12 | UP.DATE ISSUE 02 2015 COPYRIGHT © 2015 THE BRITISH CHAMBER OF COMMERCE IN INDONESIA
Michael Dobie, CEng Bob Scouller
EARTHQUAKE DAMAGE IN PADANG SUMATRA, SHOWING EXAMPLE OF INCORRECT WEAK COLUMN AND FICE works for Tensar is engaged as a
STRONG BEAM DESIGN CONTRIBUTING TO DAMAGE International Limited, Consultant in the
a company which Mining and Resource
develops and provides Infrastructure
The results of these studies have study concludes that for low rise solutions to civil areas and serves
now been published as part of structures, good building construction engineering problems on the Committee
using reinforced soil of the Institution
the new Seismic Design Code for requirements and details will provide techniques. He is a civil of Civil Engineers,
Indonesia. There is no longer a adequate protection to inhabitants in engineer specialising (UK), Jakarta Local
single seismic hazard map, but a most cases. in the geotechnical Association. Bob
field. He is a Chartered has been involved
series of maps devised to provide a Engineer and the in earthquake
more comprehensive assessment of The study and new recommendations Country Representative rectification in Flores,
of the Institution (Maumare) Padang,
potential risk and severity of seismic prioritise structures in order of of Civil Engineers Bougainville (PNG)
shaking. The recommendations may “survival importance”. Highest priority in Indonesia, and and Aceh after the
has worked in the 2004 tsunami. Bob
be applied to a wide range of buildings. is given to lifeline buildings such as
field of geotechnical came to Indonesia
In the case of very tall structures, it hospitals, fire stations and water engineering for both with Rio Tinto from
is recommended that detailed site supply. Very high priority is given consulting engineers Australia for the
and geotechnical development of KPC
specific studies are carried out based to power stations, as well as areas specialists before Coal and has been
on the precise location of the proposed needed for refuge for personnel joining Tensar active in Indonesia
International in 1991. for over 25 years
building. in cases of a large magnitude Mike has worked in in a variety of
earthquake. Secondary levels of Asia Pacific for a total senior engineering
The code has reinforced some importance are assigned to structures of 25 years, moving to management and
Jakarta in 1993. director level roles.
previous design recommendations – such as schools, cinemas, churches
for example the principle of building and mosques.
columns being stronger than their works, roads, embankments, water
beams which helps to prevent Kalimantan remains the only area resources structures, wharves and
buildings from collapsing, as well with generally low requirements for bridges, etc. It has been suggested
as the details and form of the steel earthquake design, although the areas this will be the next objective of the
reinforcement used in the columns along the east coast have now been Earthquake Study group at ITB.
and beams. The photographs above given a low level seismic ranking.
illustrate what can happen when Returning to the conclusion of the
these principles are not followed, The revised code is for the design February 2012 UP.DATE article, what
based on damage observed following of buildings, and does not address does the new seismic design code
the 2009 Padang earthquake. The earthquake requirements for civil SNI 1726:2012 imply for existing
buildings in Jakarta, which were
designed to the previous code?
ONE OF THE SEISMIC HAZARD MAPS PUBLISHED IN THE NEW SNI 1726:2012 There is no one single answer to
SEISMIC CODE
this question. Design requirements
have changed, and have been
brought into line with the most up-
to-date knowledge and practice,
accumulated over the last 10 years.
Depending on the type of building
and its location, seismic design
requirements may well have become
more onerous, most probably for
taller buildings. If building owners or
users are concerned, then it would be
wise to seek expert advice, in order
to check or re-assess their property
in the light of the new seismic design
code.