Powerlogic System: Energy Management, Revenue Metering and Power Quality Monitoring
Powerlogic System: Energy Management, Revenue Metering and Power Quality Monitoring
System
Energy management, revenue metering
and power quality monitoring
www.schneider-electric.co.uk
2 schneider-electric.co.uk/metering
Contents Basic energy metering
IEM2000 series, IEM2100 series and IEM3000 series
Product overview 10
Technical Specification 22
Product overview 28
Technical specification 38
Intermediate metering
PM8000 series
Product overview 48
Technical specification 58
Advanced metering
ION7550/7650 series
Product overview 64
Technical specification 74
Product overview 78
Technical specification
88
Multi-circuit metering
BCPM
Product overview 92
Technical specification 106
Communications
Link150, Com’X 200, Com’X 510 and ION7550 RTU
Monitoring software
StruxureWare power management software
schneider-electric.co.uk/metering 3
PowerLogic
System is…
Schneider Electric believes every business can increase productivity while
consuming less and achieving energy savings of 10% to 30%.
PowerLogic technology
Today
forms one part of your
4 schneider-electric.co.uk/metering
Gain energy insight and control
with PowerLogic™
Demand
Power availability and reliability
schneider-electric.co.uk/metering 5
Market segments
Industry Buildings
From finance to engineering, PowerLogic technology Building managers through operations staff can cut
gives industry professionals the energy intelligence and energy and maintenance costs without effecting the
control they need to support strategic decisions and comfort or productivity of their tenants, employees,
establish best energy practices. It will help you reduce students, patients or customers. A PowerLogic system will
operational costs and meet new emissions standards track all utilities and equipment conditions, and enterprise-
without compromising production schedules or product level software will help you analyse and improve electrical
quality. reliability.
Key points are monitored throughout your power You can forecast energy requirements, optimise multi-site
distribution, building and backup systems. Enterprise- contracts and accurately allocate or sub-bill costs. Key
level software helps you maximise the use of your performance indicators help you find and sustain energy
existing energy assets, increase energy efficiency savings, reduce emissions and meet “green” building
and avoid demand or power factor penalties. Use it standards in order to increase asset value and attract or
to uncover hidden power problems that can shorten retain tenants..
equipment life or cause costly downtime.
• tenant sub-billing • power availability
• cost allocation
• cost allocation • demand response / load
• procurement optimisation
• energy efficiency / curtailment
• power factor correction
benchmarking
• procurement optimisation
6 schneider-electric.co.uk/metering
Utilities Critical infrastructure
Today’s energy market is more complex than ever before. PowerLogic technology helps keep your systems operating
Whether you generate, transmit or distribute electricity, continuously and securely with an economical supply
more stakeholders need shared access to timely, accurate of energy. Whether you manage data, communication,
energy data from more exchange points and you need to transportation or environmental services, minimising the risk
maintain power availability and reduce price volatility in of power-related downtime and keeping costs under control
the face of rising demand and transmission congestion. A is a priority.
PowerLogic energy information system helps you meet all
A PowerLogic solution monitors all power and cooling
of these challenges by:
systems and accurately tracks their energy consumption.
Enterprise-level software delivers insightful diagnostics
• Metering all key interchange points with the highest and metrics to help verify the reliability of your backup
possible accuracy systems and maximise the use of existing capacity to
• Improving the quality of power delivered to your defer new capital investments. You can also reveal energy
customers inefficiencies and strengthen energy procurement across
• Essuring the reliability and efficiency of your network multiple sites.
and equipment.
• infrastructure optimisation • energy efficiency
• power quality analysis compliance • cost allocation
From advanced energy and power quality metering • alarming and event notification • procurement optimisation
systems to enterprise-level analytic software, PowerLogic
solutions deliver business-critical information that
conventional metering, SCADA and billing systems
cannot. It gives you the energy intelligence and control
needed to track performance, stay informed of critical
conditions and empower you to make strategic decisions.
It will help you increase reliability, maximise the use of
resources and improve service.
• revenue metering
• power availability and reliability
schneider-electric.co.uk/metering 7
Tools to help you...
PowerLogic Toolkit
Simplifying Specification
Product selector
Build your own specification
Live updates to CPD course calendar
Keep track of most current legislation
Dedicated resource area for tech and spec sheets
10 schneider-electric.co.uk/metering
Applications
Basic energy meters are designed for sub-metering/billing and cost allocation
of energy consumed for each sector, unit, workshop etc. in buildings, industry,
data centres and infrastructure.
schneider-electric.co.uk/metering 11
Product
overview
Basic energy metering
Energy meters designed to gather the data you need to clearly understand your
energy costs. Whether you require a single-phase kWh meters or full-featured,
dual tariff energy meter, Schneider Electric is introducing a NEW iEM2100 series
meter that is the best fit for your customer’s application.
• PowerLogic iEM2000 series
• NEW PowerLogic iEM2100 series
• PowerLogic iEM3000 series
12 schneider-electric.co.uk/metering
BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS
schneider-electric.co.uk/metering 13
BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS
Applications
• To monitor the power consumption of each sector, unit, workshop…
• To manage an electrical installation and optimise your building’s power efficiency
• For business, industrial and residential applications
14 schneider-electric.co.uk/metering
BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS
Conformity of standards
Benefits
• IEC 62053-21
The Acti 9 iEM2000 series meters are economical and easy to • IEC 61557-12
install in all switchboards up to 10 kVA. • EN50470-3
Competitive advantages
• MID compliant (selected models) providing certified
accuracy and data security
• Compact size
• A complete range of energy meters
• Compatible with Acti9 range
Feature selection
iEM2000T iEM2000 iEM2010
Self-powered n n n
Display n/a n n
Width (mm) 18 18 18
schneider-electric.co.uk/metering 15
BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS
Applications
• To monitor the power consumption of each sector, unit, workshop…
• To manage an electrical installation and optimise your building’s power efficiency
• For business, industrial and residential applications
16 schneider-electric.co.uk/metering
BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS
Competitive advantages
• Compact size
• MID compliant (selected models) providing certified
accuracy and data security
• Four quadrant measurement
• Electrical parameter measurement eg. V, I, P, PF
• Onboard Modbus or M-bus communication
• A complete range of energy meters
• Compatible with Acti9 range
Feature selection
iEM2100 iEM2105 iEM2110 iEM2135 IEM2150 iEM2155
Self-powered n n n n n n
Display n n n n n n
Width (mm) 36 36 36 36 36 36
Active Energy
Class 1 Class 1 Class 1 Class 1 Class 1 Class 1
accuracy
Reactive Energy
n/a n/a n/a n/a Class 2 Class 2
accuracy
Four quadrant Energy
measurement
n/a n/a n n n n
Communication
n/a n/a n/a M-bus Modbus RS485 Modbus RS485
protocol
MID for billing
application
n/a n/a n n n/a n
schneider-electric.co.uk/metering 17
BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS
Applications
Cost management applications
• Bill checking to verify that you are only charged for the energy you use
• Sub billing individual tenants for their energy consumption, including WAGES
• Aggregation of energy consumption, including WAGES, and allocating costs per area, per usage, per shift, or
per time within the same facility
• Basic metering of electrical parameters to better understand the behaviour of your electrical distribution system
18 schneider-electric.co.uk/metering
BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS
More than just kWh meters, the Acti 9 iEM3000 series meters provide a full view of both energy consumption and on-site
generation with full four-quadrant measurement of active and reactive energy delivered and received. Additionally, extensive
real-time measurements (V, I, P, PF) give customers greater detail on their energy usage, and multiple tariffs give customers
the flexibility to match the billing structure of their utility.
schneider-electric.co.uk/metering 19
BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS
Self powered n n n n n n n n
Width (18mm module) 5/5/7 5/5/7 5/5 5/5/7 5/5/7 5/5/7 5/5/7 5/5/7
Direct measurement (up to) 63A/-/125A 63A/-/125A 63A/- 63A/-/125A 63A/-/125A 63A/-/125A 63A/-/125A 63A/-/125A
Active Energy measurements class 1/0.5S/1 1/0.5S/1 1/0.5S 1/0.5S/1 1/0.5S/1 1/0.5S/1 1/0.5S/1 1/0.5S/1
Programmable
(Tariff control or 1 1 1 1
Digital inputs WAGES input)
Programmable
(Kwh pulse or KW 1 1 1
Digital outputs overload alarm)
M-bus n
Modbus n n
Communication
protocols
BACnet n
Lon n
Ordering references A9MEM3200 A9MEM3210 A9MEM3215 A9MEM3235 A9MEM3250 A9MEM3255 A9MEM3265 A9MEM3275
How to read table: If a cell contains a single value, that value applies to all meter models identified in the header cell(s). For cells with multiple values, the values
correspond from left to right with the meter models listed from top to bottom for each associated header cell. For example, a cell with
“A / B / C” means A for iEM31xx models, B for iEM32xx models, and C for iEM33xx models
20 schneider-electric.co.uk/metering
NOTES
schneider-electric.co.uk/metering 21
Technical
Specifications
Basic energy metering
22 schneider-electric.co.uk/metering
BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS
Consumption <10 VA
Active energy n n n
iEM2000 dimensions
schneider-electric.co.uk/metering 23
BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS
1 to 1000 pulses /
Pulse output 1 pulse/kwh
n/a kwh or kvarh (30 to n/a n/a n/a
operation (200ms long)
100ms long)
Wiring capacity
6 mm2 4 mm2
(Top)
Wiring capacity
32 mm2 (16 mm2 iEM2100/iEM2105)
(Bottom)
Consumption 2.5 VA 3 VA
Active energy n n n n n n
PB115003
24 schneider-electric.co.uk/metering
BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS
Acti9 iEM3100/iEM3300
Technical specifications
Max current (direct connection) 63A for iEM3100 models, 125A for iEM3300 models
Up to Up to Up to
Pulse output
1000p/kWh 1000p/kWh 1000p/kWh
MID (EN50470-3) n n n n n
Wiring capacity 16 mm² for iEM3100 models, 50 mm2 for iEM3300 models
kWh n n n n n n n n
kVARh n n n n
Active power n n n n n
Reactive power n n n n
Overload alarm n n n n
Hour counter n n n n
schneider-electric.co.uk/metering 25
BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS
Acti9 IEM3200
Technical specifications
iEM3200 iEM3210 iEM3215 iEM3235 iEM3250 iEM3255 iEM3265 iEM3275
Max current (1A/5A CT
6A
connected)
Up to Up to
Pulse output frequency Up to 500p/kWh
500p/kWh 500p/kWh
MID (EN50470-3) n n n n n n
Accuracy class Class 0.5S (IEC 62053-22 and IEC61557-12) Class C (EN50470-3)(1)
kWh n n n n n n n n
kVARh n n n n
Active power n n n n n
Reactive power n n n n
Overload alarm n n n n
Hour counter n n n n
26 schneider-electric.co.uk/metering
BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS
PB105303
PB105306
S0+S0-
93.8
ON
200 /kWh
3.7
45
1.77
103.2
OK ESC 4.06
Reset
Config
63.8
2.51
69.3
126
2.73
4.96
schneider-electric.co.uk/metering 27
Basic
multi-function
metering
28 schneider-electric.co.uk/metering
Applications
Basic multi-function meters are designed for optimising energy use and costs
across your entire organisation. They provide the measurement capabilities
needed to allocate energy usage, perform tenant metering and sub-billing.
schneider-electric.co.uk/metering 29
Product
overview
Basic multi-function metering
A range of meters designed for cost management and simple network management.
Affordable to buy and easy to choose, the highly-capable PowerLogic PM5000 series
meters are designed to provide the best combination of features to match all your
energy cost management needs.
• PowerLogic PM3000
• PowerLogic PM5000
30 schneider-electric.co.uk/metering
schneider-electric.co.uk/metering 31
BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS
PM3000 series
The PowerLogic PM3000 series power meters are a cost-attractive, feature-rich range of DIN rail-
mounted power meters that offers all the measurement capabilities required to monitor an electrical
installation.
Ideal for power metering and network monitoring applications that seek to improve the availability and reliability of your
electrical distribution system, the meters are also fully capable of supporting sub-metering and cost allocation applications.
Applications
Cost management applications
• Bill checking to verify that you are only charged for the energy you use
• Aggregation of energy consumption, including WAGES, and cost allocation per area, per usage,
per shift or per time within the same facility
• Energy cost and usage analysis per zone, per usage or per time period to optimise energy usage
32 schneider-electric.co.uk/metering
BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS
Conformity of standards
Benefits
• IEC 61557-12 • IEC 61000-4-2
Optimise your energy consumption & enable energy efficiency • IEC 62052-11 • IEC 61000-4-3
practices • IEC 62053-21 • IEC 61000-4-4
• Collect and analyse energy consumption data from each area • IEC 62053-22 • IEC 61000-4-5
for each type of load or circuit • IEC 62053-23 • IEC 61000-4-6
• EN 50470-1 • IEC 61000-4-8
• Gain an accurate understanding of business expenses by
• EN 50470-3 • EN55022
allocating the energy-related costs
• IEC 61010-1
• Identify savings opportunities
• Use information to implement actions designed to reduce
energy consumption
Competitive advantages
Connectivity advantages
• Programmable digital input
–– External tariff control signal (4 tariff)
–– Remote Reset partial conter
–– External status like breaker statues
–– Collect WAGES pulses
• Programmable digital output
–– Alarm (PM3255)
–– KWh pulses
• Graphic LCD display
• Modbus RS485 with screw terminals
Multi-tariff capability
The PM3000 series allow to arrange KWh consumption in four
different registers. This can be controlled by
• Digital inputs. Signal can be provided by PLC or utilities
• Internal clock programmable by HMI
• Through communication
This function allows users to:
• Make tenant metering for dual source applications to
differentiate backup source or utility source
• Understand well the consumption during peak time and off-
peak time, weekdays and weekends, holiday and working
days etc
• Follow up feeders consumption in line with utility tariff
rates
schneider-electric.co.uk/metering 33
BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS
Feature selection
PM3200 PM3210 PM3250 PM3255
Performance standard
IEC61557-12 PMD/Sx/K55/0.5 n n n n
General
CT input 1A/5A n n n n
VT input n n n n
Multi-tariff 4 4 4 4
Energy values
Demand value
Data recording
Communication
RS-485 port n n
Modbus protocol n n
34 schneider-electric.co.uk/metering
BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS
PM5000 series
The PowerLogic PM5000 series power meters are the new benchmark in affordable, precision metering.
