Technical Data Sheet: Description Values Technical Particulars

This document provides technical specifications for a 4.0mm2 single core copper cable with PVC insulation rated for 450/750 Volts. The cable has a rated current capacity of 32A at 30°C, is manufactured by FAST CABLES LTD to BS EN 60228, BS 6004 and IEC 60332-1 standards, and has key properties including a conductor operation temperature of 90°C and insulation thickness of 0.80mm. Electrical and mechanical test results are also specified including maximum DC resistance of 4.61 ohm/km and tensile strength of insulation between 15N/mm2 and a ±25% variation after aging.

Uploaded by

Ali Shahzad
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
633 views2 pages

Technical Data Sheet: Description Values Technical Particulars

This document provides technical specifications for a 4.0mm2 single core copper cable with PVC insulation rated for 450/750 Volts. The cable has a rated current capacity of 32A at 30°C, is manufactured by FAST CABLES LTD to BS EN 60228, BS 6004 and IEC 60332-1 standards, and has key properties including a conductor operation temperature of 90°C and insulation thickness of 0.80mm. Electrical and mechanical test results are also specified including maximum DC resistance of 4.61 ohm/km and tensile strength of insulation between 15N/mm2 and a ±25% variation after aging.

Uploaded by

Ali Shahzad
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

FAST CABLES LTD

www.fast-cables.com UAN:111-000-343

TECHNICAL DATA SHEET


Description Values

Technical Particulars
1 Manufacturer's Name FAST CABLES LTD.
2 Type of Cable 4.0mm² S/C CU/PVC/INS (90°C)
3 Rated Voltage 450/750 Volts
4 Nominal Size of Cable 4.0mm²
5 General Standard Followed BS EN 60228, BS 6004,
IEC 60332-1
6 Class of Conductor Class 2
7 Formation Circular Stranded
8 Current Carrying Capacity at 30°C Ambient Temperature 32 A
9 PVC Insulation material 90°C
10 Conductor Operation Temperature 90°C
11 Emergency Overload Temperature 120°C
12 Short Circuit Temperature 160°C
13 Thickness of Insulation 0.80mm
14 Overall Diameter of Cable (Approximate) 3.80- 4.60mm
15 Printing As Per Standard
16 Minimum Bending Radius 14mm
17 Voltage Drop (mV/A/m) 11
18 Flame Application Time 60 s
Electrical Tests
1 Conductor D.C Resistance at 20°C (Max) 4.61 ohm/km
2 Conductor A.C Resistance at 90°C (Max) 5.85 ohm/km
3 High voltage test 2.5 kV AC for 5 min
4 Insulation Resistance Constant at 90°C 0.0082 M ohm.km
Mechanical / Physical Tests
1 Tensile Strength of Insulation (Before Ageing) 15 N/mm²
2 Tensile Strength of Insulation (After Ageing) ±25% variation
3 Elongation of Insulation at Break (Before Ageing) 150%
4 Elongation of Insulation at Break (After Ageing) ±25% variation