Data Sheet DS/FER200/FEF200/FEV200–EN Rev.

AquaMaster3
Electromagnetic flowmeter

The high value, precision


solution for remote water
metering and
irrigation applications

Full range of power supply options for lowest cost site Peace of mind with class leading, fully potted, IP68
preparation and energy usage electronic package
— AC mains — zero water ingress, even during flood conditions
— external long-life battery pack — military specification IP68 plug and socket connections
— internal standard lithium D-cell battery — sealed-for-life = zero maintenance
— solar / wind-power
Compatible with ABB's full range of industry-leading flow
Optional built in multi-sampling rate, pressure and flow sensors
data logger — reduced-bore series for high turn-down applications, for
— integrated, all-in-one solution example, leakage detection
— high resolution flow and pressure data logger — full-bore series for general-purpose water metering and
— three instruments for the price of one – no need to purchase irrigation applications
a separate pressure transmitter or data logger — all sensors are buriable, eliminating the need for costly
chamber construction – a significant site preparation saving
Wireless communication via optional built in GSM modem
— access and download all logged data remotely Full range of approvals
— remote diagnostics — optional MID approval
— reduces the requirement for costly and time-consuming site — optional OIML R049 approval
visits — NMI approval pending

Fully self-contained or remote transmitter


— integral sensor / transmitter option
— remote transmitter option, where sensor is required to be
buried for example
AquaMaster3
Electromagnetic flowmeter

The Company Flow performance


ABB is an established world force in the design and With the widest flow range, optimum accuracy and long term
manufacture of instrumentation for industrial process control, stable calibration, the reduced-bore (FER) performance is OIML
flow measurement, gas and liquid analysis and environmental R49 type approved (DN40 to DN300) to the latest Class 1 and
applications. As a world leader in process automation Class 2 accuracies. This low flow rate capability enables minimal
technology our worldwide presence, comprehensive service and night flow rates to be metered; particularly important for leakage
application oriented know-how make ABB a leading supplier of management, bulk revenue and district metering applications.
flow measurement products. The clear bore of the AquaMaster3 eliminates the possibility of
damage by particulate matter and the absence of moving and
Introduction wearing components ensures that this unique level of
performance is maintained long term. Accuracy as standard
Setting the standard for the potable Water Industry (±0.25 % Mains powered) or (±0.50% battery powered) in both
AquaMaster3, available in sizes 15 to 600 mm (1/2 to 24 in.) with forward and reverse flow directions.
a reduced-bore construction, it is the total solution for flow
measurement in the potable water industry. Outstanding Easy and quick commissioning
performance, innovative features and user benefits, coupled 'Fit-and-Flow' data storage inside AquaMaster eliminates the
with low cost-of-ownership ensures that AquaMaster3 is the need to match sensor and transmitter in the field. On initial
first choice for Leakage Management, District Metering, Bulk installation, the self-configuration sequence automatically
Revenue and Trunk Mains applications. replicates into the transmitter all calibration factors, meter
size and serial numbers, as well as customer site-specific
CalMaster2 – the verification tool settings, eliminating the opportunity for error
CalMaster2 is a suite of stand-alone field verification tools, that
enables users to test the integrity of the AquaMaster flow meter Logged data storage
system. An easy to use external verification device, coupled with The AquaMaster3 transmitter can contain an optional
fingerprinting technology, to determine the accuracy status of multi-speed, multi-channel, dual-variable logger. The ability of
the AquaMaster flowmeter to within ±1 % of its original factory the logger to run at two speeds simultaneously enables the user
calibration. CalMaster2 also supports printing of calibration to investigate, in precise detail, flow and pressure activity during
verification records for regulatory compliance. a period of interest. AquaMaster3 eliminates such quantization
effects, averaging digitally over the selected logging interval.
Such high resolution data facilitates allow step testing, leakage
detection and water network analysis.

Universal transmitter – powerful and flexible


AquaMaster3 design of mains, renewable energy and
battery-powered transmitter. It has a stainless steel housing with
a thermoplastic outer and the assembly is sealed-for-life to IP68
as standard. The transmitter incorporates military specification
plug & socket connections for all inputs and outputs. The
transmitter can be mounted integral with the AquaMaster
sensor (integral mount) or remotely from the AquaMaster sensor
(remote) to enable the sensor to be buried for example. For
integral sensors, the mounting system positions the display so
that it is visible from both the top and the side.

Assured quality
AquaMaster is designed and manufactured in accordance with
international quality procedures (ISO 9001) and all flowmeters
are calibrated on nationally-traceable calibration rigs to provide
Remote communications the end-user with complete assurance of both quality and
AquaMaster3 has the added built in capability of a Quad Band performance of the meter.
GSM/SMS engine. This allows the user to be able to interrogate
the flowmeter data remotely or have it sent direct to a host
server. Flow data is recorded typically every 15 minutes and sent
via SMS message to your server automatically, every day – and
it's fast, easy and convenient. Pressure data is optionally sent in
a separate message. Thousands of meters can be managed
using this solution, which will run your whole network from one
server.

2 DS/FER200/FEF200/FEV200–EN Rev. H
AquaMaster3
Electromagnetic flowmeter

AquaMaster – always the first choice Fit and Flow


AquaMaster sets the standard for the potable water industry.  No need to match sensor and transmitter, sensor stores
The specification, features and user benefits offered by this all calibration factors, site settings and serial numbers
range are based on ABB's worldwide experience in this industry  Bi-directional flow
and they are all targeted specifically to the industry's
 Flow, pressure and logger in one
requirements.
 Fast, reliable installation, rated IP68 (NEMA 6P) for
Submersible and buriable submerged use in flooded chambers
AquaMaster sensors have a rugged, robust construction to  Volume totalizer and tariff values backed-up in sensor for
ensure a long, maintenance-free life under the arduous total security, tamper-resistant and MID approved
conditions experienced in the potable Water Industry. The  Multiple, programmable password levels stored for
sensors are, as standard, inherently submersible (IP68, NEMA measurement security
6P), thus ensuring suitability for installation in chambers and
metering pits which are liable to flooding.  Comprehensive display, 8 mm (0.31 in.) high displays for
totals (exceeds ISO 4064 requirements)
A unique feature of the AquaMaster sensors is that sizes DN40
 Resettable or secure totals
to DN600 are buriable; installation merely involves excavating to
the underground pipe, fitting the sensor, cabling back to the  All connections via military specification plug and socket
transmitter and then backfilling the hole.  3 outputs (forward and reverse pulse, or pulses, direction
and alarm)
Overview of the AquaMaster
A wide range of features and user benefits are built into Remote access via mobile phone technology
AquaMaster as standard:  Remote access to logger data over quad-band GSM
network by SMS text message
Solar and wind power  Remote configuration, status monitoring and preventive
Utilizes a simple DC (6 to 22 V) connection from sources as maintenance also via standard GSM mobile phones
small as a 5 W solar panel / wind generator. Wind generators  Automated metering and alarm reporting via SMS text
and solar panels are not supplied by ABB.
Typical applications
Mains power with super capacitor back-up  Leakage management and non revenue water
 Mains-only option supplied with a built-in rechargeable
 Bulk revenue metering
super capacitor backup power source
 District metering and Zonal networks
 The super capacitor can operate for up to 5 days without
power (depending on operating conditions)  Distribution and trunk main metering
 In the event of mains interruption, continuous  Irrigation and abstraction
measurement is maintained and alarms reported via SMS
protocols for up to 5 days without power

External battery power for remote locations


 Up to 5-year* battery life (one SMS message per day)
 Manganese alkaline battery pack*
 Site-replaceable battery pack
 The battery can be replaced without loss of logger
contents enabling smooth switchover

Internal battery power, using standard lithium D-cells,


for remote locations
 Readily-available, locally sourced, D-cell lithium batteries
 6 years continuous operation*
 Totally sealed, IP68 integrated package
 Tamper-proof, anti-vandal, engineered solution –
no exposed cables that can be cut
 Suitable for higher ambient temperature locations

DS/FER200/FEF200/FEV200–EN Rev. H 3
AquaMaster3
Electromagnetic flowmeter

OIML / MID approved Superior control through advanced sensor


With the widest flow range, optimum accuracy and long term design
stable calibration, AquaMaster3 sets new performance The innovative, reduced-bore sensor design improves flow
standards in the water industry. The performance is OIML R49 profile and reduces up- and down-stream piping requirements
type approved (DN40 to DN300) to the latest Class 1 and Class for the most commonly used sizes of 40 to 300 mm (11/2 to
2 accuracies with a tighter accuracy above Q 0.5 % and Q 12 in.). This reduced-bore meter allows for very impressive
0.25 %. results in the most difficult of installation requirements. This
This low flow rate capability enables previously unrecordable range of sensor allows the user to reduce the required Upstream
minimal night flow rates to be metered; particularly important for and Downstream pipe requirements to 0 x DN Up and 0 x DN
bulk revenue and district metering applications. The unrestricted Down.
bore of the AquaMaster3 eliminates the possibility of damage by The content below is the extract from OIML R49 test
particulate matter and the absence of moving and wearing requirements:
components ensures that this unique level of performance is
6.8 Flow disturbance tests (R 49-1, 5.3.4)
maintained long term.
6.8.1 Object of tests
The unique design of the AquaMaster3 reduced-bore sensor
To verify that the meter complies with the requirements of 5.3.4 in R
conditions the flow profile in the measuring section so that
49-1 for forward flow and where appropriate for reverse flow (see R
distortions in the flow profile, either upstream or downstream, 49-1, 3.2.5).
are flattened. The result is excellent in situ meter performance,
even with very bad hydraulic installation conditions. Hydraulic Note 1: The effects on the error (of indication) of a water meter of the
presence of specified, common types of disturbed flow upstream and
disturbance tests conducted during OIML R49 type approval
downstream of the meter are measured.
confirmed a guaranteed accuracy to Class 1 and Class 2, even
with flow disturbers bolted directly on the meter, either upstream
or downstream at zero pipe diameters. AquaMaster3
reduced-bore version has been type examined and conforms to
EU Measuring Instrument Directive (MID).
The approval is for:
0 x DN 0 x DN
 Class 1 and Class 2 accuracy (calibration option)
 Environmental class T50 for water temperatures of
0.1 to 50 °C (32.18 to 122 °F) Recommended upstream / downstream conditions

 Electromagnetic Environment E2 (10 V/m) Note 2: Types 1 and 2 disturbance devices are used in the tests to
create left-handed (sinistrorsal) and right-handed (dextrorsal), rotational
 Any pipe orientation velocity fields (swirl), respectively. The flow disturbance is of a type
 0 Diameters upstream pipe usually found downstream of two 90° bends directly connected at right
angles. A type 3 disturbance device creates an asymmetric velocity
 0 Diameters downstream pipe profile usually found downstream of a protruding pipe joint, single bend,
or a gate valve not fully opened.
 Integral or remote transmitter (<200 m [<656 ft.] cable)
 DN40 to DN300 (11/2 to 12 in. NB), bi-directional flow

The OIML R49-1 certificate of conformity is available from:


http://www.abb.com/product/seitp330/86a2f24a4eab24c9c12
577fb004f57fe.aspx
AquaMaster is also approved under the EU Measuring
Instruments Directive (MID) 2004/22/EC, that covers putting into
use water flowmeters for certain applications. MID AquaMaster3
is secured against tamping and is available as an option, along
with fingerprinting for CalMaster2 in situ verification product,
with certificate printout to ±1 % accuracy.
AquaMaster certificates of EC type-examination of a measuring
instrument are available from:
http://www.abb.com/product/seitp330/86a2f24a4eab24c9c12
577fb004f57fe.aspx

4 DS/FER200/FEF200/FEV200–EN Rev. H
AquaMaster3
Electromagnetic flowmeter

Specification
AquaMaster3 specification to OIML R49 Class 1

6
AquaMaster3 accuracy specification
(DN100 – battery / renewable energy powered) AquaMaster3 Class 1

4 AquaMaster NMI

OIML Class 1 Limit

NMI M10 Limit


Error (%)

0
0.1 1.0 10.0 100.0 1000.0

–2

–4

Class 1 Q1 Q2 Q0.5 % Q3 Q4
–6
Flowrate (m3 / h)

AquaMaster3 specification to OIML R49 Class 1 and NMI M10

AquaMaster3 specification to OIML R49 Class 2

6
AquaMaster3 accuracy specification
(DN100 – battery / renewable energy powered)
AquaMaster3 Class 2
4 AquaMaster NMI

2
OIML Class 2 Limit

NMI M10 Limit


Error (%)

0
0.1 1.0 10.0 100.0 1000.0

–2

–4

Class 2 Q1 Q2 Q0.5 % Q3 Q4
–6
Flowrate (m3 / h)

AquaMaster3 specification to OIML R49 Class 2 and NMI M10

DS/FER200/FEF200/FEV200–EN Rev. H 5
AquaMaster3
Electromagnetic flowmeter

Battery- or renewable energy-powered reduced-bore meters (FER) – flow specifications


