Advance Sensorless Vector Control Function
Advance Sensorless Vector Control Function
N50
Global products
· CE and UL/cUL directive compliance (0.4~3.7kW)
· Observe EN standard by attaching EMC filter
200V CLASS
N100 N100 N100
Item(N100) -004 -007 -015
SF SF SF
Applicable
Motor 0.4 0.75 1.5
Capacity(kW)
Rated Output
3.0 5.0 7.0
Current(A)
Output Rated Output
1.1 1.9 3.0
Capacity(kVA)
Rated Output
3-phase, 200~230V(±10%)
Voltage(V)
Maximum
Output 400Hz
Frequency(Hz)
Input Power 1Ø, 200~230Vac, 50/60Hz
Protective
IP20
Structure
PWM method Space vector PWM control
Cooling
Self cooling Forced cooling
Method
Torque
V/F control, sensorless vector control
Control
Output
Frequency 0.01~400Hz
Range
Frequency Max. setting frequency/500 (DC 5V input),
Analog
Setting Max. setting frequency/1000 (DC 10V,4~20mA input)
Resolution Digital 0.01Hz (100Hz less), 0.1Hz (100Hz or more)
Analog Within 0.1% of output frequency
Frequency
Digi
Precision Within 0.01% of maximum output frequency
tal
Voltage/
Frequency Any base frequency setting possible between 0.5 Hz and 400 Hz
Characteristic
Overload
150% of rated current for 60 sec.
Rating
Starting
Control More than 200% (at 0.5Hz)
Torque
Chara-
Torque
cteristic Manual torque boost can be set between 0~50%
Boost
Acceleration/
Deceleration 0.1~3000 sec. setting possible
Time Setting
Acceleration/
Deceleration Linear, S-curve, U-curve selection possible
Pattern
Regene
150%(5 sec.)
rative
Braking
Operating frequency(0~10Hz), operating time(0~10 sec.), operating voltage(0~50%)
Torque
DC Braking variable
External DC braking setting possible
Current stall
Prevention Operation current level setting possible(0~200% variable), enable/disable selection
Operation Level
Voltage Stall
Prevention Operation level constant, enable/disable selection
Operation Level
Input Fre Analog 0 to 5V DC, 0 to 10V DC, 4 to 20mA,
Signals que External variable resistor(1~2㏀, 1W), main unit volume resistor input from control panel
ncy
Set Digital Control panel
ting
Starting
Individual selection of forward or reverse run
Signal
Abnormality
Used to reset protective state provided when protective function is activated
Reset
Multispeed
16-step speeds settable(each speed can be set between 0Hz and 400Hz)
Selection
2nd Function Acceleration/deceleration time, base frequency, maximum frequency, multistage frequency,
Selection torque boost, electronic thermal, control method, motor parameter
Protective
Overcurrent cutoff, regenerative overvoltage cutoff, undervoltage, output short circuit,
and
temperature abnormality, overload cutoff (electronic thermal)
Warning Functions
Environ- Ambient
ment Temperature /
-10℃~40℃ (no freezing) / -20℃~60℃
Storage
Temperature
Ambient Humidity / 90%RH or less(no condensing) / Indoors (no corrosive gases, no flammable gases, no oil mist
Installation Area and no dust)
Altitude and Vibration Maximum 1000m or less above sea level, 5.9㎨
International Directive CE, UL/cUL directive compliance
N100-015 N100-022
Item(N100)
LF LF
Output Applicable
Motor 1.5 2.2
Capacity(kW)
Rated Output
7.0 11.0
Current(A)
Rated Output
3.0 4.2
Capacity(kVA)
Rated Output
3-phase, 200~230V(±10%)
Voltage(V)
Maximum
Output 400Hz
Frequency(Hz)
Input Power 3Ø, 200~230Vac, 50/60Hz
Protective
IP20
Structure
PWM method Space vector PWM control
Control Cooling Forced cooling
Deceleration
Pattern
Re-
150% (5 sec.)
generative
Braking Torque Operating frequency(0~110Hz), operating time(0~10 sec.), operating
DC Braking voltage(0~50%) variable
External DC braking setting possible
Current Stall Prevention
Operation current level setting possible(0~200% variable), enable/disable selection
Operation Level
Voltage Stall Prevention
Operation level constant, enable/disable selection
Operation Level
Fre 0 to 5VDC, 0 to 10VDC, 4 to 20mA, External variable resistor(1~2
Analog
quency unit volume resistor input from control panel
Setting Digital Control panel
Starting Signal Individual selection of forward or reverse run
Abnormality
Used to reset protective state provided when protective function is activated
Reset
Input
Signal
Multispeed Selection 16-step speeds settable(each speed can be set between 0Hz and 400Hz)
Operation
Inverter running, frequency reached, frequency detection, overload warning fault
Output Signals Status
For Meter Output frequency, output current, output voltage
Operation Output frequency, output current, output voltage, operation direction, PID
Displayed on Status feedback, terminal input, terminal output
Display Function
Control Panel
Error Details Fault list, fault history