Design of Slab
Design of Slab
Given:
live load: 4.8 kPa fc' = 28 mPa
fy = 420 mPa L: 4 m
floor finish: 1.1 kPa f = 0.9 cover = 20 mm
ceiling finish: 0.24 kPa f1 = 0.85
mech. duct allowance 0.25 kPa conc. unit wt.= 23.5 kN/m3
electrical load 0 kPa
partition load: 0.24 kPa using 12 mm rebars
miscellaneous load: 0.5 kPa Ad = 113.10 mm2
Solution:
minimum slab thickness, h
L ( 4 ) ( 1000 )
h= = = 143 mm
28 28
say h = 170 mm
Dead Loads:
slab self-weight = h x conc. unit wt.= ( 0.17 ) ( 23.5 ) = 4.00 kPa
floor finish = 1.1 kPa
ceiling finish = 0.24 kPa
mech. duct allowance = 0.25 kPa
electrical load = 0 kPa
partition load = 0.24 kPa
miscellaneous loads = 0.5 kPa
6.33 kPa
Factored Load:
WUDL= 1.2 (DL) = 1.6 ( 6.33 ) = 7.590 kPa
WULL= 1.6 (LL) = 1.6 ( 4.8 ) = 7.68 kPa
WU = WUDL + WULL = 15.270 kPa
At END 1 :
Wu L2 ( 15.27 ) ( 4 )2
Mu = = = 22.2109 kN-m
11 11
MU 22.211 x 10e6
Rn = = = 1.190 MPa
f b d12 0.90 x ### x (144 ) 2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 1.190
= x 1- 1- = 0.00291
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20 3
= x = 0.02064
420 7
As = f b d
= ( 0.00333 ) ( 1000 ) ( 144 )
= 480 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 235.625 mm
As 480
say S = 230 mm
At MIDSPAN :
Wu L2 ( 15.27 ) ( 4 )2
Mu = = = 15.2700 kN-m
16 16
MU 15.270 x 10e6
Rn = = = 0.818 MPa
f b d12 0.90 x ### x (144 ) 2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.818
= x 1- 1- = 0.00198
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
(0.85) b1 fc' 7
3
= x = 0.02064
420 7
As = f b d
= ( 0.00333 ) ( 1000 ) ( 144 )
= 480 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 235.625 mm
As 480
say S = 230 mm
At END 2 :
Wu L2 ( 15.27 ) ( 4 )2
Mu = = = 24.4320 kN-m
10 10
MU 24.432 x 10e6
Rn = = = 1.309 MPa
f b d12 0.90 x ### x (144 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 1.309
= x 1- 1- = 0.00321
420 0.85 x 28.0
(0.75)(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x = 0.02064
420 7
As = f b d1
= ( 0.00333 ) ( 1000 ) ( 144 )
= 480 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 235.625 mm
As 480
say S = 230 mm
temperature bars :
Ast = 0.0018 bh
= 0.0018 ( 1000 ) ( 170 )
= 306 mm2
Given:
short side A: 4.7 m fc' = 28 mPa
long side B: 4.7 m fy = 420 mPa
f = 0.9
LOADS: f = 0.85
live load: 4.8 kPa conc. unit wt.= 23.5 kN/m3
SOLUTION:
4.70
ratio m = = 1.000 > 0.500 Two-way Slab!