Class 2 specification Class 1 specification
Size Q4 Q3 Q(0.5%) Q2 Q1 Q2 Q1
m3 / h m3 / h m3 / h m3 / h m3 / h R m3 / h m3 / h R
mm in.
(Ugal / min) (Ugal / min) (Ugal / min) (Ugal / min) (Ugal / min) (Ugal / min) (Ugal / min)
1
15 /2 5.0 (22.01) 4.0 (17.61) 0.24 (1.05) 0.026 (0.110) 0.016 (0.070) 250 0.04 (0.176) 0.025 (0.11) 160
20 3
/4 7.9 (34.8) 6.3 (27.74) 0.37 (1.62) 0.04 (0.176) 0.025 (0.110) 250 0.063 (0.277) 0.04 (0.176) 160
25 1 12.5 (55) 10 (44) 0.6 (2.64) 0.064 (0.281) 0.04 (0.176) 250 0.1 (0.44) 0.063 (0.277) 160
40* 11/2 31 (138) 25 (110) 1.5 (6.6) 0.16 (0.704) 0.1 (0.44) 250 0.25 (1.10) 0.16 (0.704) 160
50* 2 50 (220) 40 (176) 2.4 (10.56) 0.26 (1.14) 0.16 (0.70) 250 0.4 (1.76) 0.25 (1.10) 160
65 21/2 79 (347) 63 (277) 3.7 (16.29) 0.40 (1.76) 0.25 (1.10) 250 0.63 (2.77) 0.4 (1.76) 160
80* 3 125 (550) 100 (440) 5.9 (25.97) 0.64 (2.82) 0.4 (1.76) 250 1.0 (4.40) 0.63 (2.77) 160
100* 4 200 (880) 160 (704) 9.4 (41.38) 1.0 (4.4) 0.64 (2.82) 250 1.6 (7.04) 1.0 (4.40) 160
125 5 200 (880) 160 (704) 9.4 (41.38) 1.0 (4.4) 0.64 (2.82) 250 1.6 (7.04) 1.0 (4.40) 160
150* 6 500 (2200) 400 (1760) 23.5 (103.46) 2.56 (11.27) 1.6 (7.04) 250 4.0 (17.61) 2.5 (11.01) 160
200* 8 788 (3470) 630 (2770) 37 (162.90) 4.0 (17.61) 2.5 (11.01) 250 6.3 (27.74) 3.9 (17.17) 160
250* 10 1250 (5500) 1000 (4400) 60 (260) 6.4 (28.18) 4.0 (17.61) 250 10 (44) 6.3 (27.74) 160
300* 12 2000 (8810) 1600 (7045) 90 (400) 10.2 (44.91) 6.4 (28.18) 250 16 (70.44) 10 (44) 160
350 14 2000 (8810) 1600 (7045) 110 (484.3) 16 (70.44) 10 (44.02) 160 41 (180.5) 25 (110) 63
375 15 2000 (8810) 1600 (7045) 110 (484.3) 16 (70.44) 10 (44.02) 160 41 (180.5) 25 (110) 63
400 16 3125 (13760) 2500 (11007) 170 (750) 25 (110) 15.6 (68.68) 160 63 (277.4) 40 (176) 63
450 18 3125 (13760) 2500 (11007) 170 (750) 25 (110) 15.6 (68.68) 160 63 (277.4) 40 (176) 63
500 20 5000 (22014) 4000 (17610) 270 (1190) 40 (176) 25 (110) 160 100 (440) 63.5 (279) 63
600 24 7875 (34670) 6300 (27740) 420 (1850) 63 (277) 39 (172) 160 160 (704) 100 (440) 63
* OIML R49 version available to Class 1 and Class 2

Note. OIML R49–1 allows Class 1 only for meters with Q3 100 m3 / h. Meters outside this range were tested to Class 1 accuracy and passed.

Battery- or renewable energy-powered full-bore meters (FEF) – flow specifications


Class 2 specification Class 1 specification
Size Q4 Q3 Q(0.5%) Q2 Q1 Q2 Q1
m3 / h m3 / h m3 / h m3 / h m3 / h R m3 / h m3 / h R
mm in.
(Ugal / min) (Ugal / min) (Ugal / min) (Ugal / min) (Ugal / min) (Ugal / min) (Ugal / min)
250 10 2000 (8810) 1600 (7045) 107 (471) 16 (70.45) 10 (44) 160 26 (114) 16 (70.45) 100
300 12 3125 (13760) 2500 (11007) 167 (735) 25 (110) 15.6 (68.68) 160 40 (176) 25 (110) 100
350 14 5000 (22014) 4000 (17610) 267 (1175) 40 (176) 25 (110) 160 64 (282) 40 (176) 100
375 15 5000 (22014) 4000 (17610) 267 (1175) 40 (176) 25 (110) 160 64 (282) 40 (176) 100
400 16 5000 (22014) 4000 (17610) 267 (1175) 40 (176) 25 (110) 160 64 (282) 40 (176) 100
450 18 7875 (34670) 6300 (27740) 420 (1850) 63 (277) 39 (172) 160 101 (445) 63 (277) 100
500 20 7875 (34670) 6300 (27740) 420 (1850) 63 (277) 39 (172) 160 101 (445) 63 (277) 100
600 24 12500 (55030) 10000 (44030) 667 (2937) 100 (440) 63 (277) 160 160 (704) 100 (440) 100

Battery- or renewable energy-powered optimized full-bore meters (FEV) – flow specifications


Class 2 specification Class 1 specification NMI M10 Class 2.5
Size Q4 Q3 Q(0.5%) Q2 Q1 Q2 Q1 R Q1
m3 / h m3 / h m3 / h m3 / h m3 / h R m3 / h m3 / h m3 / h R
mm in.
(Ugal / min) (Ugal / min) (Ugal / min) (Ugal / min) (Ugal / min) (Ugal / min) (Ugal / min) (Ugal / min)
40 11/2 50 (220) 40 (176) 2.7 (11.89) 0.4 (1.76) 0.25 (1.10) 160 0.64 (2.82) 0.4 (1.76) 100 0.32 (1.41) 125
50 2 79 (347) 63 (277) 4.2 (18.5) 0.63 (2.77) 0.39 (1.72) 160 1.0 (4.40) 0.63 (2.77) 100 0.50 (2.20) 125
65 21/2 125 (550) 100 (440) 6.7 (29.5) 1.0 (4.40) 0.6 (2.64) 160 1.6 (7.04) 1.0 (4.40) 100
80 3 200 (880) 160 (704) 10.7 (47.11) 1.6 (7.04) 1.0 (4.40) 160 2.6 (11.45) 1.6 (7.04) 100 1.28 (5.64) 125
100 4 313 (1378) 250 (1100) 16.7 (73.53) 2.5 (11.01) 1.6 (7.04) 160 4.0 (17.61) 2.5 (11.01) 100 2.0 (8.81) 125
125 5 313 (1378) 250 (1100) 16.7 (73.53) 2.5 (11.01) 1.6 (7.04) 160 4.0 (17.61) 2.5 (11.01) 100
150 6 788 (3470) 630 (2774) 42 (185) 6.3 (27.74) 3.9 (17.17) 160 10 (44) 6.3 (27.74) 100 5.0 (22.01) 125
200 8 1250 (5504) 1000 (4403) 67 (2985) 10 (44) 6.0 (26.42) 160 16 (70.45) 10 (44) 100 8.0 (35.22) 125

6 DS/FER200/FEF200/FEV200–EN Rev. H
AquaMaster3
Electromagnetic flowmeter

AC-powered reduced-bore meters (FER) – flow specifications


Class 2 specification Class 1 specification
Size Q4 Q3 Q(0.25%) Q2 Q1 R Q2 Q1
m3 / h m3 / h m3 / h m3 / h m3 / h m3 / h m3 / h R
mm in.
(Ugal / min) (Ugal / min) (Ugal / min) (Ugal / min) (Ugal / min) (Ugal / min) (Ugal / min)
1
15 /2 5 (22) 4 (18) 0.11 (0.48) 0.010 (0.044) 0.006 (0.026) 630 0.016 (0.070) 0.010 (0.04) 400
20 3
/4 7.9 (35) 6.3 (27.74) 0.18 (0.79) 0.016 (0.070) 0.010 (0.044) 630 0.025 (0.11) 0.016 (0.070) 400
25 1 12.5 (55) 10 (44) 0.29 (1.27) 0.025 (0.11) 0.016 (0.070) 630 0.04 (0.176) 0.025 (0.11) 400
40* 11/2 31 (138) 25 (110) 1.5 (6.6) 0.063 (0.28) 0.040 (0.176) 630 0.1 (0.44) 0.063 (0.28) 400
50* 2 50 (220) 40 (176) 1.5 (6.6) 0.1 (0.44) 0.063 (0.277) 630 0.16 (0.70) 0.1 (0.44) 400
65 21/2 79 (247) 63 (277) 3 (13.2) 0.16 (0.7) 0.1 (0.44) 630 0.25 (1.10) 0.16 (0.70) 400
80* 3 125 (550) 100 (440) 3 (13.2) 0.3 (1.32) 0.16 (0.70) 630 0.4 (1.76) 0.25 (1.10) 400
100* 4 200 (880) 160 (704) 4.6 (20.25) 0.41 (1.8) 0.25 (1.10) 630 0.64 (2.82) 0.4 (1.76) 400
125 5 200 (880) 160 (704) 4.6 (20.25) 0.41 (1.8) 0.25 (1.10) 630 0.64 (2.82) 0.4 (1.76) 400
150* 6 500 (2200) 400 (1760) 11.4 (50.19) 1.0 (4.40) 0.63 (2.77) 630 1.6 (7.04) 1.0 (4.40) 400
200* 8 788 (3470) 630 (2774) 18 (79.25) 1.6 (7.04) 1.0 (4.40) 630 2.5 (11.01) 1.6 (7.04) 400
250* 10 1250 (5504) 1000 (4400) 29 (127.7) 2.5 (11.01) 1.6 (7.04) 630 4.0 (17.61) 2.5 (11.01) 400
300* 12 2000 (8806) 1600 (7045) 46 (202) 4.1 (18.05) 2.5 (11.01) 630 6.4 (28.18) 4.0 (17.61) 400
350 14 2000 (8806) 1600 (7045) 80 (352) 6.4 (28.18) 4.0 (17.61) 400 12.8 (56.35) 8.0 (35.22) 200
375 15 2000 (8806) 1600 (7045) 80 (352) 6.4 (28.18) 4.0 (17.61) 400 12.8 (56.35) 8.0 (35.22) 200
400 16 3125 (13760) 2500 (11007) 125 (550) 10 (44) 6.3 (27.74) 400 20 (88.06) 12.5 (55.04) 200
450 18 3125 (13760) 2500 (11007) 125 (550) 10 (44) 6.3 (27.74) 400 20 (88.06) 12.5 (55.04) 200
500 20 5000 (22014) 4000 (17610) 200 (880) 16 (70.45) 10 (44) 400 32 (140.9) 20 (88.05) 200
600 24 7875 (34670) 6300 (27740) 315 (1387) 25.2 (110.9) 15.8 (69.56) 400 50.4 (221.9) 31.5 (138.7) 200
* OIML R49 version available to Class 1 and Class 2

Note. OIML R49–1 allow Class 1 only for meters with Q3 100 m3 / h. Meters outside this range were tested to Class 1 accuracy and passed.

