0% found this document useful (0 votes)
203 views

RTD TH13, TH14 and TH15: Technical Information

manual de medidor de temperatura

Uploaded by

David Mireles
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
203 views

RTD TH13, TH14 and TH15: Technical Information

manual de medidor de temperatura

Uploaded by

David Mireles
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 24

Technical Information

RTD TH13, TH14 and TH15


RTD assemblies in Thermowells with spring loaded insert and
enclosure for process industry

Areas of application
The TH13, TH14 and TH15 temperature sensors are RTD
assemblies installed in Thermowells and designed for use in
all types of process industries, including harsh environments,
due to their rugged design.
The sensor is made up of a measurement probe with an
insulated RTD element, sheath and a thermowell made of
bar-stock material.
The sensor assemblies can be used in process industries such
as:
• Chemicals
• Petrochemical
• Power plants
• Refineries
• Offshore Platforms
Head transmitters
Instead of directly wiring your temperature sensors to your
control system, use transmitters to reduce wiring and
maintenance costs while increasing measurement accuracy.
Field transmitters
Temperature field transmitters with HART® or
FOUNDATION Fieldbus™ protocol for highest reliability in
harsh industrial environments. Blue backlit display with large
measured value, bargraph and fault condition indication for
ease of reading.
Your benefits
• One source shopping for temperature measurement
solutions. World class transmitter with integrated sensor
offering for heavy process industry applications.
• Remove and install straight out of the box!
• Improved galvanic isolation on most devices (2 kV)
• Simplified model structure: Competitively priced, offers
great value. Easy to order and reorder. A single model
number includes sensor, thermowell and transmitter
assembly for a complete point solution
• All iTEMP® transmitters provide long term
stability ≤ 0.05 % per year

TI110R/24/ae
TH13, TH14, TH15

Function and system design


Measuring principle The RTD (Resistance Temperature Detector) element consists of an electrical resistance with a value of 100 Ω
at 0 °C (called Pt100, in compliance with IEC 60751), which increases at higher temperatures according to a
coefficient characteristic of resistor material (platinum). In industrial thermometers that comply with the
IEC 60751 standard, the value of this coefficient is α = 0.00385 °C-1, calculated between 0 and 100 °C
(32 and 212 °F).

Measuring system

Example of an application of the temperature assemblies


Water - heat Differential
Calculation of heat quantity which is emitted or absorbed by a water flow in a heating or cooling system. The quantity of
heat is calculated from the process variable for ∆p flow (Q) and the differential from the feed and return temperature
(T2 - T1). Bidirectional energy calculations, such as the calculating systems with changing flow direction (charging/
discharging the heat accumulator) are also possible.

Energy manager RMS621


Energy conservation and cost expenditures are significant issues in today's industry. Accurate flow monitoring
and calculation is the basis for thorough analysis and billing of energy. This data can serve as a basis to maximize
savings potential and help in controlling operational costs on a daily basis. Endress+Hauser's energy managers
provide accurate and reliable calculations for the monitoring and control of energy consumption (both
produced and consumed) according to international standards, e.g. IAPWS-IF 97, AGA8, ISO 5167 etc. For
RMS621 details see Technical Information.
iTEMP® TMT162 Temperature Field Transmitter
Aluminum or stainless steel dual compartment explosion - proof enclosure and compact, fully potted
electronics provide the ultimate protection in harshest environments. TMT162 prevents costly plant
shutdowns by detecting corrosion on RTDs or thermocouples before it corrupts the measured value.
Endress+Hauser's Field Temperature Transmitters with backlit display and sensor backup functionality are
designed with safety in mind to keep your plant, equipment and personnel safe. For TMT162 details see
Technical Information.
Deltabar S/Cerabar S
The evolution series of Cerabar S/Deltabar S represents a decisive step ahead in making pressure
instrumentation better and safer for the process industry. The development of new products thrives especially
on the knowledge, commitment and experience of staff members. Permanent high performance can only be
achieved if dedicated and enthusiastic people provide their ideas. Endress+Hauser's instruments are not only
supposed to distinguish themselves for customers and users by technological novelties but also by the presence
of people supporting this progress, be it in service, sales or production. For Deltabar S & Cerabar S details see
Technical Information.

2 Endress+Hauser
TH13, TH14, TH15

Equipment architecture The single and duplex element RTDs are designed to measure temperature in a variety of processes and
laboratory applications. These RTDs are specifically designed for use in two different process temperature
ranges and they will provide accurate and repeatable temperature measurement through a broad temperature
range of -328 to 1112 °F (-200 to 600 °C). Low range thin film RTDs -58 to 392 °F (-50 to 200 °C) are
constructed using silver plated and copper internal leads, PTFE wire insulations with potting compounds to
resist moisture penetration. High range RTDs -328 to 1112 °F (-200 to 600 °C) are constructed with nickel
internal leads inside swaged MgO insulated cables to allow higher temperature measurements at the RTD
element and to provide higher temperature lead protection along the sheath.