4.70
d1 = h - (cover) - (rebar f) = 84 mm
d2 = h - (cover) - (rebar f) - (half of rebar f) = 72 mm
Dead Loads:
slab self-weight = h x conc. unit wt.= ( 0.11 ) ( 23.5 ) = 2.59 kPa
floor finish = 1.1 kPa
ceiling finish = 0.24 kPa
mech. duct allowance = 0.25 kPa
electrical load = 0 kPa
partition load = 0.24 kPa
miscellaneous loads = 1 kPa
5.42 kPa
Factored Load:
WUDL = 1.2 (DL) = 1.2 ( 5.42 ) = 6.498 kPa
WULL = 1.6 (LL) = 1.6 ( 4.8 ) = 7.68 kPa
WU = WUDL + WULL = 14.178 kPa
at midspan
MADL = (WuDL) (CADL) (A2)
= 2.584 kN-m
MALL = (WuLL) (CALL) (A2)
= 4.581 kN-m
MA = MADL + MALL = 7.164 kN-m
at midspan
MBDL = (WuDL) (CBDL) (B2)
= 2.584 kN-m
MBLL = (WuLL) (CBLL) (B2)
= 4.581 kN-m
MB = MBDL + MBLL = 7.164 kN-m
Strength Design:
A. Short Span, Middle Strip
at continuous edge
MA 14.094 x 10e6
Rn = = = 2.219 MPa
f b d12 0.90 x ### x (84 ) 2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 2.219
= x 1- 1- = 0.00556
420 0.85 x 28.0
As = f b d1
= ( 0.00556 ) ( 1000 ) ( 84 )
= 466.750254 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 242.31374 mm
As 466.750254
say S = 240 mm
at midspan
MA 7.164 x 10e6
Rn = = = 1.128 MPa
f b d12 0.90 x ### x (84 ) 2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 1.128
= x 1- 1- = 0.00275
420 0.85 x 28.0
As = f b d1
= ( 0.00333 ) ( 1000 ) ( 84 )
= 280 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 403.92857 mm
As 280
say S = 400 mm
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 3.021
= x 1- 1- = 0.00772
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20 3
= x = 0.02064
420 7
As = f b d2
= ( 0.00772 ) ( 1000 ) ( 72 )
= 555.685403 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 203.53243 mm
As 555.685403
say S = 200 mm
at midspan
MB 7.164 x 10e6
Rn = = = 1.536 MPa
f b d22 0.90 x ### x (72 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 1.536
= x 1- 1- = 0.00378
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20 3
= x = 0.02064
420 7
As = f b d2
= ( 0.00378 ) ( 1000 ) ( 72 )
= 272.327693 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 415.30848 mm
As 272.327693
say S = 410 mm
Given:
short side A: 3.7 m fc' = 28 mPa
long side B: 4.7 m fy = 420 mPa
f = 0.9
mech. duct allowance
LOADS: f = 0.85
live load: 6 kPa conc. unit wt. = 23.5 kN/m3
mech. duct allowance
floor finish: 1.1 kPa CA = 0.057 using 12 mm rebars
mech. duct allowance
ceiling finish: 0.24 kPa CADL = 0.033 cover = 20 mm
electrical load 0.25 kPa CALL = 0.045
0 kPa CB = 0.049 Ad = 113.10
partition load: 0.24 kPa CBDL = 0.014
miscellaneous load: 1 kPa CBLL = 0.018 0
SOLUTION:
3.70
ratio m = = 0.787 > 0.500 Two-way Slab!