AC-powered full-bore meters (FEF) – flow specifications


Class 2 specification Class 1 specification
Size Q4 Q3 Q(0.25%) Q2 Q1 Q2 Q1
m3 / h m3 / h m3 / h m3 / h m3 / h R m3 / h m3 / h R
mm in.
(Ugal / min) (Ugal / min) (Ugal / min) (Ugal / min) (Ugal / min) (Ugal / min) (Ugal / min)
250 10 2000 (8806) 1600 (7045) 160 (704) 8.1 (35.66) 5.1 (22.45) 315 13 (57.24) 8 (35.22) 200
300 12 3125 (13760) 2500 (11007) 250 (1100) 12.7 (55.92) 7.9 (34.78) 315 20 (88.06) 12.5 (55.04) 200
350 14 5000 (22014) 4000 (17610) 400 (1761) 20.3 (89.38) 12.7 (55.92) 315 32 (140.9) 20 (88.06) 200
375 15 5000 (22014) 4000 (17610) 400 (1761) 20.3 (89.38) 12.7 (55.92) 315 32 (140.9) 20 (88.06) 200
400 16 5000 (22014) 4000 (17610) 400 (1761) 20.3 (89.38) 12.7 (55.92) 315 32 (140.9) 20 (88.06) 200
450 18 7875 (34670) 6300 (27740) 630 (2774) 32 (140.9) 20 (88.06) 315 50 (220.1) 32 (140.9) 200
500 20 7875 (34670) 6300 (27740) 630 (2774) 32 (140.9) 20 (88.06) 315 50 (220.1) 32 (140.9) 200
600 24 12500 (55030) 10000 (44030) 1000 (4400) 51 (224.5) 32 (140.9) 315 80 (220.1) 50 (220.1) 200

AC-powered optimized full-bore meters (FEV) – flow specifications


Class 2 specification Class 1 specification NMI M10 Class 2.5
Size Q4 Q3 Q(0.25%) Q2 Q1 R Q2 Q1 R Q1 R
m3 / h m3 / h m3 / h m3 / h m3 / h m3 / h m3 / h m3 / h
mm in.
(Ugal / min) (Ugal / min) (Ugal / min) (Ugal / min) (Ugal / min) (Ugal / min) (Ugal / min) (Ugal / min)
40 11/2 50 (220) 40 (176) 4 (17.61) 0.2 (0.88) 0.13 (0.57) 315 0.32 (1.41) 0.20 (0.88) 200 0.16 (0.70) 250
50 2 79 (348) 63 (277) 6.3 (27.74) 0.32 (1.41) 0.20 (0.88) 315 0.50 (2.20) 0.32 (1.41) 200 0.25 (1.10) 250
65 21/2 125 (550) 100 (440) 10 (44) 0.50 (2.20) 0.32 (1.41) 315 0.80 (3.52) 0.50 (2.20) 200
80 3 200 (880) 160 (704) 16 (70.45) 0.81 (3.57) 0.51 (2.25) 315 1.30 (5.72) 0.80 (3.52) 200 0.6 (2.64) 250
100 4 313 (1378) 250 (1100) 25 (110) 1.30 (5.72) 0.79 (3.48) 315 2.0 (8.81) 1.25 (5.50) 200 1.0 (4.40) 250
125 5 313 (1378) 250 (1100) 25 (110) 1.30 (5.72) 0.79 (3.48) 315 2.0 (8.81) 1.25 (5.50) 200
150 6 788 (3470) 630 (2774) 63 (277) 3.2 (14.09) 2.0 (8.81) 315 5.0 (22.01) 3.2 (14.09) 200 2.52 (11.1) 250
200 8 1250 (5504) 1000 (4403) 100 (440) 5.10 (22.45) 3.2 (14.09) 315 8.0 (35.22) 5.0 (22.01) 200 4.0 (17.61) 250

DS/FER200/FEF200/FEV200–EN Rev. H 7
AquaMaster3
Electromagnetic flowmeter

Specification – FER, FEF and FEV sensors 350 to 600 mm (14 to 24 in.) flanged (FER)
EN1092-1 / ISO 7005 – PN10, PN16
Wetted materials
AS 4087 PN14, PN16, PN21
Screw-end meters AS 2129 Tables C, D
Brass and stainless steel 316L and super-austenitic steel
JIS to B2210 5k and 10k
Flanged meters
25 to 300 mm (1 to 12 in.) flanged (FEF)
Electrodes – stainless steel 316L
EN1092-1 / ISO 7005 – PN10, PN16
Potable water approvals ANSI B16.5 Class 150
WRAS NSF AS / NZS AS 4087, PN16
ACS
Listed Approved 4020
 Pipe conditions
FER   
(DN40 to 600 only) FEF and FEV 5 x pipe dia. 2 x pipe dia.
FEF    
FER 0 x pipe dia. 0 x pipe dia.
FEV    
minimum minimum
Pressure limitations
As flange rating
PN25 Max Process Temp 50 °C (122 °F)
Flow Direction
PN40 Max Process Temp 40 °C (104 °F)
OIML / MID Approved Meters 16 bar (232 psi)
Pressure equipment directive 97/23/EC
This product is applicable in networks for the supply, distribution Pressure loss
and discharge of water and associated equipment and is Flow Rate Pressure Loss in bar (psi)
therefore exempt. Q3 <0.63 (9.1)
FER
Environmental protection Q3 / 2 <0.16 (2.3)
Rating FEV Q3 <0.25 (3.6)
IP68 (NEMA 6P) to 10 m (33 ft.) FEF Q3 Negligible
Buriable (mechanical limitation, sensor only) to 5 m (16 ft.)
OIML R49 approval (FER only)
Temperature limitations Size range and flow specification
Ambient temperature See specification table
 Remote transmitter Accuracy class
– –20 to 70 ° C (–4 to 158 °F) 1 and 2
 Close-coupled or integral transmitter Environmental class
– –20 to 60 ° C (–4 to 140 °F) T50 0.1 °C to 50 °C (32.18 °F to 122 °F)
Process temperature Pressure loss class
 Non-approved < 0.63 bar
– –6 to 70 ° C (21 to 158 °F)
Minimum upstream pipe
 OIML R49 T50 approval 0D
– 0.1 to 50 ° C (32 to 122 °F)
Minimum downstream pipe
Conductivity 0D
>50 µS/cm Orientation
End connections Any
Thread-end connections (FER) MID Approval
15 mm – ISO 228 G 3/4 in. B 3/4 in. NPSM Approved to directive 2004/22/EC
20 mm – ISO 228 G 1 in. B 1 in. NPSM
25 mm – ISO 228 G 11/4 in. B 11/4 in. NPSM
40 to 300 mm (1.5 to 12 in.) flanged (FER)
EN1092-1 / ISO 7005 – PN10, PN16
ANSI B16.5 Class 150
AS 2129 Tables C, D, E and F
AS 4087 PN14, PN16, PN21
JIS to BS2210, 10k

8 DS/FER200/FEF200/FEV200–EN Rev. H
AquaMaster3
Electromagnetic flowmeter

Specification – AquaMaster3 transmitter Pulse and alarm outputs


Three, bidirectional, solid-state switches with common isolation
Mounting
±35 V DC 50mA
Integral with sensor (integral-mount)
Output 1 – forward only or forward plus reverse pulses
or
Output 2 – reverse pulses or direction indicator
Remote up to 200 m (650 ft)
Output 3 – alarm indicates any problem with measurement or
Housing with power
IP68 (NEMA 6P), <2 m (6 ft.)
Pulse output – 50 Hz maximum, 50 % nominal duty cycle
Stainless steel housing in a thermoplastic outer cover with
window, encapsulated with polyurethane-based resin. Communications options
Serial data communications
Electrical connections
Local Port RS232
IP68 plug and socket, mains cable
Note. On battery and renewable energy versions frequent use of
Sensor cable the RS232 or RS485 port considerably reduces battery /
ABB cable supplied as standard standby life.
SWA cable available (via adaptor box) on application RS485 MODBUS
MODBUS RTU slave
Mains supply
85 to 265 V AC @ <3 VA Baud rates:

Connection cable: approx. 3 m (10 ft.) 1200, 2400, 4800, 9600 or 19200

Mains power failure backup time: Standard, approx. 5 days from RS485:
internal super capacitor. Optional, up to 5 years with power
cable option AS and external battery option AD 2-wire + ground signalling
Low power shut-off mode after 10 s of inactivity
Renewable power
Solar or wind Encoder interface / scancoder / scanreader
(non-logging versions only)
Input voltage: 6 to 22 V DC @ <5 W
Function – remote reading of totalizer and serial number
Note. Renewable energy generators do not operate at maximum
 Connections
capacity, for example, low wind speed, coating of the solar
panel, short daylight periods. As a consequence, some – 2-wire for inductive pads
installations require generators with a capacity greater than the (max. cable length 80 m [260 ft])
specified 5 W minimum. – 3-wire for AMR
Max. current: 200 mA
Backup power time up to 3 weeks  Compatible readers
(dependent on operating conditions) – Severn Trent Services Smart reader
External battery pack – ABB or Elster SR100 and SR50
IP68 (NEMA 6P) – Logicon Versaprobe
Manganese alkaline battery life @ 0 to 45 °C (32 to 113 °F): – Itron ERT
Nominal 5 years operation*

Internal battery (integral-mount version only)  Compatible inductive pads


IP68 (NEMA 6P) sensor integral housing – Starpad
Standard lithium thionyl chloride 3.6 V D-cell (x 6)
battery life @ –20 to 60 °C (–4 to 140 °F): *Battery life is shorter with GSM, depending on how frequently it
Nominal 6 years operation* is used and for what period. For example, used once per day for
Suitable batteries, non-solder tag (not supplied): SMS automated reporting of data logged at 15 minute intervals,
 SAFT LS36600 / Tadiran TL-5930 / the life of a battery pack would be typically reduced by 5 %.
Varta ER D / Tekcell SB-D02 Battery life is shorter at extremes of temperature.

Battery changeover backup time


Approximately 2 minutes

DS/FER200/FEF200/FEV200–EN Rev. H 9
AquaMaster3
Electromagnetic flowmeter

Telemetry applications (option) Device languages


English French German
GSM / SMS modem
Mounting: Spanish Italian Dutch
Internal
Pressure system – external transducer (option)
Frequency bands: Pressure range
Quad band: 850 / 900 / 1800 / 1900 MHz 16 bar Abs.
Connection
Functions: Standard quick-fit male probe connector via an adapter cable
SMS auto report of flow and optionally, pressure logger data Operating temperature range
(typically 1 s or 1 min. average) –20 (ambient) to 70 °C (–4 to 158 °F)
SMS report frequency: typically daily Protect the sample and transducer from freezing.
SMS alarm reporting at time of event, for example power loss,
Accuracy (typical)
limited to 1 per day
±0.4 % of range
SMS flowmeter configuration
Thermal error band (typically 100 °C [212 °F])
SMS flowmeter diagnosis ±1.5 % span
SMS total / tariff auto report Cable length
5, 10 or 20 m (16, 33 or 66 ft)
GSM antenna (option)
Quad band operation: Logger details (option)
850 / 900 / 1800 / 1900 MHz
Logger
Mounting: 1 2 3
Integral with transmitter or remote. Forward,
Logger Flow & Flow & Reverse,
Antenna environmental:
Function Pressure Pressure Tariffs & Net
IP66 (NEMA4) waterproof for accidental submersion Flow Totals
Note. The GSM does not operate with integral antenna under No. of Records 8831 11361 732
water. 15 to 65500 s 24 hour
Logging Interval
General advice is to mount the antenna as high as possible, (adjustable) (fixed)
always outside of any metal enclosure and not under the 7 days
surface of the ground. 3 months
Typical Capacity (approx.) 2 years
@15 min
@ 1 min
Temperature ranges

Storage Ambient Software availability

70 °C Software Direct RS232 SMS (Text)


60 °C
(158 °F)
(140 °F) ABB AC800M  
ABB Generic (for example,
 
–10 °C –20 °C
LogMaster)
(14 °F) (–4 °F) Areal (Topkapi)  
MeterVue (I&P AutoChart)  
EcoTech  
Battery capacity and life are shortened when operating outside
the temperature range: HydroComp  

Manganese Alkaline 0 to 45 °C (32 to 113 °F) Mobile phone text  


OSI PI Database or Capula  
Lithium Thionyl Chloride 0 to 60 °C (32 to 140 °F)
QTech  
Response time (programmable) Zeepaard  
Minimum Agua Ambiente Servicios
1 s (mains-powered)  
Integrales SA
15 s (battery-powered + external renewable energy)

10 DS/FER200/FEF200/FEV200–EN Rev. H
AquaMaster3
Electromagnetic flowmeter

Transmitter connections
Transmitter connection overview Input / Output Connections
This section is intended to give an overview of installation of a
flowmeter. For Installation requirements, technical information
and Health and safety precautions – refer to the User Guide
OI/FET200–EN.

A
B F
G
A Pin View
C E
D
WABC 2010
I/O
B
Socket

Remote or close-coupled sensor connections


Connection of the sensor cable B to the transmitter is made
Input / Output connections
via a military-style connector. This can be installed by simply
removing the screwed cap A, and gently pushing the sensor Color
connector B into the socket, rotating it until it engages then Pin Signal Function (Output
tightening the locking ring. Cable)
Not
Input / output connections A
used
Not used Violet

Frequency outputs B DATA ScanReader Data Blue


O/P
C Output Common Yellow
Telemetry, Electronic OV* COM
Counters etc.
COM Reverse Pulses or Direction
Counter / Totalizers D O/P2 Red
12 3 4 56 O/P1
Indicator
Forward flow E O/P3 Alarm Output Brown
12 3 4 5 6 O/P2
and / or Reverse flow Forward Pulses or Forward &
F O/P1 Orange
PLC or Datalogger Reverse Pulses
G 0V Scanreader 0V Screen
Common COM
Input 1 Connector input / output connections
O/P1
Input 2
*Optional link for grounding floating output – see Caution ScanReader interface (option)

Frequency output connections Red


Reading
Pad
Note. Outputs 1 and 2 are not polarity-sensitive. The Black
Part No.
common connection for these outputs is designated ‘COM’. WABC2104 /05, /10, /20, /30/
Cable Colors xx = cable length
Alarm interface Green +V
Red Data
Common COM Black 0V 3-Wire Transponder Connection
Alarm Input O/P 3
ScanReader connections
Alarm output connections

Note. Output 3 is not polarity sensitive. The common


connection for these outputs is designated ‘COM’.

