100% found this document useful (1 vote)
2K views2 pages

Pic152a Vi

This document summarizes the features and specifications of the PIC152A-VI process indicator. It has a 4-digit 7-segment LED display, LED status indicators, and accepts thermocouple, RTD, or analog inputs. It has 2 alarm outputs, 24V DC sensor supply, and optional retransmission output. Certification is in process. It is intended for industrial temperature measurement and meets relevant EMI/EMC standards.

Uploaded by

iyappan5016
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
2K views2 pages

Pic152a Vi

This document summarizes the features and specifications of the PIC152A-VI process indicator. It has a 4-digit 7-segment LED display, LED status indicators, and accepts thermocouple, RTD, or analog inputs. It has 2 alarm outputs, 24V DC sensor supply, and optional retransmission output. Certification is in process. It is intended for industrial temperature measurement and meets relevant EMI/EMC standards.

Uploaded by

iyappan5016
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

PIC152A-VI Process Indicator

Features :
! 4 Digits, 7 Segment LED Single Display
! LED Status Indicator : Alarm ON
! TC / RTD / Analog Input
o
! C / oF Selectable
! 2 Alarm Outputs
! 24V DC Sensor Supply
! Retransmission Output
48 x 96mm
Certification : in process

Display Specifications Environmental Specifications

Display 4 Digits 7 Segment LED Single Display Temperature Operating : 0 to 50oC (32 to 122oF)
Height of Display 0.5” Storage : -20 to 75oC (-4 to 167oF)
LED Indications Alarm ON (2 Nos) Humidity (non-condensing) 85% RH
Weight 220 gms

Input Specifications
Mechanical Specifications
Inputs Thermocouple (J, K, T, R, S)
RTD (PT100) Mounting Panel
DC Analog inputs (-5 to 56mV, 0 to 10V,
0/4 to 20mA) Weight 220 gms
Resolution 1 / 0.1o for TC / RTD only
( Fixed 1° resolution for R & S type TC) Dimensions
Decimal point position selectable :
1 / 0.1 / 0.01 / 0.001 for analog input
Indication Accuracy For TC inputs : 0.25% of F.S. ±1o 50 45 46
For R & S inputs : 0.5% of F.S. ±2o
(20 min of warm up time for TC inputs) 98 76 92
3
For RTD input : 0.1% of F.S. ±1o
For Analog inputs : ±0.5% of F.S., ± 1 digit
(F.S. = Full Scale)
Temperature Unit o
C / oF selectable Terminal Connections

1) 230V SUPPLY
Output Specifications

Alarm
I

Relay Contact (SPDT) 5A @ 250V AC resistive


Retransmission (Optional) 0 / 4 to 20 mA DC, 0 to 5 - 10V DC, 0 - 5V DC
Sensor Supply 24V DC, 30mA

~
Functional Specifications

Alarms 2
Alarm Modes High alarm, Low alarm, Band, Fail output 2) 24V SUPPLY
and Fault diagnosis
Hysteresis 0.1 to 99.9o
I

Annunciator Programmable
Reset Action Automatic or Latched

Auxiliary Supply Specifications

Supply Voltage 85 to 270V AC / DC (50 / 60Hz)


Optional : 24V DC
Power Consumption 6 VA max @ 230V AC

www.selec.com 1
PIC152A-VI Process Indicator

Compliance Ordering Information


Applicable EMI / EMC Standards COMMUNICATION
PRODUCT CODE RETRANSMISSION SUPPLY VOLTAGE CERTIFICATION
Product Standard : IEC 61326-1 (RS485)
Category Standards Compliance PIC152A-VI Universal --- 85 - 270V AC / DC -

ESD Immunity IEC 61000-4-2 Level III PIC152A-VI-CE Universal --- 85 - 270V AC / DC

+/- 2 kV common mode,


Surge Immunity IEC 61000-4-5 Mounting Accessories (Supplied with units)
+/- 1 kV differential mode
Level III, 80 to 1000MHz Clamp side with screw assembled
Radiated Susceptibility IEC 61000-4-3 Level II, 1.4GHz to 2GHz
Level I, 2GHz to 2.7GHz
Conducted Susceptibility IEC 61000-4-6 Level II Input Ranges (For TC / RTD input)
Dips : 0% residual voltage /
1 cycle (Criteria B), 40% residual voltage / Resolution Ranges
10 cycles 50Hz / 12 cycles 60Hz
Voltage Dips and Sensor Type
IEC 61000-4-11 (Criteria C)70% residual voltage / 1 0.1
Interruptions 25 cycles50Hz / 30 cycles 60Hz
o
(Criteria C) C -150 to 850 -150 to 850
Interruptions : 0% residual voltage / Pt100
o
250 cycles 50Hz / 300 cycles 60Hz F -238 to 1562 -199 to 999
(Criteria C)
o
Conducted Emission CISPR-11 C -199 to 750 -199 to 750
J o
Radiated Emission CISPR-11 F -328 to 1382 -199 to 999
Electrical Fast Transient IEC 61000-4-4 Level III o
C -199 to 1350 -199 to 999
K
o
F -328 to 2462 -199 to 999
o
C -199 to 400 -199 to 400
T
o
F -328 to 750 -199 to 750
o
C 0 to 1750 N/A
R&S
o
F 32 to 3182 N/A