0% found this document useful (0 votes)
253 views

Operating Instructions For OWS

The document provides operating instructions for an oily water separator. It lists 6 steps: [1] Check the alarm system and valves are open; [2] Fill the separator with seawater and test the alarm; [3] Shut valves C and D and start the bilge pump to pressurize the separator; [4] Intermittently check for oil; [5] Flush the system with seawater and close inlet and overboard valves; [6] Notes prohibit oil discharge overboard and requires chief engineer permission to operate.

Uploaded by

Srini Vasan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
253 views

Operating Instructions For OWS

The document provides operating instructions for an oily water separator. It lists 6 steps: [1] Check the alarm system and valves are open; [2] Fill the separator with seawater and test the alarm; [3] Shut valves C and D and start the bilge pump to pressurize the separator; [4] Intermittently check for oil; [5] Flush the system with seawater and close inlet and overboard valves; [6] Notes prohibit oil discharge overboard and requires chief engineer permission to operate.

Uploaded by

Srini Vasan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 1

CONTROL NO : ER 13/A

REV : 0 DTD : JAN,08

OPERATING INSTRUCTIONS FOR OILY WATER


SEPARATOR
 CHECK POWER FOR ALARM SYSTEM ON,

 CHECK INLET TO SEPARATOR & OVER BOARD V/V S OPEN,

 CHECK BALL V/V S A & B ARE OPEN,

 FILL SEPARATOR COMPLETELY WITH SEAWATER BY OPENING V/V S


C & D AND CHECK THE FUNCTION OF THE SEPARATOR ALARM AND
CHANGE OVER V/V BY PRESSING THE TEST SWITCH IN THE ALARM
PANEL,

 SHUT THE V/VS C & D, START BILGE SEPARATOR SERVICE P/P AND
GIVE FEED MAINTAIN A PRESSURE OF 1.2 ~ 3.0 BAR IN THE
SEPARATOR, THIS ADJUSTMENT CAN BE DONE BY THE OUTLET
PRESSURE ADJUSTING V/V,

 INTERMITTENTLY CHECK FOR OIL BY OPENING THE TEST COCK E,

 AFTER USE, FLUSH THE SEPARATOR SYSTEM WITH SEAWATER AND


SHUT INLET V/V TO SEPARATOR & THE OVERBOARD V/V.

NOTE:

 DISCHARGE OF OIL OVERBOARD IS PROHIBITED.

 DO NOT OPERATE WITHOUT PERMISSION FROM CHIEF


ENGINEER.

CHIEF ENGINEER
M.T._____________