Commands - For - NOKIA DX 200 O&M
Commands - For - NOKIA DX 200 O&M
TypeUnitOrDepartmentHere
TypeYourNameHere TypeDateHere
MSS/MGW Commands
To check alarms
------------------------------------------------------------------------------------------------------------------------------------
PCM Status for MSS/MGW
ZYEI:ET,257; --- To see frame alignment mode of PCM. For Inter MSC and POI it should be DBLF
and for ATER it should be CRC4.
If you find commnds are blocked then you can unblock by using the following command :-
MSS
ZUSI:SIGU; ---- All SIGUs should be in WO-EX condition except one in SP-EX.
DOCUMENTTYPE 2 (12)
TypeUnitOrDepartmentHere
TypeYourNameHere TypeDateHere
MGW
-----------------------------------------------------------------------------------------------------------------------------------
Fallbeck
ZIPS:"OMU",WDU-S,/FB160309,,:"OMU",FDU-0,,,:NAME=FB160309,DIR=INC,ISD=Y,:DCM=NEW,:;
To start fallback in MOD form HDD
ZUSI:<UNIT NAME>; ----- To see specific unit state in MSS and MGW
----------------------------------------------------------------------------------------------------------------------------------------
To see subscribers in VLR in MSS
TypeUnitOrDepartmentHere
TypeYourNameHere TypeDateHere
ZNRI:NA1,D’1234; --- To see signaling route set date where 1234 is the SPC in NA1 where D
means value in Decimal
ZNRI:NA0,D’1234; ---- To see signaling route set date where 1234 is the SPC in NA0 where D
means value in Decimal
ZNCC:1:124-16,64,1,1:CCSU,2:0:;
Clock SYNCHRONIZATION
ZDRI; ----------- To see external clock synchronization STATE should be connected in MSS
DOCUMENTTYPE 4 (12)
TypeUnitOrDepartmentHere
TypeYourNameHere TypeDateHere
ZUSI:CLS; --- To see internal clock one should bw WO-EX and another should be in SP-EX in
MSS
ZUSI:TBU; -- To see internal clock one should bw WO-EX and another should be in SP-EX in
MGW
-------------------------------------------------------------------------------------------------------------------------------------------
GT Analysis and Result Record in MSS
RESULT ANALYSIS
SS7 GTI TT NP NAI DIGITS RECORD TYPE
DOCUMENTTYPE 5 (12)
TypeUnitOrDepartmentHere
TypeYourNameHere TypeDateHere
To create Result Record we have to create Signalling Route with MML Command as below:-
ZNRC:NA1,D'1234,TEST,0,A,N:NA1,D'1234,TEST,7::::;
ZNVA:NA1,D'1234:NA1,D'1234:;
ZNVC:NA1,D'1234:NA1,D'1234:ACT;
ZNFD:NA1,D'1234,0:6,MAPH,0,:7,MAPV,0,:8,MAPM,0,:92,CAP,0,::;
ZNGC:NA1,D'1234:ACT;
ZNHC:NA1,D'1234:6:ACT;
ZNHC:NA1,D'1234:7:ACT;
ZNHC:NA1,D'1234:8:ACT;
ZNHC:NA1,D'1234:92:ACT;
For example
ZNAI:RES=6;
RESULT LS SP ENTITY LS
RECORD STA IND NET SP CODE H/D NAME RI STATE PR WGHT
------ --- --- --- ------------------ ----- --- ------ -- ----
00006 ACT NO NA1 13C4/05060 HLR01 SSN AV-EX - -
TypeUnitOrDepartmentHere
TypeYourNameHere TypeDateHere
ZNRI:NA1,D’5060;
CGR Commands
If you want to know a PCM is connected to which CGR then give the below mentioned
command:-
To change the state of the circuits in a CGR first give the below mentioned command
ZRCI:SEA=3:CGR=404:PRINT=4;
Kindly note down the PCM numbers and then the below command
ZRCI:SEA=3:CGR=404:PRINT=2;
CIRCUIT GROUP(S)
DOCUMENTTYPE 7 (12)
TypeUnitOrDepartmentHere
TypeYourNameHere TypeDateHere
FQDN :-
TRES1 : - TRES2 : -
DR1A : - DR2A : - ART1A : - ART2A : - ACTA : NO ACTION
DR1B : - DR2B : - ART1B : - ART2B : - ACTB : NO ACTION
DR1C : - DR2C : - ART1C : - ART2C : - ACTC : NO ACTION
COMMAND EXECUTED
Then copy the VMGW name (MSS01MGW0103) and then give the below command in MSS only
ZRCC:TYPE=ECCS,CGR=329,NCGR=BSC34SUR:DIR=OUT,NET=NA1,SPC=D'7034,LSI=AIF02,
UPART=5:MGW=ASMGW202:; --- To create CGR 329, with Name- BSC34SUR, SPC-7034, and
VMGW- ASMGW202
ZRRC:EXT:ROU=329,OUTR=OMCG0,NCCP=MAS,STP=1,TON=UNK,NCGR=BSC34SUR; --- To
create Traffic ROUTE in MSS only
TypeUnitOrDepartmentHere
TypeYourNameHere TypeDateHere
-------------------------------------------------------------------------------------------------------------------------------------------
IMSI Analysis for Inroaming in MSS
ZCFC:IMSI= 72431,IMSIINDIC=2,PLMN=PCS_BRAZIL,TOA=GT,:NP=E214,TON=INT,SRD=1,NRD=5,
SAD=1,DIA=55031,:; --- To create IMSI analysis
ZMXP:NAME= PCS_BRAZIL; --- To see PLMN parameters and check the Supported CAMEL
Phaze
From the IMSI analysis o/p check the GT analysis properly with command ZNBI:::55031;
Then give command ZQNS; - to see in which VTP you have logged in. This command shows the
command you fired last.
