Model: Frequency: Fuel Type: C17 D5 (X-Series) 50 HZ Diesel: Generator Set Data Sheet
Model: Frequency: Fuel Type: C17 D5 (X-Series) 50 HZ Diesel: Generator Set Data Sheet
Standby Prime
Fuel consumption kVA (kW) kVA (kW)
Ratings 16.5 (13.2) 15 (12)
Load 1/4 1/2 3/4 Full 1/4 1/2 3/4 Full
gph 0.6 0.8 1.0 1.2 0.6 0.7 0.9 1.1
L/hr 2.3 3.0 3.7 4.6 2.2 2.8 3.4 4.3
Standby Prime
Engine rating rating
Engine manufacturer Cummins
Engine model X2.5G2
Configuration 4 cycle, in-line, 3 cylinder diesel
Aspiration Naturally aspirated
Gross engine power output, kWm 27 24.37
BMEP at set rated load, kPa 863.9 779.8
Bore, mm 91.4
Stroke, mm 127
Rated speed, rpm 1500
Piston speed, m/s 6.35
Compression ratio 18.5:1
Lube oil capacity, L 7.3
Overspeed limit, rpm 1725
Regenerative power, kW 2
Governor type Mechanical - Std
Starting voltage 12 Volts DC
Fuel flow
Maximum fuel flow, L/hr 40
Maximum fuel inlet restriction, mm Hg 73.66
Maximum fuel inlet temperature, °C 60
cumminspower.com
©2014 Cummins Power Generation Inc. | DS338-CPGK-RevF (6/14)
Standby Prime
Air rating rating
Combustion air, m3/min 2.30 2.30
Maximum air cleaner restriction, kPa 4
Exhaust
Exhaust gas flow at set rated load, m3/min
Exhaust gas temperature, °C 660 660
Maximum exhaust back pressure, kPa 3.38
Genset outline
Open set
Enclosed set
Outlines are for illustrative purposes only. Please refer to the genset outline drawing for an exact representation of this model.
cumminspower.com
©2014 Cummins Power Generation Inc. | DS338-CPGK-RevF (6/14)
Alternator data
Connection1 Temp rise ºC Duty2 Alternator Voltage
3 phase 163/125 S/P PI044G 380-416
3 phase 125 /105 S/P PI044H 380-440
1 phase 125/105 S/P PI044H 220-240
Ratings definitions
Emergency standby power Limited-time running power Base load (continuous)
(ESP): (LTP): Prime power (PRP): power (COP):
Applicable for supplying power to Applicable for supplying power Applicable for supplying power Applicable for supplying
varying electrical load for the to a constant electrical load for to varying electrical load for power continuously to a
duration of power interruption of a limited hours. Limited Time unlimited hours. Prime Power constant electrical load for
reliable utility source. Emergency Running Power (LTP) is in (PRP) is in accordance with ISO unlimited hours. Continuous
Standby Power (ESP) is in accordance with ISO 8528. 8528. Ten percent overload Power (COP) is in accordance
accordance with ISO 8528. Fuel capability is available in with ISO 8528, ISO 3046,
Stop power in accordance with accordance with ISO 3046, AS 2789 and DIN 6271.
ISO 3046, AS 2789 and DIN 6271. AS 2789 and DIN 6271.