Cantilever Wall Analysis Input Data: Project

The document summarizes the analysis of a cantilever retaining wall. Key inputs include the wall geometry, soil properties, and design criteria. The analysis calculates earth pressures, checks stability against overturning and sliding, and verifies the bearing capacity of the foundation soil. It determines the wall is satisfactory for stability under permanent loading conditions.

Uploaded by

Branko Ilic
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
117 views

Cantilever Wall Analysis Input Data: Project

The document summarizes the analysis of a cantilever retaining wall. Key inputs include the wall geometry, soil properties, and design criteria. The analysis calculates earth pressures, checks stability against overturning and sliding, and verifies the bearing capacity of the foundation soil. It determines the wall is satisfactory for stability under permanent loading conditions.

Uploaded by

Branko Ilic
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

Cantilever wall analysis

Input data
Project
Description : POTPORNI ZID POS Z-1a, VISINA H=5.85 m
Date : 15.4.2019.
Settings
(input for current task)
Materials and standards
Concrete structures : EN 1992-1-1 (EC2)
Coefficients EN 1992-1-1 : standard
Wall analysis
Active earth pressure calculation : Coulomb
Passive earth pressure calculation : Caquot-Kerisel
Earthquake analysis : Mononobe-Okabe
Shape of earth wedge : Calculate as skew
Base key : The base key is considered as inclined footing bottom
Allowable eccentricity : 0,333
Verification methodology : Safety factors (ASD)
Safety factors
Permanent design situation
Safety factor for overturning : SFo = 1,50 [–]
Safety factor for sliding resistance : SFs = 1,50 [–]
Safety factor for bearing capacity : SFb = 1,00 [–]
Material of structure
Unit weight  = 24,00 kN/m3
Analysis of concrete structures carried out according to the standard EN 1992-1-1 (EC2).

Concrete : C 25/30
Cylinder compressive strength fck = 25,00 MPa
Tensile strength fctm = 2,60 MPa
Longitudinal steel : B500
Yield strength fyk = 500,00 MPa
Geometry of structure
Coordinate Depth
No.
X [m] Z [m]
1 0,00 0,00
2 0,00 5,40
3 3,40 5,40
4 3,40 5,80
5 -0,60 5,80
6 -0,60 5,40
7 -0,40 5,40
8 -0,40 0,00
The origin [0,0] is located at the most upper right point of the wall.
Wall section area = 3,76 m2.

1
Name : Geometrija Stage - analysis : 1 - 0
Description : Poprečni presek potpornog zida

0,40

5,40 0,00:1
5,80 5,80

0,20 3,40

0,40
Name : Geometry Stage - analysis : 1 - 0

4,00

2
Basic soil parameters
ef cef  su 
No. Name Pattern
[°] [kPa] [kN/m3] [kN/m3] [°]
Sandy clay (CS), stiff consistency, Sr >
1 26,00 0,00 19,00 9,00 12,00
0,8

2 Gravelly silt (MG), firm consistency 30,00 8,00 20,00 10,00 15,00

Soil parameters to compute pressure at rest


Type ef  OCR Kr
No. Name Pattern
calculation [°] [–] [–] [–]
Sandy clay (CS), stiff consistency, Sr >
1 cohesionless 26,00 - - -
0,8

2 Gravelly silt (MG), firm consistency cohesive - 0,35 - -

Soil parameters
Sandy clay (CS), stiff consistency, Sr > 0,8
Unit weight :  = 19,00 kN/m3
Stress-state : effective
Angle of internal friction : ef = 26,00 °
Cohesion of soil : cef = 0,00 kPa
Angle of friction struc.-soil :  = 12,00 °
Soil : cohesionless
Saturated unit weight : sat = 19,00 kN/m3

Gravelly silt (MG), firm consistency


Unit weight :  = 20,00 kN/m3
Stress-state : effective
Angle of internal friction : ef = 30,00 °
Cohesion of soil : cef = 8,00 kPa
Angle of friction struc.-soil :  = 15,00 °
Soil : cohesive
Poisson's ratio :  = 0,35
Saturated unit weight : sat = 20,00 kN/m3

Geological profile and assigned soils


Layer
No. Assigned soil Pattern
[m]

1 5,80 Sandy clay (CS), stiff consistency, Sr > 0,8

2 - Sandy clay (CS), stiff consistency, Sr > 0,8

Foundation
Type of foundation : strip foundation
Soil of foundation - Gravelly silt (MG), firm consistency
Geometry
Foundation thickness h = 0,20 m
Offset left bl = 0,30 m
Offset right bp = 0,30 m
Terrain profile
Terrain behind the structure is flat.

3
Water influence
Ground water table is located below the structure.

Input surface surcharges


Surcharge Mag.1 Mag.2 Ord.x Length Depth
No. Action
new change [kN/m2] [kN/m2] x [m] l [m] z [m]
1 Yes variable 3,00 0,00 5,00 on terrain
No. Name
1 Live load
Resistance on front face of the structure
Resistance on front face of the structure: not considered
Soil on front face of the structure - Sandy clay (CS), stiff consistency, Sr > 0,8
Soil thickness in front of structure h = 0,90 m
Terrain in front of structure is flat.

Earthquake
Factor of horizontal acceleration Kh = 0,1000
Factor of vertical acceleration Kv = 0,0000
Water below the GWT is restricted.

Settings of the stage of construction


Design situation : permanent
The wall is free to move. Active earth pressure is therefore assumed.

