HX-WCS HX-2.5GHz TDD Remote and EPM Training and Troubleshooting Guide - ...
HX-WCS HX-2.5GHz TDD Remote and EPM Training and Troubleshooting Guide - ...
Presenter Name
Presenter Title
Business Unit
Date
Information Security
.
Business Name Corning Restricted 3 .
.
System Overview
.
Business Name Corning Restricted 4 .
.
System Overview
.
Business Name Corning Restricted 5 .
.
System Overview
.
Business Name Corning Restricted 6 .
.
System Overview
DL path: BU Input level -20 dBm, Optical output level from BU 0÷-2 dBm, HX-WCS UNIT output level
(at each antenna port) 21-33dBm (130mW to 2W)
Optical Fiber Loss Compensation Atten : 8dB (Optic Fiber Loss 0~4dBo)
BU Gain Compensation Atten : 2dB
UL path: Optical output level from HX-WCS UNIT 2.5÷5 dBm, Output level from BU -10 dBm
Gain setting Range : 21dB ~ 41dB
.
Business Name Corning Restricted 7 .
.
System Overview
• HX-WCS Budget
DL path: OCH Input level -20 dBm, Optical output level from OCH 0÷-2 dBm, HX-2.5GHz TDD UNIT
output level (at each antenna port) 21-33dBm (130mW to 2W)
Optical Fiber Loss Compensation Atten : 12dB (Optic Fiber Loss 0~6dBo)
OCH Gain Compensation Atten : 2dB
UL path: Optical output level from HX-2.5GHz TDD UNIT 2.5÷5 dBm, Output level from OCH -10 dBm
Gain setting Range : 21dB ~ 41dB
.
Business Name Corning Restricted 9 .
.
System Overview
.
Business Name Corning Restricted 11 .
.
System Overview
.
Business Name Corning Restricted 12 .
.
System Overview
.
Business Name Corning Restricted 13 .
.
System Overview
.
Business Name Corning Restricted 14 .
.
System Overview
.
Business Name Corning Restricted 15 .
.
System Overview
.
Business Name Corning Restricted 16 .
.
System Overview
.
Business Name Corning Restricted 17 .
.
System Overview
.
Business Name Corning Restricted 19 .
.
System Overview
.
Business Name Corning Restricted 20 .
.
System Overview
.
Business Name Corning Restricted 21 .
.
System Overview
.
Business Name Corning Restricted 23 .
.
System Overview
.
Business Name Corning Restricted 24 .
.
System Overview
.
Business Name Corning Restricted 25 .
.
System Overview
4.3-10 Type duplexed wideband remote unit expansion port for interfacing to external RF In source
WB-RU (i.e. HX4 remote) so that additional services are combined with those of the HX and distributed
from the duplexed HX antenna port
DL Test CPL. Port SMA-Type female 50Ω connector (40 dB ± 2 dB) used for RF DL test
RS-232 D-Type 9 pin female console port used for connecting to engineering GUI
Ext. Alarms DB-9 female external alarm connector for external dry contact alarm connections
.
Business Name Corning Restricted 26 .
.
System Overview
.
Business Name Corning Restricted 27 .
.
System Overview
.
Business Name Corning Restricted 28 .
.
System Overview
.
Business Name Corning Restricted 29 .
.
System Overview
CPL. SMA-Type female 50Ω coupling port (-40 dB ± 1.0 dB) used for RF DL test (one per multiplexer)
WB RU N-Type duplexed wideband remote unit expansion port for interfacing to HX4 remote (one per
multiplexer) so that additional HX4 services are combined with those of the HX 2.5 GHz TDD and
distributed from its antenna port
WCS RU Mini DIN 4.3-10 Type duplexed port (one per multiplexer) for interfacing to HX WCS RF input so
that additional WCS service is combined with those of the HX 2.5 GHz TDD and distributed from its
antenna port
Ext. 1 / Ext. 2 N/A (Future option)
Ext. Alarms DB-9 female external alarm connector for external dry contact alarm connections; Supports up to
four external alarms (configurable via the Web GUI)
RS-232 D-Type 9 pin female console port used for connecting to engineering GUI
.
Business Name Corning Restricted 30 .
.
System Overview
.