Measurement range Construction Model code (class and type of sensor) max. range

TH13-_ _ _ _ _ (A/C/E/G/J/L) _ _ _ _ _

Low temperature range TH14-_ _ _ _ _ (A/C/E/G/J/L) _ _ _ _ _ -58 to 392 °F (-50 to 200 °C)

TH15-_ _ _ (A/C/E/G/J/L) _ _ _ _ _

TH13-_ _ _ _ _ (B/D/F/H/K/M) _ _ _ _ _

High temperature range TH14-_ _ _ _ _(B/D/F/H/K/M) _ _ _ _ _ -328 to 1112 °F (-200 to 600 °C)

TH15-_ _ _ (B/D/F/H/K/M) _ _ _ _ _ _

! Note!
Options J, K, L, M are duplex platinum elements of two sensors inside the same sheath.

Calibration specifications 3 point sensor calibration


-40 to 0 °C 0 to 100 °C +40 to 215 °C

-40 to 32 °F 32 to 212 °F 104 to 420 °F

Minimum length requirements for calibrated sensors = 6"

! Note!
Use option code ’B’ (Block: Test; calibration) for RTD calibration, the three temperature points need to be
specified in 5 °C (9 °F) increments.
The manufacturer provides comparison temperature calibrations from -40 to +215 °C (-40 to +420 °F) on the
international temperature scale of 1990. Calibrations are traceable to standards maintained by the national
institute of standards and technology (NIST). Calibration services are in conformance with ASTM E220, IEC
17025 and ANSI/NCSL Z540-1-1994. The report of calibration is referenced to the serial number of the RTD
assembly.
Three point calibrations are provided, given that the specified temperatures are within the recommended range
and the minimum length requirements are met as specified. The minimum length is based on overall length ’x’
of the spring loaded insert.

Endress+Hauser 3
TH13, TH14, TH15

Electronics
Family of temperature Measurement assemblies with iTEMP® transmitters are an installation ready solution to improve the
transmitters functionality of temperature measurement by increasing accuracy and reliability when compared to direct
wired sensors. Overall installation costs are lower than with direct wired sensors, since an inexpensive pair of
signal (4 to 20 mA) wires can be run over long distances.

PC programmable devices PC programmable head transmitters offer you extreme flexibility and help control costs with the ability to stock
TMT180 and TMT181 one device and program it for your needs. Regardless of your choice of output, all iTEMP® transmitters can be
configured quickly and easily with a PC. To help you with this task, Endress+Hauser offers free software
ReadWin® 2000 which can be downloaded from our website. Go to www.readwin2000.com to download
ReadWin® 2000 today. For details see Technical Information.

HART® TMT182 head HART® communication is all about easy, reliable data access and getting better information more
transmitter inexpensively. iTEMP® transmitters integrate seamlessly into your existing control system and provide painless
access to preventative diagnostic information.
Configuration with a DXR275 or 375 hand-held or a PC with configuration program (FieldCare, ReadWin®
2000) or configure with AMS or PDM. For details, see Technical Information.

Field transmitter TMT162 - Field transmitter with HART® communication, FOUNDATION Fieldbus™ protocol and blue backlit display.
Dual compartment housing Can be read easily from a distance, in sunlight and at night. Large measurement value, bargraph and fault
indication display. Benefits are: dual sensor input, highest reliability in harsh industrial environments,
mathematic functions, thermometer drift monitoring, sensor back-up functionality, corrosion detection and
sensor transmitter matching by accepting Callendar Van Dusen constants. For details, see Technical
Information.

Field transmitter TMT142 - Field transmitter with HART® communication. The one channel TMT142 allows for cost effective replacement
Single compartment housing of smaller transmitters with tiny display and old style analog transmitters. Large and brilliant blue backlit
display. Regardless of whether you install the transmitter in a dark location or in direct sunlight, you still get a
clear temperature reading. Reliable temperature measurement through advanced diagnostics. For details, see
Technical Information.

PROFIBUS® PA TMT184 head Universally programmable head transmitter with PROFIBUS®-PA fieldbus communication. Converting various
transmitter input signals into a digital output signal. High accuracy in the total ambient temperature range. Swift and easy
operation, visualisation and maintenance using a PC direct from the control panel, e. g. using operating
software such as FieldCare, Simatic PDM or AMS. DIP switch for address setting, makes start up and
maintenance save and reliable. For details, see Technical Information.

Performance characteristics
Response time 63% response time per ASTM E644

RTD assembly TH15 without thermowell


Construction RTD insert ø ¼"

High temperature range 3s

Low temperature range 9s

! Note!
Response time for the sensor assembly without transmitter.