4.70
d1 = h - (cover) - (rebar f) = 74 mm
d2 = h - (cover) - (rebar f) - (half of rebar f) = 62 mm
Dead Loads:
slab self-weight = h x conc. unit wt.= ( 0.1 ) ( 23.5 ) = 2.35 kPa
floor finish = 1.1 kPa
ceiling finish = 0.24 kPa
mech. duct allowance = 0.25 kPa
electrical load = 0 kPa
partition load = 0.24 kPa
miscellaneous loads = 1 kPa
5.180 kPa
Factored Load:
WUDL = 1.2 (DL) = 1.2 ( 5.18 ) = 6.216 kPa
WULL = 1.6 (LL) = 1.6 ( 6 ) = 9.6 kPa
WU = WUDL + WULL = 15.816 kPa
Solving for Moments:
A. Short Span, Middle Strip
at continuous edge
0.80 0.055
0.787 CA
0.75 0.061
at midspan
for DL: 0.8 0.032
0.787 CADL
0.75 0.036
at midspan
for DL: 0.8 0.015
0.787 CBDL
0.75 0.013
Strength Design:
A. Short Span, Middle Strip
at continuous edge
MA 12.240 x 10e6
Rn = = = 2.484 MPa
f b d12 0.90 x ### x (74 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 2.484
= x 1- 1- = 0.00626
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20 3
= x = 0.02064
420 7
\
when rmin < r < rmax
Therefore, use 0.00626 for As
As = f b d1
= ( 0.00626 ) ( 1000 ) ( 74 )
= 463.172675 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 244.18539 mm
As 463.172675
say S = 240 mm
at midspan
MA 8.760 x 10e6
Rn = = = 1.778 MPa
f b d12 0.90 x ### x (74 ) 2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 1.778
= x 1- 1- = 0.00440
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20 3
= x = 0.02064
0 7
As = f b d1
= ( 0.00440 ) ( 1000 ) ( 74 )
= 325.846264 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 347.0962 mm
As 325.846264
say S = 340 mm
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 4.970
= x 1- 1- = 0.01342
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20 3
= x = 0.02064
420 7
As = f b d2
= ( 0.01342 ) ( 1000 ) ( 62 )
= 832.209691 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 135.90325 mm
As 832.209691
say S = 130 mm
Smax= 2h = 2 ( 100 ) = 200 mm or 450 mm
Therefore, Smax = 200 mm
at midspan
MB 5.856 x 10e6
Rn = = = 1.693 MPa
f b d22 0.90 x ### x (62 ) 2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 1.693
= x 1- 1- = 0.00418
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20 3
= x = 0.02064
420 7
As = f b d2
= ( 0.00418 ) ( 1000 ) ( 62 )
= 259.467596 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 435.89258 mm
As 259.467596
say S = 430 mm
ONE-WAY SLAB
GUIDELINES:
1. Fill-up only colored cells with their corresponding values.
slab length
concrete stress and strain
type of loading
miscellaneous dead loads
rebars diameter and concrete cover
constants for computing h and Mu.
2. Avoid editing non-colored cells for it may cause unreasonable design.
3. For the design of sections having different moments, just replace tha value of
denominator for Mu for that corresponding section.
4. Checking computations using calculator may will not match with the computer's
computations due to rounding-off numbers. Computer uses complete decimal
numbers and exact values.
-WAY SLAB 2s8 case 2
RESULTING TABLE
GUIDELINES:
1. Fill-up only colored cells with their corresponding values.
slab dimensions
concrete stress and strain
type of loading
miscellaneous dead loads
rebars diameter and concrete cover
constants from the table of values
2. Avoid editing non-colored cells for it may cause unreasonable design.
3. Give the exact dimensions of the slab. Don't forget to subtract the supporting
beam dimensions.
4. Checking computations using calculator may will not match with the computer's
computations due to rounding-off numbers. Computer uses complete decimal
numbers and exact values.
5. Having discontinuous edge will depend upon the case of the slab.
As seen on the table, depends on slab's case.
-WAY SLAB 2s9 case 8
TERPOLATION
RESULTING TABLE
GUIDELINES:
1. Fill-up only colored cells with their corresponding values.
slab dimensions
concrete stress and strain
type of loading
miscellaneous dead loads
rebars diameter and concrete cover
constants from the table of values
2. Avoid editing non-colored cells for it may cause unreasonable design.
3. Give the exact dimensions of the slab. Don't forget to subtract the supporting
beam dimensions.
4. Checking computations using calculator may will not match with the computer's
computations due to rounding-off numbers. Computer uses complete decimal
numbers and exact values.