Business Name Corning Restricted 31 .
.
System Overview
Optic Port SC APC fiber-optic pair connector; SM fiber; connection towards OCH
HX Module
.
Business Name Corning Restricted 32 .
.
GUI Review
.
Business Name Corning Restricted 33 .
.
GUI Review
.
Business Name Corning Restricted 34 .
.
GUI Review
Module Info Product revision hxnProductRevision Read Only alpha numerical, XX.YY Product revision
.
Business Name Corning Restricted 35 .
.
GUI Review
.
Business Name Corning Restricted 36 .
.
GUI Review
Adjustment result hxnAdjustmentResult Read Only Adjustment result - N/A, Fail, Success
Do Adjust hxnDoAdjust PB
DL\UL\Auto mode to test signal and be only for CMA useres ,TDD only, will
DL\UL test mode Read / Write able to ajust manualy for testing perfesess remain in a status for 4 hours and return
TDD only to Auto
.
Business Name Corning Restricted 37 .
.
GUI Review
.
Business Name Corning Restricted 38 .
.
GUI Review
Service Off hxnServiceOffSet Read Only checked / Unchecked via "alarm masking" major severity
Service Off hxnServiceOffClear Read Only checked / Unchecked via "alarm masking" Notify severity
DL Output power High hxnOutputPowerHighSet Read Only checked / Unchecked via "alarm masking" minor severity
DL Output power High hxnOutputPowerHighClear Read Only checked / Unchecked via "alarm masking" Notify severity
DL Output power Low hxnOutputPowerLowSet Read Only checked / Unchecked via "alarm masking" major severity
Service Alarms
DL Output power Low hxnOutputPowerLowClear Read Only checked / Unchecked via "alarm masking" Notify severity
VSWR Alarm hxnVSWRAlarmSet Read Only checked / Unchecked via "alarm masking" major severity
VSWR Alarm hxnVSWRAlarmClear Read Only checked / Unchecked via "alarm masking" Notify severity
RF AdjustmentFail hxnAdjustmentFailSet Read Only checked / Unchecked via "alarm masking" Minor severity
RF AdjustmentFail hxnAdjustmentFailClear Read Only checked / Unchecked via "alarm masking" Notify severity
DL Protection activation hxnProtectionActivatedSet Read Only checked / Unchecked via "alarm masking" major severity
DL Protection activation hxnProtectionActivatedClear Read Only checked / Unchecked via "alarm masking" Notify severity
.
Business Name Corning Restricted 39 .
.
GUI Review
Temperature protection hxnTemperatureProtectionSet Read Only checked / Unchecked via "alarm masking" major severity
Temperature protection hxnTemperatureProtectionClear Read Only checked / Unchecked via "alarm masking" Notify severity
Fans Minor hxnFansMinorFaultSet Read Only checked / Unchecked via "alarm masking" minor severity, for first fan alarm only
Fans Minor hxnFansMinorFaultClear Read Only checked / Unchecked via "alarm masking" minor severity, for first fan alarm only
Fans Major hxnFansMajorFaultSet Read Only checked / Unchecked via "alarm masking" major severity, For any other fan alarm
General Alarms major severity, For any other fan alarm
Fans Major hxnFansMajorFaultClear Read Only checked / Unchecked via "alarm masking" (same indicator in GUI but different
severity)
optical adjustment hxnOpticalAdjustSet Read Only checked / Unchecked via "alarm masking" minor Severity (not for WCS)
optical adjustment hxnOpticalAdjustClear Read Only checked / Unchecked via "alarm masking" Notify severity (not for WCS)
Door Open hxnDoorOpenAlarmSet Read Only checked / Unchecked via "alarm masking" minor severity
Door Open hxnDoorOpenAlarmClear Read Only checked / Unchecked via "alarm masking" Notify severity
Major Severity, ONLY FOR WCS
Remote Unit optical Link hxnRemoteUnitOpticalLinkSet Read Only checked / Unchecked via "alarm masking"
REMOTES
Notify severity, ONLY FOR WCS
Remote Unit optical Link hxnRemoteUnitOpticalLinkClear Read Only checked / Unchecked via "alarm masking"
REMOTES
Overall Status hxnOverallStatus Read Only
Change name to Alarm Masking
Alarm Masking hxnAlarmMask Read / Write Button
RH: change done
.
