100% found this document useful (3 votes)
2K views5 pages

Ewis

This document contains questions and answers about aircraft electrical wiring interconnection systems (EWIS). Some key points: 1. EWIS refers to the wiring, cables, and termination/connection devices on an aircraft. Boeing uses tooling like the Standard Wiring Practices Manual (SWPM) to identify connector part numbers and repair procedures. 2. The main organization that conducts research on aircraft electric wires is the Aviation Rulemaking Advisory Committee (ARAC). 3. Common causes of EWIS failures include electrostatic discharge, corrosion of bonding and grounding systems, and damage from lack of following maintenance procedures. Regular inspections and crew training are important to prevent failures.

Uploaded by

Mehdi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (3 votes)
2K views5 pages

Ewis

This document contains questions and answers about aircraft electrical wiring interconnection systems (EWIS). Some key points: 1. EWIS refers to the wiring, cables, and termination/connection devices on an aircraft. Boeing uses tooling like the Standard Wiring Practices Manual (SWPM) to identify connector part numbers and repair procedures. 2. The main organization that conducts research on aircraft electric wires is the Aviation Rulemaking Advisory Committee (ARAC). 3. Common causes of EWIS failures include electrostatic discharge, corrosion of bonding and grounding systems, and damage from lack of following maintenance procedures. Regular inspections and crew training are important to prevent failures.

Uploaded by

Mehdi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

1- For Temp 150c Boeing Is Use ….

Wire
√A.ETFE (Tefzel)
B.Kapton
C.Ptfe
2.Ewis Meaning Contains:
A. Test Cables
B.Lru Wiring
√C. Termination Devices On A/C
3.Tooling – Connector Part Number- Aplices Will Foun In:
√A.SPWM
B.WDM
C. ESPM
4.Electro Static Discharge Sensitive Devices
√A. Can Have Damage From ESD
B. Can Not Have Damage From ESD
C. Not Need To Do ESD Protection.
5.Which Is Correct
√A. EWIS Contains Any Data Communication Wiring
B. EWIS Doesn’t Contain Any Data Communication Wiring
C. EWIS Doesn’t Contain Any Wiring Clamps.
6.Which Organization Is The Organization To Conduct Research On The
Electric Wires On Airplanes?
A.ICA
√B.ATSRAC
C.EZAP
7.Swpm Use By
A. Airbus
√B. Boeing
C.STC
8.Metod Of Firmly Attaching A Terminal To An Electrical Conductor By
Pressure Forming Is Call. Page 116
√A. Crimping
B. Jumper
C. Splicing
9.Static Bleed Of, Proper Operation Of The Circuit Is Function Of:
A. Shield Wiring
√B. Bonding
C. Shield Grounding
10.Where The Full Environmental Seal Is Required We Use:
A. Preinsulated Butt Splice
B. Normal Splice
√C. Moisture Proof Splice
11.The Manual Contains The Procedure For The Maintenance Of The
Ewis Component Is:
√A.SWPM
B.Wl
C.WDM
12.For List of Grounds & Splices In A/C Wiring We Use:
A.Wdel (Wiring Diagram Equipment Lise)
√B.Ch 91 Of WDM
C.Ch 20 Of WDM
13.Visual Inspection Reliability Depends On:
A.Both Of A&C √
B.Recognizing What You See Is A Defect
C. Seeing The Defect
14.The Resistance Of An Equal Section Of Wire
A. Equal Or More Than
B. Equal
√ C. Equal Or Less Than Equal
15.Catastrophic Failure Caused By:
A. Chamges In Basic Characteristics
B. Degradation Of Performance
√C. Electro Static Discharge
16.Which One Is Boeing Connector P/N:
A. En 3155- 019f
√B. Bacc63ae
C. ASNE 0261 CF
17.Which One Is Correct About Electrostatic Charges
A. Are Stored On The Surfaces Of Physical Object
B. Are Stored On The Human Body
√C. All Correct
18.Aircraft Schematic Manual Is A Part Of:
√A. Wdm
B. Awl
C. Awm
19.The Main Bend Radius Of Wire Harness Is The Same As The Min Bend
Radius Of The …… Wire Or Cable In The Harness:
A. Largest Radius
B. Shortest Diameter
√C. Largest Diameter
20.Aircraft Schematic Manual Is A Part Of:
√A.WDM
B. Awl
C. Awm
21.Whic Is Correct?
A. A Repair Must Be Put In A Conduct
B. A Repair Must Be Put On The Corner
√C. A Repairs Must Not Be Put On The Wire Bent
22.How Is The Breakdown Of A Damaged Cable Unlocked?
A. Amm
√B. Espm
C.Wdm
23.How Megger Inserted Into Circuit?
A. Series With The Source
B.Parallel With The Source
√C.No Power On Circuit, Between Points
24.Which One Is Not Related To Ewis Controls?
√A. Fiber Optics
B. Terminals
C .Connectors
25.Which Is Correct?
A.A Repair Must Be Put On The Corner
√B. A Repairs Must Not Be Put On The Wire Bent
C. A Repair Must Be Put In A Conduit
26.The Forming Of Satisfactory Crimp Depends On:………….
A.Conductor, Crimp Barrel
√B. Correct Combination Of Conductor Crimp Barrel And Tool
C. Connector
27.What Are The Thing 5 Ewis Does Not Include
√A.Elec Equip For Testing Procedures
B. Labels
C.Pressure Seals
28.Which Stand- Alone Gvi (Independent General Visual Control)
Definition Is Given As Down?
A. Visual Inspection From Inside Or Outside Of A Component Or Assembly
√B.For The Detection Of Damage, Malfunction, Or Disturbance, A Precise
Object, Detailed Control Of Assembly Or Assembly
C.To Detect Inadequate And Inappropriate Situations In A Certain Area
29.Static Bleed Off, Proper Operation Of The Circuit Is Function Of:
A.Shield Grounding
√B. Bonding
C. Shield Wiring
30.What Is A Frequent Cause Of Failure In Elec. System Bonding And
Grounding?
√A. Corrosion
B. Loose
C.Wear
31.Under Which Regulatory System Is Enhanced Oil Analysis Procedure
(Ezap) Explained?
A.Amc 20-22
B. Amc 20-23
√C. Amc 20-21
34. AWIS Refresher Training Should Be Conducted In A ……………
√A. Two Period Not Exceeding Two Year
B.A Period Not Exceeding Two Year
C. Some Periods Not Exceeding Two Years
35.Unprotected ESDS: Courses …………
A.Cat A Strophic In Basic Failure
√B. Degradation Of Performance
C. Changes In Basic Failures
36.What Are Substances Used To Make The Insulation Materials For New
Aircraft Designs?
√A. Teflon Kapton, PTFE
B.Kapton PVC- TEF Zel
C. Teflon Kapton
37.When Any Fuel Pumps Circuit Breaker Tripped………..
A. Do Not Operate Any Fuel Pumps
B.None
√C. Put Fuel Pump Switch To Off Position
38. Which Is The Source Of Contamination?
√A. Fuel
B. Anti- Icing Lips
39. Caution At ESPM Why Is Lara Compliant?
A. There Is A possibility Of Damage To The Chip In Case Of Warnings
B. If Warnings Are Not …, There Is Chance That The Equipment Will Be
Damages
C. Caution Is Likely To Be Harmed If The Warnings Are Not Followed.

You might also like