0% found this document useful (0 votes)
97 views

Product Data Sheet: Tesys Gv2 - Motor Circuit Breaker - Thermal-Magnetic - 0.63 1 A

This document provides product data and specifications for the TeSys GV2 Motor circuit breaker with thermal-magnetic trip unit. It is rated for 0.63-1A, has 3 poles, is for AC motor protection, and mounts on a 35mm DIN rail or panel. It has thermal and magnetic tripping, a rotary control knob, and screw terminal connections for 1-6mm2 wire.

Uploaded by

Nguyen Chuyen
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
97 views

Product Data Sheet: Tesys Gv2 - Motor Circuit Breaker - Thermal-Magnetic - 0.63 1 A

This document provides product data and specifications for the TeSys GV2 Motor circuit breaker with thermal-magnetic trip unit. It is rated for 0.63-1A, has 3 poles, is for AC motor protection, and mounts on a 35mm DIN rail or panel. It has thermal and magnetic tripping, a rotary control knob, and screw terminal connections for 1-6mm2 wire.

Uploaded by

Nguyen Chuyen
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

Product data sheet GV2P05

Characteristics TeSys GV2 - Motor circuit breaker - thermal-


magnetic - 0.63…1 A

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Main
Range TeSys
Product name TeSys GV2
Device short name GV2P
Device application Motor
Trip unit technology Thermal-magnetic

Complementary
Poles description 3P
Network type AC
Utilisation category AC-3 conforming to IEC 60947-4-1
Category A conforming to IEC 60947-2
Network frequency 50/60 Hz conforming to IEC 60947-4-1
Fixing mode Clipped on 35 mm symmetrical DIN rail
Screwed on panel (with 2 x M4 screws)
Operating position Any position
Motor power kW 0.25 kW at 400/415 V AC 50/60 Hz
0.55 kW at 690 V AC 50/60 Hz
Breaking capacity 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
breaking capacity 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Control type Rotary knob
[In] rated current 1A
Thermal protection adjustment range 0.63...1 A
Magnetic tripping current 13 A
May 8, 2019
1
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ith] conventional free air thermal 1 A conforming to IEC 60947-4-1
current
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
Power dissipation per pole 2.5 W
Mechanical durability 100000 cycles
Electrical durability 100000 cycles for AC-3 at 440 V
Operating rate 25 cyc/h
Rated duty Continuous conforming to IEC 60947-4-1
Connections - terminals Screw clamp terminals 2 cable(s) 1...6 mm² solid
Screw clamp terminals 2 cable(s) 1.5...6 mm² flexible without cable end
Screw clamp terminals 2 cable(s) 1...4 mm² flexible with cable end
Tightening torque 1.7 N.m on screw clamp terminals
Suitability for isolation Yes conforming to IEC 60947-1
Phase failure sensitivity Yes conforming to IEC 60947-4-1
Height 89 mm
Width 45 mm
Depth 97 mm

Environment
Standards EN 60204
IEC 60947-1
IEC 60947-2
IEC 60947-4-1
NF C 63-120
NF C 63-650
NF C 79-130
UL 508
VDE 0113
VDE 0660
CSA C22.2
Product certifications ATEX
BV
CCC
CSA
DNV
EZU
GL
LROS (Lloyds register of shipping)
RINA
TSE
UL
UL 508 type E
EAC
Protective treatment TH
IP degree of protection IP20 conforming to IEC 60529
IK degree of protection IK04
Ambient air temperature for operation -20...60 °C
Ambient air temperature for storage -40...80 °C
Fire resistance 960 °C conforming to IEC 60695-2-1
Operating altitude 2000 m

Offer Sustainability
Sustainable offer status Green Premium product
RoHS (date code: YYWW) Compliant  - since  0631  -  Schneider Electric declaration of conformity
Schneider Electric declaration of conformity
REACh Reference contains SVHC above the threshold  -  Go to CaP for more details
Go to CaP for more details
Product environmental profile Available

2
Product Environmental Profile
Product end of life instructions Need no specific recycling operations

Contractual warranty
Warranty period 18 months

3
Product data sheet GV2P05
Performance Curves

Thermal-Magnetic Tripping Curves for GV2ME and GV2P


Average Operating Times at 20 °C Related to Multiples of the Setting Current

1 3 poles from cold state


2 2 poles from cold state
3 3 poles from hot state

Current Limitation on Short-Circuit for GV2ME and GV2P (3-Phase 400/415 V))
Dynamic Stress
I peak = f (prospective Isc) at 1.05 Ue = 435 V

4
1 Maximum peak current
2 24-32 A
3 20-25 A
4 17-23 A
5 13-18 A
6 9-14 A
7 6-10 A
8 4-6.3 A
9 2.5-4 A
10 1.6-2.5 A
11 1-1.6 A
12 Limit of rated ultimate breaking capacity on short-circuit of GV2ME (14, 18, 23, and 25 A ratings).

Thermal Limit on Short-Circuit for GV2P


2
Thermal Limit in kA s in the Magnetic Operating Zone
2
Sum of I dt = f (prospective Isc) at 1.05 Ue = 435 V

5
1 24-32 A
2 20-25 A
3 17-23 A
4 13-18 A
5 9-14 A
6 6-10 A
7 4-6.3 A
8 2.5-4 A
9 1.6-2.5 A
10 1-1.6 A

6
Product data sheet GV2P05
Dimensions Drawings

GV2P
On rail AM1 DE200, ED200 (35 x 15)

Panel mounted

On pre-slotted plate AM1 PA

Adapter plate GK2AF01

Combination GV2P + TeSys d contactor

GV2P + LC1D09…D18 LC1D25 and D32

b 176.4 186.8

c1 100.1 106.4

7
GV2P + LC1D09…D18 LC1D25 and D32

c 105.6 111.9

d1 95 95

d 100.5 100.5

Mounting
Mounting of External Operator GV2APN01, GV2APN02 or GV2APN04 for Motor Circuit Breakers GV2P

Door cut-out

(1) For IP65 only.


Mounting of External Operator GVAPH02 for Motor Circuit Breakers GV2P

a b

Minimum Maximum Minimum Maximum

GV2APN●● 140 250 – –

GV2APN●● + GVAPH02 – – 151 250

GV2APN●● + GVAPK11 250 434 – –

GV2APN●● + GVAPH02 + GVAPK11 – – 250 445

Door cut-out

(1) For IP65 only.

8
Product data sheet GV2P05
Connections and Schema

GV2P••

You might also like