Business Name Corning Restricted 40 .
.
GUI Review
.
Business Name Corning Restricted 41 .
.
GUI Review
.
Business Name Corning Restricted 42 .
.
GUI Review
.
Business Name Corning Restricted 43 .
.
GUI Review
.
Business Name Corning Restricted 44 .
.
GUI Review
Module Info Product revision hxnProductRevision Read Only alpha numerical, XX.YY Product revision
.
Business Name Corning Restricted 45 .
.
GUI Review
.
Business Name Corning Restricted 46 .
.
GUI Review
Adjustment result hxnAdjustmentResult Read Only Adjustment result - N/A, Fail, Success
Do Adjust hxnDoAdjust PB
RF Parameters DL DCA Range (total, available for user to set
DL Attenuation hxnDLAttenuation Read / Write
from)
DL Output power hxnDLOutputPower Read Only Current output power of the remote
.
Business Name Corning Restricted 47 .
.
GUI Review
.
Business Name Corning Restricted 48 .
.
GUI Review
Service Off hxnServiceOffSet Read Only checked / Unchecked via "alarm masking" major severity
Service Off hxnServiceOffClear Read Only checked / Unchecked via "alarm masking" Notify severity
DL Output power High hxnOutputPowerHighSet Read Only checked / Unchecked via "alarm masking" minor severity
DL Output power High hxnOutputPowerHighClear Read Only checked / Unchecked via "alarm masking" Notify severity
DL Output power Low hxnOutputPowerLowSet Read Only checked / Unchecked via "alarm masking" major severity
Service Alarms
DL Output power Low hxnOutputPowerLowClear Read Only checked / Unchecked via "alarm masking" Notify severity
VSWR Alarm hxnVSWRAlarmSet Read Only checked / Unchecked via "alarm masking" major severity
VSWR Alarm hxnVSWRAlarmClear Read Only checked / Unchecked via "alarm masking" Notify severity
RF AdjustmentFail hxnAdjustmentFailSet Read Only checked / Unchecked via "alarm masking" Minor severity
RF AdjustmentFail hxnAdjustmentFailClear Read Only checked / Unchecked via "alarm masking" Notify severity
DL Protection activation hxnProtectionActivatedSet Read Only checked / Unchecked via "alarm masking" major severity
DL Protection activation hxnProtectionActivatedClear Read Only checked / Unchecked via "alarm masking" Notify severity
.
Business Name Corning Restricted 49 .
.
GUI Review
Temperature protection hxnTemperatureProtectionSet Read Only checked / Unchecked via "alarm masking" major severity
Temperature protection hxnTemperatureProtectionClear Read Only checked / Unchecked via "alarm masking" Notify severity
Fans Minor hxnFansMinorFaultSet Read Only checked / Unchecked via "alarm masking" minor severity, for first fan alarm only
Fans Minor hxnFansMinorFaultClear Read Only checked / Unchecked via "alarm masking" minor severity, for first fan alarm only
Fans Major hxnFansMajorFaultSet Read Only checked / Unchecked via "alarm masking" major severity, For any other fan alarm
General Alarms major severity, For any other fan alarm
Fans Major hxnFansMajorFaultClear Read Only checked / Unchecked via "alarm masking" (same indicator in GUI but different
severity)
optical adjustment hxnOpticalAdjustSet Read Only checked / Unchecked via "alarm masking" minor Severity (not for WCS)
optical adjustment hxnOpticalAdjustClear Read Only checked / Unchecked via "alarm masking" Notify severity (not for WCS)
Door Open hxnDoorOpenAlarmSet Read Only checked / Unchecked via "alarm masking" minor severity
Door Open hxnDoorOpenAlarmClear Read Only checked / Unchecked via "alarm masking" Notify severity
Major Severity, ONLY FOR WCS
Remote Unit optical Link hxnRemoteUnitOpticalLinkSet Read Only checked / Unchecked via "alarm masking"
REMOTES
Notify severity, ONLY FOR WCS
Remote Unit optical Link hxnRemoteUnitOpticalLinkClear Read Only checked / Unchecked via "alarm masking"
REMOTES
Overall Status hxnOverallStatus Read Only
Change name to Alarm Masking
Alarm Masking hxnAlarmMask Read / Write Button
RH: change done
.
