0% found this document useful (0 votes)
73 views

Advance Sensorless Vector Control Function

This document provides information on LV and MV inverters, including: 1) Key features of the inverters such as advance sensorless vector control, strengthened auto-tuning and PID control functions, and realizing tripless driving through current suppression. 2) Global compliance certifications and optional accessories. 3) Technical specifications for the N100 series inverters, including applicable motor capacity, output current and voltage, frequency range, control characteristics, protective functions, and environmental specifications.

Uploaded by

Neda Aleksandrov
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
73 views

Advance Sensorless Vector Control Function

This document provides information on LV and MV inverters, including: 1) Key features of the inverters such as advance sensorless vector control, strengthened auto-tuning and PID control functions, and realizing tripless driving through current suppression. 2) Global compliance certifications and optional accessories. 3) Technical specifications for the N100 series inverters, including applicable motor capacity, output current and voltage, frequency range, control characteristics, protective functions, and environmental specifications.

Uploaded by

Neda Aleksandrov
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 7

 

   

    LV Inverter  Catalog

        N100    Certificat


e
        N300
 Manual
        N300-P  

        N500 / N500-P

        N50

    MV Inverter Advance sensorless vector control function


· Realize smooth driving without motor vibration and high precise driving not concerned
with changing load
· High starting torque of 200% at 0.5Hz

Strengthening auto-tuning function


· Automatically measure motor parameters.
· Realize optimal motor control without torque dropping and speed fluctuation.
· Realize precise driving without inconvenience of user measures motor parameters
manually

Strengthening the PID control function


· Strengthening the speed control program for controlling flux, temperature, pressure
and so forth.
· Apply to high precision systems by high speed responsibility.

Realize tripless driving by adding current suppression


· Realize stable driving at instant impact load and overload by adding over-current level
adjusting function
· Maintain constant speed on changing load suddenly by rapidity speed restoration
characteristics
· Widely apply transfer machine, treadmill, industrial washing machine and so forth by
momentary current suppressing

Global products
· CE and UL/cUL directive compliance (0.4~3.7kW)
· Observe EN standard by attaching EMC filter

Develop option product for user convenience


· Digital Operator(DOP1 / operation and display)
· Remote Operator(NOP100 / read and copy function)
· EMI/EMC filter by EN standard(NHF-2020, NHF-4012)

 
200V CLASS
N100 N100 N100
Item(N100) -004 -007 -015
SF SF SF
Applicable 
Motor  0.4 0.75 1.5
Capacity(kW)
Rated Output 
3.0 5.0 7.0
Current(A)
Output Rated Output 
1.1 1.9 3.0
Capacity(kVA)
Rated Output 
3-phase, 200~230V(±10%)
Voltage(V)
Maximum 
Output  400Hz
Frequency(Hz)
Input Power 1Ø, 200~230Vac, 50/60Hz
Protective 
IP20
Structure
PWM method Space vector PWM control
Cooling 
Self cooling Forced cooling
Method
Torque 
V/F control, sensorless vector control     
Control
Output 
Frequency  0.01~400Hz
Range
Frequency  Max. setting frequency/500 (DC 5V input), 
Analog
Setting  Max. setting frequency/1000 (DC 10V,4~20mA input)
Resolution Digital 0.01Hz (100Hz less), 0.1Hz (100Hz or more)   
Analog Within 0.1% of output frequency
Frequency
Digi
Precision Within 0.01% of maximum output frequency   
tal
Voltage/
Frequency  Any base frequency setting possible between 0.5 Hz and 400 Hz
Characteristic
Overload 
150% of rated current for 60 sec.
Rating 
Starting 
Control More than 200% (at 0.5Hz)
Torque
Chara-
Torque 
cteristic Manual torque boost can be set between 0~50%
Boost
Acceleration/
Deceleration  0.1~3000 sec. setting possible
Time Setting
Acceleration/
Deceleration  Linear, S-curve, U-curve selection possible
Pattern
Regene
150%(5 sec.)
rative
Braking 
Operating frequency(0~10Hz), operating time(0~10 sec.), operating voltage(0~50%)
Torque
DC Braking variable 
External DC braking setting possible