4 Endress+Hauser
TH13, TH14, TH15

Response time examples for RTD assemblies with thermowell TH13 and TH14
Construction Stepped thermowell Tapered thermowell ¾" straight thermowell

High temperature range 20 s 25 s 30 s

Low temperature range 25 s 30 s 35 s

! Note!
Response times for RTD assemblies with thermowell are provided for general design guidance without
transmitter
When the temperature of a process media changes, the output signal of a RTD assembly follows this change
after a certain time delay. The physical cause is the time related to heat transfer from the process media through
the thermowell and the insert to the sensor element (RTD). The manner in which the reading follows the
change in temperature of the assembly over time is referred to as the response time. Variables that influence
or impact the response time are:
• Wall thickness of thermowell
• Spacing between RTD insert and thermowell
• Sensor packaging
• Process parameters such as media, flow velocity, etc.

Maximum measured error RTD corresponding to IEC 60751

Class max. Tolerances (°C)


A ±(0.15 + 0.002 · |t|1), Temperature range: -100 °C to 450 °C

B ±(0.3 + 0.005 · |t|1), Temperature range: -200 °C to 600 °C

1) |t| = absolute value °C

! Note!
For measurement errors in °F, calculate using equation above in °C, then multiply the outcome by 1.8.

Measurement accuracy
transmitter
TMT180 TMT181 multi- TMT182 TMT184 TMT162 FF TMT142 and TMT162
Pt100 PCP functional PCP HART® PROFIBUS®- Field trans- HART® Field transmitter
PA mitter

Accuracy

Digital D/A2

0.36 °F (0.2 °C) 0.36 °F (0.2 °C) 0.36 °F (0.2 °C) 0.27 °F 0.18 °F 0.18 °F 0.02%
or 0.08%1 or 0.08%2 or 0.08%2 (0.15 °C) (0.1 °C) (0.1 °C)

1) % is related to the adjusted measurement range (the larger value applies)


2) % relates to the set span. Accuracy = digital + D/A accuracy

Transmitter long-term ≤ 0.18 °F / year (≤ 0.1 °C/year) or ≤ 0.05% / year


stabiltiy Data under reference conditions; % relates to the set span. The larger value applies.

Insulation resistance Insulation resistance between terminals and probe sheath, test voltage 250 V.
• ≥100 MΩ at 77 °F (25 °C)
• ≥10 MΩ at 572 °F (300 °C)

Endress+Hauser 5
TH13, TH14, TH15

Self heating RTD elements are not self-powered and require a small current be passed through the device to provide a
voltage that can be measured. Self-heating is the rise of temperature within the element itself, caused by the
current flowing through the element. This self-heating appears as a measurement error and is affected by the
thermal conductivity and velocity of the process being measured; it is negligible when an Endress+Hauser
iTEMP® temperature transmitter is connected.

Sensor current Sensor current of Endress+Hauser iTEMP® transmitters

Transmitter type Sensor current

TMT180 & TMT181 PCP ≤ 0.6 mA

TMT182 HART® ≤ 0.2 mA

TMT184 PROFIBUS®-PA ≤ 0.2 mA

TMT162 HART®, FF Field transmitter ≤ 0.3 mA

TMT142 HART® Field transmitter ≤ 0.3 mA

Galvanic isolation Galvanic isolation of Endress+Hauser iTEMP® transmitters (input/output)

Transmitter type Galvanic isolation

TMT181 PCP Û = 3.75 kV AC

TMT182 HART®

TMT184 PROFIBUS®-PA
U = 2 kV AC
TMT162 HART®, FF Field transmitter

TMT142 HART® Field transmitter

6 Endress+Hauser
TH13, TH14, TH15

Wiring
Wiring diagrams Type of sensor connection

Head mounted transmitter Field mounted transmitter

T09-TH1112xx-04-xx-XX-ae-000 T09-TH131415-04-xx-xx-ae-000

Terminal block mounted

T09-TH1112xx-04-xx-XX-ae-001

! Note!
The blocks and transmitters are shown as they sit inside the heads in reference to the conduit opening.

Endress+Hauser 7
TH13, TH14, TH15

Wire specifications 24AWG, 19 strand silver plated copper with 0.010” PTFE extruded outer.

Electrical connection

Flying leads, standard 3" for wiring in connection head, head mounted transmitter or terminal block mounted

Flying leads, 5½" for wiring with TMT162 or TMT142 assemblies

Design of leads

Flying leads 3" or 5½" with


brass crimped sleeves

Installation conditions

Orientation No restrictions for installation orientation.