The ideal fit for high-end cost management applications, providing the measurement capabilities needed to allocate energy
usage, perform tenant metering and sub-billing, pin-point energy savings, optimise equipment efficiency and utilisation, and
perform a high level assessment of the power quality in an electrical network.
Applications
Capable of essential cost management:
• Sub-billing/tenant metering
• Equipment sub-billing
• Energy cost allocation
schneider-electric.co.uk/metering 35
BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS
• Infrastructure
Conformity of standards
Benefits
• IEC61557-12 • IEC 61000-4-3
System integrators’ benefit
• IEC62053-22 • IEC 61000-4-4
• Ease of integration
• IEC62053-24 • IEC 61000-4-5
• Ease of setup
• EN50470-1 • IEC 61000-4-6
• Cost effectiveness
• EN50470-3 • IEC 61000-4-8
• IEC 61010-1 • Etc.
Panel builders’ benefit
• IEC 61000-4-2
• Ease of installation
• Cost effectiveness
• Aesthetically pleasing
• Simplified ordering
• Ease of use
• Precision metering & sub-billing
• Billing flexibility
• Comprehensive, consistent and superior performance
Competitive advantages
• Easy to install and operate
• Easy for circuit breaker monitoring and control
• Direct metering of neutral circuit and calculated ground
current value to avoid overload and resulting outage
(PM556x)
• Power quality analysis??
• Load management combined with alarm and timestamping
• High performance and accuracy
• MID ready compliance for legal billing application
36 schneider-electric.co.uk/metering
BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS
Feature selection
PM5100 PM5300 PM5500
Short reference numbers PM5100 PM5110 PM5310 PM5320 PM5330 PM5340 PM5560 PM5563
Installation
Fast installation, panel mount with b b b b b b b –
integrated display
Multi-tariff – – 4 4 4 4 8 8
Harmonics, individual (odd) up to 15th 15th 31st 31st 31st 31st 63rd 63rd
Relays 0 0 0 0 2 2 0 0
Memory for data logging 256KB 256KB 256KB 256KB 1.1 MB 1.1 MB
Communications
Serial ports with modbus protocol – 1 1 – 1 – 1 1
schneider-electric.co.uk/metering 37
Technical
Specifications
Basic multi-function metering
38 schneider-electric.co.uk/metering
BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS
PM3000 series
Technical specifications
True rms up to the 15th harmonic on three-phase (3P,3P+N) and single-phase AC systems.
Type of measurement
32 samples per cycle
Measurement accuracy
Voltage 0.3% from 50V to 330V (Ph-N), from 80V to 570V (Ph-Ph)
Power factor ±0.005 from 0.5A to 6A with x/5A CTs; from 0.1A to 1.2A with x/1A CTs and from 0.5L to 0.8C
Update rate 1s
Input-voltage characteristics
Input-current characteristics
CT secondary 1A or 5A
Control Power
Input
Digital inputs (PM3255) 11 to 40V DC, 24V DC nominal, <=4mA maximum burden, 3.5kVrms insulation
Output
Digital output (PM3210) Optocoupler, polarity sensitive, 5 to 30V, 15mA max, 3.5kVrms insulation
Solid state relay, polarity insensitive, 5 to 40V, 50mA max, 50Ω max,
Digital outputs (PM3255)
3.5kVrms insulation
schneider-electric.co.uk/metering 39
BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS
PM3000 series
Technical specifications
Mechanical characteristics
Weight 0.26kg
Dimension 90 x 95 x 70mm
Environmental conditions
Pullution degree 2
Electromagnetic compatibility
Level IV (IEC61000-4-2)
Electrostatic discharge
Level IV (IEC61000-4-4)
Immunity to fast transients
Safety
Communication
RS485 port Half duplex, from 9600 up to 38400 bauds, Modbus RTU (double insulation)
Display characteristics
Standard compliance
IEC61557-12, EN61557-12
IEC61010-1, UL61010-1
IEC62052-11, IEC62053-21, IEC62053-22, IEC62053-23
EN50470-1, EN50470-3
40 schneider-electric.co.uk/metering
BASIC MULTI-FUNCTION METERING DIMENSIONS AND CONNECTION
schneider-electric.co.uk/metering 41
BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS
PM5000 series
Technical specifications
PM5100 PM5300 PM5500
Frequency b
Real, reactive, and
Total and per phase Signed, Four Quadrant
apparent power
True Power Factor Total and per phase Signed, Four Quadrant
Displacement PF Total and per phase Signed, Four Quadrant
% Unbalanced I, VL-N, VL-L b
Direct monitoring of neutral current b
Energy values
Accumulated Active, Reactive and Apparent Energy Received/Delivered; Net and absolute; Time Counters
Demand value
Current average Present, Last, Predicted, Peak, and Peak Date Time
Active power Present, Last, Predicted, Peak, and Peak Date Time
Reactive power Present, Last, Predicted, Peak, and Peak Date Time
Apparent power Present, Last, Predicted, Peak, and Peak Date Time
Other measurements
I/O timer b
Operating timer b
Load timer b
42 schneider-electric.co.uk/metering
BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS
Technical specifications
PM5100 PM5300 PM5500
Timestamp resolution in
seconds
1 1 1
Whetting voltage b
Frequency ±0.05%
I nom 5A
Starting current: 5m A
Measured Amps with over range and Starting current: 5mA
Operating range: 50 mA to
Input-current Crest Factor Operating range: 50mA to 8.5A
10 A
(configurable
for 1 or 5 A Withstand Continuous 20A, 10s/hr 50A, 1s/hr 500A
secondary
CTs) Impedance < 0.3 mΩ
100-480 V AC ±10%
100 - 277 V AC L-N / 415 V L-L +/-10%
Operating range CAT III 600V class per IEC
CAT III 300V class per IEC 61010
61010
schneider-electric.co.uk/metering 43
BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS
PM5000 series
Technical specifications
PM5100 PM5300 PM5500
Digital outputs 1 2 2
Optical
Pulse frequency 50 Hz. max. 2.5 kHz. max
outputs
OFF Voltage 0 to 4 V DC
Mechanical characteristics
IP degree of protection (IEC 60529) IP52 front display, IP30 meter body
Dimensions W x H x D [protrusion from cabinet] 96 x 96 x 72mm (77mm for PM5500) (depth of meter from housing mounting flange) [13mm]
Environmental characteristics
Operating
Meter -25 °C to 70 °C
temperature
44 schneider-electric.co.uk/metering
BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS
Technical specifications
Display (Display functions to -25º
-25 °C to +70 °C
with reduced performance)
Polution degree 2
Altitude 2000 m CAT III / 3000 m CAT II 3000 m max. CAT III
Electromagnetic compatibility
Harmonic current emissions IEC 61000-3-2
Safety
PM5100 PM5300 PM5500
Europe CE, as per IEC 61010-1 Ed. 3, IEC 62052-11 & IEC61557-12
Measurement category (Voltage and Current inputs) CAT III up to 400 V L-N / 690 V L-L
Communication
RS 485 port Modbus RTU, Modbus ASCII 2-Wire, 9600,19200 or 38400 baud, Parity - Even, Odd, None, 1 stop bit if parity Odd or Even, 2 stop bits
(7 or 8 bit), JBUS if None; (Optional in PM51x and PM53x)
Firmware and language file update Meter firmware update via the communication ports
Keypad 4-button
Energy pulse
output / Active
Optical, amber LED
alarm indication
(configurable)
schneider-electric.co.uk/metering 45
BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS
PM5500
PM5000 meter parts PM5500 meter parts PM5100 / PM5300 meter parts
A Menu selection buttons E Voltage inputs E Relay output (PM5300 only)
B LED indicators F RS-485 comms F Voltage inputs
C Navigation or menu selections G Digital inputs G Control power
D Maintenance and alarm H Current inputs H Current inputs
notification area I Digital outputs I Status inputs/digital outputs
J Ethernet ports J Communications port: Ethernet
K Control power (PM5300 only) or RS-485)
Please see the Installation Guide for accurate and complete information on the installation of this product.
46 schneider-electric.co.uk/metering
NOTES
schneider-electric.co.uk/metering 47
Intermediate
metering
48 schneider-electric.co.uk/metering
Applications
Intermediate meters are designed for low to high voltage network
management applications for your critical loads, feeders and LV incomers.
These meters seek to improve the availability and reliability of your electrical
system in industrial facilities, data centres, commercial buildings, utilities
networks, or critical power environments. They are fully capable of supporting
billing and cost allocation applications.
schneider-electric.co.uk/metering 49
Product
overview
Intermediate metering
A range of power and energy meters designed for network monitoring
applications like tracking real-time power conditions, monitoring network and
equipment status, load trending, harmonics measurement, and alarm & event
logging & reporting.
Introducing the NEW PowerLogic PM8000 series meters, ensure the reliability and
efficiency of your power-critical facility
50 schneider-electric.co.uk/metering
schneider-electric.co.uk/metering 51
INTERMEDIATE METERING FUNCTIONS AND CHARACTERISTICS
PM8000 Series
The PowerLogic PM8000 series meters are compact, cost-effective multifunction power meters that
will help you ensure reliability and efficiency of your power-critical facility.
Reveal and understand complex power quality conditions. Measure, understand and action insightful data gathered from
your entire power system. Designed for key metering points throughout your energy infrastructure, the PowerLogic PM8000
series meter has the versatility to perform nearly any job you need a meter to do, wherever you need it!
Applications
Ideal for low to high voltage applications in industrial facilities, commercial buildings, utility networks,
or critical power environments.
*PM800 series and ION7300 series were replaced by the NEW PM8000 series in September 2015.
52 schneider-electric.co.uk/metering
INTERMEDIATE METERING FUNCTIONS AND CHARACTERISTICS
Competitive advantages
• ION technology
• MID approved options
• Colour screen
• Multiple communication options
ptember 2015
.
schneider-electric.co.uk/metering 53
INTERMEDIATE METERING FUNCTIONS AND CHARACTERISTICS
Main characteristics
• Precision metering:
–– IEC 61557-12 PMD Sx K70 3000m 0.2 (performance measuring and
monitoring functions).
–– Class 0.2S accuracy IEC 62053-22, ANSI C12.20 Class 0.2 (active energy).
–– Industry leading Class 0.5S* accuracy for reactive energy (IEC 62053-24).
–– Cycle-by-cycle RMS measurements updated every ½ cycle.
–– Full ‘multi-utility’ WAGES metering support.
–– Net metering.
–– Anti-tamper protection seals.
54 schneider-electric.co.uk/metering
INTERMEDIATE METERING FUNCTIONS AND CHARACTERISTICS
Usability
• Easy installation and setup.
–– Panel and DIN rail mounting options, remote display option.
–– Pluggable connectors.
PowerLogic I/O module. –– Free setup application simplifies meter configuration.
• Front panel.
–– Easy to read colour graphic display.
–– Simple, intuitive menu navigation with multi-language (8) support.
schneider-electric.co.uk/metering 55
INTERMEDIATE METERING FUNCTIONS AND CHARACTERISTICS
Adaptability
–– ION™ frameworks allow customisable, scalable applications, object-
oriented programming, compartmentalises functions, and increases
flexibility and adaptability.
–– Applications include: access and aggregate data from Modbus devices
on serial port or across the network (Modbus TCP/IP), logging and/or
processing data by totaling, unit conversion or other calculations, applying
PowerLogic PM8000 series meter with I/O modules.
complex logic for alarming or control operations, data visualisation via web
pages.
56 schneider-electric.co.uk/metering
INTERMEDIATE METERING FUNCTIONS AND CHARACTERISTICS
General
Use on LV and MV systems b
Current accuracy (5A Nominal) 0.1 % reading
Voltage accuracy (57 V LN/100 V LL to 400 V LN/690 V LL) 0.1 % reading
Active energy accuracy 0.2 %
Number of samples/cycle or sample frequency 256
Instantaneous rms values
Current, voltage, frequency b
Active, reactive, apparent power Total and per phase b
Power factor Total and per phase b
Current measurement range (autoranging) 0.05 - 10A
Energy values
Active, reactive, apparent energy b
Settable accumulation modes b
Demand values
Current Present and max. values b
Active, reactive, apparent power Present and max. values b
Predicted active, reactive, apparent power b
Synchronisation of the measurement window b
Setting of calculation mode Block, sliding b
Data recording
Min/max of instantaneous values b
Data logs b
Event logs b
Trending/forecasting b
SER (Sequence of event recording) b
Feature selection Time stamping b
GPS synchronisation (+/- 1 ms) b
Ordering
Description Memory (in Mbytes) 512
reference
Display and I/O
METSEPM8240 96x96 panel mount meter
Front panel display b
Wiring self-test b
METSEPM8243 DIN rail mount meter
Pulse output 1
DIN rail mount meter with remote 27 digital
METSEPM8244 Digital or analogue inputs(max)
display 16 analogue
1 digital
METSEPM82401 MID approved panel mount meter Digital or analogue outputs (max, including pulse output) 8 relay
8 analogue
Accessories Description Communication
Remote display, 3 metre cable, RS 485 port 1
mounting hardware for Ethernet port 2
30mm hole (nut & centering pin), b
METSEPM89RD96 Serial port (Modbus, ION, DNP3)
mounting hardware
for DIN96 cutout (92x92mm) Ethernet port (Modbus/TCP, ION TCP, DNP3 TCP, IEC 61850 (2)
) b
adapter plate Ethernet gateway b
Digital I/O module (6 digital Alarm notification via email b
METSEPM89M2600
inputs & 2 relay outputs) HTTP web server b
Analogue I/O module (4 analogue SNMP with custom MIB and traps for alarms b
METSEPM89M0024 inputs & 2 analogue
outputs) SMTP email b
NTP time synchronisation b
METSEPM8000SK Terminal covers for utility sealing
FTP file transfer b
schneider-electric.co.uk/metering 57
Technical
Specifications
Intermediate metering
58 schneider-electric.co.uk/metering
INTERMEDIATE METERING FUNCTIONS AND CHARACTERISTICS
PM8000 series
Technical specifications
Electrical characteristics
DC 120-300 V DC ±10%
Mechanical characteristics
Integrated Display Model 0.581 kg
DIN rail mounted Model 0.528 kg
Weight
IO modules 0.140 kg
Remote display 0.300 kg
IP 54, UL type 12: Panel mount and Remote display, front.