Current stall 
Prevention  Operation current level setting possible(0~200% variable), enable/disable selection
Operation Level
Voltage Stall 
Prevention  Operation level constant, enable/disable selection
Operation Level
Input Fre Analog 0 to 5V DC, 0 to 10V DC, 4 to 20mA, 
Signals que External variable resistor(1~2㏀, 1W), main unit volume resistor input from control panel
ncy 
Set Digital Control panel
ting
Starting 
Individual selection of forward or reverse run
Signal
Abnormality 
Used to reset protective state provided when protective function is activated
Reset
Multispeed 
16-step speeds settable(each speed can be set between 0Hz and 400Hz)
Selection
2nd Function  Acceleration/deceleration time, base frequency, maximum frequency, multistage frequency,
Selection torque boost, electronic thermal, control method, motor parameter

Multispeed operation, operation mode selection, DC braking, upper/lower frequency setting,


Operation  frequency jump operation, PID control, AVR, 2-stage accel./decel., instantaneous power
Functions failure restart operation, electronic thermal, software lock, carrier frequency adjustment, auto
tuning function, forward/reverse run prevention, RS485 link operation
Out Operation 
Inverter running, frequency reached, frequency detection, overload warning fault
put  Status
Sig For Meter Output frequency, output current, output voltage
Display nals
Displayed  Operation Output frequency, output current, output voltage, operation direction, PID feedback, terminal
Function on  Status input, terminal output
Control  Error  Fault list, fault history
Panel Details

Protective 
Overcurrent cutoff, regenerative overvoltage cutoff, undervoltage, output short circuit,
and 
temperature abnormality, overload cutoff (electronic thermal)
Warning Functions
Environ- Ambient 
ment Temperature / 
-10℃~40℃ (no freezing) / -20℃~60℃
Storage 
Temperature 
Ambient Humidity /  90%RH or less(no condensing) / Indoors (no corrosive gases, no flammable gases, no oil mist
Installation Area and no dust)
Altitude and Vibration  Maximum 1000m or less above sea level, 5.9㎨
International Directive  CE, UL/cUL directive compliance

N100-015  N100-022 
Item(N100)
LF LF
Output Applicable 
Motor  1.5 2.2
Capacity(kW)
Rated Output 
7.0 11.0
Current(A)
Rated Output 
3.0 4.2
Capacity(kVA)
Rated Output 
3-phase, 200~230V(±10%)
Voltage(V)
Maximum 
Output  400Hz
Frequency(Hz)
Input Power 3Ø, 200~230Vac, 50/60Hz
Protective 
IP20
Structure
PWM method Space vector PWM control
Control Cooling  Forced cooling
Deceleration 
Pattern
Re-
150% (5 sec.)
generative
Braking Torque Operating frequency(0~110Hz), operating time(0~10 sec.), operating
DC Braking voltage(0~50%) variable
External DC braking setting possible
Current Stall Prevention
Operation current level setting possible(0~200% variable), enable/disable selection
Operation Level
Voltage Stall Prevention
Operation level constant, enable/disable selection
Operation Level
Fre 0 to 5VDC, 0 to 10VDC, 4 to 20mA, External variable resistor(1~2
Analog
quency unit volume resistor input from control panel
Setting Digital Control panel
Starting Signal Individual selection of forward or reverse run
Abnormality 
Used to reset protective state provided when protective function is activated
Reset

Input
Signal

Multispeed Selection 16-step speeds settable(each speed can be set between 0Hz and 400Hz)

Multispeed operation, operation mode selection, DC braking, upper/lower frequency


setting, frequency jump operation, PID control, AVR, 2-stage accel./decel.,
Operation Functions
instantaneous power failure restart operation, electronic thermal, software lock,
carrier frequen

Operation
Inverter running, frequency reached, frequency detection, overload warning fault
Output Signals Status
For Meter Output frequency, output current, output voltage
Operation Output frequency, output current, output voltage, operation direction, PID
Displayed on Status feedback, terminal input, terminal output
Display Function
Control Panel
Error Details Fault list, fault history

Overcurrent cutoff, regenerative overvoltage cutoff, undervoltage, output short


Protective and Warning Functions
circuit, temperature abnormality, overload cutoff (electronic thermal)

Ambient Temperature / Storage


-10℃~40℃ (no freezing) / -20℃~60℃
Temperature
Environment Ambient Humidity / Installation 90%RH or less(no condensing) / Indoors (no corrosive gases, no flammable gases,
Area no oil mist and no dust)
Altitude and Vibration Maximum 1000m or less above sea level, 5.9
International Directive CE, UL/cUL directive compliance

Transformer | High Voltage Circuit Breaker | Switchgear | Medium & Low Voltage Circuit Breaker | Rotating


Machinery | Power Electronics | 
Control & System Intergration | Marine Purpose Equipment | Traction Power Supply and Propulsion System | Turnkey
Solution | Solar Power System | Wind Turbine System

You might also like