Cisco Networking Academy Program


CCNP 3: Multilayer Switching
Companion Guide
Second Edition

Wayne Lewis, Ph.D.


Cisco Networking Academy Program

Cisco Press
800 East 96th Street
Indianapolis, Indiana 46240 USA
www.ciscopress.com
1439_CCNP_3.book Page ii Wednesday, October 27, 2004 9:54 AM

ii

Cisco Networking Academy Program


CCNP 3: Multilayer Switching Companion Guide
Second Edition
Cisco Systems, Inc.
Cisco Networking Academy Program
Copyright © 2005 Cisco Systems, Inc.
Published by:
Cisco Press
800 East 96th Street
Indianapolis, Indiana 46240 USA
All rights reserved. No part of this book may be reproduced or transmitted in any form or by any means, electronic
or mechanical, including photocopying and recording, or by any information storage and retrieval system, without
written permission from the publisher, except for the inclusion of brief quotations in a review.
Printed in the United States of America 1 2 3 4 5 6 7 8 9 0
Library of Congress Cataloging-in-Publication Number: 2003114385
ISBN: 1-58713-143-9

Trademark Acknowledgments
All terms mentioned in this book that are known to be trademarks or service marks have been appropriately capital-
ized. Cisco Press or Cisco Systems, Inc. cannot attest to the accuracy of this information. Use of a term in this book
should not be regarded as affecting the validity of any trademark or service mark.

Warning and Disclaimer


This book is designed to provide information about the Cisco Networking Academy Program CCNP 3: Multilayer
Switching course. Every effort has been made to make this book as complete and accurate as possible, but no
warranty or fitness is implied.
The information is provided on an “as is” basis. The author, Cisco Press, and Cisco Systems, Inc. shall have neither
liability nor responsibility to any person or entity with respect to any loss or damages arising from the information
contained in this book or from the use of the disks or programs that might accompany it.
The opinions expressed in this book belong to the author and are not necessarily those of Cisco Systems, Inc.

This book is part of the Cisco Networking Academy® Program series from Cisco Press. The
products in this series support and complement the Cisco Networking Academy Program
curriculum. If you are using this book outside the Networking Academy program, then you are
not preparing with a Cisco trained and authorized Networking Academy provider.

For information on the Cisco Networking Academy Program or to locate a Networking Academy,
please visit www.cisco.com/edu.

Corporate and Government Sales


Cisco Press offers excellent discounts on this book when ordered in quantity for bulk purchases or special sales.
For more information please contact:
U.S. Corporate and Government Sales 1-800-382-3419 [email protected]
For sales outside the United States please contact:
International Sales [email protected]
1439_CCNP_3.book Page iii Wednesday, October 27, 2004 9:54 AM

iii

Feedback Information
At Cisco Press, our goal is to create in-depth technical books of the highest quality and value. Each book is crafted
with care and precision, undergoing rigorous development that involves the unique expertise of members of the pro-
fessional technical community.
Reader feedback is a natural continuation of this process. If you have any comments on how we could improve
the quality of this book, or otherwise alter it to better suit your needs, you can contact us through e-mail at
[email protected]. Please be sure to include the book title and ISBN in your message.
We greatly appreciate your assistance.
Publisher John Wait
Editor-in-Chief John Kane
Executive Editor Mary Beth Ray
Cisco Representative Anthony Wolfenden
Cisco Press Program Manager Nannette M. Noble
Production Manager Patrick Kanouse
Senior Development Editor Christopher Cleveland
Project Editor Marc Fowler
Copy Editor Gayle Johnson
Technical Editors Mark Gallo, Stanford M. Wong, Jim Yoshida
Book/Cover Designer Louisa Adair
Compositor Octal Publishing, Inc.
Indexer Larry Sweazy
1439_CCNP_3.book Page iv Wednesday, October 27, 2004 9:54 AM

iv

About the Author


Wayne Lewis is the Cisco Academy manager for the Pacific Center for Advanced Technol-
ogy Training, based at Honolulu Community College. Since 1998, he has taught routing and
switching, remote access, troubleshooting, network security, and wireless networking to
instructors from universities, colleges, and high schools in Australia, Canada, Central Amer-
ica, China, Hong Kong, Indonesia, Japan, Mexico, Singapore, South America, Taiwan, and
the United States, both onsite and at Honolulu Community College. Before teaching com-
puter networking, Wayne began teaching math at age 20 at Wichita State University, followed
by the University of Hawaii and Honolulu Community College. He received a Ph.D. in math
from the University of Hawaii in 1992. He works as a contractor for Cisco Systems, develop-
ing curriculum for the Cisco Networking Academy Program. He enjoys surfing the North
Shore of Oahu when he’s not distracted by work.
1439_CCNP_3.book Page v Wednesday, October 27, 2004 9:54 AM

About the Technical Reviewers


Mark Gallo is a technical manager with America Online, where he leads a group of engi-
neers responsible for the design and deployment of the domestic corporate intranet. His net-
work certifications include Cisco CCNP and Cisco CCDP. He has led several engineering
groups responsible for designing and implementing enterprise LANs and international IP net-
works. He has a bachelor of science in electrical engineering from the University of Pitts-
burgh. He resides in northern Virginia with his wife, Betsy, and son, Paul.
Stanford M. Wong, CCIE No. 8038, CCAI, MCSE, received his bachelor of science electrical
engineering from the University of Hawaii and his master of business administration from the
University of Phoenix. He is the owner and founder of Complete Network Solutions Corporation
(CNSC). He is responsible for providing global enterprise networking solutions to the U.S.
Government and commercial customers. He has 20 years in the networking industry; recently
his work has focused on MPLS, VPN, and VoIP technologies. In addition, he instructs CCNP
Cisco Networking Academy courses at Honolulu Community College.
Jim Yoshida, CCDA, CCNP, is the Cisco Networking Academy Program main contact and a
CCNA and CCNP instructor at Hawaii Community College. He has more than 20 years of
teaching experience and has been involved with the Cisco Networking Academy Program
since 1998. In addition to being responsible for overseeing the Cisco Networking Academy
Program and conducting classes, he has worked closely with members of the Cisco World
Wide Education team on CCNP curriculum development.
1439_CCNP_3.book Page vi Wednesday, October 27, 2004 9:54 AM

vi

Overview

Foreword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xxii

Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxiv

Chapter 1 Campus Networks and Design Models. . . . . . . . . . . . . . . . . . . . . .3

Chapter 2 VLANs and VTP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67

Chapter 3 Spanning Tree Protocol (STP) . . . . . . . . . . . . . . . . . . . . . . . . . . .153

Chapter 4 Inter-VLAN Routing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .259

Chapter 5 Multilayer Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .293

Chapter 6 Redundancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .341

Chapter 7 Cisco AVVID. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .385

Chapter 8 Quality of Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .483

Chapter 9 Monitoring and Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .545

Chapter 10 Transparent LAN Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .649

Appendix A Check Your Understanding Answer Key. . . . . . . . . . . . . . . . . . .677

Appendix B Gigabit Ethernet and 10 Gigabit Ethernet Standards and


Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .701

Appendix C Using the Catalyst Operating System. . . . . . . . . . . . . . . . . . . . .709

Glossary 735

Index 755
1439_CCNP_3.book Page vii Wednesday, October 27, 2004 9:54 AM

vii

Table of Contents

Foreword xxii

Introduction xxiv

Chapter 1 Campus Networks and Design Models . . . . . . . . . . . . . . . . . . . . . 3


Overview of a Campus Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Traditional Campus Networks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Issues with Traditional Campus Network Designs . . . . . . . . . . . . . . .5
Traditional 80/20 Rule of Network Traffic. . . . . . . . . . . . . . . . . . . . . .7
The New 20/80 Rule of Network Traffic . . . . . . . . . . . . . . . . . . . . . . .8
Key Requirements of the Evolving Campus Structure . . . . . . . . . . . .9
Evolving Campus Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Key Characteristics of Various Switching Technologies . . . . . . . . . . . .11
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Layer 2 Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Layer 3 Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Layer 4 Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Multilayer Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Quality of Service (QoS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Multicast. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Hierarchical Design Model for Campus Networks . . . . . . . . . . . . . .20
Building-Block Approach . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
The Switch Block. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Scaling the Switch Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Building the Core Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Layer 2 and Layer 3 Backbone Scaling . . . . . . . . . . . . . . . . . . . . . . .29
Advantages of the Building-Block Approach . . . . . . . . . . . . . . . . . .31
Small Campus Networks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Medium Campus Networks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Large Campus Networks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Basic Configuration of the Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Cabling the Switch Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Connecting to the Console Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Connecting to an Ethernet Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
Clearing a Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
Setting a Password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
Naming the Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
Configuring the Switch for Remote Access . . . . . . . . . . . . . . . . . . . .46
1439_Final_Fmatter.fm Page viii Wednesday, October 27, 2004 12:49 PM

viii

Identifying Individual Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48


Defining Port Speed and Line Mode on a Switch . . . . . . . . . . . . . . .50
Important IOS Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
Command-Line Recall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
Using the Help Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
Password Recovery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
Setting an Idle Timeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
Verifying Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
Backup and Restoration of a Configuration Using a TFTP Server . .58
HTTP Access to the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60
Key Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
Check Your Understanding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63

Chapter 2 VLANs and VTP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67


VLAN Basics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
Describe a VLAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
Motivation for VLANs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70
VLANs and Network Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71
VLANs and Broadcast Distribution . . . . . . . . . . . . . . . . . . . . . . . . . .73
VLANs and Bandwidth Utilization . . . . . . . . . . . . . . . . . . . . . . . . . .74
VLANs Versus Router Latency . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75
Wrong Motives for Implementing VLANs . . . . . . . . . . . . . . . . . . . .76
VLAN Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77
Understanding Switch ACLs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
Router ACLs and VLAN Maps . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79
Configuring Router ACLs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81
Configuring VLAN Maps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83
Using VLAN Maps with Router ACLs . . . . . . . . . . . . . . . . . . . . . . .88
Applying Router ACLs and VLAN Maps on VLANs . . . . . . . . . . . .90
VLAN Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92
VLAN Boundaries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .93
End-to-End VLANs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94
Local VLANs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95
Establishing VLAN Memberships . . . . . . . . . . . . . . . . . . . . . . . . . . .96
Port-Based VLAN Membership. . . . . . . . . . . . . . . . . . . . . . . . . . . . .96
Dynamic VLANs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .98
1439_CCNP_3.book Page ix Wednesday, October 27, 2004 9:54 AM

ix

Configuring VLANs and VMPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100


Configuring Static VLANs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100
Verifying VLAN Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . .102
Deleting VLANs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .102
VMPS Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .103
VMPS Configuration Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . .105
Access Links and Trunk Links. . . . . . . . . . . . . . . . . . . . . . . . . . . . .109
VLAN Trunking and Dynamic Trunking Protocol . . . . . . . . . . . . . . .111
Trunking Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111
Configuring a VLAN Trunk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112
Removing VLANs from a Trunk . . . . . . . . . . . . . . . . . . . . . . . . . . .113
Basics of Dynamic Trunking Protocol . . . . . . . . . . . . . . . . . . . . . . .114
DTP Trunk and Access Modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . .116
DTP Combinations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .117
Verifying DTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120
VLAN Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .122
VLAN Frame Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .123
Inter-Switch Link (ISL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .123
The IEEE 802.1Q Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125
The IEEE 802.10 Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126
LAN Emulation (LANE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127
VLAN Trunking Protocol (VTP). . . . . . . . . . . . . . . . . . . . . . . . . . . . .128
VTP Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .128
VTP Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .129
VTP Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .131
Adding a Switch to a VTP Domain . . . . . . . . . . . . . . . . . . . . . . . . .133
VTP Advertisements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134
VTP Configuration and VTP Pruning . . . . . . . . . . . . . . . . . . . . . . . . .138
Basic Configuration Steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138
Configuring the VTP Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
Configuring the VTP Domain . . . . . . . . . . . . . . . . . . . . . . . . . . . . .140
Configuring the VTP Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141
Verifying VTP Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .142
Default Behavior of a Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .143
Configuring VTP Pruning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144
Verifying VTP Pruning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .146
Key Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .147
Check Your Understanding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148
1439_CCNP_3.book Page x Wednesday, October 27, 2004 9:54 AM

Chapter 3 Spanning Tree Protocol (STP) . . . . . . . . . . . . . . . . . . . . . . . . . . .153


STP Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .154
STP Concepts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .154
Broadcast Loops. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .154
Bridge Table Corruption. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .156
Bridge Priority . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .158
Path Cost . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .159
Port ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160
STP Processes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .161
STP Decisions and BPDU Exchanges . . . . . . . . . . . . . . . . . . . . . . .162
Three Steps of STP Convergence. . . . . . . . . . . . . . . . . . . . . . . . . . .163
Electing the Root Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .164
Electing Root Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .165
Electing Designated Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166
STP States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .168
STP Timers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .171
BPDU Format. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .174
Topology Changes and STP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .176
STP Enhancements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177
Delay in STP Updates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177
PortFast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .178
UplinkFast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180
BackboneFast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .182
802.1w Rapid STP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .185
RSTP States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .186
RSTP Port Roles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .187
RSTP Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190
RSTP BPDU Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194
Evolution of Spanning Tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .195
PVST (Per-VLAN Spanning Tree), PVST+, and Mono Spanning
Tree Modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .195
Enhanced PVST+. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .198
MST (802.1s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .199
Load Sharing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201
Switchport Tuning Using BPDU Guard. . . . . . . . . . . . . . . . . . . . . .203
Switchport Tuning Using Root Guard . . . . . . . . . . . . . . . . . . . . . . .205
STP Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .207
Default STP Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .207
Enabling and Disabling STP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .208
Modifying the Root Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .208
1439_CCNP_3.book Page xi Wednesday, October 27, 2004 9:54 AM

xi

Setting the Priority for Ports and VLANs . . . . . . . . . . . . . . . . . . . .210


Setting the Port Cost . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .212
Configuring Switch Priority of a VLAN . . . . . . . . . . . . . . . . . . . . .213
Modifying Default Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .214
Tuning, Verifying, and Troubleshooting STP . . . . . . . . . . . . . . . . . . .216
Configuring PortFast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .216
Configuring UplinkFast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217
Configuring BackboneFast. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .218
Configuring BPDU Guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .219
Configuring Root Guard. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220
Configuring Load Sharing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221
Verifying STP, RSTP, and MSTP Configuration . . . . . . . . . . . . . . .225
RSTP and MSTP Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . .226
Default RSTP and MSTP Configuration . . . . . . . . . . . . . . . . . . . . .226
RSTP and MSTP Configuration Guidelines . . . . . . . . . . . . . . . . . .227
Enabling RSTP and MSTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .228
Configuring the MST Root Switch . . . . . . . . . . . . . . . . . . . . . . . . .230
Configuring MST Switch Priority . . . . . . . . . . . . . . . . . . . . . . . . . .232
Configuring MST Path Cost. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .232
Configuring MST Port Priority . . . . . . . . . . . . . . . . . . . . . . . . . . . .234
Configuring MSTP Timers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .235
Configuring Maximum Hop Count . . . . . . . . . . . . . . . . . . . . . . . . .237
EtherChannel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .237
EtherChannel Explained . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .238
Frame Distribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .240
EtherChannel Methods. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .241
Port Aggregation Protocol (PAgP) . . . . . . . . . . . . . . . . . . . . . . . . . .242
Link Aggregation Control Protocol (LACP) . . . . . . . . . . . . . . . . . .244
Modifying Port Cost for EtherChannel Groups . . . . . . . . . . . . . . . .245
EtherChannel Configuration Guidelines . . . . . . . . . . . . . . . . . . . . .245
Configuring Fast EtherChannel . . . . . . . . . . . . . . . . . . . . . . . . . . . .249
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250
Key Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .252
Check Your Understanding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .254

Chapter 4 Inter-VLAN Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259


Methods of Inter-VLAN Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . .259
Key Components of Inter-VLAN Routing. . . . . . . . . . . . . . . . . . . .259
Comparison of Layer 2 and Layer 3 Operations in the Core . . . . . .262
Inter-VLAN Routing Performance and Scalability Issues. . . . . . . .263
1439_CCNP_3.book Page xii Wednesday, October 27, 2004 9:54 AM

xii

Roles of the Different Types of VLANs. . . . . . . . . . . . . . . . . . . . . .265


Route Switch Processors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .269
Router-on-a-Stick . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .271
When to Use the Router-on-a-Stick Design. . . . . . . . . . . . . . . . . . .272
Cisco Layer 3 Feature Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .273
Configuring Inter-VLAN Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . .274
Configuring Inter-VLAN Routing in a Switched Network . . . . . . .274
Configuring Inter-VLAN Routing Via the Switch Virtual
Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .274
Configuring Inter-VLAN Routing Via the Routed Port . . . . . . . . . .275
Configuring Routing Between an External Router and an Internal
Route Processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .276
Configuring the Router for the Native VLAN . . . . . . . . . . . . . . . . .277
Configuring Router-on-a-Stick. . . . . . . . . . . . . . . . . . . . . . . . . . . . .279
Verifying the Inter-VLAN Routing Configuration. . . . . . . . . . . . . .282
Troubleshooting Inter-VLAN Routing. . . . . . . . . . . . . . . . . . . . . . .286
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .287
Key Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .288
Check Your Understanding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .289

Chapter 5 Multilayer Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .293


Multilayer Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .294
MLS Hardware and Software Requirements . . . . . . . . . . . . . . . . . .294
MLS Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .296
MLS Flows. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .297
MLS Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .300
Cisco Express Forwarding (CEF) . . . . . . . . . . . . . . . . . . . . . . . . . . . .303
Comparing MLS and CEF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .303
CEF Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .308
CEF Forwarding Information Base . . . . . . . . . . . . . . . . . . . . . . . . .309
CEF Adjacency Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .311
Packet Flow for Layer 2 and Layer 3 Forwarding Decisions. . . . . .311
Additional Benefits of CEF-Based Forwarding . . . . . . . . . . . . . . . .313
MLS and CEF Configuration Tasks. . . . . . . . . . . . . . . . . . . . . . . . . . .315
MLS-RP Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .315
MLS-SE Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .317
Configuring MLS Optional Parameters . . . . . . . . . . . . . . . . . . . . . .318
MLS Configuration Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .320
MLS Verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .326
CEF Configuration and Verification . . . . . . . . . . . . . . . . . . . . . . . . .331
1439_CCNP_3.book Page xiii Wednesday, October 27, 2004 9:54 AM

xiii

Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .334
Key Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .335
Check Your Understanding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .337

Chapter 6 Redundancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 341


Implementing Module Redundancy in a Multilayer Switched
Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .342
Implementing Redundant Supervisor Engines in Catalyst
Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .342
Implementing Redundant Supervisor Uplink Modules in Catalyst
Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .344
Implementing Redundant Distributed Forwarding Cards in Catalyst
Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .347
Implementing Redundant Power Supplies . . . . . . . . . . . . . . . . . . . .348
Implementing Router Redundancy in a Switched Network . . . . . . . .349
Router Redundancy Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . .350
ICMP Router Discovery Protocol (IRDP) . . . . . . . . . . . . . . . . . . . .352
Hot Standby Router Protocol (HSRP) . . . . . . . . . . . . . . . . . . . . . . .352
Virtual Router Redundancy Protocol (VRRP) . . . . . . . . . . . . . . . . .355
Gateway Load Balancing Protocol (GLBP). . . . . . . . . . . . . . . . . . .356
Single Router Mode (SRM) Redundancy . . . . . . . . . . . . . . . . . . . .360
Server Load Balancing (SLB) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .361
HSRP Operations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .363
The Virtual Router MAC Address . . . . . . . . . . . . . . . . . . . . . . . . . .366
HSRP Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .368
HSRP States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .369
HSRP Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .369
How HSRP Addresses Redundancy Issues . . . . . . . . . . . . . . . . . . .371
HSRP Standby Priority . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .372
HSRP Standby Preempt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .373
HSRP Hello Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .373
HSRP Interface Tracking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .375
Verify HSRP Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .376
HSRP over Trunk Links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .377
Troubleshooting HSRP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .378
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .379
Key Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .380
Check Your Understanding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .381
1439_CCNP_3.book Page xiv Wednesday, October 27, 2004 9:54 AM

xiv

Chapter 7 Cisco AVVID. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .385


Introduction to Cisco AVVID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .386
Examining the Cisco AVVID Framework . . . . . . . . . . . . . . . . . . . .386
Cisco AVVID Network Infrastructure . . . . . . . . . . . . . . . . . . . . . . .388
Cisco AVVID Intelligent Network Services. . . . . . . . . . . . . . . . . . .391
High Availability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .393
Cisco AVVID Network Solutions . . . . . . . . . . . . . . . . . . . . . . . . . .395
Cisco AVVID Network Implementation Example . . . . . . . . . . . . . .401
Legacy Migration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .403
Examining Multicast in a Multilayer Switched Network . . . . . . . . . .406
Multicast Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .406
Multicast Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .408
Layer 3 Multicast Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . .409
Layer 2 Multicast Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . .411
IGMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .412
IGMP Version 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .412
IGMP Version 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .415
IGMP Version 1 and Version 2 Interoperability . . . . . . . . . . . . . . . .417
IGMP Version 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .418
IGMP Snooping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .419
CGMP Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .422
Routing Multicast Traffic. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .424
Distribution Trees. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .425
Managing Delivery of Multicast Packets . . . . . . . . . . . . . . . . . . . . .428
Reverse Path Forwarding (RPF). . . . . . . . . . . . . . . . . . . . . . . . . . . .430
Multicast Routing Protocols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .432
Dense-Mode Routing Protocols . . . . . . . . . . . . . . . . . . . . . . . . . . . .432
Distance Vector Multicast Routing Protocol . . . . . . . . . . . . . . . . . .433
Protocol-Independent Multicast Dense Mode . . . . . . . . . . . . . . . . .433
Multicast Open Shortest Path First . . . . . . . . . . . . . . . . . . . . . . . . .434
Sparse Mode Routing Protocols. . . . . . . . . . . . . . . . . . . . . . . . . . . .434
Core-Based Trees . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .435
PIM-SM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .436
Configure IP Multicast Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . .437
Verify PIM Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .438
Configure Auto-RP (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .439
Optional IP Multicast Routing Tasks . . . . . . . . . . . . . . . . . . . . . . . .441
Cisco IP Telephony . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .444
Introducing the Cisco IP Telephony Solution . . . . . . . . . . . . . . . . .445
Cisco IP Telephony Designs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .450
1439_CCNP_3.book Page xv Wednesday, October 27, 2004 9:54 AM

xv

Single-Site Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .450


Multiple Sites with Independent Call Processing . . . . . . . . . . . . . .451
Multiple Sites with Distributed Call Processing . . . . . . . . . . . . . . .452
Multisite IP WAN with Centralized Call Processing . . . . . . . . . . . .454
Voice Quality Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .455
Common Voice Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .455
Implementing QoS for Voice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .457
QoS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .458
Trust Boundaries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .459
Traffic Classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .461
Traffic Classification at Layer 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . .462
Traffic Classification at Layer 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . .463
Summary Recommendations for QoS Implementation . . . . . . . . . .464
Network Design Issues for Voice. . . . . . . . . . . . . . . . . . . . . . . . . . . . .465
IP Phone Physical Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . .465
Power/Protection Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .465
Power to IP Phones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .466
Infrastructure Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .467
High Availability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .467
IP Addressing and Management . . . . . . . . . . . . . . . . . . . . . . . . . . .468
Implementing IP Telephony with Auxiliary VLANs . . . . . . . . . . . .470
Voice VLAN Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .470
Connecting to the Network with Auxiliary VLANs. . . . . . . . . . . . .471
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .472
Key Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .475
Check Your Understanding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .479

Chapter 8 Quality of Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 483


Quality of Service Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . .484
Quality of Service Defined. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .484
Loss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .485
Delay or Latency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .485
Delay Variation or Jitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .486
Network Availability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .486
Provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .487
Quality of Service Requirements for Data . . . . . . . . . . . . . . . . . . . .487
Quality of Service Requirements for Voice . . . . . . . . . . . . . . . . . . .488
Quality of Service Requirements for Video . . . . . . . . . . . . . . . . . . .488
1439_CCNP_3.book Page xvi Wednesday, October 27, 2004 9:54 AM

xvi

Quality of Service Mechanisms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .490


Best-Effort Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .490
Integrated Services Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .491
Differentiated Services Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . .492
Traffic Marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .492
Modular QoS Command-Line Interface (MQC) . . . . . . . . . . . . . . .495
Using the class-map Command to Define Traffic Classes . . . . . . . .495
Defining the QoS Policy Using the Policy Map. . . . . . . . . . . . . . . .497
Applying the Policy to an Interface Using the Service Policy. . . . .499
Classification at the Access Layer . . . . . . . . . . . . . . . . . . . . . . . . . . . .499
Trusting the CoS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .499
Configuring CoS Trust Using the IOS . . . . . . . . . . . . . . . . . . . . . . .500
Assigning CoS on a Per-Port Basis . . . . . . . . . . . . . . . . . . . . . . . . .501
Rewriting the CoS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .501
Using a MAC ACL to Assign a DSCP Value . . . . . . . . . . . . . . . . . .502
Configuring DSCP Using a MAC ACL . . . . . . . . . . . . . . . . . . . . . .504
Using an IP ACL to Define the DSCP or Precedence . . . . . . . . . . .507
Policing and Marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .509
Individual Policers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .509
Aggregate Policers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .510
Token Bucket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .511
Classification and Policing Using Committed Access
Rate (CAR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .512
Configuring the Policed DSCP Map . . . . . . . . . . . . . . . . . . . . . . . .512
Configuring Classification Using CAR . . . . . . . . . . . . . . . . . . . . . .514
Configuring Policing Using CAR . . . . . . . . . . . . . . . . . . . . . . . . . .515
Scheduling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .516
FIFO Queue . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .516
Weighted Fair Queuing (WFQ) . . . . . . . . . . . . . . . . . . . . . . . . . . . .516
WFQ and IP Precedence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .518
Class-Based Weighted Fair Queuing (CBWFQ) . . . . . . . . . . . . . . .519
Configuring CBWFQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .520
CBWFQ Bandwidth Allocation . . . . . . . . . . . . . . . . . . . . . . . . . . . .522
Congestion Avoidance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .522
Weighted Random Early Detection (WRED) . . . . . . . . . . . . . . . . .523
Configuring WRED on a Physical Interface . . . . . . . . . . . . . . . . . .524
Verifying WRED Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . .525
Configuring WRED with CBWFQ . . . . . . . . . . . . . . . . . . . . . . . . .525
Low Latency Queuing (LLQ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .526
Configuring LLQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .527
1439_CCNP_3.book Page xvii Wednesday, October 27, 2004 9:54 AM

xvii

Traffic Shaping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .528


Generic Traffic Shaping (GTS) . . . . . . . . . . . . . . . . . . . . . . . . . . . .529
Configuring GTS for an Interface . . . . . . . . . . . . . . . . . . . . . . . . . .530
GTS for Frame Relay Networks . . . . . . . . . . . . . . . . . . . . . . . . . . .531
Configuring GTS for Frame Relay Networks . . . . . . . . . . . . . . . . .532
Verifying GTS Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .532
QoS Using Low-Speed Links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .533
Link Efficiency Mechanisms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .534
Link Fragmentation and Interleaving (LFI) . . . . . . . . . . . . . . . . . . .534
Link Fragmentation and Interleaving (LFI): Multilink PPP . . . . . .535
Compressed Real-Time Protocol (CRTP) . . . . . . . . . . . . . . . . . . . .536
Configuring CRTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .537
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .538
Key Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .539
Check Your Understanding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .541

Chapter 9 Monitoring and Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 545


Monitoring Switched Network Performance with SPAN
and VSPAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .545
Monitoring with SPAN on a Port Basis . . . . . . . . . . . . . . . . . . . . . .546
SPAN Interaction with Other Features. . . . . . . . . . . . . . . . . . . . . . .548
SPAN Configuration Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . .549
Configuring SPAN Sessions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .550
VSPAN—SPAN Using VLANs as Monitored Source. . . . . . . . . . .552
RSPAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .555
RSPAN Reflector Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .556
RSPAN Interaction with Other Features . . . . . . . . . . . . . . . . . . . . .557
RSPAN and RSPAN VLANs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .557
Configuring RSPAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .558
Configuring RSPAN to Filter Trunks for Specific VLAN Traffic . .562
Network Analysis Modules and Switch Fabric Modules. . . . . . . . . . .564
The Network Analysis Module . . . . . . . . . . . . . . . . . . . . . . . . . . . .566
Using the NAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .567
Benefits of Deploying a NAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . .569
NAM Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .569
Increasing Switching Fabric in Catalyst 6500 Series Switches . . . .570
Configuring the Switch Fabric Module . . . . . . . . . . . . . . . . . . . . . .572
Monitoring the Switch Fabric Module. . . . . . . . . . . . . . . . . . . . . . .572
1439_CCNP_3.book Page xviii Wednesday, October 27, 2004 9:54 AM

xviii

Basic Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .575


Access Control Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .575
Basic Security Measures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .577
Physical Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .577
Connecting to the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .579
Out-of-Band Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .579
In-Band Management. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .581
Basic Password Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .582
Securing Remote Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .585
Remote Management Security Options . . . . . . . . . . . . . . . . . . . . . .585
Advanced Username Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .585
Encrypting Communications Using Secure Shell . . . . . . . . . . . . . .587
Encryption Key Pairs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .589
Using VLANs to Restrict Remote Management . . . . . . . . . . . . . . .591
Securing the Web Management Interface . . . . . . . . . . . . . . . . . . . .592
Using Access Lists to Restrict Remote Management . . . . . . . . . . .593
Additional Remote Management Session Options . . . . . . . . . . . . .595
Configuring, Verifying, and Troubleshooting SSH Server. . . . . . . .596
Securing User Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .598
Using Port Security, Protected Ports, and Private VLANs. . . . . . . .598
Using Access Lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .600
Router ACLs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .602
Port ACLs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .604
VLAN ACLs and VLAN Maps . . . . . . . . . . . . . . . . . . . . . . . . . . . .604
Configuring and Verifying Port Security . . . . . . . . . . . . . . . . . . . . .607
Configuring and Verifying Protected Ports . . . . . . . . . . . . . . . . . . .609
Configuring and Verifying Access Lists. . . . . . . . . . . . . . . . . . . . . .610
Authentication, Authorization, and Accounting (AAA) . . . . . . . . . . .614
TACACS+ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .615
RADIUS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .616
Cisco Secure Access Control Server (ACS). . . . . . . . . . . . . . . . . . .618
Configuring AAA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .619
Configuring TACACS+ and RADIUS Clients . . . . . . . . . . . . . . . . .620
Configuring AAA Authentication . . . . . . . . . . . . . . . . . . . . . . . . . .621
Configuring AAA Authorization . . . . . . . . . . . . . . . . . . . . . . . . . . .625
Configuring AAA Accounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . .630
IEEE 802.1x Port-Based Authentication . . . . . . . . . . . . . . . . . . . . . . .634
Authentication Initiation and Message Exchange . . . . . . . . . . . . . .635
Ports in Authorized and Unauthorized States . . . . . . . . . . . . . . . . .637
Supported Topologies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .638
1439_CCNP_3.book Page xix Wednesday, October 27, 2004 9:54 AM

xix

802.1x Configuration Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . .639


Configuring 802.1x Port-Based Authentication . . . . . . . . . . . . . . . .640
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .643
Key Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .644
Check Your Understanding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .645

Chapter 10 Transparent LAN Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 649


Ethernet Solutions for Transparent LAN Services (TLS) . . . . . . . . . .649
Same Network, New Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . .649
VLAN Tunneling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .651
Intermetro LAN Transport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .652
Interservice POP Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . .653
Metro Segmentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .654
Introducing Transparent LAN Services Architecture . . . . . . . . . . . . .655
Metro Ethernet Services. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .655
IP+Optical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .656
Point-to-Point Dedicated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .657
Point-to-Multipoint Shared . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .658
Role of QoS in TLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .659
Examining Fiber-Optic Transports . . . . . . . . . . . . . . . . . . . . . . . . . . .660
Defining SONET and SDH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .660
Applications for SONET/SDH. . . . . . . . . . . . . . . . . . . . . . . . . . . . .664
Implementing SONET/SDH Within a Metropolitan Network. . . . .664
Defining Dynamic Packet Transport (DPT) . . . . . . . . . . . . . . . . . . .665
Defining CWDM and DWDM . . . . . . . . . . . . . . . . . . . . . . . . . . . . .666
Implementing DWDM Over a MAN . . . . . . . . . . . . . . . . . . . . . . . .667
10 Gigabit Ethernet Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . .669
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .671
Key Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .672
Check Your Understanding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .672

Appendix A Check Your Understanding Answer Key . . . . . . . . . . . . . . . . . . 677

Appendix B Gigabit Ethernet and 10 Gigabit Ethernet Standards and


Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 701

Appendix C Using the Catalyst Operating System . . . . . . . . . . . . . . . . . . . . 709

Glossary 735

Index 755
1439_CCNP_3.book Page xx Wednesday, October 27, 2004 9:54 AM

xx

Cisco Systems Networking Icon Legend


Cisco Systems, Inc. uses a standardized set of icons to represent devices in network topology
illustrations. The following icon legend shows the most commonly used icons you will
encounter throughout this book.

Cache Local Multilayer


Laptop Web Engine Director Switch Feature
Access PC
Server Card (MSFC)
Server

Token
Ring
Small Hub Distributed
Token Ring File Director
Multilayer Gateway
Server
Route/Switch Switch
Processor

V
POTS NetRanger PIX Firewall Router Voice-Enabled
Phone IP Phone
Firewall Router

Modem
Cisco Bridge
Database Hub Cisco
Storage Router Optical
CallManager Services
Router

PL M
Switch Wireless
ATM Access Port MGX 8240 MGX 8260
Optical
Switch Transport

Wireless
Connection
Printer
Cisco SoftPhone ONS
Network Cloud Device

EtherClient VPN Optical


TransPath
Concentrator Cross-Connect

Ethernet Connection Serial Connection Circuit-Switched Connection


1439_CCNP_3.book Page xxi Wednesday, October 27, 2004 9:54 AM

xxi

Command Syntax Conventions


The conventions used to present command syntax in this book are the same conventions used
in the Cisco IOS software Command Reference. The Command Reference describes these
conventions as follows:
■ Bold indicates commands and keywords that are entered exactly as shown.
■ Italic indicates arguments for which you supply values.
■ Vertical bars (|) separate alternative, mutually exclusive elements.
■ Square brackets ([ ]) indicate an optional element.
■ Braces ({ }) indicate a required choice.
■ Braces within brackets ([{ }]) indicate a required choice within an optional element.
1439_CCNP_3.book Page xxii Wednesday, October 27, 2004 9:54 AM

xxii

Foreword
Throughout the world, the Internet has offered tremendous new opportunities for individuals
and their employers. Companies and other organizations are seeing dramatic increases in pro-
ductivity by investing in robust networking capabilities. Some studies have shown measur-
able productivity improvements in entire economies. The promise of enhanced efficiency,
profitability, and standard of living is real and growing.
Such productivity gains aren’t achieved by simply purchasing networking equipment. Skilled
professionals are needed to plan, design, install, deploy, configure, operate, maintain, and
troubleshoot today’s networks. Network managers must ensure that they have planned for
network security and continued operation. They need to design for the required performance
level in their organization. They must implement new capabilities as the demands of their
organization, and its reliance on the network, expand.
To meet the many educational needs of the internetworking community, Cisco Systems estab-
lished the Cisco Networking Academy Program. The Networking Academy is a comprehen-
sive learning program that provides students with the Internet technology skills that are
essential in a global economy. The Networking Academy integrates face-to-face teaching,
web-based content, online assessment, student performance tracking, hands-on labs, instruc-
tor training and support, and preparation for industry-standard certifications.
The Networking Academy continually raises the bar on blended learning and educational
processes. The Internet-based assessment and instructor support systems are some of the
most extensive and validated systems ever developed, including a 24/7 customer service
system for Networking Academy instructors. Through community feedback and electronic
assessment, the Networking Academy adapts the curriculum to improve outcomes and stu-
dent achievement. The Cisco Global Learning Network infrastructure designed for the Net-
working Academy delivers a rich, interactive, personalized curriculum to students worldwide.
The Internet has the power to change how people work, live, play, and learn, and the Cisco
Networking Academy Program is at the forefront of this transformation.
This Cisco Press book is one in a series of best-selling companion titles for the Cisco Net-
working Academy Program. Designed by Cisco Worldwide Education and Cisco Press, these
books provide integrated support for the online learning content that is made available to
Academies all over the world. These Cisco Press books are the only books authorized for the
Networking Academy by Cisco Systems. They provide print and CD-ROM materials that
ensure the greatest possible learning experience for Networking Academy students.
I hope you are successful as you embark on your learning path with Cisco Systems and the
Internet. I also hope that you will choose to continue your learning after you complete the
Networking Academy curriculum. In addition to its Cisco Networking Academy Program
titles, Cisco Press publishes an extensive list of networking technology and certification
1439_CCNP_3.book Page xxiii Wednesday, October 27, 2004 9:54 AM

xxiii

publications that provide a wide range of resources. Cisco Systems has also established a net-
work of professional training companies—the Cisco Learning Partners—that provide a full
range of Cisco training courses. They offer training in many formats, including e-learning,
self-paced, and instructor-led classes. Their instructors are Cisco-certified, and Cisco creates
their materials. When you are ready, please visit the Learning & Events area at Cisco.com to
learn about all the educational support that Cisco and its partners have to offer.
Thank you for choosing this book and the Cisco Networking Academy Program.
The Cisco Networking Academy Team
Cisco Systems, Inc.
1439_CCNP_3.book Page xxiv Wednesday, October 27, 2004 9:54 AM

xxiv

Introduction
This companion guide is designed as a desk reference to supplement your classroom and lab-
oratory experience with version 3 of the CCNP 3 course in the Cisco Networking Academy
Program.
CCNP 3: Multilayer Switching is the third of four courses leading to the Cisco Certified Net-
work Professional certification. CCNP 3 teaches you how to design, configure, maintain, and
scale multilayer switched networks. You will learn to use VLANs, STP, VTP, inter-VLAN
routing, redundancy, QoS, and security on Catalyst switches. While taking the course, use
this companion guide to help you prepare for the Building Cisco Multilayer Switched Net-
works (BCMSN) 642-811 BCMSN exam, which is one of the four required exams to obtain
the CCNP certification.

This Book’s Goal


The goal of this book is to build on the switching concepts you learned while studying for the
CCNA exam and to teach you the foundations of advanced switching concepts. The topics are
designed to prepare you to pass the Building Cisco Multilayer Switched Networks (BCMSN)
exam (642-811 BCMSN).
The Building Cisco Multilayer Switched Networks exam is a qualifying exam for the CCNP,
CCDP, and CCIP certifications. The 642-811 BCMSN exam tests materials covered under the
new Building Cisco Multilayer Switched Networks course and exam objectives. The exam
certifies that the successful candidate has the knowledge and skills necessary to use multi-
layer switching to implement campus networks with Catalyst switches. The exam covers
campus network design, STP, VTP, inter-VLAN routing, redundancy techniques, basic Cisco
IP BCMSN Telephony, QoS, and security.
The key methodologies used in this book are to help you discover the exam topics you need
to review in more depth, to help you fully understand and remember those details, and to help
you prove to yourself that you have retained your knowledge of those topics. This book does
not try to help you pass by memorization; it helps you truly learn and understand the topics.
This book focuses on introducing techniques and technology for enabling WAN solutions. To
fully benefit from this book, you should be familiar with general networking terms and con-
cepts and should have basic knowledge of the following:
■ Basic Cisco router and Catalyst switch operation and configuration
■ TCP/IP operation and configuration
■ VLANs, STP, VTP, and inter-VLAN routing
1439_CCNP_3.book Page xxv Wednesday, October 27, 2004 9:54 AM

xxv

This Book’s Audience


This book has a few different audiences. First, it is intended for students who are interested in
multilayer switching technologies. In particular, it is targeted toward students in the Cisco
Networking Academy Program CCNP 3: Multilayer Switching course. In the classroom, this
book serves as a supplement to the online curriculum. This book is also appropriate for cor-
porate training faculty and staff members, as well as general users.
This book is also useful for network administrators who are responsible for implementing
and troubleshooting enterprise Cisco routers and router configuration. Furthermore, it is valu-
able for anyone who is interested in learning advanced switching concepts and passing the
Building Cisco Multilayer Switched Networks (BCMSN) exam (642-811 BCMSN).

This Book’s Features


Many of this book’s features help facilitate a full understanding of the topics covered in this
book:
■ Objectives—Each chapter starts with a list of objectives that you should have mastered
by the end of the chapter. The objectives reference the key concepts covered in the
chapter.
■ Figures, examples, tables, and scenarios—This book contains figures, examples, and
tables that help explain theories, concepts, commands, and setup sequences that rein-
force concepts and help you visualize the content covered in the chapter. In addition,
the specific scenarios provide real-life situations that detail the problem and its
solution.
■ Chapter summaries—At the end of each chapter is a summary of the concepts cov-
ered in the chapter. It provides a synopsis of the chapter and serves as a study aid.
■ Key terms—Each chapter includes a list of defined key terms that are covered in the
chapter. The key terms appear in color throughout the chapter where they are used in
context. The definitions of these terms serve as a study aid. In addition, the key terms
reinforce the concepts introduced in the chapter and help you understand the chapter
material before you move on to new concepts.
■ Check Your Understanding questions and answers—Review questions, presented at
the end of each chapter, serve as a self-assessment tool. They reinforce the concepts
introduced in the chapter and help test your understanding before you move on to a new
chapter. An answer key to all the questions is provided in Appendix A, “Check Your
Understanding Answer Key.”
1439_CCNP_3.book Page xxvi Wednesday, October 27, 2004 9:54 AM

xxvi

■ Certification exam practice questions—To further assess your understanding, you


will find on the companion CD-ROM a test bank of questions exclusive to Cisco Press
that covers the full range of exam topics published by Cisco Systems for the CCNP
BCMSN # 642-811 exam. The robust test engine is powered by Boson Software, Inc.
■ Skill-building activities—Throughout the book are references to additional skill-
building activities to connect theory with practice. You can easily spot these activities
by the following icons:

Interactive Media Activities


Interactive Media Activities included on the companion CD are hands-on drag-and-
drop, fill-in-the-blank, and matching exercises that help you master basic networking
concepts.

Lab Activity
The collection of lab activities developed for the course can be found in the Cisco
Networking Academy Program CCNP 3: Multilayer Switching Lab Companion
Guide, Second Edition.

How This Book Is Organized


Although you could read this book cover to cover, it is designed to be flexible and to allow
you to easily move between chapters and sections of chapters to cover just the material you
need to work with more. If you do intend to read all the chapters, the order in which they are
presented is the ideal sequence. This book also contains three appendixes. The following list
summarizes the topics of this book’s elements:
■ Chapter 1, “Campus Networks and Design Models”—Good design is the key to the
operation and maintenance of a multilayer switched network. Campus networks can be
described in terms of component building blocks. Campus network design includes
correct placement of Layer 2, Layer 3, and multilayer devices in a campus network.
Basic network management command-line operations with Catalyst switches are
introduced.
■ Chapter 2, “VLANs and VTP”— This chapter explores the role of VLANs and
VLAN protocols in modern campus networks. You learn how to configure VLANs on
Catalyst switches. Trunk encapsulation types are discussed as well as trunk negotiation
with DTP. You learn how to understand and use VLAN management tools, such as
VLAN Trunking Protocol (VTP).
1439_CCNP_3.book Page xxvii Wednesday, October 27, 2004 9:54 AM

xxvii

■ Chapter 3, “Spanning Tree Protocol (STP)”—IEEE 802.1D specifies Spanning Tree


Protocol. STP uses a number of variables to calculate the shortest-path tree for a Layer 2
switched network. You learn what these variables are and how STP is affected by them.
Cisco enhanced the 802.1D standard with the PortFast, UplinkFast, and BackboneFast
extensions. A brief history of STP leading to the present is given. Vendor-neutral RSTP
and MST are introduced. Load sharing with EtherChannel is also described.
■ Chapter 4, “Inter-VLAN Routing”—Inter-VLAN routing can be configured with
various physical and logical topologies. A router with several physical LAN interfaces
can route between distinct connected VLANs. A router connected to a switch via an
ISL or IEEE 802.1Q trunk can route between VLANs. A multilayer switch can route
between VLANs without the intervention of a router. Finally, Catalyst multilayer
switch ports can be configured as Layer 3 ports (router interfaces), in which case they
do not participate in any VLANs. On chassis-based Catalyst switches, inter-VLAN
routing is performed by a number of different line cards and daughter cards, depending
on the platform.
■ Chapter 5, “Multilayer Switching”—Two methods of multilayer switching, also
known as wire-speed routing, have been employed by Catalyst switches in the past.
Cisco’s MLS was used for several years before CEF was invented. MLS operation and
configuration are discussed in this chapter. CEF is now a standard feature on Catalyst
switches and Cisco routers. It provides a method for wire-speed routing by using dedi-
cated ASICs and two data structures (adjacency table and FIB).
■ Chapter 6, “Redundancy”—Redundancy in network design is critical to organiza-
tions being able to maintain services to customers and internal users. Redundancy,
resiliency, and availability are all terms used to describe a network’s ability to deliver
services even when devices or interfaces fail. The goal is to reach the “five nines” of
redundancy—maintaining uptime of 99.999%, during which the network is continu-
ously operating. Redundancy is explored in the following cases:
— Router redundancy with IRDP, HSRP, VRRP, and GLBP
— Redundant uplinks in Catalyst switches
— Power module redundancy in chassis-based Catalyst switches
— Supervisor engine redundancy in Catalyst 6500 switches with SRM
— Server redundancy via SLB
■ Chapter 7, “Cisco AVVID”—Architecture for Voice, Video, and Integrated Data
(AVVID) is Cisco’s hardware and software solution for the integration of voice, video,
and data. AVVID has largely been driven by IP telephony and the push to be an industry
leader in the migration to an IP-based world of communication. This chapter touches
on the various aspects of AVVID in general and IP telephony in particular. Whenever
1439_CCNP_3.book Page xxviii Wednesday, October 27, 2004 9:54 AM

xxviii

IP telephony is discussed, QoS is brought into the conversation, because QoS smoothes
the integration of voice, video, and data; without QoS, IP telephony on an Internet scale
would never be realized. QoS and its role in AVVID is introduced.
Multicasting allows for sending data from one source to many receivers without bur-
dening hosts or network devices that do not need to receive the traffic. Multicast traffic
optimizes bandwidth utilization by using only the links necessary to get the traffic from
the source to the destination. This chapter explains multicasting from scratch and builds
to discussing the three major function areas for multicast protocols: between hosts and
routers, between routers and switches, and between routers.
■ Chapter 8, “Quality of Service”—QoS lets network engineers prescriptively optimize
traffic utilization on network links. The primary force behind the growing dependence
on QoS is the integration of voice, video, and data on IP networks. Service providers
also use QoS to provide various classes of service to their customers. Cisco divides
QoS subject matter into the following six areas:
— Classification
— Congestion management
— Congestion avoidance
— Policing and shaping
— Signaling
— Link efficiency mechanisms
QoS models fall under either the IntServ model or the DiffServ model. This chapter
deals almost entirely with the DiffServ model, which is by far the most common model
used in real-world QoS implementations.
■ Chapter 9, “Monitoring and Security”—Monitoring refers to any software or hard-
ware technology that lets the network engineer monitor network traffic. SPAN, VSPAN,
and RSPAN are software technologies used on Catalyst switches for traffic monitoring.
The network analysis module for the Catalyst 6500 is a dedicated link card used as a
LAN monitoring tool.
Security is just as important in a switched network as it is in any other part of an enter-
prise or campus network. Cisco has a growing list of technologies available on Catalyst
switches to ensure the integrity and confidentiality of data traversing the switched net-
work. This chapter explores the most common network security options deployed in
switched networks.
The content in this chapter roughly falls under the categories of SPAN technologies,
basic Catalyst switch security options, securing remote management of Catalyst
switches, and securing user access via ACLs, AAA, and 802.1X authentication.
1439_CCNP_3.book Page xxix Wednesday, October 27, 2004 9:54 AM

xxix

■ Chapter 10, “Transparent LAN Services”—Transparent LAN services are employed


in metropolitan-area networks to provide geographically remote Ethernet service,
VLAN sanctity over MANs, and integration with various high-speed Layer 1 and Layer 2
fiber-optic transports. Cisco’s ONS product line, along with the Catalyst 3550 and
Catalyst 6500 switches and the Cisco 7600 routers, comprise a collection of network
devices that can deliver state-of-the-art TLS.
■ Appendix A, “Check Your Understanding Answer Key”—This appendix lists the
solutions to the Check Your Understanding Questions in each chapter.
■ Appendix B, “Gigabit Ethernet and 10 Gigabit Ethernet Standards and
Operation”—This appendix introduces the Gigabit and 10 Gigabit Ethernet standards.
■ Appendix C, “Using the Catalyst Operating System”—This appendix introduces the
Catalyst operating system. Companies over the years have deployed Catalyst switches,
such as the 4000, 5000, and 6000 family switches, using the CatOS. Many of these
companies opt not to migrate to the IOS-based alternatives to the CatOS, so Cisco
continues to support CatOS options for these switches. This appendix describes how
to configure common LAN switching features using the Catalyst OS.
■ Glossary—The glossary lists all the key terms that appear throughout the book.

About the CD-ROM


The CD-ROM included with this book contains eighteen Interactive Media Activities from
Cisco Systems, Inc. The Interactive Media Activities are hands-on drag-and-drop, fill-in-the-
blank, and matching exercises that help you master basic networking concepts. The CD-ROM
also contains a test engine by Boson Software, Inc. with a total of 200 multiple choice, drag
and drop, and fill in the blank practice exam questions that are exclusive to Cisco Press. The
questions cover the full range of exam topics published by Cisco Systems for the CCNP
BCMSN # 642-811 exam. Boson Software, Inc. is a software and training company special-
izing in test preparation and hands-on skills acquisition product development. Boson was
among the first software vendors to support Cisco certifications, and is now an authorized
Cisco Learning Partner as well as Premier Reseller. Additional Boson practice tests, simula-
tion products, and other study aids are available at www.boson.com.
1439_CCNP_3.book Page 2 Monday, November 15, 2004 10:35 AM

Objectives
After completing this chapter, you will be able to perform tasks related to the following:
■ Understand the multilayer switching approach to campus networking.
■ Explain the correct placement of Layer 2, Layer 3, and multilayer devices on a campus
network.
■ Develop a logical design for the network irrespective of any product that might be
implemented to guarantee continued scalability.
■ Perform basic command-line interface (CLI) operations on Cisco Catalyst switches,
such as command-line recall, command editing, and uploading and downloading code
images and configuration files.
1439_CCNP_3.book Page 3 Monday, November 15, 2004 10:35 AM

Chapter 1

Campus Networks and Design


Models
As corporate intranets continue to evolve, network managers and architects are faced with a
multitude of options in building and modifying their networks. Starting from a premise that the
existing environment already has a combination of switches and routers within the network, this
chapter shows you how to scale the campus intranet to meet the ever-increasing demands of the
business. In this chapter, you learn about the approach to campus networking called multilayer
switching. This chapter discusses the correct placement of Layer 2, Layer 3, and multilayer
devices on a campus network.
This chapter also describes a set of building blocks, which presents a logical design for the net-
work irrespective of any product that might be implemented. The success of any campus intranet
is based on the placement of network services that, when applied correctly, guarantee continued
scalability.
Finally, this chapter describes the command-line interface (CLI) on Cisco switches, including
aspects such as command-line recall, command editing, uploading and downloading code
images, and configuration files.

Overview of a Campus Network


Here, traditional campus networks and their traffic patterns are described, followed by a discus-
sion of the evolving traffic patterns in modern campus networks and their requirements.
1439_CCNP_3.book Page 4 Monday, November 15, 2004 10:35 AM

4 Chapter 1: Campus Networks and Design Models

Traditional Campus Networks


In the early days of networking, primarily research universities and the military experimented
with computer networks. The term campus network derives from networks built on university
campuses. Today, the term is used more broadly to include networks that span corporate
“campuses,” consisting of buildings, portions of a building, or a collection of colocated build-
ings. Campus size is an important factor in network design. A large campus has several or
many colocated buildings, a medium campus has one or several colocated buildings, and a
small campus resides within a single building.
Historically, campus networks consisted of a single LAN to which new users were added
simply by connecting anywhere on the LAN. Because of the distance limitations of the net-
working media, campus networks usually were confined to a building or several buildings in
close proximity, as shown in Figure 1-1.

Figure 1-1 Traditional Campus Networks Connected Small Groups of Users to Share Local
Resources

Broadcast
Domain

Collision Domain 1 Collision Domain 2

The LAN was a physical network that connected the devices. In the case of Ethernet, all the
devices shared the available half-duplex 10-Mbps network. Because of the carrier sense mul-
tiple access collision detect (CSMA/CD) access method used by Ethernet, the whole LAN
was a single collision domain (such as Collision Domain 1 in Figure 1-1).
Few design considerations were needed to provide user access to the network backbone.
Because of Ethernet’s inherent limitations, physically adjacent users were sometimes con-
nected to a single access device to minimize the number of taps into the backbone. Although
hubs (see Figure 1-2) met this requirement and became standard devices for multiple network
access, increased user demand quickly slowed network performance.
1439_CCNP_3.book Page 5 Monday, November 15, 2004 10:35 AM

Overview of a Campus Network 5

Figure 1-2 Traditional Campus Networks Typically Used Hubs to Connect Users

Workgroup Workgroup Workgroup


Server Server Server

Building A Building B Building C

Access
Layer
Hubs Hubs Hubs

Distribution
Layer

Core FDDI Backbone FDDI Dual Ring


Layer Dual-Homed

Enterprise
Ethernet or Fast Ethernet Port WDM
Servers
FDDI Port LAN PH

Issues with Traditional Campus Network Designs


The two major problems with traditional networks have always been availability and perfor-
mance. These two problems are both affected by the amount of bandwidth available. In a
single collision domain, frames are visible to all devices on the LAN and are free to collide.
Multiport Layer 2 devices, such as bridges and switches, are used to segment the LAN into
discrete collision domains and forward Layer 2 data frames to only the segment of the net-
work that contains the destination address. For example, a 48-port switch has 48 collision
domains. Because the Layer 2 ports separate the LAN into distinct physical segments, they
also help resolve issues related to Ethernet’s distance limitations.
However, frames containing the broadcast Media Access Control (MAC) address are still
flooded throughout the entire broadcast domain. A single network device could malfunction
and flood the network with “noise,” and this could bring down the network. This is where
routers come in. Because routers operate at Layer 3 of the Open System Interconnection
(OSI) model, they can make intelligent decisions about the flow of data to and from a net-
work segment. Routers do not forward broadcasts, so if noise from excessive broadcasts
cripples one logical segment, the router does not forward those broadcasts to other logical
segments.
Traffic that polls the network about component status or availability and that advertises net-
work component status or availability can affect network performance. Two common types
of broadcasts that poll the network are IP Address Resolution Protocol (ARP) requests and
1439_CCNP_3.book Page 6 Monday, November 15, 2004 10:35 AM

6 Chapter 1: Campus Networks and Design Models

NetBIOS name requests. These broadcasts are normally propagated across an entire subnet
and expect the target device to respond directly to the broadcast.
In addition to broadcasts, multicast traffic can also consume a large amount of bandwidth.
Multicast traffic is propagated to a specific group of users, so if deployed correctly, it actually
conserves bandwidth relative to broadcast traffic. Depending on the number of users in a mul-
ticast group or the type of application data contained in the multicast packet, multicast traffic
can consume most, if not all, of the network resources. An example of a multicast implemen-
tation is the Cisco IP/TV solution, which uses multicast packets to transport multimedia such
as audio and video.
As networks grow, so does the amount of broadcast traffic on the network. Excessive broad-
casts reduce the bandwidth available to the end users and force end-user nodes to waste CPU
cycles on unnecessary processes. In a worst-case scenario, broadcast storms can effectively
shut down the network by monopolizing the available bandwidth.
Two methods can address the broadcast issue for large switched LAN sites:
■ Using routers to create many subnets and logically segment the traffic
■ Implementing virtual LANs (VLANs) within the switched network
With the option to use routers (see Figure 1-3), broadcasts do not pass through routers.
Although this approach contains broadcast traffic, the CPU of a traditional router has to pro-
cess each packet. This scenario can create a bottleneck in the network. If a router has an inter-
face on a subnet in which a broadcast storm is occurring, the router CPU might be interrupted
to the extent that the router is unable to process packets destined for other networks in a
timely fashion.

Figure 1-3 Routers Segment Traffic into Independent Broadcast Domains

10.1.1.0 10.1.2.0

10.1.3.0
1439_CCNP_3.book Page 7 Monday, November 15, 2004 10:35 AM

Overview of a Campus Network 7

Figure 1-4 depicts the option to implement VLANs within the switched network. For the
purpose of this curriculum, VLANs are basically defined as broadcast domains. A VLAN
includes a group of end devices that populate multiple physical LAN segments and switch
ports. They communicate as if they were on a single LAN segment. One of the primary benefits
of LAN switches with VLANs is that they can be used to effectively contain broadcast traffic
and manage traffic flows. A router is required for traffic to traverse between VLANs. Although
routers are almost always part of a network where VLANs exist, a switch also prevents broad-
cast traffic from one VLAN from affecting another VLAN.

Figure 1-4 VLANs Allow for More Flexible Arrangements of Broadcast Domains

VLAN1 VLAN2

VLAN3

Traditional 80/20 Rule of Network Traffic


Ideally, end users with common interests or work patterns are placed in the same logical net-
work as the servers they access most. Most of the traffic within these logical networks is con-
tained on the local LAN segment. This simple task effectively minimizes the load on the
network backbone.
As shown in Figure 1-5, the 80/20 rule (pertinent through much of the 1990s) states that in
a properly designed network, 80 percent of the traffic on a given network segment is local.
No more than 20 percent of the network traffic should move across the network’s backbone.
Backbone congestion indicates that traffic patterns are not meeting the 80/20 rule. In this
1439_CCNP_3.book Page 8 Monday, November 15, 2004 10:35 AM

8 Chapter 1: Campus Networks and Design Models

case, rather than adding switches or replacing hubs with switches, network administrators can
improve network performance by doing one of the following:
■ Moving resources such as applications, software programs, and files from one server to
another to contain traffic locally within a workgroup
■ Moving users logically, if not physically, so that the workgroups more closely reflect
the actual traffic patterns
■ Adding servers so that users can access them locally without having to cross the
backbone

Figure 1-5 The 80/20 Rule of Network Traffic

VLAN2 80+%
80+% VLAN1
Local Traffic Local Traffic

VLAN3
80+% 20%
Local Traffic Remote Traffic

The New 20/80 Rule of Network Traffic


In today’s networks, traffic patterns are moving toward what is called the 20/80 model (see
Figure 1-6). In the 20/80 model, only 20 percent of traffic remains local to the workgroup
LAN, and 80 percent of the traffic leaves the local network.
Two factors have contributed to these changing traffic patterns:
■ The Internet—With web-based computing and Internet applications, a PC can be a
tool for both publishing and accessing information. So information can now come from
anywhere in the network, potentially creating massive amounts of traffic crossing sub-
net boundaries. Users hop transparently between servers across the enterprise by using
hyperlinks, without having to worry about where the data is located.
■ Server farms—The second factor leading to the decline of local-centric networks is
the move toward server consolidation. Enterprises are deploying centralized server
farms for security purposes, ease of management, and reduced cost of ownership. All
traffic from the client subnets to these servers must travel across the campus backbone.
1439_CCNP_3.book Page 9 Monday, November 15, 2004 10:35 AM

Overview of a Campus Network 9

Figure 1-6 The 20/80 Rule of Network Traffic

VLAN2 20%
20% VLAN1
Local Traffic Local Traffic

80+%
Remote Traffic

VLAN3
20%
Local Traffic

However, this change in traffic patterns requires the Layer 3 performance to approximate the
Layer 2 performance. Because routing is a CPU-intensive process, this Layer 3 processing
can create network bottlenecks. This increased reliance on Layer 3 processing is an important
factor driving the continued increase in requirements on campus networks.

Key Requirements of the Evolving Campus Structure


The key requirements placing pressure on the emerging campus designs are as follows:
■ Fast convergence—This requirement stipulates that the network must be able to adapt
very quickly to changes in the network topology, such as failed links and insertion of
new devices on the network. Fast convergence becomes even more critical as the cam-
pus network grows in geographic scope.
■ Deterministic paths—This requirement allows a device or administrator to make a
decision based on the desirability of a given path to a destination for certain applica-
tions or user groups.
■ Redundancy—This requirement specifies that a mechanism, such as redundant links,
devices, or modules, is in place to ensure that the network is operational at all times.
■ Scalable—This requirement states that as the network grows and new applications are
added, the infrastructure must be able to handle the increased traffic demands.
■ Centralized applications—This requirement dictates that centralized applications
must be available to support most or all users on the network. The server farm is in a
centralized location using the same hop count for each area of the network.
■ The new 20/80 rule—This requirement focuses on the shift in traditional traffic
patterns.
1439_CCNP_3.book Page 10 Monday, November 15, 2004 10:35 AM

10 Chapter 1: Campus Networks and Design Models

■ Multiprotocol support—This requirement specifies that campus networks must be


able to support multiprotocol environments, such as mixed Internet Protocol (IP) and
Internetwork Packet Exchange (IPX) environments.
■ Multicasting—This requirement demands that campus networks be able to support IP
multicast traffic in addition to IP unicast traffic.

Evolving Campus Structure


Increased user demands and complex applications have forced network designers to focus on
the network’s actual traffic patterns. Networks can no longer be divided into subnetworks
based only on the number of users. The emergence of enterprise servers that run applications
serving all users also has a direct effect on the load across the network. A higher traffic load
across the entire network results in the need for more efficient routing and switching techniques.
In the new campus model, traffic patterns dictate the placement of the services required by
the end user. To service the local traffic, Layer 2 switches have moved to the edge of the net-
work and into the wiring closets. These switches connect end-user devices and servers into a
common workgroup. Services can be separated into three categories:
■ Local services
■ Remote services
■ Enterprise services
A local service is one in which the entities that provide the service reside on the same subnet
and, therefore, the same virtual network as the user. Local services remain in specific areas of
the network. Traffic to and from local services is confined to links between the server, the
switches, and the end users. Local traffic does not enter the network backbone or pass through
a router.
A remote service is an entity that might be geographically close to the end user but that is not
on the same subnet or VLAN as the user. Traffic to and from remote services might or might
not cross the backbone. Requests for the remote services have to cross broadcast domain
boundaries because these services are remote to the requesting end user. Therefore, switches
must connect to Layer 3 devices to allow for access to remote services.
Enterprise services are services common to all users. Examples of enterprise services are
e-mail, Internet access, and videoconferencing. Because all users need to access enterprise
services, these servers and services exist within a separate subnet placed close to the back-
bone. Because enterprise services exist outside the end user’s broadcast domain, Layer 3
devices are required to access these services. The enterprise services might or might not be
grouped by Layer 2 switches.
1439_CCNP_3.book Page 11 Monday, November 15, 2004 10:35 AM

Key Characteristics of Various Switching Technologies 11

Assuming a hierarchical design, placing the enterprise servers close to the backbone ensures
the same distance from each user. It also means that all traffic going to an enterprise server
indeed crosses the network backbone.

Interactive Media Activity Drag and Drop: Evolving Campus Structure


This activity helps you understand local, remote, and enterprise services.

Key Characteristics of Various Switching Technologies


Two primary factors govern a switched network’s success:
■ Availability
■ Performance
Other factors include
■ Reliability
■ Scalability
■ Cost
The range and variety of services now available on modern switches are extensive, can be
overwhelming, and will continue to evolve over time because these services are driven by
customer needs. Focus on the core concepts of these technologies instead of expecting to
master each one. Many of these technologies will be replaced by completely independent
solutions in the coming years.

Overview
Modern networks should support data, voice, and video. This means the network devices
must support quality of service (QoS) and multicast technologies. QoS is needed to provide
acceptable levels of service to the end user. During periods of congestion, a QoS policy
ensures that certain types of traffic, defined by the network engineer, receive preferential
treatment over other types of traffic. In addition, QoS is not effective when chronic conges-
tion exists. QoS is better suited to handle occasional periods of congestion.
The network should also have a high-speed, reliable backbone. This means that one or more
switches need to support large capacities on the switch backplane and offer significant Giga-
bit Ethernet port densities.
The network should be scalable. This means having devices that can be upgraded without need-
ing to replace them with completely new equipment. Each switch purchased for the backbone
must have a chassis containing sufficient slots to reasonably support module upgrades over
1439_CCNP_3.book Page 12 Monday, November 15, 2004 10:35 AM

12 Chapter 1: Campus Networks and Design Models

time that are appropriate for the network. Backbone switches should have nonblocking back-
planes. A switch that supports high-speed switching at Layer 3 to Layer 7 is needed. This
means that the switches should support technologies such as Cisco Express Forwarding (CEF).
Finally, the network should have redundancy. This means that the switches need to support
such features as Hot Standby Router Protocol (HSRP), Internet Control Message Protocol
(ICMP) Router Discovery Protocol (IRDP), VLAN Trunking Protocol (VTP), trunking, chan-
neling, Internet Group Management Protocol (IGMP), Cisco Group Management Protocol
(CGMP), and Spanning Tree Protocol (STP).
These features are just some of the considerations you need to keep in mind when purchasing
a switch. Modern switches support a variety of other features.
The OSI model provides a convenient way to describe processes that take place in a network-
ing environment. Each layer in the OSI model relates to a set of specific functions. This book
focuses on Layers 2, 3, and 4 of the OSI model.
Protocols normally can be categorized into one or more of the OSI layers. Each protocol
exchanges information called protocol data units (PDUs) between peer layers of network
devices. Table 1-1 shows the specific name for each PDU at each layer and the device type
that traditionally processes the PDU.

Table 1-1 Generic Names for PDUs at Each OSI Layer

Layer PDU Type Device Type

Data link (Layer 2) Frames Layer 2 switch or bridge

Network (Layer 3) Packets Router, Layer 3 switch

Transport (Layer 4) Segments Router or server (TCP or UDP port),


Layer 4 switch

The underlying layer services each protocol peer layer. For example, TCP segments are
encapsulated in Layer 3 packets, which are encapsulated in Layer 2 frames. A layer-specific
device processes only those PDUs for which it is responsible by inspecting the PDU header.
Each device treats the higher-level information as payload. For example, a switch processes
Layer 2 information and considers the Layer 3 information payload and merely forwards it
without processing it.
Switches are available that can make decisions based on PDU header information at Layers 2,
3, and 4. Content service switches, such as the Cisco CSS 11800, make switching decisions
based on Layer 2 to Layer 7 header information.
1439_CCNP_3.book Page 13 Monday, November 15, 2004 10:35 AM

Key Characteristics of Various Switching Technologies 13

Layer 2 Switching
Bridges and switches analyze incoming frames, make forwarding decisions based on infor-
mation contained in the frames, and forward the frames toward the destination. Upper-layer
protocol transparency is a primary advantage of both bridging and switching. Because both
bridges and switches operate at the data link layer, they are not required to examine upper-
layer information. Bridges also can filter frames based on any Layer 2 fields.
Although bridges and switches share most relevant attributes, several distinctions differentiate
these technologies. Switches are significantly faster because they switch in hardware. Switches
also can support higher port densities than bridges. Some switches support cut-through
switching, which reduces latency and delays in the network by processing only the MAC
address portion of the frame. Bridges support only store-and-forward traffic switching (where
the entire frame is processed before forwarding). The main differences are that bridges per-
form switching through software, as opposed to hardware, and switches have a higher port
density.
Layer 2 switching is basically hardware-based bridging, as shown in Figure 1-7. In a switch,
frame forwarding is handled by specialized hardware called Application-Specific Integrated
Circuits (ASICs). The ASIC technology engineered for switches allows for scalability up to
gigabit speeds, with low latency at costs significantly lower than Ethernet bridges.

Figure 1-7 Layer 2 Switching Is Hardware-Based Bridging

7 • Hardware-Based Bridging
• Wire-Speed Performance
• High-Speed Scalability
6 • Low Latency
• MAC Address
• Low Cost
5

2 Data Link

Layer 2 switches let network managers increase bandwidth without adding complexity to the
network. Layer 2 data frames consist of both control information, such as MAC addresses,
and end-user content. At Layer 2, no modification of the frame control information is
required when moving between similar Layer 1 interfaces, such as Ethernet and Fast
1439_CCNP_3.book Page 14 Monday, November 15, 2004 10:35 AM

14 Chapter 1: Campus Networks and Design Models

Ethernet. However, changes to control information might occur when bridging between
unlike media types, such as Fiber Distributed Data Interface (FDDI), Asynchronous Transfer
Mode (ATM), and Ethernet.
Workgroup connectivity and network segmentation are the two primary uses for Layer 2
switches. The high performance of a Layer 2 switch allows for network designs that signifi-
cantly decrease the number of hosts per physical segment, creating a flatter design with more
segments in the campus network.
Despite the advantages of Layer 2 switching, it still has all the same characteristics and limi-
tations of legacy bridging. Broadcast domains are unaffected by the incorporation of Layer 2
switches. The same scaling and performance issues exist as in the large bridged networks of
the past. The broadcast and multicast radius increases with the number of hosts, and broad-
casts are still propagated across the network. Also, STP issues are proportional to the size of
the Layer 2-only network.
It is evident that Layer 3 functionality is still needed within the network. The next section
introduces Layer 3 switching.

Layer 3 Switching
Layer 3 switching is hardware-based routing, as illustrated in Figure 1-8.

Figure 1-8 Layer 3 Switching Is Hardware-Based Routing

7 • Hardware-Based Packet Forwarding


• High-Performance Packet Switching
• High-Speed Scalability
6 • Low Latency
• Lower Per-Port Cost
• Flow Accounting
• Security
5 • QoS

3 Network

The packet forwarding is handled by specialized hardware ASICs. The goal is to capture the
speed of switching and the scalability of routing. A Layer 3 switch acts on a packet in the
same way a traditional router does:
■ Determines the forwarding path based on Layer 3 information
1439_CCNP_3.book Page 15 Monday, November 15, 2004 10:35 AM

Key Characteristics of Various Switching Technologies 15

■ Validates the integrity of the Layer 3 header via checksum


■ Verifies packet expiration and updates accordingly
■ Processes and responds to any option information
■ Updates forwarding statistics in the Management Information Base (MIB)
■ Applies security controls if required
■ Implements QoS
The primary difference between the packet-switching operation of a router and a Layer 3
switch lies in the physical implementation. In general-purpose routers, microprocessor-based
engines typically perform software-based packet switching. A Layer 3 switch performs
packet switching with hardware. Because it is designed to handle high-performance LAN
traffic, a Layer 3 switch can be placed anywhere within the network, offering a cost-effective
alternative to the traditional router.

Layer 4 Switching
Layer 4 switching refers to Layer 3 hardware-based routing that accounts for Layer 4 control
information, as shown in Figure 1-9. Information in packet headers typically includes Layer 3
addressing, the Layer 3 protocol type, and more fields relevant to Layer 3 devices, such as
Time-To-Live (TTL) and checksum. The packet also contains information relevant to the
higher layers within the communicating hosts, such as the protocol type and port number.

Figure 1-9 Layer 4 Switching Is Hardware-Based, or Wire-Speed Routing That Accounts for Layer 4
Control Information

• Based on Layer 3 and Layer 4


• Based on Application-Related
7 Information
• TCP Fields
• UDP Fields
6 • QoS
• Granular Traffic Control

4 Transport

The term Layer 4 switching is sometimes used to describe switching frames based on flows
characterized by a combination of source/destination MAC addresses, IP addresses, and port
1439_CCNP_3.book Page 16 Monday, November 15, 2004 10:35 AM

16 Chapter 1: Campus Networks and Design Models

numbers. One advantage of Layer 4 switching is that it allows QoS to be applied to traffic.
QoS is typically applied to classes of traffic defined by port numbers, so it can be said to
provide application-based prioritization.
Routers can control traffic based on Layer 4 information. One method of controlling Layer 4
traffic is by using extended access lists. Another method of providing Layer 4 accounting of
flows, NetFlow switching, is used on the Cisco 7200 and 7500 router platforms and the
Catalyst 5000 and 6000 family switches.
Finally, when performing Layer 4 functions, a switch reads the TCP and UDP fields in the
headers to determine what type of information the packet is carrying. The network manager
can program the switch to prioritize traffic by application. This function allows network man-
agers to define a QoS for end users. When used for QoS purposes, Layer 4 switching might
mean that a videoconferencing application is granted more bandwidth than an e-mail message
or FTP packet.
Layer 4 switching is necessary if the organization’s policy dictates granular control of traffic
by application or if the organization requires accounting of traffic itemized in terms of appli-
cations. However, it should be noted that switches performing Layer 4 switching need the
capability to identify and store large numbers of forwarding-table entries, especially if the
switch is within the core of an enterprise network. Many Layer 2 and Layer 3 switches have
forwarding tables that are sized in proportion to the number of network devices.
With Layer 4 switches, the number of network devices must be multiplied by the number of
different application protocols and conversations in use in the network. Thus, the size of the
forwarding table can grow quickly as the numbers of end devices and types of applications
increase. This large table capacity is essential to creating a high-performance switch that
supports wire-speed Layer 4 forwarding of traffic.

Multilayer Switching
The term multilayer switching is used for two distinct things. On one hand, multilayer switch-
ing is a general network design term used to refer to hardware-based PDU header rewrite of
PDUs based on information specific to one or more OSI layers. On the other hand, multilayer
switching when referenced by the acronym MLS refers to a specific technology employed by
various Cisco devices to perform wire-speed PDU header rewrites.
Multilayer switching combines Layer 2 switching, routing, and caching of Layer 4 port infor-
mation, as shown in Figure 1-10. Multilayer switching provides wire-speed (hardware-based)
switching enabled by ASICs within a switch, which share the duties normally assumed by
the CPU.
1439_CCNP_3.book Page 17 Monday, November 15, 2004 10:35 AM

Key Characteristics of Various Switching Technologies 17

Figure 1-10 Multilayer Switching

7 • Combines Functionality of:


• Layer 2 Switching
• Layer 3 Routing Functionality
6 • Layer 4 Caching of Port Information
• High-Speed Scalability
• Low Latency
5

4 Transport

3 Network

2 Data Link

With MLS, the switch caches information about a given flow of data through the switch, NOTE
inspecting the PDU header information of the first frame in the flow and switching the The term flow loosely
describes a stream of
remaining data at wire speed based on the information from the first frame (see Figure 1-11).
data between two end-
This explains the phrase used with MLS—“route once, switch many.” The figure shows the points across a network.
pertinent Layer 2 and Layer 3 information used as the frame moves from Host A to Host B. The flow can be based
on Layer 2 and 3 infor-
MLS stores this information to circumvent the router for subsequent frames in the same flow. mation or a combina-
tion of Layer 2, 3, and 4
Figure 1-11 “Route Once, Switch Many” Switching Mechanism Provided by MLS information.

Fast Ethernet 1/0

int fa 1/0.1 int fa 1/0.2


IP Address: 10.1.1.1 IP Address: 10.1.2.1
MAC Address: 00-00-0C-11-11-11 MAC Address: 00-00-0C-22-22-22
VLAN: 1 (Black) VLAN: 2 (Blue)

1/1
Host A Host B

2/1 3/1

Black Blue

VLAN: 1 VLAN: 2
IP Address: 10.1.1.10 IP Address: 10.1.2.20
MAC Address: 00-AA-00-11-11-11 MAC Address: 00-AA-00-22-22-22
1439_CCNP_3.book Page 18 Monday, November 15, 2004 10:35 AM

18 Chapter 1: Campus Networks and Design Models

Quality of Service (QoS)


Quality of service (QoS) refers to a network’s capability to provide better service to selected
network traffic. QoS maps well to the multilayer campus design. Packet classification is a
multilayer service that is applied at the wiring closet switch, the ingress point to the network.
Table 1-2 outlines the QoS options available with Cisco IOS software.

Table 1-2 QoS Options Available with Cisco IOS Software

Protocol Group Protocol

QoS Classification and Marking Distributed Committed Access Rate (DCAR)


Multiprotocol Label Switching (MPLS) EXP bit

QoS Configuration and Monitoring Network-Based Application Recognition (nBAR)

QoS Congestion Avoidance Random Early Detection (RED)


Weighted RED (WRED)
Distributed WRED (D-WRED)
Flow-based WRED

QoS Congestion Avoidance Low-Latency Queuing (LLQ)


Distributed Low Latency Queuing
Weighted Fair Queuing (WFQ)
Class-Based Weighted Fair Queuing (CBWFQ)
First-in, first-out (FIFO) queuing
IP RTP priority
Priority Queuing (PQ)

QoS Link Efficiency Mechanisms Multilink Point-to-Point Protocol (MLPPP)

QoS Policing and Shaping Committed Access Rate (CAR)


CAR rate limiting

QoS Signaling Resource Reservation Protocol (RSVP)

QoS for voice or video over IP consists of providing minimal packet loss and minimal delay
so that voice/video quality is unaffected by conditions in the network. A brute-force solution
is to simply provide sufficient bandwidth at all points in the network to minimize packet loss
and queuing delay. A better alternative is to apply congestion management and congestion
avoidance at oversubscribed points in the network. Most modern Layer 3 and above switches
support configuration options for congestion management and congestion avoidance.
1439_CCNP_3.book Page 19 Monday, November 15, 2004 10:35 AM

Key Characteristics of Various Switching Technologies 19

A reasonable design goal for end-to-end network delay for voice over IP (VoIP) is 150 milli-
seconds. Providing a separate outbound queue for real-time traffic is sufficient to guarantee
low delay for voice at campus speeds. Bursty traffic, such as file transfers, is placed in a dif-
ferent queue from real-time traffic. Low-latency queuing (LLQ) is the preferred method for
queuing in this context, giving priority to voice traffic while data traffic is typically governed
by weighted fair queuing. Auxiliary VLANs also provide an effective means for optimizing
voice traffic in a campus LAN. Another option for achieving low packet loss and high
throughput in any queue that experiences bursty data traffic flow is Weighted Random Early
Detection (WRED). Note that WRED affects only TCP traffic, so it has no effect on voice
traffic, which is UDP-based.
QoS plays a significant role in designing a modern switched network. With VoIP and stream-
ing video now commonplace and videoconferencing on the rise, it is important to understand
the particular demands of these types of traffic on the network and how to design the switched
network to optimally support it.

Multicast
Multicast is becoming an integral part of network design, although it poses one of the greatest
challenges to network engineers. Multicast is configured so that one-to-many and many-to-
many communication with voice and video take place. Applications such as Cisco IP/TV
depend on multicast functionality in the campus network.
A good multicast network design is fundamentally important for any enterprise that wants to
enjoy the many benefits of multicast technology. If the devices in the network are not specifi-
cally configured for multicast, this precludes the possibility of end users receiving multicast
streams from multicast servers. In addition, the network might be subject to indiscriminate
flooding of multicast traffic in portions of the network, which might result in loss of services.
Multicast control is extremely important because of the large amount of traffic involved when
several high-bandwidth multicast streams are provided, as illustrated in Figure 1-12. The
multilayer campus design is ideal for the control and distribution of IP multicast traffic. Layer 3
multicast control is provided primarily by the Protocol-Independent Multicast (PIM) proto-
col. Multicast control at the wiring closet is provided by Internet Group Management Protocol
(IGMP) and IGMP Snooping or Cisco Group Multicast Protocol (CGMP).
At the wiring closet, IGMP Snooping and CGMP (detailed in Chapter 7, “Cisco AVVID”) are
multilayer services that prune multicast traffic between switch ports and directly connected
routers. Without IGMP Snooping or CGMP, multicast traffic would flood all switch ports.
IGMP itself prunes unnecessary multicast traffic on router interfaces connected to client
workstations.
1439_CCNP_3.book Page 20 Monday, November 15, 2004 10:35 AM

20 Chapter 1: Campus Networks and Design Models

Figure 1-12 Multicasting Optimizes Bandwidth Utilization

Example: Audio Streaming


Multicast All Clients Listening to the Same 8 Kbps Audio
Unicast

0.8
0.6
Traffic
Mbps 0.4
0.2
0
1 20 40 60 80 100
Clients

• Enhanced Efficiency: Controls Network Traffic and Reduced Server and CPU Loads
• Optimized Performance: Eliminates Traffic Redundancy
• Distributed Applications: Makes Multipoint Applications Possible

In PIM sparse mode (also discussed in Chapter 7), a rendezvous point is used as a broker or
proxy for multicast traffic. A design goal of multicast networks is to place the rendezvous
point and backup rendezvous point(s) to affect the shortest path. If this is accomplished, there
is no potential for suboptimal routing of multicast traffic. Ideally, the rendezvous point and
optional backups should be placed on the Layer 3 distribution switch in the server farm close
to the multicast sources. If redundant rendezvous points are configured on routers instead of
switches, recovery in the case of one rendezvous point going down is more CPU-intensive.
In any case, it is critical that network design take into account multicast functionality. The
switches should support IGMP Snooping or CGMP, as well as the various PIM modes and
Multicast Source Discovery Protocol (MSDP), a relatively new protocol that can, among
other things, enhance dynamic rendezvous point selection.

