General Specifications: EJX120A Differential Pressure Transmitter
General Specifications: EJX120A Differential Pressure Transmitter
General EJX120A
Specifications Differential Pressure Transmitter
GS 01C25B03-01EN
STANDARD SPECIFICATIONS
Refer to GS 01C25T02-01EN for Fieldbus
communication type and GS 01C25T04-01EN for
PROFIBUS PA communication type for the items Square Root Output Accuracy
marked with “◊.” The square root accuracy is a percent of flow span.
Output Accuracy
□ SPAN AND RANGE LIMITS 50% or Greater Same as reference accuracy
Reference accuracy × 50
Measurement inH2O mbar mmH2O 50% to Dropout point
kPa Square root output (%)
Span/Range (/D1) (/D3) (/D4)
0.025 to 1 0.1 to 4 0.25 to 10 2.5 to 100 Ambient Temperature Effects per 28°C (50°F)
Span
E (0.1 to 1) (0.4 to 4) (1 to 10) (10 to 100) Change
Range -1 to 1 -4 to 4 -10 to 10 -100 to 100 ±(0.1% Span + 0.15% URL)
( ) show the span limits for square root output. Stability (All normal operating condition, including
overpressure effects)
□ PERFORMANCE SPECIFICATIONS ±0.15% of URL per one year
Zero-based calibrated span, linear output, wetted Power Supply Effects(Output signal code D, E
parts material code S and silicone oil, unless and J)
otherwise mentioned. ±0.005 % per Volt (from 21.6 to 32 V DC, 350Ω)
For Fieldbus and PROFIBUS PA communication Vibration Effects
types, use calibrated range instead of span in the Amplifier housing code 1 and 3:
following specifications. Less than 0.1% of URL when tested per the
Specification Conformance requirements of IEC60770-1 field or pipeline
EJX series ensures specification conformance to at with high vibration level (10-60 Hz, 0.21 mm
least ±3σ. displacement/60-2000 Hz 3 g)
Reference Accuracy of Calibrated Span Amplifier housing code 2:
(includes terminal-based linearity, hysteresis, and Less than ±0.1% of URL when tested per the
repeatability) requirements of IEC60770-1 field with general
application or pipeline with low vibration level (10-60
Measurement span E Hz 0.15mm displacement /60-500 Hz 2g)
Reference X ≤ span ±0.09% of Span Mounting Position Effects
accuracy X > span ±(0.015+0.03 URL/span)% of Span Rotation in diaphragm plane has no effect. Tilting
X 0.4 kPa (1.6 inH2O) up to 90 degree will cause zero shift up to 0.4 kPa
URL (1.6 inH2O) which can be corrected by the zero
1 kPa (4 inH2O) adjustment.
(upper range limit)
Response Time (Differential pressure) “◊”
150 ms
When amplifier damping is set to zero and including
dead time of 45 ms (nominal)
All Rights Reserved. Copyright © 2007, Yokogawa Electric Corporation GS 01C25B03-01EN June 1, 2017-00
<<Contents>> <<Index>> 3
Supply & Load Requirements Safety Requirement Standards
(Output signal code D, E and J. Optional EN 61010-1, C22.2 No.61010-1
features or approval codes may affect electrical • Installation category: I
requirements.) (Anticipated transient overvoltage 330 V)
With 24 V DC supply, up to a 550Ω load can be • Pollution degree: 2
used. See graph below. • Indoor/Outdoor use
□ PHYSICAL SPECIFICATIONS
Wetted Parts Materials
600 Diaphragm, cover flange, process connector,
E-10.5 capsule gasket, and vent/drain plug
R=
External 0.0244 Digital Refer to “MODEL AND SUFFIX CODES.”
