0% found this document useful (0 votes)
86 views2 pages

Conductivity Type Level Switch: Salient Features

This document describes a conductivity type level switch, which uses low AC voltage between sensing electrodes and a reference electrode to detect the level of conductive liquids. It is available in integral and non-integral versions. When liquid touches the electrodes, a current flows and operates a relay to provide a visual indication and contacts for further operations. Key features include corrosion resistance, easy installation, and fail-safe functionality. Specifications cover enclosure type, connections, materials, temperature and pressure ratings.

Uploaded by

Y Yubt
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
86 views2 pages

Conductivity Type Level Switch: Salient Features

This document describes a conductivity type level switch, which uses low AC voltage between sensing electrodes and a reference electrode to detect the level of conductive liquids. It is available in integral and non-integral versions. When liquid touches the electrodes, a current flows and operates a relay to provide a visual indication and contacts for further operations. Key features include corrosion resistance, easy installation, and fail-safe functionality. Specifications cover enclosure type, connections, materials, temperature and pressure ratings.

Uploaded by

Y Yubt
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

CONDUCTIVITY TYPE LEVEL SWITCH

Conductivity type Level Switch is simple, low cost, point Level controller
that is used in variety of application for detecting level of conductive
liquids. It is available in two versions – one is non-integral (remote) and
other is integral.

A low AC Voltage is connected via the control unit between the sensing
electrodes and reference electrodes (tank wall in case of metallic
tanks). As soon as the conductive material touches the electrodes, a low

AC current starts to flow which operates the relay in the control unit.

Probe unit consists of electrode assembly and probe head. Electrode


assembly consists of sensing electrodes (whose tip is at the point where
level detections are required) and a reference electrode (required for
non metallic tank). Control unit provides the visual indication for level Probe

and relay output whose potential free contacts are available for
subsequent operation.

The control unit houses sensing electronics consisting of power supply


and signal conditioning circuit, which provide a low AC voltage across
sensing electrodes and reference electrodes. Integral version does not
have a separate control unit and the controller electronics is provided in
the probe head.

Salient Features
Controller
o Uses proven level control techniques;
o Wide range of application including corrosive media;

o Simple to install;
o Fail safe features incorporated;
o Can be operated as independent level controller or differential
level controller;
Specifications
Enclosure : Cast Aluminum / Ms Fabricated / Fiber Glass / DMC etc.
Enclosure Protection : IP – 55 / IP – 66 / IP – 67.
Cable entry : ¾” ET, ½” NPT, etc.
Process connection : Flanged/Threaded as per BIS, BS, ANSI & other standard.
Probe type : Rigid up to 3 Meters and Flexible up to 10 Meters.
Electrode material : SS 304 / SS 304L / SS 316 / SS 316L / Titanium, etc.
Electrode insulation : PVC / PTFE / Rubber Lined, etc.
No. of preset level : Up to 4 (four) for non-integral and Up to 2 (two) for integral.
Sensitivity (max.) : 100 micro siemens
Output : DPDT for each alarm level, rated 5A, 230 VAC, resistive load.
Power supply : 110/230 ± 10% V AC, 50 Hz or 24V DC.
Indication : LED - Red for Alarm & Green for normal.
Mounting : Horizontal / Vertical.
Maximum Temperature : 200°C for non-integral and 60°C for integral Version
Maximum Pressure : 25 Kg/cm² for rigid probe unit and 20 Kg.cm² for Flexible probe unit.

Model Number of Conductivity Type Level Switch

Note: 1) Flexible probe are provided with a counter weight.


2) A transmitter card will be mounted inside probe head for non integral models having 3 or
more relays so that probe unit can be connected to remote unit using two wire.

Marketed By:

D. K. Instruments Pvt. Ltd.


An ISO 9001:2008 Certified Company
76/2, Selimpur Road, Dhakuria, Kolkata – 700 031.
Ph. No.: 91-33-2415 1310 / 2405 0944, Fax: 91-33-2415 2311.
E-mail: [email protected], Web Site: www.dkinstruments.com