ 2339 < 1/180 (O.K)
The lesser of span/180 or 20mm
Deflection : def.wy = { 5 ωy L24 /( 384 E Iy ) } - ( Mwy L22 / ( 16 E Iy )) = 0.81 mm < 20mm (O.K)
( L2 / def.w : deflection ) = 1/ 5603 < 1/180 (O.K)
The lesser of span/180 or 20mm
- 31 -
VIETCOMBANK TOWER, Document No. :
Project : Ho Chi Minh, Vietnam
STRUCTURAL ENGINEERING SHEET
Check of Curtain Wall Frames Issue Date :
Subject :
EuroWindow 24th/Oct./2011
Yhs International LTD. Date : REV. No. (
Reviewed :
Prepared by : T. Hoshino Name : )REV. Date :
B B B
Ag
35
X
ωx
40
A B
4.3
ω
20
Mw
L
def.W
207.5
167.5
L
2
40
A A A
145.5
- 32 -
VIETCOMBANK TOWER, Document No. :
Project :
STRUCTURAL ENGINEERING SHEET Ho Chi Minh City, Vietnam
Structural Calculation for Issue Date :
Subject :
EuroWindow Typical fastener portion 24th/Oct./2011
Yhs International LTD. Date : REV. No. ( )
Reviewed :
Prepared by : T. Hoshino Name : REV. Date :
L7
Uf
1000
1150
Ti1
Gn Ti1
Fu
5500
Ag
4500
Mf Mf Mm
3600
CHILLER ROOM
MECH. ROOM
Gn
Ti1
Ti1
Vs
750
s Ft
Lm Gn L6
162.5
965 535
Vs
s
1500
CW UNIT WIDTH
- 33 -
VIETCOMBANK TOWER, Document No. :
Project :
STRUCTURAL ENGINEERING SHEET Ho Chi Minh City, Vietnam
Structural Calculation for Issue Date :
Subject :
EuroWindow Typical fastener portion 24th/Oct./2011
Yhs International LTD. Date : REV. No. ( )
Reviewed :
Prepared by : T. Hoshino Name : REV. Date :
Tolerance
±15mm
Wa b
Filet Weld
Rn1
50
120
Rn2 Rn1
Mi Mf Mm
Wg= 7300 N
- 34 -
VIETCOMBANK TOWER, Document No. :
Project :
STRUCTURAL ENGINEERING SHEET Ho Chi Minh City, Vietnam
Structural Calculation for Issue Date :
Subject :
EuroWindow Typical fastener portion 24th/Oct./2011
Yhs International LTD. Date : REV. No. ( )
Reviewed :
Prepared by : T. Hoshino Name : REV. Date :
L2
Rn1
Shear stress : τs1 = Q1 / Ae×γm = 3650 / 84.3×1.2 = 51.8 N/mm2 Q1
T2 T1
γm = 1.2 (Material Factor)
Allowable shear stress : Pv ( BS3506 ) = 145N/mm2
L1
Combined stress for D.L : τs1 / Pv + σt1 / Pt = 51.8 / 145 + 38.1 / 174 = 0.58 < 1.0 ( O,K )
L4
Bending moments : Ma = T1×L3 + Q2×L4
: Ma = 3447×50 + 7300×( 16+25 ) L3 = 50mm
: Ma = 471650 N.mm L4 = 16mm
- 35 -
VIETCOMBANK TOWER, Document No. :
Project :
STRUCTURAL ENGINEERING SHEET Ho Chi Minh City, Vietnam
Structural Calculation for Issue Date :
Subject :
EuroWindow Typical fastener portion 24th/Oct./2011
Yhs International LTD. Date : REV. No. ( )
Reviewed :
Prepared by : T. Hoshino Name : REV. Date :
T1
Shear force : Q1 = Rn1 / 2 = 3447 / 2 = 1724 N Rn1
L7
Shear stress : τs1 = Q1 / Ae×γm = 1724 / 157×1.2 = 13.2 N/mm2 Q1
γm = 1.2 (Material Factor)
L5 L6
Allowable shear stress : Pv ( BS3506 ) = 145N/mm2
Tensile stress : σt1 = T1 / 2Ae ×γm = 7162 / ( 2×157 )×1.2 = 27.3 N/mm2
Allowable axial stress : Pt ( BS 3506 ) = 174N/mm2
γm = 1.2 (Material Factor)
Combined stress for D.L + W.L : τs1 / Pv + σt1 / Pt = 13.2 / 145 + 27.3 / 174 = 0.25 < 1.0 ( O,K )
X
: Rn1 = 3447 N
270
b-section Section property b -Section
Section area : Ax = 3700 mm2
Section modulus : Zx = 100200 mm3
- 36 -
VIETCOMBANK TOWER, Document No. :
Project :
STRUCTURAL ENGINEERING SHEET Ho Chi Minh City, Vietnam
Structural Calculation for Issue Date :
Subject :
EuroWindow Typical fastener portion 24th/Oct./2011
Yhs International LTD. Date : REV. No. ( )
Reviewed :
Prepared by : T. Hoshino Name : REV. Date :
L9
Allowable shear stress : Pv ( BS5950 ) = 165N/mm2
Q1
L8
Tensile stress : σt1 = T1 / Ax × γm = 7300 / 3700×1.2 = 2.0 N/mm2
Allowable axial stress : Pt ( BS5950 ) = 275N/mm2 L8 =176mm
L9 =231mm
Bending stress : σb1 = Mb / Zx × γm = 2320000 / 100200×1.2 = 23.2 N/mm2
Allowable bending stress : Pb ( BS5950 ) = 275N/mm2
Lw2
Weld-section Section property
Weld size : S = 6mm
Throat thickness : a = S×1/√2 = 6×1/√2 = 4.2mm Lw1
- 37 -
VIETCOMBANK TOWER, Document No. :
Project :
STRUCTURAL ENGINEERING SHEET Ho Chi Minh City, Vietnam
Structural Calculation for Issue Date :
Subject :
EuroWindow Typical fastener portion 24th/Oct./2011
Yhs International LTD. Date : REV. No. ( )
Reviewed :
Prepared by : T. Hoshino Name : REV. Date :
L10
Embedded Chanel Anchor
Fy
L8 =176mm
Fz Mb
Q1 L9 L9 =231mm
L10 =110mm
Q3
L8
- 38 -
VIETCOMBANK TOWER, Document No. :
Project :
STRUCTURAL ENGINEERING SHEET Ho Chi Minh City, Vietnam
Structural Calculation for Issue Date :
Subject :
EuroWindow Typical fastener portion 24th/Oct./2011
Yhs International LTD. Date : REV. No. ( )
Reviewed :
Prepared by : T. Hoshino Name : REV. Date :
- 39 -