Finepac Structures PVT - LTD: GAS Liquid (15000BPD) (Oil/Water)

The document provides specifications for two 3-phase separation cases with different water cut percentages. It details flow rates, viscosities, densities, pressures, temperatures, vessel positioning and dimensions, and carryover requirements for separating gas, oil and water streams.

Uploaded by

Dhanraj Vasanth
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
44 views

Finepac Structures PVT - LTD: GAS Liquid (15000BPD) (Oil/Water)

The document provides specifications for two 3-phase separation cases with different water cut percentages. It details flow rates, viscosities, densities, pressures, temperatures, vessel positioning and dimensions, and carryover requirements for separating gas, oil and water streams.

Uploaded by

Dhanraj Vasanth
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 2

FINEPAC ® STRUCTURES PVT.

LTD
REG.OFFICE & WORKS: - J-25, S Block MIDC, Bhosari, Pune 411026
W-54,T Block MIDC, Bhosari,Pune 411026
TELE No. :-( 020)6612061,27119517, TELE FAX :-( 020)27119512

Case- 3Phase (5% Water cut)


GAS LIQUID
(15000BPD)
( Oil/Water)
Flow rate (Kg/hr) (Max.) 168063 69825/4000
Viscosity(cp) 0.01 2.1/0.39
Density(Kg/m3) 125.9 800/985
Molecular Wt. 24.87 -
Liquid Surface Tension - 22.12/59.91
(mN/m)
% Of Droplet Want to
remove 100% of larger than 10micron size
Op. Pressure / Temp 91.7 @ 121C
(barg/ C) 99.3 @ 50 C
Max. allowed Pressure Min. Recommended
Drop
Vessel Position Horizontal (3 Phase)
Vertical/Horizontal
Vessel Dimension( If 48”Dia x 15 ft. L
available)
Required Water-in-Oil Guarantee 1% of volume
Carryover
Required Oil-in-Water -
Carryover
Required Gas-in-Oil Carry Shall be avoided
under

 Structured Packings & Column Internals For Chemical Distillation • Industrial Fabrication in SS, Copper, Special Metals
 Pusher Centrifuges for Solid-Liquid Separation • Random Packings & Trays (Bubble Cap, Valve) for Distillation
 Static Mixers • Internals for Oil & Gas Industry

www.finepacindia.in
FINEPAC ® STRUCTURES PVT.LTD
REG.OFFICE & WORKS: - J-25, S Block MIDC, Bhosari, Pune 411026
W-54,T Block MIDC, Bhosari,Pune 411026
TELE No. :-( 020)6612061,27119517, TELE FAX :-( 020)27119512

Case- 3Phase (85% Water cut)


GAS LIQUID
(15000BPD)
( Oil/Water)
Flow rate (Kg/hr) (Max.) 168063 11025/62475
Viscosity(cp) 0.01 2.1/0.39
Density(Kg/m3) 125.9 800/985
Molecular Wt. 24.87 -
Liquid Surface Tension - 22.12/59.91
(mN/m)
% Of Droplet Want to
remove 100% of larger than 10micron size
Op. Pressure / Temp 91.7 @ 121C
(barg/ C) 99.3 @ 50 C
Op. Temperature©
Max. allowed Pressure Min. Recommended
Drop
Vessel Position Horizontal (3 Phase)
Vertical/Horizontal
Vessel Dimension( If 48”Dia x 15 ft. L
available)
Required Water-in-Oil Guarantee 1% of volume
Carryover
Required Oil-in-Water -
Carryover
Required Gas-in-Oil Carry Shall be avoided
under

 Structured Packings & Column Internals For Chemical Distillation • Industrial Fabrication in SS, Copper, Special Metals
 Pusher Centrifuges for Solid-Liquid Separation • Random Packings & Trays (Bubble Cap, Valve) for Distillation
 Static Mixers • Internals for Oil & Gas Industry

www.finepacindia.in

You might also like