5. Having discontinuous edge will depend upon the case of the slab.
As seen on the table, depends on slab's case.
v
SEISMIC ANALYSIS
CV I
V= W
RT
where:
I= 1.00 (For Special Occupancy Structure)
R= 8.50 (For Moment Resisting Frames)
W= 23485.07 KN (Total Weight of the Building)
CV = 0.64
T = Ct (hn)
3/4
where:
Ct = 0.0731 (For Reinforced Concrete, Moment Resisting Frames)
hn = 12.4 (Total Height of the Buiding)
So, T = ( 0.0731) ( 12.4 )3/4
= 0.4830406063 s
( 0.64) ( 1.00 )
Therefore, V = ( 23,485.07 )
( 8.5) ( 0.48304)
= 3660.743 KN
Total 123181.52
where : Wxhx
Fx = n ( V - ft ) *Since T < 0.70s, then ft = 0
f wihi
i=1
Distribution of Forces to Frames
Transversal
R Direct
Frame Rel. R d d2 Rd2
fR Force, D
1 4 0.2 0.2 16 256 1024
3 4 0.2 0.2 0 0 0
6 0 0 0 0 0 0
7 0 0 0 0 0 0
8 0 0 0 0 0 0
9 0 0 0 0 0 0
10 0 0 0 0 0 0
Total 20 2560
where : Mt Rd2
T = x also Mt = (0.05) (Frame Length) (1)
d fRd2 = (0.05) ( 24 ) (1) =
3 4 0.2 0.2 0 0 0
6 0 0 0 0 0 0
7 0 0 0 0 0 0
8 0 0 0 0 0 0
9 0 0 0 0 0 0
10 0 0 0 0 0 0
Total 20 1440
where : Mt Rd2
T = x also Mt = (0.05) (Frame Length) (1)
2
d fRd = (0.05) ( 32 ) (1) =
C ANALYSIS
Note: Fill-up only yellow cells.
23.5 2133.030 kN
23.5 44.063 kN
23.5 40.808 kN
23.5 30.538 kN
23.5 0.000 kN
TOTAL 2248.439 kN
23.5 451.200 kN
23.5 338.400 kN
23.5 188.000 kN
23.5 282.000 kN
23.5 0.000 kN
23.5 0.000 kN
23.5 0.000 kN
TOTAL 1259.600 kN
23.5 789.600 kN
23.5 651.420 kN
23.5 0.000 kN
TOTAL 1441.020 kN
23.5 60.454 kN
23.5 43.181 kN
TOTAL 103.635 kN
23.5 2133.030 kN
23.5 44.063 kN
23.5 40.808 kN
23.5 30.538 kN
23.5 0.000 kN
TOTAL 2248.439 kN
23.5 1443.840 kN
23.5 1082.880 kN
23.5 210.560 kN
23.5 270.720 kN
23.5 360.960 kN
23.5 0.000 kN
23.5 0.000 kN
TOTAL 3368.960 kN
23.5 789.600 kN
23.5 651.420 kN
23.5 0.000 kN
TOTAL 1441.020 kN
23.5 230.300 kN
23.5 0.000 kN
TOTAL 230.300 kN
23.5 2133.030 kN
23.5 44.063 kN
23.5 40.808 kN
23.5 30.538 kN
23.5 0.000 kN
TOTAL 2248.439 kN
23.5 1443.840 kN
23.5 1082.880 kN
23.5 210.560 kN
23.5 270.720 kN
23.5 360.960 kN
23.5 0.000 kN
23.5 0.000 kN
TOTAL 3368.960 kN
23.5 789.600 kN
23.5 651.420 kN
23.5 0.000 kN
TOTAL 1441.020 kN
23.5 230.300 kN
23.5 0.000 kN
TOTAL 230.300 kN
23.5 1443.840 kN
23.5 1082.880 kN
23.5 105.280 kN
23.5 270.720 kN
23.5 721.920 kN
23.5 0.000 kN
23.5 0.000 kN
TOTAL 3624.640 kN
23.5 230.300 kN
23.5 0.000 kN
TOTAL 230.300 kN
TOTAL : 23485.072 kN
BASE SHEAR, V
0 #DIV/0! #DIV/0!
0 #DIV/0! #DIV/0!
0 #DIV/0! #DIV/0!
0 #DIV/0! #DIV/0!
0 #DIV/0! #DIV/0!