Business Name Corning Restricted 50 .
.
GUI Review
.
Business Name Corning Restricted 51 .
.
GUI Review
.
Business Name Corning Restricted 52 .
.
GUI Review
.
Business Name Corning Restricted 53 .
.
GUI Review
1 Channel frequency hxnTdd1ChannelFrequncy Read / Write L01-L39 or 2496.0-2690.0 TDD only, otheres NA
2 Channel frequency hxnTdd2ChannelFrequncy Read / Write L01-L39 or 2496.0-2690.1 TDD only, otheres NA
3 Channel frequency hxnTdd3ChannelFrequncy Read / Write L01-L39 or 2496.0-2690.2 TDD only, otheres NA
4 Channel frequency hxnTdd4ChannelFrequncy Read / Write L01-L39 or 2496.0-2690.3 TDD only, otheres NA
TDD parameters 5 Channel frequency hxnTdd5ChannelFrequncy Read / Write L01-L39 or 2496.0-2690.4 TDD only, otheres NA
6 Channel frequency hxnTdd6ChannelFrequncy Read / Write L01-L39 or 2496.0-2690.5 TDD only, otheres NA
UL\DL allocation mode hxnTddUlDlAllocationMode Read / Write 0-6 TDD only, otheres NA
Sub Frame Allocation hxnTddSubFrameAllocationMode Read / Write 0-9 (Normal), 0-7 (Extended) TDD only, otheres NA
Extended Sub Frame hxnTddSubFrameExtendedMode Read / Write 0-Normal 1-Extended TDD only, otheres NA
.
Business Name Corning Restricted 54 .
.
GUI Review
.
Business Name Corning Restricted 55 .
.
GUI Review
3. Operating GUI
A software that can monitor and control HX-WCS & HX-2.5GHz TDD using PC and serial
communication.
Serial Communication Cable: General D-Sub 9-pin Cable. (Not included)
.
Business Name Corning Restricted 56 .
.
GUI Review
.
Business Name Corning Restricted 57 .
.
GUI Review
.
Business Name Corning Restricted 58 .
.
GUI Review
.
Business Name Corning Restricted 59 .
.
GUI Review
.
Business Name Corning Restricted 62 .
.
GUI Review
HE Rx Link Status
S,C
S
1
1
6
7
Uncheck : Mask, Check : Unmask
The number is PDI value
OFF : 0-35, Low : 36-100, Normal : 101-255
S : Status
Alarm
Optic
WCS Optic
HE Fiber Mode
HE Optic Rx Link Level
S
S
1
2
8
9
Non WDM / SMF / SISO or MIMO
dBm/Raw C : Control
Information HE Optic Tx Power S 1 11 unit : 0.5dBo
HPA
HE Optic Loss S 1 12 unit : 0.5dB
HE Optic Adjust ATT S 1 13 unit : 0.5dB
RU Optic Adjust ATT S 1 14 unit : 0.5dB
The number is PDI value
RU Rx Link Status S 1 15
OFF : 0-35, Low : 36-100, Normal : 101-255
Remote Optic
RU Optic Rx Link Level S 2 16 dBm/Raw
Information
RU Optic Tx Power S 1 18 unit : 0.5dBo
RU Optic Loss S 1 19 unit : 0.5dB
Return Loss S 2 20
VSWR S 2 22
Return Loss Threshold S,C 2 24
HPA VSWR Threshold S,C 2 26
Information
VSWR Alarm Check Mode S,C 1 28 Return Loss
Unknown, High Temperature, VSWR, Over Power, DC Fail, User,
HPA Off Reason S 1 29
Over Power, Device Fail
Etc. Alarm S 1 30 Optic Adjust, Module Insert, Optic Module Link, HPA Module Link
Uncheck : Mask, Check : Unmask
External Alarm & Mask S 2 31
Normal : Green, Alarm : Red
Etc. Status Severity : Notification, Minor, Major
Alarm External Alarm Severity, Trigger Level S,C 2 33
Trigger Level : N.C, N.O
Optic Reset C 1
HPA Reset C 1
Optic Adjust C 1 Optic Adjust Value
.
