100% found this document useful (1 vote)
243 views2 pages

COUNTERFORT

The counterfort is analyzed using StaadPro software. It has a maximum span moment of 20 tonne-meters and maximum support moment of 27 tonne-meters. The section considered is 450x750 mm with reinforcement of 4-25mm tor steel bars on each face. Strength calculations confirm the section is adequate to resist the design forces with an axial load of 50 tonnes, moment of 20 tonne-meters, and shear of 25 tonnes. Reinforcement provided at the support face is also sufficient based on limit state design method charts.

Uploaded by

MALAY MRIDHA
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
243 views2 pages

COUNTERFORT

The counterfort is analyzed using StaadPro software. It has a maximum span moment of 20 tonne-meters and maximum support moment of 27 tonne-meters. The section considered is 450x750 mm with reinforcement of 4-25mm tor steel bars on each face. Strength calculations confirm the section is adequate to resist the design forces with an axial load of 50 tonnes, moment of 20 tonne-meters, and shear of 25 tonnes. Reinforcement provided at the support face is also sufficient based on limit state design method charts.

Uploaded by

MALAY MRIDHA
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 2

DESIGN OF COUNTERFORTS ( mkd C6, C9 & C12)

The counterforts are analysed by StaadPro software and the results are tabulated below :

REFER TO CW TANK FRAME.STD


(MEMB NO. 964 )
Maxm span moment = 20 tm (for load case 203)
Maxm support moment = 27 tm
Maxm shear at sides = 25 t
Axial load on column : 50 t (conservatively taken)
Counterforts at inside :

This beam is built monolithically with the side wall panel. Hence the flange action of the wall is considered while
performing uncracked stress check at waterace.
Beam section considered : 450 x 750 with reinft : 4 nos 25 tor tor bars at inface
and 4 nos 25 tor tor bars at outface
1400 1400
y 450 The design forces are :
inface Moment = 20tm ( with support moment
450 NA 450 Axial compr = 50t - tension at inface )
outace 300 Shear = 25t

19.63 cm2 19.63 cm2


Grade of conc. : M 25 Modular ratio = 10.98 Clear cover = 50 mm
For the above section,
Ae = 140 * 45 + 45 * 75 + 140 * 45
+ 9.98 * ( 19.63 + 19.63 )= 16366.8148 cm2
y=( 140 * 45 * 22.5 + 45 * 75 * 37.5 + 140 * 45
* 22.5 + 9.98 * ( 19.63 * 6.25 + 19.63 * 68.75 )/ Ae = 26 cm
INA= 1/12* 140 * 45 3+ 140 * 45 * 3.45 2
+ 1 / 12 * 45 * 75 3 +
45 * 75
* * 11.55 2+ 9.98 * ( 19.63 * 19.7 2
+ 19.63 * 42.8 2 )
+ 1/12* 140 * 45 3+ 140 * 45 * 3.45 2
= 4743386.902 cm4
Zinface = INA / 26 = 182789.48 cm3
Zoutface = INA / 49.1 = 96705.14 cm3
For axial compression Aeq = 45 * 75 + 8* 4.91 * 15.47 = 3983 cm2

sac,cal = 50 * 103 / Aeq = 12.6 kg/sq.cm < 60 kg/sq.cm


scbc,cal = 20 * 105/ Zoutface = 20.7 kg/sq.cm < 85 kg/sq.cm
scbt,cal = 20 * 105/ Zinface = 10.9 kg/sq.cm
Hence okay.

Strength Calculations at support :

For strength calculations refer charts 4.1 to 4.10 of Reinforced Concrete Design Handbook
by Chandra and Narayanan
Considering the section as rectangular, the following design parameters are obtained :-
P= 50 t. M= 20 tm
e = M/P = 0.4 m
sst = 1500 kg/cm2 .
scbc = 85 kg/cm2 . d1
modular ratio m = 10.98
Beam Section : B x D = 450 x 750
Clear cover = 50 mm
d1=750-50-10-25/2= 677.5 mm
d1 / D = 0.903

P / scbc.B.D = 50x10^3/(85x45x75)= 0.174


P.e / scbc.B.D2 = 50x0.4x10^5/(85x45x75^2)= 0.093
sst / (m.scbc ) = 1500/(10.98x85)= 1.61
Refer to Chart 4.1 of the Handbook , the zone falls below the dotted line
Hence refer to chart 4.6 ( as the stress in steel governs for strength design )
m.P / sst.B.D = 0.11
m.P.e / sst.B.D =
2
0.058
=> m.p = 0.01 => 0.001 => Ast reqd = 3.0738 cm2 .

Ast reqd per face = 1.537 cm2 . Provided Ast = 19.63 cm2 ./ face OK

Shear:
pt = 100x19.63/45x67.75= 0.644 % d= 677.5 mm
tc = 0.34 N/mm2. tc b.d.= 10.315 t.
With 4 Lgd 10 tor @ 200 c/c , Vus = 38.423 t.

Total shear capacity = 48.74 t. > Shear Force = 37.5t Hence okay.

AT BOTTOM SUPPORT
This face is checked in the Limit State Method as it is not in contact with water.

Moment at face of beam = 20 tm Axial load in column = 50t

Column size = 450 x 750 Clear cover = 40 mm

Pu / fck.B.D = 0.09 d' / D = 0.083

With actual provided reinforcement of 4 nos 25 tor tor bars at each face,p = 1.1637 % => p/fck = 0.0465

Refer to Chart 31 of SP-16, for p/fck = 0.047 Mu / fck.B.D2 = 0.06

=> Mu allowable = 38 tm > Mu actual = 30 tm Hence okay.