Hierarchical Design Model for Campus Networks


A hierarchical network design includes the following three layers, each of which provides
different functionality:
■ The core layer, which provides optimal connectivity between distribution blocks
■ The distribution layer, which provides policy-based connectivity
■ The access layer, which provides access layer aggregation and Layer 3 and Layer 4
services
Figure 1-13 shows a high-level view of the various aspects of a hierarchical network design.
1439_CCNP_3.book Page 21 Monday, November 15, 2004 10:35 AM

Key Characteristics of Various Switching Technologies 21

Figure 1-13 Hierarchical Design Model: The Core, Distribution, and Access Layers Comprise the
Campus Network

Core Layer

Distribution Layer

Access Layer

The Core Layer


The core layer is a high-speed switching backbone and should be designed to switch packets
as fast as possible between all distribution layer devices in the campus network. The core
layer should not perform any packet manipulation (such as filtering with access lists) that
would slow down the switching of packets. It is now common for the core layer to be a pure
Layer 3 switched environment, which means that VLANs and VLAN trunks (discussed in
Chapter 2, “VLANs and VTP”) are not present in the core. It also means that spanning tree
loops (discussed in Chapter 3, “Spanning Tree Protocol (STP)”) are avoided in the core.

The Distribution Layer


The network’s distribution layer divides the access and core layers and helps define and dif-
ferentiate the core. This layer provides a boundary definition and is where packet manipula-
tion takes place. In the campus environment, the distribution layer can serve several
functions:
■ Address or area aggregation
■ Departmental or workgroup access connectivity to the backbone
■ Broadcast/multicast domain definition
1439_CCNP_3.book Page 22 Monday, November 15, 2004 10:35 AM

22 Chapter 1: Campus Networks and Design Models

■ Inter-VLAN routing
■ Any media transitions that need to occur
■ Security
In the noncampus environment, the distribution layer can be a redistribution point between
routing domains or the demarcation between static and dynamic routing protocols. It can also
be the point at which remote sites access the corporate network. The distribution layer can be
summarized as the layer that provides policy-based connectivity.
Packet manipulation, filtering, route summarization, router filtering, route redistribution,
inter-VLAN routing, policy routing, and security are some of the primary roles of the
distribution layer.

The Access Layer


The access layer is the point at which local end users are allowed into the network. This layer
can also use access lists to further optimize the needs of a particular set of users. In the cam-
pus environment, access layer functions can include
■ Shared bandwidth
■ Switched bandwidth
■ MAC layer filtering
■ Microsegmentation
In the noncampus environment, the access layer can give remote sites access to the corporate
network via wide-area technologies, such as Public Switched Telephone Network (PSTN),
Frame Relay, Integrated Services Digital Network (ISDN), digital subscriber line (xDSL),
and leased lines.
It is often mistakenly thought that the three layers (core, distribution, and access) must exist
as clear and distinct physical entities, but this does not have to be the case. The layers are
defined to aid successful network design and to represent functionality that must exist in
a network. How the layers are implemented depends on the needs of the network being
designed. It is important to remember that for a network to function optimally and maintain
scalability as growth occurs, hierarchy must be maintained.

Interactive Media Activity Drag and Drop: Hierarchical Design Model for
Campus Networks
This activity helps you understand the core, distribution, and access layers.
1439_CCNP_3.book Page 23 Monday, November 15, 2004 10:35 AM

Building-Block Approach 23

Building-Block Approach
Network building blocks, as shown in Figure 1-14, can be any one of the following funda-
mental campus elements or contributing variables:
■ Campus elements:
— Switch block
— Core block
■ Contributing variables:
— Server block
— WAN block
— Mainframe block
— Internet connectivity

Figure 1-14 Network Building Blocks Enable a Hierarchical Multilayer Campus Network Design

Switch Block
Building A Building B Building C

Core Block
Token
Ring

WAN Block

Mainframe Block

Server Block
1439_CCNP_3.book Page 24 Monday, November 15, 2004 10:35 AM

24 Chapter 1: Campus Networks and Design Models

The Switch Block


The switch block contains a set of logically grouped switches and associated network devices.
This set provides a balance of Layer 2 and Layer 3 services. Although the current generation
of LAN switches has replaced bridges and shared-media hubs, LAN switches are not replace-
ments for Layer 3 devices. Therefore, the switch block consists of both switch and router
functionality.
Layer 2 switches in the wiring closets connect users to the network at the access layer and
provide dedicated bandwidth to each port. The access layer devices merge into one or more
distribution layer devices. The distribution device provides Layer 2 connectivity between
access switches and acts as a central connection point for all the switches in the wiring closets.
The distribution layer also provides Layer 3 functionality, which supports routing and net-
working services. The distribution layer shields the switch block against failures in other
parts of the network, as shown in Figure 1-15.

Figure 1-15 The Distribution Layer Switches Prevent Propagation of Network Problems, Such as
Broadcast Storms, to Other Switch Blocks

Switch Block 1 Switch Block 2


Broadcast
Access Layer Access Layer Storm

Distribution Layer Distribution Layer

The distribution device can be one of the following:


■ A switch and external router combination
■ A multilayer switch
1439_CCNP_3.book Page 25 Monday, November 15, 2004 10:35 AM

Building-Block Approach 25

If the switch block experiences a broadcast storm, the router prevents the storm from propa-
gating into the core and across the rest of the network. Of course, this assumes that the Cisco-
recommended design using local VLANs is in effect. Each block is protected from the other
blocks when failures occur. However, the switch block, in which the broadcast storm occurs,
still experiences network problems until the device generating the broadcasts is found and
removed from the network.
A switch might support one or more subnets. Remember that a subnet must reside within one
broadcast domain. This means that all stations residing in or ports configured on the same
VLAN are assigned network addresses within the same subnet.
The broadcast-isolation feature of VLANs is the characteristic that allows VLANs to be iden-
tified with subnets. For example, the IP ARP propagates only within the VLAN of the origi-
nating request. All subnets terminate on Layer 3 devices, such as a router or route processor.
To connect to devices in other VLANs, the frame must traverse a Layer 3 device. Using this
model, VLANs should not extend beyond the distribution switch.
Access devices have redundant connections, or uplinks, to the distribution switch to maintain
resiliency. STP allows these redundant links to exist while preventing undesirable loops in the
switch block. STP terminates at the boundary of the switch block.

Scaling the Switch Block


Although the size of a switch block is flexible, certain factors limit its size. How many
switches collapse into the distribution layer depends on several factors:
■ Different types and patterns of traffic
■ Amount of Layer 3 switching capacity at the distribution layer
■ Number of users per access layer switch
■ Extent to which subnets need to traverse geographic locations within the network
■ Size to which the spanning-tree domains should be allowed to grow
Sizing the switch block involves two main factors:
■ Traffic types and behavior
■ Size and number of workgroups
A switch block is too large if
■ A traffic bottleneck occurs in the routers at the distribution layer because of intensive
CPU processing resulting from policy-based filters
■ Broadcast or multicast traffic slows down the switches and routers
1439_CCNP_3.book Page 26 Monday, November 15, 2004 10:35 AM

26 Chapter 1: Campus Networks and Design Models

Building the Core Block


A core is required when two or more switch blocks exist. The core block is responsible for
transferring cross-campus traffic without any processor-intensive operations. All the traffic
going to and from the switch blocks, server blocks, the Internet, and the WAN must pass
through the core. Traffic going from one switch block to another also must travel through the
core. It follows that the core handles much more traffic than any other block. Therefore, the core
must be able to pass the traffic to and from the blocks as quickly as possible.
Different technologies such as frame, packet, or cell-based technologies can be used in the
core, depending on the organization’s specific needs. The examples shown here use an Ether-
net core. Because the distribution switch provides Layer 3 functionality, individual subnets
connect all distribution and core devices, as shown in Figure 1-16.

Figure 1-16 The Core Layer Switches Prevent Propagation of Network Problems, Such as
Broadcast Storms, to Other Switch Blocks

The core can consist of one subnet. However, for resiliency and load balancing, at least two
subnets are configured. Because VLANs terminate at the distribution device, core links are
not trunk links, and traffic is routed across the core. Therefore, core links do not carry multiple
VLANs per link. One or more switches make up a core subnet. It is strongly recommended
that a minimum of two devices be present in the core to provide redundancy. The core block
can consist of high-speed Layer 2 devices or Layer 3 devices.
1439_CCNP_3.book Page 27 Monday, November 15, 2004 10:35 AM

Building-Block Approach 27

At a minimum, the media between the distribution switches and the core layer switches
should be capable of supporting the amount of load handled by the distribution switch. Also,
at a minimum, the links between core switches in the same core subnet should be sufficient to
switch the aggregate amount of traffic with respect to the input aggregation switch traffic. The
design of the core should consider average link utilization while allowing for future traffic
growth.
There are two basic core designs:
■ Collapsed core
■ Dual core

Collapsed-Core Design
The collapsed core, shown in Figure 1-17, is characterized by a consolidation of the distribu-
tion and core-layer functions into one device. A collapsed-core design is prevalent in small
campus networks. Although the functions of each layer are contained in the same device,
the functionality remains distinct. In a collapsed-core design, each access layer switch has a
redundant link to the distribution layer switch. Each access layer switch might support more
than one subnet. However, all subnets terminate at Layer 3 ports on the distribution switch.

Figure 1-17 The Collapsed Core Is Common in Small and Medium Campus Networks

Switch Block 1 Switch Block 2


Access Layer Access Layer

Core
Connectivity

Distribution/Core Layer Distribution/Core Layer


1439_CCNP_3.book Page 28 Monday, November 15, 2004 10:35 AM

28 Chapter 1: Campus Networks and Design Models

Redundant uplinks provide Layer 2 resiliency between the access and distribution switches.
Spanning Tree Protocol blocks the redundant links to prevent loops. Redundancy is provided
at Layer 3 by the dual distribution switches with HSRP, providing transparent default gateway
operations for IP. If the primary routing process fails, connectivity to the core is maintained.

Dual-Core Design
A dual-core configuration is necessary when two or more switch blocks exist and redundant
connections are required. Figure 1-18 shows a dual-core configuration in which the core con-
tains only Layer 2 switches in the backbone.

Figure 1-18 The Dual Core Is Common When the Campus Network Contains Several Switch Blocks

Switch Block 1 Switch Block 2


Access Layer Access Layer

Core
Connectivity

Distribution/Core Layer Distribution/Core Layer

Subnet A Core Subnet B


Block

A dual-core topology provides two equal-cost paths and twice the bandwidth. Each core
switch carries a symmetrical number of subnets to the Layer 3 function of the distribution
device. Each switch block is redundantly linked to both core switches, allowing for two dis-
tinct, equal path links. If one core device fails, convergence is not an issue, because the rout-
ing tables in the distribution devices already have an established route to the remaining core
1439_CCNP_3.book Page 29 Monday, November 15, 2004 10:35 AM

Building-Block Approach 29

device. The Layer 3 routing protocol provides the link determination across the core, and
HSRP provides quick failover determination. Spanning Tree Protocol is not needed in the
core because there are no redundant Layer 2 links between the core switches.

Layer 2 and Layer 3 Backbone Scaling


Switched Layer 2 Ethernet cores are very cost-effective, and they provide high-performance
connectivity between switch blocks. The classic design model has several switch blocks, each
supporting Layer 2 devices in a wiring closet that terminate into a Layer 3 device. A core
composed of Layer 2 devices connects the Layer 3 distribution devices.
Spanning Tree Protocol represents a practical limit to the scale of a Layer 2 switched back-
bone. As the number of core devices increases, there is a corresponding increase in the num-
ber of links from the distribution switches to maintain redundancy. Because routing protocols
dictate the number of equal-cost paths, the number of independent core switches is limited.
Interconnecting the core switches creates bridging loops. Introducing Spanning Tree Protocol
into the core compromises the high-performance connectivity between switch blocks. Ideally,
Layer 2 switched backbones consist of two switches with no spanning-tree loops in the
topology.
The Layer 2 switched backbone provides redundancy without any spanning-tree loops. Because
the two core switches are not linked in Figure 1-19, loops do not occur. Each distribution
switch in every switch block has a separate path to each core switch. The dual connection
between the core and distribution device provides each Layer 3 device with two equal-cost
paths to every other router in the campus.

Figure 1-19 Physical Loops Are Avoided in a Layer 2 Core if the Backbone Switches Are Not
Physically Connected

Core Layer

Distribution Layer

VLAN 51
VLAN 52 Access Layer
1439_CCNP_3.book Page 30 Monday, November 15, 2004 10:35 AM

30 Chapter 1: Campus Networks and Design Models

Note that a Layer 2 switched backbone does not preclude connecting the core switches, as
long as Spanning Tree Protocol is carefully configured to logically prevent any loops. The
advantage of having the core switches physically connected in a Layer 2 backbone is that
failover maintains connectivity between switch blocks when uplinks from distribution switches
in independent switch blocks fail. The trade-off is increased complexity in Layer 2 configuration
and probably is not worth the trouble.
Most of the designs successfully follow the Layer 2/Layer 3/Layer 2 model. However, there
are designs where the Layer 2/Layer 3/Layer 3 model is advantageous.
Figure 1-20 shows a Layer 3 core.

Figure 1-20 A Layer 3 Core Is Standard in Modern Campus Networks

Implement a Layer 3 core for the following reasons:


■ Fast convergence
■ Automatic load balancing
■ Elimination of peering problems

Fast Convergence
As the number of switch blocks and servers increases, each distribution layer device must be
connected to the core. Because there is a limit to the number of switch blocks in a dual Layer 2
core, increasing the number of connections means increasing the number of core devices. To
maintain redundancy, the core devices must be connected. Bridging loops appear when you
interconnect Layer 2 devices. To eliminate bridging loops in the core, Spanning Tree Protocol
must be enabled. Unfortunately, Spanning Tree Protocol has a convergence time of more than
50 seconds. If the network core experiences a fault, Spanning Tree Protocol convergence can
disable the core for more than 1 minute.
1439_CCNP_3.book Page 31 Monday, November 15, 2004 10:35 AM

Building-Block Approach 31

If Layer 3 devices are implemented in the core, Spanning Tree Protocol is unnecessary. In
this design, routing protocols are used to maintain the network topology. Convergence for
link-state routing protocols takes from 5 to 10 seconds, depending on the routing protocol.

Automatic Load Balancing


Load balancing allows for a traffic-distribution pattern that best uses the multiple links that
provide redundancy. With multiple, interconnected Layer 2 devices in the core, the route for
using more than one path must be individually selected. The links must then be manually
configured to support specific VLAN traffic. With Layer 3 devices in the core, routing proto-
cols can be used to load-balance over multiple equal-cost paths.

Elimination of Peering Problems


Another issue with the Layer 2 core in a very large network is that of router peering. Router
peering mandates that the routing protocol running in a router maintain state and reachability
information for neighboring routers. In this scenario, each distribution device becomes a peer
with every other distribution device in the network. Scalability becomes an issue in the con-
figuration because each distribution device has to maintain state for all other distribution
devices.
By implementing Layer 3 devices in the core, a hierarchy is created, and the distribution
device is not considered a peer with all other distribution devices. This type of core might
appear in very large campus networks where the network supports more than 100 switch
blocks.

Performance and Cost Issues


Implementing Layer 3 devices in the core can be expensive, although relatively much less so
than in the past. As stated earlier, the main purpose of the core is to move packets as quickly
and efficiently as possible. Although Layer 3 devices support switching of routed protocols,
both performance and equipment costs weigh in heavily as design considerations.

Advantages of the Building-Block Approach


As shown so far, the implementation of a building-block approach and hierarchical model has
many advantages, including redundancy, scalability, loop-free topologies, fast convergence,
and load balancing. The examples in Figures 1-21, 1-22, and 1-23 illustrate these advantages.
1439_CCNP_3.book Page 32 Monday, November 15, 2004 10:35 AM

32 Chapter 1: Campus Networks and Design Models

Figure 1-21 A Campus Network Operating Normally

North Building South Building


M P

M2 M1 P2 P1

A B C D

X Y

Figure 1-22 Spanning Tree Protocol Provides Redundancy: If One Access Uplink Fails, a Second
Uplink Immediately Takes Over

North Building South Building


M P

M2 M1 P2 P1

A B C D

X Y
1439_CCNP_3.book Page 33 Monday, November 15, 2004 10:35 AM

Building-Block Approach 33

Figure 1-23 Failover Takes Place Via Spanning Tree Protocol or Dynamic Routing if an Uplink
Between a Distribution Switch and Core Switch Fails, Depending on Whether VLAN
Trunks or Routed Links Connect the Distribution and Core Layers

North Building South Building

M P

M2 M1 P2 P1

A B C D

X Y

In the sample network, two buildings have an access switch on each floor and redundant con-
nections to a distribution layer switch. Each distribution layer switch has redundant connections
into the network core.
In Figure 1-21, notice the flow of traffic from host M to host P. Suppose there is a port failure
in the access switch. Notice in Figure 1-22 how the switch immediately chooses an alternative
path. Assume in Figure 1-23 that the link between the distribution switch and the core switch
fails. As shown, the switches choose an alternative path through the core. The following
chapters explain how to configure these behaviors on the switch.

Interactive Media Activity Drag and Drop: Advantages of the Building-Block


Approach
This activity helps you understand the advantages of the building-block approach.
1439_CCNP_3.book Page 34 Monday, November 15, 2004 10:35 AM

34 Chapter 1: Campus Networks and Design Models

Small Campus Networks


Small campus networks, as shown in Figure 1-24, are the most common and are typically
contained within one building. In this design, it is not unusual to have a single multilayer
switch servicing the entire network. In most cases, cost effectiveness is the top priority, not
network redundancy. Requirements for this design typically include the following:
■ High performance for applications such as voice, video, and IP multicast
■ Support for applications based on Novell IPX, DECnet, AppleTalk, and Systems Net-
work Architecture (SNA)

Figure 1-24 Small Campus Networks Are the Most Prevalent Type of Network

Clients E/FE Attached

Layer 2
Access Switching
Layer

Backbone Layer 2/3


and Server Switching
Server Access
Farm
Servers FE/GE
Attached

A design solution that meets these requirements provides a high-performance, switched infra-
structure for a building-sized intranet with hundreds of networked devices. The network
backbone consists of a multilayer switch. The access layer switches provide connectivity to
clients and servers.

Medium Campus Networks


Medium campus networks, as shown in Figure 1-25, are characterized by a collapsed back-
bone, where the distribution layer and core layer merge. Medium campus networks are typically
contained within one large building or several buildings. In this design, high availability, per-
formance, and manageability are important. Additional requirements for this design typically
include the following:
■ High performance and availability for applications such as voice, video, and IP
multicast
■ Support for applications based on Novell IPX, DECnet, AppleTalk, and SNA
1439_CCNP_3.book Page 35 Monday, November 15, 2004 10:35 AM

Building-Block Approach 35

Figure 1-25 Medium Campus Networks Employ a Collapsed Backbone

Clients E/FE Attached

Access Layer 2
Layer Switching

Backbone Layer 3
and Server Switching
Distribution

Server Layer 2
Farm Switching

Servers
FE/GE Attached

The requirements for medium campus networks parallel those of small campus networks.
The major differences are the number of users and the importance of building redundancy
into medium campus networks.
A design solution that meets these requirements provides a high-performance, manageable
switched infrastructure for a campus intranet with more than 1000 networked devices. The
collapsed backbone uses Layer 3 switching, and network redundancy is provided for clients
and servers.

Large Campus Networks


Large campus networks have redundancy, high bandwidth, and well-defined core, distribu-
tion, and access layers. As Figure 1-26 illustrates, with typical designs, the buildings or dif-
ferent parts of the campus are connected across a high-performance switched backbone.
Network redundancy and high availability are provided at each layer, and a high-capacity
centralized server farm provides resources to the campus.
Businesses operating large campus networks are increasingly looking for infrastructure
upgrades to offer
■ Support for high-bandwidth applications such as voice, video, and IP multicast
■ Support for applications based on Novell IPX, DECnet, AppleTalk, and SNA
■ High availability, performance, and manageability for the company’s intranet
Large campus networks use Layer 2, Layer 3, or ATM backbone solutions to expand the
network.
1439_CCNP_3.book Page 36 Monday, November 15, 2004 10:35 AM

36 Chapter 1: Campus Networks and Design Models

Figure 1-26 Large Campus Networks Can Have Layer 2, Layer 3, or ATM Backbones

Building Building Building


Access Catalyst
Layer L2 Switch

Distribution Catalyst
Layer L3 Switch

Campus Ethernet or ATM


Backbone Layer 2 or Layer 3

Server Catalyst
Distribution L3 Switch

Catalyst
L2 Switch

Server Farm

Layer 2 Backbone Designs


Layer 2 backbone designs are commonly used when cost-effectiveness and high availability
are high priorities. Businesses operating large campus networks are also increasingly looking
for infrastructure upgrades to
■ Support high-bandwidth applications based on IP
■ Provide high performance and fast recovery from failures
■ Support applications based on Novell IPX, DECnet, AppleTalk, and SNA
Campus building blocks and server farms connect to the backbone with redundant Gigabit
Ethernet, Gigabit EtherChannel, 10 Gigabit Ethernet, or 10 Gigabit EtherChannel trunks.
In this design, Catalyst 3550, 4500, and 6500 switches are typically used at the distribution
layer and Catalyst 6500 switches at the core layer.

Layer 3 Backbone Designs


Layer 3 backbone designs are commonly used when very high performance is desired for
supporting multimedia applications based on IP unicast and multicast. Additional require-
ments of these designs typically include the following:
■ Nonblocking campus backbone that scales to many Gigabits per second of throughput
■ Broadcast containment
1439_CCNP_3.book Page 37 Monday, November 15, 2004 10:35 AM

Building-Block Approach 37

■ Very fast deterministic failure recovery campus-wide


■ Support for applications based on Novell IPX, DECnet, AppleTalk, and SNA
This design solution provides a manageable switched infrastructure that scales to a huge
campus with many buildings and tens of thousands of networked devices.
Buildings connect to a very high-performance, nonblocking Layer 3 switched backbone. Fast
failure recovery is achieved campus-wide using a Layer 3 routing protocol such as Enhanced
Interior Gateway Routing Protocol (EIGRP), Open Shortest Path First (OSPF), or Intermedi-
ate System-to-Intermediate System (IS-IS). One or several high-capacity server farms pro-
vide application resources to the campus.
The Layer 3 backbone is ideal for multicast traffic because Protocol-Independent Multicast
(PIM) runs on the Layer 3 switches in the backbone. PIM routes multicasts efficiently to their
destinations along a shortest-path tree, as opposed to the multicast flooding inherent in a
Layer 2 switched backbone design.
In this design, Catalyst 3550, 4500, and 6500 switches are typically used at the distribution
layer; Catalyst 6500 switches are often used at the core layer. Although Catalyst 8500 Campus
Switch Routers were often used in the core in the past, they have largely been replaced
by Catalyst 6500 switches. All these switches can intelligently distribute a load via routing
protocols.

ATM Backbone Designs


ATM backbone designs are typically used for a very large switched campus intranet that
demands high performance and availability. Requirements of these designs typically include
the following:
■ High performance and very high availability for IP applications
■ Trunking for native real-time voice and video applications
■ Fast deterministic failure recovery for high application availability
■ Support for applications based on Novell IPX, DECnet, AppleTalk, and SNA
The ATM backbone design solution provides a manageable switched infrastructure for a large
campus with thousands of networked devices.
Buildings are connected across a high-performance ATM switched backbone. IP routing pro-
tocols as well as ATM routing with Private Network-to-Network Interface (PNNI) provide
network redundancy and high availability. One or more high-capacity server farms provide
resources to the campus.
In this design, Catalyst 6500 switches and Catalyst 8500 Switch Routers are typically used at
the distribution layer; Catalyst 8540 Multiservice Switch Routers are used at the core layer.
1439_CCNP_3.book Page 38 Monday, November 15, 2004 10:35 AM

38 Chapter 1: Campus Networks and Design Models

Although ATM is still popular in the world of telecommunications, its use as a campus back-
bone solution is on the decline.

Basic Configuration of the Switch


This section introduces the basic procedures network engineers go through in administering
a switched network. These procedures include establishing passwords, password recovery,
remote access, and speed and duplex settings.

Cabling the Switch Block


Before switch configuration is begun, physical connectivity between the switch and a work-
station must be established. Two types of cable connections are used to manage the switch:
■ Through the console port—The console port is used to initially configure the
switch. The port itself normally does not require configuration.
■ Through the Ethernet port—To access the switch via the Ethernet port, the switch
must be assigned an IP address.
As Table 1-3 documents, when connecting the switch’s Ethernet ports to Ethernet-compatible
servers, routers, or workstations, use a straight-through unshielded twisted-pair (UTP) cable.
When connecting the switch to another switch, you must use a crossover cable.

Table 1-3 Straight-Through and Crossover UTP Connections Used Between Networking Devices,
Particularly at the Access Layer

Host Switch Router

Host Crossover Straight-through Crossover


Switch Straight-through Crossover Straight-through
Router Crossover Straight-through Crossover
Fiber-optic cable could also be used for these combinations of devices, provided that the devices
support fiber-optic connections.

Connecting to the Console Port


Before starting to configure a switch “out of the box,” you need to access the operating sys-
tem using a console connection from a management terminal. The management terminal is
usually a workstation with a terminal emulation program such as HyperTerminal. An RJ-45-
to-RJ-45 rollover cable is used to connect the workstation from its serial port to the console
port of the Cisco switch, as shown in Figure 1-27.
1439_CCNP_3.book Page 39 Monday, November 15, 2004 10:35 AM

Basic Configuration of the Switch 39

Figure 1-27 Console, or Rollover, Cables Are Used to Configure Catalyst Switches

Console Port (RJ-45)

RJ-45 to RJ-45
Rollover Cable

RJ-45 to DB-9 or Laptop Computer


RJ-45 to DB-25 Adapter

The steps to establish a console connection from a workstation to a switch are as follows:
Step 1 Connect one end of the supplied rollover cable to the console port.
Step 2 Attach one of the following supplied adapters to a management station or
modem:
■ RJ-45-to-DB-9 female data terminal equipment (DTE) adapter (labeled
Terminal) to connect a PC
■ RJ-45-to-DB-25 female DTE adapter (labeled Terminal) to connect a
UNIX workstation
■ RJ-45-to-DB-25 male data communications equipment (DCE) adapter
(labeled Modem) to connect a modem
Step 3 Connect the other end of the supplied rollover cable to the adapter.
Step 4 From the management station, start the terminal emulation program.
1439_CCNP_3.book Page 40 Monday, November 15, 2004 10:35 AM

40 Chapter 1: Campus Networks and Design Models

Connecting to an Ethernet Port


The Catalyst 2900XL, 2950, 3500XL, 3550, 4000, 4500, 5000, 5500, 6000, and 6500 series
switches have ports that can be configured for either 10BASE-T, 100BASE-T, or 1000BASE-T
connections. Catalyst 6500 series switches also have module options supporting 10 Gigabit
Ethernet.
When connecting the switch to servers, workstations, and routers, you must use a straight-
through cable. When connecting to other switches or repeaters, you must use a crossover
cable. The port status light emitting diode (LED) illuminates when both the switch and the
connected device are powered up. If the LED is not illuminated, it is possible that one of the
devices might not be turned on, there might be a problem with the adapter on the attached
device or with the cable, or the wrong type of cable might be in use.
After setting up the basic IP configuration, you can access the switch through Telnet unless
security policy precludes Telnet access.
Many applications, such as Tera Term, QVT Term, HyperTerminal, PUTTY (Pretty Useful
TTY), SecureCRT, and Secure Shell, include terminal emulation programs that can be used
for console access to a Cisco switch. These applications also provide other access options
such as Telnet (TCP port 23) and Secure Shell (TCP port 22).

Clearing a Configuration
Cisco routers run Cisco IOS software. The CLI embedded in Cisco IOS software should be
familiar to you by now. Some Cisco Catalyst switches such as the 2950 and 3550 series use
an IOS-like operating system that is a hybrid OS that evolved from Cisco’s acquisition of
Kalpana in 1994. This Catalyst switch OS normally is referred to as command-based or
IOS-based. The term command-based comes from the fact that hundreds of commands in
various modes are used to configure a variety of technologies.
On Cisco Catalyst IOS-based switches, the CLI supports two basic modes of operation that
are password-protected and similar to the Cisco routers:
■ User EXEC mode
■ Privileged EXEC mode
No configuration changes are permitted in user EXEC mode. Changes can be entered only in
privileged EXEC mode. Privileged EXEC mode functionally equates to router privileged
EXEC mode. In privileged mode, configuration files can be viewed, as with a router. Config-
uration changes can also be made. Also similar to a router, you enter switch privileged mode
1439_CCNP_3.book Page 41 Monday, November 15, 2004 10:35 AM

Basic Configuration of the Switch 41

using the enable command. Table 1-4 describes the main command modes, how to access
each one, the prompt for that mode, and how to exit the mode.

Table 1-4 Catalyst IOS Main Command Modes

Command Exit or Access Next


Mode Access Method Prompt Mode

User EXEC This is the first level of Switch> Enter the logout
access. command.
(For the switch) To enter privileged
Change terminal set- EXEC mode, enter the
tings, perform basic enable command.
tasks, and list system
information.
Privileged From user EXEC Switch# To exit to user EXEC
EXEC mode, enter the enable mode, enter the disable
command. command.
To enter global configu-
ration mode, enter the
configure command.

Global From privileged Switch(config)# To exit to privileged


configuration EXEC mode, enter the EXEC mode, enter the
configure command. exit or end command,
or press Ctrl-Z.
To enter interface con-
figuration mode, enter
the interface configura-
tion command.

Interface From global configura- Switch(config-if)# To exit to privileged


configuration tion mode, specify an EXEC mode, enter the
interface by entering end command, or press
the interface Ctrl-Z.
command. To exit to global config-
uration mode, enter the
exit command.
continues
1439_CCNP_3.book Page 42 Monday, November 15, 2004 10:35 AM

42 Chapter 1: Campus Networks and Design Models

Table 1-4 Catalyst IOS Main Command Modes (Continued)

Command Exit or Access Next


Mode Access Method Prompt Mode

Config-vlan In global configura- Switch(config-vlan)# To exit to global config-


tion mode, enter the uration mode, enter the
vlan vlan-id command. exit command.
To return to privileged
EXEC mode, enter the
end command, or press
Ctrl-Z.

VLAN From privileged Switch(vlan)# To exit to privileged


configuration EXEC mode, enter EXEC mode, enter the
the vlan database exit command.
command.

Line From global configura- Switch(config-line)# To exit to global config-


configuration tion mode, specify a uration mode, enter the
line by entering the exit command.
line command. To return to privileged
EXEC mode, enter the
end command, or press
Ctrl-Z.

Just as with Cisco routers, IOS-based Catalyst switches have a basic and extended configura-
tion dialog that can be used for initial switch setup. A prompt to enter the System Configuration
Dialog automatically appears at power-up when no configuration exists in the switch’s nonvola-
tile RAM (NVRAM). To exit and enter the CLI operating mode, respond “No” to the prompt
when you’re asked if you want to continue with the configuration dialog.
The switch CLI can be accessed through the console interface or through a Telnet session
after an IP address has been assigned. Similar to a router, commands in a switch are additive.
This means that adding configuration statements to an existing file doesn’t completely over-
write the existing operating or running configuration. The only way to replace the running
configuration with a configuration from NVRAM is to reboot the switch.
To clear both the running configuration and startup configuration, enter the erase startup-
config command, and then reboot the switch with the reload command or power-cycle the
switch. The configuration can be erased with any of the access methods. If the switch is
rebooted during a Telnet session, the connection can be lost because the switch interface is
shut down.
1439_CCNP_3.book Page 43 Monday, November 15, 2004 10:35 AM

Basic Configuration of the Switch 43

On the 2950 and 3550 switches, the erase startup-config command erases the configuration
that is stored in NVRAM, but this does not erase the VLAN information. To erase the VLAN
information, use the delete flash:vlan.dat command. To ensure absolutely no residual con-
figurations, it is a good idea to erase the startup configuration, VLAN database, and then
reboot the switch. See Example 1-1.

Example 1-1 Delete the startup-config File and the vlan.dat File and Reboot to Ensure That There Are No
Residual Configurations on a 2950 or 3550 Switch

3550#erase start
3550#erase startup-config
Erasing the nvram filesystem will remove all files! Continue? [confirm]
[OK]
Erase of nvram: complete
3550#dir
Directory of flash:/
2 -rwx 270 Mar 16 1993 05:58:00 system_env_vars
3 drwx 64 Mar 01 1993 00:00:48 crashinfo
13 -rwx 856 Mar 01 1993 00:01:14 vlan.dat
5 -rwx 0 Mar 16 1993 05:58:00 env_vars
6 drwx 192 Mar 16 1993 05:55:44 c3550-i5k212q3-mz.121-12c.EA1a
11 -rwx 264 Mar 16 1993 05:55:44 info
12 -rwx 264 Mar 16 1993 05:55:44 info.ver
16128000 bytes total (9961984 bytes free)
3550#delete flash:vlan.dat
Delete filename [vlan.dat]?
Delete flash:vlan.dat? [confirm]
3550#dir
Directory of flash:/
2 -rwx 270 Mar 16 1993 05:58:00 system_env_vars
3 drwx 64 Mar 01 1993 00:00:48 crashinfo
5 -rwx 0 Mar 16 1993 05:58:00 env_vars
6 drwx 192 Mar 16 1993 05:55:44 c3550-i5k212q3-mz.121-12c.EA1a
11 -rwx 264 Mar 16 1993 05:55:44 info
12 -rwx 264 Mar 16 1993 05:55:44 info.ver

continues
1439_CCNP_3.book Page 44 Monday, November 15, 2004 10:35 AM

44 Chapter 1: Campus Networks and Design Models

Example 1-1 Delete the startup-config File and the vlan.dat File and Reboot to Ensure That There Are No
Residual Configurations on a 2950 or 3550 Switch (Continued)

16128000 bytes total (9963520 bytes free)


3550#reload

System configuration has been modified. Save? [yes/no]: no


Proceed with reload? [confirm]

As addressed previously, Cisco IOS-based switches use the enable command to access privi-
leged mode, where extensive configuration parameters can be viewed. However, the switch
still cannot be configured in this mode. To configure the switch, enter global configuration
mode by using the configure command. The configure command puts the switch in global
configuration mode, where switch configuration is possible.
Configuring the switch through the console port and through Telnet lets you enter commands
in real time, but only one at a time. The Cisco IOS-based switch does not immediately store
commands in NVRAM. The command copy running-configuration startup-configuration,
similar to the Cisco IOS router command, must be used. As with a router, a series of commands
can be reversed with a reload command, provided that the running configuration was not
saved to NVRAM. Note that VLAN changes made in VLAN database mode (see Chapter 2)
cannot be reversed in this way.

Setting a Password
One of the first tasks to perform when configuring a device is to secure it against unauthorized
access. The simplest form of security is to limit access to the switches with passwords. Pass-
words restrict the level of access or completely exclude a user from logging on to a switch.
Two types of passwords can be applied to switches:
■ The login password requires authorization before you access any line, including the
console.
■ The enable password requires authentication before you set or change switch parameters.
Cisco also provides levels of authority. A privilege level of 1 gives the user normal EXEC-
mode user privileges. A privilege level of 15 is the level of access permitted by the enable
password.
To set passwords on a Cisco IOS-based switch, enter either one or both of the following com-
mands in global configuration mode:
Switch(config)#enable password password
Switch(config)#enable secret password
1439_CCNP_3.book Page 45 Monday, November 15, 2004 10:35 AM

Basic Configuration of the Switch 45

The password should at the very least consist of four alphanumeric characters. The difference
between the two commands is that the enable secret command encrypts the password,
whereas the enable password command displays the password in clear text, as shown in
Example 1-2. The service password-encryption global configuration command prevents all
configured passwords from being viewed as plain text in the show running-config output.

Example 1-2 The Enable Password and the Enable Secret Password Are Options for Securing Access to Privileged
EXEC Mode

3550#show running-config
Building configuration...

Current configuration : 1518 bytes

!
version 12.1
no service pad
service timestamps debut uptime
service timestamps log uptime
no service password-encryption
!
hostname 3550
!
enable secret 5 $1$Eqe9$ThVz.PdVU538SWkvWPVNLO
enable password cisco
!
ip subnet-zero
!
!
spanning-tree extend system-id
!
!
!
interface FastEthernet0/1
no ip adress
--More--
1439_CCNP_3.book Page 46 Monday, November 15, 2004 10:35 AM

46 Chapter 1: Campus Networks and Design Models

Naming the Switch


Every switch arrives from the factory with the same default prompt: Switch>. In a large cam-
pus network, it is crucial to establish a coherent naming structure for the switches. This is
especially true because most network administrators use Telnet to connect to many switches
across the campus.
To set the host or system name on a Cisco IOS-based switch, enter the following command in
global configuration mode:
Switch(config)#hostname name

The name parameter can have from 1 to 255 alphanumeric characters.


As soon as the hostname command is entered, the system prompt assumes the host name. To
remove the system name (to bring it back to the default configuration), enter the no host-
name command in global configuration mode.

Configuring the Switch for Remote Access


For you to perform Layer 3 operations such as Telnet, ping, or remote switch management,
the switch must have a valid IP address associated with the management VLAN. Although
LAN switches are essentially Layer 2 devices, these switches do maintain an IP stack for
administrative purposes. Assigning an IP address to the switch associates that switch with the
management VLAN, provided that the subnet portion of the switch IP address matches the
subnet number of the management VLAN.
To assign an IP address to VLAN 1 on a Cisco IOS-based switch, follow these steps:
Step 1 Enter global configuration mode on the switch.
Step 2 Go to interface VLAN 1 by issuing the following command:
Switch(config)#interface vlan 1

Step 3 Enter the switch IP address and activate the interface with the following
commands:
Switch(config-if)#ip address address mask
Switch(config-if)#no shutdown

Step 4 If you’re accessing the switch across a router, you must configure a default
gateway on the switch. You can do this in global configuration mode with the
following command:
Switch(config)#ip default-gateway address

Layer 3 switches, such as the Catalyst 3550, let you configure IP addresses on any VLAN
interface, also known as a switch virtual interface (SVI). So the “management VLAN” on
such a device is whichever one the network engineer decides to separate out for that purpose.
1439_CCNP_3.book Page 47 Monday, November 15, 2004 10:35 AM

Basic Configuration of the Switch 47

Before Cisco IOS Release 12.1, Catalyst 2950 switches had a management command in
interface VLAN mode that was used to change the management VLAN to a VLAN other than
VLAN 1. VLAN 1 is the default management VLAN. Beginning with Cisco IOS Release
12.1, the management VLAN on a Catalyst 2950 switch is simply determined by configuring
an IP address on an alternative VLAN interface, administratively shutting down the VLAN 1
interface, and entering no shutdown on the alternative VLAN interface. A 2950 switch can
have only one IP address. Without inter-VLAN routing provided by a router or Layer 3
switch, the IP address of the 2950 switch can be accessed only by nodes connected to ports
that belong to the management VLAN.
With Step 1 to Step 4 just outlined, a network engineer can Telnet to the switch. Using the
additional procedure outlined in the article “Secure Shell Version 1 Support,” at http://
www.cisco.com/univercd/cc/td/doc/product/software/ios121/121newft/121t/121t1/
sshv1.htm#1019743, the switch can be configured for Secure Shell (SSH). On the 2950, this
requires the strong cryptographic software image (Cisco IOS Release 12.1(12)c or later). On
the 3550, the strong cryptographic software image (Cisco IOS Release 12.1(11)EA1 or later)
is required.
The show interface command displays the device’s IP address and subnet mask. In Example 1-3,
the management interface resides in VLAN 1, which is the default management VLAN, and it
has a subnet mask of 255.255.255.0.

Example 1-3 Hosts on VLAN 1 Can Telnet to the Switch

2950#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
2950(config)#interface vlan 1
2950(config-if)#ip address 10.1.1.1 255.255.255.0
2950(config-if)#no shutdown
2950(config-if)#
*Apr 8 17:31:19: %LINK-3-UPDOWN: Interface VLAN1, changed state to up
*Apr 8 17:31:20: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1,
changed state to up
2950(config-if)#exit
2950(config)#ip default-gateway 10.1.1.254
2950(config)#show interface fa0/1
Vlan1 is up, line protocol is up
Hardware is CPU Interface, address is 0009.430f.a400 (bia 009.430f.a400)
Internet address is 10.1.1.1/24
MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec,
continues
1439_CCNP_3.book Page 48 Monday, November 15, 2004 10:35 AM

48 Chapter 1: Campus Networks and Design Models

Example 1-3 Hosts on VLAN 1 Can Telnet to the Switch (Continued)

reliability 255/255, txload 1/255, rxload 1/255


Encapsulation ARPA, loopback not set
ARP type: ARPA, ARP Timeout 04:00:00
Last input 5w3d, output never, output hang never
Last clearing of "show interface" counters never
Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0
Queueing strategy: fifo
Output queue :0/40 (size/max)
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 5000 bits/sec, 5 packets/sec
2258699 packets input, 203684534 bytes, 0 no buffer
Received 62611 broadcasts, 0 runts, 0 giants, 0 throttles
0 input errors, 0 CRC, 0 frame, 0 overrun, 16 ignored
11465385 packets output, 2790388760 bytes, 0 underruns
0 output errors, 6 interface requests
0 output buffer failures, 0 output buffers swapped out
--More--

To remove the IP address and subnet mask, enter the no ip address command on the VLAN
interface. You would do this, for example, if you were changing the management VLAN.

Lab 1.6.1 Catalyst 2950T and 3550 Series Basic Setup


In this lab exercise, you configure a Cisco Catalyst 2950T or 3550 series Ethernet
switch for the first time using CLI mode. You complete basic first-time tasks such
as configuring a switch name and passwords and assigning an IP address to the
Management VLAN for remote management purposes.

Identifying Individual Ports


A description added to an interface or port helps identify specific information about that
interface. For example, information could include what access or distribution layer device
the interface services. The description command is very useful in an environment where a
switch has numerous connections and the administrator needs to check a link to a specific
location. This description is meant solely as a comment to help identify how the interface is
being used or where it is connected. It could include the floor number or the office number or
name. This description appears in the configuration information output.
1439_CCNP_3.book Page 49 Monday, November 15, 2004 10:35 AM

Basic Configuration of the Switch 49

To add a unique comment to an interface on a Cisco IOS-based switch, enter the following
command in interface configuration mode:
Switch(config-if)#description description string

The string might be up to 80 characters, as shown in Example 1-4.

Example 1-4 Standard Operating Procedure Is to Include Descriptions on Switch Ports

3550(config)#interface fa0/1
3550(config-if)#description :Connection to 3rd Floor"
3550(config-if)#end
3550#
02:07:26: %SYS-5-CONFIG_I: Configured from console by console
3550#show running-config
Building configuration...

Current configuration : 1584 bytes


!
version 12.1
no service pad
service timestamps debug uptime
service timestamps log uptime
no service password-encryption
!
hostname 3550
!
enable secret 5 $1$Eqe9$ThVz.PdVU538SWkvWPVLNLO
enable password cisco
!
ip subnet-zero
!
!
spanning-tree extend system-id
!
!
!
interface FastEthernet0/1
description :Connection to 3rd Floor"
--More--
1439_CCNP_3.book Page 50 Monday, November 15, 2004 10:35 AM

50 Chapter 1: Campus Networks and Design Models

To clear a description, enter the no description command on the interface in interface


configuration mode.

Defining Port Speed and Line Mode on a Switch


Setting the port speed and line mode (duplex) are among the most common configuration
requirements for a network engineer. It can be frustrating to see messages constantly appear
on the console screen, complaining about speed or duplex mismatches. Although autonegotiation
is generally supposed to take care of speed configuration, frequently the setting must be hard-
coded. You can avoid much frustration by proactively configuring port speed rather than
depending on autonegotiation. If the port speed and duplex are hard-coded, connected
devices should be configured with the same parameters.
The order of configuration for speed and duplex is important:
1. Configure the speed for a port.

2. Follow with the duplex configuration.

Full duplex is the simultaneous action of transmitting and receiving data by two devices. This
operation can be achieved only if the devices on each end support full duplex.
NOTE
Full-duplex links not only double potential throughput, but also eliminate collisions and the
Because the behavior of
need for each station to wait until the other station finishes transmitting. If reads and writes
switch ports on Catalyst
switches with respect on a full-duplex link are symmetric, data throughput theoretically can be doubled. However,
to speed, duplex, in reality, bandwidth improvements are more modest.
default settings, and
autonegotiation is spe- Full-duplex links are particularly useful for server-to-server, server-to-switch, and switch-to-
cific to the platform and
Cisco IOS release, it is
switch connections.
not worth memorizing
The following guidelines can serve as a reference when you configure speed and duplex set-
all the rules governing
the behavior. Instead, tings on IOS-based switches:
it is recommended that
you consult Cisco.com. ■ Gigabit Ethernet ports should always be set to 1000 Mbps, but they can negotiate full
For example, see http:// duplex with the attached device. To connect to a remote Gigabit Ethernet device that
www.cisco.com/
univercd/cc/td/doc/
does not autonegotiate, disable autonegotiation on the local device, and set the duplex
product/lan/cat2950/ parameters to be compatible with the other device. Gigabit Ethernet ports that do not
12114ea1/2950cr/ match the settings of an attached device lose connectivity and do not generate statistics.
cli2.htm#1027083 for
information on the ■ To connect to a remote 100BASE-T device that does not autonegotiate, set the duplex
speed command on setting to full duplex or half duplex, and set the speed setting to autonegotiation. Auto-
2950 switches running
Cisco IOS Release negotiation for the speed setting selects the correct speed even if the attached device
12.1(14)EA1. does not autonegotiate, but the duplex setting must be explicitly set.
1439_CCNP_3.book Page 51 Monday, November 15, 2004 10:35 AM

Basic Configuration of the Switch 51

■ 10/100/1000 ports can operate at 10 or 100 Mbps when they are set to half duplex or
full duplex, but they operate in full-duplex mode only when set to 1000 Mbps.
■ Gigabit Interface Converter (GBIC) module ports operate at only 1000 Mbps.
■ 100BASE-FX ports operate at only 100 Mbps in full duplex.
On a Cisco IOS-based switch, you set the port speed using the speed {10 | 100 | 1000 | auto}
command in interface configuration mode.
To set an interface’s duplex mode on a Cisco IOS-based switch, enter the duplex {auto | full |
half} command in interface configuration mode, as shown in Example 1-5.

Example 1-5 Configure the Speed Setting First, Followed by the Duplex Setting

2950(config)#interface fa0/1
2950(config-if)#speed 100
2950(config-if)#
*Apr 8 18:40:08: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/1,
changed state to down
2950(config-if)#
*Apr 8 18:40:09: %LINK-3-UPDOWN: Interface FastEthernet0/1, changed state to up
2950(config-if)#
*Apr 8 18:40:013: %LINEPROTO-5-UPDOWN: Line protocol on Interface
FastEthernet0/1, changed state to up
2950(config-if)#duplex full
2950(config-if)#
*Apr 8 18:40:29: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/1,
changed state to down
2950(config-if)#
*Apr 8 18:40:30: %LINK-3-UPDOWN: Interface FastEthernet0/1, changed state to up
2950(config-if)#
*Apr 8 18:40:34: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/1,
changed state to up
2950(config-if)#end

To view the configuration changes, use the show interface interface-id and show running-
configuration commands, shown in Examples 1-6 and 1-7.
1439_CCNP_3.book Page 52 Monday, November 15, 2004 10:35 AM

52 Chapter 1: Campus Networks and Design Models

Example 1-6 The show interface Command Displays the Duplex and Speed Settings

2950(config)#show interface fa0/1


FastEthernet0/1 is up, line protocol is up
Hardware is Fast Ethernet, address is 0009.430f.a401 (bia 009.430f.a401)
Description: Link to ISP
MTU 1500 bytes, BW 100000 Kbit, DLY 1000 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation ARPA, loopback not set
Keepalive set (10 sec)
Full-duplex, 100Mb/s
input flow-congrol is off, output flow-control is off
ARP type: ARPA, ARP Timeout 04:00:00
Last input 00:00:19, output 00:00:00, output hang never
Last clearing of "show interface" counters never
Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0
Queueing strategy: fifo
Output queue :0/40 (size/max)
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
644584 packets input, 68487493 bytes, 0 no buffer
Received 132743 broadcasts, 0 runts, 0 giants, 0 throttles
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
0 watchdog, 122832 multicast, 0 pause input
0 input packets with dribble condition detected
3234255 packets output, 563630304 bytes, 0 underruns
--More--

Example 1-7 The show running-config Command with the interface Keyword Provides a Convenient Way to
Verify Speed and Duplex Settings

2950#show running-config interface fa0/1


Building configuration...

Current configuration : 124 bytes


!
1439_CCNP_3.book Page 53 Monday, November 15, 2004 10:35 AM

Important IOS Features 53

Example 1-7 The show running-config Command with the interface Keyword Provides a Convenient Way to
Verify Speed and Duplex Settings (Continued)

interface FastEthernet0/1
description Link to ISP
switchport access vlan 10
no ip address
duplex full
speed 100
end

Important IOS Features


This section describes further system administration techniques, including command history,
password recovery, idle timeouts, verifying connectivity, TFTP transfers, and HTTP access.

Command-Line Recall
When you enter a command on the switch, the command is held in a buffer called the history
buffer. On a Cisco IOS-based switch, the history buffer holds the last ten commands by
default, like a router does. To access these commands, use the up and down arrows on the
keyboard.
Use the show history command to see the contents of the history buffer, as shown in
Example 1-8.

Example 1-8 The show history Command Displays Previously Entered Commands

Switch#show history
enable
show running-configuration
show interface fastethernet 0/2
show vtp status
!!
show history
Switch#

To change the size of the history buffer, use the terminal history size size command, as
shown in Example 1-9.
1439_CCNP_3.book Page 54 Monday, November 15, 2004 10:35 AM

54 Chapter 1: Campus Networks and Design Models

Example 1-9 The terminal history size Command Conveniently Sets the Number of Commands Stored in the
History Buffer

Switch#terminal history size 100


Switch#

Switch#show history
enable
show running-configuration
show interface fastethernet 0/2
show vtp status
show history
terminal history size 100
show history
Switch#

Using the Help Feature


The help command on a Cisco IOS-based switch works the same as that on a router. On a
switch, you can access help by entering a question mark (?) on the command line. The switch
then prompts you with all the possible choices for the next parameter. If you enter the next
parameter followed by ?, the switch displays the next set of command-line choices. In fact,
the switch displays help on a parameter-by-parameter basis. Additionally, when the switch
displays help options, it ends by displaying the portion of the command entered so far. This
lets you append commands to the line without needing to reenter the previous portion of the
command. See Example 1-10.

Example 1-10 ? Is Used to View All Subcommands of a Given Command

Switch#?
Exec commands:
access-enable Create a temporary Access-List entry
access-template Create a temporary Access-List entry
archive manage archive files
cd Change current directory
clear Reset functions
clock Manage the system clock
cns CNS subsystem
configure Enter configuration mode
connect Open a terminal connection
copy Copy from one file to another
1439_CCNP_3.book Page 55 Monday, November 15, 2004 10:35 AM

Important IOS Features 55

Example 1-10 ? Is Used to View All Subcommands of a Given Command (Continued)

debug Debugging functions (see also 'undebug')


delete Delete a file
dir List files on a filesystem
disable Turn off privileged commands
disconnect Disconnect an existing network connection
dot1x IEEE 8021.X commands
enable Turn on privileged commands
erase Erase a filesystem
exit Exit from the EXEC
format Format a filesystem
fsck Fsck a filesystem
help Description of the interactive help system
lock Lock the terminal
login Log in as a particular user
logout Exit from the EXEC
mkdir Create a new directory
more Display the contents of a file
mrinfo Request neighbor and version information from a multicast router
mrm IP Multicast Routing Monitor Test
mstat Show statistics after multiple multicast traceroutes
mtrace Trace reverse multicast path from destination to source
name-connection Name an existing network connection
no Disable debugging functions
ping Send echo messages
pwd Display current working directory
rcommand Run command on remote switch
reload Halt and perform a cold restart
rename Rename a file
resume Resume and active network connection
rmdir Remove existing directory
rsh Execute a remote command
send Send a message to other tty lines
setup Run the SETUP command facility
--More--
1439_CCNP_3.book Page 56 Monday, November 15, 2004 10:35 AM

56 Chapter 1: Campus Networks and Design Models

Password Recovery
Each networking device has its own procedure for recovering passwords. For Cisco devices,
the procedures are conveniently organized by platform in the document “Password Recovery
Procedures” (Document ID: 6130) at http://www.cisco.com/warp/public/474/.
As with many security situations, it is extremely important to consider physical security of
the equipment. As demonstrated in the password recovery process, an attacker simply needs
to be able to reboot the Catalyst switch and access the console to enter privileged mode. When
in privileged mode, the attacker can make any changes he or she desires. Keep the wiring
closets secured, and minimize access to console ports.
The following steps for recovering passwords apply to Catalyst 2950 and 3550 switches.
They assume that a console connection is used:
Step 1 Unplug the power cable.
Step 2 Hold down the MODE button located on the left side of the front panel while
reconnecting the power cord to the switch. Release the mode button a second
or two after the LED above port 1x is no longer lit. The following instructions
appear:
The system has been interrupted prior to initializing the Flash file system. The
following commands will initiate the Flash file system, and finish loading the
operating system software:
flash_init
load_helper
boot

Step 3 Enter flash_init. This initializes the Flash file system.


Step 4 Enter load_helper. This loads and initializes the helper image, which is a
minimal IOS image stored in ROM that is typical for disaster recovery.
Step 5 Enter dir flash: (do not forget the colon). This displays a list of files and
directories in the Flash file system.
Step 6 Enter rename flash:config.text flash:config.old to rename the configuration
file. This is the file that contains the password definition.
Step 7 Enter boot to reboot the system.
Step 8 Enter n (for “no”) at the prompt to bypass the System Configuration dialog.
Step 9 At the normal switch prompt, enter enable to enter privileged mode.
Step 10 Enter rename flash:config.old flash:config.text to rename the configuration
file to its original name.
1439_CCNP_3.book Page 57 Monday, November 15, 2004 10:35 AM

Important IOS Features 57

Step 11 Copy the configuration file, config.text, into the running configuration:
Switch#copy startup-config running-config
Destination filename [running-config]? <press ENTER>
1613 bytes copied in 1.316 secs (1613 bytes/sec)
Switch#

The configuration is now reloaded.


Step 12 Change the password or passwords:
Switch#configure terminal
Switch(config)#no enable password
Switch(config)#enable secret cisco
Switch(config)#^Z

Step 13 Save the running configuration to the configuration file:


Switch#copy running-configuration startup-configuration

This procedure is more complicated than Cisco router password recovery.

Lab 1.6.3 Catalyst 2950T and 3550 Series Password Recovery


In this lab exercise, you recover passwords while retaining configurations for the
Catalyst 2950T and 3550 series Ethernet switches.

Setting an Idle Timeout


If a user is logged into a switch and performs no keystrokes or remains idle for 10 minutes,
the switch automatically logs the user out. This feature is called idle timeout. If the user
doesn’t log out and the terminal is left unattended, this feature prevents someone from gain-
ing unauthorized access to the switch by using the terminal. Although the default setting of
this feature is 10 minutes, it can be altered with the exec-timeout line console command:
Switch(config-line)#exec-timeout number of minutes number of seconds

This command works just like the router command. Example 1-11 shows the commands to
set the timeout on the console port of a Cisco IOS-based switch to 20 minutes.

Example 1-11 The exec-timeout Command Logs a User Out After the Specified Idle Timeout

Switch(config)#line console 0
Switch(config-line)#exec-timeout 20

Verifying Connectivity
After you assign the switch an IP address and connect at least one switch port to the network
and properly configure it, the switch can communicate with other nodes on the network. This
communication goes beyond simply switching traffic.
1439_CCNP_3.book Page 58 Monday, November 15, 2004 10:35 AM

58 Chapter 1: Campus Networks and Design Models

To test connectivity to remote hosts, enter the following command in privileged mode:
Switch#ping destination ip address

The ping command usually returns one of the following responses:


■ Success rate is 100 percent—This response occurs in 1 to 10 seconds, depending on
network traffic and the number of Internet Control Message Protocol (ICMP) packets
sent.
■ Destination does not respond—No answer message is returned if the host does not
respond.
■ Unknown host—This response occurs if the targeted host does not exist.
■ Destination unreachable—This response occurs if the default gateway cannot reach
the specified network.
■ Network or host unreachable—This response occurs if there is no entry in the route
table for the host or network.
Example 1-12 shows that the destination IP address 172.16.1.1 can be reached by the device
generating the ping.

Example 1-12 The ping Command Verifies Layer 3 Connectivity

Switch#ping 172.16.1.1

Type escape sequence to abort.


Sending 5, 100-byte ICMP Echos to 172.16.1.1, timeout is 2 seconds:
!!!!!
Success rate is 100 percent (5/5), round-trip min/avg/max = 1/2/4 ms
Switch#

Backup and Restoration of a Configuration Using a TFTP Server


Most switches have a Trivial File Transfer Protocol (TFTP) client, allowing configuration
files to be sent to and retrieved from a TFTP server.
For the switch to obtain the new configuration over the network, after the configuration is
cleared, you must configure a valid IP address and default gateway setting.
For complete system recovery, make sure that a copy of the configuration file of each switch
has been stored somewhere other than on the switch itself. It is a big mistake to have to
rebuild the entire configuration file from scratch during a system outage, especially when a
backup copy could have easily been created as a backup on a network-accessible machine.
1439_CCNP_3.book Page 59 Monday, November 15, 2004 10:35 AM

Important IOS Features 59

Through TFTP, a configuration file can be stored on a TFTP server and recovered later when
needed.
Transferring Cisco IOS-based switch configuration files via TFTP to another device works CAUTION
the same as with a router. The command copy startup-config tftp copies the configuration TFTP servers are inher-
ently weak in security.
file to a TFTP server at the location specified by the IP address.
TFTP uses UDP port
The recovery process works in reverse. To recover a configuration file from a TFTP server, 69. It is highly recom-
mended that you not
issue the command copy tftp running-config. This loads the specified configuration file into keep your configura-
the switch’s active memory. When the configuration file is retrieved, it can be written to Mac- tion files in a TFTP
directory space until
romedia Flash, to the startup configuration (NVRAM), or to the running configuration. you need them. Any-
one who compromises
the TFTP server can
Lab 1.6.2 Catalyst 2950T and 3550 Configuration and IOS Files
modify the configura-
In this lab exercise, you upload and download configuration files and IOS system tion files without
approval. A prudent
image files. network administrator
maintains configura-
tion files in a secure
directory space and
HTTP Access to the Switch copies them back to the
The Catalyst Web Interface (CWI), shown in Figure 1-28, is a browser-based tool that can TFTP directory space
only when he or she is
be used to configure Catalyst 4000 family switches running CatOS. Note that each Catalyst ready to use them.
platform has its own particular flavor of HTTP access. Communication between the client Although this adds
another step to the
and server usually occurs on a TCP/IP connection. The TCP/IP port number for HTTP is 80.
recovery process, the
In this client/server mode, the client (browser) opens a connection to the server (switch) and security benefits defi-
sends a request. The server receives the request, sends a response to the client, and closes the nitely outweigh the pro-
cedural disadvantages.
connection.

Figure 1-28 The Catalyst Web Interface Includes the CiscoView GUI, Which Permits HTTP
Configuration of Catalyst 4000 Family Switches Running CatOS
1439_CCNP_3.book Page 60 Monday, November 15, 2004 10:35 AM

60 Chapter 1: Campus Networks and Design Models

When you log into the switch via HTTP, a dialog box appears and prompts you for the
device’s username and password (the default authentication requires a password only). After
you provide the correct username and password, the system authenticates the login with the
HTTP user authentication method. The system denies access unless the username and pass-
word are valid. In the default configuration, verification is enabled for all users of the CWI.
The system validates the login password against the enable password.
Note that the enable password is sent over the network in clear text. Therefore, the CWI is not
a tool that should be used in a nonsecure environment.
To access the switch using HTTP, enter the switch IP address in the browser’s Location field
(Netscape) or Address field (Microsoft Internet Explorer), and then enter the switch password
when prompted.
An opening screen with various options appears. Click the Web Console option to enter the
mode that lets switch configurations be made.
Similar to CWI for 4000 family switches running CatOS, the Cisco Cluster Management
Suite (CMS) software is web-based network management software embedded in Cisco
Catalyst 2900XL, 2950, 3500XL, and 3550 switches. Also note that many Cisco vulnera-
bilities have been identified with the HTTP server functionality on Catalyst switches.

Lab 1.6.4 Introduction to Fluke Network Inspector


In this lab exercise, you learn how to use the Network Inspector (NI) from Fluke
Networks to discover and analyze network devices in a broadcast domain.

Lab 1.6.5 Introduction to Fluke Protocol Expert


In this lab exercise, you learn how to use the Fluke Networks Optiview Protocol
Expert (PE) to analyze network traffic and troubleshoot switched networks.

Summary
After completing this chapter, you should understand the following:
■ Broadcasts are useful and necessary traffic. However, too much broadcast traffic can
cause network performance problems. Managing broadcast traffic is a critical aspect of
campus LAN design.
■ The location of common workgroups and servers can have a significant impact on
traffic patterns.
1439_CCNP_3.book Page 61 Monday, November 15, 2004 10:35 AM

Summary 61

■ Adding bandwidth is not necessarily the long-term solution to meeting the needs of
high-priority traffic.
■ Multilayer switching combines Layer 2 switching and Layer 3 routing functionality
and caching of Layer 4 port information.
■ The multilayer design model is inherently scalable. Layer 3 switching performance
scales because it is distributed. Backbone performance scales as you add more links
or switches.
■ A switch block is the unit that contains distributed network services and network intel-
ligence. A switch block consists of Layer 2 switches, Layer 3 switches, and sometimes
distributed servers.
■ A core block is the unit that transfers cross-campus traffic. It can consist of Layer 2 or
Layer 3 devices.
■ The purpose of network link redundancy is to provide alternative physical pathways
through the network in case one pathway fails.
■ How to make initial connections to the switch, connecting to the console port and an
Ethernet port.
■ Basic configuration of the switch includes
— Clearing a configuration
— Setting a password
— Naming the switch
— Configuring the switch for remote access
— Identifying individual ports
— Defining link speed and line mode on a switch
■ Important IOS features include
— Command-line recall
— Using the help feature
— Password recovery
— Verifying connectivity
— Saving the configuration
— Backup and restoration of a configuration using a TFTP server
1439_CCNP_3.book Page 62 Monday, November 15, 2004 10:35 AM

62 Chapter 1: Campus Networks and Design Models

Key Terms
Application-Specific Integrated Circuit (ASIC) A chip designed for a particular applica-
tion (as opposed to the integrated circuits that control functions such as RAM).
broadcast domain The set of all devices that receive broadcast frames originating from any
device in the set. Broadcast domains are typically bounded by routers because routers do not
forward broadcast frames.
Cisco Group Management Protocol (CGMP) A Cisco-developed protocol that runs
between Cisco routers and Catalyst switches to leverage IGMP information on Cisco routers
to make Layer 2 forwarding decisions on Catalyst switch ports that are attached to interested
receivers.
collision domain In Ethernet, the network area within which frames that have collided are
propagated. Repeaters and hubs propagate collisions; LAN switches, bridges, and routers
do not.
flow A unidirectional sequence of packets between a particular source and destination that
share the same Layer 3 and Layer 4 information.
Hot Standby Router Protocol (HSRP) Provides high network availability and transparent
network topology changes. HSRP creates a hot standby router group with a lead router that
services all packets sent to the hot standby address. The lead router is monitored by other
routers in the group, and if it fails, one of these standby routers inherits the lead position and
the hot standby group address.
Internet Control Message Protocol (ICMP) A network layer Internet protocol that reports
errors and provides other information relevant to IP packet processing. Documented in
RFC 792.
Internet Group Management Protocol (IGMP) Used by IP hosts to report their multicast
group memberships to an adjacent multicast router.
nonblocking The ability to switch a packet immediately without encountering a busy
condition.
Spanning Tree Protocol (STP) A bridge protocol that uses the spanning-tree algorithm,
allowing a learning bridge to dynamically work around loops in a network topology by creat-
ing a spanning tree. Bridges exchange Bridge Protocol Data Unit (BPDU) messages with
other bridges to detect loops and then remove the loops by shutting down selected bridge
interfaces. STP refers to both the IEEE 802.1 Spanning Tree Protocol standard and the earlier
Digital Equipment Corporation Spanning Tree Protocol on which it is based. The IEEE ver-
sion supports bridge domains and allows the bridge to construct a loop-free topology across
an extended LAN. The IEEE version is generally preferred over the Digital version.
1439_CCNP_3.book Page 63 Monday, November 15, 2004 10:35 AM

Check Your Understanding 63

VLAN Trunking Protocol (VTP) A Cisco-proprietary protocol that uses Layer 2 trunk
frames to communicate VLAN information among a group of switches and to manage the
addition, deletion, and renaming of VLANs across the network from a central point of
control.

Check Your Understanding


Use the following review questions to test your understanding of the concepts covered in this
chapter. Answers are listed in Appendix A, “Check Your Understanding Answer Key.”
1. Which of the following are key requirements in a modern campus network?

A. Redundancy

B. Scalability

C. 80/20 rule

D. Multicasting
2. Which of the following is not a category of service in a campus network?

A. Local

B. Geographic

C. Remote

D. Enterprise
3. Which of the following layers typically involve Layer 3 switching?

A. Access

B. Distribution

C. Session

D. Core
4. What layer is the point at which end users are allowed into the network?

A. Access

B. Distribution

C. Session

D. Core
1439_CCNP_3.book Page 64 Monday, November 15, 2004 10:35 AM

64 Chapter 1: Campus Networks and Design Models

5. Which of the following are backbone campus network solutions?

A. Layer 2 switching

B. Layer 3 switching

C. Layer 4 switching

D. ATM
6. What type of cable is used to configure Catalyst 2950 switches through a console
connection?
A. Coaxial

B. Straight-through

C. Crossover

D. Rollover
7. What type of UTP cable can be used to connect FastEthernet ports on two Catalyst
3550 switches?
A. Coaxial

B. Straight-through

C. Crossover

D. Rollover
8. What two commands are used to restore a Catalyst 3550 switch to a default
configuration?
A. delete startup-config

B. erase startup-config

C. delete vlan.dat

D. erase vlan.dat
9. Which of the following commands are used with password recovery on a Catalyst 2950
switch?
A. flash_init

B. load_helper

C. rename

D. boot
1439_CCNP_3.book Page 65 Monday, November 15, 2004 10:35 AM

Check Your Understanding 65

10. What command is used to set the port speed to 100 on a Catalyst 3550 10/100 interface?

A. set speed

B. speed

C. bandwidth

D. set bandwidth
1439_CCNP_3.book Page 66 Monday, November 1, 2004 11:16 AM

Objectives
After completing this chapter, you will be able to perform tasks related to the following:
■ Understand and explain the role of virtual LANs (VLANs) and VLAN protocols in
modern campus networks.
■ Know the definitions and understand the various ways in which VLANs are categorized.
■ Configure VLANs.
■ Describe situations in which VLANs are appropriate.
■ Explain reasons not to use VLANs.
■ Understand VLAN Membership Policy Server (VMPS).
■ Understand and configure Dynamic Trunking Protocol (DTP).
■ Understand and configure VLAN Trunking Protocol (VTP).
1439_CCNP_3.book Page 67 Wednesday, October 27, 2004 9:54 AM

Chapter 2

VLANs and VTP


Promotion of virtual LANs (VLANs) in the 1990s by the trade journals and the workforce cre-
ated confusion. Authors used different and inconsistent interpretations of the new network termi-
nology. Vendors also took varied approaches to creating VLANs, which led to further confusion.
VLAN designs have changed over the last decade as a result of advances in technology. In the
mid-1990s, deployment of campus-wide VLANs was acknowledged as the best design method-
ology. Local or geographic VLANs are now considered the better design methodology, because
VLANs are separated by geographic location and not by function.
The speed of Layer 2 switching influenced campus-wide VLAN design. Multilayer switches can
perform Layer 3 switching at rates approximating that of Layer 2 switching. Hardware-based
Layer 3 switching provided speeds of hundreds of millions of packets per second (pps). Although
campus-wide VLANs play a role in special circumstances, designing a stable, scalable campus
network has become more important.
The CPU-intensive Spanning Tree Protocol (STP) essential to campus-wide VLANs causes con-
vergence and redundancy problems in some large networks, making them susceptible to network
instabilities. With the widespread adoption of high-performance Layer 3 switches, the campus-
wide model has become obsolete and is no longer recommended in most network designs.
With a local VLAN model, Layer 3 switching allows the users’ traffic to be carried based on the
network layer address, such as the IP address. VLANs then become a simple mechanism of seg-
menting an IP subnet at Layer 2. For example, the 172.16.10.0/24 subnet is mapped to VLAN
10, the 172.16.20.0/24 subnet is mapped to VLAN 20, and so forth. A critical tenet of campus
design declares that user VLANs terminate at a Layer 3 switch, which is typically located in a
data center or basement of a building.
1439_CCNP_3.book Page 68 Wednesday, October 27, 2004 9:54 AM

68 Chapter 2: VLANs and VTP

In this chapter, you learn how to do the following:


■ Clarify the role of VLANs and VLAN protocols in modern campus networks.
■ Present definitions and categorizations for VLANs.
■ Explain how to configure VLANs.
■ Describe situations in which VLANs are appropriate.
■ Clarify misinformation about VLANs.
■ Introduce VLAN management tools such as VLAN Trunking Protocol (VTP).

VLAN Basics
VLANs are pervasive in multilayer switched networks. This section introduces VLANs, the
motivation for their use, and how they relate to security, broadcast domains, bandwidth utili-
zation, and router latency.

Describe a VLAN
A VLAN is a logical construct that includes a group of hosts with a common set of require-
ments that communicate as if they were attached to the same wire, regardless of their physical
location. A VLAN has the same attributes as a physical LAN, but it allows end stations to be
grouped even if they are not located on the same physical LAN segment.
Networks that use the campus-wide or end-to-end VLANs logically segment a switched
network based on an organization’s functions, project teams, or applications, as shown in
Figure 2-1, rather than on a physical or geographic basis. For example, all workstations and
servers used by a particular workgroup can be connected to the same VLAN, regardless of
their physical network connections or interaction with other workgroups. Network reconfigu-
ration can be done through software instead of physically relocating devices.
Cisco recommends the use of local or geographic VLANs that segment the network based on
Internet Protocol (IP) subnets. In Figure 2-2, each wiring closet switch is on its own VLAN or
subnet, and traffic between each switch is routed by the router (except for the users in VLAN
10 on distinct access layer switches). The examples shown in Figures 2-1 and 2-2 do not
show the entire network model. The reasons for the Layer 3 switch and examples of a larger
network using both the campus-wide and local VLAN models are discussed in the later sec-
tion “VLAN Types.” VLAN member hosts are often dedicated to an access layer switch or a
cluster of access layer switches.
1439_CCNP_3.book Page 69 Wednesday, October 27, 2004 9:54 AM

VLAN Basics 69

Figure 2-1 Campus-Wide or End-to-End VLANs Can Span the Entire Campus Network and Are Not
Limited by Geography
Accounting Engineering Accounting Accounting Engineering Sales
VLAN 10 VLAN 20 VLAN 10 VLAN 10 VLAN 20 VLAN 30
172.16.10.0/24 172.16.20.0/24 172.16.10.0/24 172.16.10.0/24 172.16.20.0/24 172.16.30.0/24

Gigabit Uplinks

VLAN Trunk

Figure 2-2 Local VLANs Based on Physical Location, in One-to-One Correspondence with
IP Subnets, Are Now the Norm
Accounting Engineering Accounting Accounting Engineering Sales
VLAN 10 VLAN 20 VLAN 10 VLAN 30 VLAN 40 VLAN 50
172.16.10.0/24 172.16.20.0/24 172.16.10.0/24 172.16.30.0/24 172.16.40.0/24 172.16.50.0/24

Gigabit Uplinks

172.16.100.0/24

A VLAN can be thought of as a broadcast domain that exists within a defined set of switches.
Ports on a switch can be grouped into VLANs to limit unicast, multicast, and broadcast traffic
flooding. Flooded traffic originating from a particular VLAN is flooded only out ports belonging
to that VLAN, including trunk ports (assuming that the trunk ports are configured to carry
that VLAN traffic).
Any switch port can belong to a VLAN. Unicast, broadcast, and multicast packets are forwarded
and flooded only to stations in the same VLAN. Each VLAN is a logical network, and packets
destined for stations that do not belong to the same VLAN must be forwarded through a router
or routing device. Each VLAN can also run a separate instance of STP. The technology that
allows Cisco switches to support an independent implementation of STP for each VLAN is
called Per-VLAN Spanning Tree (PVST).
1439_CCNP_3.book Page 70 Wednesday, October 27, 2004 9:54 AM

70 Chapter 2: VLANs and VTP

VLANs are created to provide flexibility and the segmentation services traditionally provided
by routers in LAN configurations. VLANs address scalability, security, and network manage-
ment issues. Routers in VLAN topologies provide broadcast filtering, security, address sum-
marization, and traffic flow management. By definition, switches cannot bridge IP traffic
between VLANs because doing so would violate the integrity of the VLAN broadcast domain
(although you can force the issue using Integrated Routing and Bridging). Normally, IP traffic
is routed between VLANs.
VLANs are essentially Layer 2 constructs, and IP subnets are Layer 3 constructs. In a campus
LAN employing VLANs, a one-to-one relationship often exists between VLANs and IP sub-
nets. It is possible to have multiple subnets on one VLAN, and in some cases one subnet
might be spread across multiple VLANs. Such cases are the exception, however, not the rule.
VLANs and IP subnets provide an example of independent Layer 2 and Layer 3 constructs
that normally map to one another. This correspondence is useful during the network design
process. Network designers must consider several key issues when designing and building
scalable multilayer switched internetworks. These issues are examined in the section
“VLAN Types.”

Motivation for VLANs


In a legacy network, administrators assign users to networks based on geography. The admin-
istrator attaches the user’s workstation to the nearest network cable. If the user belongs to the
engineering department and sits next to someone from the accounting department, they both
belong to the same network because they attach to the same segment. Topologies such as this
create interesting network issues and highlight some of the reasons for using VLANs. For
example, the engineering group might require access to simulation and modeling programs
that consume a lot of bandwidth, preventing the accountants from accessing relatively small
spreadsheet documents. VLANs help resolve many of the problems associated with legacy
network designs.
With VLANs, network managers can logically group networks that span all major topologies.
This includes high-speed technologies such as
■ ATM
■ Fast Ethernet
■ Gigabit Ethernet
■ 10 Gigabit Ethernet
By creating VLANs, system and network administrators can control traffic patterns, react
quickly to relocations, and keep up with constant changes in the network caused by moving
requirements and node relocation. VLANs provide the flexibility to carry out these actions.
The network administrator simply changes the VLAN member list in the switch configuration.
1439_CCNP_3.book Page 71 Wednesday, October 27, 2004 9:54 AM

VLAN Basics 71

The administrator can add, remove, or move devices or make other changes to the network
configuration using software. In addition to simplified administration, VLANs are also imple-
mented for their increased security and their capability to contain broadcasts.

VLANs and Network Security


Almost everything in networking has a connection to security. With VLAN technology, security
is essentially a side effect. With the exception of the private VLANs that are available on
Catalyst 4000 and 6000 family switches, security was not originally a motivating factor for
the creation of VLANs.
The shared-media nature of legacy networks is a security issue. Whenever a station transmits
in a shared network, such as a legacy half-duplex 10BASE-T system, all stations attached to
the segment receive a copy of the frame, even if they are not the intended recipients. This
does not prevent the network from functioning, but readily available software packages that
monitor network traffic make it possible for anyone to capture passwords, sensitive e-mail,
and any other unencrypted traffic on the network.
If the users on the network belong to the same department, this might not be disastrous, but
when users from mixed departments share a segment, sensitive information can be compro-
mised. For example, if someone from human resources or accounting sends sensitive data
such as salaries, stock options, or health records on the shared network, anyone with a net-
work-monitoring tool on that LAN can intercept the information.
In fact, these problems are not constrained to a single LAN segment. They can occur in
multisegment environments interconnected with routers. If the accounting department resides
on two isolated segments, packets from one segment must cross the engineering network to
reach the other accounting segment, as shown in Figure 2-3. When they cross the engineering
segment, it is possible for that information to be intercepted and misused if someone has
physical access to the switch on the engineering segment.

Figure 2-3 Traffic Can Be Intercepted When Hosts Reside on Intermediary Segments

Accounting Accounting

Engineering
1439_CCNP_3.book Page 72 Wednesday, October 27, 2004 9:54 AM

72 Chapter 2: VLANs and VTP

One way to eliminate the problem is to move all accounting users onto the same segment, but
that might not be possible. Space limitations might prevent all accountants from sharing a
common part of the building. Another reason might be the company’s geographic makeup.
Users on one segment might be a considerable distance from users on the other segment.
In most cases, assuming physical security of a switch and password-protected remote access,
the issue of intercepting data because of shared-media technology should not be a problem.
Virtually all hosts in modern networks reside on switched ports, so unicast data normally is
not visible to any hosts except the sender and receiver. However, some applications can redi-
rect data in a switched network to a single host. Without physical access to the switches,
it should not be possible to intercept data in a switched environment, but a comprehensive
security policy should take this possibility into account, especially if the LAN carries sensi-
tive data.
Another approach to securing intersubnet traffic (as shown in Figure 2-3) is through the use
of VLANs. VLANs add an additional layer of isolation between hosts and, therefore, make it
much more difficult for data to be intercepted. All process-related users can be contained
in the same broadcast domain and isolated from users in other broadcast domains. All the
accounting users can be assigned to the same VLAN, regardless of their physical location in
the facility. In fact, all the users can be assigned to VLANs based on their job function. For
example, all the accounting users could go on one VLAN, the marketing users on another
VLAN, and engineering on a third.
When VLANs are implemented with switched network devices, another level of protection is
added to the network. Switches bridge traffic within a VLAN. When a station transmits, the
frame goes to the intended destination. As long as it is a known unicast frame, the switch does
not distribute the frame to all users in the VLAN.
Station A transmits a frame to Station B, attached to another switch, as shown in Figure 2-4.
Although the frame crosses through a switch, only the destination receives a copy of the
frame. The switch does not send the frame to the other stations, whether they belong to a dif-
ferent VLAN or the same VLAN. Assuming that physical access to the switches is not possible,
this switch feature limits the opportunity for packets to be captured with a network analyzer.
Hosts on different VLANs cannot communicate with each other unless the network is explicitly
configured to allow it. If the network has a one-to-one mapping between IP subnets and
VLANs, hosts on different VLANs must communicate through IP routing. In this case, access
control lists (ACLs) can filter traffic between VLANs. It is possible to configure VLANs
without inter-VLAN routing among user VLANs, but this is rarely done.
1439_CCNP_3.book Page 73 Wednesday, October 27, 2004 9:54 AM

VLAN Basics 73

Figure 2-4 Normally, Unicast Traffic Cannot Be Intercepted by a Host Connected to the Same
Switch as Unicast Traffic Traversing the Same Switch

A B

Another case where VLANs play a definitive role in network security is the capability to con-
figure ACLs on switches. This is discussed in the section “Understanding Switch ACLs” and
in Chapter 9, “Monitoring and Security.”
Although these security methods might seem excessive, in the corporate network they are
crucial. Consider the data transferred within a company’s accounting department. This
department has salary information, stock option information, personal information, and
other sensitive and personal material. It is very important to protect the users’ privacy and the
data’s integrity. VLANs greatly assist in this endeavor.