Verification No. 1
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0,00 -1,87 90,24 1,08 1,000
Earthq.- constr. 9,02 -1,87 0,00 1,08 1,000
Weight - earth wedge 0,00 -2,21 175,74 1,73 1,000
Earthquake - soil wedge 17,57 -2,21 0,00 1,73 1,000
Active pressure 122,94 -1,96 176,24 2,90 1,000
Earthq.- act.pressure 24,42 -3,87 38,93 1,82 1,000
Live load 3,25 -2,73 4,62 2,35 1,000
Live load 0,00 -5,80 0,08 0,61 1,000
Verification of complete wall
Check for overturning stability
Resisting moment Mres = 994,33 kNm/m
Overturning moment Movr = 399,90 kNm/m

Safety factor = 2,49 > 1,50


Wall for overturning is SATISFACTORY

Check for slip


Resisting horizontal force Hres = 300,08 kN/m
Active horizontal force Hact = 177,20 kN/m

Safety factor = 1,69 > 1,50

4
Wall for slip is SATISFACTORY

Overall check - WALL is SATISFACTORY

Name : Verification Stage - analysis : 1 - 1

7 1
3
4
1
2 5

90
0,20 +x soil
Bearing capacity of foundation
Design load acting at the center of footing bottom 2

Moment 0,30 Norm. force 0,30 Shear Force Eccentricity Stress


No.
[kNm/m] +z [kN/m] [kN/m] [–] [kPa]
1 377,25 485,84 177,20 0,194 198,54
Service load acting at the center of footing bottom
Moment Norm. force Shear Force
No.
[kNm/m] [kN/m] [kN/m]
1 377,25 485,84 177,20
Verification of foundation soil
Stress in the footing bottom : rectangle

Eccentricity verification
Max. eccentricity of normal force e = 0,194
Maximum allowable eccentricity ealw = 0,333
Eccentricity of the normal force is SATISFACTORY

Verification of bearing capacity


Max. stress at footing bottom  = 198,54 kPa
Bearing capacity of foundation soil Rd = 200,00 kPa
Safety factor = 1,01 > 1,00
Bearing capacity of foundation soil is SATISFACTORY

Overall verification - bearing capacity of found. soil is SATISFACTORY

5
Name : Bearing cap. Stage - analysis : 1 - -1

2,45
198,54

198,54

Dimensioning No. 1
Wall stem check - front reinf.
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0,00 -2,70 51,83 0,20 1,000
Earthq.- constr. 5,18 -2,70 0,00 0,20 1,000
Pressure at rest 155,51 -1,80 0,00 0,40 1,000
Earthquake - pressure at rest 55,38 -2,70 0,00 0,40 1,000
Live load 6,37 -3,21 0,00 0,40 1,000
Wall stem check - front reinf.
Front reinforcement is not required.

Wall stem check - back reinf.


Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0,00 -2,70 51,83 0,20 1,000
Earthq.- constr. 5,18 -2,70 0,00 0,20 1,000
Pressure at rest 155,51 -1,80 0,00 0,40 1,000
Earthquake - pressure at rest 55,38 -2,70 0,00 0,40 1,000
Live load 6,37 -3,21 0,00 0,40 1,000
Wall stem check - back reinf.
Wall check at the construction joint 5,40 m from the wall crest
Reinforcement and dimensions of the cross-section
14 prof. 18,0 mm, cover 30,0 mm
Cross-section width = 1,00 m

6
Cross-section height = 0,40 m
Reinforcement ratio  = 0,99 % > 0,14 % = min
Position of neutral axis x = 0,10 m < 0,22 m = xmax
Ultimate moment MRd = 495,51 kNm > 463,75 kNm = MEd
Cross-section must be reinforced by shear reinforcement with minimal area of 629,9 mm 2/m.
Cross-section is SATISFACTORY.

Wall heel check


Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0,00 -0,20 32,64 2,30 1,000
Weight - earth wedge 0,00 -2,21 175,74 1,73 1,000
Active pressure 122,94 -1,96 176,24 2,90 1,000
Live load 3,25 -2,73 4,62 2,35 1,000
Contact stress 0,00 0,00 -339,99 1,62 1,000
Gravity surch. 1 0,00 -5,80 0,09 0,62 1,000
Wall heel check
Reinforcement and dimensions of the cross-section
14 prof. 16,0 mm, cover 30,0 mm
Cross-section width = 1,00 m
Cross-section height = 0,40 m
Reinforcement ratio  = 0,78 % > 0,14 % = min
Position of neutral axis x = 0,09 m < 0,22 m = xmax
Ultimate shear force VRd = 203,62 kN > 49,34 kN = VEd
Ultimate moment MRd = 398,10 kNm > 319,29 kNm = MEd
Cross-section is SATISFACTORY.

Name : Dimensioning Stage - analysis : 1 - 1


Bending moment
Max MRd2 = 495,51 kNm Shear force
Max MRd1 = -1E30 kNm Max VRd = 219,98 kN
MEd = 463,75 kNm VEd = 222,44 kN
0,00 495,51 0,00 219,98

7 prof. 8,0mm,cover 30,0mm 14 prof. 18,0mm,cover 30,0mm


5,80 5,80

14 prof. 16,0mm,cover 30,0mm


463,75
495,51 219,98
222,44
+x
0 500,00 0 300,00
[kNm] [kN]

+z