Business Name Corning Restricted 63 .
.
GUI Review
.
Business Name Corning Restricted 64 .
.
GUI Review
DL PWR
DL Output Power (RMS)
DL Output Power (Peak)
S
S
2
2
3
5
"LOW" : < -2dBm
"LOW" : < -2dBm
S : Status
Information
HPA On/Off
Output Power Mode
S,C
S,C
1
1
7
8
ON / OFF
Average, Peak
C : Control
DL Operation DCA S 1 9 unit : 0.5dB
DL Manual DCA S,C 1 10 unit : 0.5dB
DL Att
DL Factory DCA S,C 1 11 unit : 0.5dB
Information
DL Limiter DCA S 1 12 unit : 0.5dB
DL Restore Factory C 1
.
Business Name Corning Restricted 66 .
.
GUI Review
.
Business Name Corning Restricted 67 .
.
GUI Review
.
Business Name Corning Restricted 68 .
.
GUI Review
.
Business Name Corning Restricted 69 .
.
GUI Review
.
Business Name Corning Restricted 70 .
.
GUI Review
HE Rx Link Status
S,C
S
1
1
6
7
Uncheck : Mask, Check : Unmask
The number is PDI value S : Status
OFF : 0-35, Low : 36-100, Normal : 101-255
Etc. Alarm S 1 30 Optic Adjust, Module Insert, Optic Module Link, HPA Module Link
Uncheck : Mask, Check : Unmask
External Alarm & Mask S 2 31
Normal : Green, Alarm : Red
Etc. Status Severity : Notification, Minor, Major
Alarm External Alarm Severity, Trigger Level S,C 2 33
Trigger Level : N.C, N.O
Optic Reset C 1
HPA Reset C 1
Optic Adjust C 1 Optic Adjust Value
.
Business Name Corning Restricted 71 .
.
GUI Review
.
Business Name Corning Restricted 72 .
.
GUI Review
DL PWR
Information
DL Output Power (RMS)
DL Output Power (Peak)
S
S
2
2
3
5
"LOW" : < -5dBm
"LOW" : < -5dBm S : Status
HPA On/Off S,C 1 7 ON /OFF
Output Power Mode
DL Operation DCA
S,C
S
1
1
8
9
Average, Peak
unit : 0.5dB
C : Control
DL Manual DCA S,C 1 10 unit : 0.5dB
DL Att
DL Factory DCA S,C 1 11 unit : 0.5dB
Information
DL Limiter DCA S 1 12 unit : 0.5dB
DL Restore Factory C 1
DL ALC DL Limiter On/Off S,C 1 13 ON / OFF
Information DL Limiter Status S 1 14 Disable / Enable / Active(Limiter is running)
DL Max Output Power S,C 1 15 range : +19 - +34dBm
DL Th. DL Output High Threshold S,C 1 16 Max Output Power + 2
Information DL Output Low Threshold S,C 1 17 Max Output Power - 20
DL Output Protection Threshold S,C 1 18 Max Output Power + 3
UL PWR UL Input Power (RMS) S 2 19 "LOW" : < -55dBm
Information UL Output Power (RMS) S 2 21 "LOW" : < -40dBm
UL Operation DCA S 1 23 unit : 0.5dB
UL Manual DCA S,C 1 24 unit : 0.5dB
UL Att UL Factory DCA S,C 1 25 unit : 0.5dB
Information UL Limiter DCA S 1 26 unit : 0.5dB
DL Path UL Gain Set S,C 1 27 High : 41dB, Normal : 31dB, Low : 21dB
UL Path
UL Restore Factory C 1
UL ALC UL Limiter On/Off S,C 1 28 ON / OFF
Information UL Limiter Status S 1 29 Disable / Enable / Active(Limiter is running)
DL RF Adjustment DCA S 1 30 unit : 0.5dB
Adjustment DATE S 3 31 Adjustment Success Date
RF Adj. Adjustment Time S 3 34 Adjustment Success Time
Information DL RF Adjustment Result S 1 37 Success, Fail(Low power),Fail(Over power),In Progress
Start adjustment
DL Do Adjustment C 7
(include YY/MM/DD hh:mm:ss, DL Output Max Power)
Ext. DL Gain S,C 1 38
Gain Ext. UL Gain S,C 1 39
Information DL Extension On/Off S,C 1 40 ON / OFF
UL Extension On/Off S,C 1 41 ON / OFF
T Sync Frequency Set 12 42 val *0.1 (100kHz)
Freq. Info. Operation Frequency 2 54 val *0.1 (100kHz)
Switch Mode 1 56 Auto, DL Only, UL Only, OFF
UL/DL Config 1 57 Config Num #0 ~ #6
SSF Config 1 58 if normal CP : #0 ~ #9, if extended CP : #0 ~ #7
T Sync CP Type 1 59 Normal CP(default), Extended CP
Information
DL/UL Gap 2 60
Sync Operation Mode S,C 1 62 PSS Sync Signal(default)
PSS Threshold S,C 2 63 default : 0x50
.