load Communication Process connector gasket
resistance range PTFE Teflon
BRAIN and HART
Fluorinated rubber for option code N2 and N3
250 Non-wetted Parts Materials
Bolting
R (Ω) B7 carbon steel, 316L SST or 660 SST
Housing
• Low copper cast aluminum alloy
10.5 16.6 25.2 42 • Low copper cast aluminum alloy with corrosion
Power supply voltage E (V DC) resistance properties (copper content ≤ 0.03%,
F01E.ai
iron content ≤ 0.15%) (optional)
Figure 1. Relationship Between Power Supply • ASTM CF-8M Stainless steel (optional)
Voltage and External Load Resistance
Coating of housing
[for aluminum housing]
Supply Voltage “◊” Polyester resin powder coating
10.5 to 42 V DC for general use and flameproof type. Mint-green paint (Munsell 5.6BG 3.3/2.9 or its
10.5 to 32 V DC for lightning protector equivalent)
(option code /A.) [for option code /P or /X2]
10.5 to 30 V DC for intrinsically safe, type n, or non- Epoxy and polyurethane resin solvent coating
incendive. Degrees of protection
Minimum voltage limited at 16.6 V DC for digital IP66/IP67, Type 4X
communications, BRAIN and HART
Cover O-rings
Load (Output signal code D, E and J) Buna-N, fluoro-rubber (optional)
0 to 1290Ω for operation
Name plate and tag
250 to 600Ω for digital communication
316 SST
Communication Requirements “◊”
Fill fluid
(Approval codes may affect electrical requirements.)
Silicone oil
BRAIN
Weight
Communication distance [Installation code 7, 8 and 9]
Up to 2 km (1.25 miles) when using CEV 3.7 kg (8.2 lb) without integral indicator, mounting
polyethylene-insulated PVC-sheathed cables. bracket, and process connector.
Communication distance varies depending on type of Add 1.5 kg (3.3lb) for Amplifier housing code 2.
cable used.
Connections
Load capacitance Refer to “MODEL AND SUFFIX CODES.”
0.22 µF or less Process connection of cover flange: IEC61518
Load inductance
3.3 mH or less < Related Instruments>
Input impedance of communicating device Power Distributor: Refer to GS 01B04T01-02E or
10 kΩ or more at 2.4 kHz. GS 01B04T02-02E
EMC Conformity Standards BRAIN TERMINAL: Refer to GS 01C00A11-00E
EN 61326-1 Class A, Table2
EN 61326-2-3
EN 61326-2-5 (for fieldbus)
European Pressure Equipment Directive
2014/68/EU
Sound Engineering Practice (for all capsules)
EU RoHS Directive
EN 50581
All Rights Reserved. Copyright © 2007, Yokogawa Electric Corporation GS 01C25B03-01EN Mar. 11, 2019-00
<<Contents>> <<Index>> 4
< Reference >
1. is a registered trademark of Yokogawa
Electric Corporation.
2. FieldMate; Trademark of Yokogawa Electric
Corporation.
3. Teflon; Trademark of E.I. DuPont de Nemours &
Co.
4. Hastelloy; Trademark of Haynes International Inc.
5. HART; Trademark of the HART Communication
Foundation.
6. FOUNDATION Fieldbus; Tradmark of Fieldbus
Foundation.
7. PROFIBUS; Registered trademark of Profibus
Nutzerorganisation e.v., Karlsruhe, Germany.
Other company names and product names used in
this material are registered trademarks or trademarks
of their respective owners.
All Rights Reserved. Copyright © 2007, Yokogawa Electric Corporation GS 01C25B03-01EN Mar. 11, 2019-00
<<Contents>> <<Index>> 5
MODEL AND SUFFIX CODES
Model Suffix Codes Description
EJX120A ............................... Differential pressure transmitter
Output signal -D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 to 20 mA DC with digital communication (BRAIN protocol)
-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 to 20 mA DC with digital communication (HART 5 protocol)
-J . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 to 20 mA DC with digital communication (HART 5 / HART 7 protocol)
(Refer to GS 01C25T01-01EN)
-F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital communication (FOUNDATION Fieldbus protocol, refer to
GS 01C25T02-01EN)
-G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital communication (PROFIBUS PA protocol, refer to GS 01C25T04-01EN)
Measurement E . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.025 to 1 kPa (0.1 to 4 inH2O)
span (capsule)
Wetted parts . . . . . . . . . . . . . . . . . . . . . . . . . Refer to “Wetted Parts Material” Table below.