0 #DIV/0! #DIV/0!
0 #DIV/0! #DIV/0!
0 #DIV/0! #DIV/0!
0 #DIV/0! #DIV/0!
0 #DIV/0! #DIV/0!
0 #DIV/0! #DIV/0!
0 #DIV/0! #DIV/0!
) (Frame Length) (1)
1.60
PORTAL ANALYSIS
Span Length 1 : 2.50 m Column Height 3 : 3.00 m Note : This is designed for 7-span frame. In case of
Span Length 2 : 2.50 m Column Height 2 : 3.00 m lesser span, the second to the last column
Span Length 3 : 3.00 m Column Height 1 : 3.00 m frame and upper is not included. Just look
Span Length 4 : 2.00 m at the horizontal force, if there is negative,
Span Length 5 : 4.00 m that column frame is not included.
Span Length 6 : 2.00 m No. of Spans : 6
43.82 43.82 0.00 43.82 7.30 36.52 -18.26 54.78 27.39 27.39
178.35 134.53 0.00 134.53 22.42 112.10 -56.05 168.16 84.08 84.08
385.80 207.45 0.00 207.45 34.58 172.88 -86.44 259.32 129.66 129.66
73.04 36.52
73.04 36.52
27.39 0.00
117.20 195.34
39.07
84.08 0.00
151.17 75.59
151.17 75.59
84.08 0.00
65.12 108.53
21.71
129.66 0.00
194.59 97.29
194.59 97.29
129.66 0.00
#REF!
#REF!
#REF!
54.78 113.38
0.00 54.78
113.38
0.00 113.38
145.94
0.00 145.94
DESIGN OF BEAM
Note : Fill-up yellow cells only.
Given:
Wu = 67.93 kN d' =0 mm
fc' = 28 MPa
fy = 420 MPa
f = 0.9
b1 = 0.85 d= 540 mm
Es = 200000 MPa
d= 540 mm
b= 300 mm
d' = 0 mm
L= 6 m b = 300 mm
cover : 40 mm
using 10 mm f stirrups
Wu = 67.927 kN
L=6 m
245.115 Vu at d distance
Shear Diagram in KN
d= 0.54 m
-230.314
187.874 kN-m
Moment Diagram
AT END 1 :
Mu 254.436
Mn = = = 282.706667 kN-m
f 0.9
As = rmax b d
= ( 0.02064 ) ( 300 ) ( 540 )
= 3344.142857 mm2
1 r fy
Mu = r fy f b d2 1- x
1.7 fc'
1 ( 0.02064 ) ( 420 )
= ( 0.0206 ) ( 420 ) ( 0.9 ) ( 300 ) ( 540 )2 1 - x
1.7 28
= 558274553 MN-mm
Mu = 558.2745527 kN-m
Mu 558.27455271
Mn = = = 620.305059 kN-m
f 0.9
620.3050586 > 282.70666667 Therefore, it's a single reinforcement only!
AT END 1
Mn1 = 620.3050586 kN-m IF DOUBLY-REINFORCED BEAM
As1 = 3344.142857 mm2 IF SINGLY REINFORCED BEAM
Mn2 = 282.706666667 - 620.305059
= -337.598391905 kN-m Mu = f Rn b d²
254 = 0.9 Rn ( 300 ) (
From Mn2 = As2 fy ( d - d' ) 3.231672 Mpa
Mn2 -337.5984 x10e6
As2 = = ρ= 0.85 1 - 1- 2 Rn
fy ( d -d' ) 420 ( 540 - 0 ) fy 0.85 fc
= -1488.52906484 mm2
ρ= 0.85 28 1-
Check if compression steel yields, when Ey < Es' : 420
where:
fy 420
Ey = = = 0.00210 ρ= 0.0083027
Es 200000
AT MIDSPAN :
Mu 187.874
Mn = = = 208.748889 kN-m
f 0.9
As = rmax b d
= ( 0.02064 ) ( 300 ) ( 540 )
= 3344.142857 mm2
1 r fy
Mu = f fy f b d2 1- x
1.7 fc'
1 ( 0.02064 ) ( 420 )
= ( 0.0206 ) ( 420 ) ( 0.9 ) ( 300 ) ( 540 )2 1 - x
1.7 28
= 558274553 MN-mm
Mu = 558.2745527 kN-m
Mu 558.27455271
Mn = = = 620.305059 kN-m
f 0.9
620.3050586 > 208.74888889 Therefore, it's a single reinforcement only!