Business Name Corning Restricted 73 .
.
GUI Review
• Single firmware can be downloaded through SC-450 Web GUI to RCU/OPTIC/HPA at a time.
(Except, SISO/MIMO is classified)
• But, downloading through Eng. GUI is separately done for each module(RCU/OPTIC/HPA).
(Download the update-required module only)
.
Business Name Corning Restricted 74 .
.
GUI Review
.
Business Name Corning Restricted 75 .
.
GUI Review
Click
Download
.
Business Name Corning Restricted 77 .
.
GUI Review
RCU version
information change check
Swap RCU Firmware.
.
Business Name Corning Restricted 78 .
.
GUI Review
System Reset
.
Business Name Corning Restricted 79 .
.
Typical Field Issues
Initial Value
No Alarm Detail Corrective Actions
WCS 2.5-TDD
1) Alarm on: Service alarm on due to shutdown
- Check 4 alarms(OverTemp Protection, DL Protection
algorithm (OverTemp Protection,
1 Service and VSWR, TDD Sync) and follow its corrective actions
DL Protection, VSWR, TDD Sync)
2) Alarm off: shutdown condition cleared
1) Alarm on : DL Output Power > Max output
power+ 2dB - After checking output, adjust the output(control Manual Max output power
2 DL Output High
2) Alarm off : DL Output Power < Max output Atten or redo RF Adjustment) = 33dBm
power (Hysteresis 2dB)
- Check connection of Optic Cable
1) Alarm on : RF Power < Max output power-20dB Max output power
: (GUI) Optic Rx level, Optic Link Alarm etc.
3 DL Output Low 2) Alarm off : RF Power > Max output power-18dB = 33dBm
- Check RF Input Level
(Hysteresis 2dB)
- Check attenuator settings (Adjust Att, Manual DCA)
- Connect output terminal (ANT) High Power Term and
1) Alarm on : VSWR > VALUE (VSWR Threshold) check if alarm is off
VSWR threshold =
4 VSWR 2) Alarm off : Measured VSWR < VALUE (VSWR - Check antenna connection and VSWR of the antenna
2:1(RL: 8.5dB)
Threshold) - Check for foreign substance on output terminal
connector and connection cable
- Check Optic Cable connection: Check if Fiber Optical
1) Alarm on : DL RF Adjustment = Fail loss is within standard range of the device.
a) Despite ATT is operating, Over Power or Under → Loss: 4dBo(HX-WCS), 6dBo(HX-2.5GHz TDD).
RF Adjustment power - Check RF connection : While performing adjustment,
5
Fail b) When failed, ATT restores default or previous check if calibration signal of RU(GUI: DL Input Power) is
value. detected on optimal level.
2) Alarm off : DL RF Adjustment = Success / NA → Reference level : -48.5dBm(HX-WCS), -40dBm
(HX2.5GHz TDD) @ 0dBo
.
Business Name Corning Restricted 80 .
.
Typical Field Issues
Initial Value
No Alarm Detail Corrective Actions
WCS 2.5-TDD
1) Alarm on: RF Power > Max output power + 3dB
- Occurs when: RF Power > DL Protection Threshold.
