0% found this document useful (0 votes)
526 views

NPCP Chapter 4

The document outlines plumbing fixture requirements and standards across several sections. Key requirements include fixtures being made of durable, non-absorbent materials with smooth surfaces; special fixtures allowing for materials like soapstone or corrosion-resistant steel; overflows being connected to the inlet side of traps; minimum strainer and connection sizes; floor drains and shower receptors meeting material and installation standards; and fixtures complying with the national building code.

Uploaded by

Ryan Caduyac
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
526 views

NPCP Chapter 4

The document outlines plumbing fixture requirements and standards across several sections. Key requirements include fixtures being made of durable, non-absorbent materials with smooth surfaces; special fixtures allowing for materials like soapstone or corrosion-resistant steel; overflows being connected to the inlet side of traps; minimum strainer and connection sizes; floor drains and shower receptors meeting material and installation standards; and fixtures complying with the national building code.

Uploaded by

Ryan Caduyac
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

PLUMBING FIXTURES

SECTION 401 MATERIALS GENERAL REQUIREMENTS


- Quality of fixtures
should be Dense, Durable and Non Absorbent
should also have Smooth and Impervious Surfaces
- Porcelain Enamel Surfaces
acid resistant
- Water Closet (public)
elongated type

SECTION 402 MATERIALS - ALTERNATIVES


- Special use fixtures
Soapstone , Chemical stoneware lined with Lead, Copper
base alloy, Nicker copper alloy, Corrosion resisting steel
- Restaurant Kitchen Sinks
G.I. #16 U.S. B & S or 16mm thick

SECTION 403 OVERFLOWS


- overflow outlet waste
arranged so that the standing water inside the fixture cannot
rise inside the overflow way
- overflow pipe
shall be connected to the inlet side of the fixture trap
- Water closet or Urinal flash
shall discharge into the bowl served

SECTION 404 STRAINERS AND CONNECTIONS


- Strainers
sum of all the areas of the perforations of the strainer
is equal to the equivalent outlet area
- Connections
*slip joint - access panel or utility atleast 0.3 meter
Seamless drawn brass not less than
G.I. #20 B & S or 0.8 mm thick
Tailpiece, continuous waste or overflow shall
*not less than 38 mm O.D Sinks, Dishwashers, Laundry, Tubs
Bathtubs and Urinals
*not less than 32 mm O.D. Lavatories and Drinking Fountains

Note
Brass or Copper shall not be used for Urinal Tailpiece
or Trap
SECTION 405 PROHIBITED FIXTURES
- Water Closet (prohibited)
inivisible seals, unventilate space and having walls
which are not thoroughly washed at each discharge
- Drinking Fountain
shall not be installed on Public toilet Rooms
- Fixed wooden, Concrete, Tile, WASH TRAYS or SINKS
shall not be installed on buildings for human habitation

SECTION 406 SPECIAL FIXTURES AND SPECIALTIES


- Water Connections on all special fixtures shall be protected from
Back Siphonage
- Waste Water drain for "SACRARIUM" shall be discharge direct to the
ground
SACRARIUM length 346 mm
width 286 mm
height 152 mm

- Approved by admin authority

SECTION 407 INSTALLATION


- Cleaning
0.30 meters - distance of water closet to wall for easy access
on repair and cleaning
- Joints
joint bet. Fixture and wall shall be WATERTIGHT
- Screwing Fixtures
Screws and Expansion bolts - Corrosion resistant
- Wall hung fixtures
shall be supported by Metal Supporting Members
- Setting Wall Fixtures
*urinal 0.30 m 0.60 m min.
*water Closet 0.375 m 0.75 m min.
- Supply Fittings
shall be installed to prevent backflow

SECTION 408 URINALS


- Automatic Flashing Tanks
for flashing more than 1 (one) urinals
- Flushometer Valves
manually controlled flushometer valve shall be used for flashing
1 (one) urinal only

SECTION 409 FLOOR DRAINS AND SHOWER STALLS


- Floor Drain
considered plumbing fixtures
- Shower receptor
must be made of Vitrified China or Earthenware, Ceramic
tile, Porcelain-enameled metal
- Shower receptor of an approved type to have a DAM, CURB
or THRESHOLD which is 25.4 mm (1") lower than outside floor
- Dam or Threshold
depth 51 mm to 228 mm (2' to 9")
slope 2% to 4%
width 559 mm wide door (min.)

Note
The minimum distance bet.the Door or Entry to the drain
opening is 1.2 meters
- Shower Compartments
Area 0.6 m2 (min.)
Encompassing Circle 762 mm diameter
height 1.78 meters (min.)
- Floors of public rooms
shall be non skid surface
- Gutters in public or gang showers shall have pounded corners and
a slope of 2% towards the drain
- Drain in gutters shall be spaced not more than 4.9 meters
- Maximum Temperature of Hot Water
48.48 degrees celsius
- Lead and Copper Sub pan Linings
*materials 6 kgs.of asphalt felt
*unit weight not less than 19.6 kg/m3
*thickness for copper Gauge #24 B&S or 0.5 mm thick
pans
- Joints
Lead pans burned
Copper pans soldered or brazed

SECTION 410 PLUMBIING FIXTURE REQUIRED


- as prescribed by the National Building Code

SECTION 411 WHIRLPOOL BATHTUB


- Requirements
*removable panel for access to the pump
*Circulation pump location should be above the crown weir
*Pump and Circulation piping shall be Self Draining
* Suction fitting should by approved on the listed standards