Sop For Cep Pump Start /Stop/Change Over /isolation Procedure

This document outlines standard operating procedures for starting, stopping, changing over, and isolating CEP pumps. It provides steps to check pump parameters like condenser level and valve positions. When starting a pump, operators should check the direction of rotation and monitor pressure, vibration, current, and bearing temperature. The document also describes putting pumps in auto or manual mode, and closing necessary valves and drains when stopping or isolating a pump.

Uploaded by

book1616
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views

Sop For Cep Pump Start /Stop/Change Over /isolation Procedure

This document outlines standard operating procedures for starting, stopping, changing over, and isolating CEP pumps. It provides steps to check pump parameters like condenser level and valve positions. When starting a pump, operators should check the direction of rotation and monitor pressure, vibration, current, and bearing temperature. The document also describes putting pumps in auto or manual mode, and closing necessary valves and drains when stopping or isolating a pump.

Uploaded by

book1616
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 2

SOP FOR CEP PUMP START /STOP/CHANGE OVER /ISOLATION

PROCEDURE

 Check the condenser hot well level is normal


 Ensure the feeder is normalized and push button released condition
 Check the suction valve, balancing valve, discharge isolation valve is open
condition
 Ensure the minimum recirculation isolation and control valve is open condition
 Ensure the hot well level control valves close and isolation valve is open
condition
 Ensure the line drains and vents are closed
 Check the bearing oil level is normal
 Start the pump in local/remote mode and check the direction of rotation.
 To check the current ,vibration , pressure, ∆p and bearing temp
 If all the parameters are normal gradually open the hot well level control valve to
maintain the hot well level
 Adjust the level control valve and recirculation control valve to maintain the
header pressure 12 kg/cm2 and hot well level 350mm.
 Record the pressure, vibration, current, ∆p and bearing temp

AUTO MODE SELECTION


 Check the stand by pump suction ,discharge and balancing valves are open
 Ensure the standby pump feeder normalized condition
 All the parameters of the running pump is normal select the standby pump in auto
mode

PUMP CHANGEOVER PROCEDURE


 change the standby pump in auto mode to manual mode
 check the standby pump feeder normalized condition
 check the standby pump suction valve, discharge and balancing valve open
condition
 start the standby pump in remote / local mode and check the direction of rotation
 check the pressure, current, vibration, ∆p and bearing temp
 If all the parameters are normal stop the previous running pump.
 select the standby pump in auto mode from manual mode
PUMP STOP PROCEDURE
 Both the CEP pump can be stopped, if the STG stopped and the hot well temp
nearer to atmospheric temp.
 Ensure the above mentioned conditions are satisfied stop the pump

PUMP ISOLATION PROCEDURE


 Ensure the pump stopped condition
 Check the feeder was isolated and LOTO applied
 Close the suction ,discharge and balancing valve
 Open the pump drain valve

PREPARED BY CHECKED BY APPROVED BY


J.PUGAZHENDHI E.VINOTH KUMAR