- Check if Max output Power and DL Limiter is
2) Alarm off Max output power
6 DL Protection working correctly.
a) RF Power < Max output power - 3dB = 33dBm
- Check RF Input Level.
b) Recheck alarm after alarm is turned off if user
control is ON
- Check RF Input Level.
- Check TDD Parameter.
→ Check if DL/UL Configuration information is
TDD Sync 1) Alarm on : TDD Sync failed
7 identical to base station and whether SSF is
(HX-2.5GHz TDD Only) 2) Alarm off : TDD Sync success
being transmitted or not.
→ Check if frequency information is similar to
base station signal.
1) Alarm on : Limiter function on,
- Check Output Max Power and RF input/output Max output power
8 DL Limiter DL Output Power > Max output power
level. = 33dBm
2) Alarm off : DL Output Power < Max output power
.
Business Name Corning Restricted 81 .
.
Typical Field Issues
Initial Value
No Alarm Detail Corrective Actions
WCS 2.5-TDD
- Check optic cable connection:
1) Alarm on: PD Detector value is lower than
Check if Fiber Optical loss is within device’s standard
standard
range.
10 (HE) Optical link → HX-WCS(-5dBm), HX-2.5GHz TDD(-7dBm)
→ Loss: 4dBo(HX-WCS), 6dBo(HX-2.5GHz TDD).
2) Alarm off : PD Detector value is within standard
- Check the cleanliness of optic cable and module
range
- Check the bending/sheath of optic cable
1) Alarm on: Temperature > OverTemp Alarm
Threshold
2) Alarm off : Temperature < OverTemp Alarm - Check OverTemp alarm threshold value. OverTemp Alarm
11 Over Temperature
Threshold – 5 degrees (Hysteresis 5℃) - Check FAN alarm and operating status. Threshold = 75℃
3) Temperature = Base on temperature indicated on
GUI’s Main System
1) Alarm on : Temperature > OverTemp Protection
Threshold
OverTemp
Over Temperature 2) Alarm off : Temperature < OverTemp Protection - Check OverTemp Protection threshold value.
12 Protection
Protection Threshold – 15 degrees (Hysteresis 15℃) - Check FAN alarm and operating status.
Threshold = 85℃
3) Temperature = Base on temperature indicated on
GUI’s Main System
- Visually inspect the condition of relevant FAN and
1) Alarm on : FAN stop working.(5 seconds or more)
FAN-Tray (foreign substance, outside interference, etc.)
a) Minor alarm : First FAN warning (Yellow)
- Check FAN Cable connection and FAN input power
b) Major alarm : More than one FAN warning (Red)
13 FAN Alarm - Connect the power switch of problematic FAN to
2) Alarm off : Alarm turns off if FAN works normally
normal working FAN port and check if it’s the FAN itself
3) User control On/off function implemented and
that’s not working.
status saved.
- Exchange FAN
.
Business Name Corning Restricted 82 .
.
Typical Field Issues
Initial Value
No Alarm Detail Corrective Actions
WCS 2.5-TDD
1) Alarm on : When PD Detector value is lower than
- Check the connection of optic cable.
standard value
- Check the LD Level of 2nd hop remote (ex.HX4)
RU Optical link → HX-WCS(-5dBm)
14 connected to RU.
(HX-WCS Only) 2) Alarm off : PD Detector value is within standard
- Check the cleanliness of optic cable and module
range
- Check the bending/sheath of optic cable
Exchange the HX-Module if alarm is still raised after corrective actions are performed.
Exchange the Chassis if alarms is still raised after HX-Module is exchanged.
.
Business Name Corning Restricted 83 .
.
Default Value GUI – WCS(SYSTEM Tap)
.
Business Name Corning Restricted 84 .
.
Default Value GUI - WCS(ALARM/OPTIC/HPA Tap)
.
Business Name Corning Restricted 85 .
.
Default Value GUI - WCS(DL Path / UL Path Tap)
.
Business Name Corning Restricted 86 .
.
Default Value GUI – 2.5GHz TDD(SYSTEM Tap)
.
Business Name Corning Restricted 87 .
.
Default Value GUI – 2.5GHz TDD(ALARM/OPTIC/HPA Tap)
.
Business Name Corning Restricted 88 .
.