VLANs and Broadcast Distribution


Practically every network protocol creates broadcast traffic. AppleTalk hosts, Microsoft
hosts, and Novell servers create broadcasts to announce or request services. Furthermore,
multimedia applications create broadcast and multicast frames that are distributed across the
broadcast domain.
Broadcasts are necessary to support protocol operations and, therefore, are acceptable over-
head in the network. So why do network administrators dislike broadcast traffic? Broadcasts
go to all devices in the broadcast domain and must be processed by the receiving devices.
With the exception of multimedia-based traffic, broadcast frames rarely transport user data.
Because switches flood broadcasts, they consume bandwidth in the LAN, resulting in a
reduction of the bandwidth for productive traffic.
Broadcasts also have a profound effect on the performance of workstations. Any broadcast
received by a workstation interrupts the CPU and prevents it from working on user applica-
tions. As the number of broadcasts per second increases at the interface, effective CPU utili-
zation diminishes. The actual level of degradation depends on the applications running in
the workstation, the type of network interface card and drivers, the operating system, and the
workstation platform.
1439_CCNP_3.book Page 74 Wednesday, October 27, 2004 9:54 AM

74 Chapter 2: VLANs and VTP

VLANs form broadcast domains. Broadcasts and multicasts are not propagated between VLANs
unless the intermediary network devices are specifically configured to do so (see Figure 2-5).
If broadcasts and multicasts are creating problems in the network, creating smaller broadcast
domains can mitigate the negative effects. This means creating additional VLANs and attach-
ing fewer devices to each one. The effectiveness of this action depends on the source of the
broadcast. If a local server is sending broadcast traffic, that server should be isolated in
another broadcast domain. If the broadcasts and multicasts come from end stations, creating
additional VLANs helps reduce the number of broadcasts in each domain.

Figure 2-5 Broadcasts Originating in a VLAN Do Not Propagate Beyond That VLAN’s Boundary

Broadcast Domain 2
VLAN 20 172.16.20.0/24

Broadcast Domain 1
VLAN 10 172.16.10.0/24

VLANs and Bandwidth Utilization


When users attach to the same shared segment, they all share the segment’s bandwidth. With
every additional user on the shared medium, less bandwidth is available for each user. User
network and application performance begin to diminish if the bandwidth sharing becomes too
great. The network administrator needs to take action because the users will be less produc-
tive. VLANs can offer more bandwidth to users than is inherent in a shared network; VLANs
do this by limiting the size of each broadcast domain.
Remember that each interface on a switch behaves like a port on a legacy bridge. Bridges fil-
ter traffic for the source segment. If a frame needs to cross the bridge, the bridge forwards the
frame to the correct interface. If the bridge or switch does not know the destination port, it
floods the frame to all ports in the broadcast domain (VLAN) except the source port. By
assigning ports on a switch to different VLANs, you can limit the number of switch ports to
which data traffic is flooded.
1439_CCNP_3.book Page 75 Wednesday, October 27, 2004 9:54 AM

VLAN Basics 75

In a switched environment, a station usually sees only traffic destined specifically for it. The
switch filters most of the other background traffic in the network, which allows the workstation
to have full, dedicated bandwidth for sending or receiving traffic. Unlike a shared-hub system,
in which only one station can transmit at a time, a switched network allows many concurrent
transmissions within a broadcast domain without directly affecting other stations inside or
outside the broadcast domain. In Figure 2-6, station pairs A/B, C/D, and E/F can all
communicate without affecting the other station pairs.

Figure 2-6 Internal Switched Virtual Circuits Permit Simultaneous Transmissions Between Pairs
of Hosts

E F

A C

B D

VLANs Versus Router Latency


In a traditional routed network, packets going between networks have to be routed by a
router. Every router that handles the data increases the end-to-end latency. Latency consti-
tutes the amount of time necessary to transport a frame from the source port to the destination
port. The latency could be reduced by replacing the routers with Layer 2 switches, but the
network would then become a single broadcast domain and lose other advantages of Layer 3
segmentation such as security management and traffic filtering. VLANs have the advantages
of the decreased latency of Layer 2 switching and the segmentation of Layer 3 routing.
Campus-wide VLANs were once the answer to Layer 3 latency, but they introduced their own
complexities into the network. Campus-wide VLANs are still appropriate in some circum-
stances; however, Cisco recommends designing networks using the local VLAN model. The
local VLAN model has VLANs dedicated to each access layer switch cluster, with Layer 3
switching between wiring closets performed at the distribution layer or Main Distribution
Facility (MDF). As illustrated in Figure 2-7, inter-VLAN routing is provided by Layer 3
switches, which are connected by IP subnets instead of the traditional VLAN trunks. With
both the local VLAN and campus-wide VLAN model, VLANs have many advantages over
traditional switched networks, including segmentation of broadcast domains.
1439_CCNP_3.book Page 76 Wednesday, October 27, 2004 9:54 AM

76 Chapter 2: VLANs and VTP

Figure 2-7 VLANs in Modern Campus Networks Are Local to Access Layer Switches
Accounting Engineering Accounting Accounting Engineering Sales
172.16.10.0/24 172.16.20.0/24 172.16.30.0/24 172.16.40.0/24 172.16.50.0/24 172.16.60.0/24

172.16.100.0/24

In modern campus operations, Layer 3 latency issues become rare as a result of multilayer
switching (MLS). MLS enables hardware-based routing. In Cisco switches that support
MLS, the router routes the first packet in software, and the switch handles subsequent packets
in hardware. Newer Cisco switches, such as the Catalyst 3550 and 6500, use Cisco Express
Forwarding (CEF). CEF uses a method of communicating information between the routing
table and CEF tables that allows packets to be forwarded by the switches without routing
table lookups. Chapter 5, “Multilayer Switching,” discusses MLS and CEF in more detail.

Wrong Motives for Implementing VLANs


The advent of VLANs led many to believe that a network administrator’s life would be sim-
plified, which was to be a welcome relief. Many network administrators believed that VLANs
would eliminate, to some extent, the need for routers. They also believed that because campus-
wide VLANs place all users in one large flat network, many long hours of network administration
would be eliminated. This turned out to be far from the truth and, unfortunately, enthusiasm
quickly met reality. VLANs do not eliminate Layer 3 issues. They might ease some Layer 3
tasks, such as enabling the use of simpler access lists, but routing is still a necessity. Last,
contrary to expectations, network monitoring is more challenging with a VLAN-based net-
work than with a traditional routed network, because VLANs permit much more complex
logical designs.

VLAN Security
Network security is becoming more pervasive in network design. VLAN implementation
must be factored into the network security policy. This section explores the relationship
between VLANs and network security.
1439_CCNP_3.book Page 77 Wednesday, October 27, 2004 9:54 AM

VLAN Security 77

Overview
Routers allow administrators to introduce policies that control the flow of traffic in the net-
work. ACLs control traffic flow and provide varied degrees of policy granularity. ACLs can
prevent a specific user from communicating with another user or network, or they can prevent
an entire network from accessing a user or network. ACLs are sometimes implemented for
security reasons, and they are also used to prevent traffic from flowing through a segment to
protect local bandwidth.
In any case, the management of ACLs can be quite cumbersome. ACLs in a production net-
work should be based on the organization’s business and security needs.
To safeguard the accounting department’s data, filters in the routers attached to the engineer-
ing segment can include ACLs, allowing the accounting traffic to pass through the engineering
segment, but never talk to any engineering devices (see Figure 2-8). That does not prevent
engineers from monitoring the traffic (using Catalyst Switched Port Analyzer [SPAN] tech-
nology, for example), but it does prevent explicit communication between the engineering
and accounting devices. Accounting does not see the engineering traffic, but engineering can
see all the accounting transit traffic using Catalyst SPAN technology, introduced in Chapter 9.

Figure 2-8 ACLs Can Prevent Accounting Data from Being Transferred to the Engineering
Department

Accounting Accounting

Engineering

Switches traditionally operate at Layer 2 only, switching traffic within a VLAN, whereas
routers route traffic between VLANs. The Catalyst 3550 switch with the Enhanced Multilayer
Image (EMI) installed and the Catalyst 6500 switches with the Supervisor Engine 720 can
1439_CCNP_3.book Page 78 Wednesday, October 27, 2004 9:54 AM

78 Chapter 2: VLANs and VTP

accelerate packet routing between VLANs by using Layer 3 switching. The process of rout-
ing traffic between VLANs is as follows:
1. The switch bridges the packet.

2. The packet is routed internally without going to an external router.

3. The packet is bridged again to send it to its destination.

During this process, the switch can enforce ACLs on all packets it switches, including packets
bridged within a VLAN.
Layer 3 switching uses the traditional combination of external router and Layer 2 switch, also
known as “router-on-a-stick,” into a single device. ACLs can be configured on a Layer 3
switch to provide basic security and traffic management for the network.

Understanding Switch ACLs


Packet filtering can help limit network traffic and restrict network use by certain users or
devices. ACLs can filter traffic as it passes through a router and permit or deny packets from
crossing specified interfaces. An ACL contains an ordered list of access control entries (ACEs),
also called access control entities. Each ACE specifies permit or deny and a set of conditions
the packet must satisfy to match the ACE. The meaning of permit or deny depends on the
context in which the ACL is used.
ACLs on switches function very much like those on a router. When a frame is received on an
interface, the switch compares the fields in the frame against any applied ACLs to verify that
it should be forwarded, based on the criteria specified in the ACLs. It tests frames against the
conditions in an ACL one by one.
The first match determines whether the switch accepts or rejects the packets. Because the
switch stops testing conditions after the first match, the order of conditions in the list is criti-
cal. If no conditions match, the switch rejects the packets.
If a switch is not configured with ACLs, all packets passing it are allowed onto all parts of the
network. ACLs can be used to control which hosts can access different parts of a network or
to decide which types of traffic are forwarded or blocked at router interfaces. For example, a
Layer 3 switch can be configured to allow e-mail traffic to be forwarded but not Telnet traffic.
ACLs can be configured to block inbound traffic, outbound traffic, or both.
The Catalyst 3550 and 6500 switches support two types of ACLs:
■ IP ACLs filter IP traffic, including Transmission Control Protocol (TCP), User Data-
gram Protocol (UDP), Internet Group Management Protocol (IGMP), and Internet
Control Message Protocol (ICMP).
■ Ethernet ACLs filter non-IP traffic.
1439_CCNP_3.book Page 79 Wednesday, October 27, 2004 9:54 AM

VLAN Security 79

Catalyst 6500 switches also support Internetwork Packet Exchange (IPX) ACLs. The 2950
switch with the enhanced image supports only IP ACLs.
Catalyst 3550 and 6500 switches support two applications of ACLs to filter traffic:
■ Router ACLs
■ VLAN ACLs
Catalyst 3550 and 6500 switches also support quality of service (QoS) ACLs, which are used
to implement QoS features.
Router ACLs filter routed traffic between VLANs. For a Catalyst 3550 to filter packets routed
between VLANs, it must be running EMI.
VLAN ACLs, also called VLAN maps, filter both bridged and routed packets. VLAN maps
can be used to filter packets exchanged between devices in the same VLAN. Unlike router
ACLs, a switch does not need to run EMI software to use VLAN maps. VLAN maps are con-
figured to provide access control based on Layer 3 IP addresses. Frames for non-IP protocols
can be filtered based on their Media Access Control (MAC) addresses, using Ethernet ACEs.
An ACE is a single line in an ACL.
When a VLAN map is applied to a VLAN, all packets (routed or bridged) entering the VLAN
are checked against the VLAN map. Packets can enter the VLAN either through a switch port
or through a routed port.

Router ACLs and VLAN Maps


Router ACLs are applied to switch virtual interfaces (SVIs), which are Layer 3 VLAN inter-
faces. Router ACLs are also applied to physical Layer 3 interfaces and to Layer 3 EtherChan-
nel interfaces. Router ACLs are applied on interfaces as either inbound or outbound.
One ACL can be used with multiple features for a given interface, and one feature can use
multiple ACLs. When a single router ACL is used by multiple features, such as for QoS and
security, it is examined multiple times.
Standard IP access lists use source addresses for matching operations. Extended IP access
lists use source and destination addresses and optional protocol type information for match-
ing operations.
The switch examines ACLs associated with features configured on a given interface with
a specific direction. As packets enter the switch on an interface, ACLs associated with all
inbound features configured on that interface are examined. After packets are routed and
before they are forwarded out to the next hop, all ACLs associated with outbound features
configured on the egress interface are examined.
1439_CCNP_3.book Page 80 Wednesday, October 27, 2004 9:54 AM

80 Chapter 2: VLANs and VTP

ACLs permit or deny packet forwarding based on how the packet matches the entries in
the ACL. For example, ACLs can be used to allow one host to access part of a network but
prevent another host from accessing the same part. In Figure 2-9, ACLs applied at the router
input allow Host A to access the Human Resources network but prevent Host B from access-
ing the same network.

Figure 2-9 Router ACLs Are Applied to Switch Virtual Interfaces and Routed Ports

Host A

Catalyst 3550 Switch


with Enhanced
Multilayer Software
Image
Host B
Human Research &
Resources Development
Network Network

= ACL Denying Traffic from Host B and = Packet


Permitting Traffic from Host A

VLAN maps can filter all traffic received by the switch. VLAN maps are applied to all pack-
ets that are routed into or out of a VLAN or are bridged within a VLAN. VLAN maps are
used strictly for security packet filtering. Unlike router ACLs, VLAN maps are not defined by
direction (inbound or outbound).
VLAN maps can be configured to match Layer 3 addresses for IP traffic. All non-IP protocols
are filtered through MAC addresses and Ethertype using MAC VLAN maps. IP traffic is not
access-controlled by MAC VLAN maps. VLAN maps can be enforced only on packets going
through the switch. They cannot be enforced on traffic between hosts on a hub or on another
switch connected to the switch on which the VLAN map is applied.
With VLAN maps, packets are forwarded or dropped based on the action specified in the
map. In Figure 2-10, a VLAN map is applied to deny a specific type of traffic from Host A
in VLAN 10 from being forwarded.
1439_CCNP_3.book Page 81 Wednesday, October 27, 2004 9:54 AM

VLAN Security 81

Figure 2-10 VLAN Maps or VLAN ACLs (VACLs) Can Perform Intra-VLAN Filtering

Host A Catalyst 3550 Switch Host B


(VLAN 10) Bridging Traffic (VLAN 10)

= ACL Denying Traffic from Host A in


VLAN 10 from Being Forwarded
= Packet

Configuring Router ACLs


Router ACLs are configured on Layer 3 SVIs with the same commands used to configure NOTE
ACLs on Cisco routers. The process is briefly described here. For more detailed infor-
mation on configuring
Catalyst 3550 switches do not support all IOS router ACL-related features. They do not sup- router ACLs, refer to
port the following: the Cisco IOS Security
Configuration Guide,
■ Non-IP protocol ACLs Release 12.3 at http//
www.cisco.com. For
■ Bridge-group ACLs detailed information
about the commands,
■ IP accounting
refer to the Cisco IOS
■ Rate limiting (except with QoS ACLs) Security Command
Reference, 12.3.
■ IP packets with a header length of less than 5
■ Reflexive ACLs
■ Dynamic ACLs (except for certain specialized dynamic ACLs used by the clustering
feature on the switch)
Standard and extended IP router ACLs are created on the switch just as they are on a router.
In addition to numbered standard and extended ACLs, standard and extended named and
time-range ACLs are available.
Here are the basic two steps involved in using ACLs:
Step 1 Create an ACL by specifying an access list number or name and access
conditions.
Step 2 Apply the ACL to an interface, terminal line, or VLAN map.
Existing ACLs can be displayed by using show commands.
The show access-lists command displays information about all IP and MAC ACLs or about a
specific ACL.
1439_CCNP_3.book Page 82 Wednesday, October 27, 2004 9:54 AM

82 Chapter 2: VLANs and VTP

The show ip access-lists command displays information about all IP ACLs or about a
specific IP ACL.
The show ip interface command can be used to view the input and output access groups on
the interface, as well as other interface characteristics. If IP is not enabled on the interface,
the access groups are not shown.
A Catalyst 3550 switch has a routed port, interface GigabitEthernet 0/2, connected to Server A,
as shown in Figure 2-11. Server A has benefits information and other documentation on it that
all employees can access. The switch also has routed port 0/3 connected to Server B, which
contains confidential payroll data. All users can access Server A, but Server B has restricted
access.

Figure 2-11 ACLs on Switches Can Restrict Access Between Subnets Just as They Would
on a Router

Benefits Payroll
Server A Server B

172.20.128.97/27 172.20.128.98/27

Port 0/2 Port 0/3

Catalyst 3550 Switch with Enhanced


Multilayer Switch Image

Human Resources Accounting


172.20.128.0-31/27 172.20.128.64-95/27

Use router ACLs to do this in one of two ways:


■ Create a standard ACL and filter traffic coming to the server from port 0/3.
■ Create an extended ACL and filter traffic coming from the server into port 0/3.
Example 2-1 uses a standard ACL to filter traffic coming into Server B from port 0/3, permit-
ting traffic only from hosts in the Accounting department, which have source addresses
172.20.128.64 to 172.20.128.95.
1439_CCNP_3.book Page 83 Wednesday, October 27, 2004 9:54 AM

VLAN Security 83

Example 2-1 A Standard ACL Filters Traffic to Server B

Switch(config)#access-list 6 permit 172.20.128.64 0.0.0.31


Switch(config)#end
Switch#show access-list
Standard IP access list 6 permit 172.20.128.64, wildcard bits 0.0.0.31
Switch#configure terminal
Switch(config)#interface gigabitethernet0/3
Switch(config-if)#ip access-group 6 out

The ACL is applied to traffic coming out of routed port 0/3. Only traffic from the specified
source address is permitted.
Example 2-2 uses an extended ACL to filter traffic coming from Server B into port 0/3, per- NOTE
mitting traffic from any source address (in this case, Server B) to only the Accounting desti- Refer to the Catalyst
2950 Desktop Switch
nation addresses 172.20.128.64 to 172.20.128.95.
Software Configuration
Guide, Catalyst 3550
Example 2-2 An Extended ACL Filters Traffic to Server B Multilayer Switch Soft-
ware Configuration
Switch(config)#access-list 106 permit ip any 172.20.128.64 0.0.0.31 Guide, and Catalyst
Switch(config)#end 6500 Series Software
Configuration Guide
Switch#show access-list for additional informa-
Extended IP access list 106 permit ip any 172.20.128.64 0.0.0.31 tion about configuring
ACLs and examples.
Switch#configure terminal
Switch(config)#interface gigabitethernet0/3
Switch(config-if)#ip access-group 106 in

The ACL is then applied to traffic going into routed port 0/3, permitting it to go only to the
specified destination addresses. Remember that with extended ACLs, a protocol must be
entered before the source and destination information.

Configuring VLAN Maps


This section briefly describes how to configure VLAN maps, which is the only way to control
filtering within a VLAN. VLAN maps have no direction. To filter traffic in a specific direction
using a VLAN map, you must configure an ACL with a specific source or destination address.
Unlike router ACLs, the default action for VLAN maps is to forward. This action is taken if
the packet does not match any of the entries within the map.
Each VLAN map consists of an ordered series of entries. A packet that comes into the switch
is tested against the first entry in the VLAN map. If the packet matches the first VLAN map
1439_CCNP_3.book Page 84 Wednesday, October 27, 2004 9:54 AM

84 Chapter 2: VLANs and VTP

entry, the action specified for that part of the VLAN map is taken. If no action is specified, the
default action is to forward. If no match occurs, the packet is tested against the next entry in
the map. If no entries match, the implicit forward default applies. Beginning in privileged
EXEC mode, follow the steps listed in Table 2-1 to create, add to, or delete a VLAN map
entry.
To create a VLAN map and apply it to one or more VLANs, follow these steps:
Step 1 Create the standard or extended IP ACLs or named MAC extended ACLs that
will be applied to the VLAN.
Step 2 Enter the vlan access-map global configuration command to create a VLAN
ACL map entry.
Step 3 In access map configuration mode, optionally enter an action, either drop or
forward, and enter the match command to match the packet against one or
more access lists.
Step 4 Use the vlan filter global configuration command to apply a VLAN map to
one or more VLANs.
Remember that VLAN maps have an implicit forward feature at the end of the list; a packet is
forwarded if it does not match any ACL within the VLAN map.
Follow these guidelines when configuring VLAN maps:
■ If no router ACL is configured to deny traffic on a routed VLAN interface, and no
VLAN map is configured, all traffic is permitted.
■ As with ACLs, the order of entries in a VLAN map is important.
■ The system might take longer to boot if a large number of ACLs have been configured.
Use the no vlan access-map name command to delete a map.
Use the no vlan access-map name number command to delete a single sequence entry from
within the map.
Use the no action command to enforce the default action, which is to forward.
VLAN maps do not use the specific permit or deny keywords. To deny a packet by using
VLAN maps, create an ACL that would match the packet, and set the action to drop. A
permit in the ACL counts as a match. A deny in the ACL means no match.
Example 2-3 shows how to create an ACL and a VLAN map to deny a packet. In this exam-
ple, any packets that match the ip1 ACL (TCP packets) are dropped. First, create the IP ACL
to permit any TCP packet and no other packets; then set the action for packets that match the
permit list to be dropped.
1439_CCNP_3.book Page 85 Wednesday, October 27, 2004 9:54 AM

VLAN Security 85

Table 2-1 The VLAN Map Syntax Involves Configuring a List of Action and Match Entries for Data

Step Command Description

1 configure terminal Enters global configuration mode.

2 vlan access-map name [number] Changes to access map configuration


mode. It creates a VLAN map and gives it
a name and (optionally) a number. The
number is the sequence number of the
entry within the map. When creating
VLAN maps with the same name, num-
bers are created sequentially in increments
of 10. When modifying or deleting maps,
enter the number of the map entry to be
modified or deleted.

3 action [drop | forward] (Optional) Sets the action for the map
entry. The default is to forward.

4 match {ip address | mac address} Matches the packet (using either the IP or
{name | number} [name | number] MAC address) against one or more stan-
dard or extended ACLs. Note that packets
are matched only against ACLs of the cor-
rect protocol type. IP packets are matched
against standard or extended IP ACLs.
Non-IP packets are matched only against
named MAC extended ACLs.

5 end Returns to global configuration mode.

6 show running-config Displays the ACL configuration.

7 copy running-config startup-config (Optional) Saves the configuration file.

Example 2-3 Named ACLs Are Convenient for Use in VLAN Maps to Specify Traffic to Drop or Forward. In This
Case, All TCP Traffic Is Dropped.

Switch(config)#ip access-list extended ip1


Switch(config-ext-nacl)#permit tcp any any
Switch(config-ext-nacl)#exit
Switch(config)#vlan access-map map_1 10
Switch(config-access-map)#match ip address ip1
Switch(config-access-map)#action drop
1439_CCNP_3.book Page 86 Wednesday, October 27, 2004 9:54 AM

86 Chapter 2: VLANs and VTP

Example 2-4 shows how to create a VLAN map to permit a packet. In this example, ip2
permits UDP packets, and any packets that match the ip2 ACL are forwarded.

Example 2-4 Traffic That Does Not Match an Entry in a VLAN Map Is Forwarded. Continuing from Example 2-3,
the Following Results in All Non-TCP Traffic Being Forwarded.

Switch(config)#ip access-list extended ip2


Switch(config-ext-nacl)#permit udp any any
Switch(config-ext-nacl)#exit
Switch(config)#vlan access-map map_1 20
Switch(config-access-map)#match ip address ip2
Switch(config-access-map)#action forward

In Example 2-5, any packets that do not match any of the previous ACLs (that is, packets that
are not TCP packets or UDP packets) are dropped.

Example 2-5 Continuing from Examples 2-3 and 2-4, the Following Results in All Traffic Being Dropped Except
UDP Traffic

Switch(config)#vlan access-map map_1 30


Switch(config-access-map)#action drop

Beginning in privileged EXEC mode, follow the steps listed in Table 2-2 to apply a VLAN
map to one or more VLANs.

Table 2-2 VLAN Maps Are Applied to VLANs in Global Configuration Mode

Step Command Description

1 configure terminal Enters global configuration mode.


2 vlan filter mapname vlan-list list Applies the VLAN map to one or more
VLAN IDs. The list can be a single VLAN
ID (22), a consecutive list (10-22), or a
string of VLAN IDs (12, 22, 30). Spaces
around the comma and hyphen are
optional.

3 show running-config Displays the ACL configuration.

4 copy running-config startup-config (Optional) Saves the configuration file.


1439_CCNP_3.book Page 87 Wednesday, October 27, 2004 9:54 AM

VLAN Security 87

Example 2-6 shows how to apply VLAN map 1 to VLANs 20 to 22.

Example 2-6 Applying a VLAN Map Requires Only One Command

Switch(config)#vlan filter map 1 vlan-list 20-22

To display information about VLAN access maps or VLAN filters, use the appropriate show
command from privileged EXEC mode.
The show vlan access-map [mapname] command displays information about all VLAN
access maps or a specified access map.
The show vlan filter [access-map name | vlan vlan-id] command displays information about
all VLAN filters or about a specified VLAN access map or VLAN.
Example 2-7 illustrates some show commands for ACLs and VLAN maps.

Example 2-7 Several show Commands Are Available for Verifying ACLs and VLAN Maps

Switch#show access-list
Extended MAC access list mac1
deny any any decnet-iv
permit any any
Switch#show vlan access-map
Vlan access-map "map_1" 10
Match clauses:
ip address: ip1
Action:
drop
Vlan access-map "map_1" 20
Match clauses:
mac address: mac1
Action:
forward
Vlan access-map "map_1" 30
Match clauses:
Action:
drop
Switch#show vlan filter
VLAN Map map_1 is filtering VLANs:
20-22
1439_CCNP_3.book Page 88 Wednesday, October 27, 2004 9:54 AM

88 Chapter 2: VLANs and VTP

Lab 2.9.4 Catalyst 2950 and 3550 Series Intra-VLAN Security


In this lab exercise, you configure intra-VLAN security with ACLs using command-
line interface (CLI) mode.

Using VLAN Maps with Router ACLs


To filter both bridged and routed traffic, VLAN maps can be used by themselves or in con-
junction with router ACLs. Router ACLs can be applied on both input and output routed
VLAN interfaces, and a VLAN map can be used to filter the bridged traffic.
If a packet flow matches a VLAN map deny clause in the ACL, regardless of the router ACL
configuration, the packet is dropped.
When using router ACLs with VLAN maps, packets that require logging on the router ACLs
are not logged if they are denied by a VLAN map.
Remember, VLAN maps have a default action of forward, so a packet is forwarded if it does
not match any VLAN map entry.
These guidelines are for configurations where a router ACL and a VLAN map need to be
applied on the same VLAN. These guidelines do not apply to configurations where router
ACLs and VLAN maps are used on different VLANs.
The switch hardware provides one lookup for security ACLs for each direction, input and
output. As a result, a router ACL and a VLAN map must be merged when they are configured
on the same VLAN.
Merging the router ACL with the VLAN map might significantly increase the number of ACEs.
If a router ACL and a VLAN map must be configured on the same VLAN, use the following
guidelines for both router ACL and VLAN map configuration:
■ Whenever possible, try to write the ACL with all entries having a single action except
for the final default action of the other type. That is, write the ACL using one of these
two forms:
permit...
permit...
permit...
deny ip any any

or
deny...
deny...
deny...
permit ip any any
1439_CCNP_3.book Page 89 Wednesday, October 27, 2004 9:54 AM

VLAN Security 89

■ To define multiple permit and deny actions in an ACL, group each action type to reduce
the number of entries.
■ Avoid including Layer 4 information in an ACL.
■ Use wildcard masks in the IP address whenever possible.
The best merge results are obtained if the ACLs are filtered based on source or destination IP
addresses and not on the full flow (source IP address, destination IP address, protocol, and
protocol ports). If the full flow must be specified, and the ACL contains both IP ACEs and
TCP/UDP/ICMP ACEs with Layer 4 information, put the Layer 4 ACEs at the end of the list.
This gives priority to the filtering of traffic based on IP addresses.
ACL processing in the 3550 switch is done mostly in hardware, but if the hardware exceeds
its capacity to store ACL configurations, the switch software attempts to fit a simpler configu-
ration into hardware. This simpler configuration does not do all the filtering that has been
configured, but instead sends some or all packets to the CPU to be filtered by software. All
configured filtering is accomplished, but performance is greatly decreased when the filtering
is done in software.
Any problem in fitting the configuration into hardware is logged, but it is possible that not
everyone who configures the switch can see the log messages as they occur. The show fm
command displays feature manager information for the interface or the VLAN. The show fm
vlan vlan-id and show fm interface interface-id commands can be executed from privileged
mode to determine if any interface or VLAN configuration did not fit into hardware.
Example 2-8 shows some sample output.

Example 2-8 An ACL Configuration Conflict Exists

Switch#show fm vlan 1
Conflicts exist with layer 2 access groups.
Input VLAN Label:1
Output VLAN Label:0 (default)
Priority:normal

The show fm command is also used to determine what label is used in the hardware for the
interface or VLAN configuration. VLAN labels are used for features configured on VLANs,
such as router ACLs and VLAN maps. The VLAN label ID range is from 0 to 255. The show
fm vlan-label label-id command displays what features associated with that label cannot fit
in the hardware or if configuration conflicts have occurred, as shown in Example 2-9.
1439_CCNP_3.book Page 90 Wednesday, October 27, 2004 9:54 AM

90 Chapter 2: VLANs and VTP

Example 2-9 A Merge Failure on an Input Access Group

Switch#show fm vlan-label 1
Unloaded due to merge failure or lack of space:
InputAccessGroup
Merge Fail:input
Input Features:
Interfaces or VLANs: Vl1
Priority:normal
Vlan Map:(none)
Access Group:131, 6788 VMRs
Multicast Boundary:(none), 0 VMRs
Output Features:
Interfaces or VLANs:
Priority:low
Bridge Group Member:no
Vlan Map:(none)
Access Group:(none), 0 VMRs

Applying Router ACLs and VLAN Maps on VLANs


This section contains examples of applying router ACLs and VLAN maps to a VLAN for
switched, bridged, routed, and multicast packets. Although the following figures show pack-
ets being forwarded to their destination, each time the packet’s path crosses a line indicating
a VLAN map or an ACL, it is also possible that the packet might be dropped rather than
forwarded.
Packets switched within the VLAN without being routed are subject only to the VLAN map
of the input VLAN, as shown in Figure 2-12.
For routed packets, the ACLs are applied in the following order, as shown in Figure 2-13:
1. VLAN map for input VLAN

2. Input router ACL

3. Output router ACL

4. VLAN map for output VLAN


1439_CCNP_3.book Page 91 Wednesday, October 27, 2004 9:54 AM

VLAN Security 91

Figure 2-12 Switched Packets Are Affected Only by VLAN Maps

Catalyst 3550 Switch

Input Output
VLAN 10 Router Router VLAN 20
Map ACL ACL Map

Frame

Host A
(VLAN 10)
Routing Function or
Fall Back Bridge

Host C
(VLAN 10)
VLAN 10 VLAN 20
Packet

Figure 2-13 Routed Packets Can Be Filtered by Multiple VLAN Maps and Incoming and
Outgoing ACLs

Catalyst 3550 Switch with Enhanced Multilayer Switch Image

Input Output
VLAN 10 Router Router VLAN 20
Map ACL ACL Map

Frame

Host A Host B
(VLAN 10) (VLAN 20)
Routing Function

VLAN 10 Packet VLAN 20


1439_CCNP_3.book Page 92 Wednesday, October 27, 2004 9:54 AM

92 Chapter 2: VLANs and VTP

A multicast packet that is being routed has two different types of filters applied:
■ One for destinations that are other ports in the input VLAN
■ Another for each of the destinations that are in other VLANs to which the packet has
been routed
The packet might be routed to more than one output VLAN, in which case a different router
output ACL and VLAN map would apply for each destination VLAN, as shown in Figure 2-14.

Figure 2-14 Multicast Packets Are Subject to VLAN Maps and Might Also Be Subject to ACLs,
Depending on Their Destination

Catalyst 3550 Switch with Enhanced Multilayer Switch Image

Input Output
VLAN 10 Router Router VLAN 20
Map ACL ACL Map

Frame

Host A Host B
(VLAN 10) (VLAN 20)
Routing Function

Host C
(VLAN 10)
VLAN 10 Packet VLAN 20

The final result is that the packet might be permitted in some of the output VLANs and not in
others. A copy of the packet is forwarded to destinations where it is permitted. However, if
the input VLAN map drops the packet, no destination receives a copy of the packet.

VLAN Types
VLANs can be implemented in various ways. This section describes different types of VLAN
implementations. First, campus-wide VLANs versus local VLANs are explored, followed by
static VLANs versus dynamic VLANs.
1439_CCNP_3.book Page 93 Wednesday, October 27, 2004 9:54 AM

VLAN Types 93

VLAN Boundaries
Just as routing protocols are classified in various ways, so are VLANs. VLANs are classified
as local (geographic) or end-to-end (campus-wide). Alternatively, VLANs are classified as
either port-based (static) or dynamic.
The number of VLANs in the switch block might vary greatly, depending on several factors:
■ Traffic patterns
■ Types of applications
■ Network management needs
■ Group commonality
In addition, an important consideration in defining the size of the switch block and the num-
ber of VLANs is the IP addressing scheme.
For example, suppose a network uses a 24-bit mask to define a subnet. Given this criterion, a
total of 254 host addresses are allowed in one subnet. Because a one-to-one correspondence
between VLANs and IP subnets is strongly recommended, there can be no more than 254 devices
in any one VLAN. It is further recommended that VLANs should not extend outside the
Layer 2 domain of the distribution switch. With many users spread across three departments
in one building, four VLANs would be required under the recommended constraints, as
shown in Figure 2-15.

Figure 2-15 Modern Campus Networks Employ a One-to-One Correspondence Between IP Subnets
and VLANs

Management Routing Function


VLAN Interconnects VLANs

Network Layer 192.26.21.0 192.20.24.0 192.30.20.0

Engineering Marketing Sales


Data-Link Layer
VLAN VLAN VLAN
Broadcast
Domains

Physical Layer
LAN Switch

Human Layer
1439_CCNP_3.book Page 94 Wednesday, October 27, 2004 9:54 AM

94 Chapter 2: VLANs and VTP

When scaling VLANs in the switch block, there are two basic methods of defining the VLAN
boundaries:
■ End-to-end VLANs
■ Local VLANs

End-to-End VLANs
VLANs can exist either as end-to-end networks (campus-wide) or inside limited geographic
(local) boundaries. An end-to-end VLAN network has the following characteristics:
■ Users are grouped into VLANs independent of physical location and dependent on
group or job function.
■ All users in a VLAN should have the same 80/20 traffic flow patterns.
■ As a user moves around the campus, VLAN membership for that user should not
change.
■ Each VLAN has a common set of security requirements for all members.
Backbone links in a switched LAN should be faster than access level links, as shown in Fig-
ure 2-16. Starting in the wiring closet, 100-Mbps dedicated Ethernet ports are provisioned for
each user. Each VLAN corresponds to a subnet and, because people have moved around over
time, each switch eventually becomes a member of all VLANs. Fast Ethernet Inter-Switch
Link (ISL) or IEEE 802.1Q is used to carry multiple VLAN information between the wiring
closets and the distribution layer switches.

Figure 2-16 Uplinks Should Provide Greater Bandwidth Than Access Links
Accounting Engineering Accounting Accounting Engineering Sales
VLAN 10 VLAN 20 VLAN 10 VLAN 10 VLAN 20 VLAN 30
172.16.10.0/24 172.16.20.0/24 172.16.10.0/24 172.16.10.0/24 172.16.20.0/24 172.16.30.0/24

Gigabit Uplinks

VLAN Trunk

ISL is a Cisco-proprietary protocol that maintains VLAN information as traffic flows between
switches and routers. IEEE 802.1Q is an open-standard VLAN tagging mechanism that pre-
dominates in modern switching installations. VLAN tagging mechanisms are explored later
in this chapter in the section “VLAN Identification.”
1439_CCNP_3.book Page 95 Wednesday, October 27, 2004 9:54 AM

VLAN Types 95

Workgroup servers operate in a client/server model, and attempts have been made to keep
users in the same VLAN as their server to maximize the performance of Layer 2 switching,
and keep traffic localized.
In the core, a router allows intersubnet communication. The network is engineered in the
campus-wide VLAN model, based on traffic flow patterns, to have 80 percent of the traffic
within a VLAN and 20 percent crossing the router to the enterprise servers and to the Internet
and WAN. End-to-end VLANs allow devices to be grouped based on resource usage. This
includes such parameters as server usage, project teams, and departments. The goal of end-
to-end VLANs is to maintain 80 percent of the traffic on the local VLAN.
As corporate networks move to centralize their resources, end-to-end VLANs have become
more difficult to maintain. Users are required to use many different resources, many of which
are no longer in their VLAN. Because of this shift in placement and usage of resources,
VLANs now are frequently created around geographic (local) boundaries rather than
commonality boundaries.

Local VLANs
The local VLAN model has VLANs dedicated to each access layer switch cluster, with Layer 3 NOTE
switching between wiring closets performed at the distribution layer or Main Distribution Facility If an access layer
switch has only users
(MDF), as shown in Figure 2-17. With the campus-wide VLAN model, users who are in the
who belong to a single
same department would be in the same VLAN regardless of the location of the VLAN in the VLAN, it is not neces-
network. In the local VLAN model, users in the same department are in the same VLAN only if sary to configure those
interfaces for the spe-
their access layer switches are connected to the same distribution layer switch (see Figure 2-17). cific VLAN. However,
If the access layer switch is connected to a different distribution layer switch, the users are some network adminis-
trators assign these
assigned a different VLAN ID and subnet address, regardless of the users’ department.
interfaces to their
proper VLAN in case
Figure 2-17 Local VLANs Are Based on Physical Location and Are Dedicated to an Access Layer the switch has other
Switch Cluster. Accounting Users on Different Layer 3 Switches Can Be on Different VLANs configured on
VLANs. it in the future (see
Accounting Engineering Accounting Accounting Engineering Sales Figure 2-18).
VLAN 10 VLAN 20 VLAN 10 VLAN 30 VLAN 40 VLAN 50
172.16.10.0/24 172.16.20.0/24 172.16.10.0/24 172.16.30.0/24 172.16.40.0/24 172.16.50.0/24

Gigabit Uplinks

172.16.100.0/24
1439_CCNP_3.book Page 96 Wednesday, October 27, 2004 9:54 AM

96 Chapter 2: VLANs and VTP

Figure 2-18 Access Uplinks Do Not Carry VLAN Tags, So Access Ports Can Be Left with Their
Default VLAN Configuration
Accounting Engineering Accounting Accounting Engineering Sales
VLAN 10 VLAN 20 VLAN 10 VLAN 30 VLAN 40 VLAN 50
172.16.10.0/24 172.16.20.0/24 172.16.10.0/24 172.16.30.0/24 172.16.40.0/24 172.16.50.0/24

VLAN Non-
Interfaces on Trunk Trunk Interfaces on the
the Switch Must Switch Do Not Need
Be Configured To Be Configured
for VLANs for VLANs

172.16.100.0/24

Geographic VLANs are also considerably easier to manage and conceptualize than VLANs
that span different geographic areas.

Establishing VLAN Memberships


The two common approaches to assigning VLAN membership are as follows:
■ Static VLANs
■ Dynamic VLANs
Static VLANs are also called port-based VLANs. Static VLAN assignments are created by
manually assigning ports to a VLAN. As a device enters the network, the device automati-
cally assumes the port’s VLAN. If the user changes ports and needs access to the same
VLAN, the network administrator must manually make a port-to-VLAN assignment for the
new connection.
Dynamic VLANs are created through the use of software packages such as CiscoWorks 2000.
With a VLAN Management Policy Server (VMPS), an administrator can assign switch ports
to VLANs dynamically based on information such as the source MAC address of the device
connected to the port or the username used to log on to that device. As a device enters the net-
work, the device queries a database for VLAN membership. Figure 2-19 illustrates a VMPS
setup.

Port-Based VLAN Membership


With port-based VLAN membership, the port is assigned to a specific VLAN independent of
the user or system attached to the port. This means that all users attached to the port should be
members of the same VLAN, as shown in Figure 2-20. The network administrator typically
performs the VLAN assignment. The port configuration is static and cannot be automatically
changed to another VLAN without manual reconfiguration.
1439_CCNP_3.book Page 97 Wednesday, October 27, 2004 9:54 AM

VLAN Types 97

Figure 2-19 VMPS Lets Ports Be Automatically Assigned VLAN Membership

Catalyst 6500 TFTP Server

Primary VMPS
172.20.26.150
Server 1 Switch 1
Client
172.20.22.7
172.20.26.151
Switch 2

Secondary 172.20.26.152
VMPS Server 2 Switch 3

Ethernet Segment
172.20.26.153
Switch 4

End
Station 1 172.20.26.154
Switch 5

172.20.26.155
Switch 6

172.20.26.156
Switch 7

End
172.20.26.157
Station 2 Switch 8
Client
172.20.26.158
Switch 9

Secondary
172.20.26.159
VMPS Server 3 Switch 10

Figure 2-20 All Users Attached to the Same Switch Port Must Be in the Same VLAN

Management Routing Function


VLAN Interconnects VLANs

Network Layer 192.26.21.0 192.20.24.0 192.30.20.0

Engineering Marketing Sales


Data-Link Layer
VLAN VLAN VLAN
Broadcast
Domains

Physical Layer
LAN Switch

Human Layer
1439_CCNP_3.book Page 98 Wednesday, October 27, 2004 9:54 AM

98 Chapter 2: VLANs and VTP

As with other VLAN approaches, the packets forwarded using this method do not leak into
other VLAN domains on the network. After a port has been assigned to a VLAN, the port
cannot send to or receive from devices in another VLAN without the intervention of a
Layer 3 device.
The device that is attached to the port likely doesn’t understand that a VLAN exists. The
device simply knows that it is a member of a subnet and that the device should be able to talk
to all other members of the subnet by simply sending information to the cable segment. The
switch is responsible for identifying that the information came from a specific VLAN and for
ensuring that the information gets to all other members of the VLAN. The switch is further
responsible for ensuring that ports in a different VLAN do not receive the information.
This approach is quite simple, fast, and easy to manage because no complex lookup tables are
required for VLAN segmentation. If port-to-VLAN association is done with an application-
specific integrated circuit (ASIC), the performance is very good. An ASIC allows the port-to-
VLAN mapping to be done at the hardware level.

Dynamic VLANs
With a VMPS, ports can be assigned to VLANs dynamically, based on information entered in
the VMPS database. When a host moves from a port on one switch in the network to a port on
another switch in the network, the switch assigns the new port to the proper VLAN for that
host dynamically.
When VMPS is enabled, a MAC address-to-VLAN mapping database downloads from a
TFTP server, and VMPS begins to accept client requests. If the switch is power-cycled or
reset, the VMPS database downloads from the TFTP server automatically, and VMPS is
reenabled.
VMPS opens a UDP socket to communicate and listen to client requests. When the VMPS
server receives a valid request from a client, it searches its database for a MAC address-to-
VLAN mapping. Figure 2-21 illustrates primary and secondary VMPS servers.
If the assigned VLAN is restricted to a group of ports, VMPS verifies the requesting port
against this group. If the VLAN is allowed on the port, the VLAN name is returned to the
client. If the VLAN is not allowed on the port and VMPS is not in secure mode, the host
receives an access-denied response. If VMPS is in secure mode, the port is shut down.
If a VLAN in the database does not match the current VLAN on the port and active hosts are
on the port, VMPS sends an access-denied or port-shutdown response based on the secure
mode of the VMPS.
1439_CCNP_3.book Page 99 Wednesday, October 27, 2004 9:54 AM

VLAN Types 99

Figure 2-21 VMPS Servers Process Client Requests for MAC-to-VLAN Maps

Catalyst 6500 TFTP Server

Primary VMPS
172.20.26.150
Server 1 Switch 1
Client
172.20.22.7
172.20.26.151
Switch 2

Secondary 172.20.26.152
VMPS Server 2 Switch 3

Ethernet Segment
172.20.26.153
Switch 4

End
Station 1 172.20.26.154
Switch 5

172.20.26.155
Switch 6

172.20.26.156
Switch 7

End
172.20.26.157
Station 2 Switch 8
Client
172.20.26.158
Switch 9

Secondary
172.20.26.159
VMPS Server 3 Switch 10

Multiple hosts can be active on a dynamic port if they are all in the same VLAN. If the link
goes down on a dynamic port, the port returns to an isolated state. Any hosts that come online
through the port are checked again with VMPS before the port is assigned to a VLAN.
The following guidelines and restrictions apply to dynamic port VLAN membership:
■ VMPS must be configured before the ports can be configured as dynamic.
■ When a port is configured as dynamic, Spanning Tree PortFast is enabled automatically
for that port.
■ If a port is converted from static to dynamic on the same VLAN, the port connects
immediately to that VLAN, but VMPS eventually checks the host’s legality on the port.
■ Static secure ports cannot become dynamic ports unless security is disabled before the
port is made dynamic.
■ Static ports that are trunking cannot become dynamic ports unless trunking is disabled
on the port before it is changed from static to dynamic.
It is also important to note that the VLAN Trunking Protocol (VTP) management domain
and the management VLAN of VMPS clients and the VMPS server must be the same.
1439_CCNP_3.book Page 100 Wednesday, October 27, 2004 9:54 AM

100 Chapter 2: VLANs and VTP

Configuring VLANs and VMPS


A static VLAN is easy to configure and is by far the most common method of configuring
VLAN membership. Dynamic VLANs with VMPS is another option, but Cisco is no longer
recommending it as a preferred solution. This section describes static and dynamic VLAN
configurations.

Configuring Static VLANs


Static VLANs are ports on a switch that are manually assigned to a VLAN by using a VLAN
management application or by working directly within the switch. These ports maintain their
assigned VLAN configuration until an administrator changes them. Although static VLANs
require manual entry changes, they are secure, easy to configure, and straightforward to mon-
itor. This type of VLAN works well in networks where moves are controlled and managed.
Static VLANs are also appropriate for networks that employ robust VLAN management soft-
ware to configure the ports. Static VLANs are also a consideration if it is undesirable to
assume the additional overhead required when maintaining end-station MAC addresses and
custom filtering tables.
The creation of a VLAN on a switch is a very straightforward and simple task. If you’re using
a Cisco IOS-based switch, from interface configuration mode, issue the switchport com-
mand. The switchport mode [access | dynamic | trunk] command can be used to set the
interface to access, dynamic, or trunk.
To statically assign an interface to a VLAN, use the switchport mode access command
followed by the switchport access vlan number command.
To set interface FastEthernet 0/3 on a Catalyst switch to access mode, use the switchport
mode IOS command. The port is then assigned to VLAN 2 with the switchport access vlan
command, as verified in Example 2-10 using the show running-config command. The
switchport mode access command is the default mode for switch interfaces. The mode is
not shown in the running configuration.

Example 2-10 The switchport access vlan Command Is Used to Statically Configure a Port for a
Particular VLAN

Switch#show running-config
hostname switch
!
ip subnet-zero
!
1439_CCNP_3.book Page 101 Wednesday, October 27, 2004 9:54 AM

Configuring VLANs and VMPS 101

Example 2-10 The switchport access vlan Command Is Used to Statically Configure a Port for a
Particular VLAN (Continued)

!
!
interface FastEthernet0/1
!
interface FastEthernet0/2
!
interface FastEthernet0/3
switchport access vlan 2

Unlike the earlier 2900XL and 3500XL switches, the 2950 switches with Cisco IOS Release
12.1(6)EA2 or later and the 3550 switches with Cisco IOS Release 12.1(4)EA1 or later have
an interface range command that lets multiple interfaces be identified for a subsequent oper-
ation. For example, several ports can be assigned to a VLAN with one switchport command,
as shown in Example 2-11.

Example 2-11 The interface range Command Is Definitely a Time-Saver!

Switch(config)#interface range fa0/1 - 6


Switch(config-if-range)#switchport access vlan 10

These commands assign ports 1 to 6 to VLAN 10 in one command sequence.


Ports on Cisco switches usually default to the Dynamic Trunking Protocol (DTP) mode of
dynamic desirable. This means that another switch connected to this port can cause trunking
to occur on this interface. It is recommended that all nontrunking switch ports be configured
as access ports with the command switchport mode access. This helps prevent certain man-
in-the-middle attacks from occurring within the network. There are also other reasons why it
is important not to have rogue switches attaching to the network in regard to STP. Chapter 3,
“Spanning Tree Protocol (STP),” discusses these issues in greater detail.

Lab 2.9.1 Catalyst 2950T and 3550 Series Static VLANS


In this lab exercise, you create and maintain VLANs on a Cisco Catalyst 2950T or
3550 series Ethernet switch using CLI mode.
1439_CCNP_3.book Page 102 Wednesday, October 27, 2004 9:54 AM

102 Chapter 2: VLANs and VTP

Verifying VLAN Configuration


As soon as a switch has been configured for VLANs, you should verify the configuration
with the show vlan or show vlan brief command. The output in Example 2-12 shows that
VLAN 2 is configured on interface FastEthernet 0/3.

Example 2-12 The show vlan brief Command Provides a Quick List of VLANs and Associated Ports

Switch#show vlan brief


VLAN Name Status Ports
---- ------------------ ------ -------------------------_
1 default active Fa0/1, Fa0/2, Fa0/4, Fa0/5
Fa0/6, Fa0/7, Fa0/8, Fa0/9
Fa0/10, Fa0/11, Fa0/12, Fa0/13
Fa0/14, Fa0/15, Fa0/16, Fa0/17
Fa0/18, Fa0/19, Fa0/20, Fa0/21
Fa0/22, Fa0/23, Fa0/24,

2 VLAN0002 active Fa0/3


1002 fddi-default active
1003 token-ring-default active
1004 fddinet-default active
1005 trnet-default active

When configuring VLANs, keep the following in mind:


■ A created VLAN remains unused until it is mapped to switch ports.
■ The default configuration has all the switch ports on VLAN 1.

Deleting VLANs
When a VLAN is deleted from a switch that is in VTP server mode, the VLAN is removed
from all switches in the VTP domain. When a VLAN is deleted from a switch that is in VTP
transparent mode, the VLAN is deleted only on that specific switch. A VLAN cannot be
deleted from a switch that is in VTP client mode. The later section “VLAN Trunking Protocol
(VTP)” covers the different VTP modes in greater detail.
The default VLANs for the different media types cannot be deleted. Ethernet VLAN 1, Fiber
Distributed Data Interface (FDDI), and Token Ring VLANs 1002 to 1005 cannot be removed
from the switch.
1439_CCNP_3.book Page 103 Wednesday, October 27, 2004 9:54 AM

Configuring VLANs and VMPS 103

Beginning in privileged EXEC mode, follow the steps listed in Table 2-3 to delete a VLAN CAUTION
on the switch. When a VLAN is
deleted, any ports
assigned to that VLAN
Table 2-3 VLANs Can Be Removed in VLAN Database Configuration Mode
become inactive. They
remain associated with
Step Command Description
the deleted VLAN until
they are assigned to a
1 vlan database Enters VLAN configuration mode.
new VLAN. Use cau-
tion when deleting
2 no vlan vlan-id Removes the VLAN by entering the
VLANs. It is possible
VLAN ID. to cause a major loss of
connectivity by acci-
3 exit Updates the VLAN database, propagates it dentally eliminating a
throughout the administrative domain, and VLAN that still has
returns to privileged EXEC mode. active users on it.

4 show vlan brief Verifies the VLAN removal.


5 copy running-config startup-config (Optional) Saves the configuration file.

It is important to note that the no vlan command must be issued on a switch in VTP server or
VTP transparent mode. VLANs cannot be deleted from a VTP client switch. If the switch is
configured in transparent mode, you can delete the VLAN. VLANs deleted from a switch in
VTP transparent mode are removed from that one switch only and not throughout the VTP
domain. VTP domains are covered in the later section “VLAN Trunking Protocol (VTP).”

VMPS Operation
With VLAN Membership Policy Server (VMPS), switch ports can be assigned to VLANs
dynamically, based on the source MAC address or user ID of the device connected to the port.
When a host or user moves from a port on one switch in the network to a port on another
switch in the network, the switch dynamically assigns the new port to the proper VLAN for
that host.
When VMPS is enabled, a MAC address-to-VLAN mapping database downloads from a
TFTP server to the VMPS server (a Catalyst switch). The VMPS server then begins accepting
client requests.
The VMPS client communicates with a VMPS server through the VLAN Query Protocol
(VQP). When the VMPS receives a VQP request from a client switch, it searches its database
for a MAC-address-to-VLAN mapping.
The server response is based on this mapping and whether the server is in secure mode.
Secure mode determines whether the server shuts down the port when a VLAN is not allowed
on it or just denies the port access to the VLAN.
1439_CCNP_3.book Page 104 Wednesday, October 27, 2004 9:54 AM

104 Chapter 2: VLANs and VTP

In response to a request, the VMPS takes one of these actions:


■ If the assigned VLAN is restricted to a group of ports, the VMPS verifies the requesting
port against this group and responds as follows:
— If the VLAN is allowed on the port, the VMPS sends the VLAN name to the cli-
ent in response.
— If the VLAN is not allowed on the port and the VMPS is not in secure mode, the
VMPS sends an access-denied response.
— If the VLAN is not allowed on the port and the VMPS is in secure mode, the
VMPS sends a port-shutdown response.
■ If the VLAN in the database does not match the current VLAN on the port and active
hosts exist on the port, the VMPS sends an access-denied or port-shutdown response,
depending on the secure mode of the VMPS.
If the switch receives an access-denied response from the VMPS, it continues to block traffic
from the MAC address to or from the port. The switch continues to monitor the packets
directed to the port and sends a query to the VMPS when it identifies a new address. If the
switch receives a port-shutdown response from the VMPS, it disables the port. The port must
then be enabled manually.
It is also possible to configure a fallback VLAN name. If a device is plugged into the network
and its MAC address is not in the database, VMPS sends the fallback VLAN name to the
client. If no fallback VLAN is configured and the MAC address does not exist in the database,
VMPS sends an access-denied response. If VMPS is in secure mode, it sends a port-shutdown
response.
An administrator can also make an explicit entry in the configuration table to deny access to
specific MAC addresses for security reasons by specifying a --NONE-- keyword for the
VLAN name. In this case, VMPS sends an access-denied or port-shutdown response.

Dynamic Port VLAN Membership


A dynamic port on the switch can belong to only one VLAN. When the link comes up, the
switch does not forward traffic to or from this port until the VMPS server provides the VLAN
assignment. The VMPS client receives the source MAC address from the first packet of a new
host connected to the dynamic port and attempts to match the MAC address to a VLAN in the
VMPS database via a VQP request to the VMPS server.
1439_CCNP_3.book Page 105 Wednesday, October 27, 2004 9:54 AM

Configuring VLANs and VMPS 105

If there is a match, the VMPS server sends the VLAN number for that port. If the client
switch was not previously configured, it uses the domain name from the first VTP packet it
receives on its trunk port from the VMPS. If the client switch was previously configured, it
includes its domain name in the query packet to the VMPS to obtain its VLAN number. The
VMPS verifies that the domain name in the packet matches its own domain name before
accepting the request and responds to the client with the assigned VLAN number for the client.
If there is no match, the VMPS either denies the request or shuts down the port, depending on
the VMPS secure mode setting.
Multiple hosts can be active on a dynamic port if they are all in the same VLAN, but the
VMPS shuts down a dynamic port if more than 20 hosts are active on the port for a Catalyst
2950 or 3550 switch. The total number of allowable hosts varies by platform.
If the link goes down on a dynamic port, the port returns to an isolated state and does not
belong to a VLAN. Any hosts that come online through the port are checked again through
VQP request with the VMPS before the port is assigned to a VLAN.

VMPS Configuration Guidelines


There are several restrictions for configuring VMPS client switch ports as dynamic. The fol-
lowing requirements apply to dynamic port VLAN membership:
■ VMPS must be configured before ports can be set as dynamic.
■ The VTP management domain of the VMPS clients and the VMPS server must be the
same.
■ The management VLAN of VMPS clients and the VMPS server must be the same.
■ When a port is configured as dynamic, the Spanning Tree Port Fast feature is automati-
cally enabled for that port.
■ After a static port is converted to dynamic on the same VLAN, the port connects imme-
diately to that VLAN until VMPS checks its database for the legality of the specific
host on the dynamic port.
■ Static ports cannot become dynamic ports.
■ Static ports that are trunking cannot become dynamic ports.
■ Physical ports in an EtherChannel cannot be configured as dynamic ports.
■ VMPS shuts down a dynamic port when too many active hosts connect to a port.
To use VMPS, a VMPS database must be created and stored on a TFTP server.
1439_CCNP_3.book Page 106 Wednesday, October 27, 2004 9:54 AM

106 Chapter 2: VLANs and VTP

A VMPS database configuration file is an ASCII text file that is stored on a TFTP server
accessible to the switch configured as the VMPS server, as shown in Example 2-13.

Example 2-13 A TFTP Server Stores the ASCII VMPS Database File. The VMPS Server Pulls the VLAN-to-MAC
Address Mappings from the TFTP Server.

!VMPS FILE FORMAT, version 1.1


!Always begin the configuration file with the word "VMPS"
!
!vmps domain <domain-name>
!The VMPS domain must be defined.
!vmps mode {open | secure}
!The default mode is open.
!vmps fallback <vlan-name>
!vmps no domain-req {allow | deny}
!
!The default value is allow. Deny means requests from
!clients with no domain name are rejected.
vmps domain wBU
vmps mode open
vmps fallbackback default
vmps no-domain-req deny
!
!
!MAC Addresses
!
vmps-mac-addrs
!
!address <addr> vlan-name <vlan_name>
!
address 0012.2233.4455 vlan-name hardware
address 0000.6509.a080 vlan-name hardware
address aabb.ccdd.eeff vlan-name Green
address 1223.5678.9abc vlan-name ExecStaff
address fedc.ba98.7654 vlan-name -NONE-
address fedc.ba23.1245 vlan-name Purple
!
!Port Groups
!
1439_CCNP_3.book Page 107 Wednesday, October 27, 2004 9:54 AM

Configuring VLANs and VMPS 107

The VMPS parser is line-based. Each entry in the text file starts on a new line.
Ranges are not allowed for the switch port numbers. It is probably easiest to take a sample
VMPS database file and edit it to meet the network’s needs.
Although it is rarely done, a VMPS database file can be created from scratch using these
rules:
■ Begin the configuration file with the word “VMPS” to prevent other types of configura-
tion files from being read incorrectly by the VMPS server.
■ Define the VMPS domain.
■ Define the security mode as either open (the default) or secure mode.
■ Define a fallback VLAN (optional).
■ Define the MAC address-to-VLAN name mappings.
■ Define port groups to which VMPS will be applied, using groups, individual ports, or
the all-ports keyword.
■ Define VLAN groups to which VLAN port policies will be applied.
■ Define VLAN port policies to associate ports with a restricted VLAN.
To review the general mechanism by which VMPS makes policy decisions affecting switch
ports and VLAN assignments, review the earlier section “VMPS Operation.” Here’s a sum-
mary of the sample VMPS configuration file:
■ The security mode is open.
■ The default is used for the fallback VLAN.
■ MAC address-to-VLAN name mappings provide the MAC address of each host, and
the VLAN to which each host belongs is defined.
■ Port groups are defined.
■ VLAN groups are defined.
■ VLAN port policies are defined for the ports associated with restricted VLANs.
To create a VMPS database, do the following:
Step 1 Determine the MAC addresses of the hosts that will be assigned to VLANs
dynamically, and determine the VMPS mode.
Step 2 Map out the port groups, VLAN groups, port policies, and fallback VLAN.
Step 3 Create an ASCII text file that contains the MAC address-to-VLAN mappings
and policies.
Step 4 Move the ASCII text file to a TFTP server so that it can be downloaded to the
switch that will act as the VMPS server.
1439_CCNP_3.book Page 108 Wednesday, October 27, 2004 9:54 AM

108 Chapter 2: VLANs and VTP

As soon as the VMPS database is in place on the TFTP server, the VMPS server and clients
can be configured. If a network interface card (NIC) in a PC changes, the VMPS database
needs to be updated.
Recall that when VMPS is enabled, the switch downloads the VMPS database from the TFTP
server and begins accepting VMPS requests from VMPS clients.
Configure VMPS clients with the commands shown in Example 2-14, starting in global con-
figuration mode.

Example 2-14 The switchport access vlan dynamic Command Enables Dynamic VLAN Assignment to a Port

Switch#configure terminal
Switch(config)#vmps server ipaddress primary
Switch(config)#vmps server ipaddress for up to 3 secondary VMPS servers (optional)
Switch(config)#interface interface-id
Switch(config-if)#switchport mode access
Switch(config-if)#switchport access vlan dynamic

Repeat the last three commands for each dynamic switch port. To reenable a shut-down
dynamic port, enter the interface configuration command no shutdown.
Now that all the VMPS components are configured and in place, verify that everything is
working correctly.
Use the show vmps command to verify the VMPS server entry. This command did not
become available on some IOS-based switch platforms until Cisco IOS Release 12.1(6). The
show vmps command displays the VQP version and the VMPS server IP addresses, including
which server is the primary. Use the statistics keyword to display client-side statistics.
Use the command show interface interface-id switchport to verify dynamic assignment of
VLAN membership to a given port.
After the database has loaded, a VMPS server switch answers queries from VMPS client
switches with dynamic ports. The following assumptions apply to the scenario pictured in
Figure 2-22:
■ The VMPS server and the VMPS client are separate switches.
■ Switch 1 is the primary VMPS server.
■ Switch 3 and Switch 10 are secondary VMPS servers.
■ End stations are connected to these clients:
— Switch 5
— Switch 8
■ The database configuration file is called Bldg-G.db and is stored on a TFTP server with
IP address 172.20.22.7.
1439_CCNP_3.book Page 109 Wednesday, October 27, 2004 9:54 AM

Configuring VLANs and VMPS 109

Figure 2-22 The TFTP Server, the VMPS Server(s), the VMPS Clients, and the VQP Work in Concert
to Provide Dynamic VLAN Assignment to Ports

Catalyst 6500 Router TFTP Server

Primary VMPS
172.20.26.150
Server 1 Switch 1
Client
172.20.22.7
172.20.26.151
Switch 2

Catalyst 6000 6000

Secondary
172.20.26.152
VMPS Server 2 Switch 3

Ethernet Segment
172.20.26.153
Switch 4

End
Station 1 172.20.26.154
Switch 5

172.20.26.155
Switch 6

172.20.26.156
Switch 7

End
172.20.26.157
Station 2 Switch 8
Client
172.20.26.158
Switch 9

Catalyst 6000 6000

Secondary
Switch 10 172.20.26.159
VMPS Server 3

Access Links and Trunk Links


Static switch ports run in either access or trunk mode. Accordingly, the links connected to
these switch ports are called access links or trunk links. In access mode, the port belongs to
one and only one VLAN. An access port is a switch port that connects to an end-user device
or a server; the frames transmitted on an access link look like any other Ethernet frames.
A trunk link differs from an access link in that it can support multiple VLANs. The VLANs
are multiplexed over the link with a trunking protocol. The trunk link also does not belong to
a specific VLAN. Trunk links are typically used to connect switches to other switches, routers,
or a server that uses an IEEE 802.1Q-enabled network card to participate in multiple VLANs.
1439_CCNP_3.book Page 110 Wednesday, October 27, 2004 9:54 AM

110 Chapter 2: VLANs and VTP

Trunks can extend VLANs across an entire network. A trunk link can be configured to trans-
port all VLANs or a restricted set of VLANs. Trunk links are typically configured on ports
that support the greatest bandwidth for a given switch. Catalyst switches support trunk links
on Fast Ethernet, Gigabit Ethernet, and 10 Gigabit Ethernet ports.
To multiplex VLAN traffic, special protocols exist that encapsulate or tag the frames so that
the receiving device can determine the frame’s VLAN membership. The Cisco-proprietary
ISL protocol lets Cisco devices multiplex VLANs between Cisco devices. In multivendor
environments, switches must use IEEE 802.1Q, an industry-standard protocol that permits
multiplexing of VLANs over trunk links. The Catalyst 3550 switches support both ISL and
802.1Q, and the Catalyst 2950 switch supports only 802.1Q.
Without trunk links, multiple access links would have to be installed to support multiple
VLANs between switches (one link per VLAN). This is clearly neither a cost-effective nor
scalable solution. Trunking is absolutely essential for interconnecting switches in a campus
network. Figure 2-23 illustrates access and trunk links.

Figure 2-23 Access and Trunk Links Link All the Devices in a Campus Network

Trunk Link Trunk Link


3
Frame
VLAN 100 W Z VLAN 200
2 (Port C)

Trunk Link
ISL Frame

1 Legend:
Trunk Links
Frame
Y VLAN 200
VLAN 200 VLAN 200 (Access Link)
(Port A) (Port B)

Port A and Port B on Switch Y have been defined as access links on the same VLAN. By def-
inition, they can belong to only VLAN 200 and cannot receive frames with a VLAN identi-
fier. As Switch Y receives traffic from Port A destined for Port B, Switch Y does not add an
ISL header to the frame.
Port C is also an access link that has been defined as a member of VLAN 200. If Port A sends
a frame destined for Port C, the switch does the following:
1. Switch Y receives the frame and identifies it as traffic destined for VLAN 200 by the
VLAN and port number association.
1439_CCNP_3.book Page 111 Wednesday, October 27, 2004 9:54 AM

VLAN Trunking and Dynamic Trunking Protocol 111

2. Switch Y encapsulates the frame with an ISL header identifying VLAN 200 and sends
the frame through the intermediate switch on a trunk link.
This process is repeated for every switch that the frame must transit as it moves to its
final destination of Port C.
3. Switch Z receives the frame, removes the ISL header, and forwards the frame to Port C.

VLAN Trunking and Dynamic Trunking Protocol


Layer 2 switching relies on trunk links between switches. Trunk ports can be configured to
autonegotiate trunk links via DTP, or trunk links can be hard-coded. This section explores
Ethernet trunks and DTP.

Trunking Overview
When a port is in trunk mode, the trunk link can be configured to transport all VLANs or a
restricted set of VLANs across an entire network. Trunk links are typically used to connect
switches to other switches, routers, or VLAN-enabled servers.
In basic terminology, a trunk is a point-to-point link that supports several VLANs. The pur-
pose of a trunk is to save ports when creating a link between two devices implementing
VLANs, as shown in Figure 2-24.

Figure 2-24 Trunk Links Carry Data Traffic for Multiple VLANs
VLAN 1 VLAN 1 VLAN 1
A
VLAN 2 Sa VLAN 2 Sb VLAN 2

VLAN 1 VLAN 1
Trunk
B
VLAN 2 Sa VLAN 1 and VLAN 2 Sb VLAN 2

In Portion A of Figure 2-24, two VLANs need to be available on two switches, Sa and Sb.
The first easy method of implementation is to create two physical links between the devices,
each one carrying the traffic for a separate VLAN.
Of course, this first solution does not scale very well. If the network has a third VLAN, you
would need to sacrifice two additional ports. This design is also inefficient in terms of load
sharing; the traffic on some VLANs might not justify a dedicated link. A trunk bundles virtual
links over one physical link.
In Portion B of Figure 2-24, one physical link between the two switches can carry traffic for
any VLAN. To achieve this, each frame sent on the link is tagged by Sa so that Sb knows
1439_CCNP_3.book Page 112 Wednesday, October 27, 2004 9:54 AM

112 Chapter 2: VLANs and VTP

which VLAN it belongs to. Different tagging schemes exist. The most common protocols for
Ethernet segments to follow are the IEEE 802.1Q standard and the Cisco-proprietary ISL
protocol.

Configuring a VLAN Trunk


To create or configure a VLAN trunk on a Cisco IOS-based switch, you must configure the
port as a trunk and specify the trunk encapsulation. To do this, issue the switchport mode
trunk and switchport trunk encapsulation [dot1q | isl] commands, as shown in
Example 2-15.

Example 2-15 Two Commands Generally Suffice to Configure an Interface for Trunking

Switch(config-if)#switchport mode trunk


Switch(config-if)#switchport trunk?
allowed Set allowed VLAN characteristics when
interface is in trunking mode
encapsulation Set trunking encapsulation when interface
is in trunking mode
native Set trunking native characteristics when
interface is in trunking mode
pruning Set pruning VLAN characteristics when
interface is in trunking mode

Switch(config-if)#switchport trunk encap ?


dot1q Interface uses only 801.1q trunking encapsulation
when trunking
isl Interface uses only ISL trunking encapsulation
when trunking

Switch(config-if)#switchport trunk encapsulation isl


Switch(config-if)#

dot1q trunk interfaces use only 802.1q trunking encapsulation when trunking. isl trunk inter-
faces use only ISL trunking encapsulation when trunking.
1439_CCNP_3.book Page 113 Wednesday, October 27, 2004 9:54 AM

VLAN Trunking and Dynamic Trunking Protocol 113

When configuring switches that allow multiple trunking encapsulations, dot1q or isl, the
switchport trunk encapsulation command must be used before the switchport mode trunk
command. By default, the switchport mode trunk command trunks all VLANs.
In 802.1Q trunking, all VLAN packets are tagged on the trunk link to indicate the VLAN to
which they belong. Frames belonging to the native VLAN are sent untagged on the trunk link.
The native VLAN contains ports not assigned to other VLANs that by default belong to
VLAN 1. VLAN 1 is the native VLAN by default, but VLANs other than VLAN 1 can be
designated as the native VLAN. However, the native VLAN must be the same on trunked
switches in 802.1Q trunking. If a VLAN other than VLAN 1 is to be the native VLAN, it
needs to be identified on the trunk ports. In the interface configuration mode of the trunk
port(s), the IOS-based command to designate the native VLAN is switchport trunk native
vlan vlan-id.
The switchport trunk native vlan command is necessary only when changing the native
VLAN from something other than VLAN 1 or when changing it back to VLAN 1.
Remember that the Catalyst 3550 switch supports both 802.1Q and ISL, whereas the Catalyst
2950 supports only 802.1Q.

Removing VLANs from a Trunk


By default, all VLANs are transported across a trunk link when you issue the trunk com-
mand. However, in some instances the trunk link should not carry all VLANs. One instance is
broadcast suppression. All broadcasts are sent to every port in a VLAN. A trunk link acts as a
member port of the VLAN and, therefore, must pass all the broadcasts. Bandwidth and pro-
cessing time are wasted if no port at the other end of the trunk link is a member of that VLAN.
Also, VLANs might also be removed from a trunk as a result of a topology change. Changes
that occur in the topology must also be propagated across the trunk link. If the VLAN is not
used on the other end of the trunk link, there is no need for the overhead of a topology
change.
By default, a Cisco IOS-based switch trunk port sends traffic to and receives traffic from all
VLANs in the VLAN database. All VLANs, 1 to 1005, are allowed on each trunk, but some
of those VLANs can be removed from the list of allowed VLANs, preventing traffic from
those VLANs from passing over the trunk. To restrict the traffic a trunk carries, use the
remove vlan-list parameter with the switchport trunk allowed vlan command.
1439_CCNP_3.book Page 114 Wednesday, October 27, 2004 9:54 AM

114 Chapter 2: VLANs and VTP

In Example 2-16, the switchport trunk allowed command is used to remove VLAN 3 and
then remove VLANs 6 to 10 from the trunk. This is verified by using the show running-
config command.

Example 2-16 Specifying the VLANs Allowed Over the Trunk Link

Switch(config-if)#switchport trunk allowed vlan remove 3


Switch(config-if)#switchport trunk allowed vlan remove 6-10
Switch#show running-config
<output omitted>
hostname Switch
!
ip subnet-zero
!
!
!
interface FastEthernet0/1
!
interface FastEthernet0/2
!
interface FastEthernet0/3
switchport trunk allowed vlan 1,2,4,5,11-1005
switchport mode trunk

To remove a large number of VLANs from a trunk link, it is often faster to clear all VLANs
from the trunk link before specifying the VLANs that are supposed to be on the link. The
command syntax is switchport trunk allowed vlan {add vlan-list | all | except vlan-list |
remove vlan-list}.

Basics of Dynamic Trunking Protocol


Ethernet trunk interfaces support several different trunking modes:
■ Access
■ Dynamic desirable (the default mode on Catalyst 2950 and 3550)
■ Dynamic auto
■ Trunk
■ Nonnegotiate
■ Dot1q-tunnel (not an option on the Catalyst 2950)
1439_CCNP_3.book Page 115 Wednesday, October 27, 2004 9:54 AM

VLAN Trunking and Dynamic Trunking Protocol 115

Using these different trunking modes, an interface can be set to trunking or nontrunking or
can be set to negotiate trunking with the neighboring interface. To automatically negotiate
trunking, the interfaces must be in the same VTP domain. Trunk negotiation is managed by
DTP, which is a Cisco-proprietary point-to-point protocol.
These various modes are configured using the switchport mode interface command, as
shown in Example 2-17. Table 2-4 shows the various DTP modes.

Example 2-17 Configuring Trunking Modes

3550-Switch(config-if)#switchport mode ?
access Set trunking mode to ACCESS unconditionally
dot1q-tunnel Set trunking mode to DOT1Q TUNNEL unconditionally
dynamic Set trunking mode to dynamically negotiate access or trunk mode
trunk Set trunking mode to TRUNK unconditionally

2950-Switch(config-if)#switchport mode ?
access Set trunking mode to ACCESS unconditionally
dynamic Set trunking mode to dynamically negotiate access or trunk mode
trunk Set trunking mode to TRUNK unconditionally

Table 2-4 DTP Modes

Command Description

switchport mode Puts the interface (access port) into permanent nontrunking
access mode. The interface generates DTP frames, negotiating with
the neighboring interface to convert the link into a nontrunk
link. The interface becomes a nontrunk interface even if the
neighboring interface does not agree to the change.

switchport mode Makes the interface actively attempt to convert the link into a
dynamic desirable trunk link. The interface becomes a trunk interface if the neigh-
boring interface is set to trunk, desirable, or auto mode. This
is the default mode for all Ethernet interfaces. If the neighbor-
ing interface is set to access or non-negotiate mode, the link
becomes nontrunking.

switchport mode Makes the interface willing to convert the link to a trunk link if
dynamic auto the neighboring interface is set to trunk or desirable mode.
Otherwise, the link becomes nontrunking.
continues
1439_CCNP_3.book Page 116 Wednesday, October 27, 2004 9:54 AM

116 Chapter 2: VLANs and VTP

Table 2-4 DTP Modes (Continued)

Command Description

switchport mode trunk Puts the interface into permanent trunking mode and negotiates
to convert the link into a trunk link. The interface becomes a
trunk interface even if the neighboring interface does not agree
to the change.

switchport nonegotiate Prevents the interface from generating DTP frames. You can
use this command only when the interface switchport mode is
access or trunk. You must manually configure the neighboring
interface as a trunk interface to establish a trunk link; other-
wise, the link is nontrunking.

DTP Trunk and Access Modes


Using the switchport mode interface command, two of the DTP modes set trunking to off or
on, as demonstrated in Example 2-18.

Example 2-18 Trunking Is Turned Off or On Based on the Switchport Mode

Switch(config-if)#switchport mode access


! Sets trunking OFF
Switch(config-if)#switchport mode trunk
! Sets trunking ON

Access Mode
In Example 2-19, Switch A and Switch B are connected on their FastEthernet 0/1 interfaces.
If both switches are set to access mode, the link is a nontrunking link. Both interfaces must be
on the same VLAN, and only that single VLAN is transmitted across the link.

Example 2-19 The switchport mode access Command Is Used for Access Links

SwitchA(config)#inter fa 0/1
SwitchA(config-if)#switchport mode access
SwitchB(config)#inter fa 0/1
SwitchB(config-if)#switchport mode access
1439_CCNP_3.book Page 117 Wednesday, October 27, 2004 9:54 AM

VLAN Trunking and Dynamic Trunking Protocol 117

Trunk Mode
If both switches are set to trunk mode, as shown in Example 2-20, the link is a trunking link. NOTE
By default, all VLANs are transmitted across this trunk. For switches such as the
Catalyst 3550 that are
capable of either
Example 2-20 The switchport mode trunk Command Is Used for Trunk Links
802.1Q or ISL trunking
encapsulation, the
SwitchA(config)#inter fa 0/1
switchport trunk
SwitchA(config-if)#switchport mode trunk encapsulation [dot1q |
SwitchB(config)#inter fa 0/1 isl | negotiate] interface
command must be used
SwitchB(config-if)#switchport mode trunk before the switchport
mode trunk command.

DTP Combinations
All the DTP modes and their various combinations can be somewhat confusing. Looking at
some of the basic combinations can help clarify this.

The Default: Desirable Mode


By default, Ethernet interfaces on most Cisco switches are set to desirable mode. This is
true for both the Catalyst 2950 and 3550 switches. Desirable mode creates a trunk link if the
neighboring interface is set to desirable, trunk, or auto mode. Because both interfaces by
default are in desirable mode, this means a link between two Cisco switches automatically
becomes a trunk link unless configured otherwise.

Combinations
Table 2-5 shows the various DTP trunking modes and the results of the different combinations.
One combination that could result in traffic being blocked from transmitting the link is if one
interface is in access mode and the neighboring interface is in trunk mode. In this case, the
access mode interface only wants to do nontrunking, whereas the trunk mode interface only
wants to do trunking. This is not a recommended combination and might create unexpected
results. Traffic might or might not be able to transit the link depending on several factors,
such as the spanning-tree root bridge location. In some situations, the link works as a non-
trunking link even though one interface is in access mode and the other interface is in trunk
mode. In other situations, spanning tree puts the access mode port into blocking mode and
traffic does not transit the link to the neighboring trunk mode interface. To get consistent
results, regardless of the topology, it is recommended that you never have a combination
of access mode and trunk mode on the interfaces of two neighboring switches.
118

Table 2-5 The DTP Trunking Modes Configured on Either End of a Link Determine the Link’s Operational Mode

Administrative Nonnegotiate Nonnegotiate


Mode Auto Desirable Trunk (On) Access (Off) (Access) (Trunk)
Chapter 2: VLANs and VTP

Auto Static access Trunk Trunk Static access Static access Unexpected
(NT) results
Desirable Trunk Trunk Trunk Static access Static access Unexpected
1439_CCNP_3.book Page 118 Wednesday, October 27, 2004 9:54 AM

results
Trunk (On) Trunk Trunk Trunk Unexpected Unexpected Trunk
results results
Access (Off) Static access Static access Unexpected Static access Static access Unexpected
results results
Nonnegotiate Static access Static access Unexpected Static access Static access Unexpected
(Access) results results

Nonnegotiate Unexpected Unexpected Trunk Unexpected Unexpected Trunk


(Trunk) results results results results
1439_CCNP_3.book Page 119 Wednesday, October 27, 2004 9:54 AM

VLAN Trunking and Dynamic Trunking Protocol 119

The only modes that actually negotiate trunking between adjacent switches are trunk,
dynamic desirable, and dynamic auto. Even though the switchport mode trunk command
does not modify its own interface to be anything other than trunking, it sends out DTP frames
to attempt to negotiate the other end of the link to be a trunking interface.
In Example 2-21, the show interface switchport command shows the negotiation of trunk-
ing set to on. The interface always attempts to negotiate trunking on the link unless the
switchport nonegotiate command is configured on the interface.