IP degree of protection
IP 30: Panel mount rear, DIN rail mount, I/O modules.
Panel mount model 96 x 96 x 77.5 mm
DIN model 90.5 x 90.5 x 90.8 mm
Dimensions
Remote display 96 x 96 x 27 mm
IO modules 90.5 x 90.5 x 22 mm
Environmental conditions
Operating temperature -25ºC to +70ºC
schneider-electric.co.uk/metering 59
INTERMEDIATE METERING FUNCTIONS AND CHARACTERISTICS
PM8000 series
Electromagnetic compatibility
Product standards IEC 62052-11 and IEC 61326-1
Immunity to electrostatic
IEC 61000-4-2
discharge
Immunity to conducted
IEC 61000-4-6
disturbances
Immunity to conducted
CLC/TR 50579
disturbances, 2-150kHz
Safety
IEC/EN 61010-1 ed.3, CAT III, 400 VLN / 690 V LL
UL 61010-1 ed.3 and CSA-C22.2 No. 61010-1 ed.3, CAT III, 347 V LN / 600 V LL
Safety Construction
IEC/EN 62052-11, protective class II
Communication (1)
Ethernet to serial line gateway Communicates directly with up to 32 unit load ION slave devices.
Web server Customisable pages, new page creation capabilities, HTML/XML compatible.
Serial port RS 485 Baud rates of 2400 to 115200, pluggable screw terminal connector.
Protocol Modbus, ION, DNP3, IEC 61850, HTTP, FTP, SNMP, SMTP, DPWS, RSTP, NTP, SNTP, GPS protocols.
Firmware characteristics
Down to 1/2 cycle interval burst recording, stores detailed characteristics of disturbances or outages. Trigger recording
High-speed data recording
by a user-defined setpoint, or from external equipment.
Harmonic distortion Up to 63rd harmonic (127th via StruxureWare software) for all voltage and current inputs.
Analyse severity/potential impact of sags and swells: magnitude and duration data suitable for plotting on voltage
Sag/swell detection
tolerance curves per phase triggers for waveform recording, control.
Determine the location of a disturbance more quickly and accurately by determining the direction of the disturbance
Disturbance direction detection relative to the meter. Analysis results are captured in the event log, along with a timestamp and confidence level
indicating level of certainty.
High accuracy of standard speed (1s) and high-speed (1/2 cycle) measurements, including true rms per phase and
total for:
Instantaneous
voltage, current, active power (kW),reactive power (kvar), apparent power (kVA), power factor, frequency, voltage and
current unbalance, phase reversal.
Channel assignments (800 channels via 50 data recorders) configurable for any measurable parameter, including
Load profiling historical trend recording of energy, demand, voltage, current, power quality, or any measured parameter. Trigger
recorders based on time interval, calendar schedule, alarm/event condition, or manually.
Historical trends and future forecasts to better manage demand, circuit loading, and other parameters. Provides
Trend curves average, min, max and standard deviation every hour for last 24 hours, every day for last month, every week for last 8
weeks and every month for last 12 months.
Threshold alarms: adjustable pickup and dropout setpoints and time delays, numerous activation levels possible for a
Alarms given type of alarm, user-defined or automatic alarm threshold settings, user-defined priority levels (optional automatic
alarm setting).
60 schneider-electric.co.uk/metering
INTERMEDIATE METERING FUNCTIONS AND CHARACTERISTICS
Advanced security Up to 16 users with unique access rights. Perform resets, time sync, or meter configurations based on user privileges.
Display characteristics
Integrated or Remote display 320x240 (1/4 VGA) Colour LCD, configurable screens , 5 buttons and 2 LED indicators (alarm and meter status).
Meter setup, communications setup, display setup, date/time/clock setup, alarm setup, language setup, time of use
Setup Menu setup, resets, password setup.
schneider-electric.co.uk/metering 61
INTERMEDIATE METERING FUNCTIONS AND CHARACTERISTICS
90.5
mm (3.56)
(in)
105 78.5
96 (3.09)
(4.13) (3.78) 90.5
(3.56)
111 95 96
(4.37) (3.74) (3.78)
PM8243 dimensions
PM89RD96 dimensions
21 29.8
(0.83) (1.17)
62 schneider-electric.co.uk/metering
NOTES
schneider-electric.co.uk/metering 63
Advanced
metering
64 schneider-electric.co.uk/metering
Applications
Advanced high performance meters are designed for mains or critical loads
on MV/LV networks. They provide analysis of efficiency, losses and capacity,
bill verification, power quality compliance monitoring, problem notification and
diagnosis and control of loads etc.
schneider-electric.co.uk/metering 65
Product
overview
Advanced metering
Power quality meters are classified as advanced meters designed to monitor
service entrances and critical network locations to maximise power availability and
reliability by providing a comprehensive system load profile, power quality and
root cause analyses.
• PowerLogic ION7550/7650
66 schneider-electric.co.uk/metering
schneider-electric.co.uk/metering 67
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS
ION7550/7650 series
Ideal for both energy suppliers and consumers and loaded with advanced functionality for monitoring
key distribution points and sensitive loads, the PowerLogic ION7650/7550 power and energy meter
offers an unmatched feature set including advanced power quality analysis coupled with revenue
accuracy, multiple communications options, web compatibility and control capabilities.
Applications
• Analysis of efficiency, losses and capacity
• Bill verification, cost allocation and sub-metering
• Power quality compliance monitoring
• Problem notification and diagnosis
• Demand or power factor management
• Control of loads, generators or other equipment
68 schneider-electric.co.uk/metering
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS
Benefits
The PowerLogic ION7650/ION7550 meters
help you:
schneider-electric.co.uk/metering 69
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS
Main characteristics
• Anticipate, diagnose and verify to increase efficiency
–– Reveal energy inefficiencies or waste and optimise equipment operation to increase efficiency. Isolate
reliability risks, diagnose power-related equipment issues and verify reliable operation.
• Gateway functionality
–– Access through the meter’s Ethernet port (EtherGate) or telephone network (ModemGate) to Modbus
communicating devices connected to meter serial ports.
–– Detect and capture transients as short as 20µs at 50Hz (17µs at 60 Hz)
–– Identify problems due to short disturbances, e.g. switching of capacitors, etc.
70 schneider-electric.co.uk/metering
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS
Selection guide
1
PE86288
ION7550 ION7650
General
Use on LV and HV systems b b
Demand values
PowerLogic™ ION7550 / ION7650 rear view.
Current Present and max. values b b
Data recording
Min/max of instantaneous values b b
Data logs b b
Event logs b b
Trending/forecasting b b
SER (Sequence of event recording) b b
Time stamping b b
PE86002
schneider-electric.co.uk/metering 71
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS
Part numbers
Item Code Description
Advanced meter with wide-range voltage inputs (57-347V line-neutral or 100-600V line-line), transient detection, data and waveform
M7650 recording, IEC 61000-4-30 Class A & EN50160.Supports ION, IEC 61850 (only for meters with 5MB memory and Ethernet comm
card) Modbus-RTU, and DNP 3.0.
1 Model
Advanced meter with wide-range voltage inputs (57-347V line-neutral or 100-600V line-line), sag/swell detection, data and waveform
M7550
recording. Supports ION, IEC 61850 (only for meters with 5MB memory and Ethernet comm card) Modbus-RTU, and DNP 3.0.
Integrated display with front optical port, 5 MB logging memory, and 512 samples/cycle resolution (ION7650) or 256 samples/cycle
A0
(ION7550).
A1 ION7650 only. Integrated display with front optical port, 5 MB logging memory, and 1024 samples/cycle resolution.
Integrated display with front optical port, 10 MB logging memory, and 512 samples/cycle resolution (ION7650) or 256 samples/cycle
B0
(ION7550).
B1 ION7650 only. Integrated display with front optical port, 10 MB logging memory, and 1024 samples/cycle resolution.
2 Form Factor
Transducer (no display) version, with 5 MB logging memory, and 512 samples/cycle resolution (ION7650) or 256 samples/cycle
T0
(ION7550).
T1 ION7650 only. Transducer (no display) version, with 5 MB logging memory, and 1024 samples/cycle resolution.
Transducer (no display) version, with 10 MB logging memory, and 512 samples/cycle resolution (ION7650) or 256 samples/cycle
U0
(ION7550).
U1 ION7650 only. Transducer (no display) version, with 10 MB logging memory, and 1024 samples/cycle resolution.
G Current Probe Inputs with three Universal Technic 10A clamp on CTs; meets IEC 1036 accuracy
Standard communications plus 10Base-T/100Base-TX Ethernet (RJ45), 56k universal internal modem (RJ11). Ethernet and modem
C1
gateway functions each use a serial communications port.
Standard communications plus 10Base-T/100Base-TX Ethernet (RJ45) and 100BaseFX Ethernet Fiber, 56k universal internal modem
D7
7 Communications (RJ11). Ethernet/modem gateway uses serial port.
E0 Standard communications plus 10Base-T/100Base-TX (RJ45). Ethernet gateway function uses a serial communications port.
Standard communications plus 10Base-T/100Base-TX Ethernet (RJ45) and 100Base-FX (SC male Fiber Optic connection). Ethernet
F1
gateway function uses a serial port.
M1 Standard communications plus 56k universal internal modem (RJ11). Modem gateway function uses a serial port.
E Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 20 mA analogue inputs)
8 I/O K Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 20 mA analogue outputs)
N Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 20 mA analogue inputs and four 0 to 20 mA outputs)
P Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 1 analogue inputs and four -1 to 1 mA analogue outputs)
9 Security 1 Password protected, hardware lockable (enabled/disabled via jumper on comm card)
6 Password protected with security lock enabled, terminal cover and UK OFGEM labels
1 Model.
2 Form factor.
3 Current Inputs.
4 Voltage Inputs.
5 Power supply.
6 System frequency.
M 7 Communications.
8 Inputs/outputs.
Example ION7650 product part number. 9 Security.
10 Special order.
72 schneider-electric.co.uk/metering
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS
ION75XX/76XX Accessories
Communication Card for ION7550/7650 Ordering reference
Standard Comms: 1 RS232/RS485 port (COM1), 1 RS485 port (COM2), Front optical port (COM3) P765CA0A
Standard Comms: 1 RS232/RS485 port (COM1), 1 RS485 port (COM2), Front optical port (COM3), tropicalisation treatment
P765CA0C
applied
Standard plus Ethernet (10/100BASE-T), 56k universal internal modem (RJ11; shares COM3) P765CC1A
Standard plus Ethernet (10/100BASE-T), 56k universal internal modem (RJ11; shares COM3), tropicalisation treatment applied P765CC1C
Standard plus Ethernet (10/100BASE-T, 100BASE-FX), 56k internal modem (RJ11) P765CD7A
Standard plus Ethernet (10/100BASE-T, 100BASE-FX), 56k internal modem (RJ11), tropicalisation treatment applied P765CD7C
Standard plus 56k universal internal modem (RJ11; shares COM3) P765CM1A
Standard plus 56k universal internal modem (RJ11; shares COM3),tropicalisation treatment applied P765CM1C
four 0 to 20 mA analogue inputs, four 0 to 20 mA analogue outputs & 8 digital inputs P760ANA
four 0 to 20 mA analogue inputs, four 0 to 20 mA analogue outputs & 8 digital inputs,tropicalisation treatment applied P760ANC
four 0 to 1 analogue inputs, four -1 to 1 mA analogue outputs & 8 digital inputs. P760APA
four 0 to 1 analogue inputs, four -1 to 1 mA analogue outputs & 8 digital inputs,tropicalisation treatment applied P760APC
ION7550/7650 remote display kit, includes display, 24 VDC power supply and Ethernet cable, Schneider Electric branded M765RDPS
10A/1 VAC Universal Technic Clamp On Current Probe (Price per probe) M1UB10A1V-10A
1000A/1 VAC Universal Technic Clamp On Current Probe (Price per probe) P32UEP813-1000A
3000A/1 VAC Universal Technic Clamp On Current Probe (Price per probe) P32UEP815-3000A
300A/0.333 VAC Magnelabs Split Core Current Probe (Price per probe) SCT1250-300-300A
schneider-electric.co.uk/metering 73
Technical
Specifications
Advanced metering
74 schneider-electric.co.uk/metering
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS
ION7550/ION7650 series
Technical specifications
Electrical characteristics
Type of measurement True rms to 1024 samples per cycle (ION7650)
Measurement Current and voltage ±0.01% of reading + ±0.025% of full scale
accuracy Power ±0.075% of reading + ±0.025% of full scale
Frequency ±0.005Hz
Power factor ±0.002 from 0.5 leading to 0.5 lagging
Energy: IEC62053-22 0,2S, 1A and 5A
Data update rate 1/2 cycle or 1 second
Input-voltage Measurement range Autoranging 57V through 347V LN / 600V LL
characteristics Impedance 5 MW/phase (phase - Vref)
Frequency measurement
42 to 69Hz
range
Rated nominal current 1A, 2A, 5A, 10A
Input-current
characteristics 0.005 - 20 A autoranging (standard range)
Measurement range
0.001 - 10 A autoranging (optional range)
500 A rms for 1 s, non-recurring (5A)
Permissible overload
50 A rms for 1s, non-recurring (1A)
0.002 W per phase (5A)
Impedance
0.015 W per phase (1A)
0.05 VA per phase (5 A)
Burden
0.015 VA per phase (1 A)
AC 85-240 V AC ±10% (47-63 Hz)
DC 110-300 V DC ±10%
DC low voltage (optional) 20-60 V DC ±10%
Power supply
Ride-through time 100 ms (6 cycles at 60 Hz) min.
