CNT-400

CNT-400, CNT® 50 Ohm Braided Coaxial Cable, variable, black PE jacket

Product Classification
Brand CNT®
Product Series CNT-400
Product Type Braided coaxial cable
 

Construction Materials
Jacket Color Black
Jacket Material Non-halogenated PE
Braid Material Tinned copper
Shield Tape Material Aluminum
Dielectric Material Foam PE
Inner Conductor Material Copper-clad aluminum wire
 

Dimensions
Cable Weight 0.10 kg/m
Diameter Over Dielectric 7.240 mm   |   0.285 in
Diameter Over Jacket 10.290 mm   |   0.405 in
Diameter Over Tape 7.391 mm   |   0.291 in
Inner Conductor OD 2.7400 mm   |   0.1079 in
Nominal Size 0.400 in
Outer Conductor OD 8.080 mm   |   0.318 in
 

Electrical Specifications
Cable Impedance 50 ohm
Capacitance 78.0 pF/m   |   24.0 pF/ft
dc Resistance, Inner Conductor 4.690 ohms/km   |   1.430 ohms/kft
dc Resistance, Outer Conductor 5.610 ohms/km   |   1.710 ohms/kft
dc Test Voltage 2500 V
Jacket Spark Test Voltage (rms) 4000 V

page 1 of 3
June 12, 2019

©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: January 22, 2019
CNT-400

Maximum Frequency 16.20 GHz


Operating Frequency Band 30 – 6000 MHz
Peak Power 16.0 kW
Shielding Effectiveness >90 dB
Velocity 85%
 

Environmental Specifications
Installation Temperature -40 °C to +85 °C (-40 °F to +185 °F)
Operating Temperature -40 °C to +85 °C (-40 °F to +185 °F)
Storage Temperature -70 °C to +85 °C (-94 °F to +185 °F)
 

General Specifications
Cable Type CNT-400
Braid Coverage 90% braid
 

Mechanical Specifications
Bending Moment 0.7 N-m   |   0.5 ft lb
Flat Plate Crush Strength 0.7 kg/mm   |   40.0 lb/in
Minimum Bend Radius, Single Bend 25.40 mm   |   1.00 in
Tensile Strength 73 kg   |   160 lb

Electrical Performance
Frequency Attenuation (dB/100 m) Attenuation (dB/100 ft)
30 MHz 2.49 0.76
50 MHz 3.18 0.97
150 MHz 4.92 1.50
220 MHz 6.23 1.90
450 MHz 8.86 2.70
900 MHz 12.80 3.90
1500 MHz 16.70 5.10
1800 MHz 18.40 5.60
2000 MHz 19.40 5.90
2400 MHz 21.65 6.60
2500 MHz 22.00 6.70
3000 MHz 24.60 7.50
4000 MHz 28.87 8.80
4500 MHz 30.84 9.40
5000 MHz 32.81 10.00
5200 MHz 33.46 10.20
5500 MHz 34.78 10.60
5800 MHz 35.76 10.90
6000 MHz 36.42 11.10

page 2 of 3
June 12, 2019

©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: January 22, 2019
CNT-400

Regulatory Compliance/Certifications
Agency Classification
RoHS 2011/65/EU Compliant
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system
China RoHS SJ/T 11364-2014 Below Maximum Concentration Value (MCV)