Example 2-21 Without the switchport nonegotiate Command, Trunking Negotiation Is Turned On

2950-1(config-if)#switchport mode dynamic auto


2950-1(config-if)#end
2950-1#show interface switchport
Name: Fa0/1
Switchport: Enabled
Administrative Mode: dynamic auto
Operational Mode: static access
Administrative Trunking Encapsulation: dot1q
Operational Trunking Encapsulation: native
Negotiation of Trunking: on
Access mode VLAN: 1 (default)
Trunking Native Mode VLAN: 1 (default)
Administrative private-vlan host-assocation: none
Administrative private-vlan mapping: none
Operational private-vlan: none
Trunking VLANs Enabled: ALL
Pruning VLANs Enabled: 2-1001

Nonegotiate
The switchport nonegotiate command prevents the interface from generating DTP frames,
turning off the negotiation of trunking. This can be viewed with the show interface switch-
port command. Example 2-22 shows the switchport nonegotiate interface command, which
can be used only on an interface that is in access or trunk mode, previously configured with
either the switchport mode access command or the switchport mode trunk command.
1439_CCNP_3.book Page 120 Wednesday, October 27, 2004 9:54 AM

120 Chapter 2: VLANs and VTP

Example 2-22 The switchport nonegotiate Command Prevents the Interface from Generating DTP Frames

2950-1(config-if)#switchport mode access


2950-1(config-if)#switchport mode nonegotiate
2950-1(config-if)#end

2950-1#show interface switchport


Name: Fa0/1
Switchport: Enabled
Administrative Mode: static access
Operational Mode: static access
Administrative Trunking Encapsulation: dot1q
Operational Trunking Encapsulation: native
Negotiation of Trunking: Off
Access mode VLAN: 1 (default)
Trunking Native Mode VLAN: 1 (default)
Administrative private-vlan host-assocation: none
Administrative private-vlan mapping: none
Operational private-vlan: none
Trunking VLANs Enabled: ALL
Pruning VLANs Enabled: 2-1001

If an interface is configured with both the switchport mode trunk command and the switch-
port nonegotiate command, the interface on the neighboring switch must be configured as
with the switchport mode trunk command to establish a trunk link. Otherwise, the link is a
nontrunking link.
To enable trunking to a device that does not support DTP, the switchport mode trunk and
switchport nonegotiate interface configuration commands should be used to cause the inter-
face to become a trunk but not to generate DTP frames. The switchport mode access and
switchport nonegotiate interface configuration commands should be used when configuring
a nontrunking interface to another switch that does not support DTP.

Verifying DTP
The show interface switchport command, shown in Example 2-23, can be used to verify the
following DTP information and status:
■ Administrative mode
■ Operational mode
■ Administrative trunking encapsulation
■ Negotiation of trunking
1439_CCNP_3.book Page 121 Wednesday, October 27, 2004 9:54 AM

VLAN Trunking and Dynamic Trunking Protocol 121

Example 2-23 The show interface switchport Command Is Extremely Useful for Verifying LAN Configuration

2950-1(config-if)#switchport mode dynamic auto


2950-1(config-if)#end
2950-1#show interface switchport
Name: Fa0/1
Switchport: Enabled
Administrative Mode: dynamic auto
Operational Mode: static access
Administrative Trunking Encapsulation: dot1q
Operational Trunking Encapsulation: native
Negotiation of Trunking: on
Access mode VLAN: 1 (default)
Trunking Native Mode VLAN: 1 (default)
Administrative private-vlan host-assocation: none
Administrative private-vlan mapping: none
Operational private-vlan: none
Trunking VLANs Enabled: ALL
Pruning VLANs Enabled: 2-1001

The Administrative Mode displays the interface’s DTP state. The default on most Cisco
switches is dynamic desirable. The DTP mode can be set using the switchport mode inter-
face command.
The Operational Mode shows whether the interface is in a trunking or nontrunking state. If
the Operational Mode is static access, this interface considers the link nontrunking. If the
operational mode is trunk, as shown in the output of the show interface switchport com-
mand in Example 2-24, this interface is considered a trunking link. The show interface trunk
command can be used to display all the interfaces on the switch that have the Operational
Mode set to trunk, as shown in Example 2-24.
The Administrative Trunking Encapsulation displays the trunking protocol, 802.1Q or ISL,
that is used on this interface if the operational mode is trunk. If the switch’s Operational
Mode is static access, nontrunking, the trunking protocol that Administrative Trunking
Encapsulation displays is not currently being used on the link.
The Negotiation of Trunking shows whether the interface is willing to negotiate trunking by
sending DTP frames. By default, the interface negotiates trunking and the Negotiation of
Trunking shows as on. Use the switchport nonegotiate interface command to turn off this
negotiation.
1439_CCNP_3.book Page 122 Wednesday, October 27, 2004 9:54 AM

122 Chapter 2: VLANs and VTP

Example 2-24 The show interface trunk Command Displays Useful Details About a Trunking Interface

2950-1#show interface switchport


Name: Fa0/1
Switchport: Enabled
Administrative Mode: dynamic desirable
Operational Mode: trunk
Administrative Trunking Encapsulation: dot1q
Operational Trunking Encapsulation: dot1q
Negotiation of Trunking: on
Access mode VLAN: 1 (default)
Trunking Native Mode VLAN: 1 (default)
Administrative private-vlan host-assocation: none
Administrative private-vlan mapping: none
Operational private-vlan: none
Trunking VLANs Enabled: ALL
Pruning VLANs Enabled: 2-1001

2950-1#show interface trunk

Port Mode Encapsulation Status Native vlan


Fa0/1 desirable 802.1q trunking 1

Port Vlans allowed on trunk


Fa0/1 1-4094

Port Vlans allowed and active in management domain


Fa0/1 1

Port Vlans in spanning tree forwarding


state and not pruned
Fa0/1 1

VLAN Identification
Although Ethernet VLAN frames are by far the most common type of tagged Layer 2 LAN
traffic, FDDI and Asynchronous Transfer Mode (ATM) also have their own tagging mecha-
nism for transporting traffic for multiple subnets over a single link. This section describes the
various tagging mechanisms used in LAN networks.
1439_CCNP_3.book Page 123 Wednesday, October 27, 2004 9:54 AM

VLAN Identification 123

VLAN Frame Identification


VLAN identification logically identifies which packets belong to which VLAN group. Multi-
ple trunking methods exist (as shown in Table 2-6):
■ ISL
■ IEEE 802.1Q
■ IEEE 802.10
■ ATM LAN Emulation (LANE)

Table 2-6 Different LAN Media Use Different VLAN Encapsulation Methods

Identification Tagging (Insertion


Method Encapsulation into Frame) Media

802.1Q No Yes Ethernet

ISL Yes No Ethernet

802.10 No No FDDI

LANE No No ATM

ISL is a Cisco-proprietary encapsulation protocol for trunking between switches. ISL


prepends a 26-byte header and appends a 4-byte cyclic redundancy check (CRC) to each
frame. ISL is supported in Cisco switches and routers.
The IEEE 802.1Q protocol is an IEEE standard method for identifying VLANs by inserting
a VLAN identifier into the frame header. This process is called frame tagging or internal
tagging.
The IEEE 802.10 standard is a method of transporting VLAN information inside the stan-
dard 802.10 frame (FDDI). The VLAN information is written to the Security Association
Identifier (SAID) portion of the 802.10 frame. This method is typically used to transport
VLANs across FDDI backbones.
LAN Emulation (LANE) is an ATM Forum standard that can be used to transport VLANs
over ATM networks, in which case they are called Emulated LANs (ELANs).

Inter-Switch Link (ISL)


ISL is a Cisco-proprietary protocol used to interconnect multiple switches and maintain
VLAN information as traffic travels between switches on trunk links. This technology pro-
vides one method for multiplexing bridge groups (VLANs) over a high-speed backbone. It is
1439_CCNP_3.book Page 124 Wednesday, October 27, 2004 9:54 AM

124 Chapter 2: VLANs and VTP

defined for Fast Ethernet and Gigabit Ethernet, as is IEEE 802.1Q. ISL has been available on
Cisco routers since Cisco IOS Release 11.1.
With ISL, an Ethernet frame is encapsulated with a header that transports VLAN IDs between
switches and routers, as shown in Figure 2-25.

Figure 2-25 The Cisco-Proprietary ISL Frame Format Has a 26-Byte Header

26-Byte ISL Header 4-Byte CRC

DA SA Ethernet/Length Data FCS

DA = Destination Address
SA = Source Address
FCS = Frame Check Sequence

ISL does add overhead to the packet as a 26-byte header containing a 10-bit VLAN ID. In
addition, a 4-byte CRC is appended to the end of each frame, as shown in Figure 2-26. This
CRC is in addition to any frame checking that the Ethernet frame requires.

Figure 2-26 The ISL Frame Format Includes a Field for the VLAN ID

40 4 4 48 16 24 24 15 1 16 16 Variable 32
Bits Bits Bits Bits Bits Bits Bits Bits Bit Bits Bits Length Bits

DA TYPE USER SA LEN SNAP/ HSA VLAN BPDU/ INDX Reserved Encapsulated FCS
LLC ID CDP Frame (CRC)

The fields in an ISL header identify the frame as belonging to a particular VLAN:
■ DA—A 40-bit multicast address with a value of 0x01-00-0C-00-00 that indicates to the
receiving Catalyst switch that the frame is an ISL encapsulated frame.
■ Type—A 4-bit value indicating the source frame type. Values include 0 0 0 0 (Ether-
net), 0 0 0 1 (Token Ring), 0 0 1 0 (FDDI), and 0 0 1 1 (ATM).
■ User—A 4-bit value usually set to 0. It can be used for special situations when trans-
porting Token Ring.
■ SA—The 802.3 MAC address of the transmitting Catalyst switch. This is a 48-bit
value.
■ Length—The LEN field is a 16-bit value indicating the length of the user data and ISL
header, excluding the DA, Type, User, SA, Length, and ISL CRC bytes.
■ SNAP—A 3-byte field with a fixed value of 0xAA-AA-03.
■ HSA—This 3-byte value duplicates the high-order bytes of the ISL SA field.
1439_CCNP_3.book Page 125 Wednesday, October 27, 2004 9:54 AM

VLAN Identification 125

■ VLAN—A 15-bit value to reflect the numerical value of the source VLAN that the user
frame belongs to. Note that only 10 bits are used.
■ BPDU—A single-bit value that, when set to 1, indicates that the receiving Catalyst
switch should immediately examine the frame at an end station because the data con-
tains either a spanning tree, ISL, VTP, or CDP message.
■ Index—Indicates what port the frame exited from the source Catalyst switch.
■ Reserved—Token Ring and FDDI frames have special values that need to be trans-
ported over the ISL link. These values, such as AC and FC, are carried in this field. The
value of this field is 0 for Ethernet frames.
■ User Frame—The original user data frame is inserted here, including the frame’s
frame check sequence (FCS).
■ CRC—ISL calculates a 32-bit CRC for the header and user frame. This double-checks
the message’s integrity as it crosses an ISL trunk. It does not replace the User Frame
CRC.
A VLAN ID is added only if the frame is forwarded out a port configured as a trunk link. If
the frame is to be forwarded out a port configured as an access link, the ISL encapsulation is
removed.

The IEEE 802.1Q Protocol


The official name of the IEEE 802.1Q protocol is the Standard for Virtual Bridged Local-
Area Networks. It relates to the capability to carry the traffic of more than one subnet down a
single cable. The IEEE 802.1Q committee defined this method of multiplexing VLANs in an
effort to provide multivendor VLAN support.
Both ISL and IEEE 802.1Q tagging perform explicit tagging, meaning that the frame is
tagged with VLAN information explicitly. However, whereas ISL uses an external tagging
process that does not modify the existing Ethernet frame, IEEE 802.1Q uses an internal tag-
ging process that does modify the Ethernet frame. This internal tagging process is what
allows IEEE 802.1Q tagging to work on both access and trunk links, because the frame
appears to be a standard Ethernet frame.
The IEEE 802.1Q frame-tagging scheme also has significantly less overhead than the ISL
tagging method. As opposed to the 30 bytes added by ISL, 802.1Q inserts only an additional
4 bytes into the Ethernet frame, as shown in Figure 2-27.

Figure 2-27 IEEE 802.1Q VLAN Encapsulation Is the Most Common Format Currently Used

Initial MAC 2-Byte TPID


Initial Type/Data New CRC
Address 2-Type TCI
1439_CCNP_3.book Page 126 Wednesday, October 27, 2004 9:54 AM

126 Chapter 2: VLANs and VTP

The IEEE 802.1Q header contains a 4-byte tag header that contains the following:
■ A 2-byte tag protocol identifier (TPID) with a fixed value of 0x8100 that indicates that
the frame carries the 802.1Q/802.1p tag information.
■ A 2-byte tag control information (TCI) that contains the following:
— 3-bit user priority
— 1-bit canonical format indicator (CFI)
— 12-bit VLAN identifier (VID) that uniquely identifies the VLAN to which the
frame belongs
The 802.1Q standard can create an interesting scenario on the network. Recalling that the
maximum size for an Ethernet frame as specified by IEEE 802.3 is 1518 bytes, this means
that if a maximum-sized Ethernet frame gets tagged, the frame size is 1522 bytes, a number
that violates the IEEE 802.3 standard. To resolve this issue, the 802.3 committee created a
subgroup called 802.3ac to extend the maximum Ethernet size to 1522 bytes. Network
devices that do not support a larger frame size process the frame successfully but might report
these anomalies as a “baby giant.”

The IEEE 802.10 Protocol


VLANs can be multiplexed across an FDDI backbone supporting the IEEE 802.10 protocol.
Catalyst 5000 and 6000 family switches support 802.10 trunking.
FDDI interfaces that support 802.10 make selective forwarding decisions within a network
domain based on a VLAN identifier. This VLAN identifier is the user-configurable 4-byte
IEEE 802.10 SAID. The SAID identifies traffic as belonging to a particular VLAN.
On a Catalyst 5000 or 6000, if an FDDI module receives a packet containing a VLAN SAID
that maps to a locally supported Ethernet VLAN on the switch, the FDDI module translates
the packet into Ethernet format and forwards it across the switch backplane to the Ethernet
module. FDDI modules filter the packets they receive from reaching the backplane if the
VLAN SAIDs in the packets do not map to a locally supported VLAN.
A SAID is applied when a frame from an Ethernet VLAN needs to cross an FDDI backbone,
as shown in Figure 2-28. Switch 1 must forward a packet from the Ethernet Module, Port 1,
Slot 2, to the FDDI Module, Port 1, Slot 5. In this example, the translation of Ethernet VLAN 2
to FDDI VLAN 22 must be specified. The VLAN SAID must be identical on both FDDI
modules. Because 802.10 FDDI interface links can also operate as ISL trunks, multiple
VLAN translations can take place over a single link.
1439_CCNP_3.book Page 127 Wednesday, October 27, 2004 9:54 AM

VLAN Identification 127

Figure 2-28 IEEE 802.10 Is the VLAN Encapsulation Method Used with FDDI
Ethernet Module FDDI Module
Slot 2 FDDI Module FDDI Module Slot 4
Port 1 Slot 5 Slot 3 Port 11
VLAN 2 Port 1 Port 1 VLAN 2
SAID 100002 VLAN 22 VLAN 22 SAID 100002
SAID 2 SAID 2
FDDI
Catalyst Switch 1 Catalyst Switch 2

FDDI modules also support one native (nontrunk) VLAN, which handles all non-802.10
encapsulated FDDI traffic.

LAN Emulation (LANE)


ATM LANE is a standard defined by the ATM Forum that gives two stations attached via
ATM the same capabilities they normally would have with legacy LANs, such as Ethernet
and Token Ring. As the name suggests, the function of the LANE protocol is to emulate a
LAN on top of an ATM network. Specifically, the LANE protocol defines mechanisms for
emulating either an IEEE 802.3 Ethernet or 802.5 Token Ring LAN.
The LANE protocol defines a service interface for network layer protocols that is identical to
that of existing LANs. Data sent across the ATM network is encapsulated in the appropriate
LAN MAC format. In other words, the LANE protocols make an ATM network look and
behave like an Ethernet or Token Ring LAN, albeit one operating much faster than standard
Ethernet or Token Ring LAN networks (see Figure 2-29).
An emulated LAN (ELAN) provides Layer 2 communication between all users on an ELAN.
One or more ELANs can run on the same ATM network. However, each ELAN is indepen-
dent of the others, and users on separate ELANs cannot communicate directly. As with a
VLAN, communication between ELANs is possible only through routers or bridges.
Because an ELAN provides Layer 2 communication, it can be equated to a broadcast domain.
VLANs can also be thought of as broadcast domains. This makes it possible to map an ELAN
to a VLAN on Layer 2 switches with different VLAN multiplexing technologies such as ISL
or 802.10. In addition, IP subnets and Internetwork Packet Exchange (IPX) networks that are
defined on Layer 3-capable devices such as routers frequently map into broadcast domains.
This makes it possible to assign an IP subnetwork or IP network to an ELAN.
1439_CCNP_3.book Page 128 Wednesday, October 27, 2004 9:54 AM

128 Chapter 2: VLANs and VTP

Figure 2-29 LANE Is the Mechanism Used by ATM for VLAN Encapsulation

LAN Emulation
LAN Emulation Catalyst Services
Client 6500
Layer 3 LECS, LES,
Services BUS

Enterprise and ATM-Attached


Department Servers Desktop

ATM Core
LAN
Emulation
Clients
Catalyst Catalyst Catalyst
6500 6500 6500

LAN Switches with ATM Uplinks

It is important to note that LANE does not attempt to emulate the access method of the spe-
cific LAN concerned (that is, carrier sense multiple access collision detect [CSMA/CD] for
Ethernet or token passing for IEEE 802.5). LANE requires no modifications to higher-layer
protocols to enable their operation over an ATM network. Because the LANE service pre-
sents the same service interface of existing MAC protocols to network layer drivers, such as
a network driver interface specification (NDIS) or Open Data-Link Interface (ODI) driver
interface, no changes are required for these drivers.

VLAN Trunking Protocol (VTP)


The role of VTP is to maintain VLAN configuration consistency across the entire network.
VTP is a messaging protocol that uses Layer 2 trunk frames to manage the addition, deletion,
and renaming of VLANs on a network-wide basis from a centralized switch that is in VTP
server mode. VTP is responsible for synchronizing VLAN information within a VTP domain.
This reduces the need to configure the same VLAN information on each switch.

VTP Benefits
VTP minimizes the possible configuration inconsistencies that arise when changes are made.
These inconsistencies can result in security violations, because VLANs can crossconnect
1439_CCNP_3.book Page 129 Wednesday, October 27, 2004 9:54 AM

VLAN Trunking Protocol (VTP) 129

when duplicate names are used. VLANs also could become internally disconnected when
they are mapped from one LAN type to another, such as Ethernet to ATM LANE ELANs or
FDDI 802.10 VLANs. VTP provides a mapping scheme that enables seamless trunking
within a network employing mixed-media technologies.
VTP provides the following benefits:
■ VLAN configuration consistency across the network
■ Mapping scheme that allows a VLAN to be trunked over mixed media
■ Accurate tracking and monitoring of VLANs
■ Dynamic reporting of added VLANs across the network
■ Plug-and-play configuration when adding new VLANs
As beneficial as VTP can be, it does have disadvantages that are normally related to STP. The
greatest risk is a bridging loop propagating throughout the entire campus network. Because
Cisco switches run an instance of STP for each VLAN, and because VTP propagates VLANs
across the campus LAN, VTP effectively creates more opportunities for a bridging loop to
occur. Network designers and administrators must balance the ease of administration made
possible by VTP with the risk of a large, potentially unstable STP domain.
Before you create VLANs on the switch that will be propagated via VTP, you must set up a
VTP domain. A VTP domain for a network is a set of all contiguously trunked switches with
the same VTP domain name. All switches in the same management domain share their VLAN
information with each other, and a switch can participate in only one VTP management
domain. Switches in different domains do not share VTP information.
Using VTP, each Catalyst family switch advertises the following on its trunk ports:
■ Management domain
■ Configuration revision number
■ Known VLANs and their specific parameters

VTP Operation
A VTP domain is made up of one or more interconnected devices that share the same VTP
domain name. A switch can be configured to be in one VTP domain only. Global VLAN
information is propagated across the network by way of connected switch trunk ports.
When VTP messages are transmitted to other switches in the network, the VTP message is
encapsulated in a trunking protocol frame such as ISL or IEEE 802.1Q, as shown in Figure 2-30.
1439_CCNP_3.book Page 130 Wednesday, October 27, 2004 9:54 AM

130 Chapter 2: VLANs and VTP

Figure 2-30 VTP Messages Are Encapsulated in ISL or IEEE 802.1Q Frames

Ethernet LLC SNAP VTP VTP


ISL Header CRC
Header Header Header Header Message

26 Bytes 14 Bytes 3 Bytes 3 Bytes

Varied Length

The VTP header varies, depending on the type of VTP message, but generally, four items are
found in all VTP messages:
■ VTP protocol version—Either version 1 or 2.
■ VTP message type—Indicates one of four types (summary advertisement, subset
advertisement, advertisement request, and/or join message).
■ Management domain name length—Indicates the size of the name that follows.
■ Management domain name—The name configured for the management domain.
It is important to note that switches can be configured not to accept VTP information. These
switches forward VTP information on trunk ports to ensure that other switches receive the
update, but the switches do not modify their database, nor do they send an update indicating a
change in VLAN status. This is called transparent mode.
By default, management domains are set to a nonsecure mode, meaning that the switches
interact without using a password. Adding a password automatically sets the management
domain to secure mode. A password must be configured on every switch in the management
domain to use secure mode.
Detecting the addition of VLANs within the advertisements notifies the switches that they
should be prepared to receive traffic on their trunk ports with the newly defined VLAN IDs,
emulated LAN names, or 802.10 SAIDs.
For example, in Figure 2-31, C6500-3 transmits a VTP database entry with additions or dele-
tions to C6500-1 and C6500-2. The configuration database has a revision number that is noti-
fication +1. A higher configuration revision number indicates that the VLAN information that
is being sent is more current than the stored copy. Any time a switch receives an update that
has a higher configuration revision number, the switch overwrites the stored information with
the new information being sent in the VTP update.
1439_CCNP_3.book Page 131 Wednesday, October 27, 2004 9:54 AM

VLAN Trunking Protocol (VTP) 131

Figure 2-31 The VTP Configuration Revision Number Iterates When VLAN Information Is Changed
on a VTP Server

N+1

C6500-3 C6500-6

BCMSN CE_
Domain Domain

3/1 3/2 4/1 4/2


N+1 N+1

1/1 2/2 5/1 1/1

1/2 2/1
C6500-1 C6500-2 C6500-4 C6500-5

To use VTP, a VTP domain name must be assigned to each switch. VTP domain names are
case-sensitive. VTP information remains in the VLAN management domain. The following
are conditions for a VTP domain:
■ Each Catalyst switch in a domain must have the same VTP domain name, whether
learned or configured.
■ The Catalyst switches must be adjacent, meaning that all switches in the VTP domain
form a contiguous tree in which every switch is connected to every other switch in the
domain via the tree.
■ Trunking must be enabled between all Catalyst switches.
If any one of these conditions is not met, the VTP domain becomes disconnected, and infor-
mation does not travel between the separate parts of the network.

VTP Modes
Switches can operate in any one of the following three VTP modes, as described in Table 2-7
and the following sections:
■ Server
■ Client
■ Transparent
1439_CCNP_3.book Page 132 Wednesday, October 27, 2004 9:54 AM

132 Chapter 2: VLANs and VTP

Table 2-7 VTP Mode Characteristics

Feature Server Client Transparent

Source VTP messages Yes Yes No

Listen to VTP messages Yes Yes No

Create VLANs Yes No Yes*

Remember VLANs Yes No Yes*


* Locally significant only

VTP Server Mode


By default, a Catalyst switch is in VTP server mode and in the “no management domain”
state until the switch receives an advertisement for a domain over a trunk link or a VLAN
management domain is configured. A switch that has been put in VTP server mode and that
has a domain name specified can create, modify, and delete VLANs. VTP servers can also
specify other configuration parameters, such as VTP version and VTP pruning for the entire
VTP domain. VTP information is stored in nonvolatile RAM (NVRAM).
VTP servers advertise their VLAN configuration to other switches in the same VTP domain
and synchronize the VLAN configuration with other switches based on advertisements
received over trunk links. When a change is made to the VLAN configuration on a VTP
server, it is propagated to all switches in the VTP domain. VTP advertisements are transmit-
ted out all trunk connections, including ISL, IEEE 802.1Q, IEEE 802.10, and ATM LANE
trunks.
A critical parameter governing VTP function is the VTP configuration revision number.
This 32-bit number indicates the particular revision of a VTP configuration. A configuration
revision number starts at 0 and increments by 1 with each modification until it reaches
4294927295, at which point it cycles back to 0 and starts incrementing again. Each VTP
device tracks its own VTP configuration revision number; VTP packets contain the sender’s
VTP configuration number. This information determines whether the received information is
more recent than the current version. To reset a configuration revision number to 0, simply
disable trunking, change the VTP domain name, change it back to the original name, and
reenable trunking.
If the switch receives a VTP advertisement over a trunk link, it inherits the VTP domain name
and configuration revision number. The switch ignores advertisements that have a different
VTP domain name or an earlier configuration revision number.
1439_CCNP_3.book Page 133 Wednesday, October 27, 2004 9:54 AM

VLAN Trunking Protocol (VTP) 133

VTP Client Mode


The VTP client maintains a full list of all VLANs within the VTP domain, but it does not
store the information in NVRAM. VTP clients behave the same way as VTP servers, but it is
not possible to create, change, or delete VLANs on a VTP client. Any changes made must be
received from a VTP server advertisement.

VTP Transparent Mode


VTP transparent switches do not participate in VTP. A VTP transparent switch does not
advertise its VLAN configuration and does not synchronize its VLAN configuration based on
received advertisements. However, in VTP version 2, transparent switches do forward VTP
advertisements that the switches receive out their trunk ports. VLANs can be configured on a
switch in VTP transparent mode, but the information is local to the switch (VLAN informa-
tion is not propagated to other switches) and is stored in NVRAM.
There is also an “off” VTP mode in which switches behave the same as in VTP transparent
mode, except that VTP advertisements are not forwarded.

Adding a Switch to a VTP Domain


Use caution when inserting a new switch into an existing domain. To prepare a switch to enter
an existing VTP domain, follow these steps:
Step 1 Delete the VLAN database, erase the startup configuration, and power-cycle
the switch. This avoids potential problems resulting from residual VLAN con-
figurations or from adding a switch with a higher VTP configuration revision
number that could result in the propagation of incorrect VLAN information.
From privileged mode, issue the delete vlan.dat and erase startup-config
commands, and then power-cycle the switch.
Step 2 Determine the switch’s VTP mode of operation and include it when setting the
VTP domain name information on the switch. If you leave the switch in server
mode, be sure to verify that the configuration revision number is set to 0 before
adding the switch to the VTP domain. It is generally recommended that you
have several servers in the domain, with all other switches set to client mode
for the purposes of controlling VTP information.
Step 3 It is also highly recommended that you use secure mode in your VTP domain.
Assigning a password to the domain accomplishes this. It prevents unautho-
rized switches from participating in the VTP domain. From privileged mode or
VLAN configuration mode, use the vtp password password command.
1439_CCNP_3.book Page 134 Wednesday, October 27, 2004 9:54 AM

134 Chapter 2: VLANs and VTP

VTP Advertisements
Periodic VTP advertisements are sent out each trunk port with the multicast destination MAC
address 01-00-0C-CC-CC-CC. VTP advertisements contain the following configuration
information:
■ VLAN IDs (ISL and 802.1Q)
■ Emulated LAN names (ATM LANE)
■ 802.10 SAID values (FDDI)
■ VTP domain name
■ VTP configuration revision number
■ VLAN configuration, including the maximum transmission unit (MTU) size for each
VLAN
■ Frame format
VTP messages are encapsulated in either ISL frames or IEEE 802.1Q frames.
VTP messages are sent with the following Ethernet frame field values:
■ Multicast destination MAC address 01-00-0C-CC-CC-CC
■ Destination Service Access Point (DSAP) 0xAA in the Logical Link Control (LLC)
header
■ Source Service Access Point (SSAP) 0xAA in the LLC header
■ Organizational Unique Identifier (OUI) of 00-00-0C (for Cisco) in the Subnetwork
Access Protocol (SNAP) header
■ Ethertype of 2003 in the SNAP header
VTP packets can be encapsulated into an ISL frame. The VTP header’s format varies,
depending on the type of VTP message. However, all packets contain the following fields in
the header:
■ VTP protocol version—1 or 2
■ VTP message type
■ Management domain length
■ Management domain name
VTP uses the following message types:
■ Summary advertisements
■ Subset advertisements
■ Advertisement requests
■ VTP join messages
1439_CCNP_3.book Page 135 Wednesday, October 27, 2004 9:54 AM

VLAN Trunking Protocol (VTP) 135

VTP join messages, which rely on the VTP pruning protocol, are examined in the “VTP Con-
figuration and VTP Pruning” section.
Advertisements on factory-default VLANs are based on media types. User ports should not
be configured as VTP trunks.
There are two types of advertisements:
■ Requests from clients that want information at bootup
■ Response from servers
Figure 2-32 illustrates advertisement requests, summary advertisements, and subset
advertisements.

Figure 2-32 Advertisement Requests, Summary Advertisements, and Subset Advertisements Are
Used with VTP Operation

Advertisement Request
1 2 3 4
Version Code Rsvd MgmtD Len
Management Domain Name (Zero-Padded to 32 Bytes)
Start Value

Summary Advertisement
1 2 3 4
Version Code Followers MgmtD Len
Management Domain Name (Zero-Padded to 32 Bytes)
Configuration Revision Number
Updater Identity
Update Timestamp (12 Bytes)
MD5 Digest (16 Bytes)

Subset Advertisement
1 2 3 4
Version Code Seq-Num MgmtD Len
Management Domain Name (Zero-Padded to 32 Bytes)
Configuration Revision Number
VLAN-Info Field 1
Updater Identity
Update Timestamp (12 Bytes)
VLAN-Info Field N

Advertisement Requests
A switch issues a VTP advertisement request in the following situations:
■ The switch has been reset.
■ The VTP domain name has been changed.
■ The switch has received a VTP summary advertisement with a higher configuration
revision number than its own.
1439_CCNP_3.book Page 136 Wednesday, October 27, 2004 9:54 AM

136 Chapter 2: VLANs and VTP

The server responds with summary and subset advertisements (refer to Figure 2-32):
■ Code is 0x03 for advertisement request (type 3).
■ Rsvd is reserved and always set to 0.
■ Start-Value is used in cases in which there are several subset advertisements. If subset
advertisements n is the first advertisement that has not been received in a sequence of
advertisements, an advertisement request is sent for advertisements starting with n. If
the start value is 0, all subset advertisements are sent for the particular management
domain.

Summary Advertisements
By default, Catalyst switches issue summary advertisements every 5 minutes. They inform
neighbor switches of the current domain name and the configuration revision number.
When the switch receives a summary advertisement packet, as shown in Figure 2-33, it com-
pares the VTP domain name. If the name is different, the switch simply ignores the packet. If
the name is the same, the switch then compares the configuration revision. If its own configu-
ration revision is higher or equal, the packet is ignored. If it is lower, an advertisement request
is sent.

Figure 2-33 Summary Advertisements Include the VTP Domain Name and the Configuration
Revision Number

Number of Subset Domain Name


Version Code
Advertisement Messages Length

Management Domain Name (Zero-Padded to 32 Bytes)


Configuration Revision Number
Updater Identity
Update Timestamp (12 Bytes)
MD5 Digest (16 Bytes)

The fields illustrated in Figure 2-33 are defined as follows:


■ Version indicates the VTP version, which is either 1 or 2.
■ Code indicates which of the four VTP message types is included. Here, 0x01 or type 1
indicates summary advertisements.
■ Number of Subset Advertisement Messages (type 2) follows the Code field. The value
can range from 0 to 255; 0 indicates that no subset advertisements follow. A Catalyst
transmits the subset advertisement only if there is a change in the system or as a
response to an advertisement request.
1439_CCNP_3.book Page 137 Wednesday, October 27, 2004 9:54 AM

VLAN Trunking Protocol (VTP) 137

■ Domain Name Length specifies the length of the VTP domain name.
■ Management Domain Name specifies the VTP domain name.
■ The Configuration Revision Number field is 32 bytes.
■ The Updater Identity is the IP address of the last switch that incremented the configura-
tion revision.
■ Update Timestamp is the date and time of the last increment of the configuration
revision.
■ MD5 Digest consists of a message-digest hash—a function of the VTP password and
the VTP header contents (excluding the MD5 Digest field). If the receiving Catalyst
hash computation does not match, the packet is discarded.

Subset Advertisements
When a VLAN is added, changed, or deleted on a VTP server, the configuration revision num-
ber is incremented, and a summary advertisement is issued, followed by one or several subset
advertisements. Subset advertisements are also triggered by suspending or activating a VLAN,
changing its name, or changing the MTU. A subset advertisement contains a list of VLANs
and corresponding VLAN information. If there are several VLANs, as shown in Figure 2-34,
more than one subset advertisement might be required to advertise all the information.

Figure 2-34 Multiple VLANs Might Require Several VTP Subset Advertisements

Version Code Seq-Number Domain Name Length


Management Domain Name (Zero-Padded to 32 Bytes)
Configuration Revision Number
VLAN-info Field 1
..
VLAN-info Field N

The VLAN-info Field Contains Information for Each VLAN and Is Formatted as Follows:
Info Length Status VLAN-Type VLAN-Name Len
ISL VLAN-ID MTU Size
802.10 Index
VLAN-Name (Padded with Zeros to Multiple of 4 Bytes)

The fields in a VTP subset advertisement are as follows:


■ Code is 0x02 for subset advertisement (type 2).
■ Seq-Number represents the packet’s sequence number in the stream of subset advertise-
ments following a summary advertisement. The sequence starts with 1. The receiving
Catalyst uses this value to ensure that it receives all subset advertisements. If it does not
receive all the subsets, it requests a resend, starting with a specific subset advertisement.
1439_CCNP_3.book Page 138 Wednesday, October 27, 2004 9:54 AM

138 Chapter 2: VLANs and VTP

VLAN-info fields each contain the following information:


■ The VLAN’s status (active or suspended)
■ VLAN-Type (Ethernet, Token Ring, FDDI, or otherwise)
■ VLAN-Name Len—Length of the VLAN name
■ ISL VLAN-ID—VLAN number of this named VLAN
■ MTU size—Maximum frame size supported for this VLAN
■ 802.10 Index—SAID value used if the frame passed over an FDDI trunk
■ VLAN-name
The VTP subset advertisement lists this information for each individual VLAN, including
default VLANs.

VTP Configuration and VTP Pruning

Basic Configuration Steps


The following basic tasks should be carried out before implementing VTP on a network:
Step 1 Determine the version number of VTP that will be running.
Step 2 Decide if this switch is to be a member of an existing management domain or
if a new domain should be created. If a management domain does exist, deter-
mine the domain’s name and password.
Step 3 Choose a VTP mode for the switch.
Remember too that for VTP to function, ports designated as trunk links also need to be
configured.

VTP Configuration Options


VTP can be configured using the following configuration modes:
■ Global configuration mode.
■ VLAN configuration mode. VLAN configuration mode is accessed by entering the
vlan database privileged EXEC command.
Example 2-25 demonstrates VTP configuration in global configuration mode.
1439_CCNP_3.book Page 139 Wednesday, October 27, 2004 9:54 AM

VTP Configuration and VTP Pruning 139

Example 2-25 VTP Configuration in Global Configuration Mode NOTE

Switch#config terminal The exit or end com-


mand can be used to
Switch(config)#vtp version 2 leave VLAN global
Switch(config)#vtp mode server configuration mode.
The exit command
Switch(config)#vtp domain cisco must be used to leave
Switch(config)#vtp password mypassword VLAN database config-
uration mode.
Switch(config)#end

Example 2-26 illustrates VTP configuration in VLAN database configuration mode.

Example 2-26 VTP Configuration in VLAN Database Configuration Mode

Switch#vlan database
Switch(vlan)#vtp v2-mode
Switch(vlan)#vtp server
Switch(vlan)#vtp domain cisco
Switch(vlan)#vtp password mypassword
Switch(vlan)#exit

Lab 2.9.2 Catalyst 2950T and 3550 Series VTP Domain and VLAN Trunking
In this lab exercise, you configure a VLAN trunk between two Cisco Catalyst
WS-C2950T-24-EI switches and a Cisco Catalyst WS-C3550-24-EMI switch in
CLI mode.

Configuring the VTP Version


Two different versions of VTP can run in the management domain: VTP version 1 and VTP
version 2. The two versions are not interoperable in the same VTP domain. The major differ-
ence between the two versions is that version 2 introduces support for Token Ring VLANs.
If all switches in a VTP domain can run VTP version 2, version 2 needs to be enabled on only
one VTP server switch. The version number is propagated to the other VTP version 2-capable
switches in the VTP domain. Version 2 should not be enabled unless every switch in the VTP
domain supports version 2.
The VTP version can be configured from global configuration mode or VLAN database mode
on a Cisco IOS-based switch. From there, the VTP version can be changed with the vtp
command.
1439_CCNP_3.book Page 140 Wednesday, October 27, 2004 9:54 AM

140 Chapter 2: VLANs and VTP

Example 2-27 specifies the VTP version in global configuration mode.

Example 2-27 Specifying the VTP Version in Global Configuration Mode

Switch#config terminal
Switch(config)#vtp version 2

Example 2-28 specifies the VTP version in VLAN database configuration mode.

Example 2-28 Specifying the VTP Version in VLAN Database Configuration Mode

Switch#vlan database
Switch(vlan)#vtp v2-mode

Configuring the VTP Domain


If the switch being installed is the first switch in the network, the management domain needs
to be created. However, if the network has other switches running VTP, the new switch joins
an existing management domain. Verify the name of the management domain. If the manage-
ment domain has been secured, verify and configure its password.
To create a management domain or to add a switch to a management domain, use the vtp
domain command in global configuration mode or VLAN configuration mode.
If a VTP password is in use, it needs to be configured on all switches in the domain. The VTP
password is translated using an algorithm resulting in a 16-byte MD5 value carried in all
summary advertisements. From privileged mode or VLAN configuration mode, use the vtp
password command. To remove the password, use the no vtp password command.
The domain name can be up to 32 characters, and the password must be between 8 and
64 characters.
Example 2-29 configures the VTP domain and password in global configuration mode.

Example 2-29 Specifying the VTP Domain and Password in Global Configuration Mode

Switch#config terminal
Switch(config)#vtp domain cisco
Switch(config)#vtp password mypassword
1439_CCNP_3.book Page 141 Wednesday, October 27, 2004 9:54 AM

VTP Configuration and VTP Pruning 141

Example 2-30 demonstrates that the VTP domain and password can also be configured in
VLAN database configuration mode.

Example 2-30 Specifying the VTP Domain and Password in VLAN Database Configuration Mode

Switch#vlan database
Switch(vlan)#vtp domain cisco
Switch(vlan)#vtp password mypassword

Configuring the VTP Mode


Here are some general guidelines for choosing a switch’s VTP mode:
■ If this is the first switch in the management domain and additional switches will be
added, set the mode to server.
■ If there are any other switches in the management domain, set the switch mode to client
to prevent the new switch from accidentally propagating the incorrect information to
your existing network.
■ If a new switch needs to be set up as a VTP server, change the switch’s mode to server
after it has learned the correct VLAN information from the network while in client
mode.
■ If the switch won’t share VLAN information with any other switch on the network, set
it to transparent mode.
To set the correct mode of a Cisco IOS-based switch in global configuration mode, use the
vtp mode command, as demonstrated in Example 2-31.

Example 2-31 Specifying the VTP Mode in Global Configuration Mode

Switch#config terminal
Switch(config)#vtp mode [client | server | transparent]

To set the correct mode of a Cisco IOS-based switch in VLAN database configuration mode,
use the vtp command, as demonstrated in Example 2-32.

Example 2-32 Specifying the VTP Mode in VLAN Database Configuration Mode

Switch#vlan database
Switch(vlan)#vtp [client | server | transparent]
1439_CCNP_3.book Page 142 Wednesday, October 27, 2004 9:54 AM

142 Chapter 2: VLANs and VTP

Verifying VTP Configuration


The show vtp status command, shown in Example 2-33, is used to verify VTP configuration
settings on a Cisco IOS-based switch.

Example 2-33 The show vtp status Command Displays Important VTP Information

Elmhurst#show vtp status


VTP Version : 2
Configuration Revision : 0
Maximum VLANs supported locally : 250
Number of existing VLANs : 9
VTP Operating Mode : Transparent
VTP Domain Name : CIT
VTP Pruning Mode : Enabled
VTP V2 Mode : Disabled
VTP Traps Generation : Disabled
MD5 digest : 0x61 0xEB 0x7B 0x1E 0xX4 0x2D 0x24 0x58
Configuration last modified by 0.0.0.0 at 3-1-93 00:02:53

The show vtp counters command, shown in Example 2-34, can also be used to verify VTP
advertisement messages sent and received, as well as configuration errors detected. This com-
mand is useful when troubleshooting VTP.

Example 2-34 The show vtp counters Command Displays the Number of VTP Advertisement Requests, Summary
Advertisements, Subset Advertisements, and Join Messages Sent and Received

Elmhurst#show vtp counters


VTP statistics:
Summary advertisements received : 0
Subset advertisements received : 0
Request advertiements received : 0
Summary advertisements transmitted : 0
Subset advertisements transmitted : 0
Request advertiements transmitted : 0
Number of config revision errors : 0
Number of config digest errors : 0
Number of V1 summary errors : 0
1439_CCNP_3.book Page 143 Wednesday, October 27, 2004 9:54 AM

VTP Configuration and VTP Pruning 143

Example 2-34 The show vtp counters Command Displays the Number of VTP Advertisement Requests, Summary
Advertisements, Subset Advertisements, and Join Messages Sent and Received (Continued)

VTP pruning statisitcs:

Trunk Join Transmitted Join Received Summary advts received from


non-pruning-capable device
---------------- ---------------- --------------- --------------------------
Fa0/2 0 0 0
Po6 0 0 0

Default Behavior of a Switch


A switch’s default behavior is to propagate broadcast and unknown packets across the net-
work. This behavior results in a large amount of unnecessary traffic crossing the network.
VTP pruning increases bandwidth efficiency by reducing unnecessary flooding of traffic,
such as broadcast, multicast, unknown, and flooded unicast packets. VTP pruning increases
available bandwidth by restricting flooded traffic to those trunk links that the traffic must use
to access the appropriate network devices. By default, VTP pruning is disabled.
In a switched network that does not have VTP pruning enabled, broadcasts are sent to
switches that do not need to receive them. In Figure 2-35, Port 1 on Switch 1 and Port 2 on
Switch 4 are assigned to VLAN 10. A broadcast is sent from the host connected to Switch 1.

Figure 2-35 Ethernet Frames Are Propagated According to How VTP Pruning Is Configured

C6500-4 VLAN 10

Port 2

Port 4

C6500-5 C6500-2

Port 5

Port 1

C6500-6 C6500-3 C6500-1 VLAN 10

Switch C6500-1 floods the broadcast. Every switch in the network receives this broadcast,
even though Switches C6500-3, C6500-5, and C6500-6 have no ports in VLAN 10.
1439_CCNP_3.book Page 144 Wednesday, October 27, 2004 9:54 AM

144 Chapter 2: VLANs and VTP

With VTP pruning enabled, the broadcast traffic from Switch C6500-1 is not forwarded to
Switches C6500-3, C6500-5, and C6500-6 because traffic for VLAN 10 has been pruned on
Port 5 on Switch C6500-2 and Port 4 on Switch C6500-4.

Configuring VTP Pruning


Enabling VTP pruning on a VTP server enables pruning for the entire management domain.
VTP pruning takes effect several seconds after it is enabled. By default, VLANs 2 to 1000 or
2 to 1001 are pruning-eligible, depending on the platform. VTP pruning does not prune traffic
from VLANs that are pruning-ineligible. VLAN 1 is always pruning-ineligible, and it cannot be
removed from a trunk. However, the “VLAN 1 disable on trunk” feature available on Catalyst
4000, 5000, and 6000 family switches enables the pruning of user traffic, but not protocol traf-
fic, such as CDP and VTP, for VLAN 1 from a trunk. Use the vtp pruning VLAN database
configuration command to make VLANs pruning-eligible on a Cisco IOS-based switch.
As soon as pruning is enabled, use the switchport trunk pruning interface configuration
command to make a specific VLAN pruning-ineligible. Example 2-35 shows how to enable
pruning for all VLANs except VLANs 5 to 10 (VLANs 5 to 10 are pruning-ineligible).

Example 2-35 VTP Pruning Is Enabled on a VTP Server. The Specific VLANs That Are Pruned Can Be Configured
on an Interface

Switch(vlan)#vtp pruning
Pruning switched ON
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z
Switch(config)#interface fastethernet 0/3
Switch(config-if)#switchport trunk pruning vlan remove 5-10
Switch(config-if)#

Lab 2.9.3 Catalyst 2950T and 3550 Series VTP Pruning


In this lab exercise, you configure VTP pruning between two Cisco Catalyst
WS-C2950T-24-EI switches and a Cisco Catalyst WS-C3550-24-EMI switch using
CLI mode.
1439_CCNP_3.book Page 145 Wednesday, October 27, 2004 9:54 AM

VTP Configuration and VTP Pruning 145

Verifying VTP Pruning


To verify the VLANs that are either pruned or not pruned on a Cisco IOS-based switch, use
either the show running-config or show interface interface-id switchport command, as
shown in Example 2-36.

Example 2-36 Verifying VTP Pruning

Switch#show running-config

<output omitted>

hostname Switch
!
ip subnet-zero
!
!
!
interface FastEthernet0/1
!
interface FastEthernet0/2
!
interface FastEthernet0/3
switchport trunk allowed vlan 1,2,4,5,11-1005
switchport trunk pruning vlan 2-4, 11-1001
switchport mode trunk
!
interface FastEthernet0/4
Switch#show interface fastethernet 0/3 switchport
Name: Fa0/2
Switchport: Enabled
Administrative mode: trunk
Operational Mode: trunk
Administrative Trunking Encapsulation: isl
Operational Trunking Encapsulation: isl
Negotiation of Trunking: Disabled

continues
1439_CCNP_3.book Page 146 Wednesday, October 27, 2004 9:54 AM

146 Chapter 2: VLANs and VTP

Example 2-36 Verifying VTP Pruning (Continued)

Access Mode VLAN: 0 ((Inactive))


Trunking Native Mode VLAN: 1 (default)
Trunking VLANs Enabled: 1,2,4,5,11-1005
Trunking VLANs Active: 1,2
Pruning VLANs Enabled: 2-4,11-1001

Priority for untagged frames: 0


Override vlan tag priority: FALSE
Voice VLAN: none
Appliance trust: none
Switch#

The show vtp counters and debug sw-vlan vtp pruning commands can also be useful for
verifying VTP pruning.

Summary
The following concepts were covered in this chapter:
■ VLANs solve many of the issues found in Layer 2 environments, including broadcast
control, isolation of problem components in the network, security, and load balancing
through the use of a Layer 3 protocol between VLANs.
■ VLAN identification allows different VLANs to be carried on the same physical link,
called a trunk link. Four major trunking technologies exist: ISL, IEEE 802.1Q, IEEE
802.10, and ATM LANE. ISL encapsulates Ethernet frames, and IEEE 802.1Q embeds
a tag in the Ethernet header.
■ The VLAN Trunking Protocol (VTP) provides support for dynamic reporting of the
addition, deletion, and renaming of VLANs across the switch fabric.
■ VTP pruning permits the dynamic pruning of unnecessary VLAN traffic within the
management domain.
1439_CCNP_3.book Page 147 Wednesday, October 27, 2004 9:54 AM

Key Terms 147

Key Terms
access port A switch port that connects to an end-user device or a server.
ATM LAN Emulation (ATM LANE) A standard defined by the ATM Forum that gives two
stations attached via ATM the same capabilities they normally have with Ethernet and Token
Ring.
clustering A method of managing a group of switches without having to assign an IP
address to every switch.
Dynamic Trunking Protocol (DTP) A Cisco-proprietary protocol that autonegotiates trunk
formation for either ISL or 802.1Q trunks.
Dynamic VLAN A VLAN in which end stations are automatically assigned to the appropri-
ate VLAN based on their MAC address. This is made possible via a MAC address-to-VLAN
mapping table contained in a VLAN Management Policy Server (VMPS) database.
Emulated LAN (ELAN) A logical construct, implemented with switches, that provides
Layer 2 communication between a set of hosts in a LANE network. See ATM LAN Emulation
(ATM LANE).
end-to-end VLAN Also known as a campus-wide VLAN. An end-to-end VLAN spans a
campus network. It is characterized by the mapping to a group of users carrying out a similar
job function (independent of physical location).
IEEE 802.10 The IEEE standard that provides a method for transporting VLAN informa-
tion inside the IEEE 802.10 frame (FDDI). The VLAN information is written to the security
association identifier (SAID) portion of the 802.10 frame. This allows for transporting
VLANs across FDDI backbones.
IEEE 802.1Q The IEEE standard for identifying VLANs associated with Ethernet frames.
IEEE 802.1Q trunking works by inserting a VLAN identifier into the Ethernet frame header.
Inter-Switch Link (ISL) A Cisco-proprietary encapsulation protocol for creating trunks.
ISL prepends a 26-byte header and appends a 4-byte CRC to each data frame.
LAN Emulation (LANE) An ATM Forum standard used to transport VLANs over ATM
networks.
local VLAN Also known as a geographic VLAN. A local VLAN is defined by a restricted
geographic location, such as a wiring closet.
native VLAN The VLAN that a trunk port reverts to if trunking is disabled on the port.
port-based VLAN Also known as a static VLAN. A port-based VLAN is configured manu-
ally on a switch, where ports are mapped, one by one, to the configured VLAN. This hard-
codes the mapping between ports and VLANs directly on each switch.
1439_CCNP_3.book Page 148 Wednesday, October 27, 2004 9:54 AM

148 Chapter 2: VLANs and VTP

private VLAN A VLAN you configure to have some Layer 2 isolation from other ports
within the same private VLAN. Ports belonging to a private VLAN are associated with a
common set of supporting VLANs that create the private VLAN structure.
trunk A point-to-point link connecting a switch to another switch, router, or server. A trunk
carries traffic for multiple VLANs over the same link. The VLANs are multiplexed over the
link with a trunking protocol.
virtual LAN (VLAN) A group of end stations with a common set of requirements, indepen-
dent of their physical location, that communicate as if they were attached to the same wire. A
VLAN has the same attributes as a physical LAN but allows you to group end stations even if
they are not located physically on the same LAN segment.
VLAN Management Policy Server (VMPS) A Cisco-proprietary solution for enabling
dynamic VLAN assignments to switch ports within a VTP domain.
VLAN map Referred to as a VLAN access control list (VACL) in the context of Catalyst
6500 switches. A generalized access control list applied on a Catalyst switch that permits fil-
tering of both intra-VLAN and inter-VLAN packets.
VLAN Trunking Protocol (VTP) A Cisco-proprietary protocol used to communicate infor-
mation about VLANs between Catalyst switches.
VTP domain Also called a VLAN management domain. A network’s VTP domain is the set
of all contiguously trunked switches with the same VTP domain name.
VTP pruning A switch feature used to dynamically eliminate, or prune, unnecessary
VLAN traffic.

Check Your Understanding


Use the following review questions to test your understanding of the concepts covered in this
chapter. Answers are listed in Appendix A, “Check Your Understanding Answer Key.”
1. For which of the following VTP modes does a Catalyst switch listen to VTP
advertisements?
A. Client

B. Server

C. Transparent

D. Peer
1439_CCNP_3.book Page 149 Wednesday, October 27, 2004 9:54 AM

Check Your Understanding 149

2. Which of the following are Cisco-proprietary protocols?

A. CDP

B. VQP

C. VTP

D. ISL
3. Which of the following are VLAN trunking methods?

A. ATM LANE

B. IEEE 802.10

C. IEEE 802.1Q

D. ISL
4. Two devices in the same VLAN require a Layer 3 switch to communicate. What
campus design model is used?
A. Remote VLANs

B. Campus VLANs

C. Local VLANs

D. End-to-end VLANs
5. Which of the following are required for dynamic VLAN assignment to ports with
VMPS?
A. VQP

B. VMPS server

C. VMPS client

D. TFTP server
6. Which VLAN database configuration mode command is used to remove VLAN 20?

A. erase vlan 20

B. clear vlan 20

C. delete vlan 20

D. no vlan 20
1439_CCNP_3.book Page 150 Wednesday, October 27, 2004 9:54 AM

150 Chapter 2: VLANs and VTP

7. What is the operational mode of a link when both ends are configured as dynamic
desirable?
A. Trunk

B. Static access
8. What three commands are used to restore a Catalyst 3550 switch to a default
configuration?
A. copy running-config startup-config

B. erase startup-config

C. delete vlan.dat

D. reload
9. Which construct can be used to filter both intra-VLAN and inter-VLAN traffic?

A. Router ACL

B. VLAN map

C. IOS ACL

D. Port ACL
10. Which of the following messages are used with VTP?

A. Join messages

B. Advertisement requests

C. Subset advertisements

D. Summary advertisements
1439_CCNP_3.book Page 151 Wednesday, October 27, 2004 9:54 AM
1439_CCNP_3.book Page 152 Monday, November 1, 2004 11:16 AM

Objectives
After completing this chapter, you will be able to perform tasks related to the following:
■ Explain the evolution of Spanning Tree Protocol (STP).
■ Understand and have the knowledge and skills to configure basic STP operations,
processes, and enhancements.
■ Have a basic understanding of Rapid Spanning Tree Protocol (RSTP).
■ Configure basic STP functions, operations, and tuning.
■ Verify and troubleshoot STP configuration.
■ Differentiate between Mono Spanning Tree and Multiple Spanning Tree, both of
which are abbreviated MST.
■ Configure EtherChannel.
1439_CCNP_3.book Page 153 Wednesday, October 27, 2004 9:54 AM

Chapter 3

Spanning Tree Protocol (STP)


Of all the protocols that network engineers spend time learning about and planning for, the one
that is probably overlooked the most is Spanning Tree Protocol (STP). As routers became pop-
ular in the early 1990s, STP faded into the background as a “less-important protocol that just
worked.” However, with switching technology now in the forefront, STP has once again earned
its place as an important consideration in network design.
A poorly planned initial implementation of STP can mean that an inordinate proportion of the
configuration, troubleshooting, and maintenance effort on a campus network becomes devoted
to STP. This chapter explains the mechanics of STP, detailing its loop-prevention function in
switched networks. Understanding these mechanics enables a proactive rather than reactive
approach to configuring STP on the target switched network.
STP is one of the most technical subjects in LAN switching. The challenge of understanding STP
is similar to that of understanding the underlying operation of Open Shortest Path First (OSPF)
or Enhanced Interior Gateway Routing Protocol (EIGRP) in a campus network (timers, packet
types, algorithms, and so on). It is essential to gain this understanding. STP serves as a funda-
mental logical building block in every campus network, and it plays a key role in network design
and implementation.
This chapter discusses Layer 2 techniques and technologies designed to optimize network reli-
ability, resiliency, and redundancy within a campus network. In particular, this chapter explores
scaling issues with STP as they pertain to virtual LANs (VLANs).
1439_CCNP_3.book Page 154 Wednesday, October 27, 2004 9:54 AM

154 Chapter 3: Spanning Tree Protocol (STP)

STP Operation
Broadcast storms and bridge table corruption are primary motivators for the use of STP in a
switched network. STP parameters such as Bridge Priority, Path Cost, and Port ID govern
STP’s behavior. This section discusses the motivators for STP and the parameters affecting its
behavior.

STP Concepts
STP is a Layer 2 protocol that uses a special-purpose algorithm to discover physical loops in
a network and effect a logical loop-free topology. STP creates a loop-free tree structure con-
sisting of leaves and branches that span the entire Layer 2 network. The actual mechanics of
how bridges communicate and how the STP algorithm works are discussed at length in this
chapter. Note that the terms bridge and switch are used interchangeably when discussing STP,
because with respect to the IEEE 802.1D STP specifications, there is no distinction between
bridges and switches. In addition, unless otherwise indicated, connections between switches
are assumed to be trunks.
The greater discussion of STP concerns its behavior on trunk connections, which form the
spanning tree. Loops can occur in a network for a variety of reasons. Usually, loops in a net-
work are the result of a deliberate attempt to provide redundancy. However, loops can also
result from configuration errors. Figure 3-1 shows a typical switched network and how physical
loops can be intentionally used to provide redundancy. Without STP, looping network traffic
would degrade performance to the extent that the network would be effectively unusable.
Physical loops without proper STP design can be disastrous. Two problems that can result are
broadcast storms and bridge table corruption. These phenomena are discussed in the next two
sections.

Broadcast Loops
Broadcasts and physical loops are a dangerous combination. Figure 3-2 shows how broadcast
loops are generated. Two switches, Cat-1 and Cat-2, have STP disabled. Host A and Host B
are connected to Cat-1 and Cat-2 by hubs.
1439_CCNP_3.book Page 155 Wednesday, October 27, 2004 9:54 AM

STP Operation 155

Figure 3-1 Physical Loops Provide Redundancy in Switched Networks

Server Farm

Wiring Closet Backbone

Cat-6 Cat-1 Cat-2

Cat-5

Cat-7 Cat-3 Cat-4 Hub

Figure 3-2 Broadcast Loops Would Occur in This Scenario Because STP Is Disabled

Host A

1/1 1/1

Cat-1 Cat-2
1/2 1/2

Host B
1439_CCNP_3.book Page 156 Wednesday, October 27, 2004 9:54 AM

156 Chapter 3: Spanning Tree Protocol (STP)

Host A sends a frame to the broadcast Media Access Control (MAC) address FF-FF-FF-FF-FF-FF,
which travels to both Cat-1 and Cat-2. When the frame arrives at Port 1/1 on Cat-1, Cat-1 fol-
lows the standard transparent bridging algorithm and floods the frame out all the other ports,
including Port 1/2. The frame exiting Port 1/2 travels to all nodes on the lower Ethernet seg-
ment, including Port 1/2 on Cat-2. Cat-2 floods the broadcast frame out all the other ports,
including Port 1/1, and, once again, the frame shows up at Port 1/1 on Cat-1. Oblivious to the
loop, Cat-1 sends the frame out Port 1/2 for the second time, and a broadcast loop is now in
effect. Recall that a switch does not forward a frame out the same port through which it entered
the switch.
The discussion so far has not mentioned that not only would Cat-1 have received the initial
broadcast from Host A, but Cat-2 would receive it as well. The same problem would propa-
gate in the reverse direction as a result. The “feedback” loop would occur in both directions.
An important conclusion to be drawn is that bridging loops are much more dangerous than
routing loops. Why is this? Suppose the initial broadcast frame were an Ethernet version II
frame, as shown in Figure 3-3.

Figure 3-3 The Format for the Ethernet Version II Frame Was Developed by Digital, Intel, and Xerox

Dest MAC Source MAC Type Data CRC

6 6 2 46-1500 4

The Ethernet version II frame contains only two MAC addresses, a Type field, the network-
layer packet as data, and a cyclic redundancy check (CRC). In contrast, an IP header contains
a Time-To-Live (TTL) field that is set by the source and is decremented at each router. By
discarding packets that reach TTL = 0, routers prevent “runaway” datagrams. Unlike IP,
Ethernet does not have a TTL field. Therefore, after a frame starts to loop in the network, as
just described, it continues until a switch is turned off or a link is broken. The network shown
in Figure 3-2 is extremely simple. Feedback loops of this type grow exponentially as addi-
tional switches and links are incorporated into the network. A single broadcast can render a
network unusable, all because STP is disabled or configured incorrectly.

Bridge Table Corruption


A less-understood problem than broadcast storms is unicast frames causing network bottle-
necks. Figure 3-4 illustrates how a unicast packet can cause such a problem.
1439_CCNP_3.book Page 157 Wednesday, October 27, 2004 9:54 AM

STP Operation 157

Figure 3-4 The MAC Address-to-Port Associations for Host A Flip-Flop on Cat-1 and Cat-2

Host A

1/1 1/1

Cat-1 Cat-2
1/2 1/2

Host B

Host A possesses a prior Address Resolution Protocol (ARP) entry for Host B and wants to
ping Host B. However, Host B has been temporarily removed from the network, and the cor-
responding bridge-table entries in the switches have been flushed for Host B. Assume that
neither switch is running STP. As with the previous example, the frame travels to Port 1/1 on
both switches. Consider the scenario relative to Cat-1 alone. Cat-1 does not have an entry for
the MAC address of Host B, BB-BB-BB-BB-BB-BB, in its bridging table; as a result, it
floods the frame to all other ports. Cat-2 then receives the frame on Port 1/2.
Two things happen at this point:
1. Cat-2 floods the frame because MAC address BB-BB-BB-BB-BB-BB is not in its
bridging table.
2. Cat-2 notices that it received a frame on Port 1/2 with a source MAC address of
AA-AA-AA-AA-AA-AA (from Host A).
As a result, Cat-2 changes its bridging table entry for the MAC address of Host A to the
wrong port.
As frames loop in the reverse direction (the feedback loop goes both ways), the MAC address
of Host A flip-flops between Port 1/1 and Port 1/2 on the switches. In short, not only does this
permanently saturate the network with the unicast ping packet, but it also corrupts the bridg-
ing tables and drives the switch CPU utilization to 100 percent (which prevents the switch
from forwarding traffic). This example demonstrates that broadcasts are not the only types of
frames that can bring down a network.
1439_CCNP_3.book Page 158 Wednesday, October 27, 2004 9:54 AM

158 Chapter 3: Spanning Tree Protocol (STP)

Bridge Priority
An algorithm is a formula or set of steps for solving a particular problem. Algorithms rely
on a set of rules. They have a clear beginning and end. The Spanning Tree Algorithm is no
exception.
The IEEE 802.1D standard defines the Spanning Tree Algorithm that characterizes STP. This
algorithm relies on the BID, Path Cost, and Port ID parameters to make decisions (the follow-
ing sections cover Path Cost and Port ID in greater detail).
The Bridge ID (BID) is the first parameter used by the Spanning Tree Algorithm. STP uses
the BID to determine the center of the bridged network, known as the Root Bridge or Root
Switch. The BID parameter is an 8-byte field consisting of an ordered pair of numbers, as
shown in Figure 3-5. The first is a 2-byte decimal number called the Bridge Priority, and
the second is a 6-byte (hexadecimal) MAC address. The Bridge Priority is a decimal number
used to measure the preference of a bridge in the Spanning Tree Algorithm. The possible values
range between 0 and 65,535. The default setting is 32,768.

Figure 3-5 The BID Consists of an Ordered Pair of Numbers, the Bridge Priority, and the
MAC Address

BID - 8 Bytes

Bridge Priority MAC

2 Bytes 6 Bytes
Range: 0-65,535 From Backplane/Supervisor
Default: 32,768

The MAC address in the BID is one of the switch’s MAC addresses. Each switch has a pool
of MAC addresses, one for each instance of STP, used as BIDs for the VLAN spanning-tree
instances (one per VLAN). For example, Catalyst 6000 switches each have a pool of 1024
MAC addresses assigned to the Supervisor module or backplane for this purpose.
The way to compare BIDs is as follows:
Let (s,t) and (u,v) represent two BIDs, where the first coordinate is the Bridge Priority and the
second coordinate is the MAC address (Priority, MAC address). Then (s,t) < (u,v) if and only if
■ s<u
or
■ s = u and t < v
1439_CCNP_3.book Page 159 Wednesday, October 27, 2004 9:54 AM

STP Operation 159

Two BIDs cannot be equal, because Catalyst switches are assigned unique MAC addresses.
In terms of the Spanning Tree Algorithm, when a comparison is made between two values of
a given STP parameter, the lower value is always preferred.

Path Cost
The Path Cost is the second parameter used by the Spanning Tree Algorithm to determine
the path to the Root Switch.
Path Cost is a measure of how close bridges are to each other. Path Cost is the sum of the
costs of the links in a path between two bridges. It is not a measure of hop count. The hop
count for Path A might be greater than the hop count for Path B, while the cost of Path A is
less than the cost of Path B. Closeness is not necessarily reflected by hop count.
Switches use the Path Cost to determine the best path to the Root Switch. The lowest combi-
nation of links has the lowest cumulative Path Cost and is the best path to the Root Switch.
The IEEE 802.1D standard originally defined the cost of a link as 1000 Mbps divided by the
link’s bandwidth in Mbps. For example, a 10BASE-T link has a cost of 100 (1000/10), and
Fast Ethernet and Fiber Distributed Data Interface (FDDI) each have a cost of 10 (1000/100).
With the advent of Gigabit Ethernet and other high-speed technologies, a problem with this
definition evolved.
The cost is stored as an integer value, not as a floating-point value. For example, 10 Gbps
results in 1000 Mbps/10000 Mbps = .1, an invalid cost value. To solve this problem, the IEEE
changed the “inverse proportion” definition. Table 3-1 shows the definition of the STP cost
for a link exceeding 1 Gbps on a CatOS switch (short mode). Table 3-2 shows the definition
of the STP cost for a link of 10 Gbps or higher on a CatOS switch (long mode). The default
cost mode for a CatOS switch can be manually configured; all switches in a network must use
the same default. On newer IOS-based switches such as the Catalyst 2950 and Catalyst 3550,
the valid range from which the STP cost can be assigned is 1 to 200,000,000.

Table 3-1 The CatOS STP Cost Definition Was Updated to Account for Links with Speeds Up to
10 Gbps (Short Mode)

Bandwidth STP Cost

4 Mbps 250

10 Mbps 100

16 Mbps 62

45 Mbps 39
continues
1439_CCNP_3.book Page 160 Wednesday, October 27, 2004 9:54 AM

160 Chapter 3: Spanning Tree Protocol (STP)

Table 3-1 The CatOS STP Cost Definition Was Updated to Account for Links with Speeds Up to
10 Gbps (Short Mode) (Continued)

Bandwidth STP Cost

100 Mbps 19

155 Mbps 14

622 Mbps 6

1 Gbps 4

10 Gbps 2

Table 3-2 The CatOS STP Cost Definition Was Again Updated to Account for Links with Speeds Up
to 10 Tbps (Long Mode)

Bandwidth STP Cost

4 kbps 200,000,000

1 Mbps 20,000,000

10 Mbps 2,000,000

100 Mbps 200,000

1 Gbps 20,000

10 Gbps 2000

100 Gbps 200

1 Tbps (terabits per second) 20


10 Tbps 2

Port ID
The Port ID is the third parameter used by the Spanning Tree Algorithm to determine the
path to the Root Switch. Figure 3-6 illustrates the Port ID, which is a 2-byte STP parameter
consisting of an ordered pair of numbers, the Port Priority and the Port Number.
1439_CCNP_3.book Page 161 Wednesday, October 27, 2004 9:54 AM

STP Processes 161

Figure 3-6 The Port ID

16 Bits

Port Priority Port Number

6 Bits 10 Bits

On a CatOS switch, the Port Priority is 6 bits and the Port Number is 10 bits. On an IOS-based
switch, both numbers are 8 bits.
Port ID should not be confused with the Port Number. The Port Number is just part of the Port ID.
Lower Port IDs are preferred over higher Port IDs in the STP decision process. The order
relation for Port IDs is explained in the following example.
If (s,t) and (u,v) represent two Port IDs (the first coordinate being the Port Priority and the
second coordinate being the Port Number), (s,t) < (u,v) if and only if
■ s<u
■ s = u and t < v
Two Port IDs cannot be equal, because Port Numbers uniquely identify the switch ports on a
Catalyst switch.
The Port Priority is a configurable STP parameter (unlike the Port Number), with values
ranging from 0 to 255 on an IOS-based switch (the default value is 128).
Port Numbers are numerical identifiers used by Catalyst switches to enumerate the ports. The
Port Number leaves room for 28 (256) ports on an IOS-based switch (Cisco routers also use
the 8-bit/8-bit Port ID definition).

STP Processes
This section provides details of exactly how IEEE 802.1D STP works by describing the three
steps of STP convergence, as well as the election of the Root Switch, Root Port, and Desig-
nated Port. Furthermore, this section explores STP timers and the process of topology
change.
1439_CCNP_3.book Page 162 Wednesday, October 27, 2004 9:54 AM

162 Chapter 3: Spanning Tree Protocol (STP)

STP Decisions and BPDU Exchanges


The Spanning Tree Algorithm operates as a function of the BID, Path Cost, and Port ID.
When creating a loop-free logical topology, STP always uses the same four-step decision
sequence:
Step 1 Determine the Root Switch.
Step 2 Calculate the lowest Path Cost to the Root Switch.
Step 3 Determine the lowest sender BID.
Step 4 Determine the lowest Port ID.
Figure 3-7 illustrates this sequence.

Figure 3-7 The Four-Step Decision Process of STP

Root BID Who is the root bridge?

Root Path Cost How far away is the root bridge?

Sender BID What is the BID of the bridge that


sent this BPDU?
Port ID What port on the sending bridge
did this BPDU come from?

As a clarification, Step 1 is essentially the election of the switch that has the lowest BID when
compared with other switches in the topology. This is fully discussed in the following sec-
tions.
To make good decisions, STP needs to ensure that the participating bridges have the correct
information. The bridges need to communicate the STP information between them. Bridges
pass spanning-tree information between them using Layer 2 frames called bridge protocol
data units (BPDUs). A bridge uses the four-step decision sequence to determine the “best”
BPDU seen on each port. The bridge determines the best BPDU based on the four-step STP
process. The bridge stores the best BPDU it receives for each port. When making this evalua-
tion, it considers all the BPDUs received on the port, as well as the BPDU it would send on
that same port.
1439_CCNP_3.book Page 163 Wednesday, October 27, 2004 9:54 AM

STP Processes 163

As each BPDU arrives at the switch port, it is checked against this four-step sequence to see
if it is more attractive than the existing BPDU saved for that port. If the new BPDU (or the
locally generated BPDU) is more attractive, the old value is replaced.
Additionally, this “saving-the-best-BPDU” process also controls the sending of BPDUs. When
a bridge first becomes active, all its ports send BPDUs every 2 seconds (the default Hello Time).
However, if a port hears about a BPDU from another bridge that is more attractive than the
BPDU it has been sending, the local port eventually stops sending BPDUs. If the more-
attractive BPDU stops arriving from a neighbor for 20 seconds (the default Max Age), the local
port resumes sending BPDUs. Max Age is the time it takes for the best BPDU to time out.

Three Steps of STP Convergence


The Spanning Tree Algorithm is somewhat complex, but the initial process used to converge NOTE
on a loop-free topology consists of three election steps: The default configura-
tion for Catalyst switches
Step 1 Elect a Root Switch. is to run one instance
of the Spanning Tree
Step 2 Elect Root Ports. Algorithm per VLAN.
Step 3 Elect Designated Ports.
Figure 3-8 illustrates Root Port election.

Figure 3-8 Root Port Election is the Second Step

BID =
32,768.AA-AA-AA-AA-AA-AA

Cat-A
1/1 1/2

1/1 1/1

Cat-B Cat-C
1/2 1/2

BID = BID =
32,768.BB-BB-BB-BB-BB-BB 32,768.CC-CC-CC-CC-CC-CC

When the network first “starts,” all the bridges flood it with a mixture of BPDU information.
The bridges begin applying the STP four-step decision sequence discussed in the preceding
section. This allows the bridges to hone in on a set of BPDUs that enable the formation of a
single spanning tree for the entire network or VLAN.
1439_CCNP_3.book Page 164 Wednesday, October 27, 2004 9:54 AM

164 Chapter 3: Spanning Tree Protocol (STP)

A single Root Switch is elected to act as the central point of this network (Step 1). All the
remaining bridges calculate a set of Root Ports (Step 2) and Designated Ports (Step 3) to
build a loop-free topology. The resulting topology is a tree, with the Root Switch as the trunk
and loop-free active paths radiating outward as tree branches. In a steady-state network,
BPDUs flow from the Root Switch outward along these loop-free branches to every segment
in the network. After the network has converged on a loop-free active topology using this
three-step process, changes are handled using the spanning-tree topology change process.
The following sections consider the three steps of STP convergence in detail.

Electing the Root Switch


As a first step in the STP process, the switches need to elect a single Root Switch by looking
for the bridge with the lowest BID. This process of selecting the bridge with the lowest BID
is sometimes called the “root war.”
As discussed in the earlier “Bridge Priority” section, a BID is an 8-byte identifier that is com-
posed of two subfields, the Bridge Priority and a MAC address. As Figure 3-8 illustrates, Cat-A
has a default BID of 32,768.AA-AA-AA-AA-AA-AA, Cat-B assumes a default BID of
32,768.BB-BB-BB-BB-BB-BB, and Cat-C uses 32,768.CC-CC-CC-CC-CC-CC. Because
all three bridges use the default Bridge Priority of 32,768, the lowest MAC address,
AA-AA-AA-AA-AA-AA, serves as the tiebreaker, and Cat-A becomes the Root Switch. The
process of how to configure a switch to become the Root Switch is examined in the following
sections. Normally, the default settings should not be allowed to determine the location of the
Root Switch. How did the bridges learn that Cat-A has the lowest BID? This is accomplished
through the exchange of BPDUs. As discussed earlier, BPDUs are special frames that bridges
use to exchange spanning-tree information with each other. By default, BPDUs are sent every
2 seconds. BPDUs propagate between bridges, which includes switches and all routers configured
for bridging. BPDUs do not carry end-user traffic. Figure 3-9 illustrates the layout of a BPDU.

Figure 3-9 A BPDU Includes Root BID, Root Path Cost, Sender BID, and Port ID Information

Root BID Who is the root bridge?

Root Path Cost How far away is the root bridge?

Sender BID What is the BID of the bridge that


sent this BPDU?
Port ID What port on the sending bridge
did this BPDU come from?
1439_CCNP_3.book Page 165 Wednesday, October 27, 2004 9:54 AM

STP Processes 165

For the purposes of the root war, this discussion involves only the Root BID and Sender BID
fields. When a bridge generates a BPDU every 2 seconds, the bridge places what it thinks is
the Root Switch at that instant in the Root BID field. The bridge always places its own BID in
the Sender BID field. Initially, before the switch knows any better, it populates the Root BID
field with its own BID. Suppose that Cat-B boots first and starts sending out BPDUs announc-
ing itself as the Root Switch every 2 seconds. A few minutes later, Cat-C boots and announces
itself as the Root Switch. When the Cat-C BPDU arrives at Cat-B, Cat-B discards the BPDU
because it has a lower BID saved on its ports (its own BID). As soon as Cat-B transmits a
BPDU, Cat-C learns that it is not as important as it initially thought. At this point, Cat-C starts
sending BPDUs that list Cat-B as the Root BID and Cat-C as the sender BID. The network now
agrees that Cat-B is the Root Switch. Five minutes later, Cat-A boots. Cat-A initially thinks it is
the Root Switch and starts advertising this fact via BPDUs. As soon as these BPDUs arrive at
Cat-B and Cat-C, the switches hand over the Root Switch position to Cat-A. All three switches
now send BPDUs that announce Cat-A as the Root Switch and themselves as the sender BID.

Electing Root Ports


At the conclusion of the root war, the switches move on to selecting Root Ports. A bridge’s
Root Port is the port that is closest to the Root Switch in terms of Path Cost. Every non-Root
Switch must select one Root Port. Again, bridges use the concept of cost to measure closeness.
As with some routing metrics, the measure of closeness using STP is not necessarily reflected
by hop count. Specifically, bridges track the Root Path Cost, the cumulative cost of all links
to the Root Switch. Figure 3-10 illustrates how this value is calculated across multiple
bridges and the resulting Root Port election process.

Figure 3-10 Root Ports Are Elected After the Root Switch Is Elected

Root Bridge

Cost = 19 1/1 1/2 Cost = 19


Cat-A
BPDU BPDU
Cost = 0 Cost = 0

BPDU BPDU
1/1 1/1
Cost = X
0 19 Cost = X
0 19
Root Port Root Port

Cat-B Cat-C
BPDU
1/2 BPDU 1/2
Cost = 19 X 38
Cost = 19

Cost = 19
BPDU
Cost = 19
1439_CCNP_3.book Page 166 Wednesday, October 27, 2004 9:54 AM

166 Chapter 3: Spanning Tree Protocol (STP)

When Cat-A (the Root Switch) sends out BPDUs, they contain a Root Path Cost of 0. When
Cat-B receives these BPDUs, it adds the Path Cost of Port 1/1 to the Root Path Cost con-
tained in the received BPDU. Assume that the network is running Fast Ethernet:
1. Cat-B receives a Root Path Cost of 0 and adds in the Port 1/1 cost of 19.

2. Cat-B uses the value of 19 internally and sends BPDUs with a Root Path Cost of
19 out Port 1/2.
3. When Cat-C receives these BPDUs from Cat-B, it increases the Root Path Cost to
38 (19 + 19).
4. However, Cat-C is also receiving BPDUs from the Root Switch on Port 1/1.

5. These BPDUs enter Port 1/1 on Cat-C with a cost of 0, and Cat-C increases the cost
to 19 internally. Cat-C has a decision to make.
6. Cat-C must select a single Root Port—the port that is closest to the Root Switch.

7. Cat-C sees a Root Path Cost of 19 on Port 1/1 and 38 on Port 1/2. Port 1/1 on Cat-C
becomes the Root Port.
8. Cat-C begins advertising this Root Path Cost of 19 to downstream switches.

Cat-B goes through a similar set of calculations. Port 1/1 on Cat-B can reach the Root Switch
at a cost of 19, whereas Port 1/2 on Cat-B calculates a cost of 38. Port 1/1 becomes the Root
Port for Cat-B. The costs increment as BPDUs are received on a port, not as they are sent out
the port. For example, BPDUs arrive on Port 1/1 on Cat-B with a cost of 0 and get increased
to 19 “inside” Cat-B.

Electing Designated Ports


At this point, the Spanning Tree Algorithm still has not eliminated any loops. This is taken
care of after the Designated Ports and non-Designated Ports are determined. Each segment in
a bridged network has one Designated Port. A Designated Port for a segment is the bridge
port connected to that segment that both sends traffic toward the Root Switch and receives
traffic from the Root Switch over that segment. The idea behind this is that if only one port
handles traffic for each link, all the loops have been broken. The Designated Bridge for a seg-
ment is the bridge containing the Designated Port for that segment.
With the Root Port selection, the Designated Ports are chosen based on the Root Path Cost to
the Root Switch, as shown in Figure 3-11.
1439_CCNP_3.book Page 167 Wednesday, October 27, 2004 9:54 AM

STP Processes 167

Figure 3-11 Designated Ports Are Elected After the Root Switch and Root Ports Are Elected

Root Bridge
Segment 1 Segment 2
1/1 Cat-A 1/2

Designated
Designated
Port
Port

BID =
1/1 32,768.BB-BB 1/1
BB-BB-BB-BB
BID =
Cat-B 32,768.CC-CC- Cat-C
1/2 Designated CC-CC-CC-CC 1/2
Port
Segment 3

The Root Path Cost is the cumulative cost of all links leading to the Root Switch. Segment 1
forms a link between Cat-A and Cat-B. This segment has two bridge ports, Port 1/1 on Cat-A
and Port 1/1 on Cat-B. Port 1/1 on Cat-A has a Root Path Cost of 0 because Cat-A is the Root
Switch. Port 1/2 on Cat-A has a Root Path Cost of 0 because Cat-A is the Root Switch. Port 1/1
on Cat-B has a Root Path Cost of 19—the value 0 received in BPDUs from Cat-A plus the
Path Cost of 19 assigned to Port 1/1 on Cat-B. Because Port 1/1 Cat-A has the lower Root
Path Cost, it becomes the Designated Port for this link. For Segment 2, the Cat-A-to-Cat-C
link, a similar election takes place. Port 1/2 on Cat-A has a Root Path Cost of 0, whereas Port
1/1 on Cat-C has a Root Path Cost of 19. Port 1/2 on Cat-A has the lower cost and becomes
the Designated Port. Notice that every active port on the Root Switch becomes a Designated
Port.
Examining Segment 3, the link from Cat-B to Cat-C, both Port 1/2 on Cat-B and Port 1/2 on
Cat-C have a Root Path Cost of 19, resulting in a tie. When faced with a tie, STP always uses
the STP four-step decision sequence discussed earlier. Recall that the four steps are as follows:
Step 1 Determine the Root Switch.
Step 2 Calculate the lowest Root Path Cost.
Step 3 Determine the lowest sender BID.
Step 4 Determine the lowest Port ID.
1439_CCNP_3.book Page 168 Wednesday, October 27, 2004 9:54 AM

168 Chapter 3: Spanning Tree Protocol (STP)

All three bridges shown in Figure 3-11 agree that Cat-A is the Root Switch, so the algorithm
checks Root Path Cost next. However, both Cat-B and Cat-C have a cost of 19, so the algorithm
resorts to the lowest sender BID. Because the Cat-B BID (32,768.BB-BB-BB-BB-BB-BB)
is lower than the Cat-C BID (32,768.CC-CC-CC-CC-CC-CC), Cat-B:Port 1/2 becomes the
Designated Port for Segment 3. Cat-C:Port 1/2 becomes a non-Designated Port. Note that
access ports do not play a role in the election of Designated Ports. Trunk ports are used to
connect to other switches. Access ports are used to connect to hosts or routers. The process
described here involves communication of STP parameters over trunk links.