Standard: typical 20 VA, max 45 VA
Burden
Low voltage DC: typical 15 VA, max 20 VA
8 digital inputs (120 V DC)
Input/outputs(1) Standard 3 relay outputs (250 V AC / 30 V DC)
4 digital outputs (solid state)
8 additional digital inputs
Optional
4 analogue outputs, and/or 4 analogue inputs
Mechanical characteristics
Weight 1.9 kg
Integrated display, front: IP 50; back: IP 30
IP degree of protection (IEC 60529)
Transducer unit (no display): IP 30
Standard model 192 x 192 x 159 mm
Dimensions
TRAN model 235.5 x 216.3 x 133.1 mm
Environmental conditions
Operating Standard power supply -20 to +70 ºC
temperature Low voltage DC supply -20 to +50 ºC
Display operating range -20 to +60 ºC
Storage
Display, TRAN -40 to +85 ºC
temperature
Humidity rating 5 to 95% non-condensing
Installation category III (2000m above sea level)
Dielectric withstand As per EN 61010-1, IEC 62051-22A(2)
Electromagnetic compatibility
Electrostatic discharge IEC 61000-4-2
Immunity to radiated fields IEC 61000-4-3
Immunity to fast transients IEC 61000-4-4
Immunity to surges IEC 61000-4-5
Conducted and radiated emissions CISPR 22
Safety
Europe IEC 61010-1
Communication
RS 232/485 port (1)
Up to 115,200 bauds (57,600 bauds for RS 485), ION, DNP 3.0, Modbus, GPS, EtherGate, ModemGate, Modbus Master
Infrared port(1) ANSI type 2, up to 19,200 bauds, ION, Modbus, DNP 3.0
Fibre-optic Ethernet link 100 Base FX, SC duplex connector, 1300 nm, FO multimode with gradient index 62.5/125 µm or 50/125 µm, 2000 m link
(1) Consult the ION7550 / ION7650 installation guide for complete specifications. (2) IEC 62051-22B with serial ports only.
schneider-electric.co.uk/metering 75
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS
Communication (cont.)
PE86004
Firmware characteristics
Display characteristics
Integrated display Back lit LCD, configurable screens
Languages English, French, Spanish, Russian
Example showing instantaneous values and alarm. Notations IEC, IEEE
(1) Consult the ION7550 / ION7650 installation guide for complete specifications.
(2) IEC 62051-22B with serial ports only.
76 schneider-electric.co.uk/metering
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS
ION7550/ION7650 dimensions
Front-panel mounting
ION7550 and ION7650 meter can have integrated or remote display. The meter with
integrated display is designed to fit DIN standard 192 cutout (186 mm by 186 mm) . The
remote display is intalled through a circular cutout (22.5 mm diameter) at the panel door and
it has a front and a back module that is connected to the meter mounted in a DIN rail at the
back.
schneider-electric.co.uk/metering 77
Advanced utility
metering
78 schneider-electric.co.uk/metering
Applications
Power quality and revenue meters are designed for utility network monitoring,
eg. transmission and distribution network monitoring.
schneider-electric.co.uk/metering 79
Product
overview
Advanced utility metering
Revenue and power quality meters designed for precision metering at key
transmission network inter-ties, distribution substations and service entrances to
optimise power reliability and energy efficiency in utility smart grids.
• PowerLogic ION8800
80 schneider-electric.co.uk/metering
schneider-electric.co.uk/metering 81
ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS
ION8800 series
Providing high accuracy and a wide range of features for transmission and distribution metering,
the PowerLogic ION8800 advanced revenue and power quality meter has the flexibility to change
along with your needs. The meter provides the tools necessary to:
• Manage energy procurement and supply contracts
• Perform network capacity planning and stability analysis’
• Monitor power quality compliance, supply agreements, and regulatory requirements
Applications
• Transmission and distribution metering
• Revenue metering
• Extensive power quality monitoring and analysis
• Power quality compliance monitoring
• Digital fault recording
• Instrument transformer correction
82 schneider-electric.co.uk/metering
ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS
schneider-electric.co.uk/metering 83
ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS
Main characteristics
• IEC 19-inch rack mount design to DIN 43862 standard
–– Use Essailec connectors with common measurement and energy pulsing pin-out to easily retrofit into
existing systems.
• Accurate metering
–– Interconnection points on medium, high, and ultra-high voltage networks are in compliance with IEC
62053-22/23 Class 0,2S.
• Complete communications
–– Use the IEC1107 optical port or the optional communications module that supports concurrent Ethernet,
serial, and modem communications.
• Software integration
–– Easily integrate the meter with StruxureWare Power Monitoring (ION Enterprise) or other utility software;
MV-90, Pacis and third-party SCADA packages.
84 schneider-electric.co.uk/metering
ADVANCED UTILITY METERING
PE86001
FUNCTIONS AND CHARACTERISTICS
Selection guide
ION8800A
ION8800C
ION8800B
General
Use on LV, MV and HV systems b b
Current accuracy 0.1 % 0.1 %
Voltage accuracy 0.1 % 0.1 %
Power accuracy 0.2 % 0.2 %
Samples/cycle 1024 1024
Instantaneous rms values
Current, voltage, frequency (Class 0,2S) b b
Active, reactive, apparent power Total and per phase b b
Power factor Total and per phase b b
Current measurement range 0.001 - 10A 0.001 - 10A
Current measurement range 0.001 - 10A 0.001 - 10A
PowerLogic ION8800 meter
Energy values
1 Optional communications module. Active, reactive, apparent energy b b
2 Essailec connectors. Settable accumulation modes b b
3 Internal modem.
Demand values
4 Optional Ethernet communications.
Current b b
5 Selectable RS 485 serial port.
6 Selectable RS 232 or RS 485 serial port. Active, reactive, apparent b b
7 Ground terminal. Predicted active, reactive, apparent b b
Demand modes (block, sliding, thermal, predicted) b b
Power quality measurements
Detection of voltage dips (sags) and swells 10 ms 10 ms
Symmetrical components: zero, positive, negative b -
Transient detection, microseconds (50 Hz) 20 (1) 20 (1)
Harmonics: individual, even, odd, total up to 63rd 63rd
Harmonics: magnitude, phase and inter-harmonics 50th 40th
EN 50160 compliance b
IEC 61000-4-30 class A b
IEC 61000-4-30 class S b (2)
IEC 61000-4-15 (Flicker) b -
Configurable for IEEE 519 - 1992, IEEE1159-1995 b(1) -
Programmable (logic and math functions) b b
Data recording
Min/max logging for any parameter b b
PE86235
schneider-electric.co.uk/metering 85
ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS
Part numbers
Item Code Description
1 Model M8800 ION8800 IEC/DIN 43862 19” rack mount energy and power quality meter.
A Class A power quality analysis, waveforms and transient capture with 1024 samples/cycle.
C (I1-I3): Configured for 5 A nominal, 10 A full scale, 14 A fault capture, 0.001 A starting current.
4 Current Inputs
E (I1-I3): Configured for 1 A nominal, 10 A full scale, 14 A fault capture, 0.001 A starting current.
5 Voltage Inputs 0 (V1-V3): Autoranging (57-288 VAC L-N or 99-500 VAC L-L)
6 Power Supply B Single phase power supply: 85-240 VAC ±10% (47-63 Hz) or 110-270 VDC.
Z0 No communications module - meter includes Base Onboard I/O and comms (see below for details).
C1 Standard communications plus 10Base-T Ethernet (RJ45), 56 k universal internal modem (RJ11).
Communications
Standard communications plus 10Base-T Ethernet (RJ45) / 10Base-FL Ethernet Fiber, 56 k universal internal modem
8 module (field D1
(RJ11).
serviceable)
E0 Standard communications plus 10Base-T Ethernet (RJ45).
F0 Standard communications plus 10Base-T Ethernet (RJ45) / 10Base-FL (ST male Fiber Optic connection).
A Base option AND 8 Form A digital outputs (2), 1 RS-485 (COM2) port (1).
Onboard B Base Option AND 8 Form A digital outputs (2), 3 digital inputs (20-56 VDC/AC).
I/O and
communications
9 C Base Option AND 8 Form A digital outputs (2), 3 digital inputs (80-280 VDC/AC).
(not field
serviceable, part
of base unit) D Base Option AND 1 IRIG-B time sync port , 1 RS-485 port (COM2), 3 digital inputs (20-56 V DC/AC)
(2)
.
(1)
E Base Option AND 1 IRIG-B time sync port , 1 RS-485 port (COM2), 3 digital inputs (80-280 V DC/AC)
(2) (1)
.
A None.
11 Special Order
C Tropicalisation treatment applied.
1 Model.
2 Feature set.
3 Memory / form factor.
4 Current Inputs.
5 Voltage inputs.
6 Power supply.
7 System frequency.
8 Communications.
9 Onboard inputs/outputs.
10 Security.
11 Special order.
(1) Channel COM2 is available on the port at the back of the meter OR on the Comm Module
(if installed). You must select which connectors your communications wiring is connected to during meter setup.
(2) All Onboard I/O and Comms (Base Option) options include: 4 Form C solid-state digital outputs, 1 Form C mechanical relay output, one IEC 1107 optical
communications port,
two IEC 1107 style optical pulsing ports.
86 schneider-electric.co.uk/metering
ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS
ION8800 Accessories
Communication Card for ION8800 Ordering reference
Std. comms: 1 RS-232/RS-485 port, **1 RS-485 port (COM2), tropicalisation treatment applied P880CA0C
Std. comms AND 10BASE-T Ethernet (RJ45), 56k universal internal modem (RJ11) P880CC1A
Std. comms AND 10BASE-T Ethernet (RJ45), 56k universal internal modem (RJ11), tropicalisation treatment applied P880CC1C
Std. comms AND 10BASE-T Ethernet (RJ45) / 10BASE-FL Ethernet Fiber, 56k universal internal modem (RJ11) P880CD1A
Std. comms AND 10BASE-T Ethernet (RJ45) / 10BASE-FL Ethernet Fiber, 56k universal internal modem (RJ11), tropicalisation
P880CD1C
treatment applied
Std. comms AND 10BASE-T Ethernet (RJ45), tropicalisation treatment applied P880CE0C
Std. comms AND 10BASE-T Ethernet (RJ45) / 10BASE-FL (ST Fiber Optic connection) P880CF0A
Std. comms AND 10BASE-T Ethernet (RJ45) / 10BASE-FL (ST Fiber Optic connection), tropicalisation treatment applied P880CF0C
Std. comms AND 56k universal internal modem (RJ11), tropicalisation treatment applied P880CM1C
Replacement batteries for the ION 8600 or ION 8800, quantity 10 BATT-REPLACE-8XXX
IEC/DIN 34862 19” Rack with female mating voltage/current and I/O blocks unassembled. RACK-8800-RAW
IEC 61107 compliant Optical Probe (DB-9) for use with ION 8800 meters IEC-OPTICAL-PROBE
schneider-electric.co.uk/metering 87
Technical
Specifications
Advanced utility metering
88 schneider-electric.co.uk/metering
ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS
ION8800 series
Technical Specification Technical Specification
Electrical characteristics
True rms
Type of measurement
1024 samples per cycle
Current and voltage 0.1 %
Power 0.2 %
Measurement
Frequency ±0.005 Hz
accuracy
Power factor 0.1%
Energy IEC 62053-22/23 Class 0.2 S
Data update rate ½ cycle or 1 second
Inputs U1, U2, U3, Uref
Input-voltage Measurement range 57-288 LN VAC rms (99-500 LL VAC rms)
characteristics Dielectic withstand 3320 VAC rms
Impedance 5 MW /phase (phase-Uref/Ground)
Rated nominals 5 A, 1 A, 2 A
Input-current Permissible overload 200A rms for 0.5s, non-recurring (IEC 62053-22)
characteristics Impedance 10 mW /phase
Burden 0.01 VA per phase (1A), 0.25 VA per phase (5 A)
AC 85 - 240 VAC (+/- 10%), 47-63 Hz
DC 110 - 270 VDC (+/- 10%)
Typical (without comm module): 13 VA, 8 W Typical (with comm module): 19 VA, 12 W
Burden
Power supply Max (without comm module): 24 VA, 10 W Max (with comm module): 32 VA, 14 W
Mechanical alarm relay 1 Form C digital output (250 V AC / 125 V DC, 1 A AC / 0.1 A DC max)
3 Solid state digital inputs (low-voltage inputs 15 to 75 V AC/DC; high-voltage inputs 75 to 280 V AC/DC; 3 mA
Digital inputs
max.)
(1) Consult the ION7550 / ION7650 installation guide for complete specifications. (2) IEC 62051-22B with serial ports only.
schneider-electric.co.uk/metering 89
ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS
Technical Specification
Communication
IEC 1107 optical port 2/4 wires, up to 19200 bauds
Up to 57600 bauds, direct connection to a PC or
RS 485 port modem, protocols: ION, Modbus RTU, Modbus Master,
DNP 3.0, GPSTRUETIME/DATUM, DLMS
90 schneider-electric.co.uk/metering
ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS
ION8800 dimensions
schneider-electric.co.uk/metering 91
Multi-circuit
metering
92 schneider-electric.co.uk/metering
Applications
This is an integrated solution for monitoring multi-circuits and mains by using a
single meter. The meter is designed for use in both new build and retrofit and
is used for critical power operations in data centres and energy management
in buildings.
schneider-electric.co.uk/metering 93
Product
overview
Multi-circuit metering
The ideal solution for data centre managers, energy or facility managers,
engineers and operational executives who are responsible for delivering power to
critical applications.
In corporate and hosted data centre facilities, this technology helps you plan
and optimise the critical power infrastructure to meet the demands of continuous
availability.
• PowerLogic BCPM
94 schneider-electric.co.uk/metering
schneider-electric.co.uk/metering 95
MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS
PowerLogic BCPM
The PowerLogic BCPM is a highly accurate, full-featured metering product designed for the unique,
multi-circuit and minimal space requirements of a high performance power distribution unit (PDU) or
remote power panel (RPP).
It offers class 1 (1%) power and energy system accuracy (including 50A or 100A CTs) on all branch channels. The BCPM
monitors up to 84 branch circuits and the incoming power mains to provide information on a complete PDU. Full alarming
capabilities ensure that potential issues are dealt with before they become problems.
Applications
• Maximise uptime and avoid outages
• Optimise existing infrastructure
• Improve power distribution efficiency
• Track usage and allocate energy costs
• Enable accurate sub-metering
96 schneider-electric.co.uk/metering
MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS
Competitive advantages
• Fit any PDU or RPP design for both new and retrofit projects
• Class 1.0 system accuracy
• Ethernet communication
schneider-electric.co.uk/metering 97
MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS
Main characteristics
• Monitor up to 84 branch circuits with a single BCPM.
