10.6 Forms Gantry Girders
10.6 Forms Gantry Girders
e) Gantry girders supporting bumper shall be checked for bumper impact loads.
2) As per IS: 800-1984 (clause 3.9.3) the permissible stresses are to be increased
by 10% which considering the simultaneous effects of vertical and horizontal
surge loads for the combination given above.
3) As per IS: 800-1984 (clause 3.13.1) for Gantry Girders the limiting vertical
deflection under dead and imposed loads shall not exceed the following values:
a) For MOT cranes ............
L
b) For EOT cranes upto 500 kN ............. --
750
L
c) For EOT cranes over 500 kN .............. -1000
-
L
-
d) For charging car etc ........ 600
where, L = span of crane runaway girder (gantry girder)