Default Value GUI – 2.5GHz TDD(DL Path / UL Path Tap)
.
Business Name Corning Restricted 89 .
.
Power Connection
.
Business Name Corning Restricted 91 .
.
Power Connection
– Maximum input Power Consumption of Dinkle Connector of Input power terminal of PSU by Pair is
62W.
– When Max Output power, WCS is recommended to connect minimum of 2 pairs, and 2.5GHz-TDD
is recommended to connect minimum of 3 pairs in consideration of power consumption.
.
Business Name Corning Restricted 92 .
.
Power Connection
.
Business Name Corning Restricted 93 .
.
RF Adjustment – SC-450 Web GUI
• RF Adjustment by CW signal – 2.5GHz TDD
②
①
④ ⑤
③
.
Business Name Corning Restricted 94 .
.
RF Adjustment – SC-450 Web GUI
• RF Adjustment by CW signal – 2.5GHz TDD
②
①
④ ⑤
③
②
①
④ ⑤
③
6. In order to check if RF Adjustment is normally performed, set ‘⑤Switch Mode’ as “Downlink” and
check ‘DL Output Power’. Then, set ‘⑤Switch Mode’ back to “AUTO”.
※ In terms of BTSC, some functions as like frequency and attenuator setting and so on are limited.
.
Business Name Corning Restricted 96 .
.
RF Adjustment – HX-2.5GHz TDD GUI
• RF Adjustment by CW signal – 2.5GHz TDD
⑥
④
③
.
Business Name Corning Restricted 97 .
.
RF Adjustment – HX-2.5GHz TDD GUI
• RF Adjustment by CW signal – 2.5GHz TDD
1. Check if ‘① DL Input Power Level’ of GUI is in the normal range of -52dBm to -40dBm.
2. Set the value in ‘②DL Output Max Power’.(19dBm ~ 34dBm)
3. Click ‘③DL Do Adjust’ and it automatically carries out RF Adjustment. (In case of HX-2.5GHz TDD,
when clicked ‘DL Do Adjust’ it is set to carry out ‘DL only’ and ‘HPA On’ by internal algorithm.)
4. After completion of RF Adjustment, check if ‘④Status’ is “Success”. If “Success” then, ‘Date and
Time’ will be updated to the latest time of “Success”.
5. Then ⑤Switch Mode will get back to “Auto”. Since input signal is CW signal, TDD Sync alarm
would occur making HPA OFF. (In case that input signal is normal TDD signal, output power is
being kept after RF Adjustment.)
6. In order to check if RF Adjustment is normally performed, set ‘④ Switch Mode’ as “DL Only” and
‘⑥HPA On/Off’ as “On” and check ‘DL Output Power’. Then, set ‘④Switch Mode’ back to “AUTO”.
.
Business Name Corning Restricted 98 .
.
LTE TDD UL/DL Configuration
Uplink-Downlink Allocations
0
Module Replacement
• Step by step instructions on module replacements
1. Fan replacement
1) Open cabinet door, if not already open, to access the fan interface cover at the
door.
2) Open the fan interface cover in the middle of door.
3) Disconnect the cable of the fan being replaced and separate it from the door.
4) Attach new FAN(including finger guide) to the Door and connect the cable.
5) Check if FAN is working properly.
FAN 1
FAN 2
FAN 3
FAN 4
.
Business Name Corning Restricted 102 .
.
Module Replacement
.
Business Name Corning Restricted 103 .
.
Connection Guidance on EPM with 2K’s
.
Business Name Corning Restricted 104 .
.
Connection Guidance on EPM with 2K’s
Marketing Label
Label (Position)
.
Business Name Corning Restricted 105 .
.
Connection Guidance on EPM with 2K’s
Front HIGH I/O One Mini DIN 4.3-10 high-band input port interfaces to HX-WCS
.
Business Name Corning Restricted 106 .
.
Connection Guidance on EPM with 2K’s
.
Business Name Corning Restricted 107 .
.
Connection Guidance on EPM with 2K’s
.
Business Name Corning Restricted 109 .
.
Connection Guidance on EPM with 2K’s
.
Business Name Corning Restricted 110 .
.
Connection Guidance on EPM with 2K’s
.
Business Name Corning Restricted 111 .
.