DS/FER200/FEF200/FEV200–EN Rev. H 11
AquaMaster3
Electromagnetic flowmeter

RS232 local computer connection Digital communication

A MODBUS protocol
B F MODBUS is an open standard that is owned and administered
G by an independent group of device manufacturers called the
Modbus Organization (www.modbus.org).
C E
Part No Using the MODBUS protocol, devices from different
D
WEBC2100 manufacturers exchange information on the same
7 Pin MIL
communications bus without the need for special interface
Pin Function equipment. AquaMaster FET2XX-MB follows the specification
A Not used
B RI for Modbus Over Serial Line V1.02, using 2-wire TIA/EIA-485
USB
C CTS (RS485) physical layer.
Connector D RTS
E RXS Please refer to:
F TXS
G 0V  MODBUS Tables Supplement
(COI/FET2XX/MOD/TBL–EN)
RS232 local computer connections  Programming Guide (COI/FET2XX–EN)

Note. Master
 A USB Comms lead driver is required when using 5
Line D R
WEBC2100 – download from Pull
Terminator Pull
www.ftdichip.com/FTDrivers.htm Up
D1
 On battery or renewable energy versions, do not leave an Balanced Pair Line
RS232 connection plugged in or wired with voltages applied
unnecessarily. Such voltages result in far higher power D0
consumption from the battery or backup source, limiting Pull
battery / backup life. Common Down
 The serial port connection shares the same physical port as
the MODBUS connection so (depending on cable design) it R R
D D
may be necessary to disconnect the MODBUS connection
temporarily to enable configuration of AquaMaster3. Slave 1 Slave n Up to 31 slaves
For example, AquaMaster FET2XX–MOD

Typical MODBUS RS485 2-wire network Installation

A
B F
G

C E
Part No
WEBC2101 D
MODBUS

Pin Function
USB A D0
Connector B D1
C Not used
D Not used
E Not used
F Not used
G Not used

Connector B20434 available


for hard-wired installations

MODBUS connection

12 DS/FER200/FEF200/FEV200–EN Rev. H
AquaMaster3
Electromagnetic flowmeter

Cable properties Grounding


The end-to-end length of the trunk cable must be limited. The The flowmeter sensor must be cross-bonded to the upstream
maximum length depends on the Baud rate, the cable (gauge, and downstream pipes. For technical reasons, this potential
capacitance or characteristic impedance), the number of loads should be identical to the potential of the metering fluid. The fluid
on the daisy chain and the network configuration (2-wire or connection is made by installing a minimum of 2 fluid contact
4-wire). rings.
For 9600 Baud rate and AWG26 (or wider) gauge, the maximum
length is 1000 m (3280 ft.). Where 4-wire cabling is used as a
2-wire cabling system the maximum length must be divided by
2. The tap cables must be short, never more than 20 m (65.6
ft.). If a multi-port tap is used with n derivations, each one must
have a maximum length of 40 m (131 ft.) divided by n.
The maximum serial data transmission line length for RS485 Fluid contact rings
systems is 1200 m (3937 ft.). The lengths of cable that can be
used are determined by the cable type, typically:
 Up to 6 m (19.7 ft.) – standard screened or twisted pair
cable.
 Up to 300 m (984 ft.) – twin twisted pair with overall foil
AquaMaster 3

screen and an integral drain wire – for example, Belden


9502 or equivalent.
 Up to 1200 m (3937 ft.) – twin twisted pair with separate
foil screens and integral drain wires – for example, Belden
9729 or equivalent.

Category 5 cables may be used for RS485-MODBUS to a


maximum length of 600 m (1968 ft.). For the balanced pairs
used in an RS485-system, a characteristic impedance with
value higher than 100 is preferred especially for 19200 and
higher Baud rates. Mounting
The installation conditions shown below must be observed to
Installation requirements achieve the best operational results.
This section is intended to give an overview of installation of a The sensor tube must always be completely full.
flowmeter. For Installation requirements, technical information
and Health and Safety precautions refer to User Guide
OI/FER100/FER200-EN.

Unpacking the flowmeter


Care must be taken when lifting the flowmeter to use the lifting
hooks provided or sling under the body of the meter. Never lift
using the terminal connection box of the sensor cable as this will
cause damage and invalidate warranty.
The flow direction must correspond to the identification plate.
The device measures the flowrate in both directions. Forward
Sling Angle <90° flow is the factory setting.
The devices must be installed without mechanical tension
(torsion, bending). If required support the pipeline.

Supports

DS/FER200/FEF200/FEV200–EN Rev. H 13
AquaMaster3
Electromagnetic flowmeter

The flange seals must be made from a compatible material for The cable to the flowmeter should be installed neatly or within a
the fluid and fluid temperatures if required. conduit, both loose or conduit should have a u shape below the
terminal connection box height to allow any water run off to
70 °C avoid any capillary action into the flowmeter sensor.
(158 °F)
Max.

– 20 °C
(– 4 °F)
Min.

Seals must not extend into the flow area since possible
Electrode axis
turbulence could influence the device accuracy.
Electrode axis should be horizontal if at all possible or no more
than 45° from horizontal.

45 ° Max.

Fit Gaskets

Gaskets Same Size as Pipe


Electrode

Axis
The pipeline may not exert any unallowable forces and torques
on the device, such as vibration.

Upstream and downstream pipe sections


The metering principle is independent of the flow profile as long
as swirl does not extend into the metering section, such as may
occur after double elbows, in the event of tangential inflow or
where half-open gate valves are located upstream of the
The flowmeter must not be submitted to any localized heat flowmeter sensor. In such cases, best practice installation
during installation; take care to remember this is a measuring measures should be put in place to normalize the flow profile.
instrument.
 Whereever possible do not install fittings (for example,
manifolds, valves) directly in front of the flowmeter sensor.
 Butterfly valves should be installed so that the valve plate
does not extend into the flowmeter sensor.
 Valves or other turn-off components should be installed in
the Downstream pipe section.
Experience has shown that, in most installations, straight
upstream sections 5 x DN long and straight downstream
sections 2 x DN long are normally sufficient. We would
The flowmeter must not be exposed to direct sunlight or provide recommend conditions of 5 x DN straight upstream and 2 x DN
for appropriate sun protection where necessary. straight downstream where possible.

FER 0 x DN FER 0 x DN

FEV, FEF 5 x DN FEV, FEF 2 x DN

14 DS/FER200/FEF200/FEV200–EN Rev. H
AquaMaster3
Electromagnetic flowmeter

Transmitter dimensions
Remote- and sensor-mounted transmitter Integral transmitter and vandal-resistant housing

Dimensions in mm (in.)
125 (5.0) 50
Ø 6.5 175 (6.9) 244 (9.6)
115 (4.50) (2.0) 220 (8.7)
(0.25)
28 (1.1)
Ø13 AquaMaster 3

214 (8.4)
225 (8.9)
(0.50)

135 (5.3)
160 (6.3)
AquaMaster 3

185

175 (3.9)
136 (7.3)
(5.4)
280 (11.0)
with
connectors

177 (7.0)
Remote-mounted transmitter Integral transmitter dimensions

Dimensions in mm (in.)
Close-coupled
transmitter 105 184 (7.2) 260 (10.2)
(4.1)

225 (8.9)
191 (7.5)
Aquamaster 3 dimensions 182 (7.2)

178 (7.0)
External battery pack

Dimensions in mm (in.)
9 (0.35)
Vandal-resistant housing dimensions

148
(5.83)

150 (5.90) 76 (3.0)

Weight (approx.): 4 kg (8.8 lb)

AquaMaster3 battery pack dimensions

DS/FER200/FEF200/FEV200–EN Rev. H 15
AquaMaster3
Electromagnetic flowmeter

Sensor dimensions
FER – DN15 to 25 (1/2 to 1in. NB) remote sensor

Dimensions in mm (in.)

A
L

DN15 to 25 (1/2 to 1in. NB) (FER) remote sensor

Dimensions in mm (in.) Approx. weight in kg (lb)


(Remote)
DN Process connection type L C G A

DN 15 ¾ in. BSP 64 (2.52) 125 (4.92) 89 (3.50) 2.5 (5.50)


119 (4.69)
(½ in.) ¾ in NPSM

DN 20 1 in. BSP 64 (2.52) 125 (4.92) 89 (3.50)


127 (5.00)
(¾ in.) 1 in. NPSM

DN25 1 1/4 in. BSP 64 (2.52) 125 (4.92) 89 (3.50)


127 (5.00)
(1 in.) 1 1/4 in. NPSM

DN15 to 25 (1/2 to 1in. NB) (FER) remote sensor dimensions / weights

16 DS/FER200/FEF200/FEV200–EN Rev. H
AquaMaster3
Electromagnetic flowmeter

FER – DN40 to 300 (11/2 to 12 in. NB) integral / remote sensor

Dimensions in mm (in.)

224 175
(9.6) (6.9)

AquaMaster 3

89 Ø104
(8.9)
225

(3.5) (4.1)

(3.1)
78
F
E
G

X
L

DN40 to 300 (11/2 to 12 in. NB) (FER) integral / remote sensor

Dimensions in mm (in.) Approx. weight in kg (lb)


DN Process connection type D L F E G X Integral Remote
DN40 EN1092-1 PN10, 16, 25, 40 150 (5.91) 190 (7.48) 260 (10.24) 185 (7.28) 137 (5.39) 23.5 (0.93) 13.4 (29.5) 12.4 (27.3)
1
(1 /2 in.) ASME B16.5 CLASS 150
AS2129 TABLE D, E, F
DN50 EN1092-1 PN10, 16, 25, 40 165 (6.50) 190.5 (7.5) 261 (10.28) 186 (7.32) 138 (5.43) 29 (1.14) 14.75 (32.45) 13.75 (30.25)
(2 in.) ASME B16.5 CLASS 150
DN80 EN1092-1 PN10, 16, 25, 40 200 (7.87) 190.5 (7.5) 280 (11.04) 205.5 (8.09) 157.5 (6.2) 47 (1.85) 21.2 (46.64) 20.2 (44.4)
(3 in.) ASME B16.5 CLASS 150
AS4087 PN16, 21
AS2129 TABLE D, E, F
DN100 EN1092-1 PN10, 16, 25, 40 225 (8.86) 240.5 (9.47) 300.5 (11.83) 225.5 (8.88) 177.5 (6.98) 64 (2.52) 27.3 (60) 26.3 (58)
(4 in.) ASME B16.5 CLASS 150
AS4087 PN16
DN150 EN1092-1 PN10, 16, 25, 40 300 (11.81) 290.5 (11.44) 333.5 (13.13) 258.5 (10.18) 210.5 (8.29) 100.2 (3.94) 27.3 (60) 26.3 (58)
(6 in.) ASME B16.5 CLASS 150
AS4087 PN16
DN200 EN1092-1 PN10, 16 375 (11.76) 340.5 (13.4) 358.7 (14.12) 283.7 (11.17) 235.7 (9.28) 126.7 (5.00) 68 (150) 67 (147.4)
(8 in.) ASME B16.5 CLASS 150
AS2129 TABLE C, D, E, F
AS4087 PN14, 16, 21

AquaMaster3 integral / remote FER – DN40 to 200 (11/2 to 8 in.) cast iron sensor dimensions / weights

DS/FER200/FEF200/FEV200–EN Rev. H 17
AquaMaster3
Electromagnetic flowmeter

Dimensions in mm (in.) Approx. weight in kg (lb)


DN Process connection type D L F C E G X Integral Remote
DN40 EN1092-1 PN10, PN16, PN25, PN40 150 (5.91) 200 (7.87) 285 (11.22) 30.4 (1.20) 215 (8.46) 138 (5.43) 23.5 (0.93) 11 (24) 8 (18)
(1½ in.)
ASME B16.5 CLASS 150 127 (5.00)
JIS 10K 140 (5.51)
AS2129 TABLE C D E 135 (5.31)
AS2129 TABLE F 140 (5.51)
AS4087 PN14 135 (5.31)
DN50 EN1092-1 PN10, 16, 25 & 40 165 (6.50) 200 (7.87) 293 (11.54) 38.3 (1.51) 223 (8.78) 146 (5.75) 29 (1.14) 12 (26) 9 (20)
(2 in.)
ASME B16.5 CLASS 150 152.4 (6.00)
JIS 10K 155 (6.10)
AS2129 TABLE C D E 150 (5.91)
AS2129 TABLE F 165 (6.50)
AS4087 PN14, PN16 150 (5.91)
AS4087 PN21 165 (6.50)