As = f b d1
IF COMPRESSION STEEL YIELDS: IF COMPRESSION STEEL DOESN'T YIELDS: = ( 0.00600 ) ( 300)
Es' 0.00300 = 971.852802 mm2
fs' = fy = 420 MPa fs' = ( fy ) = ( 420 )
Ey 0.00210
As' = As2 = 600 MPa minimum edge distance =
= -1814.62156 mm2 =
Mn2 -411.56x10e6 =
As' = =
fs' ( d - d' ) 600.00 ( 540 - 0 )
= -1270.2351 mm2 For tension reinforcement:
using 20 mm f bars
As
Therefore, COMPRESSION STEEL YIELDS N=
As' = -1814.6215594 mm2 Ad
AT END 2 :
Mu -202.845
Mn = = = -225.38333 kN-m
f 0.9
As = rmax b d
= ( 0.02064 ) ( 300 ) ( 540 )
= 3344.142857 mm2
1 r fy
Mu = f fy f b d2 1- x
1.7 fc'
1 ( 0.02064 ) ( 420 )
= ( 0.0206 ) ( 420 ) ( 0.9 ) ( 300 ) ( 540 )2 1 - x
1.7 28
= 558274553 MN-mm
Mu = 558.2745527 kN-m
Mu 558.27455271
Mn = = = 620.305059 kN-m
f 0.9
620.3050586 > -225.38333333 Therefore, it's a single reinforcement only!
As = f b d1
IF COMPRESSION STEEL YIELDS: IF COMPRESSION STEEL DOESN'T YIELDS: = ( 0.00333 ) ( 300)
Es' 0.00300 = -945.1033308 mm2
fs' = fy = 420 MPa fs' = ( fy ) = ( 420 )
Ey 0.00210
As' = As2 = 600 MPa minimum edge distance =
= -3728.7848 mm2 =
Mn2 -845.69x10e6 =
As' = =
fs' ( d - d' ) 600.00 ( 540 - 0 )
= -2610.1494 mm2 For tension reinforcement:
using 28 mm f bars
As
Therefore, COMPRESSION STEEL YIELDS N=
As' = -3728.7847968 mm2 Ad
Vu = 245.115 kN
Vud = Vu - Wu d
= 245.115 - ( 67.927 ) ( 0.54 )
= 208.43442 kN
= 208434.42 N
1
Vc = fc' bw d
6
1
= 28 ( 300 ) ( 540 )
6
= 142,870.571 N
f Vc 0.85 ( 142,870.571 )
= = 53576.4641 N
2 2
f Vc
Vud > Therefore, the beam needs web reinforcement!
