So1000 Rev e

The document summarizes the specifications of the rƒsco so1000 Tube-to-Tube Gravity Handler. It can handle up to 8 tubes with a throughput of up to 14,400 units per hour. It has a temperature range of -60°C to +175°C and supports various package types from QFN 3mm to SO450 mil. The system offers high reliability, flexibility, and productivity for semiconductor testing.

Uploaded by

mhafizan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
456 views

So1000 Rev e

The document summarizes the specifications of the rƒsco so1000 Tube-to-Tube Gravity Handler. It can handle up to 8 tubes with a throughput of up to 14,400 units per hour. It has a temperature range of -60°C to +175°C and supports various package types from QFN 3mm to SO450 mil. The system offers high reliability, flexibility, and productivity for semiconductor testing.

Uploaded by

mhafizan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

rƒsco so1000

Tube-to-Tube Gravity Handler

Hi gh Pro d uc tiv ity


n Up to 8 Tubes Soak Capacity
n Best in class total cost of ownership
n Highest reliability
Full tri-Temp range -60°C to +175°C
F l ex i b i l i ty More than 1,500 systems in the field
n QFN 3 mm to 12 mm Multiple MEMS applications available
n MSOP to SO430 mil
n Single, dual, quad configuration
n Large variety of contactors
rƒsco so1000
Tube-to-Tube Gravity Handler

Specifications Tube Characteristics


Width of tube: 4.5 mm (min.); 18 mm (max.)
PLATFORM
Length of tube: 170 mm (min.); 540¹ mm (max.)
Performance Characteristics
Height of tube: 2.0 mm (min.); 7.2 mm (max.)
Throughput Standard Kits¹ : up to 14,400 uph 1 510 mm if rotary kits are used
Index Time (Belly Bar)²: down to 500 ms
Facility Requirements
Index Time (Real Plunge-To-Board) 3 : 800 ms
Bent Leads (±): 0.001 inch Nominal supply voltage¹ : 208 - 230 VAC
MTBF 4: 500 h Air pressure 2, 3 : 5 bar (72 psi) (min.); 9 bar (130 psi) (max.)
MTTR: 0.5 h Air consumption 4 : 300 l/min (max.)
MTBA 5: 30 min LN2 pressure: 1.1 bar (16 psi) (min); 6 bar (86 psi) (max.)
Uptime: 95% LN2 consumption: 10 l/hour
1
Quad asynchronous mode, e.g. 118 mil, depends on soaktime and device ¹ 1 x 16A, 50 - 60 Hz; 2 Kit dependent; 3 Minimum air pressure for rotary kits
dimensions; 2 Single mode, e.g. 150 mil/8 ld; 1.5 mm stroke; 3 Single mode, and devices ≥ 209 mil: 6 bar/68 psi; 4 Maximum consumption at hot and
e.g. QFN 5; 4 Includes any required scheduled maintenance; 5 Depends on cold operation if handler de-icing and heater pressure is adjusted according
tube capacity, test modes and test time to the manual

Jam Rates ESD Protection


Down to 1:10,000 (under controlled conditions) Field strength at device: 100 Volt (max.)
Temperature Characteristics Ground strap jack: 2 x 1 M-Ohm to ground
Device path: Conductive and grounded
Range: -60° to +160°C
Extended Version Range (optional): -60°C to +175°C Physical Dimensions
Soak Track Accuracy: ±2 °C Height: 1960 mm
Test Site Accuracy ¹ : ±2 °C Width 800 mm
Resolution: 0.1 °C Depth: 650 mm
Stabilization Time ²: 30 min Weight: 210 kg
Guard Band: down to ±0.1°C
Electrical Interface
Soak Capacity (standard kits): 2 x 555 mm
TTL parallel standard, RS 232 standard, IEEE 488 optional,
¹ Test site temperature accuracy can only be guaranteed with Rasco
approved sockets; 2 Ambient (25°C) to set point Network standard, USB at OPI standard

Device Specifications ¹
KITS
Body width (SO types): 118 mil (min.); 450 mil (max.)
Device Types
Body width (QFN types): 3.0 mm (min.); 12.0 mm (max.)
Body length: 3.0 mm (min.); 18.0 mm (max.) SO118 mil (min.); SO450 mil (max.)
Body height: 0.4 mm (min.); 3.0 mm (max.) QFN 3 x 3 mm (min.); 12 x 12 mm (max.)
Length/width ratio: 0.8 (min.) QFN thin down to 0.4 mm
PDIP 300 mil, 400 mil, 600 mil ¹
¹ For eSIP devices on request
CDIP on request ¹
Input / Output Characteristics¹ Conversion kits for other packages upon request
Input tube stack height²: 270 mm (max.) ¹ Device length 40 mm (max.)
Output tube stack height: 270 mm (max.)
Kit Changeover
Input tube stack capacity (MSOP): 34 tubes
Input capacity tuber loader 3 : 2720 devices 6 h typical
Output capacity tube unloader 3 : 2720 devices Contactors
RT specific: Input tube stack capacity (SO300): 12 tubes
Rasco high-performance contactors; third party contactor
¹ Data for SO and QFN devices, for eSIP, PDIP, and CDIP devices upon integration upon request
request; 2 45° stack; 3 for MSO 8 pin (80 devices/tube, 3 x 3 mm body)

12367 Crosthwaite Circle, Poway, CA 92064-6817


Tel. 858.848.8000 Email: [email protected]

For global sales locations and support, please visit


Specifications subject to change without notice.