DN65 EN1092-1 PN10, PN16, PN25, PN40 185 (7.28) 200 (7.87) 299 (11.77) 45.2 (1.78) 229 (9.02) 152 (5.98) 37 (1.46) 14 (31) 11 (24)
(2½ in.)
ASME B16.5 CLASS 150 177.8 (7.00)
JIS 10K 175 (6.89)
AS2129 TABLE C D E 165 (6.50)
AS2129 TABLE F 185 (7.28)
AS4087 PN14, PN16 165 (6.50)
AS4087 PN21 185 (7.28)

DN 80 EN1092-1 PN10, PN16, PN25, PN40 200 (7.87) 200 (7.87) 303 (11.93) 51.5 (2.03) 233 (9.17) 156 (6.14) 47 (1.85) 17 (37) 14 (31)
(3 in.)
ASME B16.5 CLASS 150 190.5 (7.50)
JIS 10K 185 (7.28)
AS2129 TABLE C D E 185 (7.28)
AS2129 TABLE F 205 (8.07)
AS4087 PN14, PN16 185 (7.28)
AS4087 PN21 205 (8.07)

DN100 EN1092-1 PN10, PN16 220 (8.66) 250 (9.84) 344 (13.54) 63.75 (2.51) 274 (10.79) 197 (7.76) 64 (2.52) 23 (51) 20 (44)
(4 in.)
EN1092-1 PN25, PN40 235 (9.25)
ASME B16.5 CLASS 150 228.6 (9.00)
JIS 7.5K 238 (9.37)
JIS 10K 210 (8.27)
AS2129 TABLE C D E 215 (8.46)
AS4087 PN14, PN16 215 (8.46)
AS4087 PN21 230 (9.06)

DN125 EN1092-1 PN10, PN16 250 (9.84) 250 (9.84) 344 (13.54) 63.75 (2.51) 274 (10.79) 197 (7.76) 64 (2.52) 26 (57) 23 (51)
(5 in.)
EN1092-1 PN25, PN40 270 (10.63)
ASME B16.5 CLASS 150 254 (10.00)
JIS 10K 250 (9.84)
AS2129 TABLE C D E 255 (10.04)
DN150 EN1092-1 PN10, PN16 285 (11.22) 300 (11.81) 364 (14.33) 84.4 (3.32) 294 (11.57) 217 (8.54) 100.2 (3.94) 36 (79) 33 (72)
(6 in.)
EN1092-1 PN25, PN40 300 (11.81)
ASME B16.5 CLASS 150 279.4 (11.00)
JIS 7.5K 290 (11.42)
JIS 10K 280 (11.02)
AS2129 TABLE C D E 280 (11.02)
AS4087 PN14, PN16 280 (11.02)
AS4087 PN21 305 (12.01)

DN200 EN1092-1 PN10, PN16 340 (13.39) 350 (13.78) 390 (15.35) 109.8 (4.32) 320 (12.60) 243 (9.57) 126.7 (4.99) 51 (112) 48 (106)
(8 in.)
EN1092-1 PN25, PN40 360 (14.17)
ASME B16.5 CLASS 150 345 (13.58)
JIS 7.5K 342 (13.46)
JIS 10K 330 (12.99)
AS2129 TABLE C D E 335 (13.19)
AS4087 PN14, PN16 335 (13.19)
AS4087 PN21 370 (14.57)

DN40 to 300 (11/2 to 12 in. NB) (FER) integral / remote sensor dimensions and weights

18 DS/FER200/FEF200/FEV200–EN Rev. H
AquaMaster3
Electromagnetic flowmeter

Dimensions in mm (in.) Approx. weight in kg (lb)


DN Process connection type D L F C E G X Integral Remote
DN250 EN1092-1 PN10 395 (15.55) 450 (17.72) 415 (16.34) 136.8 (5.39) 345 (13.58) 268 (10.55) 153.5 (6.04) 78 (172) 75 (165)
(10 in.)
EN1092-1 PN16 405 (15.94)
EN1092-1 PN25 425 (16.73)
ASME B16.5 CLASS 150 405 (15.94)
JIS 7.5K 400 (15.75)
JIS 10K 400 (15.75)
AS2129 TABLE C D E 405 (15.94)
AS4087 PN14, PN16 405 (15.94)
AS4087 PN21 430 (16.93)

DN300 EN1092-1 PN10 445 (17.52) 500 (19.69) 441 (17.36) 162.2 (6.39) 371 (14.61) 294 (11.57) 203.5 (8.01) 115 (253) 112 (247)
(12 in.)
EN1092-1 PN16 460 (18.11)
EN1092-1 PN25 485 (19.09)
ASME B16.5 CLASS 150 485 (19.09)
JIS 10K 445 (17.52)
AS2129 TABLE C D E 455 (17.91)
AS4087 PN14, PN16 455 (17.91)
AS4087 PN21 490 (19.29)

DN40 to 300 (11/2 to 12 in. NB) (FER) integral / remote sensor dimensions and weights (Continued)

DS/FER200/FEF200/FEV200–EN Rev. H 19
AquaMaster3
Electromagnetic flowmeter

FER – DN350 to 600 (14 to 24 in. NB) remote sensor

Dimensions in mm (in.)

Ø104
(4.1)
(3.4)
86

G
D

X
A

DN350 to 600 (14 to 24 in. NB) (FER) remote sensor

Dimensions in mm (in.) Approx. weight in kg (lb)

DN Process connection type D L F C E G A X Remote


DN350 (14 in.) EN1092-1 PN10 505 (19.88) 550 (21.65) 472 (18.58) 231 (9.09) 402 (15.83) 325 (12.80) 376 (14.80) 340 (13.39) 100 (220)
EN1092-1 PN16 520 (20.47)
EN1092-1 PN25 555 (21.85)
EN1092-1 PN40 580 (22.83)
JIS 5K 480 (18.90)
JIS 10K 490 (19.29)
AS2129 TABLE C D E 525 (20.67)
AS2129 TABLE F 550 (21.65)
AS4087 PN14, PN16 525 (20.67)
AS4087 PN21 550 (21.65)
DN400 (16 in.) EN1092-1 PN10 565 (22.24) 600 (23.62) 502 (19.76) 257.5 (10.14) 432 (17.01) 355 (13.98) 420 (16.54) 390 (15.35) 115 (253)
EN1092-1 PN16 580 (22.83)
EN1092-1 PN25 620 (24.41)
EN1092-1 PN40 660 (25.98)
JIS 5K 540 (21.26)
JIS 10K 560 (22.05)
AS2129 TABLE C D E 580 (22.83)
AS2129 TABLE F 610 (24.02)
AS4087 PN14, PN16 580 (22.83)
AS4087 PN21 610 (24.02)

DN350 to 600 (14 to 24 in. NB) (FER) remote sensor dimensions / weights

20 DS/FER200/FEF200/FEV200–EN Rev. H
AquaMaster3
Electromagnetic flowmeter

Dimensions in mm (in.) Approx. weight in kg (lb)

DN Process connection type D L F C E G A X Remote


DN450 (18 in.) EN1092-1 PN10 615 (24.21) 700 (27.56) 537 (21.14) 285 (11.22) 467 (18.39) 390 (15.35) 480 (18.90) 440 (17.32) 160 (352)
EN1092-1 PN16 640 (25.20)
EN1092-1 PN25 670 (26.38)
EN1092-1 PN40 685 (26.97)
JIS 5K 605 (23.82)
JIS 10K 620 (24.41)
AS2129 TABLE C D E 640 (25.20)
AS2129 TABLE F 675 (26.57)
AS4087 PN14, PN16 640 (25.20)
AS4087 PN21 675 (26.57)
DN500 (20 in.) EN1092-1 PN10 670 (26.38) 770 (30.31) 557 (21.93) 317.5 (12.50) 487 (19.17) 410 (16.14) 520 (20.47) 490 (19.29) 217 (477)
EN1092-1 PN16 715 (28.15)
EN1092-1 PN25 730 (28.74)
EN1092-1 PN40 755 (29.72)
JIS 5K 655 (25.79)
JIS 10K 675 (26.57)
AS2129 TABLE C D E 705 (27.76)
AS2129 TABLE F 735 (28.94)
AS4087 PN14, PN16 705 (27.76)
AS4087 PN21 735 (28.94)
DN600 (24 in.) EN1092-1 PN10 780 (30.71) 920 (36.22) 602 (23.70) 345 (13.58) 532 (20.94) 455 (17.91) 610 (24.02) 591 (23.27) 315 (693)
EN1092-1 PN16 840 (33.07)
EN1092-1 PN25 845 (33.27)
EN1092-1 PN40 890 (35.04)
JIS 5K 770 (30.31)
JIS 10K 795 (31.30)
AS2129 TABLE C D E 825 (32.48)
AS2129 TABLE F 850 (33.46)
AS4087 PN14, PN16 825 (32.48)
AS4087 PN21 850 (33.46)

DN350 to 600 (14 to 24 in. NB) (FER) remote sensor dimensions / weights (Continued)

DS/FER200/FEF200/FEV200–EN Rev. H 21
AquaMaster3
Electromagnetic flowmeter

FEV – DN40 to 200 (11/2 to 8 in. NB) integral / remote sensor

Dimensions in mm (in.)

224 175
(9.6) (6.9)

AquaMaster 3

89 Ø104
(8.9)
225

(3.5) (4.1)

(3.1)
78
F
E
G

X D

X
L

DN40 to 200 (11/2 to 8 in. NB) (FEV) integral / remote sensor

Dimensions in mm (in.) Approx. weight in kg (lb)


DN Process connection type D L F E G X Integral Remote
DN40 EN1092-1 PN10, 16, 25, 40 150 (5.91) 190 (7.48) 260 (10.24) 185 (7.28) 137 (5.39) 30 (1.18) 12.8 (28.16) 11.8 (25.96)
1
(1 /2 in.) ASME B16.5 CLASS 150
AS2129 TABLE D, E, F
DN50 EN1092-1 PN10, 16, 25, 40 165 (6.50) 190.5 (7.5) 261 (10.28) 186 (7.32) 138 (5.43) 38 (1.5) 13.75 (30.25) 12.75 (28.05)
(2 in.) ASME B16.5 CLASS 150
DN80 EN1092-1 PN10, 16, 25, 40 200 (7.87) 190.5 (7.5) 280 (11.04) 205.5 (8.09) 157.5 (6.2) 61 (2.4) 17.2 (37.84) 16.2 (35.64)
(3 in.) ASME B16.5 CLASS 150
AS4087 PN16, 21
AS2129 TABLE D, E, F
DN100 EN1092-1 PN10, 16, 25, 40 225 (8.86) 240.5 (9.47) 300.5 (11.83) 225.5 (8.88) 177.5 (6.98) 70 (2.76) 19.3 (42.5) 18.3 (40.3)
(4 in.) ASME B16.5 CLASS 150
AS4087 PN16
DN150 EN1092-1 PN10, 16, 25, 40 300 (11.81) 290.5 (11.44) 333.5 (13.13) 258.5 (10.18) 210.5 (8.29) 103 (4.06) 35.1 (77.2) 34.1 (75)
(6 in.) ASME B16.5 CLASS 150
AS4087 PN16
DN200 EN1092-1 PN10, 16 375 (11.76) 340.5 (13.4) 358.7 (14.12) 283.7 (11.17) 235.7 (9.28) 150 (5.91) 67 (147.4) 66 (145.2)
(8 in.) ASME B16.5 CLASS 150
AS2129 TABLE C, D, E, F
AS4087 PN14, 16, 21

WaterMaster integral / remote FEV – DN40 to 200 (11/2 to 8 in.) cast iron sensor dimensions / weights

22 DS/FER200/FEF200/FEV200–EN Rev. H
AquaMaster3
Electromagnetic flowmeter

Dimensions in mm (in.) Approx. weight in kg (lb)