material *1
Process connections 0 . . . . . . . . . . . . . . . . . . . . . . without process connector (Rc1/4 female on the cover flanges)
1 . . . . . . . . . . . . . . . . . . . . . . with Rc1/4 female process connector
2 . . . . . . . . . . . . . . . . . . . . . . with Rc1/2 female process connector
3 . . . . . . . . . . . . . . . . . . . . . . with 1/4 NPT female process connector
4 . . . . . . . . . . . . . . . . . . . . . . with 1/2 NPT female process connector
► 5 . . . . . . . . . . . . . . . . . . . . . . without process connector (1/4 NPT female on the cover flanges)
Bolts and nuts materia J . . . . . . . . . . . . . . . . . . . B7 carbon steel
G . . . . . . . . . . . . . . . . . . . 316L SST
C . . . . . . . . . . . . . . . . . . . 660 SST
Installation -7 . . . . . . . . . . . . . . . . . Vertical piping, left side high pressure, and process connection downside
-8 . . . . . . . . . . . . . . . . . Horizontal piping and right side high pressure
► -9 . . . . . . . . . . . . . . . . . Horizontal piping and left side high pressure
-U . . . . . . . . . . . . . . . . . Universal flange
Amplifier housing 1 . . . . . . . . . . . . . . Cast aluminum alloy
3 . . . . . . . . . . . . . . Cast aluminum alloy with corrosion resistance properties*2
2 . . . . . . . . . . . . . . ASTM CF-8M stainless steel*3
Electrical connection 0 . . . . . . . . . . . G1/2 female, one electrical connection without blind plugs
► 2 . . . . . . . . . . . 1/2 NPT female, two electrical connections without blind plugs
4 . . . . . . . . . . . M20 female, two electrical connections without blind plugs
5 . . . . . . . . . . . G1/2 female, two electrical connections and a blind plug*4
7 . . . . . . . . . . . 1/2 NPT female, two electrical connections and a blind plug*4
9 . . . . . . . . . . . M20 female, two electrical connections and a blind plug*4
A . . . . . . . . . . . G1/2 female, two electrical connections and a SUS316 blind plug
C . . . . . . . . . . . 1/2 NPT female, two electrical connections and a SUS316 blind plug
D . . . . . . . . . . . M20 female, two electrical connections and a SUS316 blind plug
Integral indicator D . . . . . . . . Digital indicator*5
E . . . . . . . . Digital indicator with the range setting switch (push button)*6
► N . . . . . . . . None
Mounting bracket ► B . . . . . . 304 SST 2-inch pipe mounting, flat type (for horizontal piping)
D . . . . . . 304 SST or SCS13A 2-inch pipe mounting, L type (for vertical piping)
J . . . . . . 316 SST 2-inch pipe mounting, flat type (for horizontal piping)
K . . . . . . 316 SST or SCS14A 2-inch pipe mounting, L type (for vertical piping)
N . . . . . . None
Optional Codes / Optional specification
The “►” marks indicate the most typical selection for each specification.
*1: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of
inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage
to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm
and the fill fluid can contaminate the user’s process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium
hypochlorite, and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the
wetted parts material.
*2: Not applicable for electrical connection code 0, 5, 7, 9 and A.
*3: Not applicable for electrical connection code 0, 5, 7 and 9.
*4: Material of a blind plug; aluminum alloy for code 5 and 9, and SUS304 for code 7.
*5: Not applicable for output signal code G.
*6: Not applicable for output signal code F.
All Rights Reserved. Copyright © 2007, Yokogawa Electric Corporation GS 01C25B03-01EN June 1, 2017-00
<<Contents>> <<Index>> 6
Table. Wetted Parts Materials
Wetted parts Cover flange and process
Capsule Capsule gasket Vent/Drain plug
material code connector
Hastelloy C-276 (Diaphragm)
*2
S# ASTM CF-8M *1 PTFE Teflon 316 SST
F316L SST, 316L SST (Others)
*1: Cast version of 316 SST. Equivalent to SCS14A.
*2: Hastelloy C-276 or ASTM N10276.
The ‘#’marks indicate the construction materials conform to NACE material recommendations per MR0175/ISO15156.
Please refer to the latest standards for details. Selected materials also conform to NACE MR0103.
