0% found this document useful (0 votes)
48 views

(A) Concrete Mix Design

This document provides details of 20 concrete mix design tests conducted between November 2017 to March 2019. It includes information on the material types and sources tested, test dates, results received dates, and signatures. The tests were conducted to determine the mix designs for concrete grades ranging from 25 to 40 using various cement and aggregate sources.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
48 views

(A) Concrete Mix Design

This document provides details of 20 concrete mix design tests conducted between November 2017 to March 2019. It includes information on the material types and sources tested, test dates, results received dates, and signatures. The tests were conducted to determine the mix designs for concrete grades ranging from 25 to 40 using various cement and aggregate sources.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

(A) Concrete Mix Design

Testing Test Result Result


No. of Signature Signature of
Sr. No Date Lab Material Type Source of material Received Pass or
samples of PMC RVNL
Address Date Fail

Standard Shree Cement 43 grade


Design Mix-
1 28-11-17 Testing Fine Aggregate-Source-Banas 1 06-01-18
35.
Laboratory Combined coarse aggregate-20 MM (Bilua)

Standard Shree Cement 43 grade


Design Mix-
2 28-11-17 Testing Fine Aggregate-Source-Banas 1 06-01-18
40.
Laboratory Combined coarse aggregate-20 MM (Bilua)

Standard Shree Cement 43 grade


Design Mix-
3 28-11-17 Testing Fine Aggregate-Source-Badankulan, MP 1 06-01-18
40.
Laboratory Combined coarse aggregate-20 MM (Bilua)

Standard Shree Cement 43 grade


Design Mix-
4 28-11-17 Testing Fine Aggregate-Source-Badankulan, MP 1 06-01-18
35.
Laboratory Combined coarse aggregate-20 MM (Bilua)

Standard Ultratech Cement 43 grade


Design Mix-
5 12-01-18 Testing Fine Aggregate-Source-Banas 1 04-02-18
35.
Laboratory Combined coarse aggregate-20 MM (Bilua)

Standard Ultratech Cement 43 grade


Design Mix-
6 12-01-18 Testing Fine Aggregate-Source-Banas 1 04-02-18
40.
Laboratory Combined coarse aggregate-20 MM (Bilua)

Standard Shree Cement PP grade


7 23-04-18 Testing Design Mix-25 Fine Aggregate-Source-Sindh 1 12-05-18
Laboratory Combined coarse aggregate-20 MM (Bilua)

Standard Ultratech Cement PP grade


8 23-04-18 Testing Design Mix-25 Fine Aggregate-Source-Sindh 1 12-05-18
Laboratory Combined coarse aggregate-20 MM (Bilua)
Testing Test Result Result
No. of Signature Signature of
Sr. No Date Lab Material Type Source of material Received Pass or
samples of PMC RVNL
Address Date Fail

Standard Ultratech Cement 43 grade


Design Mix-
9 04-04-18 Testing Fine Aggregate-Source-Sindh 1 12-05-18
40.
Laboratory Combined coarse aggregate-20 MM (Bilua)

Standard Ultratech Cement 43 grade


Design Mix-
10 04-04-18 Testing Fine Aggregate-Source-Sindh 1 12-05-18
35.
Laboratory Combined coarse aggregate-20 MM (Bilua)

Standard shree Cement 43 grade


Design Mix-
11 07-04-18 Testing Fine Aggregate-Source-Sindh 1 24-04-18
40.
Laboratory Combined coarse aggregate-20 MM (Bilua)

Standard shree Cement 43 grade


Design Mix-
12 07-04-18 Testing Fine Aggregate-Source-Sindh 1 24-04-18
35.
Laboratory Combined coarse aggregate-20 MM (Bilua)

Aggregate-10, 20mm
M.E
Fine Aggregate:- 60 Kg (Sindh River)
13 30-07-18 Testing Design Mix-25 1 11-08-18
Cement (Shree Cement)-50Kg
Laboratory
Water -50Ltr
Aggregate-10, 20mm
M.E
Design Mix- Sand:- 180 Kg (Sindh River)
14 16-11-18 Testing 1 31-12-18
35. Cement (Shree Cement)- 100Kg
Laboratory
Water -65 Ltr
Aggregate-10, 20mm
M.E
Sand:- 30 Kg (Sindh River)
15 19-11-18 Testing Design Mix-25 1 21-01-19
Cement (Shree Cement)- 50 Kg
Laboratory
Water -50 Ltr
Aggregate-10, 20mm
M.E
Sand:- 30 Kg (Sindh River)
16 11-12-18 Testing Design Mix-25 1 05-01-19
Cement (Ultratech Cement)- 50 Kg
Laboratory
Water -50 Ltr
Testing Test Result Result
No. of Signature Signature of
Sr. No Date Lab Material Type Source of material Received Pass or
samples of PMC RVNL
Address Date Fail
Aggregate-10, 20mm
M.E Sand:- 30 Kg (Sindh River)
Design Mix-35
17 24-01-19 Testing Cement (Ultratech Cement)- 1 27-03-19
& 40
Laboratory Water -100 Ltr
Admixture-2 Kg
Aggregate-10, 20mm
M.E Sand:- 30 Kg (Sindh River)
Design Mix-35
18 24-01-19 Testing Cement (Birla Uttam Cement) 1 27-03-19
& 40
Laboratory Water -100 Ltr
Admixture-2 Kg
Aggregate-10, 20mm
M.E Sand:- 90 Kg (Sindh River)
19 25-02-19 Testing Design Mix-20 Cement (Ultra Cement)-50 Kg 1 26-03-19
Laboratory Water -40 Ltr
Admixture-10 Kg
Aggregate-10, 20mm 60 Kg
M.E M-Sand:-70 Kg
Mix Design M-
20 13-03-19 Testing Cement (Ultra-Tech Cement)-50 Kg 1 26-03-19
25
Laboratory Water -20 Ltr
Admixture-5 Kg
Aggregate-10, 20mm 60 Kg
M.E M-Sand:-70 Kg
Mix Design M-
21 13-03-19 Testing Cement (Shree Cement)-50 Kg 1 26-03-19
25
Laboratory Water -20 Ltr
Admixture-5 Kg
Aggregate-10, 20mm 60 Kg
M.E M-Sand:-70 Kg
Mix Design M-
22 13-03-19 Testing Cement (Ultratech Cement)-50 Kg 1 25-03-19
35
Laboratory Water -20 Ltr
Admixture-5 Kg