Comparative Analysis of B.P. 220, P.D. 1096, P.D. 957 and Fire Code
Comparative Analysis of B.P. 220, P.D. 1096, P.D. 957 and Fire Code
Toilet & Bath N/A N/A N/A 1.20 sq. m w/ min. N/A
dimension of 0.90
m
Kitchens N/A N/A N/A 3.00 sq. m w/ min. N/A
dimension of 1.50
m
SETBACKS B.P 220 E. H B.P 220 S. H P.D 957 P.D 1096 Fire Code
RESIDENTIAL B.P 220 E. H B.P 220 S. H P.D 957 P.D 1096 Fire Code
REQUIREMENTS
Entrance and Exit At least 1 entrance At least 1 entrance At least 1 entrance At least 1 entrance Refer to Fire
& 1 exit & 1 exit & 1 exit & 1 exit Code
Specifications
Occupant Load No. of units No. of units 18.6 sq. m/ person 18.6 sq. m/ person N/A
Multiplied by 6 Multiplied by 6
LIGHT AND B.P 220 E. H B.P 220 S. H P.D 957 P.D 1096 Fire Code
VENTILATION
Min. Ceiling Height for Habitable 2.40 m 2.40 m 2.40 m – Artificial 2.40 m – Artificial 2.30 m
Rooms
Ventilation Ventilation
2.70 m – Natural 2.70 m – Natural
Ventilation Ventilation
Min. Ceiling Height for Buildings 2.00 m -1.80 m - 2.00 m-1.80 m - 2.00 m-1.80 m - 2.70 m – 1st 2.30 m 2.13 m
Mezzanine Mezzanine Mezzanine Storey
2.40 m – 2nd
Storey
2.10 m –
Succeeding
Storeys
1.80 m –
Mezzanine
+Sum of Areas of Openings in any Less than 25% of Less than 25% of Less than 50% of Less than 50% of N/A
Storey
total area of the wall total area of the wall total area of the total area of the
on that storey on that storey wall on that storey wall on that storey
Window Openings At least 10% of the At least 10% of the At least 10% of the At least 10% of N/A
the
floor area floor area floor area
floor area
Eaves over required windows N/A N/A N/A At least 750 mm N/A
Passageway from At least 1.20 m At least 1.20 m At least 1.20 m At least 1.20 m N/A
Inner Court
SIDEWALKS AND B.P 220 E. H B.P 220 S. H P.D 957 P.D 1096 Fire Code
ARCADES
Min. of width of sidewalk 1.00 m for major road 1.00 m for major road 1.00 m for major 1/6 of R.O.W N/A
& 500 mm minor road & 500 mm minor road road & minor roads
Plant Strip 1.00 m for major road 1.00 m for major road 1.00 m for major 800 mm for N/A
& 500 mm minor road & 500 mm minor road road & minor roads sidewalks
exceeding 2.00 m
in width
PARKING B.P 220 E. H B.P 220 S. H P.D 957 P.D 1096 Fire Code
Size of Parking Slot 2.40 x 5.00 m 2.40 x 5.00 m 2.40 x 5.00 m 2.40 x 5.00 m N/A
(perpendicular & (perpendicular & (perpendicular & (perpendicular &
diagonal) diagonal) diagonal) diagonal)
2.00 x 6.00 m(parallel) 2.00 x 6.00 m(parallel) 2.00 x 6.00 2.00 x 6.00 m
m(parallel) (parallel)
Low-income single detached living Pooled Parking 1 slot/ Pooled Parking 1 slot/ Pooled Parking 1 Pooled Parking 1 N/A
units w/ individual lot size not more 10 units 10 units slot/ 10 units slot/ 10 units
than 100 sq. m
50 sq. m below 1 slot / 20 units 1 slot / 20 units 1 slot /8 units 1 slot /8 units N/A
50-100 sq. m 1 slot/ 4 units 1 slot/ 4 units
100 sq. m above 1 slot/ 1 unit 1 slot/ 1 unit
DOORS B.P 220 E. H B.P 220 S. H P.D 957 P.D 1096 Fire Code
Minimum Width Main door: 0.80 m Main door: 0.80 m N/A 900 mm 710 mm
Bedroom: 0.70 m Bedroom: 0.70 m
Bathroom: 0.60 m Bathroom: 0.60 m
Maimum Width N/A N/A N/A 1200 mm 1220 mm
OPEN SPACE B.P 220 E. H B.P 220 S. H P.D 957 P.D 1096 Fire Code
REQUIREMENTS
Interior Lots 50% Residential 50% Residential 50% Residential 50% Residential N/A
25% Others 25% Others 25% Others 25% others
Inside Lots 20% Residential 20% Residential 20% Residential 20% Residential N/A
15% Others 15% Others 15% Others 15% others
Corner/Through 10% Residential 10% Residential 10% Residential 10% Residential N/A
Lot 5% Others 5% Others 5% Others 5% others
Lot bounded by 5% for all Occupancies 5% for all Occupancies 5% for all 5% for all N/A
Occupancies occupancies
streets on 3 sides
STAIRWAYS FOR B.P 220 E. H B.P 220 S. H P.D 957 P.D 1096 Fire Code
BUILDINGS
Riser 200 mm 200 mm 200 mm 200 mm 190 mm class
A 200 mm
class B
Tread 250 mm 250 mm 250 mm 250 mm 250 mm class
A
230 mm class
B
Min. stair width: Occupant load of 10- N/A N/A N/A 750 mm N/A
below
Min. stair width: Occupant load of 10- 900 mm 900 mm 900 mm 900 mm N/A
50
Min. stair width: Occupant load of 50 - 1.00 m 1.00 m 1.10 m 1.10 m N/A
above
Dimension of Landings in the direction Equal to the Equal to the Equal to the Equal to the width 1.12 m
of travel of
width of the width of the width of the
the stairway
stairway stairway stairway
Height of handrails 800-1200 mm from 800-1200 mm from 800-900 mm from 800-900 mm from 760-895 mm
the nosing the nosing the nosing the nosing from the
nosing
EXITS B.P 220 B.P 220 S. H P.D 957 P.D 1096 Fire Code
E.H
Min. exit door width 800 mm 800 mm 700 mm 700 mm 710 mm
Dead ends Max. of 12.00 Max. of 12.00 m Max. of 12.00 m Max. of 6.00 m Max. of 6.00 m
m
Occupant Load of At least 1 exit At least 1 exit At least 1 exit At least 1 exit At least 2 exits
less than 10
Occupant Load of N/A N/A At least 2 exits At least 2 exits N/A
10-499
ELEVATORS B.P 220 B.P 220 S. H P.D 957 P.D 1096 Fire Code
E.H
Various Elevator Required for muti-family dwellings and In apartments or Required for
Requirements condominiums 6 sotreys of higher. condominiums 5 healthcare
Follow NBC
Follow standards in NBC and BP 344 storeys or higher, occupancies
at least 1 two storeys or
passenger elevator higher
shall be kept on
24 hour constant
service