STP States
After the bridges have determined which ports are Root Ports, Designated Ports, and non-
Designated Ports, STP is ready to create a loop-free topology. To do this, STP configures
Root Ports and Designated Ports to forward traffic. STP sets non-Designated Ports to block
traffic. Although Forwarding and Blocking are the only two states commonly seen in a stable
network, there are actually five STP states, as described in Table 3-3.

Table 3-3 STP States

State Description

Forwarding Sends and receives user data

Learning Builds the bridging table

Listening Builds the “active” topology

Blocking Receives BPDUs only

Disabled Administratively down

The STP states can be viewed hierarchically in that bridge ports start at the Blocking state
and work their way up to the Forwarding state. The Disabled state is the administratively shut
down STP state. It is not part of the normal STP port processing. After the switch is initial-
ized, ports start in the Blocking state. The Blocking state is the STP state in which a bridge
listens for BPDUs.

Blocking State
A port in the Blocking state has the following characteristics and functions:
■ It discards frames received from the attached segment or internally forwarded through
switching.
1439_CCNP_3.book Page 169 Wednesday, October 27, 2004 9:54 AM

STP Processes 169

■ It receives BPDUs and directs them to the system module.


■ It has no address database.
■ It does not transmit BPDUs received from the system module.
■ It receives and responds to network management messages but does not transmit them.

Listening State
If a bridge thinks it is the Root Switch immediately after booting or in the absence of BPDUs
for a certain period of time, the port transitions into the Listening state. The Listening state
is the STP state in which no user data is being passed, but the port is sending and receiving
BPDUs in an effort to determine the active topology.
A port in the Listening state has the following characteristics and functions:
■ It discards frames received from the attached segment or frames switched from
another port.
■ It has no address database.
■ It receives BPDUs and directs them to the system module.
■ It processes BPDUs received from the system module. (Processing BPDUs is a
separate action from receiving or transmitting BPDUs.)
■ It receives and responds to network management messages.
The three initial convergence steps—electing a Root Switch, Root Ports, and Designated
Ports—take place during the Listening state. Ports that lose the Designated Port election
become non-Designated Ports and drop back to the Blocking state. Ports that remain
Designated Ports or Root Ports after 15 seconds—the default Forward Delay STP timer
value—progress into the Learning state.

Learning State
The Learning state is the STP state in which the bridge is doesn’t pass user data frames but
builds the bridging table and gathers information, such as the source VLANs of data frames.
As the bridge receives a frame, it places the source MAC address and port into the bridging
table. The Learning state reduces the amount of flooding required when data forwarding
begins. The lifetime of the Learning state is also governed by the Forward Delay timer of
15 seconds, the default setting.
A port in the Learning state has the following characteristics and functions:
■ It discards frames received from the attached segment.
■ It discards frames switched from another port for forwarding.
■ It incorporates station location into its address database.
1439_CCNP_3.book Page 170 Wednesday, October 27, 2004 9:54 AM

170 Chapter 3: Spanning Tree Protocol (STP)

■ It receives BPDUs and directs them to the system module.


■ It receives, processes, and transmits BPDUs received from the system module.
■ It receives and responds to network management messages.

Forwarding State
If a port is still a Designated Port or Root Port after the Forward Delay timer expires for the
Learning state, the port transitions into the Forwarding state. The Forwarding state is the
STP state in which data traffic is both sent and received on a port. It is the “last” STP state. At
this stage, it finally starts forwarding user data frames.
A port in the Forwarding state has the following characteristics and functions:
■ It forwards frames received from the attached segment.
■ It forwards frames switched from another port for forwarding.
■ It incorporates station location information into its address database.
■ It receives BPDUs and directs them to the system module.
■ It processes BPDUs received from the system module.
■ It receives and responds to network management messages.

Transitions Between STP States


Figure 3-12 illustrates the transitions between STP states. The scenario in Figure 3-13 shows
Root Ports, Designated Ports, and non-Designated Ports and the associated STP states.

Figure 3-12 Various Events Trigger Transitions Between STP States

2
2 Listening

3 5
1 4
Disabled 4
Blocking Learning
or Down
2 7
6 4
2 5
Forwarding

Legend of Events:
1. Port Enabled or Initialized
2. Port Disabled or Fails
3. Port Selected as Root or Designated Port
4. Port Ceases to be a Root or Designated Port
5. Forwarding Timer Expires
6. PortFast
7. UplinkFast
1439_CCNP_3.book Page 171 Wednesday, October 27, 2004 9:54 AM

STP Processes 171

Figure 3-13 Root Ports, Designated Ports, and Non-Designated Ports and the Associated STP
States in a Stable STP Topology

Root Bridge
Segment 1 Forwarding 1/1 1/2 Forwarding Segment 2
Cat-A
Designated Designated
Port Port

Forwarding Root Port Root Port Forwarding

1/1 1/1

Cat-B Cat-C
1/2 1/2
Designated Non-Designated
Forwarding Port Port Blocking

Segment 3

STP Timers
STP operation is controlled by three timers, as described in Table 3-4.

Table 3-4 Three Timers Used with STP

Timer Primary Purpose Default

Hello Time The amount of time between the sending of Configuration 2 seconds
BPDUs by the Root Switch

Forward Delay The duration of the Listening and Learning states 15 seconds

Max Age How long a BPDU is stored 20 seconds

The Hello Time is the amount of time between the sending of Configuration BPDUs. The
802.1D standard specifies a default value of 2 seconds. This value controls Configuration
BPDUs as the Root Switch generates them. Other bridges propagate BPDUs from the Root
Switch as they are received.
If BPDUs stop arriving for the time interval ranging from 2 to 20 seconds because of a net-
work disturbance, or if the Root Switches stop sending periodic BPDUs during this time,
the timer expires. The range between the expected receipt of a BPDU and the expiration of
1439_CCNP_3.book Page 172 Wednesday, October 27, 2004 9:54 AM

172 Chapter 3: Spanning Tree Protocol (STP)

the Max Age time is 2 to 20 seconds. If the outage lasts for more than 20 seconds (the default
Max Age time), the bridge invalidates the saved BPDUs and begins looking for a new Root
Port.
Forward Delay is the amount of time the bridge spends in the Listening and Learning states.
This is a single value that controls both states. The default value of 15 seconds was originally
derived assuming a maximum network size of seven bridge hops, a maximum of three lost
BPDUs, and a Hello Time of 2 seconds. The Forward Delay timer also controls the bridge
table age-out period after a change in the active topology.
Max Age is the STP timer that controls how long a bridge stores a BPDU before discarding
it. Max Age is an issue only when the link failure is not on a directly connected link. When a
failure occurs on a directly connected link, the switch knows that no BPDUs will be coming
in on that link, so Max Age is not considered in transitioning the port to Forwarding state.
Recall that each port saves a copy of the best BPDU it has seen. As long as the bridge
receives a continuous stream of BPDUs every 2 seconds, Max Age does not come into play.
However, if the device sending this best BPDU fails, a mechanism must exist to allow other
bridges to take over.
For example, assume that the Segment 3 link shown in Figure 3-14 uses a hub and that Port 1/2
on the Cat-B transceiver fails. Cat-C receives no immediate notification of the failure, because it
still has an active Ethernet link to the hub. The only thing Cat-C knows is that BPDUs stop
arriving. Twenty seconds (Max Age) after the failure, Port 1/2 on Cat-C ages out the BPDU
information that lists Cat-B as having the best Designated Port for Segment 3. This forces
Port 1/2 on Cat-C to transition to the Listening state in an effort to become the Designated
Port. Because Port 1/2 on Cat-C now offers the most attractive access from the Root Switch
to this link, it eventually transitions all the way into Forwarding state. In this example, with a
hub between Cat-B and Cat-C, it takes approximately 50 seconds (20 Max Age + 15 Listen-
ing + 15 Learning) for Cat-C to take over after the failure of Port 1/2 on Cat-B. In some situ-
ations, switches can detect topology changes on directly connected links and immediately
transition into the Listening state without waiting Max Age seconds.
For example, in Figure 3-15, Port 1/1 on Cat-C fails. Because the failure results in a loss of
link on the Root Port, there is no need to wait 20 seconds for the old information to age out.
Note the difference between this scenario and the one in Figure 3-14, where link integrity was
maintained because of the presence of a hub. When Port 1/1 on Cat-C fails, Port 1/2 on Cat-C
immediately goes into Listening state in an attempt to become the new Root Port. The STP
convergence time decreases from 50 seconds to 30 seconds (15 Listening + 15 Learning). So
the port moves into Forwarding state within 30 seconds.
1439_CCNP_3.book Page 173 Wednesday, October 27, 2004 9:54 AM

STP Processes 173

Figure 3-14 A Hub Connects Cat-B and Cat-C in a Converged STP Topology

Root Bridge
Segment 1 Forwarding 1/1 1/2 Forwarding Segment 2
Cat-A
Designated Designated
Port Port

Forwarding Root Port Root Port Forwarding

1/1 1/1

Cat-B Cat-C
1/2 1/2
Designated Non-Designated
Forwarding Port Port Blocking

Figure 3-15 Port 1/1 on Cat-C Fails

Root Bridge
Segment 1 Forwarding 1/1 1/2 Forwarding Segment 2
Cat-A
Designated Designated
Port Port
X
Forwarding Root Port

1/1 1/1

Cat-B Cat-C
1/2 1/2
Designated
Forwarding Port Root Port Forwarding

Segment 3
1439_CCNP_3.book Page 174 Wednesday, October 27, 2004 9:54 AM

174 Chapter 3: Spanning Tree Protocol (STP)

There are two key points to remember about using the STP timers:
■ Default timer values should not be changed without careful consideration.
■ If timer tuning is attempted, modify the STP timers only from the Root Switch, because
the BPDUs contain three fields with timer values that can be passed from the Root Switch
to all other bridges in the network. If every bridge were locally configured, some bridges
could work their way up to the Forwarding state before other bridges ever left the
Listening state. This chaotic approach could quickly lead to an unstable network. By
providing timer fields in the BPDUs, the single bridge acting as the Root Switch can
dictate the timing parameters for the entire bridged network.

BPDU Format
The format of a STP BPDU frame varies depending on the type of protocol used. Figure 3-16
shows the format of an IEEE 802.1D Spanning Tree Protocol BPDU frame. Figure 3-17 shows
the format of a Cisco STP BPDU frame.

Figure 3-16 IEEE 802.1D Is the Original Specification for STP

Frame Destination Source Logical Link IEEE BPDU


Control Address Address Control
(1 Byte) (6 Bytes) (6 Bytes) (3 Bytes)

Figure 3-17 Cisco Catalyst Switches Use a Proprietary BPDU Frame Format

Frame Destination Source Routing Logical Link IEEE BPDU


Control Address Address Information Control
(1 Byte) (6 Bytes) (6 Bytes) Field (Variable) (3 Bytes)

The fields shown in both Figures 3-16 and 3-17 are as follows:
■ The Frame Control field is always 01.
■ The Destination Address field indicates the destination address as specified in the
Bridge Group Address table. For IEEE STP BPDU frames, the address is
0x800143000000.
■ The Source Address field indicates the base MAC address used by the switch. For
Cisco STP BPDU frames, the multicast bit is set to indicate the presence of a Routing
Information Field (RIF) in the header.
1439_CCNP_3.book Page 175 Wednesday, October 27, 2004 9:54 AM

STP Processes 175

■ The Routing Information field is applicable only to Cisco STP BPDU frames. The RIF
must be set to 0x0200.
■ The Logical Link Control field controls all types of STP BPDU frames. This field is set
to 0x424203.
Figure 3-18 shows the format of the fields inside a BPDU. All fields in the BPDU are common
to all STPs except for the Port ID field. For IEEE and Cisco STP BPDU frames, the Port ID
field specifies the transmitting Port Number of the originating bridge.

Figure 3-18 Fields in the BPDU

Protocol Version Message Flags Root Root Bridge ID Port ID Message Maximum Hello Forward
Identifier (1 Byte) Type (1 Byte) ID Path (8 Bytes) (2 Bytes) Age Age Time Delay
(2 Bytes) (1 Byte) (8 Bytes) Cost (2 Bytes) (2 Bytes) (2 Bytes) (2 Bytes)
(4 Bytes)

The Protocol Identifier, Version, and Message Type fields are all set to 0.
The Flags field includes one of the following:
■ A Topology Change (TC) bit, which signals a topology change and designates this
BPDU as a Topology Change Notification (TCN) BPDU. Without this bit set, the
BPDUs are Configuration BPDUs.
■ A Topology Change Acknowledgment (TCA) bit, which is set to acknowledge receipt
of a configuration message with the TC bit set.
The remaining fields contained in a BPDU frame are as follows:
■ The Root ID field indicates the Root Switch by listing its 2-byte priority followed by its
6-byte ID.
■ The Root Path Cost field indicates the path’s cost from the bridge sending the configu-
ration message to the Root Bridge.
■ The BID field indicates the priority and ID of the bridge sending the message.
■ The Port ID field indicates the Port Number (IEEE or Cisco STP BPDU) from which
the configuration message was sent. This field allows loops created by multiple
attached bridges to be detected and corrected.
■ The Message Age field indicates how much time has elapsed since the root sent the
configuration message on which the current configuration message is based.
■ The Maximum Age field indicates when the current configuration message should be
deleted.
■ The Hello Time field indicates the time between Root Bridge configuration messages.
1439_CCNP_3.book Page 176 Wednesday, October 27, 2004 9:54 AM

176 Chapter 3: Spanning Tree Protocol (STP)

■ The Forward Delay field indicates how long bridges should wait before transitioning to
a new state after a topology change. If a bridge transitions too soon, it is possible that
not all network links will be ready to change their state, and loops can result.

Topology Changes and STP


STP implements a series of timers to prevent bridging loops from occurring within the net-
work. It can take from 30 to 50 seconds for a network to converge to a new topology when a
change occurs in an otherwise stable STP process.
While the network is converging, physical addresses that can no longer be reached are still
listed in the switch table. Because these addresses are in the table, the switch attempts to
forward frames to devices it cannot reach. Fortunately, the STP change process requires the
switch to clear the table faster to get rid of unreachable physical addresses.
Figure 3-19 illustrates a link failure between Switch D and Switch E, which in turn triggers
a topology change condition. This topology change condition triggers a Topology Change
Notification BPDU to be generated and sent toward the Root Switch. For this BPDU to reach
the Root Switch, each switch forwards the update out the Root Port (RP in the figure) and
toward the Designated Port (DP in the figure) of each Designated Bridge along the path to the
Root Switch.

Figure 3-19 A Link Failure Triggers a Topology Change, Which STP Handles Via Built-in
Mechanisms

500:000000000001
Switch B Regenerates
Topology Change BPDU DP
Root A DP
1 2

RP
RP
32768:000000000002 1 1 32768:000000000004
B 2 2 C
DP DP

NDP
1 2
Switch D Generates RP

Topology Change BPDU


D 3 E
32768:000000000003

The topology change in this spanning-tree network triggers the following steps:
Step 1 Switch D notices that a change to a link has occurred.
1439_CCNP_3.book Page 177 Wednesday, October 27, 2004 9:54 AM

STP Enhancements 177

Step 2 Switch D sends a Topology Change Notification (TCN) BPDU out the Root
Port destined ultimately for the Root Switch. The TCN BPDU is indicated by
the value 0x80 in the BPDU’s 1-byte Type field. The bridge sends out the TCN
BPDU until the Designated Bridge for that segment responds with a TCA Con-
figuration BPDU, indicated by the high-order bit in the 1-byte Flag field.
Step 3 The Designated Bridge (Switch B) for that segment sends out a TCA Configu-
ration BPDU to the originating bridge (Switch D). Switch B also sends a TCN
BPDU out the Root Port destined for the Root Switch.
Step 4 When the Root Switch receives the (upstream) TCN BPDU, it sends Configu-
ration BPDUs to indicate that a topology change is occurring (using the low-
order bit in the Flag field). The Root Switch sets the topology change in the
configuration for a period of time equal to the sum of the Forward Delay and
Max Age parameters.
Step 5 A bridge receiving a (downstream) topology change configuration message
from the Root Switch uses the Forward Delay timer (15 seconds) to age out
entries in the address table. This allows the device to age out entries faster than
the normal 5-minute default so that stations that are no longer available are
aged out faster. The bridge continues this process until it no longer receives
topology change configuration messages from the Root Switch.

STP Enhancements
Cisco implemented several proprietary improvements to IEEE 802.1D STP to speed conver-
gence in certain situations. PortFast allows immediate conversion to the Forwarding state on
ports connected to workstations, servers, or routers (access ports). UplinkFast speeds up STP
convergence on uplink trunk ports when redundant uplinks are available and one of them
fails. BackboneFast speeds up STP convergence when an indirect trunk link goes down.

Delay in STP Updates


The current IEEE 802.1D STP standard was designed at a time when recovering connectivity
after an outage within a minute or so was considered adequate performance. With the advent
of Layer 3 switching in LAN environments, Layer 2 switching (as illustrated in Figure 3-20)
competes with routed solutions where protocols, such as OSPF and EIGRP, can provide an
alternate path in less time.
1439_CCNP_3.book Page 178 Wednesday, October 27, 2004 9:54 AM

178 Chapter 3: Spanning Tree Protocol (STP)

Figure 3-20 A Traditional Switched Campus Network Was Layer 2 Switched Throughout

IDF IDF
Access

IDF IDF

Distribution
MDF MDF MDF MDF

Layer 2

Core Core Core

Server Farm

Enhancements to the IEEE 802.1D specification have been developed in an attempt to speed
up STP alternate path selection. These areas are discussed in the following sections.

PortFast
STP PortFast is a Catalyst feature that causes a switch or trunk port to enter the STP For-
warding state immediately, bypassing the Listening and Learning states. IOS-based switches
use PortFast only on access ports connected to end stations, as shown in Figure 3-21.
When a device is connected to a port, the port normally enters the Listening state. When the
Forward Delay timer expires, the port enters the Learning state. When the Forward Delay
timer expires a second time, the port is transitioned to the Forwarding or Blocking state.
When PortFast is enabled on a switch or trunk port, the port is immediately transitioned to
the Forwarding state. As soon as the switch detects the link, the port is transitioned to the
Forwarding state (less than 2 seconds after the cable is plugged in).
1439_CCNP_3.book Page 179 Wednesday, October 27, 2004 9:54 AM

STP Enhancements 179

Figure 3-21 PortFast Is an Extremely Useful Option for Access Switch Ports Connected to Hosts

Catalyst 3550
Series Switch

Catalyst 2950 Catalyst 2950-T Server


Switch Switch

PortFast-
Enabled
Ports

Workstations Workstations

If a loop is detected and PortFast is enabled, the port is transitioned to the Blocking state. It is
important to note that PortFast begins only when the port first initializes. If the port is forced
into the Blocking state for some reason and later needs to return to the Forwarding state, the
usual Listening and Learning processes are performed. (Note the difference here from the
usual PortFast operation when a link first initializes.)
A primary reason for enabling PortFast is in cases where a PC boots in a period less than the
30 seconds it takes for a switch to put a port into Forwarding state from Disconnected state.
Some network interface card (NICs) do not enable a link until the MAC layer software driver
is actually loaded. Most operating systems try to use the network almost immediately after
the driver is loaded, as in the case of Dynamic Host Configuration Protocol (DHCP). This can
create a problem, because the 30 seconds of STP delay from listening to Forwarding states
begins right when the IOS begins trying to access the network. In the case of DHCP, the PC
does not obtain a valid IP address from the DHCP server. This problem is common with PC
Card (PCMCIA) NICs used in laptop computers. Additionally, there is a race between operat-
ing systems and CPU manufacturers. CPU manufacturers keep making the chips faster while
operating systems keep slowing down, but the chips are speeding up at a greater rate than the
operating systems are slowing down. As a result, PCs are booting faster than ever. In fact, modern
machines are often finished booting and need to use the network before the STP 30-second
delay is over.
1439_CCNP_3.book Page 180 Wednesday, October 27, 2004 9:54 AM

180 Chapter 3: Spanning Tree Protocol (STP)

This problem motivates some network administrators to disable STP altogether. This cer-
tainly fixes any STP booting problems, but it can easily create other problems. If this strategy
is employed, all physical loops must be eliminated, meaning no redundancy. STP cannot be
disabled for a single port, so the PortFast feature should be considered. The PortFast feature
gives the best of both worlds—immediate end-station access and the safety net of STP. The
later section “Configuring PortFast” details the procedures for configuring this feature on a
Catalyst switch.

UplinkFast
During the time it takes for STP to converge, some end stations might become inaccessible,
depending on the STP state of the switch port to which the station is attached. This disrupts
network connectivity, so it would be advantageous to decrease STP convergence time and
reduce the length of the disruption. UplinkFast was developed to facilitate fast STP conver-
gence. UplinkFast is a Catalyst feature that accelerates the choice of a new Root Port when a
link or switch fails.
Switches in hierarchical networks can be grouped into core layer switches, distribution layer
switches, and access layer switches. Figure 3-22 shows a portion of a campus network in
which distribution switches and access switches each have at least one redundant link that
STP blocks to prevent loops. If a switch loses connectivity on a link, it begins using the alter-
native paths as soon as STP selects a new Root Port. When STP reconfigures the new Root
Port, other interfaces flood the network with multicast packets, at least one for each address
that was learned on the interface.

Figure 3-22 Redundancy Is Critical for a Robust Network Design

Root Switch
Core
Switches 3550 3550

Distribution
Switches 2900 2950T 3500 XL

2950 2950 2950 2950


Access Switches

Active Link
Blocked Link
1439_CCNP_3.book Page 181 Wednesday, October 27, 2004 9:54 AM

STP Enhancements 181

UplinkFast accelerates the choice of a new Root Port when a link or switch fails or when STP
reconfigures itself. The Root Port transitions to the Forwarding state immediately without
going through the Listening and Learning states, as it would with the usual STP process.
UplinkFast also limits the burst of multicast traffic by reducing the max-update-rate, which
specifies the maximum rate (in packets per second) at which update packets are sent. For IOS
the default for this parameter is 150 packets per second.
UplinkFast is most useful in wiring closet switches at the edge of the network. It is inappro-
priate for backbone (core) devices. UplinkFast provides fast convergence after a direct link
failure and achieves load sharing between redundant links using uplink groups. An uplink
group is a set of interfaces (per VLAN), only one of which is forwarding at any given time.
Specifically, an uplink group consists of the Root Port (which is forwarding) and a set of
Blocked Ports.
The uplink group provides an alternative path in case the currently forwarding link fails.
Figure 3-23 shows a sample topology with no link failures and a Blocked Port on Switch C.

Figure 3-23 A Blocked Port Is in Effect When Physical Loops Are Present in a Network Running STP

Switch A
(Root) Switch B
L1

L2 L3

Blocked Port

Switch C

Switch A, the Root Switch, is connected directly to Switch B over link L1 and to Switch C
over link L2. The interface on Switch C that is connected directly to Switch B is in a Block-
ing state. Switch C is configured with UplinkFast.
If Switch C detects a link failure on the currently active link L2 on the Root Port (a direct link
failure), UplinkFast unblocks the Blocked Port on Switch C and transitions it to the Forward-
ing state without going through the Listening and Learning states, as illustrated in Figure 3-24.
1439_CCNP_3.book Page 182 Wednesday, October 27, 2004 9:54 AM

182 Chapter 3: Spanning Tree Protocol (STP)

Figure 3-24 UplinkFast Enables a Quick Transition to Forwarding State for an Alternate Uplink
Upon Primary Link Failure

Switch A
(Root) Switch B
L1

L2 L3

Link Failure

UplinkFast Transition Port


Directly to Forwarding State

Switch C

The change affected by UplinkFast takes approximately 1 to 5 seconds. As soon as a switch


transitions an alternative port to the Forwarding state, the switch begins transmitting dummy
multicast frames on that port, one for each entry in the local bridge table (except entries that
are associated with the failed Root Port). By default, approximately 15 dummy multicast
frames are transmitted per 100 milliseconds.
Each dummy multicast frame uses the station address in the bridge table entry as its source
MAC address and a dummy multicast address (01-00-0C-CD-CD-CD) as the destination
MAC address. Switches receiving these dummy multicast frames immediately update their
bridge table entries for each source MAC address to use the new port, allowing the switches
to begin using the new path almost immediately.
In the event that connectivity on the original Root Port is restored, the switch waits for a
period equal to twice the Forward Delay time plus 5 seconds before transitioning the port to
the Forwarding state to give the neighbor port time to transition through the Listening and
Learning states to the Forwarding state. Configuring UplinkFast on Catalyst switches is
straightforward, as you will see in the section “Configuring UplinkFast.”

BackboneFast
BackboneFast is a Catalyst feature that is initiated when a Root Port or Blocked Port on a
switch receives inferior BPDUs from its Designated Bridge. An inferior BPDU identifies
one switch as both the Root Switch and the Designated Bridge. When a switch receives an
1439_CCNP_3.book Page 183 Wednesday, October 27, 2004 9:54 AM

STP Enhancements 183

inferior BPDU, it means that a link to which the switch is not directly connected (an indirect
link) has failed. That is, the Designated Bridge has lost its connection to the Root Switch.
Under STP rules, the switch ignores inferior BPDUs for the configured Max Age (the default
is 20 seconds).
The role of BackboneFast is essentially to cheat this 20-second delay. When the switch
receives the inferior BPDU, the switch tries to determine if it has an alternative path to the
Root Switch.
There are two cases to consider:
■ If the inferior BPDU arrives on a Blocked Port, the Root Port and other Blocked Ports
on the switch become alternative paths to the Root Switch.
■ If the inferior BPDU arrives on the Root Port, all Blocked Ports become potential alter-
native paths to the Root Switch.
If the inferior BPDU arrives on the Root Port and there are no Blocked Ports, the switch
assumes that it has lost connectivity to the Root Switch, causing the Max Age on the root to
expire, and it becomes the Root Switch according to normal STP rules. If the switch has alter-
native paths to the Root Switch, it uses these alternative paths to transmit a new kind of proto-
col data unit (PDU) called the Root Link Query PDU. The switch sends the Root Link Query
PDU on all potential alternative paths to the Root Switch.
If the switch determines that it still has an alternative path to the root, it causes the Max Age
on the ports on which it received the inferior BPDU to expire. The switch then makes all
ports on which it received an inferior BPDU its Designated Ports and moves them out of the
Blocking state (if they were in the Blocking state), through the Listening and Learning states,
and into the Forwarding state. On the other hand, if the switch learns via the Root Link Query
process that all the alternative paths to the Root Switch have lost connectivity to the root, the
switch causes the Max Age on the ports on which it received inferior BPDUs to expire, and a
new STP topology is calculated. To illustrate this process, Figure 3-25 shows a sample topol-
ogy with no link failures. Switch A, the Root Switch, connects directly to Switch B over link
L1 and to Switch C over link L2. The interface on Switch C that connects directly to Switch B
is in the Blocking state.
1439_CCNP_3.book Page 184 Wednesday, October 27, 2004 9:54 AM

184 Chapter 3: Spanning Tree Protocol (STP)

Figure 3-25 A Converged Spanning-Tree Topology Is in Place

Switch A
(Root) Switch B
L1

L2 L3

Blocked Port

Switch C

If link L1 fails, Switch C cannot directly detect this failure, because it is not directly con-
nected to link L1. Switch B is directly connected to the Root Switch over L1, detects the fail-
ure, elects itself as the root, and begins sending BPDUs to Switch C. When Switch C receives
the inferior BPDUs from Switch B, Switch C assumes that an indirect failure has occurred. At
that point, BackboneFast allows the Blocked Port on Switch C to move immediately to the
Listening state without waiting for Max Age on the port to expire. BackboneFast then transi-
tions the interface on Switch C to the Forwarding state, providing a path from Switch B to
Switch A. This switchover takes approximately 30 seconds, twice the Forward Delay time if
the default Forward Delay time of 15 seconds is set. This saves up to 20 seconds. Figure 3-26
shows how BackboneFast reconfigures the topology to account for the failure of link L1.

Figure 3-26 BackboneFast Permits Rapid STP Reconvergence When a Remote Link Fails

Switch A
(Root) Switch B
L1

Link Failure

L2 L3

BackboneFast Transition Port


Through Listening and Learning
State to Forwarding State.

Switch C
1439_CCNP_3.book Page 185 Wednesday, October 27, 2004 9:54 AM

802.1w Rapid STP 185

The later section “Configuring BackboneFast” details the procedures for configuring this fea-
ture on a Catalyst switch.

802.1w Rapid STP


Rapid Spanning Tree Protocol (RSTP) IEEE 802.1w can be seen as more of an evolution
of the 802.1D standard than a revolution (see Figure 3-27). The 802.1D terminology remains
primarily the same, and most parameters have been left unchanged so that users familiar with
802.1D can rapidly configure the new protocol comfortably. In most cases, RSTP performs
better than Cisco’s proprietary extensions without any additional configuration. 802.1w also
can revert to 802.1D to interoperate with legacy bridges (thus, dropping the benefits it intro-
duces) on a per-port basis. This section briefly explains the enhancements RSTP adds to the
previous 802.1D standard.

Figure 3-27 Trying to Keep All the STPs and Their Features in Perspective Is Challenging

Cisco’s Spanning Tree Protocol Process IEEE Standard


Implementation
Spanning Tree ST = Spanning Tree RSTP:
Protocol (STP): • 802.1W
• 802.1D • Edge Port
• Common Spanning (Cisco PortFast)
Tree (CST) • UplinkFast RSTP
• Mono Spanning ST (Cisco UplinkFast)
Tree (MST) • BackboneFast Engine
Cisco Enhancements (Cisco BackboneFast)
(First Evolution):
• PortFast
• UplinkFast VLAN 1 VLAN 2 VLAN 3
• BackboneFast

Cisco Enhancements
(Second Evolution):
• PVST: ISL
• PVST+: ISL & 802.1Q
ST ST ST
• Includes previous
Enhancements
• Additional
Enhancements: VLAN 1 VLAN 2 VLAN 3
• BPDU Guard
• Root Guard
Cisco MISTP: Multiple Spanning
ST ST
• Uses PVST+ Tree (MSTP):
• Includes previous • 802.1s
Enhancements • Uses RSTP
• Catalyst 4000/6000
VLAN 1 VLAN 2 VLAN 3
1439_CCNP_3.book Page 186 Wednesday, October 27, 2004 9:54 AM

186 Chapter 3: Spanning Tree Protocol (STP)

RSTP States
802.1D defined five different port states:
■ Disabled
■ Listening
■ Learning
■ Blocking
■ Forwarding
Table 3-5 compares the 802.1D STP states with the 802.12 RSTP states.

Table 3-5 IEEE 802.1w Has Three Port States Versus the Five Port States Used in IEEE 802.1D

Is the Port Included Is the Port


RSTP (802.1w) in the Active Learning MAC
STP (802.1D) Port State Port State Topology? Addresses?

Disabled Discarding No No

Blocking Discarding No No

Listening Discarding No No

Learning Learning No Yes

Forwarding Forwarding Yes Yes

IEEE 802.1D STP was a bit confusing in that it mixed a port’s state (whether it blocks or for-
wards traffic) and the role it plays in the active topology (Root Port, Designated Port, and so
on). For example, from an operational point of view, there is no difference between a port in
Blocking state and a port in Listening state. They both discard frames and do not learn MAC
addresses. The real difference lies in the role the spanning tree assigns to the port. It can be
safely assumed that a port in Listening state is either Designated or Root and is on its way to
the Forwarding state. Unfortunately, once in Forwarding state, there is no way to infer from
the port state whether the port is Root or Designated, which demonstrates the weakness of
this state-based terminology. RSTP addresses this by decoupling a port’s role and state.
Only three port states in RSTP correspond to the three possible operational states. The 802.1D
states Disabled, Blocking, and Listening have been merged into a unique 802.1w Discarding
state, as shown in Table 3-5.
Rapid transition to Forwarding state is the most important feature introduced by 802.1w. The
legacy Spanning Tree Algorithm passively waited for the network to converge before turning
1439_CCNP_3.book Page 187 Wednesday, October 27, 2004 9:54 AM

802.1w Rapid STP 187

a port into the Forwarding state. Achieving faster convergence was a matter of tuning the
conservative default parameters (Forward Delay and Max Age timers), often putting the net-
work’s stability at stake. RSTP can actively confirm that a port can safely transition to the
Forwarding state without relying on any timer configuration. RSTP provides a real feedback
mechanism that takes place between RSTP-compliant bridges. To achieve fast convergence
on a port, the protocol relies on two new variables—edge ports and link type.
The edge port concept is already well known to the Cisco implementation of STP, because it
basically corresponds to the PortFast feature. All ports directly connected to end stations can-
not create bridging loops in the network and, thus, can directly transition to the Forwarding
state, skipping the Listening and Learning states. Neither edge ports nor PortFast-enabled
ports generate topology changes when the link toggles. Unlike PortFast, an edge port that
receives a BPDU immediately loses its edge port status and becomes a normal spanning-tree
port. At this point, the edge port state has a user-configured value and an operational value.
Cisco implementation maintains the portfast keyword to be used for edge port configuration,
thus making the transition to RSTP simpler.
RSTP link type, point-to-point or shared, can achieve rapid transition to the Forwarding state
only on edge ports and on point-to-point links. The link type is automatically derived from a
port’s duplex mode. A port operating in full duplex is assumed to be point-to-point, whereas
a half-duplex port is considered a shared port by default. This automatic link type setting can
be overridden by explicit configuration. In today’s switched networks, most links operate in
full-duplex mode and, therefore, are treated as point-to-point links by RSTP. This makes
them candidates for rapid transition to the Forwarding state.

RSTP Port Roles


The RSTP role is now a variable assigned to a given port. The Root Port and Designated Port
roles remain, but the Blocking Port role is now split into backup and Alternate Port roles. The
Spanning Tree Algorithm determines a port’s role based on BPDUs. To keep things simple,
the thing to remember about a BPDU is that there is always a way to compare any two of
them and to decide whether one is more useful than the other. This is based on the values
stored in the BPDU and occasionally on the port on which they are received. This considered,
the following paragraphs explain practical approaches to port roles.
As in standard STP, the port receiving the best BPDU on a bridge is the Root Port. This is the
port that is the closest to the Root Bridge in terms of Path Cost, as shown in Figure 3-28.
1439_CCNP_3.book Page 188 Wednesday, October 27, 2004 9:54 AM

188 Chapter 3: Spanning Tree Protocol (STP)

Figure 3-28 RSTP Also Uses Root Ports

Root
R Root Port

R R
A B

If a port can send the best BPDU on the segment to which it is connected, the port is consid-
ered a Designated Port (see Figure 3-29). As with 802.1D, bridges create a bridged domain
by linking different segments. A given segment can have only one path to the Root Switch.
Multiple paths would create a bridging loop in the network.

Figure 3-29 RSTP Uses Designated Ports as Well

Root
D Designated Port
D D

R R
A B
D

Alternate Port and Backup Port roles correspond to the Blocking state of 802.1D. A Blocked
Port is defined as not being the Designated or Root Port. A Blocked Port receives a more use-
ful BPDU than the one it would send out on its segment. Remember that a port absolutely
needs to receive BPDUs to stay blocked. RSTP introduces these two roles for this purpose.
An Alternate Port is a port blocked by receiving more useful BPDUs from another bridge, as
shown in Figure 3-30.
1439_CCNP_3.book Page 189 Wednesday, October 27, 2004 9:54 AM

802.1w Rapid STP 189

Figure 3-30 An Alternate Port Is a Port Blocked by Receiving More Useful BPDUs from
Another Bridge

Root
Alternate Port D D

R R
A B
D

A Backup Port is a port blocked by receiving more useful BPDUs from the same bridge it is
on, as shown in Figure 3-31.

Figure 3-31 A Backup Port Is a Port Blocked by Receiving More Useful BPDUs from the
Same Bridge

Root
Backup Port D D

R R
A B
D

This Backup Port distinction was already made internally within 802.1D and is essentially
how Cisco UplinkFast functions. The rationale behind 802.1w is that an Alternate Port pro-
vides an alternate path to the Root Bridge and, therefore, could replace the Root Port should it
fail. A Backup Port provides redundant connectivity to the same segment and cannot guarantee
alternate connectivity to the Root Switch. Therefore it was excluded from the uplink group.
1439_CCNP_3.book Page 190 Wednesday, October 27, 2004 9:54 AM

190 Chapter 3: Spanning Tree Protocol (STP)

RSTP calculates the final topology for the spanning tree using exactly the same criteria as
802.1D. There is absolutely no change in how the different bridge and port priorities are used.
The term Blocking is used for the Discarding state in Cisco implementation. With RSTP,
there is a difference between the role the protocol has determined for a port and its current
state. For example, with RSTP it is perfectly valid for a port to be both a Designated Port and
a Blocking Port at the same time. Although this typically happens for very short periods of
time, it simply means that this port is in a transitory state toward designated forwarding.

RSTP Timers
When the Spanning Tree Algorithm selects a port to become a Designated Port, 802.1D still
waits twice the Forward Delay number of seconds (2 * 15 seconds by default) before transi-
tioning it to the Forwarding state. In RSTP, this condition corresponds to a port with a desig-
nated role but a Blocking state. Figures 3-32 to 3-36 illustrate how fast transition is achieved
step by step. If a new link is created between the root and Switch A, both ports on the link are
put in a Discarding state until they receive a BPDU from their counterpart.
When a Designated Port is in Discarding or Learning state, and only in this case, it sets the
proposal bit on the BPDUs it sends out. This is what happens for port p0 of the Root Switch,
as shown in Step 1 of Figure 3-32. Because Switch A receives superior information, it imme-
diately knows that p1 will be its new Root Port. Switch A then starts a sync to ensure that all
its ports are in sync with this new information.

Figure 3-32 RSTP Uses a Sync Mechanism That Does Not Depend on Timers

Root
p0
3. Agreement, 1. Proposal
p1 Forwarding

p1 p0: Designated Port


p1: New Root Port
p2: Alternate Port
A p3: Designated Port
p2 p3 p4 p4: Edge Port

2. Sync (Block)
2. Sync 2. Sync
(Unchanged) (Unchanged)

A port is in sync if it meets either of the following criteria:


■ It is in a Blocking state (which means Discarding in a stable topology)
■ It is an edge port
1439_CCNP_3.book Page 191 Wednesday, October 27, 2004 9:54 AM

802.1w Rapid STP 191

To illustrate the effect of the sync mechanism on different kinds of ports, suppose there exists
an Alternate Port p2, a designated forwarding port p3, and an edge port p4 on Switch A, as
illustrated in Figure 3-32. Notice that p2 and p4 already meet one of the criteria just listed. To
be in sync, Switch A needs to block port p3, assigning it the Discarding state. Now that all of
its ports are in sync, Switch A can unblock its newly selected Root Port p1, and reply to the
root by sending an agreement message. This message is a copy of the proposal BPDU, with
the agreement bit set instead of the proposal bit. This ensures that port p0 knows exactly to
which proposal the agreement it receives corresponds.
After p0 receives that agreement, it can immediately transition to the Forwarding state, as
shown in Figure 3-33. Notice that port p3 was left in a designated Discarding state after the
sync. In Step 4, that port is in the same situation as was port p0 during Step 1 (in Figure 3-32). It
then starts proposing to its neighbor, attempting to quickly transition to forwarding.

Figure 3-33 p0 Immediately Transitions to Forwarding

Root
p0

4. go forwarding

p1

A
p2 p3 p4

4. proposal

The proposal agreement mechanism is very fast, because it does not rely on any timers. This
wave of handshakes propagates quickly toward the edge of the network and quickly restores
connectivity after a change in the topology.
If a designated discarding port does not receive an agreement after having sent a proposal, it
falls back to the traditional 802.1D Listening-Learning sequence. This could happen if the
remote bridge does not understand RSTP BPDUs or if the remote bridge port is blocking, as
with Switch C in Figure 3-34.
UplinkFast RSTP incorporates an automatically enabled feature similar to the Cisco UplinkFast
proprietary STP extension. The 802.1w topology change mechanism clears the appropriate
entries in the Content Addressable Memory (CAM) tables of the upstream bridges, removing
the need for UplinkFast’s dummy multicast generation process.
1439_CCNP_3.book Page 192 Wednesday, October 27, 2004 9:54 AM

192 Chapter 3: Spanning Tree Protocol (STP)

Figure 3-34 If a Remote Bridge Does Not Support RSTP, the Sync Mechanism Will Not Work, and
the Switches Resort to Traditional 802.1D STP

Root

2
3

B C D

When an 802.1D bridge detects a topology change, it first notifies the Root Bridge using a
reliable mechanism, as shown in Figure 3-35. As soon as the Root Bridge is aware of a change
in the network topology, it sets the TC flag on the BPDUs it sends out, which are then relayed
to all the bridges in the network. When a bridge receives a BPDU with the TC flag bit set, it
reduces its bridging table aging time to forward delay seconds, ensuring a relatively quick
flushing of stale information.

Figure 3-35 An 802.1D Bridge Reacts to a Topology Change by Notifying the Root Switch with a
Reliable Mechanism

Root Root

This topology change mechanism has been deeply remodeled in RSTP. Both the detection of
a topology change and propagation through the network have evolved.
1439_CCNP_3.book Page 193 Wednesday, October 27, 2004 9:54 AM

802.1w Rapid STP 193

In RSTP, only non-edge ports moving to the Forwarding state cause a topology change. This
means that a loss of connectivity is not considered a topology change, contrary to 802.1D
(that is, a port moving to blocking no longer generates a TC).
When a RSTP bridge detects a topology change, the following happens:
■ The RSTP bridge starts the TC While timer with a value equal to twice the Hello Time
for all its non-edge Designated Ports and its Root Port if necessary.
■ The RSTP bridge flushes the MAC addresses associated with all of these ports.
■ As long as the TC While timer is running on a port, the BPDUs sent out that port have
the TC bit set. BPDUs are also sent on the Root Port while the timer is active.
Topology change propagation with RSTP is handled differently with RSTP. When a bridge
receives a BPDU from a neighbor with the TC bit set, the following happens:
■ The bridge clears the MAC addresses learned on all of its ports except the one that
received the topology change.
■ The bridge starts the TC While timer and sends BPDUs with the TC set on all of its
Designated Ports and Root Port. (RSTP no longer uses the specific TCN BPDU
unless a legacy bridge needs to be notified.)
This way, the TCN is flooded very quickly across the whole network, as shown in Figure 3-36.

Figure 3-36 The Initiator of the Topology Change Floods the Information Throughout the Network

Root

TC

With RSTP, the TC propagation is a one-step process. In fact, the initiator of the topology
change floods this information throughout the network (as opposed to 802.1D, where only the
root could do so). This mechanism is much faster than the 802.1D equivalent. There is no
need to wait for the Root Bridge to be notified and then maintain the topology change state
for the whole network for Max Age plus Forward Delay seconds. In just a few seconds (a
1439_CCNP_3.book Page 194 Wednesday, October 27, 2004 9:54 AM

194 Chapter 3: Spanning Tree Protocol (STP)

small multiple of Hello Time), most of the entries in the CAM tables of the entire network
(VLAN) are flushed. This approach results in potentially more temporary flooding, but on the
other hand, it clears potential stale information that prevents rapid connectivity restitution.
RSTP is fully compatible with and capable of interoperating with legacy (802.1D) STP proto-
cols. However, it is important to note that 802.1w inherent fast convergence benefits are lost
when interacting with legacy bridges.

RSTP BPDU Format


RSTP has introduced a few changes to the BPDU format. Only two flags, Topology Change
(TC) and TC Acknowledgment (TCA), were defined in 802.1D. As shown in Figure 3-37,
RSTP uses all 6 remaining bits of the flag byte to do the following:
■ Encode the role and state of the port originating the BPDU
■ Handle the proposal/agreement mechanism

Figure 3-37 The RSTP BPDU Uses All the Bits in the Flag Byte

0 1 2 3 4 5 6 7
Topology Proposal Portrole Learning Forwarding Agreement Topology
Change Change ACK

00 Unknown
01 Alternate/Backup
10 Root
11 Designated

Another important change is that the RSTP BPDU is of type 2, version 2. The implication is
that legacy bridges must drop this new BPDU. This property makes it easy for an 802.1w
bridge to detect legacy bridges connected to it.
BPDUs are sent every Hello Time (not simply relayed, as with 802.1D). With 802.1D, a
non-Root Switch generated BPDUs only when it received one on its Root Port. In fact, with
802.1D, a bridge relays BPDUs more than actually generating them. This is not the case
with 802.1w, where a bridge sends a BPDU with its current information every Hello Time
seconds (2 by default), even if it does not receive any BPDUs from the Root Bridge.
On a given port, if hellos are not received for three consecutive times (or if Max Age expires),
protocol information can be immediately aged out. Because of the previously mentioned pro-
tocol modification, BPDUs are now used as a keepalive mechanism between bridges. A
bridge decides it has lost connectivity to its direct neighboring root or designated bridge if it
1439_CCNP_3.book Page 195 Wednesday, October 27, 2004 9:54 AM

Evolution of Spanning Tree 195

misses three BPDUs in a row. This fast aging of the information allows quick failure detec-
tion. If a bridge fails to receive BPDUs from a neighbor, it is certain that the connection to
that neighbor has been lost, as opposed to 802.1D, where the problem could be anywhere on
the path to the root. Note that with RSTP, failures are detected much faster in case of physical
link failures than with 802.1D.
The concept of accepting inferior BPDUs is what makes up the core of the BackboneFast
engine. The IEEE 802.1w committee decided to incorporate a similar mechanism into RSTP.
When a bridge receives inferior information from its Designated or Root Switch, it immedi-
ately accepts it and replaces the one previously stored.
In Figure 3-38, Bridge C still knows the root is alive and well and immediately sends a BPDU
to Bridge B containing information about the Root Switch. As a result, Bridge B stops send-
ing its own BPDUs and accepts the port leading to Bridge C as its new Root Port.

Figure 3-38 Bridge B Stops Sending Its Own BPDUs and Accepts the Port Leading to Bridge C as Its
New Root Port

B
Root
Inferior BPDU
“I Am the Root”

Evolution of Spanning Tree


Several options are now available with STP on Catalyst switches, as described in this section.
PVST+ is still the default setting on Catalyst switches, but RSTP and MST are now viable
alternatives. The legacy 802.1D implementations of spanning tree are also described here.

PVST (Per-VLAN Spanning Tree), PVST+, and Mono Spanning


Tree Modes
Common Spanning Tree (CST) is specified in the IEEE 802.1Q standard. CST defines a
single instance of spanning tree for all VLANs. BPDUs are transmitted over VLAN 1.
Per-VLAN Spanning Tree (PVST) is a Cisco-proprietary implementation requiring Interlink
1439_CCNP_3.book Page 196 Wednesday, October 27, 2004 9:54 AM

196 Chapter 3: Spanning Tree Protocol (STP)

Switch (ISL) trunk encapsulation. PVST runs a separate instance of STP for each VLAN.
Among other things, this lets you configure distinct Root Switches for each VLAN and con-
figure Layer 2 load sharing, as shown in Figure 3-39.

Figure 3-39 PVST Enables Layer 2 Load Sharing by Running a Separate Instance of Spanning Tree
for Each VLAN

VLAN 1
Root Switch

VLAN 2
Root Switch

VLAN 1
Spanning
Tree
VLAN 2
Spanning
Tree

Having a separate spanning tree instance for each VLAN reduces the recovery time for STP
recalculation and, hence, increases network reliability in the following ways:
■ It reduces the overall size of the spanning-tree topology.
■ It improves scalability and decreases convergence time.
■ It provides faster recovery and better reliability.
Disadvantages of a spanning tree for each VLAN include the following:
■ Use of switches (such as CPU load) to support spanning tree maintenance for multiple
VLANs
■ Use of bandwidth on trunk links to support BPDUs for each VLAN
PVST+ is a Cisco-proprietary STP mode that allows CST and PVST to exist on the same
network.
1439_CCNP_3.book Page 197 Wednesday, October 27, 2004 9:54 AM

Evolution of Spanning Tree 197

PVST+ supports 802.1Q trunks and the mapping of multiple spanning trees to the single span-
ning tree of non-Cisco 802.1Q switches. PVST+ is automatically enabled on Catalyst 802.1Q
trunks. It runs one instance of STP per VLAN when Catalyst switches are connected by
802.1Q trunks. PVST+ is the default STP used on all Ethernet, Fast Ethernet, and Gigabit
Ethernet port-based VLANs on the Catalyst 4000 and 6000 family of switches. PVST+ runs
on each VLAN on the switch, ensuring that each has a loop-free path through the network.
PVST+ provides Layer 2 load sharing for the VLAN on which it runs. Different logical topol-
ogies can be created using the VLANs on a network to ensure that all links are used, but no
single link is oversubscribed.
Each instance of spanning tree has a single Root Switch. This Root Switch propagates the
spanning tree information associated with that VLAN to all other switches in the network.
Because each switch has the same knowledge about the network, this process ensures that the
network topology is maintained.
The PVST+ architecture distinguishes three types of zones or regions:
■ A PVST zone or region
■ A PVST+ zone or region
■ A mono spanning tree zone or region
Mono Spanning Tree (MST) is the spanning tree implementation used by non-Cisco 802.1Q
switches. One instance of STP is responsible for all VLAN traffic. Each zone or region con-
sists of a homogenous type of switch. Connecting two ISL ports can connect a PVST region
to a PVST+ region. Similarly, connecting two 802.1Q ports can connect a PVST+ region to an
MST region. Note that an MST and PVST region cannot be connected via a trunk link. Although
it is possible to provide a nontrunk connection between the two regions by using an access
link, this is of limited use in real-world networks. Figure 3-40 illustrates the three types of
STP regions and how they are linked.
At the boundary between a PVST region and a PVST+ region, the mapping of spanning trees
is one-to-one. At the boundary between an MST region and a PVST+ region, the spanning
tree in the MST region maps to one PVST in the PVST+ region. The one it maps to is the
CST. The default CST is VLAN 1.
All PVSTs, except the CST, are tunneled through the MST region. Tunneling means that
BPDUs are flooded through the MST region along the single spanning tree that is present in
the MST region. Do not confuse this use of the term tunnel with the point-to-point tunnels
configured on Cisco routers and PIX firewalls. In general, a tunnel refers to a mechanism that
enables the propagation of packets or frames through a series of devices in such a way that
the contents of the packets or frames are not changed in transit.
1439_CCNP_3.book Page 198 Wednesday, October 27, 2004 9:54 AM

198 Chapter 3: Spanning Tree Protocol (STP)

Figure 3-40 PVST+ Allows for Interoperation Between PVST Switches and Non-Cisco 802.1Q Mono
Spanning Tree Switches

PVST+ Backbone
Cisco Devices

ISL Trunk 802.1Q Trunk

PVST Zone MST Zone


Cisco Devices Non-Cisco Devices

Enhanced PVST+
Enhanced PVST+ permits interoperability between PVST+ and MST. MISTP mode is a
Cisco-proprietary implementation of MST on some Catalyst switches. MISTP-PVST+ allows
the use of MISTP functionality of the Catalyst 4000 and 6000 series switches while continuing
to communicate with the older Catalyst switches in the network that use PVST+. The MISTP
options are implemented under Catalyst OS (CatOS).

MISTP Mode
After the development of PVST+, someone got the idea that it would be useful to have an
STP mode that allows for a compromise between PVST+ and MST. Multiple Instances of
Spanning Tree Protocol (MISTP) lets you group multiple VLANs under a single instance
of spanning tree. MISTP combines the Layer 2 load-balancing benefits of PVST+ with the
lower CPU load of IEEE 802.1Q.
MISTP is an optional STP mode that runs on the Catalyst 4000 and 6000 switch families.
A MISTP instance is a virtual logical topology defined by a set of bridge and port parameters.
An MISTP instance becomes a real topology when VLANs are mapped to it. Each MISTP
instance has its own Root Switch and a different set of forwarding links (that is, different bridge
and port parameters). This Root Switch propagates the information associated with that
instance of MISTP to all other switches in the network. This process ensures that the network
topology is maintained, because each switch has the same knowledge about the network.
1439_CCNP_3.book Page 199 Wednesday, October 27, 2004 9:54 AM

Evolution of Spanning Tree 199

MISTP builds MISTP instances by exchanging MISTP BPDUs with peer entities in the net-
work. There is only one BPDU for each MISTP instance, rather than for each VLAN as in
PVST+. There are fewer BPDUs in a MISTP network, so there is less overhead in the net-
work. MISTP discards any PVST+ BPDUs it sees.
A MISTP instance can have any number of VLANs mapped to it, but a VLAN can be mapped
to only a single MISTP instance. VLANs can be easily moved in a MISTP topology to
another MISTP instance if they have converged. However, if ports are added at the same time
the VLAN is moved, additional convergence time is required.

MISTP-PVST+ Mode
MISTP-PVST+ is a transition STP mode that allows the use of MISTP functionality of the
Catalyst 4000 and 6000 series switches while continuing to communicate with the older
Catalyst switches in the network that use PVST+. A switch using PVST+ mode and a switch
using MISTP mode that are connected cannot see the BPDUs of the other switch, a condition
that can cause loops in the network. MISTP-PVST+ allows interoperability between PVST+
and MISTP, because it detects the BPDUs of both modes. To convert a network to MISTP,
MISTP-PVST+ can be used to transition the network from PVST+ to MISTP to avoid prob-
lems. MISTP-PVST+ conforms to the limits of PVST+.

MST (802.1s)
The acronym MST stands for two things:
■ Mono Spanning Tree
■ Multiple Spanning Tree
Be careful to differentiate between the two in context. The Multiple Spanning Tree feature
was originally released for Catalyst 4000 and 6000 series switches. MST is specified in IEEE
802.1s, an amendment to IEEE 802.1Q. MST extends the IEEE 802.1w Rapid Spanning Tree
(RST) Algorithm to multiple spanning trees, as opposed to the single CST of the original
IEEE 802.1Q specification.
This extension provides for both rapid convergence and load sharing in a VLAN environ-
ment. Cisco implementation of MST is backward-compatible with 802.1D STP, the 802.1w
RSTP, and the Cisco PVST+ architecture. MST can be thought of as a standards-based
MISTP. The IEEE 802.1w specification, RSTP, provides for subsecond reconvergence of STP
after failure of one of the uplinks in a bridged environment. 802.1w provides the structure on
which the 802.1s feature operates.
1439_CCNP_3.book Page 200 Wednesday, October 27, 2004 9:54 AM

200 Chapter 3: Spanning Tree Protocol (STP)

Table 3-6 describes support for MST on Cisco switches.

Table 3-6 MST Is Supported on All New Catalyst Switches

Catalyst Platform MST with RSTP Support

Catalyst 2900 XL and 3500 XL Unavailable

Catalyst 2950 and Catalyst 3550 Cisco IOS Release 12.1(9)EA1

Catalyst 2955 All Cisco IOS software releases

Catalyst 2948G-L3 and Catalyst Unavailable


4908G-L3

Catalyst 4000, Catalyst 2948G, and Catalyst OS version 7.1


Catalyst 2980G (Catalyst OS)

Catalyst 4000 and Catalyst 4500 Cisco IOS Release 12.1(12c)EW


(Cisco IOS)

Catalyst 5000 and Catalyst 5500 Unavailable

Catalyst 6000 and Catalyst 6500 Catalyst OS version 7.1


(Catalyst OS)

Catalyst 6000 and Catalyst 6500 Cisco IOS Releases 12.1(11b)EX, 12.1(13)E, and
(Cisco IOS) 12.2(14)SX

Catalyst 8500 Unavailable

The IEEE 802.1s Multiple Spanning Tree specification allows a user to build multiple spanning
trees over VLAN trunks. Fast convergence of the MST topology is achieved using a modified
version of the RSTP protocol. VLANs can be grouped and associated to spanning-tree instances.
Each instance can have a topology independent of other spanning-tree instances. This new
architecture provides multiple forwarding paths for data traffic and enables load sharing.
Network fault tolerance is improved, because a failure in one instance does not affect other
instances.
In large networks, having different VLAN spanning-tree instance assignments located in dif-
ferent parts of the network makes it easier to administer and use redundant paths. However, a
spanning-tree instance can exist only on bridges that have compatible VLAN instance assign-
ments. Therefore, MST requires the configuration of a set of bridges with the same MST con-
figuration information, allowing them to participate in a given set of spanning-tree instances.
Interconnected bridges that have the same MST configuration are called MST regions. MST,
like MISTP (see Figure 3-41), provides interoperability with PVST+ regions.
1439_CCNP_3.book Page 201 Wednesday, October 27, 2004 9:54 AM

Evolution of Spanning Tree 201

Figure 3-41 MISTP Is a Cisco-Proprietary Implementation of MST

PVST +
Layer 2 Load Balancing

MST (802.1Q)
Group Multiple VLANs in One
Instance of Spanning Tree

MISTP
Load Balancing +
Lower CPU Utilization

Load Sharing
Load sharing can be accomplished using a couple of different methods. The most common
method of load sharing is through Root Bridge placement on a per-VLAN basis. This distrib-
utes traffic for separate VLANs across separate paths to different Root Switches. A separate
method divides the bandwidth supplied by parallel trunks connecting switches. To avoid
loops, STP normally blocks all but one parallel link between switches.
Using load sharing, traffic can be divided between the links according to which VLAN the
traffic belongs to.
Load sharing can be configured on trunk ports using one of the following methods:
■ STP port priorities—Both load-sharing links must be connected to the same switch.
■ STP path costs—Each load-sharing link can be connected to the same switch or to two
different switches.
The following sections examine each of these methods in greater detail. For detailed configu-
ration information, consult the “Configuring Load Sharing” section later in this chapter.

Load Sharing Using STP Port Priorities


When two ports on the same switch form a loop, the STP Port Priority setting determines
which port is enabled and which port is in a blocking state. The priorities on a parallel trunk
port can be set so that the port carries all the traffic for a given VLAN. The trunk port with the
1439_CCNP_3.book Page 202 Wednesday, October 27, 2004 9:54 AM

202 Chapter 3: Spanning Tree Protocol (STP)

higher priority (lower values) for a VLAN forwards traffic for that VLAN. The trunk port
with the lower priority (higher values) for the same VLAN remains in a Blocking state for
that VLAN. One trunk port sends or receives all traffic for the VLAN.
Figure 3-42 shows two trunks connecting supported switches configured as follows:
■ VLANs 8 to 10 are assigned a Port Priority of 10 on Trunk 1.
■ VLANs 3 to 6 retain the default Port Priority of 128 on Trunk 1.
■ VLANs 3 to 6 are assigned a Port Priority of 10 on Trunk 2.
■ VLANs 8 to 10 retain the default Port Priority of 128 on Trunk 2.

Figure 3-42 Port Priorities Can Be Used to Affect STP Load Sharing

Switch 1

Trunk 1 Trunk 2
VLANs 8 to 10 (Priority 10) VLANs 3 to 6 (Priority 10)
VLANs 3 to 6 (Priority 128) VLANs 8 to 10 (Priority 128)

Switch 2

In the configuration shown in Figure 3-42, Trunk 1 carries traffic for VLANs 8 to 10, and
Trunk 2 carries traffic for VLANs 3 to 6. If the active trunk fails, the trunk with the lower pri-
ority takes over and carries the traffic for all the VLANs. No duplication of traffic occurs over
any trunk port.

Load Sharing Using STP Path Cost


Parallel trunks can be configured to share VLAN traffic by setting different Path Costs on a
trunk and associating them with different sets of VLANs. The VLANs keep the traffic sepa-
rate. Because no loops exist, STP does not disable the ports, and redundancy is maintained in
the event of a lost link.
Figure 3-43 shows that trunk ports 1 and 2 are 100BASE-T ports. The Path Costs for the
VLANs are assigned as follows:
■ VLANs 2 to 4 are assigned a Path Cost of 30 on Trunk Port 1.
■ VLANs 8 to 10 retain the default 100BASE-T Path Cost of 19 on Trunk Port 1.
■ VLANs 8 to 10 are assigned a Path Cost of 30 on Trunk Port 2.
■ VLANs 2 to 4 retain the default 100BASE-T Path Cost of 19 on Trunk Port 2.
1439_CCNP_3.book Page 203 Wednesday, October 27, 2004 9:54 AM

Evolution of Spanning Tree 203

Figure 3-43 Path Costs Can Be Used to Affect STP Load Sharing

Switch 1

Trunk Port 1 Trunk Port 2


VLANs 2 to 4 (Path Cost 30) VLANs 8 to 10 (Path Cost 30)
VLANs 8 to 10 (Path Cost 19) VLANs 2 to 4 (Path Cost 19)

Switch 2

In the configuration shown in Figure 3-43, Trunk 1 carries traffic for VLANs 8 to 10, and
Trunk 2 carries traffic for VLANs 2 to 4. If the active trunk fails, the trunk with the higher
Path Cost takes over and carries the traffic for all the VLANs. No duplication of traffic occurs
over any trunk port.

Switchport Tuning Using BPDU Guard


STP configures a meshed topology into a loop-free, tree-like topology. When the link on a
bridge port goes up, STP calculation is done on that port. The result of the calculation is the
transition of the port into the Forwarding or Blocking state, depending on the port’s position
in the network and the STP parameters. This calculation and transition period usually takes
about 30 to 50 seconds. At this time, no user data passes via the port. Some user applications
might time out during this period.
To allow immediate transition of the port into the Forwarding state, the STP PortFast feature
is enabled. PortFast transitions the port into the STP Forwarding state immediately upon
linkup. The port still participates in STP in the event that the port is to be a part of a loop; if
so, the port eventually transitions into STP blocking mode.
As long as the port is participating in STP, there is a possibility that some device attached to
that port and also running STP with a lower Bridge Priority than that of the current Root
Switch will assume the Root Bridge function and affect active STP topology, thus rendering
the network suboptimal. Permanent STP recalculation caused by the temporary introduction
and subsequent removal of STP devices with low (0) Bridge Priority represents a simple form
of Denial of Service (DoS) attack on the network.
The STP PortFast BPDU guard enhancement is designed to allow network designers to
enforce the STP domain borders and keep the active topology predictable. The devices
behind the ports with STP PortFast enabled are not allowed to influence the STP topology.
This is achieved by disabling the port with PortFast configured upon receipt of BPDU. The
1439_CCNP_3.book Page 204 Wednesday, October 27, 2004 9:54 AM

204 Chapter 3: Spanning Tree Protocol (STP)

port is transitioned into Errdisable state, and a message appears on the console. The following
is an example of the message that appears as a result of BPDU guard operation:
2000 May 12 15:13:32 %SPANTREE-2-RX_PORTFAST:Received BPDU on PortFast enable
port. Disabling 2/1
2000 May 12 15:13:32 %PAGP-5-PORTFROMSTP:Port 2/1 left bridge port 2/1

On the left side of Figure 3-44, Bridge A has priority 8192 and is the root for the VLAN.
Bridge B has priority 16384 and is the backup Root Switch for the same VLAN. Bridges A
and B, connected by a Gigabit Ethernet link, make up the network core. Bridge C is an access
switch and has PortFast configured on the port connected to Device D. Given that the other
STP parameters are the default, the Bridge C port that connects to Bridge B is in STP Block-
ing state. Device D (a PC) is not participating in STP. The red arrows indicate the flow of STP
BPDUs.

Figure 3-44 BPDU Guard Prevents Rogue Devices from Affecting the STP Topology

1) 2)
A B A B

C C

D D

Now, suppose that Device D starts participating in STP (for example, if a Linux-based bridge
application were launched on a PC), as shown on the right side of Figure 3-44. If the software
bridge’s priority is 0 or any value below that of the Root Switch, the software bridge takes
over the Root Bridge function (as the bridge with the lowest priority). The Gigabit link con-
necting the two core switches transitions into blocking mode, causing all the data in that
particular VLAN to flow via the 100-Mbps link. If more data is flowing via the core in the
VLAN than the link can accommodate, dropping of frames occurs, leading to a connectivity
outage. The STP PortFast BPDU guard feature would prevent such a situation by disabling
the port as soon as an STP BPDU is received from Device D.
1439_CCNP_3.book Page 205 Wednesday, October 27, 2004 9:54 AM

Evolution of Spanning Tree 205

Switchport Tuning Using Root Guard


Traditional 802.1D STP does not provide any means for the network administrator to securely NOTE
enforce the switched Layer 2 network topology. This might become especially important in Even if the administra-
tor sets the Root Bridge
networks with shared administrative control (for example, one switched network controlled
Priority to 0 in an effort
by different administrative entities or companies). to secure the Root Bridge
position, there is still
The switched network’s forwarding topology is calculated based on, among other parameters, no guarantee, because
the Root Switch position. Although any switch can be the Root Switch in the network, it is there might be a bridge
with priority 0 and a
better to place the Root Bridge manually (somewhere in the core layer) so that the forwarding lower BID. The Root
topology is optimal. The standard 802.1D STP does not allow the administrator to enforce the Guard feature is
Root Switch’s position. If a bridge is introduced into the network with a lower Bridge Priority, it designed to provide a
way to enforce the Root
takes the role of the Root Bridge. Switch placement in the
network.
The root guard ensures that the port on which root guard is enabled is the Designated Port.
(Normally, Root Bridge ports are all designated unless two or more ports of the Root Bridge
are connected.) If the bridge receives superior STP BPDUs on a root guard-enabled port, this
port is moved to a root-inconsistent STP state (effectively equal to the Listening state), and no
traffic is forwarded across this port. The position of the Root Switch is enforced, as shown in
Figure 3-45.

Figure 3-45 The Root Guard Feature Enforces the Placement of the Root Switch in a Network

Root Bridge A B

Consider an example of why a rogue Root Bridge can cause problems on the network and
how root guard can help:
■ Switches A and B comprise the core of the network, and Switch A is the Root Switch
for a VLAN.
■ Switch C is an access layer switch.
■ The link between Switches B and C is blocking on the C side. The flow of STP BPDUs
is shown with arrows.
1439_CCNP_3.book Page 206 Wednesday, October 27, 2004 9:54 AM

206 Chapter 3: Spanning Tree Protocol (STP)

In Figure 3-46, Device D begins to participate in STP. If the priority of Bridge D is 0 or any
value lower than that of the Root Switch, the software bridge is elected as a Root Switch for
this VLAN. In turn, the Gigabit link connecting the two core switches blocks, causing all the
data in that particular VLAN to flow via a 100-Mbps link across the access layer. If more data
is flowing via the core in that VLAN than this link can accommodate, some frames are
dropped, causing performance loss or a connectivity outage.

Figure 3-46 Root Guard Prevents Device D from Becoming the Root Switch

A B

New Root

The root guard feature is designed to protect the network from such issues. Root guard is
configured on a per-port basis and does not allow the port to become an STP Root Port. This
means that the port is always STP-designated. If a better BPDU is received on this port,
BPDU guard disables the port rather than taking the BPDU into account and electing a new
STP root.
Root guard needs to be enabled on all ports where the Root Switch should not appear. In
Figure 3-46, root guard should be enabled as follows:
■ Switch A: the port connecting to Switch C
■ Switch B: the port connecting to Switch C
■ Switch C: the port connecting to Switch D
In this configuration, Switch C blocks the port connecting to Switch D as soon as it receives a
better (superior) BPDU. The port is put in a special STP state (root-inconsistent) that is effec-
tively the same as the Listening state. No traffic passes through the port in this state. As soon
as Device D stops sending superior BPDUs, the port is unblocked again and goes, via STP,
into the Listening and Learning states, and eventually transitions to the Forwarding state.
Recovery is automatic—no human intervention is required.
1439_CCNP_3.book Page 207 Wednesday, October 27, 2004 9:54 AM

STP Configuration 207

The following message appears when root guard blocks a port:


%SPANTREE-2-ROOTGUARDBLOCK: Port 1/1 tried to become non-designated in VLAN 77.
Moved to root-inconsistent state

STP Configuration
Configuring PVST+ on Catalyst switches involves configuring the Root Switches for each
VLAN and optionally configuring load sharing via Port Cost and Port Priority. The default
STP timers can be tuned in specialized situations.

Default STP Configuration


Table 3-7 shows the default STP (PVST/PVST+) configuration settings.

Table 3-7 The Default PVST+ Settings Include the Bridge Priority, Port Priority, and
Port Cost

Feature Default Setting

enable state Enabled on VLAN 1. Up to 64 spanning-tree


instances can be enabled.

switch priority 32768

spanning-tree port priority 128


(Can be configured on a per-interface
basis and used on interfaces configured
as Layer 2 access ports)

spanning-tree port cost 1000 Mbps: 4


(Can be configured on a per-interface 100 Mbps: 19
basis and used on interfaces configured 10 Mbps: 100
as Layer 2 access ports)

spanning-tree vlan port priority 128


(Can be configured on a per-VLAN
basis and used on interfaces configured
as Layer 2 trunk ports)

spanning-tree vlan port cost 1000 Mbps: 4


(Can be configured on a per-VLAN 100 Mbps: 19
basis and used on interfaces configured 10 Mbps: 100
as Layer 2 trunk ports)
continues
1439_CCNP_3.book Page 208 Wednesday, October 27, 2004 9:54 AM

208 Chapter 3: Spanning Tree Protocol (STP)

Table 3-7 The Default PVST+ Settings Include the Bridge Priority, Port Priority, and
Port Cost (Continued)

Feature Default Setting

Hello Time 2 seconds

Forward Delay Time 15 seconds

Max Age Time 20 seconds

Lab 3.10.1 STP Default Behavior


In this lab exercise, you observe STP’s default behavior.

Lab 3.10.2 Use Network Inspector to Observe STP Behavior


In this lab exercise, you observe STP behavior with the Network Inspector switch
trace feature.

NOTE Enabling and Disabling STP


In Cisco IOS Release STP is enabled by default on VLAN 1 and on all newly created VLANs up to the spanning-
12.1(9)EA1 and later, tree limit as specified. Disable STP only if the network topology has no loops. When STP is
Catalyst 2950 switches
support the IEEE 802.1t disabled and loops are present in the topology, excessive traffic and indefinite packet duplica-
STP extensions. Some tion can drastically reduce network performance.
of the bits previously
used for the switch pri- To re-enable STP, use the spanning-tree vlan vlan-id global configuration command.
ority are now used as
the VLAN identifier.
The result is that fewer Modifying the Root Switch
MAC addresses are
By default, switches with Cisco PVST and PVST+ maintain a separate spanning-tree
reserved for the switch,
and a larger range of instance for each active VLAN configured on them. A BID consisting of the switch priority
VLAN IDs can be sup- and the switch MAC address is associated with each instance. For each VLAN, the switch
ported, all while main-
taining the uniqueness with the lowest BID becomes the Root Bridge for that VLAN.
of the BID. The 2 bytes
previously used for To configure a switch to become the root for the specified VLAN, use the spanning-tree vlan
the switch priority are vlan-id root primary global configuration command to change the switch priority from the
reallocated into a
default value (32768) to a significantly lower value. When this command is entered, the switch
4-bit priority value and
a 12-bit extended sys- checks the switch priority of the Root Switches for each VLAN. Because of the extended sys-
tem ID value equal to tem ID support, the switch sets its own priority for the specified VLAN to 24576 if this value
the VLAN ID.
will cause this switch to become the root for the specified VLAN.
1439_CCNP_3.book Page 209 Wednesday, October 27, 2004 9:54 AM

STP Configuration 209

If any Root Bridge for the specified VLAN has a switch priority lower than 24576, the switch
sets its own priority for the specified VLAN to 4096 less than the lowest switch priority. 4096
is the value of the least-significant bit of a 4-bit switch priority value.
Beginning in privileged EXEC mode, follow the steps listed in Table 3-8 to configure a NOTE
switch to become the root for the specified VLAN. The spanning-tree
vlan vlan-id root
primary global config-
Table 3-8 A Single Command Is Used to Configure a Switch to Be the Root of the Spanning Tree
uration command fails
for a Particular VLAN
if the value necessary to
be the Root Switch is
Step Command Description less than 1.
1 configure terminal Enters global configuration mode.

2 spanning-tree vlan vlan-id root Configures a switch to become the root of


primary [diameter net-diameter the specified VLAN.
[hello-time seconds]] For vlan-id, the range is 1 to 4094 when the
Enhanced Image is installed and 1 to 1005
when the Standard Image is installed. Do not
enter leading 0s.
(Optional) For diameter net-diameter,
specify the maximum number of switches
between any two end stations. The range is
2 to 7.
(Optional) For hello-time seconds, specify
the interval in seconds between the genera-
tion of configuration messages by the Root
Bridge. The range is 1 to 10 seconds; the
default is 2 seconds.

3 end Returns to privileged EXEC mode.


4 show spanning-tree detail Verifies the entries.

Before Cisco IOS Release 12.1(9)EA1, entering the spanning-tree vlan vlan-id root primary
global configuration command on a Catalyst 2950 switch (no extended system ID) caused it
to set its own switch priority for the specified VLAN to 8192 if this value caused this switch
to become the root for the specified VLAN.
If any Root Switch for the specified VLAN has a switch priority lower than 8192, the
switch sets its own priority for the specified VLAN to 1 less than the lowest switch priority.
1439_CCNP_3.book Page 210 Wednesday, October 27, 2004 9:54 AM

210 Chapter 3: Spanning Tree Protocol (STP)

The following examples show the effect of the spanning-tree vlan vlan-id root primary
command with and without the extended system ID support:
■ For Catalyst 2950 switches with the extended system ID (Release 12.1(9)EA1 and
later), if all network devices in VLAN 20 have the default priority of 32768, entering
the spanning-tree vlan 20 root primary command on the switch sets the switch
priority to 24576, which causes this switch to become the Root Switch for VLAN 20.
■ For Catalyst 2950 switches without the extended system ID (software earlier than
Release 12.1(9)EA1), if all network devices in VLAN 100 have the default priority of
32768, entering the spanning-tree vlan 100 root primary command on the switch sets
the switch priority for VLAN 100 to 8192, which causes this switch to become the Root
Switch for VLAN 100.
If the network consists of switches that both do and do not support the extended system ID, it
is unlikely that the switch with the extended system ID support will become the Root Switch.
The extended system ID increases the switch priority value every time the VLAN number is
greater than the priority of the connected switches running older software.
The Root Switch for each spanning-tree instance should be a backbone or distribution switch.
Do not configure an access switch as the spanning-tree primary root.
Use the diameter keyword to specify the Layer 2 network diameter (that is, the maximum
number of switch hops between any two end stations in the Layer 2 network). When the net-
work diameter is specified, the switch automatically sets an optimal hello time, forward-delay
time, and maximum-age time for a network of that diameter, which can significantly reduce
the convergence time. The hello-time keyword can be used to override the automatically
calculated hello time.
After configuring the switch as the Root Switch, the recommended practice is to avoid
manual configuration of the hello time, forward-delay time, and maximum-age time using
the spanning-tree vlan vlan-id hello-time, spanning-tree vlan vlan-id forward-time, and
spanning-tree vlan vlan-id max-age global configuration commands.
To return the switch to its default setting, use the no spanning-tree vlan vlan-id root global
configuration command.

Setting the Priority for Ports and VLANs


If a loop occurs, STP uses the Port Priority when selecting an interface to put into the Forward-
ing state. Assign higher-priority values (lower numerical values) to interfaces that the net-
work administrator prefers to have selected first and lower-priority values (higher numerical
values) to interfaces that the network administrator wants selected last. If all interfaces have
the same priority value, STP puts the interface with the lowest interface number in the For-
warding state and blocks the other interfaces.
1439_CCNP_3.book Page 211 Wednesday, October 27, 2004 9:54 AM

STP Configuration 211

Cisco IOS uses the Port Priority value when the interface is configured as an access port and
uses VLAN Port Priority values when the interface is configured as a trunk port.
Beginning in privileged EXEC mode, follow the steps listed in Table 3-9 to configure an
interface’s Port Priority.

Table 3-9 Port Priority Can Be Configured on Interfaces to Influence the Spanning-Tree Topology

Step Command Description

1 configure terminal Enters global configuration mode.

2 interface interface-id Enters interface configuration mode and


specifies an interface to configure.
Valid interfaces include physical interfaces
and port-channel logical interfaces (port-
channel port-channel-number).

3 spanning-tree vlan port-priority Configures the Port Priority for an interface


priority that is an access port.
For priority, the range is 0 to 255; the
default is 128. The lower the number, the
higher the priority.

4 spanning-tree vlan vlan-id port- Configures the VLAN Port Priority for an
priority priority interface that is a trunk port.
For vlan-id, the range is 1 to 4094 when the
Enhanced Image is installed and 1 to 1005
when the Standard Image is installed. Do
not enter leading 0s.
For priority, the range is 0 to 255; the default
is 128. The lower the number, the higher
the priority.

5 end Returns to privileged EXEC mode.

6 show spanning-tree interface Verifies the entries.


interface-id
or
show spanning-tree vlan vlan-id

The show spanning-tree interface interface-id privileged EXEC command displays


information only if the port is in a link-up operative state. Otherwise, use the show running-
config interface privileged EXEC command to confirm the configuration.
1439_CCNP_3.book Page 212 Wednesday, October 27, 2004 9:54 AM

212 Chapter 3: Spanning Tree Protocol (STP)

To return the interface to its default setting, use the no spanning-tree [vlan vlan-id] port-
priority interface configuration command.

Lab 3.10.3 Advanced PVST+ Configuration


In this lab exercise, you modify the default PVST+ configuration to control the
spanning-tree behavior.

Setting the Port Cost


The spanning-tree Path Cost default value is derived from an interface’s media speed. If a
loop occurs, STP uses cost when selecting an interface to put in the Forwarding state. Assign
lower-cost values to interfaces that the network administrator prefers to have selected first
and higher-cost values to interfaces that the network administrator wants selected last. If all
interfaces have the same cost value, STP puts the interface with the lowest interface number
in the Forwarding state and blocks the other interfaces.
STP uses the cost value when the interface is configured as an access port and uses VLAN
port cost values when the interface is configured as a trunk port.
Beginning in privileged EXEC mode, follow the steps listed in Table 3-10 to configure an
interface’s cost.

Table 3-10 Port Cost Can Be Configured on Interfaces to Influence the Spanning-Tree
Topology

Step Command Description

1 configure terminal Enters global configuration mode.

2 interface interface-id Enters interface configuration mode and


specifies an interface to configure.
Valid interfaces include physical interfaces
and port-channel logical interfaces (port-
channel port-channel-number).

3 spanning-tree cost cost Configures the cost of an interface that is an


access port.
If a loop occurs, STP uses the Path Cost
when selecting an interface to place in the
Forwarding state. A lower Path Cost repre-
sents higher-speed transmission.
For cost, the range is 1 to 200000000; the
default value is derived from the interface’s
media speed.
1439_CCNP_3.book Page 213 Wednesday, October 27, 2004 9:54 AM

STP Configuration 213

Table 3-10 Port Cost Can Be Configured on Interfaces to Influence the Spanning-Tree
Topology (Continued)

Step Command Description

4 spanning-tree vlan vlan-id cost Configures the VLAN cost for an interface
cost that is a trunk port.
If a loop occurs, STP uses the Path Cost
when selecting an interface to place in the
Forwarding state. A lower Path Cost repre-
sents higher-speed transmission.
For vlan-id, the range is 1 to 4094 when the
Enhanced Image is installed and 1 to 1005
when the Standard Image is installed. Do
not enter leading 0s.
For cost, the range is 1 to 200000000; the
default value is derived from the interface’s
media speed.

5 end Returns to privileged EXEC mode.

6 show spanning-tree interface Verifies the entries.


interface-id
or
show spanning-tree vlan vlan-id

The show spanning-tree interface interface-id privileged EXEC command displays infor-
mation only for ports that are in a link-up operative state. Otherwise, use the show running-
config privileged EXEC command to confirm the configuration.
To return the interface to its default setting, use the no spanning-tree [vlan vlan-id] cost
interface configuration command.

Configuring Switch Priority of a VLAN


You can configure the switch priority to make it more likely that the switch will be chosen as
the Root Switch. For most situations, the recommended practice is to use the spanning-tree
vlan vlan-id root primary and spanning-tree vlan vlan-id root secondary global configura-
tion commands to modify the switch priority.
1439_CCNP_3.book Page 214 Wednesday, October 27, 2004 9:54 AM

214 Chapter 3: Spanning Tree Protocol (STP)

However, beginning in privileged EXEC mode, you can follow the steps outlined in Table 3-11
to configure a VLAN’s switch priority.

Table 3-11 Bridge Priority Can Be Configured to Influence the Spanning-Tree Topology

Step Command Description

1 configure terminal Enters global configuration mode.