• Ideal for installation in both new PDUs and retrofit projects
• New installations:
–– BCPM with solid core CTs monitors up to 84 branch circuits using 2 or 4 CT
strips. Solid core CTs are rated to 100 A CTs and are mounted on strips to
simplify installation. CT strips are available with 12, 8 or 21 CTs per strip on
18 mm spacings. 21 CT strips with 3/4” or 1” spacings are also available.
• Retrofit projects:
–– BCPMSC with split core CTs is ideal for retrofits. Any number of split core
CTs, up to 84 maximum, can be installed with a single BCPM. Three sizes
of CT are supported (50 A, 100 A, and 200 A) and all three CT sizes can
be used on a single BCPM. Adapter boards with terminals for split-core
CTs can be mounted using DIN-rail, Snaptrack or on a common mounting
plate with the main board (42 ch Y63 models only).
• IEC Class 1 metering accuracy
–– Accurately monitor very low current levels, down to a quarter-Amp.
–– Easily differentiate between the flow of low current and a trip where no
current flows.
• Class 1.0 system accuracy for Revenue Grade measurements
–– Branch Power and Energy measurements fully meet ANSI and IEC class
1 accuracy requirements with 50 or 100 Amp CTs included. No need
to de-rate meter branch accuracy to allow for CTs. Voltage and current
measurement accuracy is 0.5% and currents are measured down to 50mA.
Easily differentiate between the flow of low current and a trip where no
current flows.
• Designed to fit any PDU or RPP design
–– Lowers your total installation costs as well as the cost per meter point by
supporting both new and retrofit installations.
• New models with integrated Ethernet offer broad protocol support
–– All models integrate easily into existing networks using Modbus RTU
communications over an RS-485 serial link. BCPME and BCPMSCE models
offer integrated Ethernet and add support for Modbus TCP, BACnet IP,
BACnet MS/TP and SNMP. An optional external gateway can be added to
all other models to add the same capability.
• Compatible with PowerLogic power monitoring software
–– Easily turn the large amount of data collected by the devices into useful
decision-making information.
• Flexible Configuration capability
–– Set the ordering and orientation of CT strips, assign individual CT size and
phases, support for 1, 2, and 3-pole breakers in any configuration.
98 schneider-electric.co.uk/metering
MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS
General
Use on LV systems b b
Branch circuits b b
Current b b
Alarming
Alarms b b
Power supply
90-277 100-277
AC version
V ac V ac
Communication
RS 485 port b b
Modbus protocol b b
Ethernet Port 1* b
BACnet IP protocol 1* b
SNMP protocol 1* b
schneider-electric.co.uk/metering 99
MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS
100 schneider-electric.co.uk/metering
MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS
Example BCPMSC with split core CTs part number. Advanced - Monitors power and energy per
circuit and mains, Modbus RTU only (add
A
E8951 for other protocols), Meter Main Board
1 Model. comes on an aluminum mounting plate
2 Feature set.
3 Number of circuits. Intermediate - Monitors current per circuit,
4 Brand. power and energy per mains, Modbus RTU
B only (add E8951 for other protocols), Meter
Main Board comes on an aluminum mounting
2 Feature set plate
*The BCPMSC models with 1, 2 or Y63 as the number of circuits DO NOT INCLUDE
ANY branch CTs or ribbon cables (they include only the Main board and adapater board
assemblies) . These models are provided to allow users to order a specific combination of
CT quantities, CT sizes, CT lead lengths and ribbon cable styles and lengths. The CTs and
cables must be ordered separately.
Models with more than 2 as the number of circuits include 50A branch CTs with 2 meter
leads and 1.8M round ribbon cables.
The PowerLogic BCPMSC uses .333 VAC output split-core CTs for the auxiliary inputs. These
CTs are ordered separately from the BCPM.
schneider-electric.co.uk/metering 101
MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS
BCPM part numbers for solid and split core CTs (contd.)
BCPM with split core CTs
Part number Description
42-circuit solid-core power & energy meter, 100A CTs (2 strips), ¾”
BCPMA042S
spacing
24-circuit solid-core power & energy meter, 100A CTs (2 strips), 18mm
BCPMA224S
spacing
36-circuit solid-core power & energy meter, 100A CTs (2 strips), 18mm
BCPMA236S
spacing
Flat ribbon cable
42-circuit solid-core power & energy meter, 100A CTs (2 strips), 18mm
BCPMA242S
spacing
48-circuit solid-core power & energy meter, 100A CTs (4 strips), 18mm
BCPMA248S
spacing
72-circuit solid-core power & energy meter, 100A CTs (4 strips), 18mm
BCPMA272S
spacing
84-circuit solid-core power & energy meter, 100A CTs (4 strips), 18mm
BCPMA284S
spacing
102 schneider-electric.co.uk/metering
MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS
BCPM part numbers for solid and split core CTs (contd.)
BCPM with split core CTs
Part number Description
42-circuit split-core power and energy meter, CTs and cables sold
BCPMSCA1S
separately
84-circuit split-core power and energy meter, CTs and cables sold
BCPMSCA2S
separately
BCPMSCA30S 30-circuit split-core power and energy meter, (30) 50A CTs & (2) 4’ cables
BCPMSCxY63S 42-circuit split-core models come with the main
board, (2) adapter boards and ribbon cables all mounted on a
backplate, to simplify installation. BCPMSCA42S 42-circuit split-core power and energy meter, (42) 50A CTs & (2) 4’ cables
BCPMSCA60S 60-circuit split-core power and energy meter, (60) 50A CTs & (4) 4’ cables
42-circuit split core power and energy meter, all boards on backplate,
BCPMSCAY63S
CTs and cables sold separately
PE86183
84-circuit split-core power and energy meter, with (84) 50A CTs & (4) 4’
BCPMSCA84S
cables
42-circuit split-core power and energy meter w/Ethernet, CTs and cables
BCPMSCE1S
sold separately
84-circuit split-core power and energy meter w/Ethernet, CTs and cables
BCPMSCE2S
sold separately
30-circuit split-core power and energy meter w/Ethernet, (30) 50A CTs &
BCPMSCE30S
(2) 4’
42-circuit split-core power and energy meter w/Ethernet, (42) 50A CTs &
BCPMSCE42S
PowerLogicTM LVCT0xxxxS Split-core Low-voltage (1/3V) CTs for Aux (2) 4’ cables
inputs (Mains) are ideal for retrofit applications
60-circuit split-core power and energy meter w/Ethernet, (60) 50A CTs &
BCPMSCE60S
(4) 4’ cables
84-circuit split-core power and energy meter w/Ethernet, (84) 50A CTs &
PB113652
BCPMSCE84S
(4) 4’ cables
The PowerLogicTM BCPM uses .333 VAC output split-core CTs for the auxiliary inputs.
These CTs are ordered separately from the BCPM.
PB113657
PB113658
schneider-electric.co.uk/metering 103
MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS
BCPMSCCT0 BCPM 50A split core CTs, Quantity 6, 1.8 m lead lengths
BCPMSCCT1 BCPM 100A split core CTs, Quantity 6, 1.8 m lead lengths
BCPMSCCT3 BCPM 200A split core CTs, Quantity 1, 1.8 m lead lengths
BCPMREPAIR CT repair kit for solid core BCPM (includes one CT)
H6803R-0100 Additional 100A split core CT for use with solid core repair kit
LVCT00202S 200A 30 mm x 31 mm
LVCT00302S 300A 30 mm x 31 mm
LVCT00403S 400A 62 mm x 73 mm
LVCT00603S 600A 62 mm x 73 mm
LVCT00803S 800A 62 mm x 73 mm
LVCT20100S 100A 10 mm
LVCT20202S 200A 25 mm
LVCT20403S 400A 31 mm
104 schneider-electric.co.uk/metering
NOTES
schneider-electric.co.uk/metering 105
Technical
Specifications
Multi-circuit metering
106 schneider-electric.co.uk/metering
MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS
BCPM
Technical specifications
Electrical characteristics
Type of measurement
Data update rate 1.8 seconds (Modbus), 14 seconds (BACnet) 20 sec (SNMP)
Auxiliary CT Current Input Range 0-0.333V; CTs must be rated for use with Class 1 voltage inputs
Mechanical characteristics
Weight 1.5 kg
Environmental conditions
Operating temperature 0 to 60ºC
Safety
Europe IEC 61010
Communication
Baud rate: configured via Web-server. Baud selectable: 9600, 19200, 38400. Parity selectable: Even, Odd or None.
RS 485 (A models)
2-wire RS-485.
Protocols Modbus RTU on all models, BCPME models also support Modbus TCP, SNMP, BACnet IP & BACnet MS/TP
Firmware characteristics
Detection of over-voltage/under-
User-defined alarm thresholds for over-voltage and under-voltage detection
voltage
Four alarm levels: high-high, high, low and low-low (users define the setpoints for each). Each alarm has a latching
Alarms status to alert the operator that an alarm has previously occurred. High and Low alarms have instantaneous status to let
the operator know if the alarm state is still occurring.
schneider-electric.co.uk/metering 107
MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS
BCPM cont’d
1/3 V low-voltage CT (LVCT) for Mains - Technical specifications
Electrical characteristics
Environmental conditions
0ºC to 70ºC (LVCT0xxxx0S/1S)
-15ºC to 60ºC (LVCT0xxxx2S/3S/4S less than 2400A)
Operating temperature
-15ºC to 60ºC (LVCT02404S [2400A])
-40ºC to 85ºC (LVCT2xxxx0S/2S/3S [solid-core])
108 schneider-electric.co.uk/metering
MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS
1.0” 211 mm
(26 mm)
1.0” 2.75”
(26 mm) (70 mm) 146 mm
122 mm
4.6”
(117 mm)
228 mm
schneider-electric.co.uk/metering 109
E31CT05050Amp
E31CT0 Amp
DD AA
A A==1.0”
1.0”(26(26mm)
mm)
BB CC B B==0.5”
0.5”(11(11mm)
mm)
EE
C=C =0.4”
0.4”(10(10mm)
mm)
MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS
D D==0.9”
0.9”(23(23mm)
mm)
E=E =1.6”
1.6”(40(40mm)
mm)
E31CT1100
E31CT1 100Amp
Amp
DD AA
A A==1.5”
1.5”(39(39mm)
mm)
B B==0.8”
0.8”(20(20mm)
mm)
50A-200A Split-Core CT dimensions BB CC EE C=C =0.7”
0.7”(16(16mm)
mm)
D D==1.6”
1.6”(40(40mm)
mm)
E=E =2.1”
2.1”(53(53mm)
mm)
DD AA E31CT3200
E31CT3 200Amp
Amp
A A==1.5”
1.5”(39(39mm)
mm)
B B==1.25”
1.25”(32(32mm)
mm)
BB CC
EE C=C =1.25”
1.25”(32(32mm)
mm)
D D==2.5”
2.5”(64(64mm)
mm)
E=E =2.8”
2.8”(71(71mm)
mm)
110 schneider-electric.co.uk/metering
MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS
Mains monitoring
(CTs ordered separately)
BCPM PCB
schneider-electric.co.uk/metering 111
Communications
112 schneider-electric.co.uk/metering
COMMUNICATIONS FUNCTIONS AND CHARACTERISTICS
Applications
This is a part of your metering solution which provides an interface between
energy monitoring software and your metering points via GPRS, wired
connection and wifi. We also offer the option of an integrated gateway-server
which provides all-in-one energy management solution. They are fully capable
of supporting StruxureWare Power Monitoring software.
schneider-electric.co.uk/metering 113
Product
overview
Communications
Data loggers, gateways and remote terminal units help measured data reach the
power monitoring software for analyses.
114 schneider-electric.co.uk/metering
COMMUNICATIONS FUNCTIONS AND CHARACTERISTICS
* Gateway EGX100 was replaced by new Link150 in October 2015 and gateway-sever EGX300 was
replaced by new Com'X 510 in June 2015.
schneider-electric.co.uk/metering 115
COMMUNICATIONS FUNCTIONS AND CHARACTERISTICS
Serial link
With communication technology, it is no longer necessary to be physically present at the site to
access information. Data is transmitted by networks.
In all architectures, the communication interface serves as the link between the installation devices and the PC
running the operating software. It provides the physical link and protocol adaptation. Adaptation is required
because the communication systems used by the PC (Modbus via RS232 and/or Ethernet) are generally not those
used by the installation devices (e.g. the Modbus protocol via RS485).
Dedicated application software prepares the information for analysis under the best possible conditions.
Link150
serial slave mode
Switchboard-data acquisition and monitoring make it possible to anticipate events. In this way,
they reduce customer costs in terms of operation, maintenance and investment.
116 schneider-electric.co.uk/metering
COMMUNICATIONS FUNCTIONS AND CHARACTERISTICS
Ethernet link
Using modern Web technologies, the operator can access information from monitoring and
protection devices using any PC connected to the network, with all the required security.
The Ethernet Modbus-Ethernet gateway* or the integrated gateway-servers* provide connectivity between
Modbus RS485 and Ethernet Modbus TCP/IP.
The services available with these technologies considerably simplify the creation, maintenance and
operation of these supervision systems.
The application software is now standardised: The first step in this approach is the
the web interface into the system does not integrated gateway-server with HTTP pages.
require custom web pages to be created. Power management software (StuxureWare
It is personalised by simply identifying the Power Monitoring Expert and StruxureWare
components in your installation and can be PowerSCADA Expert), running on a PC, provide
used as easily as any internet application. broader coverage for more specific needs.
schneider-electric.co.uk/metering 117
COMMUNICATIONS FUNCTIONS AND CHARACTERISTICS
Applications
• Energy management
• Power distribution
• Building automation
• Factory automation
118 schneider-electric.co.uk/metering
COMMUNICATIONS FUNCTIONS AND CHARACTERISTICS
PowerLogic
Architecture software
Link150
Security
• Secure user interface including user’s name and password for login
• Advanced security features to allow users to specify which Modbus TCP/IP master devices may access attached serial
slave devices
• Modbus TCP/IP filtering feature
• Allows user to specify the level of access for each master device as Read-only or Full access
• Web pages provide easy configuration and setup
schneider-electric.co.uk/metering 119
COMMUNICATIONS FUNCTIONS AND CHARACTERISTICS
Com’X 200
A highly flexible plug-and-play Energy Server Com’X 200 collects and stores WAGES consumptions
and environmental parameters such as temperatures, humidity and CO2 levels in a building. Data is
periodically transmitted as a report to an internet database server for further processing. The Energy
Server Com’X 200 not only reduces your technical complexity, but help to manage your energy.
