P442 Test Procedure

p442

Uploaded by

Humayun Ahsan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 6
TEST PROCEDURE FOR P442 TEST EQUIPMENT : OMICRON [NOTO : IN PSL [PROGRAMMABLE SCHEME LOGIC] Assign any trip Input signal TO faultrecord trigger output signal } SOTF: TOR: GOTO DISTANCE SCHEMES IN MAIN MENU GOTO SOTF/TOR MODE ENABLE SOTF ALL ZONES. [i.e make to 1] MAKE OTHER SETTINGS DISABLE [Le. make @ ONLY J SET SOTF DELAY = 105 [MIN= 10S ; MAX =3.6 Ks] GOTO STATE SEQUENCER IN OMICRON 1* stage APPLY NOMINAL V & 1 [Le. 63.5v & 1A ]FOR3 PH UPTO 1 SEC. 2" stage APPLY 0 V &0A FOR ALL 3 PHI UPTO 11 see 3" stage APPLY 0 V & 12 A FOR ALL 3 PH UPTO 1 SEC. RELAY WILL TRIP IN SOT#/TOR TRIP, GOTO DISTANCE SCHEMES IN MAIN MENU GOTO SOTF/TOR MODE ENABLE TOR ALL ZONES. | i.e. make 0 to 1] MAKE OTHER SETTINGS DISABLE [Le. make @ ONLY ] DEFAULT TOR DELAY = 200 ms GOTO STATE SEQUENCER IN OMICRON 1™ stage APPLY NOMINAL V & I [Le. 63.5 v & 14] FOR3 PH UPTO 1 SEC. 2™ stage APPLY 0 V & 0 A FOR ALL 3 PH UPTO 300 msec 3" stage APPLY 0 V & 1.2 A FOR ALL3 PH UPTO 1 SEC. © RELAY WILLTRP IN SOTE/TOR TRIP. CARRIER AIDED TRIP: . . © GOTO DISTANCE SCHEMES IN MAIN MENU © GOTO STANDARD MODE o SBLECT P.U.PZ2 {NOTO; IN PSL [PROGRAMMABLE SCHEME LOGIC] Assign any OPTO Input signal TO distance channel reciev output signal ] © ENERGISE THE CORRESPONDING OPTO & APPLY AZ2 FAULT co RELAY WILL TRIP IN TI! time & distance Aided Trip Z2 Signal appear IN FAULRECORD. © FOR OTHER ZONES RELAY WILL TRIP IN CORRESPONDING ZONE TIME DELAY THOUGH THE CARRIER IS RECIVED, WEEK INFEED: o GOTO DISTANCE SCHEMES IN MAIN MENU o GOTO STANDARD MODE o SELECT P.U.P 22 o GOTO WI: Mode Status & Assign Trip & Echo o GOTO WI: Single Pole & Assign Enabled. o SET WI: Thres = 45 V [NOTO : IN PSL [PROGRAMMABLE SCHEME LOGIC] Assign any OPTO Input signal TO distance channel reciev output signal & Assign Distance Signal Send Input signal TO Any Output Signal output signal] o ENERGISE THE CORRESPONDING OPTO & APPLY LESS THAN 43 V. o RELAY WILL TRIP IN WEEK INFEED TRIP & Signal Send O/P Relay should Operate 9. If The Voltage 18 NOT LESS THAN 45V RELAY WON'T TRIP & ECHO back the Carrier [ie. Distance Signal will Send ] VT FUSE FAIL ; © GOTO SUPERVISION IN THE MAIN MENU o SET VTS TIME DELAY = 1 SEC o SET VTS 12 & Ie Inh = 50.00 Ma [ NOTE : THE ABOVE SETTING IS FOR 1 PH, 2 PH VT FUSE FAIL) © GOTO STATE SEQUENCER IN OMICRON © 1* stage APPLY NOMINAL V&l [Le 63.5v&1A]FOR3 PH UPTO 15SEC, o of stage APPLY 0 V FOR FOR ANY IPH OR 2 PH FOR 2 SEC WITHOUT CHANGE IN NOMINAL 3 PH CURRENT. © VT FALL INDICATION WILL APPEAR IN THE FAULT RECORD. DISTANCE PROTECTION WILL GET BLOCKED DURING REAL FUSEFAIL, © DURING 2“ STAGE, IF THE NEGATIVE SEQUENCE CURRENT & ZERO SEQUENCE CURRENT IS MORE THAN $0.0 mA RELAY WILL TAKE IT AS A FAULT & GIVE THE TRIP ah’ NO VT FAIL INDICATION. WILL APPEAR. ef wD wo © GOTO SUPERVISION IN THE MAIN MENU AGAIN oT 0 SETDETRCT 3P ENABLED ae A get” » SET Threshold 3P = 30 V v a) ° ay vw 0 SET DELTAI> 100.0 Ma “y SM we © GOTO STATE SEQUENCER IN OMICRON & o i stage APPLY NOMINAL V & I [Le. 63.5v&1A]FOR3 PH UPTO 1 SEC. oi ge stage APPLY 0 V FOR FOR ALL 3PH FOR 2 SEC WITHOUT CHANGE IN NOMINAL 3 PH CURRENT, ° VT FAIL INDICATION WILL APPEAR IN THE FAULT RECORD. Lease peuinal . Nonuinall O6+5v by o get eek

You might also like