Wind Load Calculations

This document provides load calculations for a main frame structure. It details the geometry of the truss, as well as dead loads, live loads, and wind loads based on the basic wind speed and pressure coefficients. Wind load diagrams are presented for different wind directions showing the uniform distributed load values.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
228 views3 pages

Wind Load Calculations

This document provides load calculations for a main frame structure. It details the geometry of the truss, as well as dead loads, live loads, and wind loads based on the basic wind speed and pressure coefficients. Wind load diagrams are presented for different wind directions showing the uniform distributed load values.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 3

LOAD CALCULATIONS

Job No. : Rev. No. : R0


Project : Date : 27/04/2019
Clint : Designed by : Sabin
Description : LOADS APPLIED ON THE MAIN FRAME-1 Checked by :
Truss Design

Length (o/o) = 42.67 m


Width (o/o) = 23.60 m
Width module =
Bay spacing = 23.00 m
Clear eave height = 3.96 m
Max. eave height = 4.50 m
Roof slope (θ) = 21.00 ˚
DEAD LOAD (DL)
Wt. of sheet
Dead Load (DL) = 0.15 KN/m²

LIVE LOAD (LL)


Live load/unit area, roof
Live Load (LL) = 0.45 KN/m²

WIND LOAD (WL)


Basic wind speed (Vb) = 47 m/s
Design wind speed (Vz) = Vbxk1xk2xk3
where,
k1 = probability factor (risk coefficient)
= 1 Terrain Category Class
k2 = terrain, height and structure size factor 2 B
= 0.98
k3 = topography factor
= 1
Vz = 46.06 m/s

Design wind pressure (pz) = 0.6xVz²


pz = 1.273 KN/m²

PRESURE COEFFICIENTS:~
Encloser condition of the building = Enclosed
Internal pressure coeff.(Cpi) = 0.20

h/w = 0.19
= h/w<=1/2
l/w = 1.81
= 3/2<=l/w<4
External pressure coeff.(Cpe) : Table 5
Wind Angle Coeff. For Roof
(ө)
Left Right
0 degree -0.82 -0.59
90 degree -0.80 -0.79

(Cpe-Cpi) =

Wind Angle takin +cpi takin -cpi


(ө)
Left Right Left Right
0 degree -1.0200 -0.79 -0.6200 -0.3900
90 degree -1.00 -0.99 -0.6000 -0.5900

So, take (Cpe-Cpi) = -1.0200

Design Force on roof (F)


F = -1.298 KN/m²

WIND LOAD DIAGRAMS:~

Wind Across the Ridge (With -Ve Cpi) Wind Across the Ridge (With +Ve Cpi)
KN/m
-0.62 -18.15KN/m -0.39 -11.42
KN/m -1.02 -29.863KN/m -0.79 -23.13

KN/m KN/m KN/m KN/m


#REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF!
Wind Parallel to Ridge(With +Ve Cpi)
-1.00 -29.28KN/m -0.99 -28.98 KN/m

KN/m KN/m
#REF! #REF!
#REF! #REF!

Wind Parallel to Ridge(With -Ve Cpi)


-0.60 -17.57KN/m -0.59 -17.27 KN/m

KN/m KN/m
#REF! #REF!
#REF! #REF!
Note:
1) Values within the circles are the UDL
2) -Ve value means, load applied
away from structure.
Terrain Category Class
1 A
2 B
3 C

0.0
Enclosed 0.2
Partially Enclosed 0.5
Open 0.7

DEGREE CO-EFF
20 -0.8 21.00 -0.82
0 degree 30 -1
20 -0.6 21.00 -0.59
30 -0.5
20 -0.8 21.00 -0.8
90 degree 30 -0.8
20 -0.8 21.00 -0.79
30 -0.7