Applications
The quickest path to multi-site energy management and
on-line services
• Delivers batches of data ready to process by StruXureware solutions and services
• Publishes logged data to the Schneider Electric cloud or another hosted platform
120 schneider-electric.co.uk/metering
COMMUNICATIONS FUNCTIONS AND CHARACTERISTICS
Conformity of standards
• EN60950
Architecture
Power
PowerView Ethernet or Monitoring
Remote Internet Wi-Fi LAN Expert
GPRS
Com’X 200
2. Connect
Ethernet |
Modbus TCP
Temperature
sensors
1.Measure
Modbus multi-meters
Circuit-breakers
Analogue Pulse energy meters
sensors
with 4-20 mA
or 0-10 V
adaptor Gas
meter
Water meters
schneider-electric.co.uk/metering 121
COMMUNICATIONS FUNCTIONS AND CHARACTERISTICS
Data collector
Collects and stores energy data from up to 64 field devices, connected to either:
• Ethernet TCP/IP field network.
• Modbus Serial line network (up to 32 devices).
• Embedded digital and analogue inputs.
122 schneider-electric.co.uk/metering
COMMUNICATIONS FUNCTIONS AND CHARACTERISTICS
Com’X 510
A highly flexible plug-and-play Energy Server Com’X 510 collects and stores WAGES consumptions
and environmental parameters such as temperatures, humidity and CO2 levels in a building. The Com’X
510 has up to 2 year data storage and embedded webpages which means all your energy data can be
viewed and managed on-site.
Applications
• All-in-one-box energy management solution especially suitable for buildings up to 10,000 sq. meters
schneider-electric.co.uk/metering 123
COMMUNICATIONS FUNCTIONS AND CHARACTERISTICS
Architecture
Ethernet or Wi-Fi LAN
Web browser Modbus Serial Line
Analogue / digital IOs
3. Save
Power
PowerView Ethernet or Monitoring
Remote Internet Wi-Fi LAN Expert
GPRS
Com’X 510
2. Connect
Ethernet |
Modbus TCP
Temperature
sensors
1. Measure
Modbus multi-meters
Circuit-breakers
Analogue Pulse energy meters
sensors
with 4-20 mA
or 0-10 V
adaptor Gas
meter
Water meters
124 schneider-electric.co.uk/metering
COMMUNICATIONS FUNCTIONS AND CHARACTERISTICS
Data collector
As soon as they are connected to the LAN, it can be detected and
assigned an IP address by DHCP. Your operating system’s DPWS feature
allows your computer to automatically recognise the device as Com’X.
Embedded web pages are then immediately accessible by clicking each
Com’X device icon or by typing the assigned IP address into your web
browser.
schneider-electric.co.uk/metering 125
COMMUNICATIONS FUNCTIONS AND CHARACTERISTICS
Additional functions
Data publisher
Batches of collected data can also be periodically transmitted to an
Internet server, as:
• XML files, for processing by StruxureWare™ web services, such as
Energy Operation
• CSV files for viewing in Excel or transformed or uploading to
programs such as StruxureWare™ Power Monitoring Expert or any
compatible software
Energy Server Com'X 510 data logger
Gateway
• If selected by the user, the Com’X 510 can make data from
connected devices available in real time
• In Modbus TCP/IP format over Ethernet or Wi-Fi
• For requests by energy management software
Raw data and measurements from one field device (partial
screen) Modbus packets can be sent from managing software to field devices
through Modbus serial line or Modbus TCP/IP over Ethernet.
126 schneider-electric.co.uk/metering
COMMUNICATIONS FUNCTIONS AND CHARACTERISTICS
ION7550 RTU
The PowerLogic ION7550 RTU (remote terminal unit) is an intelligent web-enabled device ideal for
combined utilities metering of water, air, gas, electricity and steam (WAGES). When combined with
Power management software, the ION7550 RTU offers a seamless, end-to-end WAGES metering
solution.
Featuring a large, high-visibility display and overall versatility of the PowerLogic system, the ION7550 RTU provides extensive
analogue and digital I/O choices and is a cost-effective dedicated WAGES solution when compared to a traditional meter.
The device automatically collects, scales and logs readings from a large number of connected meters or transducers and
delivers information to one or more head-end systems through a unique combination of integrated Ethernet, modem or serial
gateways.
Applications
• WAGES (water, air, gas, electricity, steam) metering
• Integrated utility metering with advanced programmable math functions
• Data concentration through multi-port, multi-protocol communications
• Equipment status monitoring and control
• Programmable set points for out-of-limit triggers or alarm conditions
schneider-electric.co.uk/metering 127
COMMUNICATIONS FUNCTIONS AND CHARACTERISTICS
All markets that can benefit from a solution that includes As part of a complete enterprise energy
PowerLogic ION7550RTU series meters: management solution, the ION7550 RTU
can be integrated with Power Monitoring
• Buildings
Expert, or other SCADA, information and
• Industry
automation systems. See Page 114
• Healthcare
• Education
Conformity of standards
• Etc.
• EN 61010-1 • IEC 61000-4-4
Competitive advantages
• Data concentration through multi-port, multi-protocol
communications
• Integrated utility metering with advanced programmable
function
Main characteristics
• Increase efficiency
–– Reduce waste and optimise equipment operation to increase efficiency.
• Easy to operate
–– Screen-based menu system to configure meter settings. Bright LCD display with adjustable contrast.
• Integrate with software
–– Easily integrated with PowerLogic or other energy management enterprises, including SCADA systems.
• Transducer and equipment condition monitoring
–– Versatile communications, extensive I/O points, clock synchronisation, event logging and sequence of events recording capabilities
for transducer and equipment condition and status monitoring at utility substations.
• Set automatic alarms
–– Alarm setpoint learning feature for optimum threshold settings.
• Up to 10 Mbytes of memory
–– For archiving of data and waveforms.
• Notify alarms via email
–– High-priority alarms sent directly to the user’s PC. Instant notification of power quality events by email.
• Modbus Master functionality
–– Aggregate and store data from downstream Modbus devices using serial or Ethernet connections
128 schneider-electric.co.uk/metering
COMMUNICATIONS FUNCTIONS AND CHARACTERISTICS
4
Part numbers
M 5 N9 Item Code Description
A None
9 Special Order
C Tropicalisation treatment applied
schneider-electric.co.uk/metering 129
COMMUNICATIONS FUNCTIONS AND CHARACTERISTICS
ION7550 RTU
Communication Card for ION7550RTU Ordering reference
Standard Comms: 1 RS232/RS485 port (COM1), 1 RS485 port (COM2), Front optical port (COM3) P765CA0A
Standard Comms: 1 RS232/RS485 port (COM1), 1 RS485 port (COM2), Front optical port (COM3), tropicalisation treatment
P765CA0C
applied
Standard plus Ethernet (10/100BASE-T), 56k universal internal modem (RJ11; shares COM3) P765CC1A
Standard plus Ethernet (10/100BASE-T), 56k universal internal modem (RJ11; shares COM3), tropicalisation treatment applied P765CC1C
Standard plus Ethernet (10/100BASE-T, 100BASE-FX), 56k internal modem (RJ11) P765CD7A
Standard plus Ethernet (10/100BASE-T, 100BASE-FX), 56k internal modem (RJ11), tropicalisation treatment applied P765CD7C
Standard plus 56k universal internal modem (RJ11; shares COM3) P765CM1A
Standard plus 56k universal internal modem (RJ11; shares COM3),tropicalisation treatment applied P765CM1C
four 0 to 20 mA analogue inputs, four 0 to 20 mA analogue outputs & 8 digital inputs P760ANA
four 0 to 20 mA analogue inputs, four 0 to 20 mA analogue outputs & 8 digital inputs,tropicalisation treatment applied P760ANC
four 0 to 1 analogue inputs, four -1 to 1 mA analogue outputs & 8 digital inputs. P760APA
four 0 to 1 analogue inputs, four -1 to 1 mA analogue outputs & 8 digital inputs,tropicalisation treatment applied P760APC
130 schneider-electric.co.uk/metering
COMMUNICATIONS FUNCTIONS AND CHARACTERISTICS
Ordering
OpenDAC rack, controllers, power supply
reference
OpenDAC rack. Holds up to 8 OpenLine modules to provide up to 16 I/O points. Requires communications controller 70LRCK16-48
OpenDAC OpenDAC RS-485 serial module. Communications controller for use in a Modbus RTU network. Supports up to 2
72-MOD-4000
70LRCK16-48 OpenDAC racks
OpenDAC Ethernet network module for use on an Modbus/TCP Ethernet network. Supports up to 2 OpenDAC racks
72-ETH-T000
85-264VAC/110-370VDC 15 Watt power supply. Required for applying power to the racks and controllers PS-240-15W
Ordering
OpenLine digital I/O modules
reference
digital input, 120VAC 70L-IAC
Ordering
OpenLine analogue I/O modules
reference
analogue input, current, 0-20mA 73L-II020
schneider-electric.co.uk/metering 131
Technical
Specifications
Communications
132 schneider-electric.co.uk/metering
COMMUNICATIONS FUNCTIONS AND CHARACTERISTICS
24 V DC (-20/+10%) or
Power supply
Power over Ethernet (PoE Class 3 IEEE 802.3 af) at 15 W
24 V DC, 130 mA at 20 °C
Consumption (typical)
PoE 48 V DC, 65 mA at 20 °C
electrostatic
EN 61000-6-2
discharge
radiated RF EN 61000-4-2
electrical fast
EN 61000-4-3
transients
surge EN 61000-4-4
conducted RF EN 61000-4-5
UL 60950
Safety - UL*
UL 61010-2-201
EMC IEC6100-6-2
Serial ports
Number of ports 2 (1 available at a time)
schneider-electric.co.uk/metering 133
COMMUNICATIONS FUNCTIONS AND CHARACTERISTICS
M RS232 port
N RS485 port
134 schneider-electric.co.uk/metering
COMMUNICATIONS FUNCTIONS AND CHARACTERISTICS
• 2 Ethernet ports
Connection points –– Used to either separate upstream connection from field devices network
1 Terminal block 3 Ethernet port #1
or to daisy chain Ethernet devices.
2 RJ45 cable 4 Ethernet port #2 –– RJ45 10/100 Base connectors.
–– Static IP address.
• Ethernet port #1
–– Connection to Local Area Network (LAN).
–– PoE Class 3 (802.3af) can act as main/backup power supply for the
Com'X.
–– DHCP client.
• GPRS modem
–– For connection to the data processing server through cellular or user's
APN network.
–– Also connect to Schneider Electric's Digital Service Platform.
–– Especially suitable for sites with no internet access.
–– Simply plugs into dedicated port under the front cover.
• GPRS antenna
–– Improves GPRS signal strength in case of poor transmission conditions.
–– Recommended for Com’X located inside metallic electrical panels.
schneider-electric.co.uk/metering 135
COMMUNICATIONS FUNCTIONS AND CHARACTERISTICS
• Schneider Electric devices display with the • Advanced diagnostics and troubleshooting
product image. features
• Other devices appear as “unknown,” • Modbus serial and TCP/IP device statistics.
allowing the user to manually assign a • Ethernet network statistics.
device type. • Communications check wizard.
• User can assign their own device types. • Direct reading of register values from local
• Users can complete additional device and remote devices.
identification fields, such as circuit ID or
building zone.
EBXA-GPRS
DANGER
EBX200
EBXA-GPRS-SIM ~ 0.6A
100-277V
45 85 106
24V 1.2A
90
50/60 Hz
63
144 2.48
5.66 69
2.71
DIN rail fitting (Front face IP40, terminals IP20).
136 schneider-electric.co.uk/metering
COMMUNICATIONS FUNCTIONS AND CHARACTERISTICS
Technical specifications
Com’X 200/510 Environment
GPRS dongle
-20º to +60°C (-4º to +140°F)
Operating temperature
GPRS dongle
-40º to +85°C (-40º to +185°F)
Storage temperature
Wif-Fi dongle
0º to +50°C (32º to +122°F)
Operating temperature
Wi-Fi dongle
-20º to +80°C (-4º to +176°F)
Storage temperature
USA UL 508
Europe EN 60950
Quality Brands
CE, UL
DC 24 V (+/- 10%) b b
Weight 450 g b b
schneider-electric.co.uk/metering 137
COMMUNICATIONS FUNCTIONS AND CHARACTERISTICS
ION7550 RTU
Features
ION7550 RTU
Data recording
Min/max of instantaneous values b
Data logs b
Event logs b
Trending b
SER (Sequence of event recording) b
Time stamping b
GPS synchronisation (1 ms) b
Memory (in Mbytes) 10
Display and I/O
Front panel display b
Pulse output 1
Digital or analogue inputs(max) 24
Digital or analogue outputs (max, including pulse output) 30
Communication
RS 485 port 1
RS 485 / RS 232 port 1
Optical port 1
Modbus TCP Master / Slave (Ethernet port) b/b
Modbus RTU Master / Slave (Serial port) b/b
Ethernet port (Modbus/TCP/IP protocol) 1
Ethernet gateway (EtherGate) 1
Alarms (optional automatic alarm setting b
Alarm notification via email (Meterm@il) b
HTML web page server (WebMeter) b
Internal modem 1
Modem gateway (ModemGate) b
DNP 3.0 through serial, modem, and I/R ports b
138 schneider-electric.co.uk/metering
COMMUNICATIONS FUNCTIONS AND CHARACTERISTICS
Electrical characteristics
Data update rate 1/2 cycle or 1 second
DC 110-300 V DC ±10%
DC low voltage
20-60 V DC ±10%
Power supply (optional)
Mechanical characteristics
Weight 1.9 kg
Environmental conditions
Storage
Display, TRAN -40 to +85ºC
temperature
Electromagnetic compatibility
Electrostatic discharge IEC 61000-4-2
Safety
Europe IEC 61010-1
(1) Consult the ION7550 / ION7650 installation guide for complete specifications.