Installation instructions

T09-TH1314x15-11-xx-xx-ae-000

Examples for pipe installation - In pipes with a small cross section the sensor tip should reach or extend slightly past the
center line of the pipe (=U).
A: TH13 assembly socket weld installation
B: Threaded, tilted installation of TH13 assembly
C: Flange installation of TH14 assembly

8 Endress+Hauser
TH13, TH14, TH15

Immersion
Minimum immersion per ASTM E644, ∆T ≤ 0.09 °F (0.05 °C)
Immersion RTD assembly TH15 without thermowell

Construction RTD Insert ø ¼"


Minimum Immersion (Inch)

High temperature range 1¼"

Low temperature range ¾"

For temperature assemblies with themowell (TH13 and TH14) the minimum immersion is the depth to which
the thermowell is immersed in the medium, measured from the tip. To minimize errors from ambient
temperature the following minimum immersion lengths are recommended:

Construction Minimum Immersion (Inch)

Stepped thermowell 2½"

Tapered thermowell 4½"


¾" straight thermowell 4"

Weld in thermowell 4½"

Environmental conditions

Ambient temperature Housing without head-mounted transmitter


• Aluminum pressure die-cast housing -40 to 300 °F (-40 to 150 ºC)
• Plastic housing -40 to 185 °F (-40 to 85 °C)
• Deep drawn SS housing without display -40 to 300 °F (-40 to 150 °C)
Housing with head-mounted transmitter
• -40 to 185 °F (-40 to 85 °C)
Field transmitter without display
• -40 to 185 °F (-40 to 85 °C)

Shock and vibration resistance 4g / 2 to 150 Hz as per IEC 60 068-2-6

Process conditions
Thermowells are used in measuring the temperature of a moving fluid in a conduit, where the stream exerts
an appreciable force. The limiting value for the thermowells is governed by the temperature, the pressure and
the speed of the medium, the immersion length, the materials of the thermowells and the medium, etc.
Calculations for stress and vibration of thermowells can be done according to ASME PTC 19.3-1974 standard,
please consult Endress+Hauser.

Endress+Hauser 9
TH13, TH14, TH15

Mechanical construction
Design, dimensions All dimensions in inches. For the values related to this graphic please refer to the tables and equations below.

T09-TH131415-06-xx-xx-ae-000

*For TH13 thermowells with ½"NPT - 1" Process thread length and ¾" Hex length dimensions are reversed.
Pos. P: Pipe size
Pos. Q: Thermowell diameter
Pos. T: Lag dimension (see product structure)
Pos. U: Thermowell immersion length
Pos. XA, A: Immersion length RTD sensor; Thermowell drilled length
Pos. X: Insert overall length

10 Endress+Hauser
TH13, TH14, TH15

All thermowells are marked with:


• Material I.D.
• CRN# (Canadian Registration Number)
• Heat No.

Dimensions of TH13

U E T Process Shape of Thermowell øQ


connection

2½", 4½", 7½", Hex nipple = 1" 3" or ½" NPT Stepped (Standard duty) 5/8"
11
10½" or specified length Tapered (Heavy duty) /16"
specified length Nipple Union 1" to 6" in
¾" NPT Stepped (Standard duty) ¾"
2" to 18" in Nipple ½" increments
Tapered (Heavy duty) 7/8"
½" increments (NUN) = 4" or 7"
Material: 1" NPT Stepped (Standard duty) 7/8"
Steel or 316SS Tapered (Heavy duty) 1 1/16"

¾" Socket weld Stepped (Standard duty) ¾"


Tapered (Heavy duty) ¾"

1" Socket weld Stepped (Standard duty) 7/8"


Tapered (Heavy duty) 1"

¾" weld in Tapered (Heavy duty) 1.050"


1" weld in Tapered (Heavy duty) 1.315"

Immersion length RTD sensor = Thermowell drilled length XA = A = U + 1½" + T


Insert overall length X = A + E + 1"

P = Pipe size
• Nom. ¾"; Dia. = 1.050"
• Nom. 1"; Dia. = 1.315"

Dimensions of TH14
Flange rating: ASME B16.5

U E T Flange size ø Q, Tapered


version

2", 4", 7", 10" Hex nipple = 1" specified length 1" 7/8"
specified length or 1" to 10" in
2" to 18" Nipple Union ½" increments 1½" 11/16"
in ½" increments Nipple 2" 11/16"
(NUN) = 4" or 7"
Material:
Steel or 316SS

Immersion length RTD sensor - Thermowell drilled length XA = A = U + 2" + T


Insert overall length X = A + E + 1"

Dimensions of TH15 (without Thermowell)

Immersion length RTD sensor XA E


4", 6", 9", 12", 14" Hex nipple = 1"
specified length 4" to 30" in ½" increments or
Nipple Union Nipple (NUN) = 4" or 7"

Weight From 1 to 10 lbs

Endress+Hauser 11
TH13, TH14, TH15

Material Wetted parts 316SS


Thermowell material
Wetted parts 316SS for usage up to 1700 °F (927 °C). 316SS has good oxidation and corrosion resistance in a
wide range of industrial environments with improved resistance to mild acid and pitting corrosion. Exposure
to carbide precipitation, reduces corrosion resistance in the 800 to 1000 °F (427 to 538 °C) temperature range.
Good mechanical properties for -300 to 1450 °F (-184 to 788 °C) temperature range. Generally regarded as
standard protection tube material, other materials are available upon request.

