NivoSWITH - R-300 (Manual)
NivoSWITH - R-300 (Manual)
1. APPLICATION
We are sure that you will be satisfied throughout its use.
NIVOSWITCH
NIVOSWITCH R-300 series vibrating forks are for level detection of powder, lumpy solids and granules.
Overfilling and emptying of silos or vessels can be prevented when using them as high or low fail safe
switches. The RC series (basic type insertion length = 125 mm) with casted forks are recommended for small
granules, while the RL series (basic type insertion length = 137 mm) with welded forks are recommended for
larger granules. Both RC and RL series are also available in dust Ex versions.
2. TECHNICAL DATA
2.1 GENERAL DATA
TYPE R – 3 – , R – 3 – Ex
Medium pressure 40 bar, 6 bar with PP flange See Derating diagram
Insertion length 0.125 … 3 m
Material of wetted parts Casted fork DIN 1.4404, welded fork DIN 1.4571
Medium temperature -40 °C … +130 °C, See Derating diagram
Ambient temperature -40 °C … +70 °C, See Derating diagram
Medium 0.01 kg/dm3
Getting immersed 0.5 sec
Switching delay 1 s – selected high density (H) ( 0.5 kg/dm3)
Getting free
3 s – selected low density (L) ( < 0.5 kg/dm3)
Indication of operation Bi-colour LED
Test of operation Output state can be changed with test magnet
2.4 ACCESSORIES
– User’s Manual – Declaration of Conformity – Gasket 2 mm klingerit (KLINGER OILIT) ring (1 pc)
– Warranty Card – RPS-101 type screw driver with test magnet (optional) – Sliding sleeve: RPH-112 (optional)
TYPE CODE CONNECTION CODE CONNECTION CODE INSERTION LENGTH CODE OUTPUT CODE
Casted fork C 1” BSP M 2” ANSI RF 600 1.4571 B 125 / 137 mm 01 2-wire AC+ connector 1
Welded fork L 1½” BSP H JIS 10K 50 A PP J 200 / 175 mm 02 2-wire AC + cable 2
1” NPT P JIS 40K 50 A 1.4571 K 0.3 … 3 m 03…30 3-wire DC + connector 3
1½” NPT N 1½” Triclamp T 3-wire DC + cable 4
DN50 PN 16 PP DIN F 2” Triclamp R 2-wire DC+ connector 6
DN50 PN 40 1.4571 DIN G Pipe coupling DN 40 D 2-wire DC + cable 7
2” ANSI RF150 PP A Pipe coupling DN 50 E Dust Ex
2-wire AC+ connector C
* The order code of an Ex version should end is ‘Ex’ 2-wire AC + cable D
3-wire DC+ connector E
3-wire DC + cable F
Tank pressure (pT) versus the ambient temperature (TM) Temperature limits for DC Tank pressure (pT) versus ambient temperature (TM) Temperature limits AC [TA]
devices [IL] Current load for PP flange ambient temperature [TM]
[TA] ambient temperature medium temperature
2.7 DIMENSIONS
RLH–303..30– RLH–301–, RLH–302– Triclamp (ISO 2852) Pipe coupling DIN11581
113
40
~108
~117
Ø 40 Ø 40
BSP1 1/2"
113
SW=46 or
NPT 1 1/2" 40
A
BSP1 1/2" Ø 28
or
300-3000
SW=46
1½", 2" Triclamp
NPT1 1/2"
~125
(ISO 2852)
~130
137/175
PVC
~110
EPDM
KO35 (1.4571) Polyamid,
Ø 40 s = 41
~113
glassfibre reinforced
15
Ø 40
s = 55 KO35 (1.4571)
KO35 (1.4571)
s = 41
RPH - 112
13
1" BSP
Klingerit
Klingerit
18
(1.4571)
(1.4571)
0,2 ... 3 m
125 ... 3000
0,2 ... 3 m
1
L1
Wiring of Low fail safe mode (L) Wiring of High fail safe mode (H)
Terminal block cover can be rotated in 90 steps to ensure appropriate cable
positioning.
4.1.2. Integral cable version R–3–2
The integrated cable has 4 wires. The connection to the AC network is done with
3 wires. Since there cannot be any unconnected wire all the 4 wires should be
connected to a junction box as seen below.
brown brown
L1
blue R blue R
N N
Before installation it is advised to try the operation of the level switch in a small black
L1
black
sample of material in order to set the proper density. Tightening of the model with green/yellow green/yellow
thread process connection should only be done with open end SW 41, SW 46 or Junction Junction
SW 55 spanner. box box
Marking
Wiring of Low fail safe mode (L) Wiring of High fail safe mode (H)
COM
4.1. TWO-WIRE AC R – 3 – 1 with connector
R – 3 – 2 with cable
PNP wiring
THE UNIT SHOULD NOT BE POWERED UP WITHOUT
GROUNDING AND EXTERNAL LOAD!
PNP output low (L) density, ( < 0.5 kg/dm3) H density, ( 0.5 kg/dm3) L density, ( < 0.5 kg/dm3)
brown + brown -
5. SET UP, ADJUSTMENT, PUTTING INTO OPERATION
white white Check wiring and setting of switches (if any). After powering up the vibrating fork
black R black R is operational. The operation is summarised in the table below
blue - blue +
grey grey Indicati
Power
Fork Operation on Output
Junction Junction supply
box box (LED)
Imin
UPOWER
OFF
Wiring of Low fail safe mode (L) Wiring of High fail safe mode (H) H RED
UPOWER
IN
L GREEN
brown + brown - Immersed
ON
white white R
YES
UPOWER
R black
IN
black
blue - blue + H GREEN
grey grey
Junction Junction
Imin
UPOWER
box box
L RED
Free
OFF
Wiring for L (Low fail safe operation) Wiring for H (High fail safe op)
UPOWER
Free H
NPN wiring low (L) density, ( < 0.5 kg/dm3) NONE or or NONE
immersed L
brown + brown -
white white R State of operation of the 2-wire DC version
black R black
blue - blue + Villa Indication (LED) Output
grey grey
Wiring for L (Low fail safe operation) Wiring for H (High fail safe op)
Free GREEN 9 1 mA
Junction
box
Junction
box
6. MAINTENANCE, REPAIR
The instrument does not require regular maintenance. In some
instances, however, the probe may need occasional cleaning to
Wiring for L (Low fail safe operation) Wiring for H (High fail safe op) remove surface deposits. This must be carried out gently,
without harming the probe.
PNP wiring low (L) density, (for solids: < 0.5 kg/dm3),
brown + brown + Repairs during or beyond the warranty period are carried out solely by the
white 24VDC
- white
24VDC
- manufacturer. Equipment sent back for repair should be cleaned or sterilised by
black IN
PLC
black
PLC
the User. The User must declare that the above has been carried out.
blue blue
grey COM grey 7. STORAGE CONDITIONS 8. WARRANTY
Junction Junction Ambient temperature: -25 to +60 °C NIVELCO provides warranty of 3 (three)
box box
Relative humidity: max. 98% years in compilance with details
described in the Warranty Card.
Wiring for L (Low fail safe operation) Wiring for H (High fail safe op)
rcm3014a0600h_08
November, 2014
NIVELCO reserves the right to change technical specifications without notice.