DN Process connection D L F C E G X Integral Remote
type
DN40 EN1092-1 PN10, PN40 150 (5.91) 200 (7.87) 285 (11.22) 30.4 (1.20) 215 (8.46) 138 (5.43) 30 (1.18) 10 (22) 7 (15)
(11/2 in.)
ASME B16.5 CLASS 150 127 (5.00)
JIS 10K 140 (5.51)
AS2129 TABLE F 140 (5.51)
AS2129 TABLE C D E 135 (5.31)
AS4087 PN14 135 (5.31)
DN50 EN1092-1 PN10, PN16 165 (6.50) 200 (7.87) 293 (11.54) 38.3 (1.51) 223 (8.78) 146 (5.75) 38 (1.50) 11 (24) 8 (18)
(2 in.)
ASME B16.5 CLASS 150 152.4 (6.00)
JIS 10K 155 (6.10)
AS4087 PN21 165 (6.50)
AS2129 TABLE F 165 (6.50)
AS2129 TABLE C D E 150 (5.91)
AS4087 PN14, PN16 150 (5.91)
DN65 AS4087 PN14, PN16 165 (6.50) 200 (7.87) 299 (11.77) 45.2 (1.78) 229 (9.02) 152 (5.98) 48 (1.89) 13 (29) 10 (22)
(21/2 in.)
AS2129 TABLE C D E 165 (6.50)
EN1092-1 PN10 185 (7.28)
EN1092-1 PN16 185 (7.28)
DN80 EN1092-1 PN10, PN16 200 (7.87) 200 (7.87) 303 (11.93) 51.5 (2.03) 233 (9.17) 156 (6.14) 61 (2.40) 16 (35) 13 (28)
(3 in.)
ASME B16.5 CLASS 150 190 (7.48)
JIS 7.5K 211 (8.31)
JIS 10K 185 (7.28)
AS2129 TABLE C D E 185 (7.28)
AS4087 PN14, PN16 185 (7.28)
AS2129 TABLE F 205 (8.07)
AS4087 PN21 205 (8.07)
DN100 EN1092-1 PN10, PN16 220 (8.66) 250 (9.84) 344 (13.54) 63.75 (2.51) 274 (10.79) 196.8 (7.75) 70 (2.76) 21 (47) 18 (40)
(4 in.)
ASME B16.5 CLASS 150 228.6 (9.00)
JIS 7.5K 238 (9.37)
JIS 10K 210 (8.27)
AS2129 TABLE C D 215 (8.46)
AS4087 PN14, PN16 215 (8.46)
AS2129 TABLE E 215 (8.46)
AS4087 PN21 230 (9.06)
AS2129 TABLE F 230 (9.06)
DN125 EN1092-1 PN10, PN16 250 (9.84) 250 (9.84) 344 (13.54) 63.75 (2.51) 274 (10.79) 197 (7.76) 70 (2.76) 24 (53) 21 (46)
(5 in.)
ASME B16.5 CLASS 150 254 (10.00)
JIS 10K 250 (9.84)
AS2129 TABLE C D E 255 (10.04)
AS2129 TABLE F 280 (11.02)
DN150 EN1092 PN10, PN16 285 (11.22) 300 (11.81) 364 (14.33) 84.4 (3.32) 294 (11.57) 217 (8.54) 103 (4.06) 34 (75) 31 (68)
(6 in.)
ASME B16.5 CLASS 150 279 (10.98)
JIS 7.5k 290 (11.42)
JIS 10K 280 (11.02)
AS2129 TABLE C D 280 (11.02)
AS4087 PN14, PN16 280 (11.02)
AS2129 TABLE E 280 (11.02)
AS2129 TABLE F 305 (12.01)
AS4087 PN21 305 (12.01)
DN200 EN1092-1 PN10 340 (13.39) 350 (13.78) 390 (15.35) 109.8 (4.32) 320 (12.60) 243 (9.57) 150 (5.91) 53 (116) 50 (110)
(8 in.)
EN1092-1 PN16 340 (13.39)
ASME B16.5 CLASS 150 345 (13.58)
JIS 7.5K 342 (13.46)
JIS 10K 330 (12.99)
AS2129 TABLE C D 335 (13.19)
AS4087 PN14, PN 16 335 (13.19)
AS2129 TABLE E 335 (13.19)
AS2129 TABLE F 370 (14.57)
AS4087 PN21 370 (14.57)

DN40 to 200 (11/2 to 8 in. NB) (FEV) integral / remote sensor dimensions / weights

DS/FER200/FEF200/FEV200–EN Rev. H 23
AquaMaster3
Electromagnetic flowmeter

FEF – DN250 to 600 (10 to 24 in. NB) remote sensor

Dimensions in mm (in.)

Ø104
(4.1)
(3.4)
86

G
D

X
A

DN250 to 600 (10 to 24 in. NB) (FEF) remote sensor

Dimensions in mm (in.) Approx. weight in kg (lb)


DN Process connection type D L C G A

DN250 ASME B16.5 CLASS 150 405 (15.94) 450 (17.72) 215 (8.46) 301 (11.85) 300 (11.81) 88 (194)
(10 in.)
ASME B16.5 CLASS 300 445 (17.52) 490 (19.29)
EN1092 -1 PN10 395 (15.55) 450 (17.72)
EN1092 – 1 PN16 405 (15.94) 450 (17.72)
EN1092 – 1 PN25 425 (16.73) 490 (19.29)
EN1092 – 1 PN40 450 (17.72) 490 (19.29)
JIS 5K 385 (15.16) 450 (17.72)
JIS 10K 400 (15.75) 450 (17.72)
AS4087 PN14, PN16 405 (15.94) 450 (17.72)
AS2129 TABLE C D 450 (17.72)
AS2129 TABLE E 450 (17.72)
AS4087 PN21 430 (16.93) 450 (17.72)
AS2129 TABLE F 450 (17.72)
DN300 ASME B16.5 CLASS 150 485 (19.09) 500 (19.69) 231 (9.09) 317 (12.48) 352 (13.86) 128 (282)
(12 in.)
ASME B16.5 CLASS 300 520 (20.47) 540 (21.26)
EN1092 – 1 PN10 445 (17.52) 500 (19.69)
EN1092 – 1 PN16 460 (18.11) 500 (19.69)
EN1092 – 1 PN25 485 (19.09) 540 (21.26)
EN1092 – 1 PN40 515 (20.28) 540 (21.26)
JIS 5K 430 (16.93) 500 (19.69)
JIS 10K 445 (17.52) 500 (19.69)
AS4087 PN14, PN16 455 (17.91) 500 (19.69)
AS2129 TABLE TABLE C D 455 (17.91) 500 (19.69)
AS2129 TABLE E 455 (17.91) 500 (19.69)
AS4087 PN21 490 (19.29) 500 (19.69)
AS2129 TABLE F 490 (19.29) 500 (19.69)

DN250 to 600 (10 to 24 in. NB) (FEF) remote sensor dimensions / weights

24 DS/FER200/FEF200/FEV200–EN Rev. H
AquaMaster3
Electromagnetic flowmeter

Dimensions in mm (in.) Approx. weight in kg (lb)


DN Process connection type D L C G A

DN350 ASME B16.5 CLASS 150 535 (21.06) 550 (21.65) 257.5 (10.14) 346 (13.62) 376 (14.80) 100 (220)
(14 in.)
ASME B16.5 CLASS 300 585 (23.03) 570 (22.44)
EN1092 – 1 PN10 505 (19.88) 550 (21.65)
EN1092 – 1 PN16 520 (20.47) 550 (21.65)
EN1092 – 1 PN25 555 (21.85) 570 (22.44)
EN1092 – 1 PN40 580 (22.83) 570 (22.44)
JIS 5K 480 (18.90) 550 (21.65)
JIS 7.5K 530 (20.87) 550 (21.65)
JIS 10K 490 (19.29) 550 (21.65)
AS4087 PN14, PN16 525 (20.67) 550 (21.65)
AS2129 TABLE C D E 525 (20.67) 550 (21.65)
AS4087 PN21 550 (21.65) 550 (21.65)
AS2129 TABLE F 550 (21.65) 550 (21.65)
AS4087 PN35 550 (21.65) 570 (22.44)
AS2129 TABLE H 550 (21.65) 570 (22.44)
DN375 AS4087 PN14, PN16 550 (21.65) 550 (21.65) 257.5 (10.14) 346 (13.62) 376 (14.80) 115 (253)
(15 in.)
AS2129 TABLE C 550 (21.65) 550 (21.65)
AS4087 PN35 580 (22.83) 570 (22.44)
DN400 ASME B16.5 CLASS 150 600 (23.62) 600 (23.62) 285 (11.22) 371 (14.61) 420 (16.54) 115 (253)
(16 in.)
ASME B16.5 CLASS 300 650 (25.59) 620 (24.41)
EN1092 – 1 PN10 565 (22.24) 600 (23.62)
EN1092 – 1 PN16 580 (22.83) 600 (23.62)
EN1092 – 1 PN25 620 (24.41) 620 (24.41)
EN1092 – 1 PN40 660 (25.98) 620 (24.41)
JIS 5K 540 (21.26) 600 (23.62)
JIS 7.5K 582 (22.91) 600 (23.62)
JIS 10K 560 (22.05) 600 (23.62)
AS4087 PN14, PN16 580 (22.83) 600 (23.62)
AS2129 TABLE C D E 580 (22.83) 600 (23.62)
AS4087 PN21 610 (24.02) 600 (23.62)
AS2129 TABLE F 610 (24.02) 600 (23.62)
AS4087 PN35 610 (24.02) 620 (24.41)
AS2129 TABLE H 610 (24.02) 620 (24.41)
DN450 ASME B16.5 CLASS 150 635 (25.00) 700 (27.56) 317.5 (12.50) 402 (15.83) 480 (18.90) 160 (352)
(18 in.)
ASME B16.5 CLASS 300 710 (27.95)
EN1092 – 1 PN10 615 (24.21)
EN1092 – 1 PN16 640 (25.20)
EN1092 – 1 PN25 670 (26.38)
EN1092 – 1 PN40 685 (26.97)
JIS 5K 605 (23.82)
JIS 7.5K 652 (25.67)
JIS 10K 620 (24.41)
AS4087 PN14, PN16 640 (25.20)
AS2129 TABLE C D 640 (25.20)
AS2129 TABLE E 640 (25.20)
AS4087 PN21 675 (26.57)
AS2129 TABLE F 675 (26.57)
AS4087 PN35 675 (26.57)
AS2129 TABLE H 675 (26.57)

DN250 to 600 (10 to 24 in. NB) (FEF) remote sensor dimensions / weights (Continued)

DS/FER200/FEF200/FEV200–EN Rev. H 25
AquaMaster3
Electromagnetic flowmeter

Dimensions in mm (in.) Approx. weight in kg (lb)


DN Process connection type D L C G A

DN500 ASME B16.5 CLASS 150 700 (27.56) 770 (30.31) 345 (13.58) 429 (16.89) 520 (20.47) 217 (455)
(20 in.)
ASME B16.5 CLASS 300 775 (30.51)
EN1092 – 1 PN10 670 (26.38)
EN1092 – 1 PN16 715 (28.15)
EN1092 – 1 PN25 730 (28.74)
EN1092 – 1 PN40 755 (29.72)
JIS 5K 655 (25.79)
JIS 7.5K 706 (27.80)
JIS 10K 675 (26.57)
AS4087 PN 14, PN16 705 (27.76)
AS2129 TABLE C D E 705 (27.76)
AS4087 PN21 735 (28.94)
AS2129 TABLE F 735 (28.94)
AS4087 PN35 735 (28.94)
AS2129 TABLE H 735 (28.94)
DN600 ASME B16.5 CLASS 150 815 (32.09) 920 (36.22) 387.5 (15.25) 472 (18.58) 610 (24.02) 315 (693)
(24 in.)
ASME B16.5 CLASS 300 915 (36.02)
EN1092 – 1 PN10 780 (30.71)
EN1092 – 1 PN16 840 (33.07)
EN1092 – 1 PN25 845 (33.27)
EN1092 – 1 PN40 890 (35.04)
JIS 5K 770 (30.31)
JIS 7.5K 810 (31.89)
JIS 10K 795 (31.30)
AS4087 PN14, PN16 825 (32.48)
AS2129 TABLE C D 825 (32.48)
AS2129 TABLE E 825 (32.48)
AS4087 PN21 850 (33.46)
AS2129 TABLE F 850 (33.46)
AS4087 PN35 850 (33.46)
AS2129 TABLE H 850 (33.46)

DN250 to 600 (10 to 24 in. NB) (FEF) remote sensor dimensions / weights (Continued)

26 DS/FER200/FEF200/FEV200–EN Rev. H
AquaMaster3
Electromagnetic flowmeter

Ordering information
AquaMaster FER reduced-bore sensor flowmeter series
Product coding field number 1,2,3,4,5,6 7,8,9 10 11 12 13 14,15 16 17 18 19 20 21 22 23 24 25 26 27 Options
AquaMaster system. Reduced-bore sensor with integral mounted

Add as required – see next page


FER211
transmitter (DN40 to 300 only)
AquaMaster system. Reduced-bore sensor with remote mounted
FER221
transmitter
AquaMaster system. Reduced-bore sensor with close coupled
FER251
transmitter
XXX X X X X XX X X X X X X X X X X X X
AquaMaster reduced-bore sensor only, close coupled, without
FER271
transmitter
AquaMaster reduced-bore sensor only, remote mount, without
FER281
transmitter
AquaMaster reduced-bore sensor only, integral mount, without
FER291
transmitter (DN40 to 300 only)
Bore diameter
DN 15 (1/2 in.) 015
DN 20 (3/4 in.) 020
DN 25 (1 in.) 025
DN 40 (11/2 in.) 040
DN 50 (2 in.) 050
DN 65 (21/2 in.) 065
DN 80 (3 in.) 080
DN 100 (4 in.) 100
DN 125 (5 in.) 125
DN 150 (6 in.) 150
DN 200 (8 in.) 200
DN 250 (10 in.) 250
DN 300 (12 in.) 300
DN 350 (14 in.) 350
DN 375 (15 in.) 375
DN 400 (16 in.) 400
DN 450 (18 in.) 450
DN 500 (20 in.) 500
DN 600 (24 in.) 600
Liner material