2
f
Av = 2 4 ( 10 )2 = 157.079633 mm2
d = 540mm
Vud = 208,434 N
f Vs
Vu = 245,115 N
f Vs = 121,440 N
1/2 fVc = 53,576 N
x= 2.82 m
stirrups needed here
245,115 N - 67,927 x = 53,576
x= 2.82 m
to provide the needed spacing based from other values of V u to minimize stirrups,
At x = 1 m
Vu = 245,115 - 67,927 ( 1 )
= 177,188 N
Vu
Vs = - Vc
f
177,188
= - 142,870.571
0.85
= 93380.0956667 N
A v fy d
s=
Vs
( 157.08 ) ( 420 ) ( 540 )
= = 381.51236 mm say 380 mm
93380.095667
At x = 1.5 m
Vu = 245,115 - 67,927 ( 1.5 )
= 143,225 N
Vu
Vs = - Vc
f
143,225
= - 142,870.571
0.85
= 48096.0956667 N
Av fy d
s=
Vs
( 157.08 ) ( 420 ) ( 540 )
= = 740.718351 mm say 740 mm
48096.0956666667
OPTIONAL SECTION
At x = 2 m
Vu = 245,115 - 67,927 ( 2 )
= 109,261 N
Vu
Vs = - Vc
f
109,261
= - 142,870.571
0.85
= -14328.2180588 N
Av fy d
s=
Vs
( 157.08 ) ( 420 ) ( 540 )
= = -2486.3986 mm say -2490 mm
-14328.2180588235
At x = 2.5 m
Vu = 245,115 - 67,927 ( 2.5 )
= 75,298 N
Vu
Vs = - Vc
f
75,298
= - 142,870.571
0.85
= -54284.6886471 N
Av fy d
s=
Vs
( 157.08 ) ( 420 ) ( 540 )
= = -656.27457 mm say -660 mm
-54284.6886470588
At x = 3 m
Vu = 245,115 - 67,927 ( 3 )
= 41,334 N
Vu
Vs = - Vc
f
41,334
= - 142,870.571
0.85
= -94242.3357059 N
Av fy d
s=
Vs
( 157.08 ) ( 420 ) ( 540 )
= = -378.02184 mm say -380 mm
-94242.3357058824
At x = 3.5 m
Vu = 245,115 - 67,927 ( 3.5 )
= 7,371 N
Vu
Vs = - Vc
f
7,371
= - 142,870.571
0.85
= -134198.806294 N
Av fy d
s=
Vs
( 157.08 ) ( 420 ) ( 540 )
= = -265.46928 mm say -270 mm
-134198.806294118
@ 260 mm spacing
540 - 50 = 490 mm
490 mm
= 1.885 say 2 pcs
260 mm
1- 2( 3.23167 )
0.85 (28)
28
or
4 x 420
Therefore, use 0.00333
7
3
= 0.02064
7
rmax
Ad = 314.15926
1345.0384671
= 4.281 say 5 pcs.
314.15926 arrangement: 5 bars horizontally
300 - 2( 40 ) - 2( 10 ) - 5( 20 )
= 25 mm > 25 mm OK!
)( 540 )²
0.85 fc
1- 2( 2.3862470152 )
0.85 (28)
1.4 28
or
420 4 x 420
0.0031497039 Therefore, use 0.00333
7
7
x = 0.02064
7
< rmax
for As
( 540 )
mm f bars Ad = 314.15926
971.85280205
= = 3.094 say 4 pcs.
314.15926 arrangement: 3 bars horizontally
300 - 2( 40 ) - 2( 10 ) - 3( 20 )
= 70 mm > 25 mm OK!
)( 540 )²
0.85 fc
1- 2( -2.5763984149 )
0.85 (28)
1.4 28
or
420 4 x 420
0.0031497039 Therefore, use 0.00333
7
3
x = 0.02064
7
< rmax
for As
( 540 )
mm f bars Ad = 615.7521496
-945.10333085
= = -1.535 say -1 pcs.
615.7521496 arrangement: 6 bars horizontally
300 - 2( 40 ) - 2( 10 ) - 6( 28 )
= 6.4 mm < 28 mm NOT OK!