2 spanning-tree vlan vlan-id Configures a VLAN’s switch priority.


port-priority priority For vlan-id, the range is 1 to 4094 when the
Enhanced Image is installed and 1 to 1005
when the Standard Image is installed. Do
not enter leading 0s.
For priority, the range is 0 to 61440 in
increments of 4096; the default is 32768.
The lower the number, the more likely the
switch will be chosen as the Root Switch.
Valid priority values are 4096, 8192, 12288,
16384, 20480, 24576, 28672, 32768,
36864, 40960, 45056, 49152, 53248,
57344, and 61440. All other values are
rejected.

3 end Returns to privileged EXEC mode.

4 show spanning-tree vlan vlan-id Verifies the entries.

To return the switch to its default setting, use the no spanning-tree vlan vlan-id priority
global configuration command.

Modifying Default Timers


IEEE 802.1D STP parameters can be individually configured in specialized situations. These
parameters include hello time, forward delay, and VLAN maximum aging time.

Hello Time
Changing the hello time configures the interval period of configuration messages generated
by the Root Switch. For most situations, it is recommended that you use the spanning-tree
vlan vlan-id root primary and spanning-tree vlan vlan-id root secondary global configuration
commands to modify the hello time.
1439_CCNP_3.book Page 215 Wednesday, October 27, 2004 9:54 AM

STP Configuration 215

However, beginning in privileged EXEC mode, you can follow the steps outlined in Table 3-12
to configure the hello time for a VLAN.

Table 3-12 The Default STP Hello Time Is 2 Seconds

Step Command Description

1 configure terminal Enters global configuration mode.

2 spanning-tree vlan vlan-id Configures a VLAN’s hello time. The hello


hello-time seconds time is the interval between the generation
of configuration messages by the Root
Switch. These messages mean that the
switch is alive.
For vlan-id, the range is 1 to 4094 when the
Enhanced Image is installed and 1 to 1005
when the Standard Image is installed. Do
not enter leading 0s.
For seconds, the range is 1 to 10; the default
is 2.

3 end Returns to privileged EXEC mode.

4 show spanning-tree vlan vlan-id Verifies the entries.

To return the switch to its default setting, use the no spanning-tree vlan vlan-id hello-time
global configuration command.

Forward Delay
Use the global configuration command spanning-tree vlan vlan-id forward-time seconds
command to configure the Forward Delay for a VLAN.
The forwarding time determines how long each of the Listening and Learning states last
before the interface begins forwarding. The range is 4 to 30 seconds.
To return the switch to its default setting, use the no spanning-tree vlan vlan-id forward-time
global configuration command.

VLAN Maximum Aging Time


Use the global configuration command spanning-tree vlan vlan-id max-age seconds com-
mand to configure the Max Age for a VLAN.
1439_CCNP_3.book Page 216 Wednesday, October 27, 2004 9:54 AM

216 Chapter 3: Spanning Tree Protocol (STP)

This command sets the interval between messages the spanning tree receives from the Root
Switch. If a switch does not receive a BPDU message from the Root Switch within this interval,
it recomputes the spanning-tree topology. The range is 6 to 40 seconds.
To return the switch to its default setting, use the no spanning-tree vlan vlan-id max-age
global configuration command.

Tuning, Verifying, and Troubleshooting STP


Cisco added several features to its PVST+ STP implementation. Configuring these options
can significantly enhance convergence time in switched networks. PortFast speeds up the
amount of time it takes an access port to transition to Forwarding state when a workstation or
router is attached. UplinkFast and BackboneFast speed up STP convergence when an uplink
trunk link or indirect trunk link fails, respectively. BPDU guard and root guard prevent rogue
devices or unintended devices from influencing spanning-tree behavior. This section also
explores spanning-tree load sharing.

Configuring PortFast
A port with the PortFast feature enabled is moved directly to the STP Forwarding state with-
out waiting for the standard forward-time delay.
Use PortFast only when connecting a single end station to an access or trunk port. Enabling
this feature on a port connected to a switch or hub could prevent STP from detecting and
disabling loops in the network, which could cause broadcast storms and address-learning
problems.
When the voice VLAN feature is enabled, the PortFast feature is automatically enabled.
When voice VLAN is disabled, the PortFast feature is not automatically disabled.
Enable PortFast if the switch is running PVST or Multiple Spanning Tree Protocol (MSTP).
Note that MSTP is available only if the EI is installed on the switch.
Beginning in privileged EXEC mode, follow the steps outlined in Table 3-13 to enable
PortFast.
Use the spanning-tree portfast global configuration command to globally enable the Port-
Fast feature on all nontrunking ports.
1439_CCNP_3.book Page 217 Wednesday, October 27, 2004 9:54 AM

Tuning, Verifying, and Troubleshooting STP 217

To disable the PortFast feature, use the no spanning-tree portfast interface configuration
command.

Table 3-13 PortFast Is Disabled by Default and Can Be Configured Per Interface

Step Command Description

1 configure terminal Enters global configuration mode.

2 spanning-tree portfast [trunk] Enables PortFast on an access port con-


nected to a single workstation or server. By
specifying the trunk keyword, you can
enable PortFast on a trunk port.

3 end Returns to privileged EXEC mode.

4 show spanning-tree interface Verifies the entries.


interface-id portfast

Configuring UplinkFast
UplinkFast RSTP incorporates an automatically enabled feature similar to the Cisco Uplink-
Fast proprietary STP extension. The 802.1w topology change mechanism clears the appropri-
ate entries in the CAM tables of the upstream bridges, removing the need for UplinkFast’s
dummy multicast generation process.
UplinkFast cannot be enabled on VLANs that have been configured for switch priority. To
enable UplinkFast on a VLAN with switch priority configured, first restore the switch priority
on the VLAN to the default value by using the no spanning-tree vlan vlan-id priority global
configuration command.
When UplinkFast is enabled, it affects all VLANs on the switch. UplinkFast cannot be con-
figured on an individual VLAN.
The UplinkFast feature is supported only when the switch is running PVST. Beginning in
privileged EXEC mode, follow the steps outlined in Table 3-14 to enable UplinkFast.
1439_CCNP_3.book Page 218 Wednesday, October 27, 2004 9:54 AM

218 Chapter 3: Spanning Tree Protocol (STP)

Table 3-14 UplinkFast Can Be Configured Only for All VLANs on a Switch; It Cannot Be Configured
on a Per-VLAN Basis

Step Command Description

1 configure terminal Enters global configuration mode.

2 spanning-tree uplinkfast Enables UplinkFast.


[max-update-rate pkts-per-second] (Optional) For pkts-per-second, the range is
0 to 65535 packets per second; the default
is 150.
If you set the rate to 0, station-learning
frames are not generated, and the spanning-
tree topology converges more slowly after a
loss of connectivity.

3 end Returns to privileged EXEC mode.

4 show spanning-tree summary Verifies the entries.

When UplinkFast is enabled, the switch priority of all VLANs is set to 49152. If the Path
Cost is changed to a value less than 3000 and then UplinkFast is enabled, or if UplinkFast
is already enabled, the Path Cost of all interfaces and VLAN trunks is increased by 3000. (If
the Path Cost is changed to 3000 or greater, the Path Cost is not altered.) The changes to the
switch priority and the Path Cost reduce the chance that the switch will become the Root
Switch.
When UplinkFast is disabled, the switch priorities of all VLANs and Path Costs of all inter-
faces are set to default values unless the defaults have been modified.
To return the update packet rate to the default setting, use the no spanning-tree uplinkfast
max-update-rate global configuration command. To disable UplinkFast, use the no
spanning-tree uplinkfast command.

Configuring BackboneFast
Accepting inferior BPDUs is what makes up the core of the BackboneFast engine. The IEEE
802.1w committee decided to incorporate a similar mechanism into RSTP. When a bridge
receives an inferior BPDU from its Designated or Root Switch, the bridge immediately
accepts this BPDU and replaces the one previously stored.
BackboneFast can be enabled to detect indirect link failures and to start the spanning-tree
reconfiguration sooner. You must enable BackboneFast on all switches in the network for it to
1439_CCNP_3.book Page 219 Wednesday, October 27, 2004 9:54 AM

Tuning, Verifying, and Troubleshooting STP 219

work properly. BackboneFast is not supported on Token Ring VLANs; however, Backbone-
Fast is supported for use with third-party switches.
The BackboneFast feature is supported only when the switch is running PVST. Beginning in
privileged EXEC mode, follow the steps outlined in Table 3-15 to enable BackboneFast.

Table 3-15 BackboneFast Must Be Configured on All Switches in the Network

Step Command Description

1 configure terminal Enters global configuration mode.

2 spanning-tree backbonefast Enables BackboneFast.

3 end Returns to privileged EXEC mode.

4 show spanning-tree summary Verifies the entries.

To disable the BackboneFast feature, use the no spanning-tree backbonefast global config-
uration command.

Configuring BPDU Guard


When BPDU guard is enabled globally on ports that are PortFast-enabled (the ports are in a
PortFast-operational state), STP shuts down PortFast-enabled ports that receive BPDUs.
In a valid configuration, PortFast-enabled ports do not receive BPDUs. Receiving a BPDU on
a PortFast-enabled port signals an invalid configuration, such as the connection of an unau-
thorized device, and the BPDU guard feature puts the port in the error-disabled state. The
BPDU guard feature provides a secure response to invalid configurations because the port
must be manually put back into service. Use the BPDU guard feature in a service provider
network to prevent an access port from participating in the spanning tree.
Configure PortFast only on ports that connect to end stations; otherwise, an accidental topol-
ogy loop could cause a data packet loop and disrupt switch and network operation.
Use the spanning-tree bpduguard enable interface configuration command to enable
BPDU guard on any port without also enabling the PortFast feature. When the port receives
a BPDU, it is put in the error-disabled state.
The BPDU guard feature can be enabled if the switch is running PVST or MSTP. MSTP is
available only if the Enhanced Image is installed on the switch.
1439_CCNP_3.book Page 220 Wednesday, October 27, 2004 9:54 AM

220 Chapter 3: Spanning Tree Protocol (STP)

Beginning in privileged EXEC mode, follow the steps outlined in Table 3-16 to globally enable
the BPDU guard feature on all access ports and to enable PortFast on all access ports.

Table 3-16 BPDU Guard Can Be Globally Configured, But PortFast Must Also Be Configured on the
Interfaces Connected to End Stations

Step Command Description

1 configure terminal Enters global configuration mode.

2 spanning-tree portfast Globally enables BPDU guard. By default,


bpduguard default BPDU guard is disabled.

3 interface interface-id Enters interface configuration mode and


specifies the interface connected to an end
station.

4 spanning-tree portfast Enables the PortFast feature.

5 end Returns to privileged EXEC mode.

6 show running-config Verifies the entries.

To disable BPDU guard on all access ports, use the no spanning-tree portfast bpduguard
default global configuration command. You can override this command on a particular inter-
face by using the spanning-tree bpduguard enable interface configuration command.

Lab 3.10.7 Port-Level Tuning to Control STP Behavior


In this lab exercise, you use PortFast, UplinkFast, BPDU guard, root guard, and
UDLD to control STP behavior on a port.

Configuring Root Guard


Root guard enabled on an interface applies to all the VLANs to which the interface belongs.
Do not enable the root guard on interfaces to be used by the UplinkFast feature. With Uplink-
Fast, the backup interfaces (in the blocked state) replace the Root Port in case of a failure.
However, if root guard is also enabled, all the backup interfaces used by the UplinkFast fea-
ture are placed in the root-inconsistent state (blocked) and are prevented from reaching the
Forwarding state. Root guard and loop guard cannot both be enabled at the same time.
Loop guard can be used to prevent alternate or Root Ports from becoming Designated Ports
because of a failure that leads to a unidirectional link. This feature is most effective when it is
1439_CCNP_3.book Page 221 Wednesday, October 27, 2004 9:54 AM

Tuning, Verifying, and Troubleshooting STP 221

configured on the entire switched network. Loop guard operates only on ports that the span-
ning tree considers point-to-point.
Root guard can be enabled if the switch is running PVST or MSTP. Recall that the MSTP fea-
ture is available only if the Enhanced Image is installed on the switch.
Beginning in privileged EXEC mode, follow the steps listed in Table 3-17 to enable root
guard on an interface.

Table 3-17 Root Guard Is Configured on Interfaces to Prevent Inadvertent Root Switch Election

Step Command Description

1 configure terminal Enters global configuration mode.

2 interface interface-id Enters interface configuration mode and


specifies the interface to configure.
3 spanning-tree guard root Enables root guard on the interface. By
default, root guard is disabled on all
interfaces.

4 end Returns to privileged EXEC mode.

5 show running-config Verifies the entries.

To disable root guard, use the no spanning-tree guard interface configuration command.

Configuring Load Sharing


Load sharing divides the bandwidth supplied by parallel trunks connecting switches. To avoid
loops, STP normally blocks all but one parallel link between switches. Using load sharing,
divide the traffic between the links according to which VLAN the traffic belongs to.
Configure load sharing on trunk ports by using STP port priorities or STP Path Costs. For
load sharing using STP port priorities, both load-sharing links must be connected to the same
switch. For load sharing using STP Path Costs, each load-sharing link can be connected to the
same switch or to two different switches.

Load Sharing Using STP Port Priorities


When two ports on the same switch form a loop, the STP Port Priority setting determines
which port is enabled and which port is in a Blocking state. The priorities on a parallel trunk
port can be set so that the port carries all the traffic for a given VLAN. The trunk port with
the higher priority (lower Port Priority values) for a VLAN forwards traffic for that VLAN.
1439_CCNP_3.book Page 222 Wednesday, October 27, 2004 9:54 AM

222 Chapter 3: Spanning Tree Protocol (STP)

The trunk port with the lower priority (higher Port Priority values) for the same VLAN
remains in a Blocking state for that VLAN. One trunk port sends or receives all traffic for the
VLAN.
Figure 3-47 shows two Gigabit Ethernet trunks connecting supported switches. In this example,
the switches are configured as follows:
■ VLANs 8 to 10 are assigned a Port Priority of 10 on Trunk 1.
■ VLANs 3 to 6 retain the default Port Priority of 128 on Trunk 1.
■ VLANs 3 to 6 are assigned a Port Priority of 10 on Trunk 2.
■ VLANs 8 to 10 retain the default Port Priority of 128 on Trunk 2.

Figure 3-47 Port Priority Can Be Configured to Enable STP Load Sharing

Switch 1

Trunk 1 Trunk 2
VLANs 8 to 10 (Priority 10) VLANs 3 to 6 (Priority 10)
VLANs 3 to 6 (Priority 128) VLANs 8 to 10 (Priority 128)

Switch 2

In this way, Trunk 1 carries traffic for VLANs 8 to 10, and Trunk 2 carries traffic for VLANs
3 to 6. If the active trunk fails, the trunk with the lower priority takes over and carries the traf-
fic for all the VLANs. No duplication of traffic occurs over any trunk port.
Beginning in privileged EXEC mode, follow the steps shown in Table 3-18 to configure the
network shown in Figure 3-47.

Table 3-18 Port Priority Can Be Configured on Interfaces to Affect STP Load Sharing

Step Command Description

1 interface gigabitethernet0/1 Enters interface configuration mode


and defines the interface to set the STP
Port Priority.

2 spanning-tree vlan 8 port-priority 10 Assigns a Port Priority of 10 for


VLAN 8.

3 spanning-tree vlan 9 port-priority 10 Assigns a Port Priority of 10 for


VLAN 9.
1439_CCNP_3.book Page 223 Wednesday, October 27, 2004 9:54 AM

Tuning, Verifying, and Troubleshooting STP 223

Table 3-18 Port Priority Can Be Configured on Interfaces to Affect STP Load Sharing (Continued)

Step Command Description

4 spanning-tree vlan 10 port-priority 10 Assigns a Port Priority of 10 for


VLAN 10.

5 exit Returns to global configuration mode.

6 interface gigabitethernet0/2 Enters interface configuration mode


and defines the interface to set the
STP Port Priority.

7 spanning-tree vlan 3 port-priority 10 Assigns a Port Priority of 10 for


VLAN 3.

8 spanning-tree vlan 4 port-priority 10 Assigns a Port Priority of 10 for


VLAN 4.

9 spanning-tree vlan 5 port-priority 10 Assigns a Port Priority of 10 for


VLAN 5.

10 spanning-tree vlan 6 port-priority 10 Assigns a Port Priority of 10 for


VLAN 6.

11 end Returns to privileged EXEC mode.

Load Sharing Using STP Path Cost


Parallel trunks can be configured to share VLAN traffic by setting different Path Costs on a
trunk and associating the Path Costs with different sets of VLANs. The VLANs keep the traffic
separate. Because no loops exist, STP does not disable the ports, and redundancy is main-
tained in the event of a lost link.
In Figure 3-48, trunk ports 1 and 2 are 100BASE-T ports. The Path Costs for the VLANs are
assigned as follows:
■ VLANs 2 to 4 are assigned a Path Cost of 30 on Trunk Port 1.
■ VLANs 8 to 10 retain the default 100BASE-T Path Cost of 19 on Trunk Port 1.
■ VLANs 8 to 10 are assigned a Path Cost of 30 on Trunk Port 2.
■ VLANs 2 to 4 retain the default 100BASE-T Path Cost of 19 on Trunk Port 2.
1439_CCNP_3.book Page 224 Wednesday, October 27, 2004 9:54 AM

224 Chapter 3: Spanning Tree Protocol (STP)

Figure 3-48 Port Cost Can Be Configured to Enable STP Load Sharing

Switch 1

Trunk Port 1 Trunk Port 2


VLANs 2 to 4 (Path Cost 30) VLANs 8 to 10 (Path Cost 30)
VLANs 8 to 10 (Path Cost 19) VLANs 2 to 4 (Path Cost 19)

Switch 2

Beginning in privileged EXEC mode, follow the steps outlined in Table 3-19 to configure the
network shown in Figure 3-48.

Table 3-19 Port Cost Can Be Configured on Interfaces to Affect STP Load Sharing

Step Command Description

1 configure terminal Enters global configuration mode on


Switch 1.

2 interface fastethernet 0/1 Enters interface configuration mode and


defines Fast Ethernet port 0/1 as the inter-
face to be configured as a trunk.
3 switchport trunk encapsulation Configures the trunk encapsulation.
dot1q

4 switchport mode trunk Configures the port as a trunk port.

5 exit Returns to global configuration mode.

6 Repeat Steps 2 to 4 on Switch 1 interface


Fast Ethernet 0/2.
7 end Returns to privileged EXEC mode.

8 show running-config Verifies your entries. In the display, make


sure that interfaces Fast Ethernet 0/1 and
Fast Ethernet 0/2 are configured as trunk
ports.

9 show vlan When the trunk links come up, Switch 1


receives the VLAN Trunking Protocol
(VTP) information from the other switches.
Verify that Switch 1 has learned the VLAN
configuration.
1439_CCNP_3.book Page 225 Wednesday, October 27, 2004 9:54 AM

Tuning, Verifying, and Troubleshooting STP 225

Table 3-19 Port Cost Can Be Configured on Interfaces to Affect STP Load Sharing (Continued)

Step Command Description

10 configure terminal Enters global configuration mode.

11 interface fastethernet 0/1 Enters interface configuration mode and


defines Fast Ethernet port 0/1 as the inter-
face to set the STP cost.

12 spanning-tree vlan 2 cost 30 Sets the spanning-tree Path Cost to 30 for


VLAN 2.

13 spanning-tree vlan 3 cost 30 Sets the spanning-tree Path Cost to 30 for


VLAN 3.

14 spanning-tree vlan 4 cost 30 Sets the spanning-tree Path Cost to 30 for


VLAN 4.

15 end Returns to global configuration mode.

16 Repeat Steps 9 to 11 on the Switch 1 inter-


face Fast Ethernet 0/2 and set the spanning-
tree Path Cost to 30 for VLANs 8, 9, and 10.

Lab 3.10.6 Per-VLAN Spanning-Tree Load Sharing


In this lab exercise, you modify spanning tree’s default behavior for VLAN load
sharing using Cisco IOS commands.

Verifying STP, RSTP, and MSTP Configuration


Table 3-20 lists and describes the privileged EXEC commands for displaying spanning-tree
status.

Table 3-20 show Commands for Verifying Spanning-Tree Configuration

Command Description

show spanning-tree Displays spanning-tree information on active interfaces only.


active

show spanning-tree Displays a detailed summary of interface information.


detail
continues
1439_CCNP_3.book Page 226 Wednesday, October 27, 2004 9:54 AM

226 Chapter 3: Spanning Tree Protocol (STP)

Table 3-20 show Commands for Verifying Spanning-Tree Configuration (Continued)

Command Description

show spanning-tree Displays spanning-tree information for the specified interface.


interface interface-id

show spanning-tree mst Displays MST information for the specified interface.
interface interface-id

NOTE show spanning-tree Displays a summary of port states or displays the total lines of
summary [totals] the STP state section.
Within each MST
region, the MSTP
maintains multiple
spanning-tree instances. For information about other keywords for the show spanning-tree privileged EXEC command,
Instance 0 is a special
instance for a region, refer to the command reference for the particular Cisco IOS release.
known as the internal
spanning tree (IST). All
other MST instances
are numbered from 1 to RSTP and MSTP Configuration
15. The IST is the only
spanning-tree instance
RSTP and MSTP can be used in place of the default PVST+ to improve Layer 2 convergence
that sends and receives in the network and to improve Catalyst switch CPU and memory utilization. Configuring
BPDUs. MST involves defining instances and assigning Layer 2 properties to each instance. Here you
A common and internal
learn how to enable RSTP, how to enable MST, and how to configure the MST Root Switch,
spanning tree (CIST) is a
collection of the inter- MST Bridge Priority, MST Path Cost, MST Port Priority, MSTP timers, and maximum hop
nal spanning trees in count.
each MST region and
the common spanning
tree (CST) that inter-
connects the MST
Default RSTP and MSTP Configuration
regions and single span- The switch uses the default settings of PVST/PVST+, as shown in Table 3-21. By default,
ning trees. RSTP/MST are not enabled.
The spanning tree
computed in a region
Table 3-21 The Default Settings for RSTP/MST Are Exactly the Same as Those for PVST+ Because
appears as a subtree in
RSTP/MST Is Disabled by Default
the CST that encom-
passes the entire
Feature Default Setting
switched domain. The
CIST is formed as a
Spanning-tree mode PVST (MSTP and RSTP are
result of the Spanning
Tree Algorithm run- disabled)
ning between switches
that support the 802.1w, switch priority 32768
802.1s, and 802.1D (Can be configured on a per-CIST interface basis)
protocols. The CIST
inside an MST region is spanning-tree port priority 128
the same as the CST
outside a region. (Can be configured on a per-CIST interface basis)
1439_CCNP_3.book Page 227 Wednesday, October 27, 2004 9:54 AM

RSTP and MSTP Configuration 227

Table 3-21 The Default Settings for RSTP/MST Are Exactly the Same as Those for PVST+ Because
RSTP/MST Is Disabled by Default (Continued)

Feature Default Setting

spanning-tree port cost 1000 Mbps: 4


(Can be configured on a per-CIST interface basis) 100 Mbps: 19
10 Mbps: 100

Hello Time 2 seconds

Forward Delay Time 15 seconds

Max Age Time 20 seconds

Maximum hop count 20 hops

RSTP and MSTP Configuration Guidelines


The configuration guidelines for RSTP and MSTP are as follows: TIP
Cisco.com includes an
■ Per-VLAN RSTP (PVRST) is not supported. When MST is enabled using the extensive set of techni-
spanning-tree mode mst global configuration command, RSTP is enabled. cal information describ-
ing RSTP and MSTP
■ PVST, PVST+, and MSTP are supported, but only one version can be active at any operation and configu-
time: all VLANs run PVST, or all VLANs run MSTP. ration, which you
can find at http://
■ VTP propagation of the MST configuration is not supported. Manually configure the www.cisco.com/
MST configuration (region name, revision number, and VLAN-to-instance mapping) univercd/cc/td/doc/
on each switch within the MST region by using the command-line interface (CLI) or product/lan/c3550/
12120ea2/3550scg/
through the SNMP support. swmstp.htm.
■ For load sharing across redundant paths in the network to work, all VLAN-to-instance
mapping assignments must match. Otherwise, all traffic flows on a single link.
■ All MST boundary ports must be forwarding for load sharing between a PVST+ and an
MST cloud. For this to happen, the IST master of the MST cloud should also be the
root of the CST. If the MST cloud consists of multiple MST regions, one of the MST
regions must contain the CST root, and all the other MST regions must have a better
path to the root contained with the MST cloud than a path through the PVST+ cloud. It
might be necessary to manually configure the switches in the clouds.
■ Partitioning the network into a large number of regions is not recommended. However,
if this situation is unavoidable, it is recommended that the switched LAN be partitioned
into smaller LANs interconnected by routers or non-Layer 2 devices.
1439_CCNP_3.book Page 228 Wednesday, October 27, 2004 9:54 AM

228 Chapter 3: Spanning Tree Protocol (STP)

Enabling RSTP and MSTP


For two or more switches to be in the same MST region, they must have the same VLAN-
to-instance mapping, the same configuration revision number, and the same name.
A region can have one member or multiple members with the same MST configuration. Each
member must be capable of processing RSTP BPDUs. There is no limit to the number of
MST regions in a network, and each region can support up to 16 spanning-tree instances. A
VLAN can be assigned to only one spanning-tree instance at a time.
Beginning in privileged EXEC mode, follow the steps outlined in Table 3-22 to specify the
MST region configuration and enable MSTP.

Table 3-22 Up to 16 Spanning-Tree Instances Can Be Configured with MST

Step Command Description

1 configure terminal Enters global configuration mode.


2 spanning-tree mst configuration Enters MST configuration mode.

3 instance instance-id vlan vlan-range Maps VLANs to an MST instance.


For instance-id, the range is 1 to 15.
For vlan vlan-range, the range is 1 to
4094.
When you map VLANs to an MST
instance, the mapping is incremental, and
the range of VLANs specified is added to
or removed from the existing ones.
To specify a range, use a hyphen. For
example, instance 1 vlan 1-63 maps
VLANs 1 through 63 to MST instance 1.
To specify a series, use a comma. For
example, instance 1 vlan 10, 20, 30 maps
VLANs 10, 20, and 30 to MST instance 1.

4 name name Specifies the configuration name. The


name string has a maximum length of
32 characters and is case-sensitive.

5 revision version Specifies the configuration revision num-


ber. The range is 0 to 65535.

6 show pending Verifies your configuration by displaying


the pending configuration.
1439_CCNP_3.book Page 229 Wednesday, October 27, 2004 9:54 AM

RSTP and MSTP Configuration 229

Table 3-22 Up to 16 Spanning-Tree Instances Can Be Configured with MST (Continued)

Step Command Description

7 exit Applies all changes and returns to global


configuration mode.

8 spanning-tree mode mst Enables MSTP. RSTP is also enabled.


Caution: Changing spanning-tree modes
can disrupt traffic because all spanning-
tree instances are stopped for the previous
mode and restarted in the new mode.

9 end Returns to privileged EXEC mode.

10 show running-config Verifies your entries.

To return to the default MST region configuration, use the no spanning-tree mst configuration
global configuration command. To return to the default VLAN-to-instance map, use the no
instance instance-id [vlan vlan-range] MST configuration command. To return to the default
name, use the no name MST configuration command. To return to the default revision number,
use the no revision MST configuration command.
To re-enable PVST, use the no spanning-tree mode or the spanning-tree mode pvst global
configuration command.
Example 3-1 demonstrates how to enter MST configuration mode, map VLANs 10 to 20 to
MST instance 1, name the region region1, set the configuration revision to 1, display the
pending configuration, apply the changes, and return to global configuration mode. MST
information is not propagated in VTP updates, so this configuration must be done on all the
appropriate switches.

Example 3-1 Mapping VLANs 10 to 20 to MST Instance 1

Switch(config)#spanning-tree mst configuration


Switch(config-mst)#instance 1 vlan 10-20
Switch(config-mst)#name region1
Switch(config-mst)#revision 1
Switch(config-mst)#show pending
Pending MST configuration
Name [region1]
Revision 1
continues
1439_CCNP_3.book Page 230 Wednesday, October 27, 2004 9:54 AM

230 Chapter 3: Spanning Tree Protocol (STP)

Example 3-1 Mapping VLANs 10 to 20 to MST Instance 1 (Continued)

Instance Vlans Mapped


-------- ------------------------
0 1-9, 21-4094
1 10-20
---------------------------------
Switch(config-mst)#exit
Switch(config)#

Configuring the MST Root Switch


The switch maintains a spanning-tree instance for the group of VLANs mapped to it. A BID,
consisting of the switch priority and the switch MAC address, is associated with each
instance. The switch with the lowest BID becomes the Root Switch for the group of VLANs.
To configure a switch to become the root, use the spanning-tree mst instance-id root global
configuration command to modify the switch priority from the default value (32768) to a
significantly lower value so that the switch becomes the Root Switch for the specified
spanning-tree instance. When this command is issued, the switch checks the switch priorities
of the Root Switches. Because of the extended system ID support, the switch sets its own pri-
ority for the specified instance to 24576 if this value will cause this switch to become the root
for the specified spanning-tree instance.
If any Root Switch for the specified instance has a switch priority lower than 24576, the
switch sets its own priority to 4096 less than the lowest switch priority. 4096 is the value of
the least-significant bit of a 4-bit switch priority value.
Catalyst 2950 switches running Cisco IOS software earlier than Release 12.1(9)EA1 do not
support the extended system ID. Catalyst 2950 switches running Cisco IOS software earlier
than Release 12.1(9)EA1 do not support the MSTP.
If the network consists of switches that both do and do not support the extended system ID, it
is unlikely that the switch with the extended system ID support will become the Root Switch.
The extended system ID increases the switch priority value every time the VLAN number is
greater than the priority of the connected switches running older software.
The Root Switch for each spanning-tree instance should be a backbone or distribution switch.
Do not configure an access switch as the spanning-tree primary root.
Use the diameter keyword, which is available only for MST instance 0, to specify the Layer 2
network diameter (that is, the maximum number of switch hops between any two end stations
in the Layer 2 network). When specifying the network diameter, the switch automatically sets
an optimal hello time, forward-delay time, and maximum-age time for a network of that
1439_CCNP_3.book Page 231 Wednesday, October 27, 2004 9:54 AM

RSTP and MSTP Configuration 231

diameter, which can significantly reduce the convergence time. Use the hello keyword to
override the automatically calculated hello time.
The recommended practice is that you avoid manually configuring the hello time, forward-
delay time, and maximum-age time. In other words, the recommended practice is to avoid
using the spanning-tree mst hello-time, spanning-tree mst forward-time, and spanning-tree
mst max-age global configuration commands after configuring the switch as the Root Switch.
Beginning in privileged EXEC mode, follow the steps outlined in Table 3-23 to configure a
switch as the Root Switch.

Table 3-23 Configuring the Root Switch with MST Is Done Per Instance Instead of Per VLAN

Step Command Description

1 configure terminal Enters global configuration mode.


2 spanning-tree mst instance-id root Configures a switch as the Root Switch.
primary [diameter net-diameter For instance-id, the range is 0 to 15.
[hello-time seconds]]
(Optional) For diameter net-diameter,
specify the maximum number of switches
between any two end stations. The range
is 2 to 7. This keyword is available only
for MST instance 0.
(Optional) For hello-time seconds, specify
the interval in seconds between the gener-
ation of configuration messages by the
Root Switch. The range is 1 to 10 seconds;
the default is 2 seconds.

3 end Returns to privileged EXEC mode.


4 show spanning-tree mst instance-id Verifies your entries.

To return the switch to its default setting, use the no spanning-tree mst instance-id root global
configuration command.

Lab 3.10.4 Implementing MST


In this lab exercise, you implement MST in a switched network.
1439_CCNP_3.book Page 232 Wednesday, October 27, 2004 9:54 AM

232 Chapter 3: Spanning Tree Protocol (STP)

Configuring MST Switch Priority


The switch priority can be configured to make it more likely that the switch will be chosen as
the Root Switch. Exercise care when using the spanning-tree mst instance-id priority global
configuration command. For most situations, it is recommended that you use the spanning-
tree mst instance-id root primary and spanning-tree mst instance-id root secondary global
configuration commands to modify the switch priority.
Beginning in privileged EXEC mode, follow the steps outlined in Table 3-24 to configure the
switch priority.

Table 3-24 MST Bridge Priority Can Also Be Used to Influence Root Bridge Election

Step Command Description

1 configure terminal Enters global configuration mode.

2 spanning-tree mst instance-id Configures the switch priority for an MST


priority priority instance.
For instance-id, the range is 0 to 15.
For priority, the range is 0 to 61440 in
increments of 4096; the default is 32768.
The lower the number, the more likely the
switch will be chosen as the Root Switch.
Valid priority values are 0, 4096, 8192,
12288, 16384, 20480, 24576, 28672,
32768, 36864, 40960, 45056, 49152,
53248, 57344, and 61440. All other values
are rejected.

3 end Returns to privileged EXEC mode.

4 show spanning-tree mst instance-id Verifies your entries.

To return the switch to its default setting, use the no spanning-tree mst instance-id priority
global configuration command.

Configuring MST Path Cost


The MST Path Cost default value is derived from an interface’s media speed. If a loop occurs,
the MSTP uses cost when selecting an interface to put in the Forwarding state. Assign lower-
cost values to interfaces that the network administrator wants selected first and higher-cost
values to interfaces that the administrator wants selected last. If all interfaces have the same
1439_CCNP_3.book Page 233 Wednesday, October 27, 2004 9:54 AM

RSTP and MSTP Configuration 233

cost value, the MSTP puts the interface with the lowest interface number in the Forwarding
state and blocks the other interfaces.
Beginning in privileged EXEC mode, follow the steps outlined in Table 3-25 to configure an
interface’s MSTP cost.

Table 3-25 MST Port Cost Can Be Configured to Alter the Default MST Topology

Step Command Description

1 configure terminal Enters global configuration mode.

2 interface interface-id Enters interface configuration mode and


specifies an interface to configure. Valid
interfaces include physical ports and port
channels. Valid port-channel numbers are
1 to 6.

3 spanning-tree mst instance-id cost Configures the cost of an MST instance.


cost If a loop occurs, MSTP uses the Path Cost
when selecting an interface to place in the
Forwarding state. A lower Path Cost repre-
sents higher-speed transmission.
For instance-id, the range is 0 to 15.
For cost, the range is 1 to 200000000; the
default is derived from the interface’s
media speed.

4 end Returns to privileged EXEC mode.

5 show spanning-tree mst interface Verifies your entries.


instance-id
or
show spanning-tree mst instance-id

The show spanning-tree mst interface interface-id privileged EXEC command displays
information only for ports that are in a link-up operative state. Otherwise, use the show run-
ning-config privileged EXEC command to confirm the configuration.
To return the interface to its default setting, use the no spanning-tree mst instance-id cost
interface configuration command.
1439_CCNP_3.book Page 234 Wednesday, October 27, 2004 9:54 AM

234 Chapter 3: Spanning Tree Protocol (STP)

Configuring MST Port Priority


If a loop occurs, MSTP uses the Port Priority when selecting an interface to put in the For-
warding state. Assign higher-priority values (lower numerical values) to interfaces that the
network administrator wants selected first and lower-priority values (higher numerical values)
to interfaces that the administrator wants selected last. If all interfaces have the same priority
value, the MSTP puts the interface with the lowest interface number in the Forwarding state
and blocks the other interfaces.
Beginning in privileged EXEC mode, follow the steps outlined in Table 3-26 to configure an
interface’s MSTP Port Priority.

Table 3-26 MST Port Priority Can Be Configured to Alter the Default MST Topology

Step Command Description

1 configure terminal Enters global configuration mode.


2 interface interface-id Enters interface configuration mode and
specifies an interface to configure. Valid
interfaces include physical ports and port
channels. Valid port-channel numbers are
1 to 6.

3 spanning-tree mst instance-id Configures the Port Priority for an MST


port-priority priority instance.
For instance-id, the range is 0 to 15.
For priority, the range is 0 to 255; the
default is 128. The lower the number, the
higher the priority.

4 end Returns to privileged EXEC mode.


5 show spanning-tree mst interface Verifies your entries.
instance-id
or
show spanning-tree mst instance-id

The show spanning-tree mst interface interface-id privileged EXEC command displays
information only if the port is in a link-up operative state. Use the show running-config
interface privileged EXEC command to confirm the configuration.
1439_CCNP_3.book Page 235 Wednesday, October 27, 2004 9:54 AM

RSTP and MSTP Configuration 235

To return the interface to its default setting, use the no spanning-tree mst instance-id port-
priority interface configuration command.

Configuring MSTP Timers


The MSTP Hello time, MSTP Forward Delay time, and MSTP Maximum Aging time can be
configured. This section explores the steps to configuring these timers.

MSTP Hello Time


You can change how often the Root Switch generates configuration messages by adjusting the
hello time. Exercise care when using this command. For most situations, the recommended
practice is to use the spanning-tree mst instance-id root primary and spanning-tree mst
instance-id root secondary global configuration commands to modify the hello time.
Beginning in privileged EXEC mode, follow the steps outlined in Table 3-27 to configure the
hello time for all MST instances.

Table 3-27 The MST Hello Time Can Be Configured to Alter the Default Value of 2 Seconds

Step Command Description

1 configure terminal Enters global configuration mode.

2 spanning-tree mst hello-time Configures the hello time for all MST
seconds instances. The hello time is the interval
between the generation of configuration
messages by the Root Switch. These mes-
sages mean that the switch is alive.
For seconds, the range is 1 to 10; the
default is 2.
3 end Returns to privileged EXEC mode.

4 show spanning-tree mst Verifies your entries.

To return the switch to its default setting, use the no spanning-tree mst hello-time global
configuration command.

MSTP Forward Delay Time


Beginning in privileged EXEC mode, follow the steps shown in Table 3-28 to configure the
forward delay time for all MST instances.
1439_CCNP_3.book Page 236 Wednesday, October 27, 2004 9:54 AM

236 Chapter 3: Spanning Tree Protocol (STP)

Table 3-28 The MST Forward Delay Can Be Configured to Alter the Default Value of 15 Seconds

Step Command Description

1 configure terminal Enters global configuration mode.

2 spanning-tree mst forward-time Configures the forward time for all MST
seconds instances. The forward time is the number
of seconds a port waits before changing
from its STP Learning and Listening states
to the Forwarding state.
For seconds, the range is 4 to 30; the
default is 15.

3 end Returns to privileged EXEC mode.


4 show spanning-tree mst Verifies your entries.

To return the switch to its default setting, use the no spanning-tree mst forward-time global
configuration command.

MSTP Maximum Aging Time


Beginning in privileged EXEC mode, follow the steps outlined in Table 3-29 to configure the
maximum aging time for all MST instances.

Table 3-29 The MST Max Age Can Be Configured to Alter the Default Value of 20 Seconds

Step Command Description

1 configure terminal Enters global configuration mode.


2 spanning-tree mst max-age Configures the maximum aging time for
seconds all MST instances. The maximum aging
time is the number of seconds a switch
waits without receiving spanning-tree con-
figuration messages before attempting a
reconfiguration.
For seconds, the range is 6 to 40; the
default is 20.

3 end Returns to privileged EXEC mode.

4 show spanning-tree mst Verifies your entries.


1439_CCNP_3.book Page 237 Wednesday, October 27, 2004 9:54 AM

EtherChannel 237

To return the switch to its default setting, use the no spanning-tree mst max-age global con-
figuration command.

Configuring Maximum Hop Count


Beginning in privileged EXEC mode, follow the steps outlined in Table 3-30 to configure the
maximum hop count for all MST instances.

Table 3-30 The MST Maximum Hop Count Can Be Configured to Alter the Default Value of 20 Hops

Step Command Description

1 configure terminal Enters global configuration mode.

2 spanning-tree mst max-hops Specifies the number of hops in a region


hop-count before the BPDU is discarded and the
information held for port is aged.
For hop-count, the range is 1 to 40; the
default is 20.

3 end Returns to privileged EXEC mode.

4 show spanning-tree mst Verifies your entries.

To return the switch to its default setting, use the no spanning-tree mst max-hops global
configuration command.

EtherChannel
EtherChannel is a Cisco-proprietary technology that, by aggregating links into a single logi-
cal link, provides incremental trunk speeds ranging from 10 Mbps to 160 Gbps (full duplex).
EtherChannel comes in four flavors:
■ Standard EtherChannel
■ Fast EtherChannel (FEC)
■ Gigabit EtherChannel (GEC)
■ 10-Gigabit EtherChannel
The term EtherChannel encompasses all these technologies. EtherChannel combines up to
eight standard Ethernet links (160 Mbps on a Catalyst 3000), up to eight Fast Ethernet links
(1.6 Gbps), up to eight Gigabit Ethernet links (16 Gbps), and up to eight 10 Gigabit Ethernet
links (160 Gbps).
1439_CCNP_3.book Page 238 Wednesday, October 27, 2004 9:54 AM

238 Chapter 3: Spanning Tree Protocol (STP)

EtherChannel Explained
EtherChannel provides fault-tolerant, high-speed links between switches, routers, and servers,
as shown in Figure 3-49. The term heard most often in the context of EtherChannel is “resil-
iency.” Cisco defines resiliency as “the ability to recover from any network failure or issue,
whether it is related to a disaster, link, hardware, design, or network service.” Recall STP and
how it handles link failures within a Layer 2 topology. With EtherChannel, resiliency refers to
EtherChannel’s ability to continue to operate when one of the links in a “bundle” goes down
as well as its ability to restore the full bundle should the downed link come back into service.
Chapter 2, “VLANs and VTP,” discussed trunking technologies. In particular, it looked at the
IEEE 802.1Q and ISL Ethernet trunking technologies. What might not have been made clear
at that time is that Ethernet trunks frequently go hand in hand with EtherChannel links. The
reason for this should be clear. Trunk links carry more traffic and require more bandwidth
than access links.

Figure 3-49 EtherChannel Enables Logical Links with Aggregate Bandwidth of Up to 160 Gbps

A 100/1000 Ethernet 1 B

100/1000 Ethernet 2
100/1000 Ethernet 3
100/1000 Ethernet 4
EtherChannel EtherChannel
100/1000 Ethernet 5
100/1000 Ethernet 6
100/1000 Ethernet 7
100/1000 Ethernet 8

EtherChannel bundles segments into groups of two to eight links. This lets links scale at rates
between 100 Mbps and a healthy fraction of 1 Tbps. T1 or 1.544 Mbps used to be the fastest
WAN link available. Now it is at least 16 Tbps for up to a 50-kilometer stretch with single-
mode fiber, using the Catalyst 6500 10GBASE-EX4 Metro 10 Gigabit Ethernet module.
EtherChannel operates as either an access link or trunk link. For example, EtherChannel can
1439_CCNP_3.book Page 239 Wednesday, October 27, 2004 9:54 AM

EtherChannel 239

be deployed between the wiring closet and the data center, as illustrated in Figure 3-50. In the
data center, EtherChannel links can be deployed between servers and the network backbone
to provide scalable incremental bandwidth.

Figure 3-50 EtherChannel Can Be Deployed Between the Wiring Closet and the Data Center

Data Center

400 Mbps 400 Mbps 400 Mbps

Wiring Closets

Some of the benefits of EtherChannel are as follows:


■ EtherChannel does not require any changes because it is transparent to networked
applications. For support of EtherChannel on enterprise-class servers and NICs, smart
software drivers can coordinate distribution of loads across multiple network interfaces.
■ When EtherChannel is used within the campus, switches and routers provide load dis-
tribution transparently across multiple links to network users. Unicast, multicast, and
broadcast traffic is distributed across the links in the channel.
■ EtherChannel provides automatic recovery for loss of a link by redistributing loads
across remaining links. If a link does fail, EtherChannel redirects traffic from the failed
link to the remaining links in less than a second. This convergence is transparent to the
end user. No host protocol timers expire, so no sessions are dropped.
Figure 3-51 shows a typical EtherChannel network configuration.
Now that you have a fair understanding of EtherChannel technology, you can investigate how
it works and how to configure it in a network. The following section explains how Ether-
Channel uses frame distribution.
1439_CCNP_3.book Page 240 Wednesday, October 27, 2004 9:54 AM

240 Chapter 3: Spanning Tree Protocol (STP)

Figure 3-51 All Catalyst Switches Support EtherChannel. Catalyst 6500 Switches Support
10 Gigabit EtherChannel (10 GEC). Catalyst 2950-T, Catalyst 3550, and Catalyst 4500
Switches Support Gigabit EtherChannel (GEC). Other Catalyst Switches Support Only
Fast EtherChannel (FEC) or EtherChannel.

Catalyst 8500,
6000, 5500, or
4000 Series
Switch

Gigabit EtherChannel

Catalyst 3550-12T
Switch

1000BASE-X 1000BASE-X

Catalyst 2950-T Catalyst 2950-T


Switch Switch

10/100 10/100
Switched Links Switched Links

Workstations Workstations

Frame Distribution
EtherChannel balances the traffic load across the links in a channel by applying an algorithm
to a portion of the binary pattern extracted from addresses in the Ethernet frame or encapsu-
lated data packets. The algorithm output is a numeric value that is then associated with one of
the links in the channel. On IOS-based switches, Catalyst 4000 series switches, and Catalyst
5000/5500 family switches, EtherChannel load distribution can be based on either source
MAC or destination MAC addresses. On the Catalyst 6000 family of switches, the load-
balancing policy (frame distribution) can be based on a MAC address, IP address, or Port
Number. With source MAC address forwarding, when packets are forwarded to an Ether-
Channel, they are distributed across the ports in the channel based on the incoming packet’s
source MAC address. Therefore, to provide load distribution, frames from different hosts use
different ports in the channel, but frames from the same host use the same port in the channel.
With destination MAC address forwarding, when frames are forwarded to an EtherChannel,
they are distributed across the ports in the channel based on the MAC address of the destina-
tion host in the incoming frame. Therefore, frames to the same destination are forwarded over
1439_CCNP_3.book Page 241 Wednesday, October 27, 2004 9:54 AM

EtherChannel 241

the same port, and frames to a different destination might be sent on a different port in the
channel.
The most recent EtherChannel frame distribution process is based on a Cisco-proprietary
hashing algorithm. Hash algorithms, such as Message Digest 5 (MD5), are normally used to
ensure that traffic arriving at the destination is identical to that generated at the source; how-
ever, the hash algorithm used with EtherChannel is designed to consistently and somewhat
randomly distribute Ethernet frames across member links in an EtherChannel. The algorithm
is deterministic, meaning that given the same addresses and session information, it always
hashes to the same port in the channel, preventing out-of-order frame delivery.
Although EtherChannel frame distribution based on a MAC address, IP address, or Layer 4
Port Number is possible, the configurable options allow for distribution based on source only
(MAC, IP, or port), destination only (MAC, IP, or port), or both source and destination (MAC,
IP, or port). The mode selected applies to all EtherChannels configured on the switch. Use
the option that provides the greatest variety in the configuration. For example, if the traffic
on a channel is going to a single MAC address only, using source addresses, IP addresses, or
Layer 4 Port Numbers as the basis for frame distribution might provide better frame distribu-
tion than selecting MAC addresses as the basis.
In Figure 3-52, an EtherChannel connects a Catalyst 2950 to a router. The switch is also
connected to four workstations. Because the router is referenced by the switch with a single
MAC address, source-based forwarding on the switch EtherChannel ensures that the switch
uses all available bandwidth to the router. The router is configured for destination-based for-
warding because the large number of workstations ensures that the traffic is evenly distributed
from the router EtherChannel.
Cisco 7000, 7200, 7500, 7600, and 8500 routers support Fast EtherChannels via logical port
channel interfaces binding Fast Ethernet interfaces. Cisco 7600 and 8500 routers also support
Gigabit EtherChannel.

EtherChannel Methods
EtherChannel uses two methods to negotiate bundles:
■ Port Aggregation Protocol (PAgP): Cisco-proprietary
■ Link Aggregation Control Protocol (LACP): IEEE 802.3ad
1439_CCNP_3.book Page 242 Wednesday, October 27, 2004 9:54 AM

242 Chapter 3: Spanning Tree Protocol (STP)

Figure 3-52 Source-Based Frame Distribution Is Used on the Switch, and Destination-Based Frame
Distribution Is Used on the Router

Catalyst 2950 switch


with source-based
forwarding enabled.

EtherChannel
Cisco router with
destination-based
forwarding enabled.

Port Aggregation Protocol (PAgP)


Port Aggregation Protocol (PAgP) is a Cisco-proprietary technology that facilitates the auto-
matic creation of EtherChannels by exchanging packets between Ethernet interfaces. By
using PAgP, the switch learns the identity of partners that can support PAgP and learns the
capabilities of each interface. It then dynamically groups similarly configured interfaces into
a single logical link (channel or aggregate port). These interfaces are grouped based on hard-
ware, administrative, and port parameter constraints. For example, PAgP groups the inter-
faces with the same speed, duplex mode, native VLAN, VLAN range, and trunking status and
type. After grouping the links into an EtherChannel, PAgP adds the group to the spanning tree
as a single switch port.
Table 3-31 lists and defines the various PAgP modes.

Table 3-31 PAgP Modes

Mode or Keyword Description

on The mode that forces the port to channel without PAgP. With the on
mode, a usable EtherChannel exists only when a port group in on
mode is connected to another port group in on mode.

off The mode that prevents the port from channeling.


1439_CCNP_3.book Page 243 Wednesday, October 27, 2004 9:54 AM

EtherChannel 243

Table 3-31 PAgP Modes (Continued)

Mode or Keyword Description

auto The mode that places a port in a passive negotiating state, in which
the port responds to PAgP packets it receives but does not initiate
PAgP packet negotiation. This is the default setting.

desirable The mode that places a port in an active negotiating state, in which
the port initiates negotiations with other ports by sending PAgP
packets.

silent The keyword that is used with auto or desirable mode when no traffic
is expected from the other device. This option prevents the link from
being reported to STP as down. This is the default, secondary PAgP
setting.

non-silent The keyword that is used with auto or desirable mode when traffic is
expected from the other device.

As described in Table 3-31, EtherChannel includes the four user-configurable modes of on,
off, auto, and desirable. Only auto and desirable are PAgP modes. The auto and desirable
modes can be modified with the silent and non-silent keywords. By default, ports are in auto-
silent mode. Both the auto and desirable modes allow ports to negotiate with connected ports
to determine if they can form an EtherChannel, based on criteria such as port speed, trunking
state, and VLAN numbers.
The on mode forces the port to channel without PAgP. With the on mode, a usable EtherChannel
exists only when a port group in on mode is connected to another port group in on mode. The
off mode prevents the port from channeling. The auto mode places a port in a passive negoti-
ating state, in which the port responds to PAgP packets it receives but does not initiate PAgP
packet negotiation. This is the default setting. The desirable mode places a port in an active
negotiating state, in which the port initiates negotiations with other ports by sending PAgP
packets.
Ports can form an EtherChannel when they are in different PAgP modes as long as the modes
are compatible. For example, a port in desirable mode can form an EtherChannel successfully
with another port that is in desirable or auto mode. A port in auto mode can form an EtherChannel
with another port in desirable mode. A port in auto mode cannot form an EtherChannel with
another port that is also in auto mode, because neither port initiates negotiation, as shown in
Table 3-32.
1439_CCNP_3.book Page 244 Wednesday, October 27, 2004 9:54 AM

244 Chapter 3: Spanning Tree Protocol (STP)

Table 3-32 Different Combinations of PAgP Modes on Either End of a Potential EtherChannel Might
or Might Not Result in a Valid EtherChannel Bundle

Valid EtherChannel Modes Invalid EtherChannel Modes

on-on off-any

auto-desirable auto-auto

desirable-desirable on-desirable

on-auto

On CatOS switches, configuring an EtherChannel automatically creates an administrative


group, designated by an integer between 1 and 1024, to which the EtherChannel belongs. If
preferred, specify the administrative group number. Forming a channel without specifying an
administrative group number creates a new automatically numbered administrative group. An
administrative group can contain a maximum of eight ports. In addition, on CatOS switches,
each EtherChannel is automatically assigned a unique EtherChannel ID.

Link Aggregation Control Protocol (LACP)


The open-standard equivalent to PAgP is Link Aggregation Control Protocol (LACP).
Defined in IEEE 802.3ad, LACP allows Cisco switches to manage Ethernet channels with
non-Cisco devices conforming to the 802.3ad specification. It is likely that LACP will
become the norm for Catalyst switches, just as Cisco migrated from ISL to IEEE 802.1Q.
(Cisco cannot always wait for the IEEE to complete its standards process before incorporat-
ing new features on its devices.) To have LACP handle channeling, use the active and passive
channel modes. To start automatic Ethernet channel configuration with LACP, configure at
least one end of the link to active mode to initiate channeling, because ports in passive mode
passively respond to initiation and never initiate the sending of LACP packets. Table 3-33
lists and defines the various LACP modes.

Table 3-33 LACP Modes

Mode Description

on Forces the port to channel without LACP. With the on mode, a


usable EtherChannel exists only when a port group in on mode
is connected to another port group in on mode.

off Prevents the port from channeling.


1439_CCNP_3.book Page 245 Wednesday, October 27, 2004 9:54 AM

EtherChannel 245

Table 3-33 LACP Modes (Continued)

Mode Description

passive Similar to the auto mode for PAgP, passive mode places a port
in a passive negotiating state, in which the port responds to
LACP packets it receives but does not initiate LACP packet
negotiation. Passive is the default mode.

active Similar to the desirable mode for PAgP, active mode places a
port in an active negotiating state, in which the port initiates
negotiation with other ports by sending LACP packets.

The on mode forces the port to channel without LACP. With the on mode, a usable EtherChannel
exists only when a port group in on mode is connected to another port group in on mode. The
off mode prevents the port from channeling. The passive mode is similar to the PAgP auto
mode, because it places the port in a passive negotiating state, in which the port responds to
LACP packets it receives but does not initiate LACP packet negotiation. Passive mode is the
default LACP mode.
When enabled, LACP always tries to configure the maximum number of compatible ports in
a channel, up to the maximum allowed by the hardware (eight ports for Catalyst switches). If
LACP cannot aggregate all the ports that are compatible (for example, if the remote system
has more restrictive hardware limitations), all the ports that cannot be actively included in the
channel are put in hot-standby state and are used only if one of the channeled ports fails.

Modifying Port Cost for EtherChannel Groups


If Port Cost is not specified, the STP Port Cost is updated based on the current Port Costs of
the channeling ports. However, if channel Port Cost is specified, the Port Costs of member
ports in the channel are modified to reflect the new cost. This enables load sharing of VLAN
traffic across multiple channels configured with trunking, because some VLANs in the chan-
nel have Port VLAN Cost values and the others have Port Cost values. This might not sound
useful (or meaningful), but it allows, for example, the configuration of VLAN traffic to load-
share between one EtherChannel connected to one core switch and another EtherChannel
connected to another core switch.

EtherChannel Configuration Guidelines


There are a host of guidelines for configuring EtherChannels. Figure 3-53 shows a Fast Ether-
Channel. The EtherChannel configuration guidelines relate to trunks, dynamic VLANs, STP,
and otherwise. If improperly configured, some EtherChannel interfaces are automatically dis-
abled to avoid network loops and other problems.
1439_CCNP_3.book Page 246 Wednesday, October 27, 2004 9:54 AM

246 Chapter 3: Spanning Tree Protocol (STP)

Figure 3-53 Fast EtherChannel Topology

Fast Fast
A EtherChannel EtherChannel D
Fast Ethernet 1

Fast Ethernet 2

B E

Fast Ethernet 3

Fast Ethernet 4
C F

To minimize time spent troubleshooting EtherChannel, adhere to the following recommendations:


■ Assign all ports in an EtherChannel to the same VLAN, or configure them as trunk
ports. If the EtherChannel is configured as a trunk, configure the same trunk mode on
all the ports in the EtherChannel. Configuring ports in an EtherChannel in different
trunk modes can have unexpected results. An EtherChannel supports the same allowed
range of VLANs on all the ports in a trunking EtherChannel. If the allowed range of
VLANs is not the same for a port list, the ports do not form an EtherChannel even
when set to auto or desirable mode.
■ Do not configure the ports in an EtherChannel as dynamic VLAN ports. Doing so can
adversely affect switch performance. An EtherChannel does not form with ports that
have different GARP, GVRP, or QoS configurations. GARP and GVRP are industry-
standard protocols described in IEEE 802.1p. If a broadcast limit is configured on the
ports, configure it as a percentage limit for the channeled ports. With a packets-per-sec-
ond broadcast limit, unicast packets might get dropped for 1 second when the broadcast
limit is exceeded.
■ An EtherChannel does not form with ports that have the port security feature enabled.
The port security feature cannot be enabled for ports in an EtherChannel. If Internet
Group Management Protocol (IGMP) multicast filtering is using one port in an Ether-
Channel, set the EtherChannel mode for both PAgP and LACP to off. No other mode
can be used.
■ An EtherChannel does not form if one of the ports is a Switched Port Analyzer (SPAN)
destination port. An EtherChannel does not form if protocol filtering is set differently
on any of the ports. Each EtherChannel can have up to eight compatibly configured
1439_CCNP_3.book Page 247 Wednesday, October 27, 2004 9:54 AM

EtherChannel 247

Ethernet interfaces. Configure all interfaces in an EtherChannel to operate at the same


speed and duplex modes.
■ Enable all interfaces in an EtherChannel. If an interface in an EtherChannel is shut
down, it is treated as a link failure, and its traffic is transferred to one of the remaining
interfaces in the EtherChannel.
■ Interfaces with different STP Port Costs can form an EtherChannel as long they are
otherwise compatibly configured. Setting different STP Port Costs does not, by itself,
make interfaces incompatible for the formation of an EtherChannel. However, it is pref-
erable to set STP Port Costs to be equal for all ports in an EtherChannel.
Beyond the restrictions listed here, the only remaining concern is what ports can be used
when configuring an EtherChannel. Catalyst 4000 and 6000 line cards have newer chipsets
that allow the use of an even or odd number of links in the EtherChannel. The ports do not
have to be contiguous or even on the same line card, as is true with some Catalyst devices
and line modules. The newer chips on the Catalyst 4000s and 6000s are not available on all
Catalyst hardware.
Older Catalyst switches use an Ethernet Bundle Controller (EBC) to manage aggregated
EtherChannel ports (for example, performing frame distribution). The EBC communicates
with the Enhanced Address Recognition Logic (EARL) application-specific integrated circuit
(ASIC). The EARL is responsible for, among other things, learning MAC addresses. For
example, the EARL ages out all addresses learned on a link in an EtherChannel bundle when
it fails. After a link failure, the EBC and the EARL work together to recalculate in hardware
the “lost” source-destination address pairs on a different link. On the older switches, when
selecting ports to group for an EtherChannel process, ports that belong to the same EBC must
be selected. A 24-port module has three groups of eight ports, and a 12-port module has three
groups of four ports, as shown in Figure 3-54.

Figure 3-54 Groups of Four or Eight Ports Are Managed by Ethernet Bundle Controllers on Older
Catalyst Switches

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3
1 1 1 1 2 2 2 2 3 3 3 3

Be sure to check the hardware documentation before attempting to create EtherChannel bun-
dles. Older Catalyst switches restrict which ports are used in a given bundle. The remainder
of the material in this section pertains primarily to Catalyst 5000 line modules.
1439_CCNP_3.book Page 248 Wednesday, October 27, 2004 9:54 AM

248 Chapter 3: Spanning Tree Protocol (STP)

In a 12-port module, up to two dual-segment EtherChannel configurations can be created


within each group of four ports, as illustrated in Example A in Table 3-34. One dual-segment
EtherChannel configuration can be created within each group, as shown in Example B.
Example C illustrates a four-segment and two-segment EtherChannel configuration.

Table 3-34 Some Combinations of Ports Are Invalid for EtherChannel Formation on Older Catalyst
Switches

Port 1 2 3 4 5 6 7 8 9 10 11 12

Example A OK 1 1 2 2 3 3 4 4 5 5 6 6

Example B OK 1 1 2 2 3 3
Example C OK 1 1 1 1 2 2

Example D Not OK 1 1

Example E Not OK 1 1 2 2 2 2

Example F Not OK 1 1

Example G Not OK 1 1

Some EtherChannel configurations must be avoided on older Catalyst devices, including


most Catalyst 5000 line cards. Example D illustrates an invalid two-segment EtherChannel
configuration using Ports 3 and 4 of a group. The EBC must start its bundling with the first
ports of a group. This does not mean that the first group has to be used. In contrast, a valid
dual-segment EtherChannel configuration can use Ports 5 and 6 with no EtherChannel seg-
ment on the first group. Example E illustrates another invalid configuration. In this example,
two EtherChannel segments are formed. One is a dual-segment EtherChannel configuration,
and the other is a four-segment EtherChannel configuration. The dual-segment EtherChannel
configuration is valid. The four-segment EtherChannel configuration, however, violates the
rule that all ports must belong to the same group (EBC). This EtherChannel configuration
uses two ports from the first group and two ports from the second group.
Finally, Example G is an invalid EtherChannel configuration because it does not use the first
ports on the module to start the EtherChannel process (like Example D). The EtherChannel
process cannot be started with middle ports on the line module. All the examples in Table 3-34
apply to 24-port modules as well. The only difference between 12- and 24-port modules is the
number of EtherChannel segments that can be formed within a group. The 12-port module
allows only two (two-port) EtherChannel segments in a group, whereas the 24-port module
supports up to four (two-port) EtherChannel segments per group.
1439_CCNP_3.book Page 249 Wednesday, October 27, 2004 9:54 AM

EtherChannel 249

Configuring Fast EtherChannel


To configure EtherChannel on an IOS-based switch, on each of the participating interfaces
(up to eight), enter the following command:
channel-group channel-group-number mode {auto [non-silent] | desirable
[non-silent] | on}

The channel-group command replaces the port group command, which was used before
Cisco IOS Release 12.1.
To remove an interface from the EtherChannel group, use the no channel-group interface
configuration command.
Example 3-2 demonstrates the configuration of EtherChannel on an IOS-based switch. A
shortcut is available, beginning with Cisco IOS Release 12.1(5)T. Identical commands can be
entered once for a range of interfaces, rather than being entered separately for each interface,
using the interface range command.

Example 3-2 A Gigabit EtherChannel Is Configured Just as a Fast EtherChannel Is Configured

Switch(config)#interface range gigabitethernet0/1 - 2


Switch(config-if)#channel-group 1 mode desirable

To verify the EtherChannel configuration and view EtherChannel information, use the fol-
lowing command:
show etherchannel [channel-group-number] {brief | detail | load-balance | port |
port-channel | summary}

Example 3-3 demonstrates some sample output from this command.

Example 3-3 The show etherchannel Command Replaces the Previous show port group Command

Switch#show etherchannel 1 summary

Flags: D - down P - in port-channel


I - stand-alone s - suspended
R - Layer3 S - Layer2
U - port-channel in use

Group Port-channel Ports


...................................................................
1 Po1(SU) Ci0/1(P) Gi0/2(P)
1439_CCNP_3.book Page 250 Wednesday, October 27, 2004 9:54 AM

250 Chapter 3: Spanning Tree Protocol (STP)

The show etherchannel command replaces the show port group command, which was used
before Cisco IOS Release 12.1.
To specify the technique for load distribution (frame distribution) among links comprising an
EtherChannel, use the following command:
port-channel load-balance {dst-mac | src-mac}

A sample configuration using this command would be as follows:


Switch(config)#port-channel load-balance dst-mac

Verify the configuration with the command show etherchannel load-balance. Finally, to
view PAgP status information, use the following command:
show pagp [channel-group-number] {counters | internal | neighbor}

Example 3-4 demonstrates some sample output from this command.

Example 3-4 Use the show pagp counters Command to View PAgP Status Information

Switch#show pagp counters

Information Flush
Port Sent Recv Sent Recv
.....................................................
Channel group: 1
Gi0/1 45 42 0 0
Gi0/2 45 41 0 0

Lab 3.10.5 Configuring Fast EtherChannel


In this lab exercise, you provide more bandwidth between Ethernet switches. You
combine two 100-Mbps links to form a full-duplex 200-Mbps link.

Summary
This chapter discussed Layer 2 techniques and technologies designed to optimize network
reliability, resiliency, and redundancy within a campus network.
In particular, this chapter explored
■ The importance of STP as a key Layer 2 network protocol
■ Scaling issues with STP as they pertain to VLANs
1439_CCNP_3.book Page 251 Wednesday, October 27, 2004 9:54 AM

Summary 251

STP enables Layer 2 reliability, resiliency, and redundancy in a campus network. STP
dynamically configures a Layer 2 topology that blocks physical loops in a switched network
while at the same time providing a number of configuration options for tailoring the flow of
traffic in a network.
A Root Switch serves as the focal point of the topology for each VLAN configured in PVST+
STP mode. With Path Cost, Port Priority, Bridge Priority, STP timers, PortFast, UplinkFast,
and BackboneFast, the tools are available to design a robust Layer 2 topology.
EtherChannel provides the finishing touch to the Layer 2 switched infrastructure. EtherChannel
provides for incremental bandwidth Ethernet link options, ranging from 10 Mbps (half-duplex)
100-m links to 160 Gbps (full-duplex) 70-km links. EtherChannel relies on PAgP to dynami-
cally manage bundles of Ethernet links.
Several protocols are important for Layer 2 switched design and deployment. This chapter
focused on STP and PAgP.
1439_CCNP_3.book Page 252 Wednesday, October 27, 2004 9:54 AM

252 Chapter 3: Spanning Tree Protocol (STP)

Key Terms
BackboneFast A Catalyst feature that is initiated when a Root Port or Blocked Port on a
switch receives inferior BPDUs from its Designated Bridge. Max Age is skipped to allow
appropriate Blocked Ports to transition quickly to Forwarding state in the case of an indirect
link failure.
Blocking state The STP state in which a bridge listens for BPDUs. This state follows the
Disabled state.
Bridge ID (BID) An 8-byte field consisting of an ordered pair of numbers—a 2-byte decimal
number called the Bridge Priority and a 6-byte (hexadecimal) MAC address.
Bridge Priority A decimal number used to measure the preference of a bridge in the
Spanning Tree Algorithm. The possible values range between 0 and 65,535.
Bridge Protocol Data Unit (BPDU) A frame used by switches and bridges to communicate
spanning-tree information.
Common Spanning Tree (CST) A spanning-tree implementation specified in the IEEE
802.1Q standard. CST defines a single instance of spanning tree for all VLANs with BPDUs
transmitted over VLAN 1.
Designated Bridge The Designated Bridge for a segment is the bridge containing the
Designated Port for that segment.
Designated Port The Designated Port for a segment is the bridge port connected to the seg-
ment that both sends traffic toward the Root Switch and receives traffic from the Root Switch
over that segment.
Disabled state The administratively shut-down STP state.
edge port With RSTP, an edge port is functionally equivalent to a port configured with
PortFast under PVST+. An edge port immediately transitions to the Forwarding state. An
edge port should be configured only on ports that connect to a single end station.
EtherChannel A Cisco-proprietary technology that, by aggregating links into a single logical
link, provides incremental trunk speeds ranging from 100 Mbps to 160 Gbps.
forward delay How much time the bridge spends in the Listening and Learning states.
Forwarding state The STP state in which data traffic is both sent and received on a port. It
is the last STP state, following the Learning state.
hello time The time interval between the sending of Configuration BPDUs.
1439_CCNP_3.book Page 253 Wednesday, October 27, 2004 9:54 AM

Key Terms 253

Learning state The STP state in which the bridge does not pass user data frames but builds
the bridging table and gathers information, such as the source VLANs of data frames. This
state follows the Listening state.
Link Aggregation Control Protocol (LACP) Allows Cisco switches to manage Ethernet
channels with non-Cisco devices conforming to the 802.3ad specification. Defined in IEEE
802.3ad.
Listening state The STP state in which no user data is passed, but the port sends and
receives BPDUs in an effort to determine the active topology. It is during the Listening state
that the three initial convergence steps take place—elect a Root Switch, elect Root Ports, and
elect Designated Ports. This state follows the Blocking state.
Max Age An STP timer that controls how long a bridge stores a BPDU before discarding it.
The default is 20 seconds.
Mono Spanning Tree (MST) The spanning-tree implementation used by non-Cisco
802.1Q switches. One instance of STP is responsible for all VLAN traffic.
Multiple Instances of Spanning Tree Protocol (MISTP) Lets you group multiple VLANs
under a single instance of spanning tree. MISTP combines the Layer 2 load-balancing bene-
fits of PVST+ with the lower CPU load of IEEE 802.1Q.
Multiple Spanning Tree (MST) Extends the IEEE 802.1w Rapid Spanning Tree (RST)
algorithm to multiple spanning trees, as opposed to the single CST of the original IEEE
802.1Q specification. This extension provides for both rapid convergence and load sharing
in a VLAN environment.
Path Cost An STP measure of how close bridges are to each other. Path Cost is the sum of
the costs of the links in a path between two bridges.
Per-VLAN Spanning Tree (PVST) A Cisco-proprietary spanning-tree implementation
requiring ISL trunk encapsulation. PVST runs a separate instance of STP for each VLAN.
PortFast A Catalyst feature that, when enabled, causes an access or trunk port to enter the
spanning-tree Forwarding state immediately, bypassing the Listening and Learning states.
Port Aggregation Protocol (PAgP) A Cisco-proprietary technology that facilitates the auto-
matic creation of EtherChannels by exchanging packets between Ethernet interfaces.
Port ID A 2-byte STP parameter consisting of an ordered pair of numbers—the Port Prior-
ity and the Port Number.
Port Number A numerical identifier used by Catalyst switches to enumerate the ports.
1439_CCNP_3.book Page 254 Wednesday, October 27, 2004 9:54 AM

254 Chapter 3: Spanning Tree Protocol (STP)

Port Priority A configurable STP parameter with values ranging from 0 to 63 on a CatOS
switch (the default is 32) and from 0 to 255 on an IOS-based switch (the default is 128). Port
Priority is used to influence Root Switch selection when all other STP parameters are equal.
PVST+ A Cisco-proprietary implementation that allows CST and PVST to exist on the
same network.
Rapid Spanning Tree Protocol (RSTP) An evolution of STP (802.1D standard) that
provides for faster spanning-tree convergence after a topology change. The standard also
includes features equivalent to Cisco PortFast, UplinkFast, and BackboneFast for faster
network reconvergence.
Root Bridge The bridge/switch with the lowest Bridge ID for that VLAN. Each VLAN has
a Root Bridge. Also called the Root Switch.
Root Path Cost The cumulative cost of all links to the Root Switch.
Root Port A port on a bridge closest to the Root Switch in terms of Path Cost.
Root Switch See Root Bridge.
Spanning Tree Protocol (STP) A Layer 2 protocol that uses a special-purpose algorithm to
discover physical loops in a network and effect a logical loop-free topology.
UplinkFast A Catalyst feature that accelerates the choice of a new Root Port when a link or
switch fails.

Check Your Understanding


Use the following review questions to test your understanding of the concepts covered in this
chapter. Answers are listed in Appendix A, “Check Your Understanding Answer Key.”
1. Which of the following is used in Root Switch election?

A. Port ID

B. Path Cost

C. BID

D. Port Priority
2. What are the three steps of STP convergence?

A. Elect a Root Switch

B. Elect Designated Ports

C. Elect Blocking Ports

D. Elect Root Ports


1439_CCNP_3.book Page 255 Wednesday, October 27, 2004 9:54 AM

Check Your Understanding 255

3. On an IOS-based switch, the Port ID is a 16-bit ordered pair composed of what two val-
ues?
A. Port Preference

B. Port Priority

C. Port Number

D. Port Cost
4. The BID is an 8-byte ordered pair composed of what two values?

A. Bridge Priority

B. Bridge Preference

C. Bridge Number

D. MAC Address
5. Every active trunk port on the Root Switch is which of the following?

A. Root Port

B. Non-Designated Port

C. Designated Port

D. Blocking Port
6. Which of the following are IEEE 802.1D spanning-tree states?

A. Blocking

B. Discarding

C. Learning

D. Forwarding

E. Listening
7. Which of the following are IEEE 802.1w spanning-tree states?

A. Blocking

B. Listening

C. Learning

D. Forwarding

E. Discarding
1439_CCNP_3.book Page 256 Wednesday, October 27, 2004 9:54 AM

256 Chapter 3: Spanning Tree Protocol (STP)

8. Multiple Spanning Tree is specified by which IEEE standard?

A. 802.1D

B. 802.1w

C. 802.1Q

D. 802.1s
9. Which of the following spanning-tree parameters can be used to enable load sharing?

A. Port Priority

B. Bridge Priority

C. EtherChannel

D. Path Cost
10. Which of the following are the two protocols used to create Ethernet channels or
bundles?
A. LACP

B. VQP

C. DTP

D. PAgP
1439_CCNP_3.book Page 257 Wednesday, October 27, 2004 9:54 AM
1439_CCNP_3.book Page 258 Monday, November 1, 2004 11:16 AM

Objectives
After completing this chapter, you will be able to perform tasks related to the following:
■ Explain the role of each type of VLAN.
■ Understand the methods of routing between VLANs: adding a route processor to a
switch by way of a daughter card or module, using router-on-a-stick, using one router-
to-switch link per VLAN, and using fixed-chassis (nonmodular) multilayer switches.
■ Understand the advantages and disadvantages of each inter-VLAN routing method.
■ Configure inter-VLAN routing using each inter-VLAN routing method, with emphasis
on switch virtual interfaces and routed ports.
■ Troubleshoot inter-VLAN routing.
1439_CCNP_3.book Page 259 Wednesday, October 27, 2004 9:54 AM

Chapter 4

Inter-VLAN Routing
Configuring virtual LANs (VLANs) helps you control the size of broadcast domains and keeps
local traffic local. The downside of this benefit is that devices in different VLANs are unable to
communicate without the presence of some form of Layer 3 routing.
This chapter focuses on the alternative inter-VLAN routing solutions that may be used within
Layer 2 switched environments.

Methods of Inter-VLAN Routing


Over the years, the methods of routing traffic between VLANs have changed. The method is
dependent on the particular Catalyst switch platforms and the version of the operating system.
Basically, the evolution has gone from requiring a one-to-one mapping of switch ports to router
ports (one per VLAN), to router-on-a-stick (one switch port trunked to one router port populated
with subinterfaces—one per VLAN), and finally to routing via switch virtual interfaces on the
Catalyst switch. Also, not too long ago, the ability to configure switch ports as Layer 3 inter-
faces, totally independent of any VLAN association, became available on switches such as the
Catalyst 3550 and 6500.

Key Components of Inter-VLAN Routing


To provide routing between VLANs, three key components must be present:
■ A VLAN-capable switch
■ A router
■ Some form of connectivity between the switch and the router
Figure 4-1 illustrates a legacy method of inter-VLAN routing.
1439_CCNP_3.book Page 260 Wednesday, October 27, 2004 9:54 AM

260 Chapter 4: Inter-VLAN Routing

Figure 4-1 The First Form of Inter-VLAN Routing Required a Separate Physical Connection
Between the Layer 2 Switch and the Router for Each VLAN

VLAN 10 VLAN 20 VLAN 30

The router can be an external standalone unit, or it can be integrated within the switch hard-
ware. Common names used to describe routers that are integrated within the switch itself
include
■ Route Switch Module
■ Route Processor
■ Route Switch Processor
■ Route Switch Feature Card (RSFC)
■ Multilayer Switch Module (MSM)
■ Multilayer Switch Feature Card
■ Layer 3 Services Module
Or, the switch is simply called a Layer 3 switch.
If an external router is employed to perform inter-VLAN routing, connection to the switch
can be via a separate Ethernet/Fast Ethernet/Gigabit Ethernet link for each VLAN, or a single
trunking link can be used. Figure 4-2 illustrates the single-trunk option.
Layer 3 switches integrate the route processor within the switch itself, either in the form of
a daughter card or module added to a chassis-based (modular) switch or in the form of an
embedded processor in a nonmodular switch, as shown in Figure 4-3. The Catalyst 6509
switch with an MSFC2 daughter card is an example of a chassis-based switch with a route
processor added by way of a daughter card. The Catalyst 3550-24 switch is an example of a
nonmodular switch with an embedded route processor.
1439_CCNP_3.book Page 261 Wednesday, October 27, 2004 9:54 AM

Methods of Inter-VLAN Routing 261

Figure 4-2 The Second Generation of Inter-VLAN Routing Was Implemented by Connecting a
Layer 2 Switch to a Router with a Trunk Link

VLAN 10

VLAN 20

VLAN 30
k n
Tru

Figure 4-3 The Third Generation of Inter-VLAN Routing Came in the Form of Route Processors
Integrated Within the Switches

Layer 3 Switch

Internal Route
Processor
VLAN 10

VLAN 20

VLAN 30

The brains of a newly purchased chassis-based Catalyst switch, called the Supervisor Engine,
now come with embedded route processors, so it is no longer necessary to purchase separate
daughter cards or modules to add Layer 3 switching functionality. Examples of these are the
Supervisor Engine III and IV used with the Catalyst 4500 series switches and the Supervisor
Engine 720 used with the Catalyst 6500 switches.
1439_CCNP_3.book Page 262 Wednesday, October 27, 2004 9:54 AM

262 Chapter 4: Inter-VLAN Routing

Comparison of Layer 2 and Layer 3 Operations in the Core


The core is a crucial component of every network. Failure of a core device or link can isolate
large sections of a network from one another. For this reason, both core links and devices
should be designed with adequate redundancy.
In a LAN environment, it is possible to implement the core as a switched or routed layer.
Although both methods provide redundancy, they differ significantly in operation.
The Layer 2 or switched core manages its redundant links using Spanning Tree Protocol (STP),
as shown in Figure 4-4. This means that some links are not used because one or more ports
are in a blocking state. Not only does this underutilize the available bandwidth, but it also
often results in inefficient traffic paths.

Figure 4-4 Spanning Tree Protocol Handles Redundant Connections in a Switched Core

STP
Blocked

A routing protocol is used to manage redundant links in a routed core, as shown in Figure 4-5.
The routing protocol can select the optimal path for traffic and can make use of redundant
links through load balancing. Furthermore, implementing the core using Layer 3 allows more
flexibility and control over packet flows, permitting additional benefits, such as quality of
service (QoS), to be implemented.
1439_CCNP_3.book Page 263 Wednesday, October 27, 2004 9:54 AM

Methods of Inter-VLAN Routing 263

Figure 4-5 A Routing Protocol Is Used in a Routed Core to Handle Redundant Connections

Optimal Path Selected by


Routing Protocol

Inter-VLAN Routing Performance and Scalability Issues


For networks with just a couple of VLANs, using a physical interface for each VLAN can be
a viable inter-VLAN routing strategy, as shown in Figure 4-6.

Figure 4-6 The One-Link-Per-VLAN Inter-VLAN Routing Method Theoretically Could Still Be Used in
a Network with Only a Few Data VLANs

VLAN 10 VLAN 20 VLAN 30


1439_CCNP_3.book Page 264 Wednesday, October 27, 2004 9:54 AM

264 Chapter 4: Inter-VLAN Routing

For networks with more than a few VLANs, however, a routing strategy that uses virtual
interfaces becomes a must. Both an external and internal router can be used with subinterfaces.
The difference between the two solutions involves a trade-off between cost and performance.
An entry-level external router is generally cheaper than a switch with Layer 3 functionality,
but the lack of integration between the Layer 2 and Layer 3 elements of the network and the
“up and back” nature of external routers limit performance, as shown in Figure 4-7. As soon
as the 100-Mbps capacity of the external router’s link is exceeded, the use of an integrated
route processor becomes the only realistic option for providing inter-VLAN routing, as
shown in Figure 4-8.

Figure 4-7 The Bandwidth of the Trunk Link Between a Router and a Layer 2 Switch Is One
Limitation of the Second-Generation Inter-VLAN Routing Method
k n
Tru

Sending Traffic Receiving Traffic

Figure 4-8 An Integrated Route Processor Is the Ideal Solution for Inter-VLAN Routing

Layer 3 Switch

Internal Route
Processor
VLAN 10

VLAN 20

VLAN 30

Internal Links
1439_CCNP_3.book Page 265 Wednesday, October 27, 2004 9:54 AM

Methods of Inter-VLAN Routing 265

Regardless of the routing technique chosen, it is essential that the switched elements of the
access and distribution layer be aligned with the routing functionality at the distribution layer.
In particular, you should ensure that the distribution switch is the root of the spanning tree for
each VLAN that is routed by the distribution router. This step is easily overlooked. Although
a network will provide connectivity with an access layer switch acting as the STP root, the
inefficient traffic flow will seriously limit the throughput of the distribution layer links.