(2) IEC 62051-22B with serial ports only.
schneider-electric.co.uk/metering 139
COMMUNICATIONS FUNCTIONS AND CHARACTERISTICS
ION7550 RTU
Communication
Infrared port(1) ANSI type 2, up to 19,200 bauds, ION, Modbus, DNP 3.0
Fibre-optic Ethernet link 100Base FX, SC duplex connector, 1300 nm, FO multimode with gradient index 62.5/125 µm or 50/125 µm, 2000 m link
EtherGate Communicates directly with up to 62 slave devices via available serial ports
Firmware characteristics
Down to 5ms interval burst recording, stores detailed characteristics of disturbances or outages. Trigger recording by a
High-speed data recording
user-defined setpoint, or from external equipment.
Channel assignments (800 channels via 50 data recorders) are configurable for any measurable parameter. Trigger
recorders based on
Load profiling
time interval, calendar schedule, alarm/event condition,
or manually.
Access historical data at the front panel. Display, trend and continuously update historical data with date and
Trend curves
timestamps for up to four parameters simultaneously.
Threshold alarms:
adjustable pickup and dropout setpoints and time delays, numerous activation levels possible for a given type of alarm
Alarms
user-defined priority levels
boolean combination of alarms is possible using the operators NAND, OR, NOR and XOR
Advanced security Up to 16 users with unique access rights. Perform resets, time syncs, or meter configurations based on user privileges
Display characteristics
Integrated display Back lit LCD, configurable screens
Languages English (1) All the communication ports may be used simultaneously.
140 schneider-electric.co.uk/metering
COMMUNICATIONS FUNCTIONS AND CHARACTERISTICS
L/+ N/-
Connect G terminal
to ground for AC
power source
Note: the current and voltage terminal strip (I52, I51, I42, I41, I32, I31, I22,
I21, I12, I11, V4, V3, V2, V1, Vref) is not present on the RTU.
schneider-electric.co.uk/metering 141
Monitoring
software
142 schneider-electric.co.uk/metering
A choice of powerful, effective solutions
StruxureWare™ power management software provides a complete power management supervisory
interface that gives you access from anywhere to your entire electrical network. The software converts
energy-related data into timely, accurate information for you to act on.
Track real-time power conditions, analyse power quality and reliability and respond quickly to alarms to avoid critical
situations. Our power management software provides extensive analysis and reporting tools, intuitive visualisation and control
interfaces, and flexible, scalable architectures that can meet your unique needs today and continue to do so well into the
future. The depth of different offerings makes it easy to match a product to your goals, your business and your budget.
schneider-electric.co.uk/metering 143
MONITORING SOFTWARE FUNCTIONS AND CHARACTERISTICS
Capacity planning
The solution for
Generator monitoring All the markets which can benefit from a solution that includes Power management software:
Asset
management • Buildings • Industry
Breaker aging management
• Data Centre • Infrastructure
UPS battery monitoring
• Healthcare • Utility
144 schneider-electric.co.uk/metering
MONITORING SOFTWARE FUNCTIONS AND CHARACTERISTICS
Typical applications
StruxureWare power management software has many
applications:
• Monitor the facility electrical network and verify reliable operation.
• Improve response to power-related events and restore operations
quickly.
• Analyse and isolate the source of power quality problems.
• Analyse energy use to identify waste and reduce cost.
• Estimate utility bills to verify accuracy and identify errors.
• Allocate energy costs to departments to drive accountability and
awareness.
• Reduce peak demand surcharges and power factor penalties.
• Idenfity excess capacity in existing infrastructure and avoid over-
building.
• Support proactive maintenance to prolong asset life.
• Network protection and control.
• Operate distribution network safely and reliably.
• Improve continuity of electrical service.
• Equipment monitoring and control.
• Energy availability and reliability.
• Verify the reliable operation of equipment.
• Support proactive maintenance to prolong asset life.
schneider-electric.co.uk/metering 145
MONITORING SOFTWARE FUNCTIONS AND CHARACTERISTICS
Web Clients
Access power monitoring system from anywhere on your network using
a web browser. Day-to-day functionality including system status, alarm
response, or viewing dashboards. Web client provides authenticated
access to common functions:
Engineering Workstations
Client software gives engineers and power users access to administrative
and configuration functions of the software, and real-time display, control,
and historical analysis functions.
Build and edit custom graphical displays to represent your facility. One-
line diagrams, campus maps, equipment plan views and mimic diagrams
are easily created using Vista graphical objects and imported graphic
files.
Use the designer interface to program ION devices and create system
applications with ION Technology and Virtual ION ProcessorsReporter
- generate or edit historical reporst for energy cost, consumption, and
power quality.
146 schneider-electric.co.uk/metering
MONITORING SOFTWARE FUNCTIONS AND CHARACTERISTICS
Functions
ECS Engineer workstation ECS Operator workstation
• Reporting.
Optical converter
EGX 400
PLC Islanding
PLC
EGX 400 • Power quality analysis. • Manual and automated control.
Remote I/O
rack
Data acquisition and integration
Compatible devices Compatible devices
Compatible devices Integrate WAGES (Water, Air, Gas, Electricity, Steam) metering. Native, out-of-
the-box support for dozens of devices (See Supported Devices section for
details).
• See numeric values, status indicators, gauges, and trends, all with intuitive
graphical navigation.
• Extend comprehensive out-of-the-box displays and create custom
graphical diagrams to represent your facility; one-line diagrams, campus
maps, equipment plan views and mimic diagrams can be created using
embedded graphical objects and imported graphic files.
• Quickly compare multiple devices in your network in real-time in a tabular
display.
• Choose from a library of pre-built tables, or create your own. Save your
favourites for quick access later.
Trend analysis
Equipment Status example
• Trend parameters to reveal demand peaks and track system-wide energy
costs.
• Graph any combination of measured parameters.
• Plot time-series or scatter charts.
• Perform calculations, obtain statistics, and display historical data.
• Identify dangerous trends and redistribute loads.
• Optimise network capacity and avoid over-building.
• View operating parameters and determine when maintenance is required.
• Avoid peak demand surcharges and power factor penalties.
schneider-electric.co.uk/metering 147
MONITORING SOFTWARE FUNCTIONS AND CHARACTERISTICS
Dashboards
Create engaging dashboard displays of your power monitoring system
information and easily share information with anyone in your facility.
• Make power monitoring information visible and engaging.
• Promote education and drive behaviour.
• Display as an interactive kiosk on corporate intranet or on wall-mounted display.
• Replace hard to maintain home-grown portals and dashboards.
• Chart or trend any quantity in your power monitoring database.
Load profile dashboard (sample) • Simply convert into other units (e.g. dollars, emissions, normalisations, etc.).
• Compare multiple time-ranges.
• Show impact of temperature, occupancy, or production values on energy usage.
• Create eye-catching backgrounds to enhance presentation value.
• User authentication for configuration, and both authenticated and unauthenticated modes
available for display.
148 schneider-electric.co.uk/metering
MONITORING SOFTWARE FUNCTIONS AND CHARACTERISTICS
Configuration tools
Our power management software is supplied with a package of configuration
tools designed to make set up uniquely easy and quick.
• Designed to help make project set up and network configuration fast and easy.
• Provides standard device types and their associated profiles and allows engineers to easily
customise the profiles of the devices specific to the project.
• Standardised tags per device profile (configurable), XML file.
• Standard interface for quick database generation:
StruxureWare provides many different report templates to
• Instantiation of devices, on a per object basis.
allow users to easily display and deliver the information they
need . • Creates tags, trends, alarms and events when devices are added to system.
• Batch editing supported by automation interface.
Interoperability
• Integrate all energy management and automation systems (SCADA, BAC, DCS, ERP, etc.)
• Share data with third-party SCADA, automation, and accounting systems.
• Comply with ODBC, OPC, and PQDIF standards.
Global solutions
Software is available in many languages - English, French, Spanish, German,
and Chinese. Software needs to be installed by Schneider Electric’s Power
Solution Application team or by a certified partner of Schneider Electric.
Contact your Schneider Electric representative.
schneider-electric.co.uk/metering 149
Other
PowerLogic
offers
150 schneider-electric.co.uk/metering
OTHER POWERLOGIC OFFERS FUNCTIONS AND CHARACTERISTICS
schneider-electric.co.uk/metering 151
OTHER POWERLOGIC OFFERS FUNCTIONS AND CHARACTERISTICS
Applications
• Energy management
• Network management
Competitive advantages
The solution for
• Standard offers, including meter
All retrofit markets that can benefit from a solution that includes
and integrated energy server, are
NEW retrofit metering kits:
designed for your metering solution
• Building
• Provide modified service and
• Industry solution
• Infrastructure
• Data centre and networks
152 schneider-electric.co.uk/metering
OTHER POWERLOGIC OFFERS FUNCTIONS AND CHARACTERISTICS
The range of retrofit metering kits includes The range of Schneider Electric retrofit
meters complying with BSEN62053 and metering kits are designed to measure the
includes MID approved meters as a energy consumed by a complete installation
standard offer. or part of it. (Ex: main incoming supply,
• Their configuration allows them to be installed where
warehouse or office floor).
there is limited space, they can be “stacked” to allow • Measurements include voltage, current, frequency,
for multiple meters and an integrated gateway server active and reactive power, power factor and harmonic
to be assembled together. distortion. Using this Information is the key to
• Split core Current Transformers 200:5A up to understanding energy use and can be used to target
2400:5A ratios are available preventing cable re- waste and identify energy saving opportunities.
routing or cable breaks for simple retrofit installation. • Standard retrofit metering kits incorporating MID
• Supplied pre wired with top entry gland plate, approved meters may be utilised for energy billing
connections are simple using a common connection purposes.
interface for current inputs, voltage reference,
pulsed output and Modbus communications
connections.
Retrofit metering kit (Including OFGEM approved PM Power meter standard BS EN 62053-22 Class 0.5S
RETMKOFGEM
meter) consult us
OFGEM Measurements Defined by application at time of order
200:5A split core current transformer H68102005A
200:5A up to 2400:5A split core current
Current transformers
300:5A split core current transformer H68103005A transformers BSEN 60044
400:5A split core current transformer H68114005A Voltage reference connections Fused 2A
600:5A split core current transformer H68116005A Retrofit kit enclosure dimensions 200mm H x 230mm W x 145 mm D
800:5A split core current transformer H68118005A Retrofit kit enclosure fixings 3 x 6 mm clearance dished hole fixings
1000:5A split core current transformer H681210005A Gland plate Top entry removable 230mm x 145 mm
schneider-electric.co.uk/metering 153
OTHER POWERLOGIC OFFERS FUNCTIONS AND CHARACTERISTICS
PowerLogic current
transformers
When current in a circuit is too high to apply directly to measuring instruments, a current
transformer produces a reduced current accurately proportional to the current in the circuit, which
can be conveniently connected to measuring and recording instruments.
This allows them to be used in combination with measurement equipment:
• Ammeters
• Kilowatt-hour meters
• Measurement units
• Control relays
• Etc.
Applications
The transformers from Schneider Electric are suitable for use in the field
from 40A up to 6000A and deliver at the secondary a current 0 to 5A
proportional to the current measured at the primary.
154 schneider-electric.co.uk/metering
OTHER POWERLOGIC OFFERS FUNCTIONS AND CHARACTERISTICS
The Ip/5A ratio current transformer delivers at the secondary a current (Is) of 0 to 5
DB416186.eps
When the primary is energised, the measurement equipment nearly acts as a short
circuit which keeps the secondary voltage very low. This voltage will increases
significantly if the short circuit is removed.
Conductor
Cable Mixed, bars or cables Vertical or horizontal bars Vertical bars
type
DB415988.eps
DB415920.eps
DB415989.eps
DB415986.eps
Suggested
Current
Transformer
DB415987.eps
and mounting
DB415921.eps
Ratings (A) 40 to 250 150 to 800 200 to 4000 500 to 600 5000 to 6000
CT internal
Type C Type M Type D (1) Type V
profile
MA MB MC
MD ME MF
VF VV
(1) Two secondary connectors (parallel internal wiring - only one secondary winding) for easier cable access. 1 lateral + 1 on one extremity. Warning: only one must be used at
a time. Specific mounting: use of cylinder
A cylindrical metallic spacer ensures a proper CT positioning when the conductor or the CT cannot be positioned perpendicular. Secured by bolt + nut.
16550 METSECT5CYL1
(brass) (aluminium)
schneider-electric.co.uk/metering 155
OTHER POWERLOGIC OFFERS FUNCTIONS AND CHARACTERISTICS
16 0.062
Application example
Project specification: 200 A, in Ø27 mm cable, accuracy class 1.
Our choice is METSECT5MA020.
For this CT selected on the chart (next page), the max acceptable power is 7 VA (for "Accuracy class 1" which is specified in the project).
Accuracy class
Rating
Internal profile Cables Bars
Ip/5 A Cat. no. 0.5 1 3
type (mm) (mm)
(A)
Max. power (VA)
MA
150 3 4 -
200 4 7 -
10 x 32
Ø27 250 6 8 -
15 x 25
300 8 10 -
400 10 12 -
156 schneider-electric.co.uk/metering
NOTES
schneider-electric.co.uk/metering 157
OTHER POWERLOGIC OFFERS FUNCTIONS AND CHARACTERISTICS
Examples:
• METSECT5CC008 = 5 A secondary, Cables only, 75 A primary
• METSECT5MC080 = 5 A secondary, Mixed for cables and bars, 800 A primary.
