0% found this document useful (0 votes)
352 views

Omicron

The 4-day training course teaches participants how to efficiently test overcurrent, distance, and transformer differential relays from scratch using the Omicron Test Universe. The course covers performing commissioning, troubleshooting, and periodic tests; testing the relay functions hands-on; and creating customized automated test plans and reports. Participants will learn configuration, flexible test plan creation, and hands-on testing for each relay type. The training is intended for technical staff involved in protection testing.

Uploaded by

Tufail Alam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
352 views

Omicron

The 4-day training course teaches participants how to efficiently test overcurrent, distance, and transformer differential relays from scratch using the Omicron Test Universe. The course covers performing commissioning, troubleshooting, and periodic tests; testing the relay functions hands-on; and creating customized automated test plans and reports. Participants will learn configuration, flexible test plan creation, and hands-on testing for each relay type. The training is intended for technical staff involved in protection testing.

Uploaded by

Tufail Alam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Power System Protection Testing

with the OMICRON Test Universe


Summary: Learn how to efficiently test overcurrent, distance and transformer differential relays from scratch
with the OMICRON Test Universe. Get familiar with the test procedure in hands-on and
theoretical sessions.
Prerequisites: Basic knowledge of power system protection
Duration: 4 days Language: English Code: C.0047.AAH

Objectives
> Performing commissioning, trouble-shooting and periodic tests of protection relays
> Testing overcurrent, distance and transformer differential relays with the OMICRON Test Universe
> Creating and modifying automated test plans and customized test reports
> Using the OMICRON Test Universe from scratch

Content
> Quick current and voltage output for easy wiring tests
> Configuration of the test object parameters and the test hardware
> Creating test plans which adapt automatically to newly entered relay settings
> Creating a flexible test plan for overcurrent relays including testing pick-up values and trip times
> Hands-on testing of the overcurrent protection function
> Creating a flexible test plan for distance relays including testing the trip times and zone reaches as well as
switch on to fault (manual close) and auto-reclosing
> Hands-on testing of distance relays
> Creating a flexible test plan for transformer differential relays including testing the stability during external faults,
the tripping characteristic, the trip times and the harmonic restraints
> Hands-on testing of transformer differential relays

Products
> Control Center, QuickCMC, Ramping, Pulse Ramping, Overcurrent, Advanced Distance, State Sequencer,
Autoreclosure, Advanced Differential
> CMC-Family

Audience
Technical staff from electric utilities, service companies and manufacturers involved in protection testing