0% found this document useful (0 votes)
117 views3 pages

EasyLogic PM2000 Series - METSEPM2210

The EasyLogic PM2210 is a power and energy meter that measures total harmonic distortion and various electrical parameters including voltage, current, power, energy, and power quality values. It has accuracy of class 1 for energy measurement, supports communication via MODBUS protocol, and has front protection of IP54.

Uploaded by

Vinay Saketh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
117 views3 pages

EasyLogic PM2000 Series - METSEPM2210

The EasyLogic PM2210 is a power and energy meter that measures total harmonic distortion and various electrical parameters including voltage, current, power, energy, and power quality values. It has accuracy of class 1 for energy measurement, supports communication via MODBUS protocol, and has front protection of IP54.

Uploaded by

Vinay Saketh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Product data sheet METSEPM2210

Characteristics EasyLogic PM2210, Power & Energy meter, Total


Harmonic, LCD, Pulse, class 1

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Main
Range EasyLogic
Product name EasyLogic PM2200
Device short name PM2210
Product or component type Power meter

Complementary
Device application Power monitoring
Sub billing
Power quality analysis Total harmonic distortion
Type of measurement Apparent power (min/max, total)
Active and reactive power (min/max, total)
Current (min/max, avg)
Voltage (min/max, avg)
Frequency (min/max, avg)
Total current harmonic distortion THD (I) (per phase)
Total voltage harmonic distortion THD (U) (per phase)
Power factor (min/max, avg)
Apparent energy (total)
Active and reactive energy (total)
Metering type Apparent power S, S1, S2, S3
Active, reactive, apparent energy (signed, four quadrant)
Demand power P, Q, S
Peak demand power PM, QM, SM
Reactive power Q, Q1, Q2, Q3
Peak demand currents
Unbalance current
Current I, I1, I2, I3
Active power P, P1, P2, P3
Calculated neutral current
Voltage U, U21, U32, U13, V, V1, V2, V3
Accuracy class Class 1 (active energy according to IEC 62053-21)
Class 1 (reactive energy according to IEC 62053-24)
Measurement accuracy +/- 0.05 % frequency
+/- 1 % reactive energy

Jul 20, 2019


1
+/- 0.5 % current
+/- 0.5 % voltage
+/- 0.01 power factor
+/- 1 % active power
+/- 1 % apparent power
+/- 1 % active energy
Measurement current 5...6000 mA
Measurement voltage 35...480 V AC 50/60 Hz between phases
20...277 V AC 50/60 Hz between phase and neutral
480...999000 V AC 50/60 Hz with external VT
Frequency measurement range 45...65 Hz
[Us] rated supply voltage 44...277 V AC +/- 10 % (45...65 Hz)
44...277 V DC +/- 10 %
Network frequency 60 Hz
50 Hz
Ride-through time 100 ms 120 V AC typical
400 ms 230 V AC typical
50 ms 125 V DC typical
[In] rated current 5A
1A
Power consumption in VA <= 6 VA at 277 V AC
Power consumption in W <= 3.3 W power lines (AC)
<= 2 W at 277 V power lines (DC)
Input impedance Current (impedance <= 0.3 mOhm)
Voltage (impedance > 5 MOhm)
Tamperproof of settings Protected by access code
Display type Backlit LCD
Display colour Monochrome
Display resolution 128 x 128 pixels
Demand intervals Configurable from 1 to 60 min
Information displayed Voltage
Current
Frequency
Energy consumption
Harmonic distortion
Demand current past value
Demand current present value
Demand power past value
Demand power present value
Power factor
Active power
Apparent power
Reactive power
Unbalanced in %
Harmonic amplitude
Control type 4 x button
Local signalling Green LED : module operating (RUN)
Red LED : output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh)
Number of inputs 2 pulse
Number of outputs 1 pulse
POP parameter Pulse: 20 ms (5...40 V DC, 20 mA max) 1...9999000 pulse/ k_h (kWh, kVAh, kVARh)
Impulse duration 20 ms
Communication port protocol POP
Sampling rate 64 samples/cycle
Cybersecurity Enable/disable communication ports
Communication service Remote monitoring
Language Russian
French
English
German
Portuguese
Chinese
Spanish
Product certifications CE conforming to IEC 61010-1

2
CULus conforming to UL 61010-1
EAC
CULus conforming to CSA C22.2 No 61010-1
RCM
C-Tick
Mounting mode Clip-on
Mounting position Vertical
Mounting support Framework
Provided equipment Installation guide 1
Measurement category Category III up to 480 V
Category II up to 480...600 V
Electrical insulation class Double insulation
Class II
Flame retardance V-0 conforming to UL 94
Connections - terminals Current transformer : bottom screw connection x 6
Voltage inputs : top screw connection x 4
Material Polycarbonate
Width 96 mm
Depth 76.09 mm total
61.64 mm embedded
Height 96 mm
Product weight 300 g
Compatibility code PM2210

Environment
Service life 7 yr
IP degree of protection IP30 (body) conforming to IEC 60529
IP54 (front) conforming to IEC 60529
Relative humidity 5...95 % 50 °C
Pollution degree 2
Ambient air temperature for operation -10...60 °C
Ambient air temperature for storage -25...70 °C
Operating altitude <= 2000 m
Electromagnetic compatibility Electrostatic discharge conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
Surge immunity test conforming to IEC 61000-4-5
Conducted RF disturbances conforming to IEC 61000-4-6
Magnetic field at power frequency conforming to IEC 61000-4-8
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
Emission tests conforming to FCC part 15 class A
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Overvoltage category III

Offer Sustainability
Sustainable offer status Green Premium product
RoHS (date code: YYWW) Compliant  - since  1601  -  Schneider Electric declaration of conformity
Schneider Electric declaration of conformity
REACh Reference not containing SVHC above the threshold
Reference not containing SVHC above the threshold
Product environmental profile Available
End of Life Information
Product end of life instructions Available