All Rights Reserved. Copyright © 2007, Yokogawa Electric Corporation GS 01C25B03-01EN June 1, 2017-00
<<Contents>> <<Index>> 7
Item Description Code
Canadian CSA Explosionproof Approval *1
Standards Certificate: 2014354
Association Applicable Standard: C22.2 No.0, C22.2 No.0.4, C22.2 No.0.5, C22.2 No.25, C22.2 No.30,
(CSA) C22.2 No.94, C22.2 No.60079-0, C22.2 No.60079-1, C22.2 No.61010-1, C22.2 No.61010-2-030
Explosion-proof for Class I, Groups B, C and D.
Dustignition-proof for Class II/III, Groups E, F and G.
When installed in Division 2, “SEAL NOT REQUIRED” Enclosure: Type 4X,
Temp. Code: T6...T4
CF1
Ex d IIC T6...T4 Enclosure: IP66/IP67
Max.Process Temp.: T4;120°C(248°F), T5;100°C(212°F), T6; 85°C(185°F)
Amb.Temp.: –50 to 75°C(–58 to 167°F) for T4, –50 to 80°C(–58 to 176°F) for T5,
–50 to 75°C(–58 to 167°F) for T6 *3
Process Sealing Certification
Dual Seal Certified by CSA to the requirement of ANSI/ISA 12.27.01
No additional sealing required
Primary seal failure annunciation: at the zero adjustment screw
CSA Intrinsically safe Approval *1*2
Certificate: 1606623
[For CSA C22.2]
Applicable Standard: C22.2 No.0, C22.2 No.0.4, C22.2 No.25, C22.2 No.94, C22.2 No.157,
C22.2 No.213, C22.2 No.61010-1, C22.2 No.60079-0, C22.2 No.61010-2-030
Intrinsically Safe for Class I, Division 1, Groups A, B, C & D, Class II, Division 1, Groups E, F & G,
Class III, Division 1, Nonincendive for Class I, Division 2, Groups A, B, C & D, Class II, Division 2,
Groups F & G, Class III, Division 1
Enclosure: Type 4X, Temp. Code: T4 Amb. Temp.: –50 to 60°C(–58 to 140°F) *3
Electrical Parameters: [Intrinsically Safe] Vmax=30V, Imax=200mA, Pmax=0.9W, Ci=10nF, Li=0 µH
[Nonincendive] Vmax=30V, Ci=10nF, Li=0 µH CS1
[For CSA E60079]
Applicable Standard: CAN/CSA E60079-11, CAN/CSA E60079-15, IEC 60529:2001
Ex ia IIC T4, Ex nL IIC T4 Enclosure: IP66/IP67
Amb. Temp.: –50 to 60°C(–58 to 140°F) *3, Max. Process Temp.: 120°C(248°F)
Electrical Parameters: [Ex ia] Ui=30V, Ii=200mA, Pi=0.9W, Ci=10nF, Li=0 µH
[Ex nL] Ui=30V, Ci=10nF, Li=0 µH
Process Sealing Certification
Dual Seal Certified by CSA to the requirement of ANSI/ISA 12.27.01
No additional sealing required
Primary seal failure annunciation: at the zero adjustment screw
Combined CF1 and CS1 *1*2 CU1
IECEx IECEx Flameproof Approval *1
Scheme Applicable Standard: IEC 60079-0:2011, IEC60079-1:2007-4
Certificate: IECEx CSA 07.0008
Flameproof for Zone 1, Ex d IIC T6...T4 Gb Enclosure: IP66/IP67 SF2
Max.Process Temp.: T4;120°C(248°F), T5;100°C(212°F), T6; 85°C(185°F)
Amb.Temp.: –50 to 75°C(–58 to 167°F) for T4, –50 to 80°C(–58 to 176°F) for T5,
–50 to 75°C(–58 to 167°F) for T6
IECEx Intrinsically safe and Flameproof Approval *1*2
Intrinsically safe Ex ia
Certificate: IECEx DEK 11.0081X
Applicable Standard: IEC 60079-0:2011, IEC 60079-11:2011
Ex ia IIC T4 Ga Enclosure: IP66/IP67
Amb. Temp.: –50 to 60°C(–58 to 140°F), Max. Process Temp.: 120°C(248°F)
Electrical Parameters: Ui=30V, Ii=200mA, Pi=0.9W, Ci=27.6nF, Li=0 μH
Intrinsically safe Ex ic
Certificate: IECEx DEK 13.0061X
Applicable Standard: IEC 60079-0:2011, IEC 60079-11:2011
SU21
Ex ic IIC T4 Gc IP code: IP66
Amb. Temp.: –30 to 60°C(–22 to 140°F) *3, Max. Process Temp.: 120°C(248°F)
Electrical Parameters: Ui=30V,Ci=27.6 nF, Li=0 μH
Flameproof
Certificate: IECEx CSA 07.0008
Applicable Standard: IEC 60079-0:2011, IEC60079-1:2007-4
Flameproof for Zone 1, Ex d IIC T6...T4 Gb Enclosure: IP66/IP67
Max.Process Temp.: T4;120°C(248°F), T5;100°C(212°F), T6; 85°C(185°F)
Amb.Temp.: –50 to 75°C(–58 to 167°F) for T4, –50 to 80°C(–58 to 176°F) for T5,
–50 to 75°C(–58 to 167°F) for T6
Combination of Combination of KU22, FU1 and CU1 *1*2*4
V1U1
Approval
*1: Applicable for Electrical connection code 2, 4, 7, 9, C and D.