System components
Housing

Type of housing Specification

Connection head Aluminum • Material: Die-cast Aluminum head


• Sensor connection: ½" NPT Female
• Cable entry: ½" NPT or ¾" NPT Female. ½" NPT has a Al reducer bushing
• Body paint: Spray SPU, RAL5012
Cover paint: Spray SPU, RAL7035
• Coating thread (body-cover), lubricant acc. E+H standard, MgO coating;
benefits include ease of opening/closing cover and improved thread
engagement. Improves lifetime of the connection head.
• Degree of protection NEMA 4X (IP 66)

T09-TH11xxxx-06-xx-xx-ae-001

Connection head plastic • Polyprolylene, FDA compliant


• Sensor connection: ½" NPT Female
• Cable entry: ½" NPT or ¾" NPT Female. ½" NPT with nylon reducer bushing
(FDA compliant)
• Degree of protection NEMA 4X

T09-TH11xxxx-06-xx-xx-ae-000

Temperature field transmitter iTEMP® TMT162 • Material: Die-cast aluminum housing AlSi10Mg with powder coating on
polyester base
• Separate electronics compartment and connection compartment
• Display rotatable in 90° increments
• Cable entry: 2 x ½" NPT
• Degree of protection NEMA 4X (IP 67)
• Brilliant blue backlit display with ease of visibility in bright sunshine or pitch
darkness
• Gold plated terminals to avoid corrosion and additional measurement errors
Details see Technical Information (see 'Documentation')

T09-TMT162ZZ-06-00-xx-ae-001

12 Endress+Hauser
TH13, TH14, TH15

Type of housing Specification


® ®
Temperature field transmitter iTEMP HART TMT142 • Material: Die-cast aluminum housing AlSi10Mg with powder coating on
polyester base
• Display rotatable in 90° increments
• Cable entry: 3 x ½" NPT
• Degree of protection NEMA 4X (IP 67)
• Brilliant blue backlit display with ease of visibility in bright sunshine or pitch
darkness
• Gold plated terminals to avoid corrosion and additional measurement errors
Details see Technical Information (see 'Documentation')

T09-TMT142ZZ-06-00-06-ae-001

Connection head deep drawn stainless steel, TA20J style • Material: Deep drawn stainless steel AISI 316L SS (hygienic design)
• Optional with display and/or head transmitter
• Sensor connection: ½" NPT female
• Cable entry: ½" NPT female
• Degree of protection NEMA 4X (IP 66)
Display:
• 4 digits 7-segments LC display (loop powered)
• Maximum error: 0.1% of programmed range
• Loop drop: 2.5 V at 22 mA
• Max. ambient temperature: -4 to 160 °F (-20 to 70 °C)
The programming is executed through 3 keys mounted on the bottom of the
display.

a0005938

* dimensions with optional display

Head transmitter

Type of transmitter) Specification


®
iTEMP TMT18x • Material
Housing: PC
Potting: PUR
• Terminals: Cable up to max. 16 AWG (secure screws) or with wire end
ferrules
• Eyelets for easy connection of a HART®-handheld terminal with alligator
clips
• Degree of protection NEMA 4 (see also type of connection head)
Details see Technical Information (see ’Documentation’)

R09-TMT182ZZ-06-06-xx-ae-001

iTEMP® PA TMT184

T09-TMT184ZZ-06-06-xx-ae-001

Endress+Hauser 13
TH13, TH14, TH15

Fieldbus connector Type (dimensions in inches [mm]) Specification

Fieldbus connector to PROFIBUS® -PA or • Ambient temperature: -40 to 300 °F (-40 to 150 °C)
FOUNDATION Fieldbus™ • Degree of protection IP 67
Wiring diagram:

T09-FFCONNEC-06-xx-xx-ae-000 a0006023

Pos. A: PROFIBUS® -PA FOUNDATION Fieldbus™


M12 on PROFIBUS® -PA connector Pos 1: grey (shield) Pos 1: blue (-)
7/8-16 UNC on FOUNDATION Fieldbus™ Pos 2: brown (+) Pos 2: brown (+)
connector Pos 3: blue (-) Pos 3: not connected
Pos 4: not connected Pos 4: ground (green/yellow)

Certificates and approvals


CE Mark The iTEMP® Series of temperature transmitters complies with the legal requirements laid out within the EU
regulations.

Other standards and • IEC 60529:


guidelines Degrees of protection by housing (IP-Code).
• IEC 61010:
Safety requirements for electrical measurement, control and laboratory instrumentation.
• ASTM E644:
American society for testing and materials, standard test methods for testing industrial
resistance thermometers.
• NEMA - ANSI / NEMA 250
Standardization association for the electrical industry.
• IEC 60571
Industrial platinum resistance thermometer
• ASME PTC 19.3 - 1974
Performance test codes

UL Temperature transmitters are recognized components to UL 3111-1 (iTEMP® Series) except for TMT184
PROFIBUS®-PA.