CC
40 METSECT5CC004
50 METSECT5CC005
60 METSECT5CC006
75 METSECT5CC008
Ø21 - 100 METSECT5CC010
125 METSECT5CC013
METSECT5CCppp 150 METSECT5CC015
200 METSECT5CC020
250 METSECT5CC025
PB112461.eps
PB112464.eps
150 METSECT5ME015
200 METSECT5ME020
10 x 30 250 METSECT5ME025
Ø22 11 x 25 300 METSECT5ME030
12 x 20 400 METSECT5ME040
500 METSECT5ME050
600 METSECT5ME060
METSECT5MEppp METSECT5MBppp
250 METSECT5MB025
PB112462.eps
12 x 40
Ø26 300 METSECT5MB030
PB112460.eps
15 x 32
400 METSECT5MB040
150 METSECT5MA015
200 METSECT5MA020
10 x 32
Ø27 250 METSECT5MA025
15 x 25
300 METSECT5MA030
400 METSECT5MA040
250 METSECT5MC025
METSECT5MAppp METSECT5MCppp 300 METSECT5MC030
10 x 40 400 METSECT5MC040
Ø32 20 x 32
PB112465.eps
25 x 25 500 METSECT5MC050
600 METSECT5MC060
PB112463.eps
800 METSECT5MC080
250 METSECT5MF025
300 METSECT5MF030
Ø35 10 x 40
400 METSECT5MF040
500 METSECT5MF050
500 METSECT5MD050
12 x 50
Ø40 600 METSECT5MD060
20 x 40
800 METSECT5MD080
158 schneider-electric.co.uk/metering
OTHER POWERLOGIC OFFERS FUNCTIONS AND CHARACTERISTICS
DB415927.eps
DB415926.eps
Common characteristics
Secondary current Is (A) 5
Maximum voltage rating Ue (V) 720
Frequency (Hz) 50/60
40 to 4000 A: sf y 5
Safety factor (sf)
5000 to 6000 A: sf y 10
Degree of protection IP20
DIN rail mounting. tropicalised range
Operating temperature -25 °C to +60 °C (1)
Mounting plate installation. relative humidity > 95 %
IEC 61869-2
Compliance with standards
VDE 0414
by terminals for lug
Secondary connection (as per model) by tunnel terminals
by screws
(1) Warning: some products are limited to +50 °C.
- - 1
- 1.25 1.5
- 1.25 2
- 1.5 2.5
Adapter for DIN rails. 16550
2 2.5 3.5 44 x 66 x 37 Included
Mounting plate. METSECT5CYL1
2.5 3.5 4
3 4 5
4 5.5 6
5 6 7
ME
1.5 5.5 6.5
4 7 8.5
6 9 11 Adapter for DIN rails.
7.5 11 14 56 x 84 x 60 Mounting plate. 16551 16552
10.5 15 18 Insulated locking screw.
12 18 22
14.5 21.5 26
MB
3 4 -
Adapter for DIN rails.
4 6 - 60 x 85 x 63 - METSECT5COVER
Mounting plate.
6 8 -
MA
3 4 -
4 7 -
Adapter for DIN rails.
6 8 - 56 x 80 x 63 METSECT5CYL2 METSECT5COVER
Mounting plate.
8 10 -
10 12 -
MC
3 5 -
5 8 -
8 10 - Adapter for DIN rails.
70 x 95 x 65
Mounting plate.
- METSECT5COVER
10 12 -
12 15 -
10 12 -
MF
2.5 5 8
4 8 12 Adapter for DIN rails.
77 x 107 x 64 Mounting plate. - 16553
8 12 15 Insulated locking screw.
10 12 15
MD
4 6 -
Adapter for DIN rails.
6 8 - 70 x 95 x 65 - METSECT5COVER
Mounting plate.
8 12 -
schneider-electric.co.uk/metering 159
OTHER POWERLOGIC OFFERS FUNCTIONS AND CHARACTERISTICS
PB112467.eps
Rating
Internal Cables Bars
Ip/5 A Cat. no.
profile type (mm) (mm)
(A)
500 METSECT5VF050
PB112466.eps
600 METSECT5VF060
11 x 64
-
31 x 51
5000 METSECT5VV500 g
6000 METSECT5VV600 g
METSECT5VFppp METSECT5VVppp - 55 x 165
200 METSECT5DA020
PB112454.eps
250 METSECT5DA025
300 METSECT5DA030
400 METSECT5DA040
500 METSECT5DA050
- 32 x 65
600 METSECT5DA060
METSECT5DAppp METSECT5DBppp
800 METSECT5DA080
1000 METSECT5DA100
PB112456.eps
1250 METSECT5DA125 g
PB112457.eps
1500 METSECT5DA150 g
1000 METSECT5DB100
1250 METSECT5DB125 g
1500 METSECT5DB150 g
- 38 x 127
2000 METSECT5DB200 g
2500 METSECT5DB250 g
METSECT5DCppp METSECT5DDppp 3000 METSECT5DB300 g
PB112459.eps
2000 METSECT5DC200 g
PB112458.eps
2500 METSECT5DC250 g
- 52 x 127
3000 METSECT5DC300 g
4000 METSECT5DC400 g
1000 METSECT5DD100
- 34 x 84 1250 METSECT5DD125 g
1500 METSECT5DD150 g
1000 METSECT5DE100
1250 METSECT5DE125 g
- 54 x 102
1500 METSECT5DE150 g
2000 METSECT5DE200 g
160 schneider-electric.co.uk/metering
OTHER POWERLOGIC OFFERS FUNCTIONS AND CHARACTERISTICS
VF
2 4 -
4 6 -
Mounting plate.
90 x 130 x 66
Insulated locking screw.
- Included
VV
60 - -
70 - -
175 x 273.5 x 110 Insulated locking screw. - Included
DA
- 2 5
1 4 -
1.5 6 -
4 8 -
8 10 -
90 x 94 x 90 Insulated locking screw. - Included
8 12 -
12 15 -
15 20 -
15 20 -
20 25 -
DB
6 10 -
8 12 -
10 15 -
99 x 160 x 87 Insulated locking screw. - Included
15 20 -
20 25 -
25 30 -
DC
25 30 -
30 50 -
125 x 160 x 87 Insulated locking screw. - Included
30 50 -
30 50 -
DD
10 15 -
15 20 -
DE
12 15 -
15 20 -
135 x 129 x 85 Insulated locking screw. - Included
20 25 -
20 25 -
schneider-electric.co.uk/metering 161
OTHER POWERLOGIC OFFERS FUNCTIONS AND CHARACTERISTICS
CT current transformers
CC internal profile type ME internal profile type MB internal profile type
162 schneider-electric.co.uk/metering
OTHER POWERLOGIC OFFERS FUNCTIONS AND CHARACTERISTICS
CT current transformers
DD internal profile type DE internal profile type
schneider-electric.co.uk/metering 163
OTHER POWERLOGIC OFFERS FUNCTIONS AND CHARACTERISTICS
Cylinders
METSECT5CYL1 METSECT5CYL2
Aluminium
Aluminium
16550 16551
Brass Brass
Covers
16552
16553
METSECT5COVER
164 schneider-electric.co.uk/metering
NOTES
schneider-electric.co.uk/metering 165
INDEX
A9MEM2010 IEM2010 Single phase kwh Meter 40A with pulsed output 15
A9MEM2105 IEM2105 Single phase Kwh Meter 63A with pulsed output 17
A9MEM2110 IEM2110 Single phase Kwh Meter 63A dual tariff, MID, 2 P/O & 1 DI 17
A9MEM2135 IEM2135 Single phase Kwh Meter 63A dual tariff, MID and M-bus 17
A9MEM2150 IEM2150 Single phase Kwh Meter 63A dual tariff and Modbus 17
A9MEM2155 IEM2155 Single phase Kwh Meter 63A dual tariff, MID and Modbus 17
B
BCPMCOVERS BCPM accessories BCPM Cover 104
BCPMA042S BCPM Branch Circuit Power Meter Version A 42CTs, 19mm 102
BCPMA084S BCPM Branch Circuit Power Meter Version A 84CTs, 19mm 102
BCPMA224S BCPM Branch Circuit Power Meter Version A 24CTs, 18mm 102
BCPMA236S BCPM Branch Circuit Power Meter Version A 36CTs, 18mm 102
BCPMA242S BCPM Branch Circuit Power Meter Version A 42CTs, 18mm 102
BCPMA248S BCPM Branch Circuit Power Meter Version A 48CTs, 18mm 102
BCPMA272S BCPM Branch Circuit Power Meter Version A 72CTs, 18mm 102
BCPMA284S BCPM Branch Circuit Power Meter Version A 84CTs, 18mm 102
BCPME042S BCPM Branch Circuit Power Meter Version E 42CTs, 19mm 102
BCPME084S BCPM Branch Circuit Power Meter Version E 84CTs, 19mm 102
BCPME224S BCPM Branch Circuit Power Meter Version E 24CTs, 18mm 102
166 schneider-electric.co.uk/metering
INDEX INDEX
BCPME242S BCPM Branch Circuit Power Meter Version E 42CTs, 18mm 102
BCPME248S BCPM Branch Circuit Power Meter Version E 48CTs, 18mm 102
BCPME272S BCPM Branch Circuit Power Meter Version E 72CTs, 18mm 102
BCPME284S BCPM Branch Circuit Power Meter Version E 84CTs, 18mm 102
BCPMSCA1S BCPM Branch Circuit Power Meter Version A 42CTs, split core CTs and cable sold seprately 103
BCPMSCA2S BCPM Branch Circuit Power Meter Version A 84CTs, split core CTs and cable sold seprately 103
BCPMSCA30S BCPM Branch Circuit Power Meter Version A 30CTs, split core 103
BCPMSCA42S BCPM Branch Circuit Power Meter Version A 42CTs, split core 103
BCPMSCA60S BCPM Branch Circuit Power Meter Version A 60CTs, split core 103
BCPMSCA84S BCPM Branch Circuit Power Meter Version A 84CTs, split core 103
BCPMSCAY63S BCPM Branch Circuit Power Meter Version A 42CTs, split core 103
BCPMSCADPBS BCPM accessories BCPM 2 adapter boards, for split core 104
BCPMSCE1S BCPM Branch Circuit Power Meter Version E 42CTs, split core CTs and cable sold seprately 103
BCPMSCE2S BCPM Branch Circuit Power Meter Version E 84CTs, split core CTs and cable sold seprately 103
BCPMSCE30S BCPM Branch Circuit Power Meter Version E 30CTs, split core 103
BCPMSCE42S BCPM Branch Circuit Power Meter Version E 42CTs, split core 103
BCPMSCE60S BCPM Branch Circuit Power Meter Version E 60CTs, split core 103
BCPMSCE84S BCPM Branch Circuit Power Meter Version E 84CTs, split core 103
BCPMSCCT0 BCPM accessories BCPM 50A split core CTs, Quantity 6, 1.8m lead length 104
BCPMSCCT0R20 BCPM accessories BCPM 50A Split Core CTs Quantity 6, 6m lead length 104
BCPMSCCT1 BCPM accessories BCPM 100A split core CTs, Quantity 6, 1.8m lead length 104
BCPMSCCT1R20 BCPM accessories BCPM 100A Split Core CTs Quantity 6, 6m lead length 104
BCPMSCCT3 BCPM accessories BCPM 200A split core CTs, Quantity 6, 1.8m lead length 104
BCPMSCCT3R20 BCPM accessories BCPM 200A Split Core CTs Quantity 6, 6m lead length 104
BATT-REPLACE-8XXX ION8800 accessories Replacement batteries for the ION 8600 or ION 8800, quantity 10 87
C
CBL016 BCPM accessories Flat Ribbon cable (quantity 1) for BCM o 104
CBL020 BCPM accessories Flat Ribbon cable (quantity 1) for BCM o 104
CBL021 BCPM accessories Flat Ribbon cable (quantity 1) for BCM o 104
CBL024 BCPM accessories Round Ribbon cable (quantity 1), length 104
E
EBX200 Com'X 200 Com'X 200 ETHERNET DATA LOGGER 122
I
ICE-OPTICAL-PROBE ION8800 accessories IEC 61107 compliant Optical Probe (DB-9) for use with ION 8800 meters 87
L
LVCT00202S BCPM accessories LOW VOLTAGE CT 200A 0 333VAC SPLIT CORE 104
schneider-electric.co.uk/metering 167
INDEX
ION7550,ION7650
M765xxxx ION7550,ION7650 accessories 72
accessories
ION7550,ION7650
M765RD ION7550/7650 remote display, Schneider Electric branded 73
accessories
ION7550,ION7650 ION7550/7650 remote display kit, includes display, 24 VDC power supply and Ethernet
M765RDPS 73
accessories cable, Schneider Electric branded
168 schneider-electric.co.uk/metering
INDEX
schneider-electric.co.uk/metering 169
INDEX
ION7550,ION7650
M1UB10A1V-10A 10A/1 VAC Universal Technic Clamp On Current Probe (Price per probe) 73
accessories
O
ION7550,ION7650
OPTICAL-PROBE Serial Optical Probe (DB-9) via IR port 73
accessories
ION7550,ION7650
OPTICAL-PROBE-USB USB Optical Probe via IR port 73
accessories
P
ION7550,ION7650,
P765xxx ION7550RTU ION7550,ION7650, ION7550RTU optional card 73, 130
accessories
ION7550,ION7650,
P760xx ION7550RTU ION7550,ION7650, ION7550RTU optional card 73, 130
accessories
ION7550,ION7650
P32UEP813-1000A 1000A/1 VAC Universal Technic Clamp On Current Probe (Price per probe) 73
accessories
ION7550,ION7650
P32UEP815-3000A 3000A/1 VAC Universal Technic Clamp On Current Probe (Price per probe) 73
accessories
ION7550,ION7650
P765GSKT Gasket for ION7x50 meters and RTU - IP 52 & UL NEMA 12 73
accessories
R
RETMKITEGX150 Retrofit metering kit Retrofit metering kit with EGX150 153
RETMKITEBX510 Retrofit metering kit Retro metering kit gateway server Com’X 510 153
RETMKITMIDE Retrofit metering kit Retro MET kit MID ETH 6DIDOREL 153
RETMKITMIDM Retrofit metering kit Retro MET kit MID Modbus P/O 153
IEC/DIN 34862 19” Rack with female mating voltage/current and I/O blocks
RACK8800RAW ION8800 accessories 87
unassembled
S
ION7550,ION7650
SCT1250-300-300A 300A/0.333 VAC Magnelabs Split Core Current Probe (Price per probe) 73
accessories
T
ION7550,ION7650
TERMCVR-7550 Terminal strip cover 57
accessories
170 schneider-electric.co.uk/metering
Get the support you need…
When you need it!
Our Customer Care app provides 24/7, immediate
access to technical and support information;
Schneider Electric
www.schneider-electric.co.uk www.schneider-electric.com/ie
December, 2015
SE9116
©2015 Schneider Electric. All Rights Reserved. This document has been
All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. printed on recycled paper