*2: Not applicable for option code /AL.
*3: Lower limit of ambient temperature is –15°C (5°F) when /HE is specified.
*4: When this option code is specified, a wired tag plate (as of N4 option) shall be used for tag number.
All Rights Reserved. Copyright © 2007, Yokogawa Electric Corporation GS 01C25B03-01EN June 1, 2017-00
<<Contents>> <<Index>> 8
OPTIONAL SPECIFICATIONS
Item Description Code
Painting Color change Amplifier cover only*9 P
Amplifier cover and terminal cover, Munsell 7.5 R4/14 PR
Coating change Anti-corrosion coating*1 X2
316 SST exterior parts 316 SST zero-adjustment screw and setscrews*10 HC
Fluoro-rubber O-ring All O-rings of amplifier housing. Lower limit of ambient temperature: –15°C (5°F) HE
Lightning protector Transmitter power supply voltage: 10.5 to 32 V DC (10.5 to 30 V DC for intrinsically safe type.)
Allowable current: Max. 6000 A (1×40 µs), Repeating 1000 A (1×40 µs) 100 times A
Applicable Standards: IEC 61000-4-4, IEC 61000-4-5
Status output*2 Transistor output (sink type)
AL
Contact rating: 30 V DC, 120 mA DC(max ) Low level: 0 to 2 V DC
Oil-prohibited use*3 Degrease cleansing treatment K1
Oil-prohibited use with
Degrease cleansing and dehydrating treatment K5
dehydrating treatment*3
Calibration units*4 P calibration (psi unit) D1
bar calibration (bar unit) (See Table for Span and Range Limits.) D3
M calibration (kgf/cm2 unit) D4
Long vent*5 Total length: 119 mm (standard: 34 mm); Total length when combining with option code K1,
U1
K2, K5, and K6: 130 mm. Material: 316 SST
Output limits and failure Failure alarm down-scale: Output status at CPU failure and hardware error is −5%, 3.2mA DC
C1
operation*6 or less.
Failure alarm down-scale: Output status at CPU
NAMUR NE43 Compliant C2
failure and hardware error is −5%, 3.2 mA DC or less.
Output signal limits:
3.8 mA to 20.5 mA Failure alarm up-scale: Output status at CPU
C3
failure and hardware error is 110%, 21.6 mA or more.
Body option*7 Right side high pressure, without drain and vent plugs N1
Terminal N1 and Process connection, based on IEC61518 with female thread on both sides of cover
Side N2
flange, with blind kidney flanges on back.
L H N2, and Material certificate for cover flange, diaphragm, capsule body, and blind kidney flange N3
F02E.ai
Wired tag plate 316 SST tag plate wired onto transmitter (Tag No.: Maximum. 16 characters.) N4
Data configuration at factory*8 Software damping, Descriptor,
Data configuration for HART communication type CA
Message
Data configuration for BRAIN communication type Software damping CB
Advanced diagnostics*11 Multi-sensing process monitoring
• Impulse line blockage detection *12 DG6
• Heat trace monitoring
Material certificate*13 Cover flange *14 M01
Cover flange, Process connector *15 M11
Pressure test/ Nitrogen(N2) Gas*17
Test Pressure: 50 kPa (7.25 psi) T04
Leak test certificate*16 Retention time: one minute
*1: Not applicable with color change option. Not applicable for amplifier housing code 2.