Elastomer – DN40 to 600 (11/2 to 24 in.) K


PPS – DN15 to 25 (1/2 to 1 in.) R
Electrode design
Standard 1
Measuring electrodes material
Stainless steel 316 S
Super Austenitic steel (1.4529) – DN40 to 600 (11/2 to 24 in.) U
Grounding accessories
2 x stainless steel potential equalizing rings 4
Process connection type (refer to pages 16 to 21)

Flanges ANSI / ASME B16.5 / 16.47 series B Class 150 (DN40 / 50 / 80 / 100 / 150 to 300) A1
Flanges AWWA C207 Class E (DN40 / 50 / 80) C3
Flanges JIS 10K (DN40 / 50 / 80 / 100 / 150 to 300) J1
Flanges JIS 5K (DN100 to 300) J2
Flanges AS 4087 PN 21 (DN50 / 80 / 100 / 150 to 600) E0
Flanges AS 4087 PN 16 (DN50 / 80 / 100 / 150 to 350 / 450 to 600) E1
Flanges AS 4087 PN 14 (DN40 to 300) E2
Flanges AS 2129 Table F (DN40 / 50 / 80 / 100 / 150 to 600) E3
Flanges AS 2129 Table E (DN40 / 50 / 80) E4
Flanges AS 2129 Table D (DN40 / 50 / 80 / 100 / 150 to 300) E5
Flanges AS2129 Table C (DN40 to 300) E6
ISO 7005 PN 10 EN 1092-1 (DN40 to 600) S1
ISO 7005 PN 16 EN 1092-1 (DN40 to 600) S2
ISO 7005 PN 40 EN 1092-1 (DN40) S4
Male thread acc. ISO 228 / DIN 2999 (conical) (DN15 to 25) M1
Male thread acc. NPSM (conical) (DN15 to 25) M2
Process connection material
Brass – DN15 to 25 (1/2 to 1 in.) A
Carbon steel – DN40 to 600 (11/2 to 24 in.) B
Usage certifications
Standard 1
Calibration type
Standard Class 2 factory calibration A
Standard Class 1 factory calibration B
Enhanced Class 2 factory calibration P
Enhanced Class 1 factory calibration N
Installation temperature range / ambient temperature range
Standard design –20 to 60 °C (–4 to 140 °F) 1

Name plate
Adhesive label A
Continued on next page …

DS/FER200/FEF200/FEV200–EN Rev. H 27
AquaMaster3
Electromagnetic flowmeter

AquaMaster FER reduced-bore sensor flowmeter series (Continued)


Product coding field number 1,2,3,4,5,6 7,8,9 10 11 12 13 14,15 16 17 18 19 20 21 22 23 24 25 26 27 Options
Signal cable length and type
Without signal cable 0
5 m (16.4 ft) 1
10 m (32.8 ft) 2
20 m (65.6 ft) 3
30 m (98.4 ft) 4
50 m (164.0 ft) 5
80 m (262.5 ft) 6
Others 9
Explosion protection certification
Without A
Protection class transmitter / protection class sensor
IP68 (NEMA 6P) / IP68 (NEMA 6P) – cable not fitted and not potted* 5
IP68 (NEMA 6P) / IP68 (NEMA 6P) – cable fitted and potted 6
Cable conduits
MIL style G
Power supply
Battery powered – battery not fitted 5
AC + internal back-up 7
External renewable energy 8
Input and output signal type
MODBUS M
Mobile communication H
ScanReader S
Without (Note. Pulse outputs and RS232 are always present) Y
Configuration type / diagnostics type
Parameters set to factory defaults 1
Options – add to order code

Transmitter related Sensor related

Accessories Other usage certifications


Configuration lead RS232 AC MID, DN40 to 300 (11/2 to 12 in.), N/P calibration only CM1
Standard battery pack AD OIML R049, DN40 to 300 (11/2 to 12 in.), N/P calibration only CM2
AC + external battery back-up connector (power supply option 7 only) AS
Modbus cable RS485 AT
Anti-vandal cover (integral only) – future option AV

Mobile communication Verification type


Without G0 Without fingerprint V0
Integral (850 / 900 / 1800 / 1900 MHz) G3 With CalMaster fingerprint V2
Remote 1 m (850 / 900 / 1800 / 1900 MHz) G6
Remote 5 m (850 / 900 / 1800 / 1900 MHz) G7
Remote 10 m (850 / 900 / 1800 / 1900 MHz) G8
Potable water and Food & Beverage approvals
Logger and protocol
ABB Logger – Capula / BVS LP2 WRAS CWA
ABB Logger – Hydreka LP5 AS4020 CWE
ABB Logger – QTech LP6 ACS CWF
ABB Logger – Areal Topkai LP7
ABB Logger – EcoTech LP8
ABB Logger – Autochart I+P LP9
ABB Logger – HydroComp LPA
ABB Logger – ABB Generic (e.g. LogMaster) LPB
ABB Logger – ABB AC800M System LPC
ABB Logger – Zeepaard LPE
ABB Logger – Agua Ambiente Servicios Integrales SA LPF
Not Required / No Logger LP0
Others LPZ
Documentation language Pressure transducer
German (pending) M1 Remote, no transducer PT2
Italian (pending) M2 Remote, cable length 5 m (15 ft) PT4
Spanish (pending) M3 Remote, cable length 10 m (33 ft) PT5
French (pending) M4 Remote, cable length 20 m (65 ft) PT6
English M5 Without PT0
Others PTZ

Pressure span
1000 kPa / 10 bar / 145 psi PS1
1600 kPa / 16 bar / 232 psi PS2
2000 kPa / 20 bar / 300 psi PS3
Without PS0
Others PSZ
* Only IP68 after potting by others

28 DS/FER200/FEF200/FEV200–EN Rev. H
AquaMaster3
Electromagnetic flowmeter

AquaMaster FEF full-bore sensor flowmeter series


Product coding field number 1,2,3,4,5,6 7,8,9 10 11 12 13 14,15 16 17 18 19 20 21 22 23 24 25 26 27 Options

Add as required – see next page


AquaMaster system. Full-bore sensor with remote mounted
FEF221
transmitter
AquaMaster system. Full-bore sensor with close coupled transmitter FEF251 XXX X X X X XX X X X X X X X X X X X X
AquaMaster full-bore sensor only, close coupled, without transmitter FEF271
AquaMaster full-bore sensor only, remote mount, without transmitter FEF281
Bore diameter
DN 250 (10 in.) 250
DN 300 (12 in.) 300
DN 350 (14 in.) 350
DN 375 (15 in.) 375
DN 400 (16 in.) 400
DN 450 (18 in.) 450
DN 500 (20 in.) 500
DN 600 (24 in.) 600
Liner material

Elastomer – DN250 to 600 (10 to 24 in.) K

Electrode design
Standard 1
Measuring electrodes material
Stainless steel 316 S
Super Austenitic steel (1.4529) – DN250 to 600 (10 to 24 in.) U
Grounding accessories
2 x stainless steel potential equalizing rings 4
Process connection type (refer to pages 24 to 26)

Flanges ANSI / ASME B16.5 / 16.47 series B Class 150 (DN250 to 350 / 400 to 600) A1
Flanges ANSI / ASME B16.5 / 16.47 series B Class 300 (DN250 to 350 / 400 to 600) A3
Flanges JIS 7.5K (DN250 to 350 / 400 to 600) J0
Flanges JIS 10K (DN250 to 350 / 400 to 600) J1
Flanges JIS 5K (DN250 to 350 / 400 to 600) J2
Flanges AS 4087 PN 21 (DN250 to 350 / 400 to 600) E0
Flanges AS 4087 PN 16 (DN250 to 600) E1
Flanges AS 4087 PN 14 (DN250 to 600) E2
Flanges AS 2129 Table F (DN250 to 350 / 400 to 600) E3
Flanges AS 2129 Table E (DN250 to 350 / 400 to 600) E4
Flanges AS 2129 Table D (DN250 to 350 / 400 to 600) E5
ISO 7005 PN 10 EN 1092-1 (DN250 to 350 / 400 to 600) S1
ISO 7005 PN 16 EN 1092-1 (DN250 to 350 / 400 to 600) S2
ISO 7005 PN 25 EN 1092-1 (DN250 to 350 / 400 to 600) S3
ISO 7005 PN 40 EN 1092-1 (DN250 to 350 / 400 to 600) S4
Process connection material
Carbon steel B
Usage certifications
Standard 1
Calibration type
Standard Class 2 factory calibration A
Standard Class 1 factory calibration B
Enhanced Class 2 factory calibration P
Enhanced Class 1 factory calibration N
Installation temperature range / ambient temperature range
Standard design –20 to 60 °C (–4 to 140 °F) 1

Name plate
Adhesive label A
Signal cable length and type
Without signal cable 0
5 m (16.4 ft) 1
10 m (32.8 ft) 2
20 m (65.6 ft) 3
30 m (98.4 ft) 4
50 m (164.0 ft) 5
80 m (262.5 ft) 6
Others 9
Explosion protection certification
Without A
Protection class transmitter / protection class sensor
IP68 (NEMA 6P) / IP68 (NEMA 6P) – cable not fitted and not potted* 5
IP68 (NEMA 6P) / IP68 (NEMA 6P) – cable fitted and potted 6
Cable conduits
MIL style G
Continued on next page…

DS/FER200/FEF200/FEV200–EN Rev. H 29
AquaMaster3
Electromagnetic flowmeter

AquaMaster FEF full-bore sensor flowmeter series (Continued)


Product coding field number 1,2,3,4,5,6 7,8,9 10 11 12 13 14,15 16 17 18 19 20 21 22 23 24 25 26 27 Options
Power supply
Battery powered – battery not fitted 5
AC + internal back-up 7
External renewable energy 8
Input and output signal type
MODBUS with RS485 M
Mobile communication H
ScanReader S
Without (Note. Pulse outputs and RS232 are always present) Y
Configuration type / diagnostics type
Parameters set to factory defaults 1
Options – add to order code

Transmitter related Sensor related

Accessories Verification type


Configuration lead RS232 AC Without fingerprint V0
Standard battery pack AD With CalMaster fingerprint V2
AC + external battery back-up connector (power supply option 7 only) AS
Modbus cable RS485 AT

Mobile communication Potable water and Food & Beverage approvals


Without G0 WRAS CWA
Integral (850 / 900 / 1800 / 1900 MHz) G3 NSF61 CWC
Remote 1 m (850 / 900 / 1800 / 1900 MHz) G6 AS4020 CWE
Remote 5 m (850 / 900 / 1800 / 1900 MHz) G7 ACS CWF
Remote 10 m (850 / 900 / 1800 / 1900 MHz) G8

Logger and protocol Pressure transducer


ABB Logger – Capula / BVS LP2 Remote, no transducer PT2
ABB Logger – Hydreka LP5 Remote, cable length 5 m (15 ft) PT4
ABB Logger – QTech LP6 Remote, cable length 10 m (33 ft) PT5
ABB Logger – Areal Topkai LP7 Remote, cable length 20 m (65 ft) PT6
ABB Logger – EcoTech LP8 Without PT0
ABB Logger – Autochart I+P LP9 Others PTZ
ABB Logger – HydroComp LPA
ABB Logger – ABB Generic (e.g. LogMaster) LPB
ABB Logger – ABB AC800M System LPC
ABB Logger – Zeepaard LPE
ABB Logger – Agua Ambiente Servicios Integrales SA LPF
Not Required / No Logger LP0
Others LPZ

Documentation language
German (pending) M1
Italian (pending) M2
Spanish (pending) M3
French (pending) M4
English M5

Pressure span
1000 kPa / 10 bar / 145 psi PS1
1600 kPa / 16 bar / 232 psi PS2
2000 kPa / 20 bar / 300 psi PS3
Without PS0
Others PSZ
* Only IP68 after potting by others

30 DS/FER200/FEF200/FEV200–EN Rev. H
AquaMaster3
Electromagnetic flowmeter

AquaMaster FEV optimized full-bore sensor flowmeter series


Product coding field number 1,2,3,4,5,6 7,8,9 10 11 12 13 14,15 16 17 18 19 20 21 22 23 24 25 26 27 Options
AquaMaster system. optimized full-bore sensor with

Add as required – see next page


FEV211
integral-mounted transmitter
AquaMaster system. optimized full-bore sensor with
FEV221
remote-mounted transmitter
AquaMaster system. optimized full-bore sensor with
FEV251
close-coupled transmitter
XXX X X X X XX X X X X X X X X X X X X
AquaMaster optimized full-bore sensor only,
FEV271
close-coupled, without transmitter
AquaMaster optimized full-bore sensor only,
FEV281
remote-mount, without transmitter
AquaMaster optimized full-bore sensor only,
FEV291
integral-mount, without transmitter
Bore diameter
DN 40 (11/2 in.) 040
DN 50 (2 in.) 050
DN 65 (21/2 in.) 065
DN 80 (3 in.) 080
DN 100 (4 in.) 100
DN 125 (5 in.) 125
DN 150 (6 in.) 150
DN 200 (8 in.) 200
Liner material