< ZQNS;
COMMAND EXECUTED
From above o/p the logged VTP would be VTP-15 , because in its right side it is showing QN
command which you fired last.
TypeUnitOrDepartmentHere
TypeYourNameHere TypeDateHere
PAGE 1
LOG LOG SPARE PHYSICAL OBJ SYSTEM UNIT DEVICE/
FILE FILE FILE FILE IND NAME NAME LOGICAL
NBR NAME & CLASS MODE NAME FILE
COMMAND EXECUTED
Please note! In device list WDU-SB should be always connected to OMU. At a time max 4 device
can be connected one is WDU-SB of OMU and three are different VTP or LPT.
If you find that 4 devices are already connected and you want to connect another device then you
have to give the followind command:-
ZIIS::GSMME1PR:IND=3:DEV=VTP-15;
In this case IND=3 position VTP would be disconnected and new VTP would be added.
You can also give IND=2 or IND=4 according to the situation. Please do not disconnect the WDU-
SB from OMU.
We can also take trace using the below mentioned command at the time of call test
ZMCJ:IMSI=<IMSI NUMBER>::TYPE=D;
DIAGNOSTIC in MSS/MGW
TypeUnitOrDepartmentHere
TypeYourNameHere TypeDateHere
If we want to switchover the state of an unit we have to use the procedures as below:-
TOTAL OF 2 UNITS
COMMAND EXECUTED
Now if we want to change the state of OMU to WO-EX from SP-EX then we have to give the
following command:-
TOTAL OF 2 UNITS
COMMAND EXECUTED
For trunk to trunk call e.g POI and Inter MSC call test we have to take a B party test number first.
Make the A party number in TP in HLR (from where you initiate the calls) with command
DOCUMENTTYPE 11 (12)
TypeUnitOrDepartmentHere
TypeYourNameHere TypeDateHere
ZMIM:IMSI=<IMSI NUMBER>:CAT=TP;
ZCEC:MGW=MSS01MGW0103,TERMID=10274-1&&-31,:TE;
Now do test call and check the circuit with command ZMCJ:IMSI=<IMSI NUMBER>;
In this case we can do test calls for ATER where A party has to initiate a call provided A party
would be under the same BSC for which call test is being done.
Make the A party number in TP in HLR (from where you initiate the calls) with command
ZMIM:IMSI=<IMSI NUMBER>:CAT=TP;
ZCEC:MGW=MSS01MGW0103,TERMID=10274-1&&-31,:TE;
Now do test call and check the circuit with command ZMCJ:IMSI=<IMSI NUMBER>;
In this case we can do test calls for ATER where B party has to initiate a call provided B party
would be under the same BSC for which call test is being done.
ZYCM:4:INROUT=Y,CONT=N,:
TypeUnitOrDepartmentHere
TypeYourNameHere TypeDateHere
Make the B party number in TP in HLR (from where you initiate the calls) with command
ZMIM:IMSI=<IMSI NUMBER>:CAT=TP;
ZCEC:MGW=MSS01MGW0103,TERMID=10274-1&&-31,:TE;
Now do test call and check the circuit with command ZMCJ:IMSI=<IMSI NUMBER>;
ZTMI:<NAME OF MEASUREMENT>;
If we create a new CGR then we have to add the CGR in object lis for measurement
The commands are as follows:-