*2: Check terminals cannot be used when this option code is specified. Not applicable for output signal code F and G and
amplifier housing code 2.
*3: Applicable for Wetted parts material code S.
*4: The unit of MWP (Max. working pressure) on the name plate of a housing is the same unit as specified by option codes D1,
D3, and D4.
*5: Applicable for vertical impulse piping type (Installation code 7) and Wetted parts material code S.
*6: Applicable for output signal codes D, E and J. The hardware error indicates faulty amplifier or capsule.
*7: Applicable for wetted parts material code S; process connection codes 3, 4, and 5; installation code 9; and mounting
bracket code N. Process connection faces on the other side of zero adjustment screw.
*8: Also see ‘Ordering Information’.
*9: Not applicable for amplifier housing code 2 and 3.
*10: 316 or 316L SST. The specification is included in amplifier housing code 2.
*11: Applicable only for output signal code E and J.
*12: The change of pressure fluctuation is monitored and then detects the impulse line blockage. See TI 01C25A31-01E for
detailed technical information required for using this function. The detection is for one side only.
*13: Material traceability certification, per EN 10204 3.1B.
*14: Applicable for process connections codes 0 and 5.
*15: Applicable for process connections codes 1, 2, 3, and 4.
*16: The unit on the certificate is always Pa unit regardless of selection of option code D1, D3 or D4.
*17: Pure nitrogen gas is used for oil-prohibited use (option codes K1 and K5).
All Rights Reserved. Copyright © 2007, Yokogawa Electric Corporation GS 01C25B03-01EN Mar. 11, 2019-00
<<Contents>> <<Index>> 9
DIMENSIONS
Unit: mm (approx.inch)
Electrical connection
for code 5, 9, A, and D.
54 (0.24)
6
256(10.10) 110(4.33)
194(7.64)
(2.13)
97 143(5.63) 12 39
(1.54) 2-inch pipe
(3.82) (0.47)
(O.D. 60.5 mm)
(L-type,optional)
52
(optional)
Integral indicator
(optional)
102(4.02)
234(9.21)
ø78(3.07)
148(5.83)*2
(3.74)
(2.76)
95*4
ø70
(1.81)
72(2.83)
46
Process
Conduit connector
connection (optional)
Process connection 54
41.3 Zero adjustment High Low
pressure (2.13) pressure
(1.63) Ground terminal side*1 side*1 F03E.ai
54
(2.13) (2.76)
ø70
6
159(6.26)
(0.24) 143(5.63)
194(7.64)
(1.63)
41.3
Ground terminal
133*3
(5.24) F04E.ai
*1: When installation code 8 is selected, high and low pressure side on above figure are reversed.
(i.e. High pressure side is on the right side.)
*2: When option code K1, K2, K5 or K6 is selected, add 15 mm (0.59 inch) to the value in the figure.
*3: When option code K1, K2, K5 or K6 is selected, add 30 mm (1.18 inch) to the value in the figure.
*4: When electrical connection code 7 or C is selected, a blind plug is protruded upto 8 mm from the conduit connection.
All Rights Reserved. Copyright © 2007, Yokogawa Electric Corporation GS 01C25B03-01EN Mar. 11, 2019-00
<<Contents>> <<Index>> 10
Unit: mm (approx.inch)
● Universal Flange (INSTALLATION CODE ‘U’)
ø78(3.07)
(2.13)
6
(2.76)
ø70
(0.24) 159(6.26)
143(5.63)
194(7.64)
Ground terminal
Electrical connection
for code 5, 9, A, and D.
(1.63)
41.3
Vent plug
Drain plug
46 Drain plug
54
Vent plug (1.81) High (2.13) Low
Process connection pressure pressure
125(4.92) side 133(5.24)*1 side
Drain plug Process connector (optional) F05E.ai
*1: When Option code K1, K2, K5, or K6 is selected, add 30 mm (1.18 inch) to the value.
*2: When electrical connection code 7 or C is selected, a blind plug is protruded upto 8 mm from the conduit connection.