Roles of the Different Types of VLANs


Various types of VLANS exist:
■ VLAN 1
■ The default VLAN
■ The user VLANs
■ The native VLAN
■ The management VLAN
By default, all Ethernet interfaces on Cisco switches are on VLAN 1. On Catalyst switches,
all the VLAN types in the preceding list default to VLAN 1, which can add to the difficulty of
understanding their differences. This section explains the various types of VLANS to clear up
some of the confusion.

VLAN 1
The reason VLAN 1 became a special VLAN is that Layer 2 devices needed to have a default
VLAN to assign to their ports, including their management port(s). In addition, many Layer 2
protocols, such as Bridge Protocol Data Unit (BPDU), Cisco Discovery Protocol (CDP),
VLAN Trunking Protocol (VTP), Port Aggregation Protocol (PAgP), and Dynamic Trunking
Protocol (DTP), needed to be sent on a specific VLAN on trunk links. For all these reasons,
VLAN 1 was chosen. Figure 4-9 illustrates that the control traffic is associated with VLAN 1.
BPDU, CDP, VTP, PAgP, and DTP are always transmitted over VLAN 1. This is always the
case and cannot be changed. Cisco recommends that VLAN 1 be used only for these proto-
cols. The management VLAN and user VLANs should all be configured to use VLANs other
than VLAN 1.
1439_CCNP_3.book Page 266 Wednesday, October 27, 2004 9:54 AM

266 Chapter 4: Inter-VLAN Routing

Figure 4-9 The Default VLAN (VLAN 1), the User VLANs, the Native VLAN, and the Management
VLAN Are All Important Considerations in Network Design

VLAN Trunk
VLAN 1 - Native VLAN, Untagged

CDP, VTP, PAgP, DTP

User VLAN 10 - Tagged

172.16.10.0/24

User VLAN 20 - Tagged

172.16.20.0/24

Management VLAN 99 - Tagged

172.16.99.0/24

Default VLAN
By default, VLAN 1 is also the VLAN assigned to all switch ports (unless configured other-
wise). VLAN 1 is also known as the default VLAN because all switch ports are in VLAN 1
when the switch boots with a clean configuration and vlan.dat file. It is possible to artificially
change the default VLAN upon initial switch configuration by configuring all ports on the
switch to be members of a particular VLAN other than VLAN 1. However, the Catalyst
switch show vlan output will still display VLAN 1 as the default VLAN. The other types of
VLANs—the native VLAN, the management VLAN, and the user VLANs—are all automati-
cally members of the default VLAN unless specifically configured otherwise (see Figure 4-9).
All Ethernet interfaces on Catalyst switches default to VLAN 1. Any device connected to an
interface on a switch is a member of VLAN 1 unless that interface is configured to use a dif-
ferent VLAN with the switchport access vlan interface command.

User VLANs
User VLANs are typically what people think of when referring to VLANs. A user VLAN is
created to segment a group of users, either geographically or logically, from the rest of the
network (see Figure 4-9). The switchport access vlan interface command is used to assign
interfaces to these various user VLANs.
1439_CCNP_3.book Page 267 Wednesday, October 27, 2004 9:54 AM

Methods of Inter-VLAN Routing 267

Native VLAN
A topic that causes considerable confusion is the native VLAN. Native VLAN is a term used
with interfaces that are configured as VLAN trunks. When a switch port is configured as a
trunk, it tags frames with the appropriate VLAN number. Frames from all VLANs are carried
across the trunk link containing the 802.1Q tag, except for frames belonging to the native
VLAN. With factory defaults on a Catalyst switch, frames from VLAN 1 belong to the native
VLAN and are carried across the trunk untagged. Figure 4-9 illustrates this default associa-
tion between the native VLAN and VLAN 1.
The IEEE committee that defined 802.1Q decided that, for backward compatibility, it was
desirable to associate all untagged traffic on an 802.1Q link with a specific VLAN. This
VLAN is the native VLAN and is implicitly used for all the untagged traffic received on an
802.1Q-capable port. This capability is desirable because it allows 802.1Q-capable ports
to talk to old 802.3 ports directly by sending and receiving untagged traffic. However, in
all other cases, leaving traffic untagged might be very detrimental. For example, identity
enforcement and class of service (802.1p) bits are lost when untagged frames are transmitted
over an 802.1Q link.
For these reasons—loss of means of identification and loss of classification—you should
avoid the use of the native VLAN for data traffic. There are very few reasons why the native
VLAN would ever need to be used explicitly for traffic.
The native VLAN can be modified to be a VLAN other than VLAN 1 with the switchport
trunk native vlan vlan-id interface command.
The recommended practice is that the native VLAN should never be used as a user VLAN or
the management VLAN.
As stated in the section “VLAN 1,” control traffic—CDP, VTP, PAgP, and DTP—is transmit-
ted over VLAN 1, which is the default native VLAN. If the native VLAN is changed to some-
thing other than VLAN 1, the control traffic is transmitted on VLAN 1 as tagged traffic. This
has no ill effects on the control traffic.
It is fine to leave VLAN 1 as the default native VLAN, as long as it is not used as a user
VLAN or as the management VLAN. Control traffic should be the only information carried
across VLAN 1. However, common practice is to change the native VLAN to a dummy VLAN
(other than VLAN 1) that is not used for any data or management traffic. Figure 4-10 illus-
trates this, with VLAN 2 configured as the native VLAN.
1439_CCNP_3.book Page 268 Wednesday, October 27, 2004 9:54 AM

268 Chapter 4: Inter-VLAN Routing

Figure 4-10 Common Practice Is to Create a Dummy VLAN to Be Used As the Native VLAN for
IEEE 802.1Q Trunks

VLAN Trunk
VLAN 1 - Tagged
CDP, VTP, PAgP, DTP
VLAN 2 - Untagged
Native VLAN
User VLAN 10 - Tagged
172.16.10.0/24
User VLAN 20 - Tagged
172.16.20.0/24
Management VLAN 99 - Tagged
172.16.99.0/24

It’s important to ensure that both ends of a switch-to-switch link have consistent native
VLANs configured. If the native VLANs on both ends of a link are not the same, there will
effectively be a bridge between them, and they will no longer be independent broadcast
domains. Fortunately, recent versions of Cisco IOS software alert the user when mismatches
in the native VLAN occur.

Management VLAN
Most of today’s switches and routers can be accessed remotely via Telnet or SSH to the
device’s management Internet Protocol (IP) address. The recommended practice is to put
these and other networking devices in their own VLAN, known as the management VLAN.
The management VLAN should be a separate VLAN, independent of any user VLANs, inde-
pendent of the native VLAN, and independent of VLAN 1. In case network problems occur,
such as broadcast storms or spanning-tree convergence issues, an independent management
VLAN still allows the network administrator to access these devices and troubleshoot the
problem. In Figure 4-9, the management VLAN is configured as VLAN 99.
Another reason to keep the management VLAN independent of user VLANs is that it keeps
“trusted devices” separate from “untrusted devices.” This lessens the possibility, either by
misconfiguration, accident, or intent, that users gain access to the routers or switches.
1439_CCNP_3.book Page 269 Wednesday, October 27, 2004 9:54 AM

Methods of Inter-VLAN Routing 269

Configuring the Router with a Native VLAN


When a router’s interface is configured as a trunk link, frames received on that interface from
the native VLAN on the switch enter the interface untagged. Frames from the other nonnative
VLANs enter the interface tagged as Inter-Switch Link (ISL) or 802.1Q.
Configuring the router’s interface as a trunk link requires the use of subinterfaces. Each
VLAN is configured on a separate subinterface. Each subinterface is configured to match the
proper trunking protocol on the switch, 802.1Q or ISL using the encapsulation [dot1q | isl]
vlan-id router interface command.
However, the router’s subinterface that receives the native VLAN traffic must be configured
to expect those frames to be untagged. This is done using the native option of the encapsula-
tion dot1q vlan-id [native] subinterface command. Note that the native option is unavailable
when you perform ISL trunking—it is unique to IEEE 802.1Q trunking.
Before Cisco IOS software Release 12.1(3)T, the router had to be configured with the native
VLAN on the physical interface, and nonnative VLANs were configured on the subinterface
with the ISL or 802.1Q tag.

Summary of VLAN Types


The following list summarizes the different VLANs and how they should be used:
■ By default, VLAN 1 is the native VLAN and should only be used to carry control
traffic, such as CDP, VTP, PAgP, and DTP. This information is transmitted across trunk
links untagged.
■ User VLANs should not include the native VLAN. VLAN 1 is the native VLAN unless
this is changed. User VLAN traffic is sent as tagged frames across VLAN trunks.
■ The management VLAN should be separate from the user VLANs. It should not be the
native VLAN, and it should not be VLAN 1. This ensures access to networking devices
in case of problems with the network.
■ The subinterface on the router that is used to send and receive native VLAN traffic must
be configured with the native option of the encapsulation interface command. Doing
so lets the router know that any frames coming in untagged belong to that subinterface
and are members of the native VLAN.

Route Switch Processors


The highest-performing inter-VLAN routing option uses an internal route switch processor.
Figure 4-11 shows one type of route switch processor. In the case of a modular switch, the
route switch processor resides on a router card that is plugged into the switch. On some
switch platforms, the route switch processor is not modular but is an integral part of the
switch hardware architecture.
1439_CCNP_3.book Page 270 Wednesday, October 27, 2004 9:54 AM

270 Chapter 4: Inter-VLAN Routing

Figure 4-11 Catalyst 4500 and 6500 Switches Provide Layer 3 Switching if the Appropriate Module
Is Inserted in the Chassis

Integrated route switch processors perform better than external routers for the following
reasons:
■ The router’s CPU power is well matched to the switch’s capacity.
■ The router has direct access to the switch’s backplane. This offers more bandwidth than
a physical interface.
■ The router is highly integrated within the switch. This allows high-speed routing fea-
tures such as Cisco Express Forwarding (CEF) to be implemented easily.
In addition to the route switch processor’s high-speed routing performance, there can also be
significant benefits in terms of ease of configuration and management. For most Catalyst
switches, the route switch processor’s interfaces are actually specified as VLAN interfaces.
For example, Example 4-1 shows the commands needed to configure an IP address for the
router’s interface in VLAN 55.

Example 4-1 Integrated Route Processors Make It Easy to Configure Inter-VLAN Routing

Switch(config)#interface vlan 55
Switch(config-if)#ip address 10.0.1.1 255.255.255.0

This ease of configuration and management makes it difficult to mismatch router interfaces
and VLAN IDs and produces Layer 2 and Layer 3 configuration files that are easier to inter-
pret than when an external router is used.
1439_CCNP_3.book Page 271 Wednesday, October 27, 2004 9:54 AM

Methods of Inter-VLAN Routing 271

Router-on-a-Stick
The technique of implementing inter-VLAN routing using a single trunk-connected Fast
Ethernet link to a router is called router-on-a-stick (see Figure 4-12).

Figure 4-12 Router-on-a-Stick Uses a Layer 2 Switch and an External Router Connected with an ISL
or IEEE 802.1Q Trunk

VLAN 20
VLAN 10 192.168.2.0
192.168.1.0

Trunk VLAN 30
192.168.3.0

Physical Interface
FastEthernet 0/0
Logical Interface
FastEthernet 0/0.10
IP Address 192.168.1.1
Logical Interface
FastEthernet 0/0.20
IP Address 192.168.2.1

Logical Interface
FastEthernet 0/0.30
IP Address 192.168.3.1

The primary advantage of using a trunk link is a reduction in router and switch ports. Doing
so not only saves money but also can reduce configuration complexity. Consequently, the
trunk-connected router approach can scale to a much larger number of VLANs than a one-
link-per-VLAN design. The number of subinterfaces on a router interface can easily accom-
modate the maximum number of VLANs on the connected Layer 2 switch. The Catalyst
2950T switch with the enhanced image, for example, supports up to 4094 VLANs.
However, the trunk-connected router configuration has disadvantages, including the following:
■ There is a possibility of inadequate bandwidth for each VLAN.
■ Additional overhead on the router can occur.
■ Older versions of Cisco IOS software support only a limited set of features on trunked
interfaces and might support only Cisco’s proprietary ISL trunking encapsulation.
■ Trunking is not supported on most Cisco routers with standard Ethernet interfaces and
some lower-end routers with Fast Ethernet interfaces.
1439_CCNP_3.book Page 272 Wednesday, October 27, 2004 9:54 AM

272 Chapter 4: Inter-VLAN Routing

With regard to inadequate bandwidth for each VLAN, consider the situation in which all
VLANs must share the Fast Ethernet 100 Mbps of bandwidth. A single VLAN could easily
consume the entire capacity of the router or link, especially in the event of a broadcast storm
or spanning-tree problem. Furthermore, the up-and-back nature of router-on-a-stick designs
effectively doubles the link’s bandwidth consumption (see Figure 4-12).
With regard to the additional overhead on the router caused by using a trunk-connected
router, not only must the router perform normal routing and data-forwarding duties, it also
must handle the additional encapsulation used by the trunking protocol.

When to Use the Router-on-a-Stick Design


In general, the router-on-a-stick approach to inter-VLAN routing is most appropriate when
other options using internal route processors are unavailable. Internal route processors include
Route Switch Modules (RSMs) and Multilayer Switch Feature Cards (MSFCs). The router-
on-a-stick design is not necessarily a poor choice; however, other options tend to provide
higher throughput and functionality. Also, because the router-on-a-stick technique functions
as if the router were sitting on the edge of the network (at least as far as the Layer 2 network
is concerned), it tends to be less tightly integrated with the rest of the campus network, as
illustrated in Figure 4-13. Newer approaches, employing embedded route processors, seek to
place routing in the middle of the network, where it can have a greater influence on the net-
work’s overall scalability and stability.

Figure 4-13 The Router-on-a-Stick Technique Functions As If the Router Were Sitting on the Edge
of the Network

802.1Q
Trunk

802.1Q 802.1Q
Trunk Trunk

802.1Q
Trunk
1439_CCNP_3.book Page 273 Wednesday, October 27, 2004 9:54 AM

Methods of Inter-VLAN Routing 273

Cisco Layer 3 Feature Cards


Although the performance of route switch processors generally is adequate for typical appli-
cations, circumstances exist in which additional performance is required. Here are some situ-
ations that might require additional routing performance:
■ A high proportion of traffic needs to cross VLAN boundaries. 80 percent is a figure that
approximates this type of traffic in modern switched networks.
■ A large number of interfaces are present, say 100 or more, and many are 1 Gbps or
greater in speed.
■ Additional switching capacity has been provided through the addition of a Switch Fab-
ric Module on a Catalyst 6500.
Two Layer 3 feature cards available for the Catalyst 6500 Series switches are the MSFC,
shown in Figure 4-14, and the Policy Feature Card (PFC), shown in Figure 4-15.

Figure 4-14 The MSFC Is the Daughter Card on the Left Side of the Supervisor Engine

MSFC

The MSFC provides Layer 3 functionality and enables the use of CEF for increased routing
performance.
The PFC contains the application-specific integrated circuits (ASICs) for Layer 2 and Layer 3
lookups and performs many Cisco IOS features in hardware. The PFC performs IP Unicast
and Multicast forwarding, QoS, and access control list (ACL) lookups in hardware. The PFC
scales central forwarding to 30 Mbps.
1439_CCNP_3.book Page 274 Wednesday, October 27, 2004 9:54 AM

274 Chapter 4: Inter-VLAN Routing

Figure 4-15 The PFC Is the Daughter Card on the Right Side of the Supervisor Engine
PFC

Configuring Inter-VLAN Routing


The following four sections examine the configuration required to implement inter-VLAN
routing on a Catalyst 3550 or 3750 switch. In all the examples, the first task should always be
to turn on IP routing functionality with the ip routing global configuration command. The
next sections detail inter-VLAN routing involving the following:
■ Switch virtual interfaces
■ Routed ports
■ External router and internal route processor
■ Routing between an external router and an internal route processor

Configuring Inter-VLAN Routing in a Switched Network


Catalyst 3550, 3750, 4000, 4500, 5000, 5500, 6000, and 6500 series switches all can perform
inter-VLAN routing. The Catalyst 3550 and 3750 series switches provide fixed-chassis solutions
for inter-VLAN routing, without the capability to add line cards for increasing port density.
All Cisco routers with Fast Ethernet interfaces, except the 1720 router, can support router-
on-a-stick functionality. The router-on-a-stick solution is used if the distribution switches do
not include an internal route processor. Cisco 2900XL, 2950, and 3500XL switches are
examples of Layer 2 switches, which do not include route processors.

Configuring Inter-VLAN Routing Via the Switch Virtual Interface


By far the most common method of achieving inter-VLAN routing is to configure the switch
virtual interface. Using this technique, the router has a virtual interface in every VLAN
1439_CCNP_3.book Page 275 Wednesday, October 27, 2004 9:54 AM

Configuring Inter-VLAN Routing 275

created on the switch. Rather than configuring a physical interface for each VLAN, the router
uses a virtual or VLAN interface. For example, the commands shown in Example 4-2 allow
the router to route traffic to and from VLAN 55.

Example 4-2 Switch Virtual Interfaces Are Used to Configure Inter-VLAN Routing on IOS-Based Layer 3 Catalyst
Switches

Switch(config)#interface vlan 55
Switch(config-if)#ip address 10.0.1.1 255.255.255.0

These commands have the same effect as if a physical router interface were connected to a
switch port in the appropriate VLAN.
Following the configuration of the IP address, the no shutdown interface command is
required when configuring interface VLAN 1. The interface is shut down by default.

Lab 4.3.2 Inter-VLAN Routing with the Internal Route Processor


In this lab exercise, you configure inter-VLAN routing using a switch with an
internal route processor.

Configuring Inter-VLAN Routing Via the Routed Port


Although it is more common to configure inter-VLAN routing using the virtual (VLAN)
interface, it is also possible to configure a physical switch port/interface as a router interface.
Through this process, it is possible to turn a 12- or 24-port multilayer Ethernet switch into a
12- or 24-interface Ethernet router.
Turning a switch port into a router interface is simply a matter of turning off the switch port
functionality, as shown in Example 4-3.

Example 4-3 Routed Ports Are Used to Configure Layer 3 Catalyst Switch Ports as Router Interfaces

Switch(config)#interface fa0/1
Switch(config-if)#no switchport
Switch(config-if)#ip address 10.0.1.1 255.255.255.0

As soon as the Layer 2 functionality is turned off, the interface can be treated as though it is
a regular Fast Ethernet router interface. For example, an IP address can be configured. The
switch port can now be used as a physical router port for connection to external devices.
1439_CCNP_3.book Page 276 Wednesday, October 27, 2004 9:54 AM

276 Chapter 4: Inter-VLAN Routing

Configuring Routing Between an External Router and an Internal


Route Processor
Connecting an external router to an internal route switch processor is often necessary (see
Figure 4-16). A common reason for this is to provide access to a WAN interface, because
these often are not provided on a switch.

Figure 4-16 A Multilayer Switch Can Obtain WAN Connectivity Through a Routed Link Connection
to an External Router

WAN

s 0/0

Routed Port
fa 0/1 fa 0/0

External
Router

The easiest method of implementing this is to create a routed port, as shown in Example 4-4.

Example 4-4 A Routed Link Can Be Configured Between a Multilayer Switch Port, Configured as a Routed Port,
and an External Router

RouteSwitch(config)#interface fa 0/1
RouteSwitch(config-if)#no switchport
RouteSwitch(config-if)#ip address 10.0.1.1 255.255.255.0

ExtRouter(config)#interface fa 0/0
ExtRouter(config-if)#ip address 10.0.1.2 255.255.255.0

Although a routed port is configured for connectivity with an external router, inter-VLAN
routing would most likely be achieved through the use of switch virtual interfaces.
To route between VLANs 10 and 20, which have been configured on the multilayer switch,
use the configuration shown in Example 4-5.
1439_CCNP_3.book Page 277 Wednesday, October 27, 2004 9:54 AM

Configuring Inter-VLAN Routing 277

Example 4-5 Inter-VLAN Routing with Switch Virtual Interfaces Can Be Coupled with Routing Over a Routed
Link Between a Switch Port on a Multilayer Switch Configured as a Routed Port and a Router Interface on an Exter-
nal Router

RouteSwitch(config)#interface vlan 10
RouteSwitch(config-if)#ip address 10.0.10.1 255.255.255.0
RouteSwitch(config)#interface vlan 20
RouteSwitch(config-if)#ip address 10.0.20.1 255.255.255.0

The internal route processor on the switch most likely will need to run a dynamic routing pro-
tocol and perhaps include some static routes. If there are network segments that are not
directly connected to the switch, a dynamic routing protocol or static routes are required.

Lab 4.3.3 Routing Between an External Router and an Internal Route Processor
In this lab exercise, you configure routing between an internal route processor and an
external router.

Configuring the Router for the Native VLAN


A native VLAN is configured on the trunk link, as shown in Figure 4-17. An 802.1Q trunk
requires the native VLAN for each opposing trunk port on a trunk link to match. Both the
router and the switch require the native VLAN to be configured unless the default of VLAN 1
is desired (but this is not recommended).

Figure 4-17 The Native VLAN Must Be Configured on a Trunk Link Between a Router and a
Catalyst Switch

WAN

s 0/0

802.1Q Trunk

fa 0/1 fa 0/0

Layer 2 External
Switch Router
1439_CCNP_3.book Page 278 Wednesday, October 27, 2004 9:54 AM

278 Chapter 4: Inter-VLAN Routing

With Cisco IOS software Release 12.1(3)T and later, the router’s subinterface can be config-
ured as the native VLAN, as shown in Example 4-6.

Example 4-6 The Native VLAN Is Configured on a Trunk Link Between a Layer 2 Switch and an External Router
Using a Subinterface on the Router for the Native VLAN

! Layer 2 Switch Commands:


Switch(config)#interface vlan 10
Switch(config-if)#description Management VLAN 10
Switch(config-if)#ip address 192.168.10.2 255.255.255.0
Switch(config-if)#no shutdown
Switch(config)#interface fa 0/1
Switch(config-if)#switchport mode trunk
Switch(config-if)#switchport trunk native vlan 1

! Router Commands:
Router(config)#interface fa 0/0.1
Router(config-subif)#description Control Traffic VLAN 1
Router(config-subif)#encapsulation dot1q 1 native
Router(config-subif)#ip address 192.168.1.1 255.255.255.0
Router(config)#interface fa 0/0.10
Router(config-subif)#description Management VLAN 10
Router(config-subif)#encapsulation dot1q 10
Router(config-subif)#ip address 192.168.10.1 255.255.255.0
Router(config)#interface fa 0/0.20
Router(config-subif)#description Engineering VLAN 20
Router(config-subif)#encapsulation dot1q 20
Router(config-subif)#ip address 192.168.20.1 255.255.255.0
Router(config)#interface fa 0/0.30
Router(config-subif)#description Marketing VLAN 30
Router(config-subif)#encapsulation dot1q 30
Router(config-subif)#ip address 192.168.30.1 255.255.255.0

The native option tells the router to accept any frames coming in untagged on FastEthernet0/0
as belonging to VLAN 1.
Before Cisco IOS software Release 12.1(3)T, the native VLAN had to be configured on the
router’s physical interface, as shown in Example 4-7.
1439_CCNP_3.book Page 279 Wednesday, October 27, 2004 9:54 AM

Configuring Inter-VLAN Routing 279

Example 4-7 The Native VLAN Is Configured on a Trunk Link Between a Layer 2 Switch and an External Router
Using the Physical Interface on the Router for the Native VLAN

Router(config)#interface fa 0/0
Router(config-if)#description VLAN 1
Router(config-if)#ip address 192.168.1.1 255.255.255.0
Router(config)#interface fa 0/0.10
Router(config-subif)#description Management VLAN 10
Router(config-subif)#encapsulation dot1q 10
Router(config-subif)#ip address 192.168.10.1 255.255.255.0
Router(config)#interface fa 0/0.20
Router(config-subif)#description Engineering VLAN 20
Router(config-subif)#encapsulation dot1q 20
Router(config-subif)#ip address 192.168.20.1 255.255.255.0
Router(config)#interface fa 0/0.30
Router(config-subif)#description Marketing VLAN 30
Router(config-subif)#encapsulation dot1q 30
Router(config-subif)#ip address 192.168.30.1 255.255.255.0

Configuring Router-on-a-Stick
When using an external router, you can logically divide an interface into multiple virtual sub-
interfaces. Subinterfaces provide a flexible solution for routing multiple VLANs through a
single physical interface, as illustrated in Figure 4-18.

Figure 4-18 Router-on-a-Stick Is Configured on a Trunk Link Between a Router and a Layer 2 Switch

VLAN 20
VLAN 10 192.168.2.0
192.168.1.0

Trunk VLAN 30
192.168.3.0

Physical Interface
FastEthernet 0/0
Logical Interface
FastEthernet 0/0.10
IP Address 192.168.1.1
Logical Interface
FastEthernet 0/0.20
IP Address 192.168.2.1

Logical Interface
FastEthernet 0/0.30
IP Address 192.168.3.1
1439_CCNP_3.book Page 280 Wednesday, October 27, 2004 9:54 AM

280 Chapter 4: Inter-VLAN Routing

To configure subinterfaces on a physical interface, follow these steps:


Step 1 Identify the interface.
Step 2 Define the VLAN encapsulation.
Step 3 Assign an IP address to the interface.
To identify the interface, enter the global configuration command interface FastEthernet
slot-number/port-number.subinterface-number, where slot-number/port-number.subinterface-
number is the physical and logical interface.
To define the VLAN encapsulation, enter the subinterface configuration command encapsu-
lation dot1Q vlan-number, where vlan-number is the VLAN for which the subinterface
carries traffic.
To assign the IP address to the subinterface, enter the interface configuration command ip
address ip-address subnet-mask, where ip-address and subnet-mask are the 32-bit network
address and mask of the specific interface.
In Figure 4-18, the router has three subinterfaces configured on FastEthernet interface 0/0.
These three interfaces are identified as FastEthernet0/0.10, FastEthernet0/0.20, and
FastEthernet0/0.30. All interfaces are encapsulated for 802.1Q. Interface FastEthernet0/0.10
is routing packets for VLAN 10, whereas interface FastEthernet0/0.20 is routing packets for
VLAN 20 and FastEthernet0/0.30 is routing packets for VLAN 30.
Note that the subinterface number does not have to match the VLAN number, but that is com-
mon practice.
With Cisco IOS software Release 12.1(3)T and later, the router subinterface can be config-
ured as the native VLAN. The native option tells the router to accept any frames coming in
untagged on FastEthernet0/0 as belonging to VLAN 1. Example 4-8 shows the configuration
with Cisco IOS software Release 12.1(3)T and later.

Example 4-8 With IOS 12.1(3)T and Later, One of the Router Subinterfaces Is Configured as the
Native VLAN

! Layer 2 Switch Commands:


Switch(config)#interface vlan 10
Switch(config-if)#description Management VLAN 10
Switch(config-if)#ip address 192.168.10.2 255.255.255.0
Switch(config-if)#no shutdown

Switch(config)#interface fa0/0.1
Switch(config-if)#switchport mode trunk
Switch(config-if)#switchport trunk native vlan 1
1439_CCNP_3.book Page 281 Wednesday, October 27, 2004 9:54 AM

Configuring Inter-VLAN Routing 281

Example 4-8 With IOS 12.1(3)T and Later, One of the Router Subinterfaces Is Configured as the
Native VLAN (Continued)

! Router Commands:
Router(config)#interface fa0/1.1
Router(config-subif)#description Control Traffic VLAN 1
Router(config-subif)#encapsulation dot1q 1 native
Router(config-subif)#ip address 192.168.1.1 255.255.255.0

Router(config)#interface fa0/0.10
Router(config-subif)#description Management VLAN 10
Router(config-subif)#encapsulation dot1q 10
Router(config-subif)#ip address 192.168.10.1 255.255.255.0

Router(config)#interface fa0/0.20
Router(config-subif)#description Engineering VLAN 20
Router(config-subif)#encapsulation dot1q 20
Router(config-subif)#ip address 192.168.20.1 255.255.255.0

Router(config)#interface fa0/0.30
Router(config-subif)#description Marketing VLAN 30
Router(config-subif)#encapsulation do1q 30
Router(config-subif)#ip address 192.168.30.1 255.255.255.0

Before Cisco IOS software Release 12.1(3)T, the native VLAN had to be configured on the
router’s physical interface, as shown in Example 4-9.

Example 4-9 Before IOS 12.1(3)T, the Physical Interface Was Configured with the Native VLAN

! Layer 2 Switch Commands:


Switch(config)#interface vlan 10
Switch(config-if)#description Management VLAN 10
Switch(config-if)#ip address 192.168.10.2 255.255.255.0
Switch(config-if)#no shutdown

Switch(config)#interface fa0/0.1
Switch(config-if)#switchport mode trunk
Switch(config-if)#switchport trunk native vlan 1
continues
1439_CCNP_3.book Page 282 Wednesday, October 27, 2004 9:54 AM

282 Chapter 4: Inter-VLAN Routing

Example 4-9 Before IOS 12.1(3)T, the Physical Interface Was Configured with the Native VLAN (Continued)

! Router Commands:
Router(config)#interface fa0/0
Router(config-if)#description VLAN 1
Router(config-if)#ip address 192.168.1.1 255.255.255.0

Router(config)#interface fa0/0.10
Router(config-subif)#description Management VLAN 10
Router(config-subif)#encapsulation dot1q 10
Router(config-subif)#ip address 192.168.10.1 255.255.255.0

Router(config)#interface fa0/0.20
Router(config-subif)#description Engineering VLAN 20
Router(config-subif)#encapsulation dot1q 20
Router(config-subif)#ip address 192.168.20.1 255.255.255.0

Router(config)#interface fa0/0.30
Router(config-subif)#description Marketing VLAN 30
Router(config-subif)#encapsulation do1q 30
Router(config-subif)#ip address 192.168.30.1

Lab 4.3.1 Inter-VLAN Routing with an External Router


In this lab exercise, you configure an external router (router-on-a-stick) to route inter-
VLAN traffic.

Verifying the Inter-VLAN Routing Configuration


To verify that inter-VLAN routing functionality is available, use the show ip route command.
A useful summary of interfaces, both virtual and routed, can be obtained through the use of
the command show ip interface brief, as shown in Example 4-10 for the topology shown in
Figure 4-19.

Example 4-10 The show ip interface brief Command Is Useful for Verifying a Router-on-a-Stick/Inter-VLAN
Routing Configuration

Interface IP-Address OK? Method Status Protocol


Vlan1 unassigned YES unset administratively down down
Vlan10 10.0.10.1 YES manual up up
1439_CCNP_3.book Page 283 Wednesday, October 27, 2004 9:54 AM

Configuring Inter-VLAN Routing 283

Example 4-10 The show ip interface brief Command Is Useful for Verifying a Router-on-a-Stick/Inter-VLAN
Routing Configuration (Continued)

Vlan20 10.0.20.1 YES manual up up


FastEthernet0/1 10.0.1.1 YES manual up up
FastEthernet0/2 unassigned YES unset down down
FastEthernet0/3 unassigned YES unset up up
FastEthernet0/4 unassigned YES unset up up
FastEthernet0/5 unassigned YES unset up up
FastEthernet0/6 unassigned YES unset up up
FastEthernet0/7 unassigned YES unset up up
FastEthernet0/8 unassigned YES unset up up
FastEthernet0/9 unassigned YES unset up up
FastEthernet0/10 unassigned YES unset down down
FastEthernet0/11 unassigned YES unset down down
FastEthernet0/12 unassigned YES unset down down

Figure 4-19 The Layer 3 Switch Is Set Up with Two User VLANs

WAN

s 0/0

Routed Port
fa 0/1 fa 0/0

External
10.0.20.0/24
VLAN 20 Router
10.0.10.0/24
VLAN 10

The command show ip route confirms that IP routing is enabled on a Layer 3-capable switch,
as shown in Example 4-11.
1439_CCNP_3.book Page 284 Wednesday, October 27, 2004 9:54 AM

284 Chapter 4: Inter-VLAN Routing

Example 4-11 The show ip route Command Is Used on a Layer 3 Switch Just as It Is on a Router

Switch#show ip route
Codes:C - connected, S - static, I - IGRP, R - RIP, M - mobile, B - BGP
D - EIGRP, EX - EIGRP external, IA - OSPF, IA - OSPF inter area
N1 - OSPF NSSA external type1, N - OSPF NSSA external type 2
E1 - OSPF external type1, E2 - OSPF external type2, E - EGP
i - IS-IS, L1 - IS-IS level-1, L2 - IS-IS level-2, ia - IS-IS inter area
* -candidate default, U - per-user static route, o - ODR
P - periodic downloaded static route

Gateway of last resort is not set

10.0.0.0/24 is subnetted, 3 subnets

C 10.0.10.0 is directly connected, Vlan10


C 10.0.1.0 is directly connected, FastEthernet0/1
C 10.0.20.0 is directly connected, Vlan20

The presence of the directly connected networks in the routing table indicates that IP routing
is enabled. Without IP routing enabled, the command show ip route produces an empty out-
put, as shown in Example 4-12.

Example 4-12 The show ip route Command Yields Empty Output When IP Routing Is Disabled

Switch#show ip route
Default gateway is not set
Host Gateway Last Use Total Uses Interface

ICMP redirect cache is empty


Switch#

To determine whether a switch port is acting as a Layer 2 member of a VLAN or is config-


ured as a routed port, use either the show ip interface fastethernet module/port command or
the show interface fastethernet module/port switchport command. In Example 4-13, these
two commands have been applied to interface FastEthernet0/1. This interface has been con-
figured as a routed port through the use of the interface command no switchport. The output
illustrates that the interface has an IP status but no switchport status. This indicates that it is
configured for routing.
1439_CCNP_3.book Page 285 Wednesday, October 27, 2004 9:54 AM

Configuring Inter-VLAN Routing 285

Example 4-13 Two Useful Commands for Verifying Whether a Switch Port Is Configured as a Routed Port

Switch#show ip interface fastethernet 0/1

FastEthernet0/1 is up, line protocol is up


Internet address is 10.0.1.1/24
Broadcast address is 255.255.255.255
Address determined by setup command
MTU is 1500 bytes
Helper address is not set
Directed broadcast forwarding is disabled
Outgoing access list is not set Inbound access list is not set
Proxy ARP is enabled
Local Proxy ARP is disabled
Security level is default
Split horizon is enabled
ICMP redirects are always sent
IP CEF Fast switching turbo vector
IP multicast fast switching is enabled
IP multicast distributed fast switching is disabled
IP route-casch flags are Fast, CDF
Router Discovery is disabled
IP output packet accounting is disabled
IP access violation accounting is disabled
TCP/IP header compression is disabled
RTP/IP header compression is disabled
Probe proxy name replies are disabled
Policy routing is disabled
Network address translation is enabled, interface in domain outside
WCCP Redirect outbound is disabled
WCCP Redirect inboud is disabled
WCCP Redirect exclude is disabled
BGP Policy Mapping is disabled
Switch#
Switch#show interface fastethernet 0/1 switchport
Name: Fa0/1
Switchport: Disabled
1439_CCNP_3.book Page 286 Wednesday, October 27, 2004 9:54 AM

286 Chapter 4: Inter-VLAN Routing

When the same commands are applied to interface FastEthernet0/2, which is configured as a
regular switchport and VLAN member, the output, shown in Example 4-14, clearly shows
that the interface has no Layer 3 functionality but is acting as a Layer 2 interface.

Example 4-14 The show ip interface fastethernet and show interface fastethernet switchport Commands
Clarify Whether a Port Is Configured as a Layer 2 Switch Port

Switch#show ip interface fastethernet

FastEthernet0/2 is down, line protocol is down


Inbound access list is not set
Switch#

Switch#show interface fastethernet 0/2 switchport


Name: Fastethernet0/2
Switchport: Enabled
Administrative Mode: dynamic desirable
Operational Mode: down
Administrative Trunking Encapsulation: negotiate
Negotiation of Trunking: On
Access Mode VLAN: 1 (default)
Trunking Native Mode VLAN: 1 (default)
Administrative private-vlan host-association: none
Administrative private-vlan mapping: none
Operational private-vlan: none
Trunking VLANs Enabled: ALL
Pruning VLANs Enabled: 2-1001
Protected: false
Unknown unicast blocked: disabled
Unknown multicast blocked: disabled
Voice VLAN: none (Inactive)
Appliance trust: none

Troubleshooting Inter-VLAN Routing


The first step in troubleshooting inter-VLAN routing is to ensure that routing is actually
enabled using the show ip route command. If the routing table displays no entries, you need
to enable IP routing with the ip routing global configuration command.
1439_CCNP_3.book Page 287 Wednesday, October 27, 2004 9:54 AM

Summary 287

After verifying routing, ensure that the Layer 2 VLANs and Layer 3 IP addressing are as
intended using the show ip interfaces brief command. This command also reveals whether
routing is configured for an individual switch interface or an entire VLAN. If communication
with a switch seems to be a problem, check that the switch’s IP address is in the appropriate
VLAN and that the gateway is set.
Assuming that the VLANs are appropriately addressed, it is useful to ensure that no Layer 2
problems exist by pinging within each VLAN and verifying that it is possible to reach the
router interface with every VLAN.
If communications within the VLAN are correct, but communications between the VLANs
are not working, check the Layer 3 configuration. Be sure that the appropriate gateway is set
on hosts and switch management interfaces. Also verify the IP network address and subnet
mask.
Any remaining routing issues are likely to be the result of incorrectly configured routing
protocols or the somewhat-tricky native VLAN issue. In particular, take care to prescribe
the native VLAN for a trunk link. No specific debug or troubleshooting commands help you
identify problems with the native VLAN. Some Catalyst platforms, such as the Catalyst 6000,
report an error when a port receives a tagged frame for a VLAN it was expecting to be untagged,
but not all models behave this way. The best strategy for dealing with native VLAN trunking
problems is to maintain an awareness of the issue and to take care with the configuration.

Summary
Inter-VLAN routing is an essential component of designing a scalable switched LAN. This
chapter examined the three methods of routing between VLANs and provided guidelines for
choosing between the alternatives.
This chapter also demonstrated how to configure VLAN routing on both switch virtual inter-
faces and routed ports. It concluded with coverage of the commands needed to verify and
troubleshoot inter-VLAN routing.
1439_CCNP_3.book Page 288 Wednesday, October 27, 2004 9:54 AM

288 Chapter 4: Inter-VLAN Routing

Key Terms
default VLAN Upon initial switch configuration, all switch ports can be configured to be
members of a particular VLAN other than VLAN 1. This particular VLAN is the default
VLAN. When a user plugs a device into the switch, it automatically is associated with the
default VLAN. If, upon initial switch configuration, not all switch ports are configured to
be members of a VLAN other than VLAN 1, VLAN 1 is the default VLAN.
management VLAN Most of today’s switches and routers can be accessed remotely via
Telnet or SSH to the device’s management IP address. The recommended practice is to put
these and other networking devices in their own VLAN, known as the management VLAN.
The management VLAN should be a separate VLAN, independent of any user VLANs, the
native VLAN, and VLAN 1.
Multilayer Switch Feature Card (MSFC) MSFC1 and MSFC2 are daughter cards to the
Catalyst 6000 Supervisor Engine. They provide multilayer switching functionality and rout-
ing services between VLANs.
Multilayer Switch Module (MSM) A line card for Catalyst 6000 family switches that runs
the Cisco IOS router software and directly interfaces with the Catalyst 6000 backplane to
provide Layer 3 switching.
native VLAN The IEEE committee that defined 802.1Q decided that, for backward compat-
ibility, it was desirable to associate all untagged traffic on an 802.1Q link with a specific
VLAN—the native VLAN. This VLAN is implicitly used for all the untagged traffic received
on an 802.1Q-capable port.
Policy Feature Card (PFC) Performs hardware-based Layer 2 to Layer 4 packet forward-
ing as well as packet classification, traffic management, and policy enforcement.
route processor The main system processor in a Layer 3 networking device, responsible for
managing tables and caches and for sending and receiving routing protocol updates.
Route Switch Feature Card (RSFC) A daughter card to the Catalyst 5000/5500 Supervisor
Engine IIG and IIIG that provides inter-VLAN routing and multilayer switching functional-
ity. The RSFC runs Cisco IOS router software and directly interfaces with the Catalyst switch
backplane.
Route Switch Module (RSM) A line card that interfaces with the Supervisor Engine of a
Catalyst 5000/5500 switch to provide inter-VLAN routing functionality. The RSM runs the
Cisco IOS.
router-on-a-stick A method of inter-VLAN routing consisting of an external router with a
Fast Ethernet, Gigabit Ethernet, or EtherChannel trunk connecting to a switch, using ISL or
802.1Q. Subinterfaces on the trunk are created to correspond with VLANs in a one-to-one
fashion.
1439_CCNP_3.book Page 289 Wednesday, October 27, 2004 9:54 AM

Check Your Understanding 289

user VLAN A VLAN created to segment a group of users, either geographically or logically,
from the rest of the network. User VLAN traffic is typically configured to be independent of
VLAN 1, the native VLAN, and the management VLAN.

Check Your Understanding


Use the following review questions to test your understanding of the concepts covered in this
chapter. Answers are listed in Appendix A, “Check Your Understanding Answer Key.”
1. Which of the following are options that are available for inter-VLAN routing?

A. Adding a route processor to a chassis-based switch with a daughter card or module

B. Router-on-a-stick

C. One router-to-switch link per VLAN

D. Fixed chassis (nonmodular) multilayer switch


2. What is required in a Layer 2 core with physical loops?

A. Routing protocol

B. HSRP

C. STP

D. VTP
3. What is the most scalable inter-VLAN routing option?

A. Layer 2 switch

B. Layer 3 switch

C. Router

D. Router-on-a-stick
4. Which of the following are examples of modules or daughter cards that provide routing
functionality in a chassis-based Catalyst switch?
A. Multilayer Switch Module

B. Route Switch Feature Card

C. Route Switch Module

D. Multilayer Switch Feature Card


1439_CCNP_3.book Page 290 Wednesday, October 27, 2004 9:54 AM

290 Chapter 4: Inter-VLAN Routing

5. Which of the following modules have embedded route processors?

A. Catalyst 6500 Supervisor Engine 720

B. Catalyst 4006 Supervisor Engine II

C. Catalyst 4500 Supervisor Engine III

D. Catalyst 4500 Supervisor Engine IV


6. Which of the following are required for performing router-on-a-stick?

A. Router

B. IEEE 802.1Q or ISL

C. Routing protocol

D. Layer 2 switch port


7. A switch virtual interface is configured with what command(s)?

A. Switch#vlan database

B. Switch(vlan)#vlan

C. Switch(config)#interface vlan

D. Switch(config)#vlan
8. What command is required to configure a switch port on a multilayer Catalyst switch as
a routed port?
A. ip routing

B. no shutdown

C. interface vlan

D. no switchport
9. Before Cisco IOS software Release 12.1(3)T, the native VLAN was configured on
which interface on a router?
A. Physical interface

B. Subinterface

C. Switch virtual interface

D. Bridge virtual interface


1439_CCNP_3.book Page 291 Wednesday, October 27, 2004 9:54 AM

Check Your Understanding 291

10. What Catalyst 3550 commands can be used to determine whether a port is a routed port
or a Layer 2 switch port?
A. show port routed

B. show ip interface switchport

C. show vlan

D. show ip interface brief


1439_CCNP_3.book Page 292 Monday, November 1, 2004 11:16 AM

Objectives
After completing this chapter, you will be able to perform tasks related to the following:
■ List and understand the role of Multilayer Switching (MLS) components.
■ Have a general understanding of the hardware platforms and Cisco IOS software
Releases required for MLS and Cisco Express Forwarding (CEF).
■ Explain MLS operation.
■ Understand the advantages of CEF over MLS.
■ Configure MLS and CEF.
■ Verify MLS and CEF operation.
1439_CCNP_3.book Page 293 Wednesday, October 27, 2004 9:54 AM

Chapter 5

Multilayer Switching
The desire for high-speed networking motivates the development of new technologies. One of
the bottlenecks in high-speed networking is the decision-making process within the router. Until
recently, routers forwarded traffic without the aid of specialized hardware designed to rewrite
Protocol Data Unit (PDU) headers to speed up the process. In recent years, technologies and
accompanying hardware have enhanced the process of rewriting PDU headers to move traffic
to its ultimate destination.
A number of software and hardware combinations enable hardware-based PDU header rewrites
and forwarding. Two of the methods used by Cisco devices are Multilayer Switching (MLS) and
Cisco Express Forwarding (CEF). The hardware requirements for each of these technologies
are strict, so it is important to do some research before making a purchase. This chapter clarifies
the hardware and software requirements for supporting MLS and CEF.
MLS is a technology used by a small number of older Catalyst switches to provide wire-speed
routing. MLS is sometimes called “route once, switch many,” where the first packet of a flow is
routed by the router in software, and the remaining packets are forwarded in hardware by the
switch.
CEF is the technology used by newer Cisco devices to provide wire-speed routing. MLS looks at
the first packet in a flow and caches the requisite information to permit subsequent packets to be
switched independent of the route processor. CEF lets packet switching circumvent the route
processor altogether. This is accomplished by using specialized data structures that are dynami-
cally updated by a communication process between the route processor and the switch processor.
Therefore, the traditional routing of the first packet required by MLS is avoided. In general, CEF
can be thought of as “route never, switch always,” where the packet is never routed by the router
in software and is always forwarded in hardware by the switch.
1439_CCNP_3.book Page 294 Wednesday, October 27, 2004 9:54 AM

294 Chapter 5: Multilayer Switching

This chapter shows how MLS and CEF work and how to configure these technologies. This
chapter also covers verifying and troubleshooting MLS and CEF and interpreting the output
of various show commands relating to MLS and CEF.

Multilayer Switching
The term multilayer switching is used for two distinct things. On one hand, it is a general net-
work design term that refers to hardware-based PDU header rewriting and forwarding, based
on information specific to one or more Open System Interconnection (OSI) layers.
On the other hand, as characterized in this chapter, MLS refers to a specific technology employed
by various Cisco devices to perform wire-speed PDU header rewrites and forwarding. To help
differentiate between the two uses of the term multilayer switching, when the acronym MLS
is used (as opposed to the expanded term), it refers to the Cisco-specific technology.
MLS was the first technological step in solving the router-as-a-bottleneck issue. MLS is also
responsible for blurring the lines with respect to using the OSI model as a means of delineat-
ing per-OSI layer functions. With MLS, Layer 3 switching speeds approximate those of
Layer 2 switching. This has a dramatic impact on network design. The trend is to incorporate
more and more Layer 3 functionality into what are traditionally Layer 2 devices. For example,
the Catalyst 3550 access layer switch uses CEF by default, making it a true multilayer switch.
The discussion of MLS in the following sections begins by detailing the hardware and soft-
ware requirements, followed by an explanation of MLS components and operations.

MLS Hardware and Software Requirements


The requirements for running MLS in the network are specific. Many technologies are widely
available on Cisco products. For example, most Cisco router platforms have Cisco IOS soft-
ware releases that support Internetwork Packet Exchange (IPX). However, with MLS, wide-
spread support is not the case, and options are limited.
The following sections examine the multilayer switching hardware and software requirements
for switch and router platforms running MLS and CEF.

MLS
Catalyst 5000 series switches comprise the majority of MLS deployments. For Catalyst 5000
switches, the MLS requirements are as follows:
■ Supervisor Engine III with NetFlow Feature Card (NFFC) or NFFC II, a Supervisor
Engine IIG, or a Supervisor Engine IIIG (the IIG and IIIG have integrated NFFCs). The
only NFFCs still available for purchase are the NFFC-A and NFFC II-A. The other
NFFCs were last sold on April 30, 2000.
1439_CCNP_3.book Page 295 Wednesday, October 27, 2004 9:54 AM

Multilayer Switching 295

■ Catalyst 5000 Route Switch Module (RSM), Catalyst 5000 Route Switch Feature Card
(RSFC), Catalyst 6000 Multilayer Switch Feature Card (MSFC), or Catalyst 6000
Multilayer Switch Module (MSM).
■ CatOS 4.1(1) or later.
■ Cisco IOS software Release 12.0(3c)W5(8a) or later on the RSFC.
■ Cisco IOS software Release 11.3(2)WA4(4) or later on the RSM.
Catalyst 2926G switches can also work in tandem with external Cisco routers to support
MLS. Catalyst 2926G switches are fixed-configuration switches. They were last sold in May
2000 and have been replaced by the 2948G switches.
The hardware and software guidelines for external routers are as follows:
■ Cisco 3600, 4500, 4700, 7200, or 7500 router or Catalyst 8500 switch router externally
attached to the Catalyst 5000 series switch.
■ The connection between the external router and the Catalyst 5000 series switch must be
a Fast Ethernet or Gigabit Ethernet link, an Inter-Switch Link (ISL) or IEEE 802.1Q
trunk, or a Fast or Gigabit EtherChannel.
■ Cisco IOS software Release 11.3(2)WA4(4) or later on Cisco 4500, 4700, 7200, or
7500 routers. Cisco IOS software Release 12.0 is the earliest release available on 8500
series switch routers.
■ Cisco IOS software Release 12.0(2) or later on Cisco 3600 series routers.
■ Catalyst 6000 MSFC on a Supervisor Engine with CatOS 6.3.
■ Catalyst 6000 MSM.
For Catalyst 6000 switches, the MLS hardware and software guidelines are as follows:
■ Catalyst 6000 family switches do not support an external Multilayer Switching Route
Processor (MLS-RP). The MLS-RP must be a MSM or MSFC. As of July 6, 2000, the
MSM is no longer available for purchase and has been replaced by the MSFC.
■ MSFC, Policy Feature Card (PFC), and CatOS 5.1CSX or later.
■ MSM, CatOS 5.2(1)CSX or later, and Cisco MSM IOS software Release 12.0(1a)WX5(6d)
or later.

CEF
Multilayer switching in the general sense is implemented with CEF in newer Catalyst 6500
products. In particular, Supervisor Engine II with Policy Feature Card 2 (PFC2), Multilayer
Switch Feature Card 2 (MSFC2), and Supervisor Engine 720, comprise two standard config-
urations for newly purchased Catalyst 6500 switches. This configuration relies natively on CEF.
1439_CCNP_3.book Page 296 Wednesday, October 27, 2004 9:54 AM

296 Chapter 5: Multilayer Switching

The Catalyst 4006 switch with the Layer 3 Services Module and the Catalyst 4500 switch
with the Supervisor Engine III or Supervisor Engine IV also natively support CEF.
The Catalyst 3550 switch with the Enhanced Multilayer Software Image also relies on a
CEF-based routing architecture to deliver high-performance dynamic IP routing. Note that
the 3550 does not support IPX or AppleTalk.
With the hardware and software requirements clarified, it’s important to understand how
MLS works. The following sections detail the concepts of MLS flow, MLS Switching Engine
(MLS-SE), and MLS Route Processor (MLS-RP).

MLS Components
The idea of MLS is simple. MLS looks at the first packet in a flow of data and caches some
header information describing the flow. Subsequent packets in the flow circumvent the router,
because the switch has cached the data necessary to rewrite the packet header, which it does.
This is known as wire-speed routing.
MLS switches unicast IP data packet flows between IP subnets using advanced ASIC switch-
ing hardware, offloading processor-intensive packet routing from network routers. The packet
forwarding function is moved to Layer 3 switches whenever a partial or complete switched
path exists between two hosts. Packets that do not have a partial or complete switched path to
reach their destinations are still forwarded in software by routers. Standard routing protocols,
such as Open Shortest Path First (OSPF), Enhanced Interior Gateway Routing Protocol (EIGRP),
Routing Information Protocol (RIP), and Intermediate System-to-Intermediate System (IS-IS),
are used for route determination.
IP is a connectionless protocol, and every packet is delivered independent of every other
packet. However, actual network traffic consists of many end-to-end conversations, or flows,
between users or applications.
A flow is a unidirectional sequence of packets between a particular source and destination
that share the same Layer 3 and Layer 4 information. For example, Telnet traffic transferred
from a particular source to a particular destination is a flow separate from File Transfer Protocol
(FTP) packets between the same source and destination. Communication from a client to a
server, and from the server to the client, comprises separate and distinct flows.
If a flow is defined administratively by destination IP address alone, traffic from multiple
users or applications to that destination is included in that flow.
The MLS Switching Engine (MLS-SE) is the set of hardware components on a Catalyst switch,
excluding the route processor, necessary to support MLS. For example, a Catalyst 5000 with
a Supervisor Engine IIIG is an MLS-SE. The MLS Route Processor (MLS-RP) is a Cisco
device with a route processor that supports MLS. For example, a Cisco 3620 router is an
MLS-RP. Only certain combinations of MLS-SEs and MLS-RPs can run MLS.
1439_CCNP_3.book Page 297 Wednesday, October 27, 2004 9:54 AM

Multilayer Switching 297

MLS Flows
An MLS-SE maintains a Layer 3 switching table (the Layer 3 MLS cache) for Layer 3 switched
flows. After the MLS cache is created, packets identified as belonging to an existing flow can
be switched based on the cached information. The MLS cache maintains flow information for
all active flows. The maximum size of the MLS cache is 128,000 entries. The larger the active
cache, the greater the likelihood that a flow will not be switched by the MLS-SE and will get
forwarded to the router.
An MLS cache entry is created for the initial packet of each flow. Upon receipt of a packet
that does not match any flow currently in the MLS cache, a new IP multilayer switching (IP
MLS) entry is created. This first packet has special significance; it is detailed more in the next
section.
A flow’s state and identity are maintained while packet traffic is active. When traffic for a
flow ceases, the entry ages out. The aging time for MLS entries kept in the MLS cache can be
configured. If an entry is not used for the specified period of time, it ages out.
The MLS-SE uses flow masks to determine how MLS entries are created. The flow mask is a
set of criteria, based on a combination of source IP address, destination IP address, protocol,
and protocol ports, that describes the flow’s characteristics. The MLS-SE learns the flow
mask through Multilayer Switching Protocol (MLSP) messages from each MLS-RP for
which the MLS-SE is performing Layer 3 switching. MLSP is the protocol used to communi-
cate MLS information between the MLS-SE and MLS-RP. In particular, the MLS-SE popu-
lates its Layer 2 Content-Addressable Memory (CAM) table with updates received from
MLSP packets. When the MLS-SE flow mask changes, the entire MLS cache is purged.
The three flow masks are as follows:
■ destination-ip—The least-specific flow mask. The MLS-SE maintains one MLS entry
for each destination IP address. All flows to a given destination IP address use this MLS
entry. This mode is used if no access control lists (ACLs) are configured on any of the
MLS-RP interfaces.
■ source-destination-ip—The MLS-SE maintains one MLS entry for each source and
destination IP address pair. All flows between a given source and destination use this
MLS entry, regardless of the IP protocol ports. This mode is used if any of the MLS-RP
interfaces has a standard access control list (ACL).
■ ip-flow—The most-specific flow mask. The MLS-SE creates and maintains a separate
MLS cache entry for every IP flow. An ip-flow entry includes the source IP address,
destination IP address, protocol, and protocol ports. This mode is used if any of the
MLS-RP interfaces has an extended ACL.
1439_CCNP_3.book Page 298 Wednesday, October 27, 2004 9:54 AM

298 Chapter 5: Multilayer Switching

When a packet is Layer 3 switched from a source host to a destination host, the MLS-SE
performs a packet rewrite based on information learned from the MLS-RP and stored in the
MLS cache.
If Host A and Host B are on different VLANs, and Host A sends a packet to the MLS-RP to
be routed to Host B, the MLS-SE recognizes that the packet was sent to the MAC address of
the MLS-RP. The MLS-SE checks the MLS cache and finds the entry matching the flow in
question.
When the MLS-SE receives the packet, it is formatted as shown in Figure 5-1.

Figure 5-1 The MLS-SE First Receives a Frame in a Flow with the Destination MAC Address of
the MLS-RP

Frame Header IP Header Payload


Destination Source Destination Source TTL Checksum

Data Checksum

MLS-RP MAC Host A MAC Host B IP Host A IP n calculation1

The MLS-SE rewrites the Layer 2 frame header, changing the destination MAC address to
the MAC address of Host B and the source MAC address to the MAC address of the MLS-
RP. These MAC addresses are stored in the MLS cache entry for this flow. The Layer 3 IP
addresses remain the same, but the IP header Time-to-Live (TTL) is decremented, and the
IP checksum is recomputed. The MLS-SE rewrites the switched Layer 3 packets so that they
appear to have been routed by a router. The MLS-SE forwards the rewritten packet to the
virtual LAN (VLAN) of Host B, the destination VLAN is stored in the MLS cache entry, and
Host B receives the packet.
After the MLS-SE performs the packet rewrite, the packet is formatted as shown in Figure 5-2.

Figure 5-2 After a Frame Has Passed Through the MLS-SE and to the MLS-RP, It Returns to
the MLS-SE with the Source MAC Address of the MLS-RP

Frame Header IP Header Payload


Destination Source Destination Source TTL Checksum

Data Checksum

Host B MAC MLS-RP MAC Host B IP Host A IP n+1 calculation2


1439_CCNP_3.book Page 299 Wednesday, October 27, 2004 9:54 AM

Multilayer Switching 299

Figure 5-3 shows an IP MLS network topology. In this example, Host A is on Sales VLAN 1
(IP subnet 192.168.1.0), Host B is on Marketing VLAN 3 (IP subnet 192.168.3.0), and Host
C is on Engineering VLAN 2 (IP subnet 192.168.2.0).

Figure 5-3 IP Addresses, MAC Addresses, Protocol Ports, and Destination VLANs Are Stored in
the MLS Cache

Source IP Destination Application Rewrite Source/ Destination


Address IP Address Destination VLAN
MAC Address
192.168.1.1 192.168.3.1 FTP Db:Bb Marketing
192.168.1.1 192.168.2.1 HTTP Db:Cc Engineering

192.168.2.1 192.168.1.1 HTTP Db:Aa Sales

MAC = Dd MAC = Bb
RSM
MAC = Aa Host B
eting
VLA N 3/Mark
VLAN 1/Sales
Host A
VLA 192.168.3.1
N 2/M
192.168.1.1 arke
ting
MAC = Cc

Host C
Data 171.59.1.2:2000 Aa:Dd

192.168.2.1

Data 171.59.1.2:2000 Dd:Cc

When Host A initiates an FTP file transfer to Host B, an MLS entry for this flow is created as
shown. The MLS-SE stores the MAC addresses of the MLS-RP and Host B in the MLS entry
when the MLS-RP forwards the first packet from Host A through the switch to Host B. The
MLS-SE uses this information to rewrite subsequent packets from Host A to Host B.
Similarly, a separate MLS entry is created in the MLS cache for the HTTP traffic from Host A
to Host C and for the HTTP traffic from Host C to Host A. The destination VLAN is stored as
part of each MLS entry so that the correct VLAN identifier is used when encapsulating traffic
on trunk links.
MLS creates flows based on ACLs configured on the MLS-RP. IP MLS allows the network
administrator to enforce ACLs on every packet of the flow without compromising IP MLS
performance. When IP MLS is enabled, the MLS-SE handles standard and extended ACL
permit traffic at wire speed. Traffic that is denied by an ACL is always handled by the MLS-RP,
not the MLS-SE. Route topology changes and the addition or modification of ACLs are
reflected in the IP MLS switching path automatically on the MLS-SE.
1439_CCNP_3.book Page 300 Wednesday, October 27, 2004 9:54 AM

300 Chapter 5: Multilayer Switching

For example, when Host A wants to communicate with Host B, it sends the first packet to the
MLS-RP. If an ACL is configured on the MLS-RP to deny access from Host A to Host B, the
MLS-RP receives the packet, checks the ACL to see if the packet flow is permitted, and dis-
cards the packet based on the ACL. Because the first packet for this flow does not return from
the MLS-RP, an MLS cache entry is not established by the MLS-SE.
If a flow is already being Layer 3 switched by the MLS-SE, and the ACL is created on the
MLS-RP, the MLS-SE learns of the change through MLSP and immediately enforces secu-
rity for the affected flow by purging it from the MLS cache. New flows are created based on
the restrictions imposed by the ACL.
Similarly, when the MLS-RP detects a routing topology change, the appropriate MLS cache
entries are deleted in the MLS-SE. New flows are created based on the new topology.

MLS Operation
MLS operation consists of four distinct steps:
Step 1 MLSP multicast hello packets are sent every 15 seconds to inform the MLS-SE(s)
of the MLS-RP MAC addresses used on different VLANs and the routing and
ACL information of the MLS-RP when the router boots or after changes in
ACLs. When an MLS-SE hears the MLSP hello message indicating an IP MLS
initialization, the MLS-SE is programmed with a unique 1-byte XTAG value
for each MLS-RP and with the MLS-RP MAC addresses associated with each
VLAN. Figure 5-4 illustrates this step.

Figure 5-4 Step 1: The Exchange of Hello Packets Identifying the MLS-RP to the MLS-SE

Fast Ethernet 1/0

Hello CAM
MLSP

Packet
XTAG MAC VLAN
1 00-00-0C-11-11-11 1
1 00-00-0C-22-22-22 2

1/1
CAM
Host A Host B
2/1 3/1
1439_CCNP_3.book Page 301 Wednesday, October 27, 2004 9:54 AM

Multilayer Switching 301

Step 2 In Figure 5-5, Host A and Host B are located on different VLANs. Host A
initiates a data transfer to Host B. When Host A sends the first packet to the
MLS-RP, the MLS-SE recognizes this packet as a candidate packet for Layer 3
switching, because the MLS-SE has learned the destination MAC addresses
and VLANs of the MLS-RP through MLSP. The MLS-SE learns the Layer 3
flow information (such as the destination IP address, source IP address, and
protocol port numbers) and forwards the first packet to the MLS-RP. A partial
MLS entry for this Layer 3 flow is created in MLS cache.

Figure 5-5 Step 2: The Creation of a Partial MLS Cache Entry Based on a Candidate Packet

Fast Ethernet 1/0

Candidate
Packet

Host A Host B

The MLS-RP receives the packet, looks at its route table to determine how to
forward the packet, and applies services such as ACLs and class of service
(CoS) policy. The MLS-RP rewrites the MAC header, adding a new destination
MAC address of Host B and its own MAC address, associated with Host
VLAN, as the source.
Step 3 The MLS-RP routes the packet to the destination host. When the switch
receives the packet, the MLS-SE recognizes that the source MAC address
belongs to the MLS-RP, that the XTAG matches that of the candidate packet,
and that the packet’s flow information matches the flow for which the candi-
date entry was created. The MLS-SE considers this packet an enable packet
and completes the MLS entry in the MLS cache. Figure 5-6 illustrates this step.
1439_CCNP_3.book Page 302 Wednesday, October 27, 2004 9:54 AM

302 Chapter 5: Multilayer Switching

Figure 5-6 Step 3: Completion of the MLS Cache Entry Based on an Enable Packet

Fast Ethernet 1/0

Enable
Packet

Host A Host B

Step 4 After the MLS entry has been completed, all Layer 3 packets in the same flow
from the source host to the destination host are Layer 3/4 switched directly by
the switch, bypassing the router. IP MLS is unidirectional. A separate Layer 3
switched path is created for traffic from Host B to Host A. Figure 5-7 illustrates
this final step of MLS operation.

Figure 5-7 Step 4: The Layer 3 Switching of Subsequent Packets in the Same Flow

Fast Ethernet 1/0

Shortcut and
Rewrite Operation

NFF C
Host A Host B

Finally, some Catalyst 5000 family switching line cards have onboard hardware that performs
the rewrite (as opposed to rewrites on the Supervisor Engine), maximizing IP MLS perfor-
mance. This performance enhancement is also used on the Catalyst 2926G series switch
1439_CCNP_3.book Page 303 Wednesday, October 27, 2004 9:54 AM

Cisco Express Forwarding (CEF) 303

ports. When the line cards or individual ports perform the PDU header rewrites, this is called
inline rewrite. With inline rewrite, frames traverse the switch bus only once.
The Catalyst 5000 NFFC is a daughter card for the supervisor module that enables intelligent
network services, such as high-performance multilayer switching and accounting and traffic
management. The NFFC contains central rewrite engines (one per bus) to handle PDU
header rewrites when inline rewrite is not an option. If the central rewrite engines are used,
this means that a frame must traverse the bus twice—first with a VLAN tag for the source, on
its way to the NFFC, and second with a VLAN tag for the destination, on its way to the egress
port. To determine whether a port supports packet rewrite, use the show port capabilities
command. If the port does not support inline rewrite, the packet rewrite is done in the Super-
visor Engine.
In summary, the basic MLS ingredients are the MLS-RP, MLS-SE, and MLSP. The MLS-SE
creates flows in the MLS cache based on candidate and enable packets and ACLs configured
on the MLS-RP. The result is wire-speed routing of packets based on criteria such as destina-
tion IP address, source IP address, and protocol port numbers.

Cisco Express Forwarding (CEF)


Cisco Express Forwarding (CEF) is a multilayer switching technology that allows for increased
scalability and performance to meet the requirements of large enterprise networks. CEF has
evolved to accommodate the traffic patterns realized by modern networks. These networks
are characterized by an increasing number of short-duration flows. Shorter flows are common
in environments with a high degree of web-based activity or other highly interactive types of
traffic.
As these types of applications continue to grow in popularity, a higher-performing and more
scalable forwarding methodology is required to meet the needs of these environments. Figure 5-8
outlines the architectural model that CEF uses. The following sections compare MLS and
CEF technologies and provide a detailed description of CEF operation.

Comparing MLS and CEF


MLS is a flow-based model that entails software path handling of the first packet in a given
flow. This, in turn, creates a cache entry that can be used by subsequent packets in the flow for
accelerated performance. Although this model works extremely well, it has been shown that
in environments such as those found in the core of large enterprise networks, this model
might not always prove optimal. Specifically, a flow-based model is suboptimal when an
enterprise network has peering problems and when the number of flows is too great for the
cache size.
1439_CCNP_3.book Page 304 Wednesday, October 27, 2004 9:54 AM

304 Chapter 5: Multilayer Switching

Figure 5-8 CEF Architectural Model

Cisco 7500 Route Processor


Series Router
Running CEF Routing Forwarding
Adjacency
Information
Table Table
Base

Interface Interface Interface


Card Card Card

E1 E2 E1 E2 E1 E2

Cisco
Catalyst
Switches

Anytime a large number of routers are controlled by a large number of independent organiza-
tions, you might encounter situations in which some devices negatively affect the stability of
other devices. In this case (a peering relationship), router instability or flapping routes lead to
the purging of previously cached data. In a flow-based model, the loss of cached entries
requires that the first packet of a given flow be handled within the software path. In a peering
situation, such as that required to support the core of an enterprise network, this means that
potentially tens of thousands of flows would need to be relearned or cached by the software
path to enable further hardware acceleration. However, it is difficult to scale software-based
forwarding to simultaneously handle tens of thousands of concurrent flows per second. So
stability, and the capability to withstand route flaps, are critical. The CEF-based forwarding
model is designed to handle these situations gracefully and to minimize the impact of these
events on network stability. Another area in which a flow-based model encounters scalability
challenges is with respect to the actual number of flows that could be cached in the necessary
lookup tables. Recall that a flow entry can be expressed in one of several ways, including des-
tination-ip, source-destination-ip, and ip-flow. The greater the granularity selected, the more
specific the flow information will be but the lower the access and storage efficiency. For
example, multiple entries are likely to map to a given entry for a destination-ip flow (for
example, many clients all accessing a single server). When an ip-flow mode is selected, full
protocol and port information is stored in addition to the full source and destination IP
addresses. This, in turn, reduces the likelihood that any two entries will be capable of sharing
1439_CCNP_3.book Page 305 Wednesday, October 27, 2004 9:54 AM

Cisco Express Forwarding (CEF) 305

a given flow entry. In a large percentage of the enterprise networks in existence today, how-
ever, this is not cause for concern. The number of flows that must be supported increases as
networks grow (such as in a service provider environment), consequently leading to a situa-
tion in which the number of entries exceeds the available flow cache table space. This flow
cache table space limitation leads to suboptimal packet handling, in that packets not matched
in the flow cache must be processed in software. One option to correct the problem is to
change the flow mask to specify a less-specific mask, such as destination-ip. This solution
increases cache efficiency, but it too has its limitations, beyond which software processing
will be required.
Although the simple answer to the problem of exceeding the size of the flow cache would
appear to be increasing the number of possible entries available, in practice it is not so sim-
ple. There is a direct relationship between the speed of hardware-based forwarding and the
size of the flow cache. Simply increasing the size of the flow cache does not guarantee that
the appropriate lookup engine can parse the table sufficiently fast enough to forward flows in
hardware at high speed. It would then seem logical to increase the speed of the lookup engine
to work against the increased flow cache table. To a certain extent, this approach could be
made to work, but network administrators would have to continually upgrade equipment, an
extremely costly and inefficient solution.
A cache-based forwarding model relies on actual traffic flows to establish cache entries for
expedited forwarding. In a classical enterprise environment, this model has proven highly
effective, because traffic patterns associate a large number of sources with a much smaller
number of destinations. An example is a traditional centralized server farm, in which a large
number of clients send traffic to and receive traffic from a much smaller number of servers.
When comparing these traffic patterns to those of the Internet, it is far less likely to achieve
the many-to-one ratio typified by the enterprise data center. Because the Internet is a global
entity, it becomes increasingly difficult to maintain the flow cache and to ensure the integrity
of the data therein. This means that a certain amount of cache flux must be expected in terms
of the maintenance required to keep the state of the flow cache current. The variation in cache
state is reflected in terms of CPU utilization.
With flow-cached models, a complete forwarding table must be maintained for the proper
handling of first packets by the CPU or packets that for some other reason are incapable of
being processed in hardware. After the CPU makes a forwarding decision (part of which
involves a lookup against the routing table), an entry is made in the flow cache table, and
subsequent packets are handled in hardware.
A CEF-based mechanism experiences greatly reduced challenges presented by flow caching
models, resulting in an increase in scalability. All packets, including the first packet in a given
1439_CCNP_3.book Page 306 Wednesday, October 27, 2004 9:54 AM

306 Chapter 5: Multilayer Switching

flow, are handled in hardware. A routing table is still maintained by the router CPU, but two
additional tables are created in the CEF-based model:
■ Forwarding Information Base (FIB) table—The FIB table is a copy of the forwarding
information from the routing table. The FIB table contains the minimum information
from the routing table necessary to forward packets. The FIB table does not contain any
routing protocol information.
■ Adjacency table—The adjacency table maintains a database of node adjacencies (two
nodes are said to be adjacent if they can reach each other through a single Layer 2 hop)
and their associated Layer 2 MAC rewrite or next-hop information.
The NetFlow table is a third table. It isn’t required for CEF function, but it provides network
accounting data and is updated in parallel with the CEF-based forwarding mechanism pro-
vided by the FIB and adjacency tables.
By the router or switch performing a high-speed lookup against the FIB and adjacency tables,
a forwarding decision along with the appropriate rewrite information can be accessed in a
highly efficient and consistent manner, while also providing a mechanism offering a high
degree of scalability.

CEF Support on Cisco Devices


Although high-end Cisco routers have offered support for CEF for several years now, some
differences between the CEF implementations on Catalyst switches and Cisco routers exist.
Specifically, both implementations provide the following:
■ High-speed forwarding based on a “longest address match” lookup
■ Equal-cost path load balancing
■ Reverse Path Forwarding (RPF) checks
■ Invalidation of less-specific routes
The CEF implementation on the Catalyst 6000 family also adds the following:
■ Support for IP multicast
■ Support for IPX forwarding
■ Hardware-based forwarding of rates up to 210 Mbps in distributed CEF mode
Supported features of the CEF implementation only on the Cisco routers include the following:
■ The capability to turn off CEF-based forwarding
■ CEF per-prefix and per-prefix-length accounting
■ Accounting data from load-sharing paths
■ Per-packet load balancing
1439_CCNP_3.book Page 307 Wednesday, October 27, 2004 9:54 AM

Cisco Express Forwarding (CEF) 307

CEF is supported on the following Cisco devices:


■ Catalyst 8500 switch routers
■ Catalyst 3550 switches
■ Catalyst 2948G-L3 switches
■ Catalyst 4000 switches
■ Catalyst 6000 switches
■ Cisco routers running Cisco IOS software Release 12.2 or later
■ Some routers, such as the 7500 series, beginning with Cisco IOS software Release 12.0
The Catalyst 4000 switch supports CEF in the following combinations:
■ With the Layer 3 Services Module
■ With the Access Gateway Module
■ With Supervisor Engine III or Supervisor Engine IV
Figure 5-9 illustrates the CEF architecture for the Catalyst 4000 family Supervisor Engine III.

Figure 5-9 The Catalyst 4000 Family Supervisor Engine III and IV Provide CEF-Based
Layer 2/3/4 Switching

Packet Spanning Forward Forward


Memory Tree CAM Memory
Memory

FFE FFE Input


CAM

Multicast
Expansion
Queue Output
Table
Memory CAM

CPU
FFE = Fast Forwarding Engine

The remainder of this chapter focuses on CEF technology in the context of Catalyst 6000
family switches. In particular, the Catalyst 4000 Supervisor Engine III multilayer switching
mechanism does rely on CEF, but the architecture and Layer 2/3/4 packet flow methodology
are similar, but not identical, to that of the Catalyst 6000.
For Catalyst 6000 family switches, the CEF hardware requirements are Supervisor Engine II,
MSFC2, and PFC2, or a Catalyst 6500 series switch with Supervisor Engine 720.
1439_CCNP_3.book Page 308 Wednesday, October 27, 2004 9:54 AM

308 Chapter 5: Multilayer Switching

CEF Operation
Understanding how CEF functions on a Catalyst 6000 Supervisor Engine II requires a basic
understanding of the architecture of the Supervisor Engine II, shown in Figure 5-10.

Figure 5-10 The Catalyst 6000 Family Supervisor Engine II with the MSFC2 and PFC2 Have
CEF-Based Architectures

L2 GBIC GBIC
Fabric & Bus
PFC 2 Forwarding Interface
Table MSFC 2

Adjacency ACL Packet Pursuing IOS


FB Table Table Blue I/F & Router
Table
TCAMs L2L3 EOBC (R7000)
Multicast
Replication
NetFlow ASIC Pianancle BUS I/F
Table L2 Forwarding
L3 CEF Engine EOBC
LC-Rbus
ASIC QoS/ACL
Engine LC-Dbus
NMP
CPU
Bus Interface ASIC

Supervisor 2 Base Board Switch Fabric

The Supervisor Engine II consists of three primary components:


■ Supervisor base board—The Supervisor base board provides connectivity to the
switching fabric, 32-Gbps bus, multicast replication ASIC, Network Management
Processor (NMP), and two Gigabit Interface Converter (GBIC)-based Gigabit Ethernet
ports. In addition, the base board offers connectors for attaching the PFC2 and MSFC2
daughter boards.
■ Policy Feature Card 2 (PFC2)—PFC2 is a factory-installed daughter card of a Super-
visor Engine II. It provides an array of ASICs to enable all hardware-based forwarding.
The Layer 3 forwarding engine ASIC provides the actual CEF function via its inherent
logic. It also provides access to the various Layer 3 tables (the FIB, adjacency table,
and NetFlow table). In addition, the PFC2 daughter card also contains the ASICs that
deliver hardware-based access control lists and QoS mechanisms.
■ Multilayer Switching Feature Card 2 (MSFC2)—The MSFC2 is an optional daugh-
ter card that provides a CPU for the handling of all Layer 3 control-plane activities. The
control plane is the portion of the hardware architecture that handles route calculations.
The MSFC2 is responsible for handling any functions that cannot be handled in the
1439_CCNP_3.book Page 309 Wednesday, October 27, 2004 9:54 AM

Cisco Express Forwarding (CEF) 309

hardware elements of the PFC2, as well as the processing of all routing protocol activi-
ties, such as OSPF and Border Gateway Protocol (BGP) routing updates. The MSFC2
is also responsible for populating the IP routing table, FIB table, and adjacency table.
Of these three elements, the Supervisor base board and PFC2 are mandatory components, and
the MSFC2 element is optional (although it is effectively required for Layer 3 switching,
because it contains the CPU for the population of the CEF tables).
The CPU on the MSFC2 daughter card runs all instances of whatever configured routing pro-
tocols are required. In addition, the CPU handles packets that cannot be processed in hard-
ware. The MSFC2 is a Cisco IOS software-based router, and it is configured as such. The
configuration parameters are identical to those on a Cisco 7200 series router. With the Super-
visor Engine II, CEF is enabled by default. In fact, it cannot be disabled. For most common
CEF functions, no specific configuration is required to enable CEF beyond the standard con-
figuration of routing protocols, network interface addressing, and so on.
When the router is initialized, a routing table is constructed based on information in the
router software configuration (such as static routes, directly connected routes, and dynami-
cally learned routes via routing protocol exchanges). After the routing table is constructed,
the CPU creates the FIB and adjacency tables automatically. The FIB and adjacency tables
represent the data present within the routing table in a manner in which optimal forwarding
can be performed.
Unlike a flow cache, which is based on traffic flow, the CEF table is based on the network
topology. When a packet enters the switch, the switch Layer 3 forwarding engine ASIC per-
forms a longest-match lookup based on the destination network and the most-specific net-
mask. For example, instead of switching based on a destination address of 172.31.10.3, the
PFC2 looks for the network 172.31.10.0/24 and switches to the interface connecting to that
network. This scheme is highly efficient and does not involve the software for anything other
than the routing table and prepopulation of the FIB table. In addition, cache invalidation
because of a route flap does not occur. As soon as a change in the routing table is made, all
CEF tables are updated immediately. This makes CEF more adaptable to changes in the net-
work topology.

CEF Forwarding Information Base


The CEF FIB table consists of a four-level hierarchical tree, as shown in Figure 5-11. The
four levels are derived from the fact that IPv4 uses a 32-bit address. Each level of the hierar-
chy is based on 8 of the possible 32 bits. CEF relies on a longest-match forwarding algorithm,
meaning that the tree is searched in descending order until the “longest match,” or greatest
number of bits, is matched. The FIB tree is represented hierarchically, with the least-specific
address at the top of the tree and the most-specific address at the bottom. Each leaf is based
1439_CCNP_3.book Page 310 Wednesday, October 27, 2004 9:54 AM

310 Chapter 5: Multilayer Switching

on an 8-bit boundary, with more-specific entries in descending order. This tree (commonly
known as a 256-way radix tree) provides a highly efficient mechanism for rapid lookups,
which ensures that minimal latency is incurred during the lookup process. This tree also pro-
vides for a highly scalable architecture in that IPv4 addressing can be completely accounted
for with a minimal trade-off of performance versus table efficiency. Each leaf offers a pointer
to the appropriate next-hop entry in the adjacency table.

Figure 5-11 The CEF FIB Consists of a Four-Level Hierarchical Tree

Root
1.0.0.0

Leaf Leaf Leaf


1.1.0.0 1.2.0.0 1.3.0.0

1.1.10.0 1.3.12.0

Leaf Leaf Leaf Leaf


1.1.1.0 1.2.2.32 1.2.1.0 1.3.1.0

Leaf Leaf Leaf Leaf Leaf


1.1.1.32 1.2.2.0 1.2.1.64 1.2.1.96 1.3.1.32

1.1.1.32 1.2.1.77 1.2.1.100

The CPU of the MSFC2 builds the FIB table from the IP routing table. The appropriate IP
routing protocols first resolve the IP routing table, at which point the CEF process is invoked,
and the corresponding FIB and adjacency tables are constructed. The FIB table is maintained
separately from the routing table. The routing table contains additional information that is
important for the purposes of routing protocols but not for the actual forwarding of packets.
The FIB cannot determine which routing protocol created the route. The FIB and adjacency
tables are optimized to provide only the information that is necessary for a forwarding decision
to be made, and nothing more. It is also important to note that recursive routes are resolved
when the FIB table is built. This resolution of recursive routes has classically been a CPU-
intensive event in non-CEF implementations.
If the FIB table becomes full, subsequent entries are compared to the existing entries, and the
more-specific entries are maintained at the expense of less-specific entries. This method is
necessary to ensure that proper forwarding is maintained. For example, the less-specific route
of 1.2.0.0 is not specific enough to ensure proper routing to 1.2.1.0. To view the contents of
the FIB table, use the show ip cef detail command from the MSFC2.
1439_CCNP_3.book Page 311 Wednesday, October 27, 2004 9:54 AM

Cisco Express Forwarding (CEF) 311

CEF Adjacency Table


The adjacency table contents are fundamentally a function of the Address Resolution Protocol
(ARP) process, whereby Layer 2 addresses are mapped to corresponding Layer 3 addresses.
When the router issues an ARP request, a corresponding reply is received, and a host entry is
added to the adjacency table to reflect this. In addition, the router can glean next-hop routers
from routing updates and make entries in the adjacency table to reflect this. This transaction
lets the router build the next-hop rewrite information necessary for Layer 3 packet forward-
ing. By having this data already stored in a table, CEF can perform highly efficient and con-
sistent forwarding, because no discovery process is required. Use the show ip cef command
to view the contents of the CEF adjacency table from the MSFC2. Use the show ip cef
summary command to display a brief overview of the CEF process. The output from this
command shows information, such as the total number of adjacencies and routes.
The third table used by CEF is the NetFlow table. It isn’t discussed here, because it compiles
network accounting data and does not play a role in CEF’s PDU header rewrite mechanism.

