Lexium 32 & Motors - LXM32MD18M2
Lexium 32 & Motors - LXM32MD18M2
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Main
Range of product Lexium 32
Product or component type Motion servo drive
Device short name LXM32M
Format of the drive Book
Network number of phases Single phase
[Us] rated supply voltage 100...120 V (- 15...10 %)
200...240 V (- 15...10 %)
Supply voltage limits 170...264 V
85...132 V
Supply frequency 50/60 Hz (- 5...5 %)
Network frequency 47.5...63 Hz
EMC filter Integrated
Continuous output current 6 A (f = 8 kHz)
Output current 3s peak 10 A at 115 V for 5 s
Maximum continuous power 500 W at 115 V
3300 W at 400 V
Nominal power 0.5 kW at 115 V (f = 8 kHz)
1.8 kW at 400 V (f = 8 kHz)
Line current 8.5 A, THDI of 147 % at 115 V, without line choke
7.2 A, THDI of 88 % at 380 V, with external line choke of 1 mH
6 A, THDI of 98 % at 480 V, with external line choke of 1 mH
6.2 A, THDI of 159 % at 380 V, without line choke
Complementary
Switching frequency 8 kHz
Overvoltage category III
Leakage current <= 30 mA
Output voltage <= power supply voltage
Electrical isolation Between power and control
2
Product compatibility Servo motor BMH (70 mm, 1 motor stacks)
Servo motor BMH (70 mm, 3 motor stacks)
Servo motor BMH (100 mm, 2 motor stacks)
Servo motor BSH (70 mm, 3 motor stacks)
Servo motor BSH (100 mm, 1 motor stacks)
Servo motor BSH (100 mm, 2 motor stacks)
Width 68 mm
Height 270 mm
Depth 237 mm
Product weight 1.9 kg
Environment
Electromagnetic compatibility Conducted EMC at class A group 1 conforming to EN 55011
Conducted EMC at class A group 2 conforming to EN 55011
Conducted EMC at environment 2 category C3 conforming to EN/IEC 61800-3
Conducted EMC at category C2 conforming to EN/IEC 61800-3
Conducted EMC at environments 1 and 2 conforming to EN/IEC 61800-3
Electrostatic discharge immunity test at level 3 conforming to EN/IEC 61000-4-2
Susceptibility to electromagnetic fields at level 3 conforming to EN/IEC 61000-4-3
1.2/50 µs shock waves immunity test at level 3 conforming to EN/IEC 61000-4-5
Electrical fast transient/burst immunity test at level 4 conforming to EN/IEC 61000-4-4
Radiated EMC at class A group 2 conforming to EN 55011
Radiated EMC at category C3 conforming to EN/IEC 61800-3
Standards EN/IEC 61800-3
EN/IEC 61800-5-1
Product certifications CSA
RoHS
TÜV
UL
IP degree of protection IP20 conforming to EN/IEC 60529
IP20 conforming to EN/IEC 61800-5-1
Vibration resistance 1.5 mm peak to peak (f = 3...13 Hz) conforming to EN/IEC 60068-2-6
1 gn (f = 13...150 Hz) conforming to EN/IEC 60068-2-6
Shock resistance 15 gn for 11 ms conforming to EN/IEC 60028-2-27
Pollution degree 2 conforming to EN/IEC 61800-5-1
Environmental characteristic Classes 3C1 conforming to IEC 60721-3-3
Relative humidity Class 3K3 (5 to 85 %) without condensation conforming to IEC 60721-3-3
Ambient air temperature for operation 0...50 °C conforming to UL
Ambient air temperature for storage -25...70 °C
Type of cooling Integrated fan
Operating altitude <= 1000 m without derating
> 1000...3000 m with conditions
Offer Sustainability
Sustainable offer status Green Premium product
RoHS (date code: YYWW) Compliant - since 0930 - Schneider Electric declaration of conformity
Schneider Electric declaration of conformity
REACh Reference not containing SVHC above the threshold
Reference not containing SVHC above the threshold
Product environmental profile Available
End of Life Information
Product end of life instructions Available
Contractual warranty
Warranty period 18 months
3
Product data sheet LXM32MD18M2
Dimensions Drawings
Dimensions
4
Product data sheet LXM32MD18M2
Mounting and Clearance
Mounting Recommendations
LXM32•U45M2, •U90M2 and LXM32•U60N4 servo drives are cooled by natural convection. LXM32•D18M2, •D30M2, LXM32 •D12N4, •D18N4,
•D30N4 and •D72N4servo drives have an integrated fan.
When installing the servo drive in the enclosure, follow the instructions below with regard to the temperature and protection index:
● Provide sufficient cooling of the servo drive
● Do not mount the servo drive near heat sources
● Do not mount the servo drive on flammable materials
● Do not heat the servo drive cooling air by currents of hot air from other equipment and components, for example from an external braking resistor
● Mount the servo drive vertically (± 10%)
● If the servo drive is used above its thermal limits, control stops due to overtemperature
NOTE: For cables that are connected via the underside of the servo drive, a free space ≥ 200 mm/7.87 in. is required under the unit to comply
with the bending radius of the connection cables.
0°C…+ 50°C d ≥ 0 mm –
5
● Any apertures and/or fans must provide a flow rate at least equal to that of the servo drive fans (refer to characteristics).
● Use special filters with IP 54 protection.