CSA GP The installed and assembled transmitters (iTEMP® Series) are CSA GP approved, except TMT184 PROFIBUS®
PA

14 Endress+Hauser
TH13, TH14, TH15

Ordering information
Product structure, RTD TH13- RTD assembly in thermowell, TH13
assembly in thermowell TH13
TW Immersion length U:
1 2½ inch
2 4½ inch
3 7½ inch
4 10½ inch
8 .... inch (0.5" increments)
Y special

Process connection, TW Material, 1 inch:


A1 ½" NPT 316SS
A2 ¾" NPT 316SS
A3 1" NPT 316SS
B1 Socket weld ¾" 316SS
B2 Socket weld 1" inch 316SS
C1 Weld in ¾" 316SS
C2 Weld in 1" inch 316SS
YY Special

Shape of TW:
2 Stepped, Standard Duty
3 Tapered, Heavy Duty
9 Special

Lag of TW T:
A None
E 3 inch
X ... inch (0.5" increments)
Y Special

Extension:
1 Hex nipple 316SS, E=1"
2 Nipple Union Nipple 316SS, E=4"
3 Hex nipple steel, E=1"
4 Nipple Union Nipple, steel, E=4"
5 Nipple Union Nipple, steel, E=7"
6 Nipple Union Nipple, 316SS, E=7"
9 Special

Class; Type Sensor IEC751; Connection:


A 1 Pt100 class B, 3 wire low, -50 to 200 °C (-58 to 392 °F)
B 1 Pt100 class B, 3 wire high, -200 to 600 °C (-328 to 1112 °F)
C 1 Pt100 class A, 3 wire low, -50 to 200 °C (-58 to 392 °F)
D 1 Pt100 class A, 3 wire high, -200 to 600 °C (-328 to 1112 °F)
E 1 Pt100 class B, 4 wire low, -50 to 200 °C (-58 to 392 °F)
F 1 Pt100 class B, 4 wire high, -200 to 600 °C (-328 to 1112 °F)
G 1 Pt100 class A, 4 wire low, -50 to 200 °C (-58 to 392 °F)
H 1 Pt100 class A, 4 wire high, -200 to 600 °C (-328 to 1112 °F)
J 2 Pt100 class B, 3 wire low, -50 to 200 °C (-58 to 392 °F)
K 2 Pt100 class B, 3 wire high, -200 to 600 °C (-328 to 1112 °F)
L 2 Pt100 class A, 3 wire low, -50 to 200 °C (-58 to 392 °F)
M 2 Pt100 class A, 3 wire high, -200 to 600 °C (-328 to 1112 °F)
Y Special

TH13- ← Order code (Part 1)

Endress+Hauser 15
TH13, TH14, TH15

Enclosure; communication:
A None
B E+H blue Al + cover, ½" NPT cable entry
C E+H blue Al + cover, ¾" NPT cable entry
D Plastic PP white ½" NPT cable entry
E Plastic PP white ¾" NPT cable entry
F SS316L (TA20J), ½" NPT
G SS316L (TA20J), LCD, ½" NPT
H AL Field Housing, 1 Input, ½" NPT, HART
I AL Field Housing, 1 Input, Display, HART, ½" NPT
J AL Field Housing, 2 Input, ½" NPT, HART
K AL Field Housing, 2 Input, Display, HART, ½" NPT
L AL Field Housing, 2 Input, ½" NPT, FF
M AL Field Housing, 2 Input, Display, FF, ½" NPT
Y Special

Electrical connection:
A Programmable RTD TMT180
C Programmable TMT181 NON Ex
D Programmable TMT181 FM IS
E Programmable TMT181 CSA IS
F Profibus PA TMT184, non Ex
G Profibus PA TMT184, FM IS
H Profibus PA TMT184, CSA IS
I TMT162, non Ex, Dual Compartment
J TMT162, FM IS, Dual Compartment
K TMT162, CSA IS, Dual Compartment
L HART TMT142 non Ex, Single Compartment
M HART TMT142, FM IS, Single Compartment
N HART TMT142, CSA IS, Single Compartment
O HART TMT182, FM IS Advanced Diagnostic
P HART TMT182 NON Ex
R HART TMT182 FM IS
T HART TMT182 CSA IS
Y Special
2 Flying Leads
3 Terminal block

Additional option:
1 None
2 Profibus PA Plug M12
3 Foundation Fieldbus Plug 7/8"
9 special version

Test; Calibration:
A None
B Sensor calibration certificate
Y Special version

Model:
K Standard model, North American region
Y Special version

TH13- ← Order code (complete)

16 Endress+Hauser
TH13, TH14, TH15

Product structure, RTD TH14- RTD assembly in flanged thermowell, TH14


assembly in flanged
TW Immersion length U
thermowell TH14
1 2 inch
2 4 inch
3 7 inch
4 10 inch
8 .... inch (0.5" increments)
Y Special version

Flange size; TW Material per 1 inch:


A 1 inch 316SS
B 1½ inch 316SS
C 2 inch 316SS
Y Special

Rating; Type:
1 150 psi; RF
2 300 psi; RF
3 600 psi; RF
9 Special

Shape of TW; Welding:


1 Straight; standard
2 Tapered; standard
3 Straight; full penetration
4 Tapered; full penetration
9 Special

Lag of TW, T:
A None
X .... inch (0.5" increments)
Y Special

Extension:
1 Hex nipple 316SS, E=1"
2 Nipple Union Nipple 316SS, E=4"
3 Hex nipple steel, E=1"
4 Nipple Union Nipple, steel, E=4"
5 Nipple Union Nipple, steel, E=7"
6 Nipple Union Nipple, 316SS, E=7"
9 Special

Class; Type Sensor IEC751; Connection:


A 1 Pt100 class B, 3 wire low, -50 to 200 °C (-58 to 392 °F)
B 1 Pt100 class B, 3 wire high, -200 to 600 °C (-328 to 1112 °F)
C 1 Pt100 class A, 3 wire low, -50 to 200 °C (-58 to 392 °F)
D 1 Pt100 class A, 3 wire high, -200 to 600 °C (-328 to 1112 °F)
E 1 Pt100 class B, 4 wire low, -50 to 200 °C (-58 to 392 °F)
F 1 Pt100 class B, 4 wire high, -200 to 600 °C (-328 to 1112 °F)
G 1 Pt100 class A, 4 wire low, -50 to 200 °C (-58 to 392 °F)
H 1 Pt100 class A, 4 wire high, -200 to 600 °C (-328 to 1112 °F)
J 2 Pt100 class B, 3 wire low, -50 to 200 °C (-58 to 392 °F)
K 2 Pt100 class B, 3 wire high, -200 to 600 °C (-328 to 1112 °F)
L 2 Pt100 class A, 3 wire low, -50 to 200 °C (-58 to 392 °F)
M 2 Pt100 class A, 3 wire high, -200 to 600 °C (-328 to 1112 °F)
Y Special

TH14- ← Order code (Part 1)

Endress+Hauser 17
TH13, TH14, TH15

Enclosure; communication:
A None
B E+H blue Al + cover, ½" NPT cable entry
C E+H blue Al + cover, ¾" NPT cable entry
D Plastic PP white ½" NPT cable entry
E Plastic PP white ¾" NPT cable entry
F SS316L (TA20J), ½" NPT
G SS316L (TA20J), LCD, ½" NPT
H AL Field Housing, 1 Input, ½" NPT, HART
I AL Field Housing, 1 Input, Display, HART, ½" NPT
J AL Field Housing, 2 Input, ½" NPT, HART
K AL Field Housing, 2 Input, Display, HART, ½" NPT
L AL Field Housing, 2 Input, ½" NPT, FF
M AL Field Housing, 2 Input, Display, FF, ½" NPT
Y Special

Electrical connection:
A Programmable RTD TMT180
C Programmable TMT181 NON Ex
D Programmable TMT181 FM IS
E Programmable TMT181 CSA IS
F Profibus PA TMT184, non Ex
G Profibus PA TMT184, FM IS
H Profibus PA TMT184, CSA IS
I TMT162, non Ex, Dual Compartment
J TMT162, FM IS, Dual Compartment
K TMT162, CSA IS, Dual Compartment
L HART TMT142 non Ex, Single Compartment
M HART TMT142, FM IS, Single Compartment
N HART TMT142, CSA IS, Single Compartment
O HART TMT182, FM IS Advanced Diagnostic
P HART TMT182 NON Ex
R HART TMT182 FM IS
T HART TMT182 CSA IS
Y Special
2 Flying Leads
3 Terminal block

Additional option:
1 None
2 Profibus PA Plug M12
3 Foundation Fieldbus Plug 7/8"
9 special version

Test; Calibration:
A None
B Sensor calibration certificate
Y Special version

Model:
K Standard model, North American region
Y Special version

TH14- ← Order code (complete)

18 Endress+Hauser
TH13, TH14, TH15

Product structure, RTD TH15- RTD assembly, TH15


assembly TH15
Immersion length XA
1 4 inch
2 6 inch
3 9 inch
4 12 inch
5 14 inch
8 .... inch (0.5" increments)
Y Special version

Sheath diameter price per 2 inch:


A ¼ inch 316SS
Y Special

Extension:
1 Hex nipple 316SS, E=1"
2 Nipple Union Nipple 316SS, E=4"
3 Hex nipple steel, E=1"
4 Nipple Union Nipple, steel, E=4"
5 Nipple Union Nipple, steel, E=7"
6 Nipple Union Nipple, 316SS, E=7"
9 Special

Class; Type Sensor IEC751; Connection:


A 1 Pt100 class B, 3 wire low, -50 to 200 °C (-58 to 392 °F)
B 1 Pt100 class B, 3 wire high, -200 to 600 °C (-328 to 1112 °F)
C 1 Pt100 class A, 3 wire low, -50 to 200 °C (-58 to 392 °F)
D 1 Pt100 class A, 3 wire high, -200 to 600 °C (-328 to 1112 °F)
E 1 Pt100 class B, 4 wire low, -50 to 200 °C (-58 to 392 °F)
F 1 Pt100 class B, 4 wire high, -200 to 600 °C (-328 to 1112 °F)
G 1 Pt100 class A, 4 wire low, -50 to 200 °C (-58 to 392 °F)
H 1 Pt100 class A, 4 wire high, -200 to 600 °C (-328 to 1112 °F)
J 2 Pt100 class B, 3 wire low, -50 to 200 °C (-58 to 392 °F)
K 2 Pt100 class B, 3 wire high, -200 to 600 °C (-328 to 1112 °F)
L 2 Pt100 class A, 3 wire low, -50 to 200 °C (-58 to 392 °F)
M 2 Pt100 class A, 3 wire high, -200 to 600 °C (-328 to 1112 °F)
Y Special

Enclosure; communication:
A None
B E+H blue Al + cover, ½" NPT cable entry
C E+H blue Al + cover, ¾" NPT cable entry
D Plastic PP white ½" NPT cable entry
E Plastic PP white ¾" NPT cable entry
F SS316L (TA20J), ½" NPT
G SS316L (TA20J), LCD, ½" NPT
H AL Field Housing, 1 Input, ½" NPT, HART
I AL Field Housing, 1 Input, Display, HART, ½" NPT
J AL Field Housing, 2 Input, ½" NPT, HART
K AL Field Housing, 2 Input, Display, HART, ½" NPT
L AL Field Housing, 2 Input, ½" NPT, FF
M AL Field Housing, 2 Input, Display, FF, ½" NPT
Y Special

TH15- ← Order code (part 1)

Endress+Hauser 19
TH13, TH14, TH15

Electrical connection:
A Programmable RTD TMT180
C Programmable TMT181 NON Ex
D Programmable TMT181 FM IS
E Programmable TMT181 CSA IS
F Profibus PA TMT184, non Ex
G Profibus PA TMT184, FM IS
H Profibus PA TMT184, CSA IS
I TMT162, non Ex, Dual Compartment
J TMT162, FM IS, Dual Compartment
K TMT162, CSA IS, Dual Compartment
L HART TMT142 non Ex, Single Compartment
M HART TMT142, FM IS, Single Compartment
N HART TMT142, CSA IS, Single Compartment
O HART TMT182, FM IS Advanced Diagnostic
P HART TMT182 NON Ex
R HART TMT182 FM IS
T HART TMT182 CSA IS
Y Special
2 Flying Leads
3 Terminal block

Documentation Requirement:
1 Standard
9 Other

Test; Calibration:
A None
B Sensor calibration certificate
Y Other

Model:
K Standard model, North American region
Y Other

Additional option:
1 None
2 Profibus PA Plug M12
3 Foundation Fieldbus Plug 7/8"
9 special version

TH15- ← Order code (complete)

20 Endress+Hauser
TH13, TH14, TH15

Documentation
• Compact instructions TH13 RTD assembly in thermowell (KA190r/24/ae)
• Compact instructions TH14 RTD assembly in flanged thermowell (KA192r/24/ae)
• Compact instructions TH15 RTD assembly - spring loaded (KA195r/24/ae)
• Technical information Temperature field transmitter iTEMP® TMT162 (TI086r/24/ae)
• Technical information Temperature field transmitter iTEMP® HART® TMT142 (TI107r/24/ae)
• Technical information Temperature head transmitter iTEMP® Pt TMT180 (TI088r/24/ae)
• Technical information Temperature head transmitter iTEMP® PCP TMT181 (TI070r/24/ae)
• Technical information Temperature head transmitter iTEMP® HART® TMT182 (TI078r/24/ae)
• Technical information Temperature head transmitter iTEMP® PA® TMT184 (TI079r/24/ae)

Application example:
• Technical information Energy manager RMS621 (TI092r/24/ae)
• Technical information Cerabar S (TI383r/24/ae)
• Technical information Deltabar S (TI384r/24/ae)

Endress+Hauser 21
TH13, TH14, TH15
TH13, TH14, TH15
TH13, TH14, TH15

United States Canada Mexico

Endress+Hauser, Inc. Endress+Hauser Canada Endress+Hauser (Mexico) S.A. de C.V.


2350 Endress Place 1075 Sutton Drive Av. Gustavo Baz No. 43
Greenwood, IN 46143 Burlington, ON L7L 5Z8 Fracc. Bosques de Echegaray
Tel: 317-535-7138 Tel: 905-681-9292 Naucalpan de Juárez, C.P. 53310,
Sales: 888-ENDRESS 800-668-3199 Estado de Mexico
Service: 800-642-8737 FAX: 905-681-9444 Mexico
FAX: 317-535-8498 www.ca.endress.com Tel: (52) 55 5371 1110
[email protected] FAX: (52) 55 5371 1128
www.us.endress.com E-mail: [email protected]

TI110R/24/ae/06.06
FM+SGML 6.0 ProMoDo

You might also like