Connection Description
Analog output EJX electrical terminal
Distributor
+ + 24V DC
SUPPLY
– 250Ω
*1
CHECK A *1: Either A or + –
– – 250Ω
If shield cable is not
*1
used, communication ALARM A
is not possible. *1: Either A or +
Magnetic
External power supply valve
30V DC, 120mA max
All Rights Reserved. Copyright © 2007, Yokogawa Electric Corporation GS 01C25B03-01EN Mar. 11, 2019-00
<<Contents>> <<Index>> 11
< Ordering Information > “◊” < Factory Setting > “◊”
Specify the following when ordering
Tag number As specified in order
For output signal code –J, refer to GS 01C25T01-
01EN. Software
‘2.00 s’ or as specified in order
damping *1
1. Model, suffix codes, and option codes
Output mode ‘Linear’ unless otherwise specified in order
2. Calibration range and units
1) Calibration range can be specified with range Calibration range
As specified in order
lower range value
value specifications up to 5 digits (excluding
any decimal point) for low or high range limits Calibration range
upper range As specified in order
within the range of -32000 to 32000. When
value
reverse range is designated, specify Lower
Range Value(LRV) as greater than Upper Range Selected from mmH2O, mmH2O(68°F),
mmAq*2, mmWG*2, mmHg, Pa, hPa*2,
Value(URV). When square root output mode is Calibration range kPa, MPa, mbar, bar, gf/cm2,
specified, LRV must be “0 (zero) ”. unit kgf/cm2, inH2O, inH2O(68°F), inHg, ftH2O,
2) Specify only one unit from the table, ‘Factory ftH2O(68°F) or psi. (Only one unit can be
setting.’ specified.)
3. Select linear or square root for output mode and Designated differential pressure value
display mode. specified in order. (% or user scaled
Note: If not specified, the instrument is shipped set for Display setting
value.) Display mode ‘Linear’ or ‘Square
linear mode. root’ is also as specified in order.
4. Display scale and units (for transmitters equipped
with the integral indicator only) *1: To specify these items at factory, option code CA
Specify either 0 to 100 % or ‘Range and Unit’ for or CB is required.
engineering units scale: *2: Not available for HART protocol type.
Scale range can be specified with range limit
specifications up to 5 digits (excluding any decimal < Material Cross Reference >
point) for low or high range limits within the range
of -32000 to 32000. Unit display consists of 6-digit, ASTM JIS
therefore, if the specified scaling unit excluding ‘/’ is 316 SUS316
longer than 6-characters , the first 6 characters will F316 SUSF316
be displayed on the unit display. 316L SUS316L
5. Tag Number (if required) F316L SUSF316L
Specified characters (up to 16 characters for 304 SUS304
BRAIN, 22 characters for HART, or 16 characters
F304 SUSF304
for /N4 tag) are engraved on the stainless steel tag
plate fixed on the housing. 660 SUH660
6. SOFTWARE TAG (for HART only. if required) B7 SNB7
Specified characters (up to 32 characters) are set CF-8M SCS14A
as “Tag” (the first 8 characters) and “Long tag”*1
(32 characters) in the amplifier memory. Use
alphanumeric capital letters. < Information on EU WEEE Directive >
When the “SOFTWARE TAG” is not specified, EU WEEE (Waste Electrical and Electronic Equipment)
specified “TAG NO” is set as “Tag” (the first 8 Directive is only valid in the EU.
characters) and “Long tag”*1 (22 characters) in the This instrument is intended to be sold and used only
amplifier memory. as a part of equipment which is excluded from WEEE
*1: applicable only when HART 7 is selected. Directive, such as large-scale stationary industrial
7. Other factory configurations (if required) tools, a large-scale fixed installation and so on, and,
Specifying option code CA or CB will allow further therefore, subjected to the exclusion from the scope
configuration at factory. Following are configurable of the WEEE Directive. The instrument should be
items and setting range. disposed of in accordance with local and national
[/CA : For HART communication type] legislation/regulations.
1) Descriptor (up to 16 characters)
2) Message (up to 30 characters)
3) Software damping in second (0.00 to 100.00)
[/CB : For BRAIN communication type]
1) Software damping in second (0.00 to 100.00)
All Rights Reserved. Copyright © 2007, Yokogawa Electric Corporation GS 01C25B03-01EN Mar. 11, 2019-00
Subject to change without notice.