COLUMN DESIGN
Pu = 5943.8164 kN
Given:
Pu = 5943.8164 kN where As
fc' = 28 MPa r= ; As = r Ag
fy = 420 MPa Ag
initial r = 0.05
f= 0.65
Solution:
checking r :
rgmin = 1% of Ag = 0.01
rgmax = 8% of Ag = 0.08
As 8143.00816
r= = = 0.051
Ag 160000
rgmin < r < rgmax OK for rho min! Also, OK! for rho max
Design of ties:
( a ) 16 db = 16 ( 36 ) = 576 mm
( b ) 48 dt = 48 ( 12 ) = 576 mm
( c ) least lateral column dimension = 400 mm
UMN
Ag ) ]
mum req'd rebars
FOUNDATION DESIGN
Given:
DL = 13.44 kN/m a= 0.2 m
LL = 0 kN/m depth of footing = 1500 mm
fc' = 28 MPa
fy = 420 MPa cover = 75 mm
f = 0.9 0.75
qa = 200 kN/m2
conc weight = 23.5 kN/m3
soil weight = 16 kN/m3 LL
DL
a
Ground Line
1500mm
500mm
1m
Solution:
500 1000
= 200 - ( 23.5 ) - ( 16 )
1000 1000
= 172.25 kN/m2
DL + LL
width required ( l ) =
qe
13.44 + 0
=
172.25
= 0.078 m say 1 m
1.2 DL + 1.6 LL
qu =
width required
= 16.128 kN/m2
l - a
Vu = - d ( qu )
2
1 - 0.0002
= - 0.425 ( 16.128 )
2
= 1.2079872 kN
6 Vu
d=
f fc' ( bw )
6 ( 1.208 ) (10 )3
=
( 0.75 ) 28 ( 1000 )
l - a 1 - 0.0002
cantilever length = = = 0.5 m
2 2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.012
= x 1- 1- = 0.00003
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
(0.85)( 0.85) ( 28) 3
= x = 0.02064
420 7
As = f b d
= ( 0.00333 ) ( 1000 ) ( 425 )
= 1416.667 mm2
say S = 220 mm
Given:
DL = 3449 kN a = 600 m
LL = 1189 kN depth of footing = 1500 mm
fc' = 28 MPa
fy = 420 MPa cover = 80 m
f = 0.9 0.75
fs = 40
qa = 200 kN/m 2
400 mm
400 mm
Ground Line
1500mm
900mm
5.5 m
Solution:
900 600
= 200 - ( 23.5 ) - ( 16 )
1000 1000
= 169.25 kN/m2
DL + LL
Af required =
qe
3448.53 + 1189
=
169.25
= 27.3991 m2
1.2 DL + 1.6 LL
qu =
Af
= 199.678 kN/m2
5.5 m
A1
1.63 m d = 820 mm
2.45 m
Vu1 = qu ( A1 )
= 1790.114 kN
6 Vu1
d=
f fc' ( bw )
6 ( 1,790.114 ) (10 )3
=
( 0.75 ) 28 ( 5500 )
A2
d/2
a
600 + 820 =
d/2
bo = 4 ( 1420 ) = 5680 mm
Vu2 = qu ( A2 )
= 5637.630 kN
3 Vu2
d=
f fc' ( bo )
3 ( 5,637.630 ) ( 10 )3
=
0.75 28 ( 5680 )
12 Vu2
d=
fs d
f +2 fc' ( bo )
bo
12 ( 5,637.630 ) ( 10 )3
=
( 40 ) d
0.75 28 ( 5680 )
5680 + 2
where a = 158.745078664 d2
b = 45083.6023405 d
c = -67651555.45
-b f b2 - 4ac
d=
2a
d= 526.0783949 mm or -810.078395 mm
l - a 5.5 - 0.6
cantilever length = = = 2.45 m
2 2
Mu 3,296.060 x 10e6
Rn = = = 0.990 MPa
fbd 1
2
0.90 x 5500 x (820 )
2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.990
= x 1- 1- = 0.00241
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
(0.85)( 0.85) ( 28) 3
= x = 0.02064
420 7
As = f b d
= ( 0.00333 ) ( 5500 ) ( 820 )
= 15033.333 mm2
using 25 mm bars ; Ad = 490.87
say S = 30 mm
N
Note : Fill-up yellow cells only.
NG
( wall thickness )
425mm
0.00003
0.00333
0.02064
OOTING
( column dimension )
820mm
600 + 820 = 1420 mm
0.00241
0.00333
0.02064