0% found this document useful (0 votes)
189 views

B1 FTB

The document shows reinforcement details for multiple structural elements including footings, beams, columns, and shear walls. It includes bar sizes, spacing, cover, and other notes. Specifically, it provides reinforcement details for four different sections labeled B1, B2, B3 including bar diameters, spacing, cover, and locations of stirrups for beams and columns. It also includes notes on yield strengths of reinforcement, requirements for splices and lap lengths.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
189 views

B1 FTB

The document shows reinforcement details for multiple structural elements including footings, beams, columns, and shear walls. It includes bar sizes, spacing, cover, and other notes. Specifically, it provides reinforcement details for four different sections labeled B1, B2, B3 including bar diameters, spacing, cover, and locations of stirrups for beams and columns. It also includes notes on yield strengths of reinforcement, requirements for splices and lap lengths.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

FTB B1

@SUPPORT @MIDSPAN @SUPPORT @MIDSPAN

200mm 200mm 200mm 200mm

3 - Ø16mm 2 - Ø16mm 6 - Ø16mm 2 - Ø16mm

5 - Ø16mm

Ø10mm

400mm

400mm
400mm

400mm
STIRRUPS

2 - Ø16mm 2 - Ø16mm 2 - Ø16mm 7 - Ø16mm

40mm CONCRETE COVER 40mm 40mm 40mm

B2 B3
@SUPPORT @MIDSPAN @SUPPORT @MIDSPAN

200mm 200mm 200mm 200mm

6 - Ø16mm 2 - Ø16mm 3 - Ø16mm 2 - Ø16mm

5 - Ø16mm

Ø10mm
400mm

400mm

400mm

400mm
STIRRUPS

2 - Ø16mm 7 - Ø16mm 2 - Ø16mm 2 - Ø16mm

40mm 40mm 40mm CONCRETE COVER 40mm

NOTES ON REINFORCEMENT
1. UNLESS OTHERWISE NOTED IN PLANS, THE YIELD STRENGTH OF REINFORCING BARS SHALL BE:
A. FOOTINGS, FOOTING BEAM AND GIRDERS -------------------------- fy = 414 MPa ( 60,000 psi)
B. COLUMNS AND SHEAR WALLS -------------------------------------------- fy = 414 MPa ( 60,000 psi)
C. BEAMS AND GIRDER ---------------------------------------------------------- fy = 414 MPa ( 60,000 psi)
D. NON-LOAD BEARING WALL PARTITIONS, BEDDED SLABS, FLOOR & ROOF SLABS,
PARAPETS, CATCH BASIN, SIDE WALK --------------------------- fy = 227.5 MPa ( 33,000 psi)
2. ALL REINFORCING BARS SIZE 10mm OR BIGGER SHALL BE DEFORMED IN ACCORDING WITH
ASTM A 706, BARS.
3. SPLICES SHALL BE SECURELY WIRED TOGETHER & SHALL LAP OR EXTEND IN ACCORDANCE
W/ TABLE A & TABLE B (TABLE OF LAP SPLICE & ANCHORAGE LENGTH) UNLESS OTHERWISE
SHOWN ON DRAWINGS, SPLICES SHALL BE STAGGERED WHENEVER POSSIBLE.

You might also like