Polypropylene – DN40 to 200 (11/2 to 8 in.) V

Electrode design
Standard 1
Measuring electrodes material
Stainless steel 316 S
Super Austenitic steel (1.4529) – DN40 to 200 (11/2 to 8 in.) U
Grounding accessories
2 x stainless steel potential equalizing rings 4
Process connection type (refer to pages 22 and 23)

Flanges ANSI / ASME B16.5 / 16.47 series B Class 150 A1


Flanges JIS 7.5K (DN80 / 100 / 150 / 200) J0
Flanges JIS 10K (DN40 / 50 / 80 / 100 / 150 / 200) J1
Flanges AS 4087 PN 21 (DN50 / 80 / 100 / 150 / 200) E0
Flanges AS 4087 PN 16 (DN50 / 80 / 100 / 150 / 200) E1
Flanges AS 2129 Table F (DN40 / 50 / 80 / 100 / 150 / 200) E3
Flanges AS 2129 Table E (DN40 / 50 / 80 / 100 / 125 / 150 / 200) E4
Flanges AS 2129 Table D (DN40 / 50 / 80 / 100 / 150 / 200) E5
ISO 7005 PN 10 EN 1092-1 S1
ISO 7005 PN 16 EN 1092-1 S2
ISO 7005 PN 40 EN 1092-1 S4
Process connection material
Carbon steel – DN40 to 200 (11/2 to 8 in.) B
Usage certifications
Standard 1
Calibration type
Standard Class 2 factory calibration A
Standard Class 1 factory calibration B
Enhanced Class 2 factory calibration P
Enhanced Class 1 factory calibration N
Class 2.5 J
Installation temperature range / ambient temperature range
Standard design –20 to 60 °C (–4 to 140 °F) 1

Name plate
Adhesive label A
Signal cable length and type
Without signal cable 0
5 m (16.4 ft) 1
10 m (32.8 ft) 2
20 m (65.6 ft) 3
30 m (98.4 ft) 4
50 m (164.0 ft) 5
80 m (262.5 ft) 6
Others 9
Explosion protection certification
Without A
Protection class transmitter / protection class sensor
IP68 (NEMA 6P) / IP68 (NEMA 6P) – cable not fitted and not potted* 5
IP68 (NEMA 6P) / IP68 (NEMA 6P) – cable fitted and potted 6
Cable conduits
MIL style G
Continued on next page…

DS/FER200/FEF200/FEV200–EN Rev. H 31
AquaMaster3
Electromagnetic flowmeter

AquaMaster FEV optimized full-bore sensor flowmeter series (Continued)


Product coding field number 1,2,3,4,5,6 7,8,9 10 11 12 13 14,15 16 17 18 19 20 21 22 23 24 25 26 27 Options
Power supply
Battery powered – battery not fitted 5
AC + internal back-up 7
External renewable energy 8
Input and output signal type
MODBUS with RS485 M
Mobile communication H
ScanReader S
Without (Note. Pulse outputs and RS232 are always present) Y
Configuration type / diagnostics type
Parameters set to factory defaults 1
Options – add to order code

Transmitter related Sensor related

Accessories Other usage certifications


Configuration lead RS232 AC NMI (pending) * CM3
Standard battery pack AD
AC + external battery back-up connector (power supply option 7 only) AS * not applicable to DN65 or 125 (21/2 or 5 in.) sensors
Modbus cable RS485 AT
Anti-vandal cover (integral only) – future option AV

Mobile communication Verification type


Without G0 Without fingerprint V0
Integral (850 / 900 / 1800 / 1900 MHz) G3 With CalMaster fingerprint V2
Remote 1 m (850 / 900 / 1800 / 1900 MHz) G6
Remote 5 m (850 / 900 / 1800 / 1900 MHz) G7
Remote 10 m (850 / 900 / 1800 / 1900 MHz) G8

Logger and protocol Potable water and Food & Beverage approvals
ABB Logger – Capula / BVS LP2 WRAS CWA
ABB Logger – Hydreka LP5 NSF61 CWC
ABB Logger – QTech LP6 AS4020 CWE
ABB Logger – Areal Topkai LP7
ABB Logger – EcoTech LP8
ABB Logger – Autochart I+P LP9
ABB Logger – HydroComp LPA
ABB Logger – ABB Generic (e.g. LogMaster) LPB
ABB Logger – ABB AC800M System LPC
ABB Logger – Zeepaard LPE
ABB Logger – Agua Ambiente Servicios Integrales SA LPF
Not Required / No Logger LP0
Others LPZ
Documentation language Pressure transducer
German (pending) M1 Remote, no transducer PT2
Italian (pending) M2 Remote, cable length 5 m (15 ft) PT4
Spanish (pending) M3 Remote, cable length 10 m (33 ft) PT5
French (pending) M4 Remote, cable length 20 m (65 ft) PT6
English M5 Without PT0
Others PTZ

Pressure span
1000 kPa / 10 bar / 145 psi PS1
1600 kPa / 16 bar / 232 psi PS2
2000 kPa / 20 bar / 300 psi PS3
Without PS0
Others PSZ

*Only IP68 after potting by others

32 DS/FER200/FEF200/FEV200–EN Rev. H
AquaMaster3
Electromagnetic flowmeter

AquaMaster3 transmitter
AquaMaster3 transmitter only, remote- or close-coupled mount FET2211A0Y5G Options
X X X
AquaMaster3 transmitter only, integral mount FET2111A0Y5G
Power supply

Battery 5
AC + backup 7
External renewable energy 8
Input and output signal type
Mobile radio communication H
MODBUS with RS485 M
ScanReader S
Without Y
Note. Pulse outputs and RS232 are always present
Configuration
Standard 1

Options – add to order code

Transmitter related Sensor related

Accessories Other usage certifications


Configuration lead RS232 AC MID (Measurement Instrument Directive) – CM2
Standard battery pack (remote only) AD FER2, DN40 to 300 (11/2 to 12 in.) sensors only
AC + external battery back-up connector (power supply option 7 only) AS
Modbus cable RS485 AT NMI – FEV sensor only (pending) * CM3
Anti-vandal cover (integral only) – future option AV * not applicable to DN65 or 125 (21/2 or 5 in.) sensors

Mobile communication Pressure transducer


Without G0 Remote, no transducer PT2
Integral (850 / 900 / 1800 / 1900 MHz) G3 Remote, cable length 5 m (15 ft) PT4
Remote 1 m (850 / 900 / 1800 / 1900 MHz) G6 Remote, cable length 10 m (33 ft) PT5
Remote 5 m (850 / 900 / 1800 / 1900 MHz) G7 Remote, cable length 20 m (65 ft) PT6
Remote 10 m (850 / 900 / 1800 / 1900 MHz) G8 Without PT0
Others PTZ

Logger and protocol


ABB Logger – Capula / BVS LP2
ABB Logger – Hydreka LP5
ABB Logger – QTech LP6
ABB Logger – Areal Topkai LP7
ABB Logger – EcoTech LP8
ABB Logger – Autochart I+P LP9
ABB Logger – HydroComp LPA
ABB Logger – ABB Generic (e.g. LogMaster) LPB
ABB Logger – ABB AC800M System LPC
ABB Logger – Zeepaard LPE
ABB Logger – Agua Ambiente Servicios Integrales SA LPF
Not Required / No Logger LP0
Others LPZ

Documentation language
German (pending) M1
Italian (pending) M2
Spanish (pending) M3
French (pending) M4
English M5

Pressure span
1000 kPa / 10 bar / 145 psi PS1
1600 kPa / 16 bar / 232 psi PS2
2000 kPa / 20 bar / 300 psi PS3
Without PS0
Others PSZ

DS/FER200/FEF200/FEV200–EN Rev. H 33
AquaMaster3
Electromagnetic flowmeter

Common accessories
MRBX9969 Close-coupled mounting kit
Remote GSM aerial kit:
WEBC2003/01 1 m (3.3 ft.)
WEBC2003/05 5 m (16.4 ft.)
WEBC2003/10 10 m (32 ft.)
MIL connector:
B20433 4-pin MIL – renewable power connector
B20434 7-pin MIL – RS485 MODBUS and RS232 connector
Batteries / spares
WABC2100 Remote battery pack (MnO2)
MEBX2110 Integral battery carrier assembly (replacement spare)
Integral battery type 3.6 V Lithium Thionyl Chloride, size D
Recommended manufacturer part numbers:
SAFT LS 33600 / Tadiran TL-5930 / Varta ER D / Tekcell SB-D02
Sensor cable assembly:
WABC2010 0.5 m (1.6 ft.), for integral / close-coupled
WABC2010/01 1 m (3.3 ft.), for remote
WABC2010/05 5 m (16.4 ft.), for remote
WABC2010/10 10 m (32.8 ft.), for remote
WABC2010/20 20 m (65.6 ft.), for remote
WABC2010/30 30 m (98.4 ft.), for remote
WABC2010/40 40 m (131.2 ft.), for remote
WABC2010/50 50 m (164.0 ft.), for remote
WABC2010/60 60 m (196.8 ft.), for remote
WABC2010/70 70 m (229.6 ft.), for remote
WABC2010/80 80 m (262.4 ft.), for remote
Output cable:
WABC2010/01 1 m (3.3 ft.) wire-ended
WEBC2011/M for Technolog Cello (MIL)
WEBC2012/M for Technolog Cello (Brad Harrsion)
WEBC2013/M for RADCOM Multilog
WEBC2014/M for Primayer Xilog
WEBC2006/M 2x19-way MIL
WEBC2024 Connector security plug – pack of 5
Communication cable:
WEBC2100 RS232 to USB
WEBC2101 RS485 to USB
Pressure cable assembly:
WABX2000/05 16 bar (232 psi), 5 m (16.4 ft.)
WABX2000/10 16 bar (232 psi), 10 m (32.8 ft.)

34 DS/FER200/FEF200/FEV200–EN Rev. H
AquaMaster3
Electromagnetic flowmeter

Adapter cable / upgrade kits


Pressure adapter kit:
WABC2036 M16 Plastic to MIL
Sensor upgrade kit:
WABC2022/M M20 Plastic to MIL
WABC2023/M M20 Armored to MIL
Sensor adaptor kit:
WABC2035 M16 Plastic to MIL
WABC2024/M M20 Plastic to MIL
WABC2025/M M20 Armored to MIL
WABC2026/M ½ in. NPT blanked to MIL
Scanreader cable assembly:
WABC2104/05 5 m (16.4 ft.)
WABC2104/10 10 m (32.8 ft.)
WABC2104/20 20 m (65.6 ft.)
WABC2104/30 30 m (98.4 ft.)

Acknowledgements & Copyrights


Capula© is a copyright of Capula Limited 2010.
EcoTech™ is a registered trademark of
EcoTech Pty Ltd.
HydroComp is a copyright of HydroComp Inc 2010.
Microsoft Excel™ and Windows™ are registered trademarks of the Microsoft Corp.
MODBUS™ is a registered trademark of MODBUS corporation.
OSI™ is a registered trademarks of WADIS.
PMAC™ is a registered trademark of Technolog.
Primeware™ is a registered trademark of Primayer.
QTech™ is a registered trademark of QTech Data Systems Limited.
MeterVue© is a copyright of Information and Performance Services (I&P).
Topkapi™ is a registered trademark of AREAL.
Vodafone PAKNET™ and Vodafone Radiopad™ are registered trademarks of Vodafone.
Zeepaard is a copyright of Zeepaard Engineering Sdn.Bhd.

DS/FER200/FEF200/FEV200–EN Rev. H 35
Contact us

ABB Limited Note

DS/FER200/FEF200/FEV200–EN Rev. H 01.2013


Process Automation We reserve the right to make technical changes or
modify the contents of this document without prior
Oldends Lane
notice. With regard to purchase orders, the agreed
Stonehouse particulars shall prevail. ABB does not accept any
Gloucestershire GL10 3TA responsibility whatsoever for potential errors or
UK possible lack of information in this document.

Tel: +44 1453 826 661


We reserve all rights in this document and in the
Fax: +44 1453 829 671 subject matter and illustrations contained therein.
Any reproduction, disclosure to third parties or
utilization of its contents in whole or in parts – is
forbidden without prior written consent of ABB.
ABB Inc.
Process Automation Copyright© 2013 ABB
125 E. County Line Road All rights reserved
Warminster
PA 18974 3KXF223204R1001

USA
Tel: +1 215 674 6000
Fax: +1 215 674 7183

ABB Engineering (Shanghai) Ltd.


Process Automation
No.5, Lane 369, Chuangye Road Sales
201319, Shanghai, P.R. China
Tel: +86 (0) 21 61056666
Fax: +86 (0) 21 61056992
Mail: [email protected]
Service
www.abb.com

Software

You might also like