Packet Flow for Layer 2 and Layer 3 Forwarding Decisions


This section details the data flow through the Layer 2 and Layer 3 forwarding process on
a Catalyst 6000 Supervisor Engine II. The process is fundamentally unchanged between a
Layer 2 and Layer 3 decision and is a function of whether the Layer 3 data exists. In other
words, if the MSFC2 is present, the Layer 3 path is valid. Otherwise, forwarding decisions
are made based purely on Layer 2 forwarding information. This discussion details the data
path for Layer 2 and Layer 3 lookups.
Figure 5-12 illustrates the CEF forwarding process. The following list describes each step
in detail.

Figure 5-12 The Layer 3 Portion of CEF Relies on the FIB and Adjacency Tables

Adjacency 6b
Statistics Layer 3 Layer 2
Forwarding Forwarding
3a QoS/ACL 2a
4a Layer 2
Adjacency
3b Table
Table

2d 2b
FIB 5 ACL
Table TCAM
4b

2e 6a 2c
QoS
NoFlow
TCAM
Table
6c 1 1 7 4c
Constellation Bus Interface
NoFlow
Statistics
Data Bus
Results
Bus
1439_CCNP_3.book Page 312 Wednesday, October 27, 2004 9:54 AM

312 Chapter 5: Multilayer Switching

Step 1 The Layer 3 forwarding engine and Layer 2 forwarding engine ASICs receive
the packet headers from the data bus.
Step 2 The following operations occur in parallel:
a. The Layer 2 forwarding engine performs a lookup on the destination MAC
address.
b. The Layer 2 forwarding engine ASIC performs any necessary input secu-
rity ACL lookups.
c. The Layer 2 forwarding engine ASIC performs any necessary input QoS/
ACL lookups.
d. The Layer 3 forwarding engine ASIC performs a FIB table lookup.
e. The Layer 3 forwarding engine ASIC performs a NetFlow table lookup.
Step 3 The following operations occur in parallel:
a. The input ACL and QoS results from the Layer 2 forwarding engine ASIC
are forwarded to the Layer 3 forwarding engine ASIC.
b. The Layer 3 forwarding engine ASIC sends the destination VLAN infor-
mation for the packet to the Layer 2 forwarding engine ASIC.
Step 4 The following operations occur in parallel:
a. The Layer 3 forwarding engine ASIC performs the adjacency lookup.
b. The Layer 2 forwarding engine ASIC performs the outbound security ACL
lookup.
c. The Layer 2 forwarding engine ASIC performs the outbound QoS/ACL
lookup.
Step 5 The Layer 2 forwarding engine sends the results of the security and QoS/ACL
lookups to the Layer 3 forwarding engine ASIC.
Step 6 The following operations occur in parallel:
a. The Layer 3 forwarding engine ASIC generates the rewrite result and
sends it to the Layer 2 forwarding engine ASIC.
b. The Layer 3 forwarding engine ASIC updates the adjacency table statistics
as necessary.
c. The Layer 3 forwarding engine ASIC updates the NetFlow table statistics
as necessary.
The Layer 2 forwarding engine looks up the destination MAC address received from the
Layer 3 forwarding engine ASIC. The Layer 2 forwarding engine then chooses between a
1439_CCNP_3.book Page 313 Wednesday, October 27, 2004 9:54 AM

Cisco Express Forwarding (CEF) 313

Layer 2 and a Layer 3 result and sends the result to the results bus, an out-of-band control-
plane mechanism used for this purpose.
Figure 5-13 summarizes the CEF process with a traffic flow from a source workstation (on
the right side of the figure) to a destination workstation (on the left side of the figure). The
critical elements of the diagram are the FIB and adjacency entries of the intermediate routers
along the path. All of the IP addresses and MAC addresses referenced by the FIB and adja-
cency tables are indicated as the packet traverses the network.

Figure 5-13 Summarization of the CEF Process with Source-to-Destination Traffic Flow
Traffic Flow
172.17.9.1 172.17.9.2 172.18.8.2 172.18.8.1

E0 E1 E0 E1 E0 E1
172.16.10.1 172.19.7.2

FIB Entry FIB Entry FIB Entry


172.16.10 0/24 172.16.10 0/24 172.16.10 0/24

Nexthop Nexthop Nexthop


Connected 172.17.9.1 172.18.8.2
Destination Source:
IP Address Adjacency D base Adjacency D base Adjacency D base Sends IP Data to
172.16.10.10 172.16.10.10 - 172.17.9.1 - 172.16.8.2 - 172.16.10.10
MAC Address 0080.AB12.C821 0080.0C00.0001 0080.0C00.0002 MAC Destination
0080.AB12.C821 0800.0C00.0003
Router - 1 Router - 2 Router - 3
MAC Address or E1 - MAC Address or E1 - MAC Address or E1 -
0080.0C00.0001 0080.0C00.0002 0080.0C00.0003
IP Address of E1 - IP Address of E1 - IP Address of E1 -
172.17.9.1 172.18.8.2 172.19.7.2
IP Address of E0 - IP Address of E0 - IP Address of E0 -
172.16.10.1 172.17.9.2 172.18.8.1

Additional Benefits of CEF-Based Forwarding


In addition to the benefits just described, CEF-based forwarding provides several other
benefits:
■ Enhanced scalability
■ Availability
■ Network stability
■ Load balancing
■ ACL processing
■ Multicasting
Many of these benefits are supported only on the Catalyst 6500 series (a subset of the
Catalyst 6000 family).
1439_CCNP_3.book Page 314 Wednesday, October 27, 2004 9:54 AM

314 Chapter 5: Multilayer Switching

The following sections briefly describe some of these additional benefits.

Scalability
CEF increases scalability not only by the raw number of available FIB entries, but also by the
replication of CEF-based forwarding technology on a per-slot basis. This distributed capability
(dCEF), illustrated in Figure 5-14, allows the Catalyst 6500 series switches and Cisco 12000
series routers to provide sufficient forwarding capabilities for the largest of networks. The
Catalyst 6500 series, when equipped with a Supervisor Engine II, can provide as many as
256,000 entries in the FIB table and 256,000 entries in the adjacency table. These entries are
not stored via a traditional hashing algorithm, as is the case with MLS.

Figure 5-14 Cisco 12000 Series Routers Use Distributed CEF

Cisco 12000 Route Processor


Series Router
Running Routing Forwarding
Adjacency
Information
Distributed Table
Base
Table
CEF

IPC

Line Card Line Card Line Card

Adjacency Adjacency Adjacency


FIB FIB FIB
Table Table Table

OC-12 OC-3 FE SER T3 FDDI

Cisco 7200 Cisco 7200


GSR and Cisco 7500 and Cisco 7500
Series Routers Series Routers

Availability
Although the Catalyst 6000 family offers a breadth of features to support high availability, the
addition of CEF further increases the availability and stability demanded in today’s enterprise
networks. As networks increase in size, a natural side effect is the increased chance of insta-
bility and change. Network instability, whether caused by failures, configuration changes, or
bursty traffic patterns, can have a tremendous impact on routing implementations, which rely
on heavy CPU computations for routing-table maintenance. Because CEF employs a mechanism
by which the forwarding information is constructed based on the network topology rather
1439_CCNP_3.book Page 315 Wednesday, October 27, 2004 9:54 AM

MLS and CEF Configuration Tasks 315

than a representation of traffic within the network, the CPU is no longer burdened by having
to set up large numbers of entries. This also means that network availability is not directly
linked to the actual size of the network.

Access Control Lists


Another manner in which various CEF implementations vary is with respect to their support
of ACLs. In the case of the Catalyst 6500 series, ACLs can be handled in hardware for most
common configurations. CEF-based forwarding does not have any impact on this functionality.
The most notable ACL options that disable hardware processing for a given ACL are the use
of the log keyword or enabling “IP unreachables” on a given interface (which enables the
sending of Internet Control Message Protocol (ICMP) unreachable messages).

Multicasting
The CEF implementation on the Catalyst 6000 family also includes support for IP multicasting.
The FIB table can hold as many as 16,000 IP multicast entries.

Summary of CEF Benefits


In conclusion, CEF provides high performance and high scalability for the largest and most
demanding networks. The Supervisor Engine II offers the scalability and performance
requirements necessary for both large enterprise and service-provider environments. Cisco
has also managed to maintain the rich accounting support of the MLS model (using NetFlow
features) while introducing CEF-based forwarding.

MLS and CEF Configuration Tasks


MLS configuration involves two components: configuring the MLS-RP and configuring the
MLS-SE. CEF configuration is probably the easiest technology to configure on Cisco devices.
Configuration involves only turning on the feature, and it is on by default on most platforms
and with most newer IOS releases. This section also discusses monitoring and verifying MLS
and CEF.

MLS-RP Configuration
Configuring MLS support on an MLS-RP has five basic steps:
Step 1 Configure the MLS-RP to globally enable MLS. This is analogous to enabling
IPX or multicast routing on a router. The global configuration Cisco IOS soft-
ware command to enable MLS is mls rp ip. A Catalyst 6000 with Supervisor
Engine I and an MSFC has IP MLS globally enabled by default.
1439_CCNP_3.book Page 316 Wednesday, October 27, 2004 9:54 AM

316 Chapter 5: Multilayer Switching

Step 2 Determine which router interfaces will be used as IP MLS interfaces, and add
those interfaces to the same VLAN Trunking Protocol (VTP) domain as the
MLS-SE. Remember that router interfaces will be VLAN interfaces (not phys-
ical interfaces) on the RSM, RSFC, and MSFC. The complete syntax for the
command to add an IP MLS interface to a VTP domain is mls rp vtp-domain
[domain_name].
On ISL or 802.1Q trunks, enter the mls rp vtp-domain command on the pri-
mary interface (not on the individual subinterfaces). All subinterfaces on the
primary interface inherit the VTP domain assigned to the primary interface.
The command mls rp vtp-domain is also used on physical interfaces config-
ured as access ports (ports with only one VLAN association). On the RSFC,
RSM, and MSFC, this command is entered on each VLAN interface participat-
ing in MLS.
Step 3 For Layer 3 interfaces that are not trunk ports and on which IP MLS support is
desired, start by verifying that the interface has been assigned to a VLAN (as
an access port). Then assign a VLAN ID to the IP MLS interface with the mls
rp vlan-id [vlan_id_num] interface command.
Step 4 Enable IP MLS on the interfaces participating in IP MLS with the mls rp ip
command. This is the same command used in global configuration mode, but
here it is applied at the interface level. In the case of an ISL or 802.1Q trunk,
this command must be configured on all subinterfaces (it is not entered on the
physical interface itself). On the MSFC, RSM, and RSFC, this command is
entered on VLAN interfaces.
Step 5 Specify an MLS-RP interface as an MLS-RP management interface. MLSP
runs on the management interface, sending hello messages, advertising routing
changes, and announcing VLANs and MAC addresses of interfaces participat-
ing in MLS. At least one router interface must be configured as a management
interface (more than one is permitted, but this introduces a proportional
increase in overhead). If a management interface is not specified, IP MLS does
not function.
Also, the MLS-SE must have an active port in at least one VLAN that has a corresponding
router interface configured as a management interface. The interface command to specify an
MLS-RP interface as a management interface is mls rp management-interface, as shown in
Example 5-1. In the case of an ISL or 802.1Q trunk, this command is applied to a particular
subinterface, not to the interface itself.
1439_CCNP_3.book Page 317 Wednesday, October 27, 2004 9:54 AM

MLS and CEF Configuration Tasks 317

Example 5-1 Configuring MLS on an MLS-RP Is Fairly Complicated

! Step 1:
Router(config)#mls rpip
! Step 2:
Router(config)#interface fa2/0
Router(config-if)#mls rp vtp-domain Cisco
! Step 3: not applicable because interface fa2/0 is a trunk interface
! Step 4:
Router(config-if)#interface fa2/0.1
Router(config-subif)#encapsulation dot1q 1
Router(config-subif)#ip address 10.1.1.1 255.255.255.0
Router(config-subif)#mls rip ip
! Step 5:
Router(config-subif)#mls rp management-interface

Finally, configuring output ACLs on MLS-RP interfaces works seamlessly with MLS, mean-
ing that MLS cache entries are created that reflect the desired behavior of the ACL while still
providing wire-speed packet switching. On the other hand, input ACLs on MLS-RP interfaces
force every packet to be routed by the MLS-RP.
To enable MLS to cooperate with input ACL, enter the mls rp ip input-acl global configura-
tion command.

MLS-SE Configuration
The configuration is platform-dependent for the MLS-SE.
IP MLS is enabled by default on Catalyst 5000 family and Catalyst 2926G series switches. If
the MLS-RP is an RSM or RSFC installed in the Catalyst 5000 chassis, there is no need to
configure the switch for MLS. Configuration of the switch is required only in the following
circumstances:
■ When an external router is the MLS-RP (this is always the case with Catalyst 2926G
series switches)
■ To change the IP MLS aging time parameters or packet threshold values
■ To enable NetFlow Data Export (NDE) to monitor all IP MLS intersubnet traffic
through the NFFC
Similarly, IP MLS is enabled by default on Catalyst 6000 family switches. Recall that the
Catalyst 6000 does not support an external MLS-RP. The only options for MLS-RP are
1439_CCNP_3.book Page 318 Wednesday, October 27, 2004 9:54 AM

318 Chapter 5: Multilayer Switching

the MSM and the MSFC. Configuration of the switch is required only in the following
circumstances:
■ To specify MLS aging time parameters or packet threshold values
■ To set the minimum IP MLS flow mask
Assuming that a Catalyst 5000 or Catalyst 2926G switch (which are CatOS, or set-based,
switches) is connected to an external MLS-RP, the configuration proceeds as follows:
Step 1 Enable MLS on the switch with the set mls enable command. When IP MLS is
enabled on the switch, the switch (MLS-SE) starts to process MLSP messages
from the MLS-RPs and starts Layer 3 switching. IP MLS is enabled by default
on the MLS-SE, so this step is necessary only if MLS has been disabled with
the set mls disable command.
Step 2 Specify the external router(s) participating in MLS. Before doing so, enter the
show mls rp command on the router to identify the MLS-RP IP address. Use
the displayed address when entering the set mls include ip_addr command on
the switch, the command that specifies the external router(s) participating in
MLS. The MLS-SE does not process MLSP messages from external routers
that have not been included as MLS-RPs. Also, the MLS-SE configured in a
scenario where the MLS-RP is not an external router doesn’t need the set mls
include command, as shown in Example 5-2.

Example 5-2 Configuring MLS on an MLS-SE Requires Just One or Two Commands, Depending on Whether the
MLS-RP Is Internal or External

Switch> (enable)set mls enable


Switch> (enable)set mls include 10.1.1.1

Configuring MLS Optional Parameters


In addition to the MLS-RP and MLS-SE commands discussed up to this point, a few optional
MLS parameters are available. Two of these parameters let you configure MLS aging time
and minimum flow mask. These values can be adjusted to tune MLS efficiency.

MLS Aging Time


The IP MLS aging time determines the time before an MLS entry is aged out. The default is
256 seconds. The aging time can be configured for a value in the range of 8 to 2032 seconds,
in 8-second increments. Any aging-time value that is not a multiple of 8 seconds is adjusted
to the closest one. For example, a value of 65 is adjusted to 64, and a value of 127 is adjusted
to 128. Other events might cause MLS entries to be purged, such as routing changes or a
change in link state (MLS-SE link down).
1439_CCNP_3.book Page 319 Wednesday, October 27, 2004 9:54 AM

MLS and CEF Configuration Tasks 319

To specify the IP MLS aging time, use the CatOS set mls agingtime [agingtime] command in
privileged mode.
Another useful MLS cache aging parameter is the fast aging time. To specify the IP MLS fast
aging time and packet threshold, use the command set mls agingtime fast [fastagingtime]
[pkt_threshold] in privileged mode.
The default fastagingtime value is 0 (no fast aging). The fastagingtime value can be set to 32,
64, 96, or 128 seconds. Any fastagingtime value that is not configured exactly as the indicated
values is adjusted to the closest one. The pkt_threshold value can be set to 0, 1, 3, 7, 15, 31, or
63 packets.
Typical values for fastagingtime and pkt_threshold are 32 seconds and 0 packets (no packets
switched within 32 seconds after the entry is created).
Cisco recommends keeping the number of MLS entries in the MLS cache to less than 32,000
entries. If the number of MLS entries amounts to more than 32,000, some flows are sent to
the router.
To help keep the MLS cache size below 32,000, enable the IP MLS fast aging time. The IP
MLS fast aging time applies to MLS entries that have no more than pkt_threshold packets
switched within fastagingtime seconds after it is created. A typical cache entry that is
removed is the entry for flows to and from a Domain Name System (DNS) or TFTP server;
the entry might never be used again after it is created. Detecting and aging out these entries
saves space in the MLS cache for other data traffic.
If IP MLS fast aging time needs to be enabled, initially set the value to 128 seconds. If the
size of the MLS cache continues to grow over 32 KB, decrease the setting until the cache size
stays below 32 KB. If the cache continues to grow over 32 KB, decrease the normal IP MLS
aging time.

Minimum IP MLS Flow Mask


The minimum granularity of the flow mask for the MLS cache is configured on the MLS-SE.
The actual flow mask used consists of the granularity specified. If a more-specific flow mask
is configured, the number of active flow entries increases. To limit the number of active flow
entries, you might need to decrease the MLS aging time.
If ACLs are not configured on any MLS-RP, the IP MLS flow mask on the MLS-SE is
destination-ip by default (as discussed in the earlier section “MLS Flows”). However, an
administrator can force the MLS-SE to use a particular flow mask granularity by setting the
minimum IP MLS flow mask using the set mls flow {destination | destination-source | full}
command in privileged mode (again, these are CatOS commands). Depending on the MLS-RP
configuration, the actual flow mask used might be more specific than the specified minimum
1439_CCNP_3.book Page 320 Wednesday, October 27, 2004 9:54 AM

320 Chapter 5: Multilayer Switching

flow mask. For example, if the minimum flow mask of destination-source is configured, but
an MLS-RP interface is configured with IP extended ACLs, the actual flow mask used is
full (ip-flow).
The set mls flow command purges all existing MLS cache entries and affects the number of
active entries on the MLS-SE, so use this command carefully when applying it to a produc-
tion environment.

MLS Configuration Example


This example details the configuration of IP MLS for the topology shown in Figure 5-15.

Figure 5-15 A 7505 Router (MLS-RP) Connects Via an 802.1Q Trunk to an MLS-SE (a Catalyst 5509
with a Supervisor Engine III and NFFC in This Case)

Cisco 7505
(MLS-RP) Subinterface:
fa2/0.1 10.1.1.1
fa2/0 10 10 1.10.1
fa2/0.20 10.1.20.1 Source S2
fa2/0 fa2/0.30 10.1.30.1 10.1.30.201
Catalyst 5509
Catalyst 5505 with NFFC IEEE 802.1Q Catalyst 5505
(Switch A, MLS-SE) Trunk Link 4/1
(Switch B) (Switch C)
3/1 1/1 1/2 1/3 1/1

IEEE 802.1Q IEEE 802.1Q


3/1
Source S1 Trunk Link Trunk Link 3/1
10.1.10.100
Destination D1
10.1.30.200
Destination D2
VLAN 10 10.1.20.200
Subnet 10.1.10.0/24 VLAN 30
VLAN 20
Subnet 10.1.30.0/24
Subnet 10.1.20.0/24

A Cisco 7505 router serves as the MLS-RP, and a Catalyst 5509 with a Supervisor Engine III
and an NFFC (Switch A) serves as the MLS-SE. An IEEE 802.1Q trunk connects the two
devices participating in MLS.
The IP MLS network topology shown in Figure 5-15 includes two Catalyst 5505 switches
connecting via 802.1Q trunks to the MLS-SE (Switch B and Switch C). The 5505s do not
play a role in MLS. The network is configured as follows:
■ There are four VLANs (IP subnetworks):
— VLAN 1 (the management VLAN), subnet 10.1.1.0/24
— VLAN 10, subnet 10.1.10.0/24
— VLAN 20, subnet 10.1.20.0/24
— VLAN 30, subnet 10.1.30.0/24
1439_CCNP_3.book Page 321 Wednesday, October 27, 2004 9:54 AM

MLS and CEF Configuration Tasks 321

■ The MLS-RP is a Cisco 7505 router with a Fast Ethernet interface (interface
FastEthernet 2/0)
■ The subinterfaces on the router interface have these IP addresses:
— FastEthernet 2/0.1—10.1.1.1 255.255.255.0
— FastEthernet 2/0.10—10.1.10.1 255.255.255.0
— FastEthernet 2/0.20—10.1.20.1 255.255.255.0
— FastEthernet 2/0.30—10.1.30.1 255.255.255.0
■ A standard output ACL is configured on subinterface FastEthernet 2/0.20 (the interface
in VLAN 20) on the MLS-RP. The ACL denies all traffic from VLAN 30.
■ Switch A, the MLS-SE, is a Catalyst 5509 switch with Supervisor Engine III and
the NFFC.
■ Switch B and Switch C are Catalyst 5505 switches.
■ Switch A is the VTP server in domain “Corporate.”
■ Switch B and Switch C are VTP clients.
The next sections detail the inter-VLAN switching path both before and after IP MLS
operation.

Operation Before IP MLS


The operation before IP MLS operation is characterized as follows:
1. Before IP MLS is implemented, when the source host S1 (on VLAN 10) transmits
traffic destined for server D1 (on VLAN 30), Switch B forwards the traffic (based on
the Layer 2 forwarding table) to Switch A over the 802.1Q trunk link.
2. Switch A forwards the packet to the router over the 802.1Q trunk.

3. The router receives the packet on the VLAN 10 subinterface, checks the destination
IP address, and routes the packet to the VLAN 30 subinterface.
4. Switch A receives the routed packet and forwards it to Switch C.

5. Switch C receives the packet and forwards it to destination server D1. This process is
repeated for each packet in the flow between source host S1 and destination server D1.
6. When source host S2 sends traffic to destination server D2, Switch C forwards the
packets over the 802.1Q trunk to Switch A.
7. Switch A forwards the packet to the MLS-RP.
1439_CCNP_3.book Page 322 Wednesday, October 27, 2004 9:54 AM

322 Chapter 5: Multilayer Switching

8. The MLS-RP receives the packet on the VLAN 30 subinterface. Because the standard
ACL configured on the outgoing VLAN 20 subinterface denies all traffic from VLAN 30,
the router drops the traffic to Destination D2 from Source S2.
9. Any subsequent traffic from Source S2 for Destination D2 also reaches the router and is
dropped.

Operation After IP MLS


The operation after IP MLS operation is characterized as follows:
1. After IP MLS is implemented, when the source host S1 transmits traffic destined for
destination server D1, Switch B forwards the traffic (based on the Layer 2 forwarding
table) to Switch A (the MLS-SE) over the 802.1Q trunk link.
2. When the first packet enters Switch A, a candidate flow entry is established in the MLS
cache. Switch A forwards the packet to the MLS-RP over the 802.1Q trunk.
3. The MLS-RP receives the packet on the VLAN 10 subinterface, checks the destination
IP address, and routes the packet to the VLAN 30 subinterface.
4. Switch A receives the routed packet (the enable packet) and completes the flow entry in
the MLS cache for destination IP address 10.1.30.200. Switch A forwards the packet to
Switch C, where it is forwarded to destination server D1.
5. Subsequent packets destined for IP address 10.1.30.200 are multilayer-switched by the
MLS-SE based on the flow entry in the MLS cache. For example, subsequent packets in
the flow from source host S1 are forwarded by Switch B to Switch A (the MLS-SE).
The MLS-SE determines that the packets are part of the established flow, rewrites the
packet headers, and switches the packets directly to Switch C, bypassing the router.
Because a standard ACL is applied on subinterface FastEthernet 2/0.20, the MLS-SE must
use the source-destination-ip flow mask for all MLS cache entries. When source host S2
sends traffic to destination server D2, Switch C forwards the packets over the 802.1Q trunk to
Switch A. Switch A forwards the candidate packet to the MLS-RP, which receives it on the
VLAN 30 subinterface. Because the standard ACL configured on the outgoing VLAN 20 sub-
interface denies all traffic from VLAN 30, the router drops the traffic to Destination D2 from
Source S2. Switch A never receives the enable packet for the flow on VLAN 20, and no MLS
cache entry is completed for the flow. Any subsequent traffic from Source S2 for Destination
D2 also reaches the router and is dropped.
1439_CCNP_3.book Page 323 Wednesday, October 27, 2004 9:54 AM

MLS and CEF Configuration Tasks 323

MLS-RP Configuration
Example 5-3 shows the MLS-RP configuration for the network shown in Figure 5-15, using
the five steps outlined in the earlier section “MLS-RP Configuration.”

Example 5-3 The MLS-RP Configuration on the 7505 Router Is the Hardest Part of the MLS Configuration

! MLS-RP Step 1:
Cisco7505(config)#mls rip ip
Cisco7505(config)#access-list 1 deny 10.1.30.0 0.0.0.255
Cisco7505(config)#access-list 1 permit any
Cisco7505(config-if)#interface fastethernet 2/0
Cisco7505(config-if)#speed 100
Cisco7505(config-if)#full-duplex
! MLS-RP Step 2:
Cisco7505(config-if)#mls rp vtp-domain Corporate
Cisco7505(config-subif)#interface fastethernet2/0.1
Cisco7505(config-subif)#encapsulation dot1q 1
Cisco7505(config-subif)#ip address 10.1.1.1 255.255.255.0
! MLS-RP Step 4:
Cisco7505(config-subif)#mls rp ip
! MLS-RP Step 5:
Cisco7505(config-subif)#mls rp management interface
Cisco7505(config-subif)#interface fastethernet2/0.10
Cisco7505(config-subif)#encapsulation dot1q 10
Cisco7505(config-subif)#ipo address 10.1.10.1 255.255.255.0
! MLS-RP Step 4:
Cisco7505(config-subif)#mls rip ip
Cisco7505(config-subif)#encapsulation dot1q 20
Cisco7505(config-subif)#ip address 10.1.20.1 255.255.255.0
Cisco7505(config-subif)#ip access-group 1 out
! MLS-RP Step 4:
Cisco7505(config-subif)#mls rp ip
Cisco7505(config-subif)#interface fastethernet2/0.30
Cisco7505(config-subif)#encapsulation dot1q 30
Cisco7505(config-subif)#ip address 10.1.30.1 255.255.255.0
! MLS-RP Step 4:
Cisco7505(config-subif)#mls rip ip
1439_CCNP_3.book Page 324 Wednesday, October 27, 2004 9:54 AM

324 Chapter 5: Multilayer Switching

Switch A, B, and C Configuration


In some Cisco IOS software releases, traffic on the IEEE 802.1Q native VLAN is not routed.
The default native VLAN on Catalyst switches is VLAN 1. If the Cisco IOS software release
being used does not route traffic on the native VLAN and an administrator wants to route traf-
fic on VLAN 1, he or she must change the native VLAN on the switch-to-router trunk link to
an unused VLAN. In the Switch A, Switch B, and Switch C configuration examples, the native
VLAN on all the 802.1Q trunk links is set to an unused VLAN: VLAN 5.
Example 5-4 shows the configuration for Switch A, Example 5-5 shows the configuration for
Switch B, and Example 5-6 shows the configuration for Switch C.

Example 5-4 The Catalyst 5509 Is the MLS-SE

SwitchA>(enable) set vtp domain Corporate mode server


VTP domain Corporate modified
SwitchA>(enable) set vlan 5
Vlan 5 configuration successful
SwitchA>(enable) set vlan 10
Vlan 10 configuration successful
SwitchA>(enable) set vlan 20
Vlan 20 configuration successful
SwitchA>(enable) set vlan 30
Vlan 30 configuration successful
SwitchA>(enable) set trunk 1/1 on dot1q
Port(s) 1/1 trunk mode set to on.
Port(s) 1/1 trunk type set to dot1q
SwitchA>(enable) set port name 1/2 SwitchBLink
Port 1/2 name set.
SwitchA>(enable) set trunk 1/2 desirable dot1q
Port(s) 1/2 trunk mode set to desirable
Port(s) 1/2 trunk type set to dot1q
SwitchA>(enable) set port name 1/3 SwitchCLink
Port 1/3 name set
SwitchA>(enable) set trunk 1/3 desirable dot1q
Port(s) 1/3 trunk mode set to desirable
Port(s) 1/3 trunk type set to dot1q
SwitchA>(enable) set vlan 5 1/1-3
VLAN 5 modified
VLAN 1 modified
1439_CCNP_3.book Page 325 Wednesday, October 27, 2004 9:54 AM

MLS and CEF Configuration Tasks 325

Example 5-4 The Catalyst 5509 Is the MLS-SE (Continued)

VLAN Mod/Ports
---- ---------
5 1/1-3
! MLS-SE Step 1:
SwitchA>(enable) set mls enable
IP Multilayer switching is enabled
! MLS-SE Step 2:
SwitchA>(enable) set mls include 10.1.1.1
IP Multilayer switching enabled for router 10.1.1.1
SwitchA>(enable) set port name 3/1 DestinationD2
Port 3/1 name set.
SwitchA>(enable) set vlan 20 3/1

Example 5-5 Switch B is a Catalyst 5505 Switch

SwitchB>(enable) set port name 1/1 SwitchALink


Port 1/1 name set
SwitchB>(enable) set vlan 5 1/1
VLAN 5 modified
VLAN 1 modified
VLAN Mod/Ports
---- ---------
5 1/1
SwitchB>(enable) set vlan 10 3/1
VLAN 10 modified
VLAN 1 modified
VLAN Mod/Ports
---- ---------
10 3/1

Example 5-6 Switch C is a Catalyst 5505 Switch

SwitchC>(enable) set port name 1/1 SwitchALink


Port 1/1 name set
SwitchC>(enable) set vlan 5 1/1
VLAN 5 modified
VLAN 1 modified
continues
1439_CCNP_3.book Page 326 Wednesday, October 27, 2004 9:54 AM

326 Chapter 5: Multilayer Switching

Example 5-6 Switch C is a Catalyst 5505 Switch (Continued)

VLAN Mod/Ports
---- ---------
5 1/1
SwitchC>(enable) set port name 3/1 DesintationD1
Port 3/1 name set
SwitchC>(enable) set vlan 30 3/1
VLAN 30 modified
VLAN 1 modified
VLAN Mod/Ports
---- ---------
30 3/1
SwitchC>(enable) set port name 4/1 SourceS2
Port 4/1 name set
SwitchC>(enable) set vlan 30 4/1
VLAN 30 modified
VLAN 1 modified
VLAN Mod/Ports
---- ---------
30 3/1
4/1

MLS Verification
The show mls rp command displays the following information:
■ Whether MLS switching is globally enabled or disabled
■ The MLS ID for this MLS-RP
■ The MLS IP address for this MLS-RP
■ The MLS flow mask
■ The name of the VTP domain in which the MLS-RP interfaces reside
■ Statistical information for each VTP domain
■ The number of management interfaces defined for the MLS-RP
■ The number of VLANs configured for MLS
■ The ID of each VLAN configured for this MAC address
■ The number of MLS-SEs to which the MLS-RP is connected
■ The MAC address of each switch
1439_CCNP_3.book Page 327 Wednesday, October 27, 2004 9:54 AM

MLS and CEF Configuration Tasks 327

Each MLS-RP is identified to the switch by both the MLS ID and the MLS IP address of the
route processor. The MLS ID is the MAC address of the route processor. The MLS-RP auto-
matically selects the IP address of one of its interfaces from MLS-enabled interfaces and uses
that IP address as its MLS IP address.
The MLS-SE uses the MLS ID in the process of populating the MLS cache. This MLS IP
address is used in the following situations:
■ By the MLS-RP and the MLS-SE when sending MLS statistics to a data collection
application
■ In the included MLS-RP list on the switch
To display IP MLS information about a specific interface, use the show mls rp interface type
number command. Example 5-7 shows the output of this command for interface VLAN 10.

Example 5-7 Displaying Specific Information for an IP MLS Interface

Router#show mls rp interface vlan 10


als active on Vlan10, domain Corporate
Router#

The show mls rp vtp-domain domain-name command displays IP MLS information for a
specific VTP domain on the MLS-RP, as shown in Example 5-8.

Example 5-8 Displaying IP MLS Information Specific to a VTP Domain

Router#show mls rp vtp-domain Corporatevlan domain name: Corporate


current flow mask: ip-flow
current sequence number: 80709115
current/maximum rety count: 0/10
current domain state: no-change
current/next global purge: false/false
current/next purge count: 0/1
domain uptime: 13:07:36
keepalive timer expires in 8 seconds
retry timer not running
change timer not running
fcp subblock count = 7
1 management interface(s) current defined: vlan 1 on Vlan1
7 mac-vlan(s) configured for multi-layer switching: mac 00e0.fefc.6000
continues
1439_CCNP_3.book Page 328 Wednesday, October 27, 2004 9:54 AM

328 Chapter 5: Multilayer Switching

Example 5-8 Displaying IP MLS Information Specific to a VTP Domain (Continued)

vlan id(s)
1 10 91 92 93 95 100
router currently aware of following 1 switch(es):
switch id 0010.1192.b5ff

On the Catalyst 6000 MSFC, the show mls status command displays basic MLS informa-
tion, as shown in Example 5-9.

Example 5-9 Displaying Basic MLS Information on a Catalyst 6000 Family Switch MSFC

Router#show mls status


MLS global configuration status:
global mls ip: enabled
global mls ipx: enabled
global mls ip multicast: disabled
current ip flowmask for unicast: destination only
current ipx flowmask for unicast: destination only
Router#

The show mls output provides the following information:


■ Whether MLS is enabled on the switch
■ The aging time, in seconds, for an MLS cache entry
■ The fast aging time, in seconds, and the packet threshold for a flow
■ The flow mask
■ Total packets switched
■ The number of active MLS entries in the cache
■ Whether NetFlow data export is enabled and, if so, for which port and host
■ The MLS-RP IP address, MAC address, XTAG, and supported VLANs
To display MLS information on an MLS-SE, enter the show mls command in privileged
mode. Example 5-10 shows the results of this command.

Example 5-10 Displaying MLS Information on an MLS-SE Running Catalyst OS

Console>(enable) show mls

Multilayer switching enabled


Multilayer switching aging time = 256 seconds
1439_CCNP_3.book Page 329 Wednesday, October 27, 2004 9:54 AM

MLS and CEF Configuration Tasks 329

Example 5-10 Displaying MLS Information on an MLS-SE Running Catalyst OS (Continued)

Multilayer switching fast aging time = 0 seconds, packet threshold = 1


Desintation-ip flow
Total packets switched = 101892
Active entries = 2153
Netflow data export enabled
Netflow data export configured for port 8010 on host 10.0.2.15
Total packets exported = 20

MLS-RIP IP MLS-Rp ID Xtag MLS-RP MAC-Vlans


------------------------ ---- --------------------------
172.20.25.2 00008080cece 2 00-00-80-ec-e0 1-20
00-00-80-ec-e1 21-30
00-00-80-ec-e2 31-40
00-00-80-ec-e3 41-50
00-00-80-ec-e4 51-60

172.20.27.1 00008080cece 3 00-00-80-12-14 1-20, 31-40


00-00-80-12-15 21-30
00-00-80-12-16 41-50

To display information about a specific MLS-RP, enter the show mls rp [ip_addr] command.
This command displays information used by the switch with regard to Layer 3 switched
packets, as demonstrated in Example 5-11.

Example 5-11 Displaying MLS-RP Information on an MLS-SE Running Catalyst OS

Console>(enable) show mls rp 166.122.20.2

MLS-RP IP MLS-Rp ID Xtag MLS-RP MAC-Vlans


------------------------ ---- -------------------------
166.122.20.2 00008080cece 2 00-00-80-ec-e0 1-20
00-00-80-ec-e1 21-30
00-00-80-ec-e2 31-40
00-00-80-ec-e3 41-50
00-00-80-ec-e4 51-60
1439_CCNP_3.book Page 330 Wednesday, October 27, 2004 9:54 AM

330 Chapter 5: Multilayer Switching

Arguably, the most useful show commands for MLS are those that display the MLS cache
entries or that use the show mls entry command or one of its four variations:
■ show mls entry rp
■ show mls entry destination
■ show mls entry source
■ show mls entry flow
To display all MLS entries on the switch, simply enter the command show mls entry, or use
an option to get more specific information, as shown in Example 5-12.

Example 5-12 Displaying MLS Cache Entries on an MLS-SE Running Catalyst OS

Console>(enable) show mls entry destination 172.20.22.14/24

Destination IP Source IP Port DstPrt SrcPrt Destination Mac Vlan Port

MLS-RP 172.20.25.1:
172.20.22.14 172.20.25.10 TCP 6001 Telnet 00-60-700-6c-fc-22 4 2/1
MLS-RP 172.20.25.1:
172.20.22.16 172.20.27.139 TCP 6001 Telnet 00-60-700-6c-fc-24 4 2/3

Finally, just as an administrator occasionally needs to clear ARP cache entries, content-
addressable memory (CAM), or the routing table, sometimes there is a need to remove entries
from the MLS cache. To do so, enter the clear mls entry command. Here’s the full syntax of
this command when used for IP flows:
clear mls entry ip [destination ip_addr_spec] [source ip_addr_spec]
[flow protocol src_port dst_port] [all]

The all keyword clears all MLS entries. Other than the all keyword option, the syntax parallels
that of the show mls entry command. Example 5-13 shows the output of a prescriptive use of
the clear mls entry ip command.

Example 5-13 Removing MLS Cache Entries on an MLS-SE Running Catalyst OS

Console>(enable) clear mls entry ip destination 172.20.26.22 source


172.20.22.113
flow tcp 1652 23

MLS IP entry cleared


1439_CCNP_3.book Page 331 Wednesday, October 27, 2004 9:54 AM

MLS and CEF Configuration Tasks 331

CEF Configuration and Verification


CEF configuration is straightforward. However, there are many options for verifying and
monitoring CEF operation.

CEF Configuration
One of CEF’s most appealing features might be its configuration. CEF for PFC2 on a
Catalyst 6500 is permanently enabled on Supervisor Engine II with the PFC2 and MSFC2,
so no configuration is required. However, some platforms allow CEF to be disabled or don’t
default to enabling CEF.
On Catalyst 3550 switches, CEF is enabled globally by default. If for some reason it is dis-
abled, you can reenable it by using the ip cef global configuration command.
To enable dCEF on line cards so that the route processor can handle routing protocols or
switch packets from legacy interface processors, issue the ip cef distributed global configu-
ration command.
When CEF or dCEF is enabled globally, all interfaces that support CEF are enabled by
default.
An administrator might want to disable CEF or dCEF on a particular interface, because that
interface is configured with a feature that CEF or dCEF does not support. For example, policy
routing and CEF cannot be used together. Sometimes one interface is configured to support
policy routing and the other interfaces support CEF. In this case, enable CEF globally, but
disable it on the interface configured for policy routing. This allows all but one interface to
express forward.
To disable CEF or dCEF on an interface, use the no ip route-cache cef command in interface
configuration mode.
When CEF or dCEF is disabled, Cisco IOS software switches packets using the next fastest
switching path. In the case of dCEF, the next fastest switching path is CEF on the route pro-
cessor. If CEF or dCEF is disabled on an interface, an administrator can reenable it by using
the ip route-cache cef command while in interface configuration mode.

Verifying CEF
You can view the contents of the FIB table by issuing the show ip cef detail command from
the MSFC2 or Supervisor Engine 720. Example 5-14 shows the output from this command.
1439_CCNP_3.book Page 332 Wednesday, October 27, 2004 9:54 AM

332 Chapter 5: Multilayer Switching

Example 5-14 Displaying the FIB Table on a Catalyst 6500 MSFC2 or Supervisor Engine 720

MSFC2#show ip cef detail


IP CEF with switching (Table Version 477965)
445 routes, 0 reresolve, 0 unresolved (0 old, 0 new)
446 leaves, 76 nodes, 132560 bytes, 477966 inserts, 477520 invalidations
0 load sharing elements, 0 bytes, 0 references
1 CEF resets, 2 revisions of existing leaves
refcounts: 15824 leaf, 15038 node
Default 192.35.86.0/24
0.0.0.0/32, version 0, receive
10.1.0.0/16, version 121980, attached, connected
0 packets, 0 bytes
via Vlan10, 0 dependencies
valid glean adjacency
10.1.0.0/32, version 121982, recieve
10.1.0.44/32, version 433624, connected, cached adjacency
10.1.0.44
0 packets, 0 bytes
via 10.1.0.44, Vlan10, 0 dependencies
next hop 10.1.0.44, Vlan10
valid cached adjacency
10.1.0.84/32, version 122675, connected, cached adjacency
10.1.0.84
0 packets, 0 bytes
via 10.1.0.84, Vlan10, 0 dependencies
next hop 10.1.0.84, Vlan10
valid cached adjacency
10.1.0.107/32, version 471278, connected, cached
adjacency 10.1.0.107
0 packets, 0 bytes
via 10.1.0.107, Vlan10, 0 dependencies
next hop 10.1.0.107, Vlan10
valid cached adjacency
10.1.0.152/32, version 450780, connected, cached
adjacency 10.1.0.152
0 packets, 0 bytes
via 10.1.0.152, Vlan10, 0 dependencies
1439_CCNP_3.book Page 333 Wednesday, October 27, 2004 9:54 AM

MLS and CEF Configuration Tasks 333

Example 5-14 Displaying the FIB Table on a Catalyst 6500 MSFC2 or Supervisor Engine 720 (Continued)

next hop 10.1.0.152, Vlan10


valid cached adjacency
10.1.0.158/32, version 447262, connected, cached
adjacency 10.1.0.158
0 packets, 0 bytes
via 10.1.0.158, Vlan10, 0 dependencies
next hop 10.1.0.158, Vlan10
valid cached adjacency
10.1.0.162/32, version 471313, connected, cached
adjacency 10.1.0.162
0 packets, 0 bytes
via 10.1.0.162, Vlan10, 0 dependencies
next hop 10.1.0.162, Vlan10
valid cached adjacency
<output omitted>

Use the show ip cef command to view the contents of the CEF adjacency table from the
MSFC2 or Supervisor Engine 720, as shown in Example 5-15. The show ip cef summary
command, shown in Example 5-16, provides a brief overview of the CEF process with infor-
mation such as the total number of adjacencies and routes.

Example 5-15 Displaying the Contents of the CEF Adjacency Table on a Catalyst 6500 MSFC2 or Supervisor
Engine 720

MSFC2#show ip cef
0.0.0/32 receive
10.1.0.0/16 attached Vlan10
10.1.0.0/32 receive
10.1.0.44/32 10.1.0.44 Vlan10
10.1.0.84/32 10.1.0.84 Vlan10
10.1.0.107/32 10.1.0.107 Vlan10
10.1.255.253/32 10.1.255.253 Vlan10
10.1.255.254/32 receive
10.1.255.255/32 receive
10.2.0.0/16 attached Vlan2
10.2.0.0/32 receive
10.2.0.12/32 10.2.0.12 Vlan2
1439_CCNP_3.book Page 334 Wednesday, October 27, 2004 9:54 AM

334 Chapter 5: Multilayer Switching

Example 5-16 Displaying a Brief Overview of the CEF Process on a Catalyst 6500 MSFC2 or Supervisor
Engine 720

MSFC2#show ip cef summary


IP CEF with switching (Table Version 477965)
445 routes, 0 reresolve, 0 unresolved (0 old, 0 new)
446 leaves, 76 nodes, 132560 bytes, 477966 inserts, 477520 invalidations
0 load sharing elements, 0 bytes, 0 references
1 CEF resets, 2 revisions of existing leaves
refcounts: 15824 leaf, 15038 node
Default 192.35.86.0/24

Lab 5.4.1 Monitoring Cisco Express Forwarding


In this lab exercise, you monitor the default behavior of CEF.

Summary
MLS and CEF are Cisco multilayer switching technologies. CEF is newer than MLS and is
supported by all the newer devices, such as the Catalyst 4000 Supervisor Engine III and IV,
the Catalyst 6500 with MSFC2 and PFC2, the Catalyst 6500 Supervisor Engine 720, and
Cisco routers with Cisco IOS software Release 12.2 and later. CEF has been supported on
some routers since Cisco IOS software Release 12.0, such as the Cisco 7500.
1439_CCNP_3.book Page 335 Wednesday, October 27, 2004 9:54 AM

Key Terms 335

Key Terms
adjacency table One of three tables used by CEF. The adjacency table is a database of node
adjacencies (two nodes are said to be adjacent if they can reach each other via a single Layer 2
hop) and their associated Layer 2 MAC rewrite or next-hop information. Each leaf of the FIB
tree offers a pointer to the appropriate next-hop entry in the adjacency table.
aging time The IP MLS aging time determines the amount of time before an MLS entry is
aged out. The default is 256 seconds. You can configure the aging time in the range of 8 to
2032 seconds in 8-second increments.
candidate packet When a source initiates a data transfer to a destination, it sends the first
packet to the MLS-RP through the MLS-SE. The MLS-SE recognizes the packet as a candi-
date packet for Layer 3 switching, because the MLS-SE has learned the MLS-RP’s destina-
tion MAC addresses and VLANs through MLSP. The MLS-SE learns the candidate packet’s
Layer 3 flow information (such as the destination address, source address, and protocol port
numbers) and forwards the candidate packet to the MLS-RP. A partial MLS entry for this
Layer 3 flow is created in the MLS cache.
central rewrite engine The Catalyst 5000 NFFC contains central rewrite engines (one per
bus) to handle PDU header rewrites when inline rewrite is not an option. If the central rewrite
engines are used, this means that a frame must traverse the bus twice—first with a VLAN tag
for the source (on its way to the NFFC) and second with a VLAN tag for the destination (on
its way to the egress port).
Cisco Express Forwarding (CEF) A Cisco multilayer switching technology that allows for
increased scalability and performance to meet the requirements for large enterprise networks.
CEF has evolved to accommodate the traffic patterns realized by modern networks, character-
ized by an increasing number of short-duration flows.
Content-Addressable Memory (CAM) Memory that is accessed based on its contents, not
on its memory address. Sometimes called associative memory.
enable packet When an MLS-SE receives a packet from the MLS-RP that originated as a
candidate packet, it recognizes that the source MAC address belongs to the MLS-RP, that the
XTAG matches that of the candidate packet, and that the packet’s flow information matches
the flow for which the candidate entry was created. The MLS-SE considers this packet an
enable packet and completes the MLS entry created by the candidate packet in the MLS
cache.
fast aging time The IP MLS fast aging time is the amount of time before an MLS entry is
purged that has no more than pkt_threshold packets switched within fastagingtime seconds
after it is created.
1439_CCNP_3.book Page 336 Wednesday, October 27, 2004 9:54 AM

336 Chapter 5: Multilayer Switching

flow A unidirectional sequence of packets between a particular source and destination that
share the same Layer 3 and Layer 4 PDU header information.
flow mask A set of criteria, based on a combination of source IP address, destination IP
address, protocol, and protocol ports, that describes the characteristics of a flow.
Forwarding Information Base (FIB) One of three tables used by CEF. The FIB table con-
tains the minimum information necessary to forward packets; in particular, it does not contain
any routing protocol information. The table consists of a four-level hierarchical tree, with 256
branch options per level (reflecting four octets in an IP address).
inline rewrite Some Catalyst 5000 family switch line cards have onboard hardware that
performs PDU header rewrites and forwarding, maximizing IP MLS performance. When the
line card performs the PDU header rewrites, this is called inline rewrite. With inline rewrite,
frames traverse the switch bus only once.
MLS Route Processor (MLS-RP) A Cisco device with a route processor that supports
MLS. For example, a Catalyst 3620 router is an MLS-RP.
MLS Switching Engine (MLS-SE) A set of hardware components on a Catalyst switch,
excluding the route processor, necessary to support MLS. For example, a Catalyst 5000 with
a Supervisor Engine IIIG is an MLS-SE.
MLS-RP Management Interface The MLS-RP interface that sends hello messages, adver-
tises routing changes, and announces VLANs and MAC addresses of interfaces participating
in MLS.
Multilayer Switch Feature Card (MSFC) MSFC1 and MSFC2 are daughter cards to the
Catalyst 6000 Supervisor Engine that provide multilayer switching functionality and routing
services between VLANs.
Multilayer Switching (MLS) A specific multilayer switching technology employed by var-
ious Cisco devices to perform wire-speed PDU header rewrites. The first packet in a flow is
routed as normal, and the MLS-SE switches subsequent packets based on cached information.
Multilayer Switching Protocol (MLSP) A protocol used to communicate MLS information
between the MLS-SE and MLS-RP. In particular, the MLS-SE populates its Layer 2 CAM
table with updates received from MLSP packets.
NetFlow Feature Card (NFFC) A daughter card for a Catalyst 5000 Supervisor module
that enables intelligent network services, such as high-performance multilayer switching and
accounting and traffic management.
NetFlow table One of three tables used by CEF. The NetFlow table provides network
accounting data. It is updated in parallel with the CEF-based forwarding mechanism provided
by the FIB and adjacency tables.
1439_CCNP_3.book Page 337 Wednesday, October 27, 2004 9:54 AM

Check Your Understanding 337

wire-speed routing The routing of packets using a combination of hardware and data struc-
tures so that routing table lookups are circumvented and header rewrites and forwarding are
handled independent of the route processor.
XTAG A 1-byte value that the MLS-SE attaches per VLAN to all MAC addresses learned
from the same MLS-RP via MLSP.

Check Your Understanding


Use the following review questions to test your understanding of the concepts covered in this
chapter. Answers are listed in Appendix A, “Check Your Understanding Answer Key.”
1. Which of the following describe multilayer switching?

A. It’s hardware-based.

B. It performs PDU header rewrites and forwarding.

C. It’s platform-independent.

D. It uses Layer 2, Layer 3, and Layer 4 header information.


2. Which of the following device combinations support Cisco Express Forwarding?

A. Cisco 7500 router running IOS 12.0

B. Catalyst 4500 Supervisor Engine III

C. Catalyst 6500 MSFC2

D. Cisco routers running IOS 12.2 or later


3. Which of the following are MLS components?

A. MLSP

B. MLS-RP

C. MLS cache

D. MLS-SE
4. Which of the following are MLS flow masks?

A. destination-ip

B. protocol-flow

C. source-destination-ip

D. ip-flow
1439_CCNP_3.book Page 338 Wednesday, October 27, 2004 9:54 AM

338 Chapter 5: Multilayer Switching

5. After an IP MLS flow has been created, which of the following fields change in a frame
traversing the MLS-SE as part of the same flow?
A. Source MAC address

B. Destination MAC address

C. TTL

D. Source IP
6. In addition to the routing table, what tables are created in the CEF-based model?

A. Routing table

B. Forwarding Information Base

C. Content-flow table

D. Adjacency table
7. How many leaves are possible in a CEF FIB?

A. 32

B. 64

C. 128

D. 256
8. How many MLS-SE commands are required to configure MLS when the MLS-RP is an
external router?
A. 1

B. 2

C. 3

D. 4
9. What is the default MLS flow mask when no ACLs are configured on the MLS-RP?

A. destination-ip

B. protocol-flow

C. source-destination-ip

D. ip-flow
1439_CCNP_3.book Page 339 Wednesday, October 27, 2004 9:54 AM

Check Your Understanding 339

10. What global configuration command enables CEF?

A. cef run

B. enable cef

C. cef enable

D. ip cef
1439_CCNP_3.book Page 340 Monday, November 1, 2004 11:16 AM

Objectives
After completing this chapter, you will be able to perform tasks related to the following:
■ Explain the types of redundancy in a multilayer switched network, including hardware
and software redundancy
■ Implement redundant Supervisor modules in Catalyst switches
■ Implement redundant Supervisor uplink modules in Catalyst switches
■ Implement redundant distributed forwarding cards in Catalyst switches
■ Explain how router redundancy operates
■ Describe, configure, and verify Hot Standby Router Protocol (HSRP)
■ Describe Virtual Router Redundancy Protocol (VRRP)
■ Describe and verify Gateway Load Balancing Protocol (GLBP)
■ Describe Single Router Mode (SRM) redundancy
■ Describe and verify Server Load Balancing (SLB)
■ Troubleshoot router redundancy using HSRP, VRRP, GLBP, SRM, and SLB
1439_CCNP_3.book Page 341 Wednesday, October 27, 2004 9:54 AM

Chapter 6

Redundancy
Because many organizations are now seeking the economic benefits of campus networks for
mission-critical communications, high reliability is becoming increasingly crucial. Within the
campus network, much attention has been focused on providing a network infrastructure that is
available 100 percent of the time. One of the greatest challenges comes not from the network
infrastructure but from the workstations and network equipment at the user level.
High network availability rates rely on two key items:
■ Elimination of any single point of failure
■ Distribution of intelligence throughout the architecture
Availability can be increased by adding redundant components, including redundant network
devices and connections to multiple WAN links, as illustrated in Figure 6-1. With the proper
design, no single point of failure affects overall system availability.
The best practice is a design based on modular and hierarchical building blocks that can be rep-
licated to support growth. The infrastructure must also be able to detect and respond quickly to
any possible service, link, device, server, or software failure. Users and applications do not
notice failures, because optimized resiliency technologies ensure fast convergence upon failure.
To achieve optimal, fast convergence, multiple networking technologies need to interoperate and
complement each other to ensure fast recovery.
The objective of this chapter is to provide an overview of hardware and software redundancy
operation and implementation on the Cisco Catalyst series of switches. The Cisco-proprietary
Hot Standby Router Protocol (HSRP) feature is the main focus of this module. Other redundancy
technologies, such as Virtual Router Redundancy Protocol (VRRP), Gateway Load Balancing
Protocol (GLBP), and Server Load Balancing (SLB) are also explored.
1439_CCNP_3.book Page 342 Wednesday, October 27, 2004 9:54 AM

342 Chapter 6: Redundancy

Figure 6-1 A Well-Designed Network Always Includes Redundancy

Cache Engine
Distributed Distributed
Cisco Secure Director Director
PIX Firewall

ISP 1
Alternate
Internet Commerce
Corporate ISP 2 Site
Network

Local
Director
Catalyst
6500
Web
Servers
Database
Servers

Implementing Module Redundancy in a Multilayer


Switched Network
Hardware redundancy takes on many presentations with Cisco Catalyst switches. These
include redundant Supervisor Engines, redundant uplink modules, redundant forwarding
cards, and redundant power supplies. This section details each of these options.

Implementing Redundant Supervisor Engines in


Catalyst Switches
The Catalyst 6000 family switches rely on a Supervisor Engine to manage the other modules
in the chassis, as shown in Figure 6-2. Dual Supervisor Engines provide hardware redundancy
for the forwarding intelligence of the Catalyst 6000 family. Catalyst 6000 family switches
can support two Supervisor Engine I or II modules only in slots 1 and 2. The Catalyst 6500
can support two Supervisor Engine 720 modules only in slots 1 and 2 in a three-slot chassis,
slots 5 and 6 in a six- or nine-slot chassis, and slots 7 and 8 in a 13-slot chassis. One Supervisor
serves as the running, or active, Supervisor, and the other serves as the standby Supervisor. The
active Supervisor Engine is the first one to come online. This can be confirmed by the “Active”
Light Emitting Diode (LED) externally on the Supervisor or by entering the show module
command at the console. The active Supervisor processes all administrative and management
functions, such as Simple Network Management Protocol (SNMP), command-line interface
(CLI) console, Telnet, Spanning Tree Protocol (STP), Port Aggregation Protocol (PAgP),
Cisco Discovery Protocol (CDP), Dynamic Trunking Protocol (DTP), and VLAN Trunking
1439_CCNP_3.book Page 343 Wednesday, October 27, 2004 9:54 AM

Implementing Module Redundancy in a Multilayer Switched Network 343

Protocol (VTP) functions. Redundant Supervisor Engines must be of the same type with the
same model feature card. If an active Supervisor is taken offline or fails, the standby Supervi-
sor takes over control of the system.

Figure 6-2 Catalyst Switch Supervisor Engines Manage All Other Modules in the Chassis

The two Supervisor Engines in a redundant configuration have distinct functions. The active
Supervisor is responsible for controlling the system bus and all line cards. All protocols are
running on the active Supervisor, and it performs all packet forwarding. The standby Supervi-
sor does not communicate with the line cards. The standby Supervisor receives packets from
the network and populates its forwarding tables with this information. However, the standby
Supervisor does not participate in any packet forwarding or provide any load sharing. The rel-
evant protocols on the system are initialized, but not active, on the standby Supervisor. The
Catalyst 6500 series Supervisor Engines are hot-swappable. This means that the standby
Supervisor Engine can be installed on an active system without affecting network operation.
The active Supervisor provides all the packet forwarding intelligence for the system. If the
active Supervisor fails, the standby Supervisor maintains the same system load. The standby
Supervisor can be removed and installed without service interruption.
The standby Supervisor polls the active Supervisor on a regular interval using an out-of-band
channel. The active Supervisor Engine might go offline for the following reasons:
■ Hardware failures
■ System overload conditions
■ Memory corruption issues
■ Removal from chassis
■ Operator reset
1439_CCNP_3.book Page 344 Wednesday, October 27, 2004 9:54 AM

344 Chapter 6: Redundancy

The standby Supervisor detects these types of failures and becomes the active Supervisor.
The software on the Supervisor Engine is responsible for restoring the protocols, line cards,
and forwarding engines to normal operation. This restoration takes place using a fast switch-
over or a high-availability switchover.

Implementing Redundant Supervisor Uplink Modules in


Catalyst Switches
Catalyst 5000 family Supervisor Engine IIG uplink ports are modular, as shown in Figure 6-3.
Modularity lets the administrator install the uplink module to deliver current bandwidth
requirements. Modularity also ensures an easy migration path. Available options are as
follows:
■ Four-port autosensing 10/100 Fast Ethernet (RJ-45)
■ Four-port 100BASE-FX (MT-RJ)
■ Two-port autosensing 10/100 Fast Ethernet (RJ-45)
■ Two-port 100BASE-FX (SC)
■ Two-port Gigabit Ethernet SX, LX/LH (SC), or Gigabit Interface Converter (GBIC)
Any Fast Ethernet uplink port can use Fast EtherChannel technology. Fast EtherChannel pro-
vides up to 800 million packets per second (Mpps) of wire-speed, resilient, and scalable
bandwidth for data center and backbone implementations.

Figure 6-3 The Catalyst 5000 Family Supervisor IIG Supports Modular Uplinks
1439_CCNP_3.book Page 345 Wednesday, October 27, 2004 9:54 AM

Implementing Module Redundancy in a Multilayer Switched Network 345

The Catalyst 4006 Supervisor Engine III (shown in Figure 6-4), Catalyst 4500 Supervisor
Engine IV (shown in Figure 6-5), and Catalyst 6500 Supervisor Engine I and II (shown in
Figure 6-6) support 1000BASE-SX, 1000BASE-LX/LH, and 1000BASE-ZX uplinks via
insertion of GBICs into accommodating slots on these devices.

Figure 6-4 The Catalyst 4006 Supervisor Engine III Delivers a 64-Gbps Switching Fabric with
48-Mpps Forwarding Rate in Hardware for Both Layer 2 and Layer 3/4 Traffic

Figure 6-5 The Catalyst 4000/4500 Supervisor Engine IV Delivers Integrated Resiliency and
CEF-Based Layer 2/3/4 Switching at 48 Mpps
1439_CCNP_3.book Page 346 Wednesday, October 27, 2004 9:54 AM

346 Chapter 6: Redundancy

Figure 6-6 The Catalyst 6000 Family Supervisor Engine I Supports the Policy Feature Card
(on the Left) and the Multilayer Switch Feature Card (on the Right)

The Catalyst 6500 Supervisor Engine 720, shown in Figure 6-7, has three physical uplink
ports:
■ Two Gigabit Ethernet Small Formfactor Pluggable (SFP) ports supporting
1000BASE-SX and 1000BASE-LX/LH
■ One 10/100/1000 RJ-45 port
Only two of the three ports can be active at any one point in time.

NOTE Figure 6-7 The Catalyst 6500 Series Supervisor Engine 720 Delivers CEF-Based Forwarding
The Catalyst 6500 sup- at 400 Mpps/720 Gbps
ports 10 Gigabit Ether-
net modules. Up to
eight 10 Gigabit Ether-
net ports can participate
in a single 10 Gigabit
EtherChannel, provid-
ing 160 Gbps of
bandwidth.

Any Gigabit Ethernet uplink port can use Gigabit EtherChannel technology. With additional
Gigabit Ethernet line cards, Gigabit EtherChannel can provide up to 16 Gbps of wire-speed,
resilient, and scalable bandwidth for data center and backbone implementations.
1439_CCNP_3.book Page 347 Wednesday, October 27, 2004 9:54 AM

Implementing Module Redundancy in a Multilayer Switched Network 347

Implementing Redundant Distributed Forwarding Cards in


Catalyst Switches
The distributed forwarding card (DFC) for the Catalyst 6500 series, shown in Figure 6-8,
delivers high-speed distributed services and forwarding for deployment in data center back-
bones and server farm aggregation. The DFC complements the centralized forwarding of
the Catalyst 6500 Supervisor Engine II by distributing the centralized forwarding intelligence
to each DFC-enabled line card module. This capability provides localized forwarding and
service decisions on each line card and accelerates the forwarding performance of the
Catalyst 6500 series.

Figure 6-8 The DFC Is Installed in DFC-Enabled Line-Card Modules That Perform Distributed
Forwarding, Supported by the Catalyst 6500 Supervisor Engine II

The DFC works with the Switch Fabric Module, Supervisor Engine II with Multilayer Switch
Feature Card 2 (MSFC2) and fabric-enabled cards to provide a framework for a distributed
CEF-based forwarding architecture, as shown in Figure 6-9. Although classic line cards can-
not directly participate in distributed forwarding, CEF capabilities can still be used based on
the centralized capabilities offered by Supervisor Engine II.
The Catalyst 6500 DFC-3 is installed in DFC-enabled line-card modules that perform distrib-
uted forwarding supported by the Catalyst 6500 Supervisor Engine 720 as a field upgrade.
When the DFC-3 is installed, modules that are DFC-enabled make forwarding decisions
locally, leaving the Supervisor Engine free to perform routing and management functions.
The DFC-3 replicates Layer 2 and Layer 3 forwarding logic of the Supervisor 720’s Policy
Feature Card 3 (PFC-3) on each DFC-3-equipped line card. This enables hardware accelera-
tion of IPv6, Multiprotocol Label Switching (MPLS), Generic Routing Encapsulation (GRE),
quality of service (QoS), access control list (ACL) policy enforcement, and more. The DFC-
3-equipped interface modules are backward-compatible with all other Catalyst 6500 interface
modules. However, the modules must be used with a Supervisor 720, and any other modules
that will use distributed forwarding must also be DFC-3-equipped.
1439_CCNP_3.book Page 348 Wednesday, October 27, 2004 9:54 AM

348 Chapter 6: Redundancy

Figure 6-9 Local Forwarding Is Provided by the DFC Architecture

Master Routing
FIB Table Table

Adjacency
Table
MSFC

Slave Adjacency Slave Adjacency


FIB Table Table FIB Table Table

ASIC ASIC
Multigigabit
Line Card Crossbar Fabric Line Card

Implementing Redundant Power Supplies


To meet the need for power redundancy, Cisco has added redundant power as an option across a
broad range of devices. Redundant power supplies are appropriate in situations that are con-
sidered mission-critical. In systems with redundant power supplies, both power supplies must
be of the same wattage. The Catalyst 6000 family switches allow mixing of AC-input and
DC-input power supplies in the same chassis.
With redundancy enabled and two power supplies of equal wattage installed, the total power
drawn from both supplies is at no time greater than the capacity of one supply. If one supply
malfunctions, the other supply can take over the entire system load. When two power supplies
of equal wattage are used, as shown in Figure 6-10, each provides approximately half of the
required power to the system. Load sharing and redundancy are enabled automatically. No
software configuration is required.
With redundancy enabled and two power supplies of unequal wattage installed, both power
supplies come online, but a syslog message says that the lower-wattage power supply will be
disabled. If the active power supply fails, the lower-wattage power supply comes online and
modules are powered down, if necessary, to accommodate the lower-wattage power supply.
In a nonredundant configuration, the power available to the system is the combined power
capacity of both power supplies. The system powers up as many modules as the combined
capacity allows. However, if one supply fails and there is not enough power for all previously
powered-up modules, the system powers down some modules. These modules are marked as
power-deny in the show module status field.
1439_CCNP_3.book Page 349 Wednesday, October 27, 2004 9:54 AM

Implementing Router Redundancy in a Switched Network 349

Figure 6-10 Redundant Power Supplies Are Recommended for Any Chassis-Based Catalyst Switch

You can reconfigure the configuration of the power supplies from redundant to nonredundant
at any time. When switching from a redundant to a nonredundant configuration, both power
supplies are enabled even if a lower-wattage power supply is present. When switching from a
nonredundant to a redundant configuration, both power supplies are initially enabled. If they
are of the same wattage, they remain enabled. If the power supplies are of different wattages,
a syslog message appears, and the lower-wattage supply is disabled.

Implementing Router Redundancy in a Switched


Network
An evolution has taken place with respect to technologies enabling router redundancy from
the access and distribution layers. Proxy ARP was one of the first solutions designed to provide
dynamic access to preferred routers on a given LAN. Other solutions over the years have
included Gateway Discovery Protocol (GDP), multiple default gateways, routing protocols
running on workstations, dynamic host configuration protocol (DHCP), Internet Control
Message Protocol (ICMP) Router Discovery Protocol (IRDP), HSRP, VRRP, and GLBP.
Many of these remain viable options. This chapter focuses mostly on HSRP, but the other
options are also described.
1439_CCNP_3.book Page 350 Wednesday, October 27, 2004 9:54 AM

350 Chapter 6: Redundancy

Router Redundancy Operation


IP routing redundancy is a key component of high-availability strategy for any network,
because it is a critical component of delivering reliable data, voice, and video integration. The
goal of IP routing redundancy is to protect against first-hop router failure when a source host
is unable to dynamically learn the IP address of an alternate first-hop router.
Some options for redundant access to routers include the following:
■ Proxy Address Resolution Protocol (ARP)
■ Multiple default gateways
■ Dynamic routing protocols running on workstations
■ DHCP
Each of these options permits a host some flexibility with respect to where traffic originating
from the host exits on the local LAN segment. The focus at this point is providing redundancy
to hosts, rather than to network devices, such as switches or routers.

Proxy Address Resolution Protocol


Some IP hosts use proxy ARP to select a router. When a host runs proxy ARP, an ARP
request is sent with the IP address of the remote host. A router on the network replies on
behalf of the remote host and provides its own MAC address. With proxy ARP, the host
assumes it is connected to the same segment of the network as the remote host. If Router A
fails, the host continues sending packets to Router A’s MAC address. Those packets are lost
until the host ARP table is updated by way of a new ARP request acquiring the MAC address
of another router on the local segment. It is possible that for a significant period of time the
host will be unable to communicate with the remote host, even though the routing protocol
has converged, and Router B is prepared to transfer packets that would otherwise go through
Router A.

Default Gateways
Specifying a default gateway on a host allows the workstation to simply send the packet to
the default gateway. Some operating systems might have only one default gateway specified.
When this gateway fails, as shown in Figure 6-11, the workstation cannot reach remote
subnets.
Although the network infrastructure can quickly recover and reconverge, the host does not
know about a new default gateway. With operating systems that support multiple default gate-
way entries, such as Microsoft Windows, failover between the entries is not dynamic. The
operating system sends an echo to each gateway entry in order on bootup. The first gateway
to reply is used as the default gateway. Using another listed gateway, in the event of a router
failure, requires a restart of the host.
1439_CCNP_3.book Page 351 Wednesday, October 27, 2004 9:54 AM

Implementing Router Redundancy in a Switched Network 351

Figure 6-11 A Single Static Default Gateway on Hosts Does Not Provide an Adequate Failover
Mechanism

I need to get to
File Server A, but
my default gateway
is down.

I can route
packets to File
Server A.

Router 1 Router 2
172.16.10.82 172.16.10.169
0010.f6b3.d000 0010.0b79.5800

Subnet A Subnet B
172.16.50.0 172.16.51.0

Core
File Server A

Dynamic Routing Protocol


Some IP hosts run a dynamic routing protocol, such as Routing Information Protocol (RIP) or
Open Shortest Path First (OSPF), to discover routes. Running a dynamic routing protocol on
every host might not be feasible for numerous reasons:
■ Administrative and processing overhead
■ Security issues
■ Lack of a protocol implementation for some platforms

Dynamic Host Configuration Protocol


DHCP provides a mechanism for passing IP configuration information to hosts on a TCP/IP
network. A host joining the network requests IP configuration information from the DHCP
server. The configuration information typically consists of an IP address and a default gateway.

Interactive Media Activity Point and Click: Router Redundancy Operation


After completing this activity, you will understand basic router redundancy operation.
1439_CCNP_3.book Page 352 Wednesday, October 27, 2004 9:54 AM

352 Chapter 6: Redundancy

ICMP Router Discovery Protocol (IRDP)


Some newer IP hosts use ICMP Router Discovery Protocol (IRDP), defined in RFC 1256, to
find a new router when a route becomes unavailable. A host that uses IRDP listens for hello
multicast messages from the router that the host is configured to use. The host switches to an
alternate router when it no longer receives those hello messages. IRDP has a default adver-
tisement rate of once every 7 to 10 minutes. The default lifetime is 30 minutes. These default
timer values mean that IRDP is not suitable to detect first-hop failures.

Enabling IRDP Processing


The only required task for configuring IRDP routing on a specified interface is to enable
IRDP processing on an interface. Use the command ip irdp in interface configuration mode.
When enabling IRDP processing, the default parameters apply. When enabled, IRDP uses the
following defaults:
■ Broadcast IRDP advertisements
■ Maximum interval between advertisements—600 seconds
■ Minimum interval between advertisements—450 seconds
■ Preference—0
To display IRDP values, use the command show ip irdp.

Troubleshooting IRDP
Use the debug ip icmp command to display information on ICMP transactions. This com-
mand helps determine whether the router is sending or receiving ICMP messages. Use this
command when troubleshooting an end-to-end connection problem. The no form of this com-
mand disables debugging output.

Hot Standby Router Protocol (HSRP)


One way to achieve near-100-percent network uptime is to use Hot Standby Router Protocol
(HSRP) (see RFC 2281). HSRP provides network redundancy for IP networks, ensuring that
user traffic immediately and transparently recovers from first-hop failures in network edge
devices or access circuits.
By sharing an IP address and a MAC address, a set of two or more routers can operate as a
single router called a virtual router. This set of routers is known as an HSRP group or a
standby group. A single router elected from the group is responsible for forwarding the
packets that hosts send to the virtual router. To minimize network traffic, only the active and
standby routers send periodic HSRP messages as soon as the protocol has completed the elec-
tion process. If the local segment has only two routers, one is the active router and one is the
1439_CCNP_3.book Page 353 Wednesday, October 27, 2004 9:54 AM

Implementing Router Redundancy in a Switched Network 353

standby router, as shown in Figures 6-12 and 6-13. If the active router fails, the standby router
takes over as the active router, as shown in Figures 6-14 and 6-15. If the standby router fails
or becomes the active router, another router is elected as the standby router. Hosts continue to
forward IP packets to a consistent IP and virtual MAC address. The changeover between
routes is transparent to the end workstation.

Figure 6-12 In a Stable Network, an Active Router Forwards All Traffic for an HSRP Group

Active Standby
.4 .3
10.88.1.1
GW.1
10.88.1.0/24

.7 .5 .6

GW.1 GW.1 GW.1

Figure 6-13 The Active Router Is Assigned the Virtual MAC Address

VIP: 10.88.1.1 VIP: 10.88.1.1


MAC: 0000.0c12.3456 MAC: 0000.0c78.9abc
VMAC: 0000.0c07.ac00

Active Standby
.4 .3
10.88.1.1 zzzzzz
GW.1 (Snore)
10.88.1.0/24

.7 .5 .6

GW.1 GW.1 GW.1

VIP = Virtual IP Address


VMAC = Virtual MAC Address
1439_CCNP_3.book Page 354 Wednesday, October 27, 2004 9:54 AM

354 Chapter 6: Redundancy

Figure 6-14 When the Active Router Goes Down, the Standby Router Immediately Takes Over

VIP: 10.88.1.1 VIP: 10.88.1.1


MAC: 0000.0c12.3456 MAC: 0000.0c78.9abc
VMAC: 0000.0c07.ac00

Active
.4 .3
10.88.1.1
GW.1
10.88.1.0/24

.7 .5 .6

GW.1 GW.1 GW.1

Figure 6-15 The New Active Router Is Assigned the Virtual MAC Address

VIP: 10.88.1.1
VIP: 10.88.1.1
MAC: 0000.0c78.9abc
MAC: 0000.0c12.3456
VMAC: 0000.0c07.ac00

Standby Active
.4 .3
zzzzzz 10.88.1.1
(Snore) GW.1
10.88.1.0/24

.7 .5 .6

GW.1 GW.1 GW.1

On a particular LAN, multiple hot standby groups might coexist and overlap. Each standby
group emulates a single virtual router. The individual routers might participate in multiple
groups. In this case, the router maintains separate states and timers for each group. Each
standby group has a single virtual MAC and IP address.
The HSRP MAC address is derived from the HSRP group number. The HSRP MAC address
has the form 0000.0c07.acxx, where xx is the HSRP group number.
1439_CCNP_3.book Page 355 Wednesday, October 27, 2004 9:54 AM

Implementing Router Redundancy in a Switched Network 355

Virtual Router Redundancy Protocol (VRRP)


Virtual Router Redundancy Protocol (VRRP) is an Internet Engineering Task Force (IETF)
proposed standard (see RFC 2338) that is nearly identical to the Cisco-proprietary HSRP. As
a standards-based solution introduced in 1998, VRRP is now being made available to provide
interoperability using equipment from multiple vendors.
IP routing redundancy is designed to allow for transparent failover at the first-hop router.
Both HSRP and VRRP allow two or more devices to work together in a group, sharing a
single virtual IP address. The virtual IP address is configured in each end-user workstation
as a default gateway address and is cached in the host ARP cache.
In an HSRP or VRRP group, one router is elected to handle all requests sent to the virtual IP
address. An HSRP group has an active router, a standby router, and perhaps many listening
routers. A VRRP group has one master router and one or more backup routers, as shown in
Figure 6-16.

Figure 6-16 VRRP Uses a Master Router and Backup Routers, Similar to HSRP Active and
Standby Routers

VRRP Active VRRP Backup VRRP Backup


IP: 10.0.0.254 IP: 10.0.0.253 IP: 10.0.0.252
MAC: 0000.0c12.3456 MAC: 0000.0c78.9abc MAC: 0000.0cde.f123
vIP: 10.0.0.10 vIP: vIP:
vMAC: 00000.0c07.ac00 vMAC: vMAC:

Gateway Routers
R1 R2 R3

Clients

IP: 10.0.0.1 IP: 10.0.0.2 IP: 10.0.0.3


MAC: aaaa.aaaa.aa01 MAC: aaaa.aaaa.aa02 MAC: aaaa.aaaa.aa03
GW: 10.0.0.10 GW: 10.0.0.10 GW: 10.0.0.10
ARP: 0000.0c07.ac00 ARP: 0000.0c07.ac00 ARP: 0000.0c07.ac00

When a group initializes, messages are exchanged to elect the active or master router. Within
these messages, information, such as group identifier, priority, virtual IP address, and hello
advertisement interval, is exchanged. The routers in a group continue to exchange these mes-
sages at a configured interval. In HSRP, both the active and standby routers send periodic
hello messages. In VRRP, only the master sends periodic messages, called advertisements.
1439_CCNP_3.book Page 356 Wednesday, October 27, 2004 9:54 AM

356 Chapter 6: Redundancy

Using the information in these messages, a standby or backup router can determine whether it
needs to take over the active or master role in a group. If a hello message is not received from
the active or master router in the defined interval, the standby or backup router automatically
assumes the role of active or master. When the original active or master router becomes
available again, it sends out a hello or advertisement message and regains the lead IP packet-
forwarding role within the group. All this is transparent to the end user traversing this first-hop
group. Connectivity is maintained with little or no loss of traffic and functionality.
Cisco recommends using HSRP, because it is a proven technology that has superior conver-
gence characteristics. Use VRRP only when local subnet interoperability is required with
equipment from another vendor.
VRRP is supported on Cisco 2600XM, 3600, and 3700 routers running Cisco IOS software
Release 12.2T or later.

Troubleshooting VRRP
Customizing the behavior of VRRP is optional. As soon as a VRRP group is enabled, that
group is operating. Always customize VRRP before enabling it. Otherwise, a router could
become the master virtual router before the customization is complete.

Gateway Load Balancing Protocol (GLBP)


Like HSRP and VRRP, Gateway Load Balancing Protocol (GLBP) provides nonstop path
redundancy for IP by sharing protocol and MAC addresses between redundant gateways. GLBP
also allows a group of routers to share the load of the default gateway on a LAN. This load
sharing improves performance by facilitating better use of network resources when multiple
upstream paths are available and increases reliability and network availability by removing
the single point of failure—the first-hop router. GLBP allows a router to automatically
assume the forwarding function of another router in the group if a failure occurs in any other
gateway router. The various GLBP components and concepts are defined as follows:
■ Active Virtual Gateway (AVG)—One virtual gateway within a particular GLBP group
is elected the AVG. The AVG is responsible for the operation of protocol, such as allo-
cating MAC addresses.
■ Virtual Forwarder (VF)—An abstract entity within a GLBP gateway that might
assume responsibility for a virtual MAC address.
■ Active Virtual Forwarder (AVF)—One VF within a particular GLBP group is elected
the AVF. The AVF is responsible for forwarding packets sent to a particular virtual
MAC address.
1439_CCNP_3.book Page 357 Wednesday, October 27, 2004 9:54 AM

Implementing Router Redundancy in a Switched Network 357

■ Primary Virtual Forwarder (PVF)—A PVF is a VF that has been assigned the virtual
MAC address by the AVG.
■ Secondary Virtual Forwarder (SVF)—An SVF is a VF that has learned the virtual
MAC address from a hello message.
Cisco generally recommends the use of GLBP in place of HSRP when more than two routers
reside on a single LAN segment because of its built-in load-balancing feature. GLBP performs
a similar, but not identical, function for the user as the HSRP and the VRRP. HSRP and
VRRP allow multiple routers to participate in a virtual router group configured with a virtual
IP address. One member is elected as the active router to forward packets sent to the virtual IP
address for the group. The other routers in the group are redundant until the active router
fails. These standby routers have unused bandwidth that the protocol is not using. Although
multiple virtual router groups can be configured for the same set of routers, the hosts must be
configured for different default gateways, which results in an extra administrative burden.
GLBP provides load balancing over multiple routers (gateways) using a single virtual IP
address and multiple virtual MAC addresses. Each host is configured with the same virtual
IP address, and all routers in the virtual router group participate in forwarding packets.
Figures 6-17 to 6-20 illustrate the operation of GLBP.
GLBP is supported on the following Cisco hardware platforms, with Cisco IOS software
Release 12.2(15)T or later:
■ 1700 series routers
■ 2600 series routers
■ 3620 routers
■ 3631 routers
■ 3640 routers
■ 3660 routers
■ 3725 routers
■ 3745 routers
■ 7100 series routers
■ 7200 series routers
■ 7400 series routers
■ 7500 series routers
■ Catalyst 6000 MSFC
■ Catalyst 6500 Supervisor Engine 720
1439_CCNP_3.book Page 358 Wednesday, October 27, 2004 9:54 AM

358 Chapter 6: Redundancy

Figure 6-17 GLBP Lets Distinct Hosts Receive Distinct ARP Replies, with Distinct MAC Addresses
Associated with the Same Virtual IP Address

1 2
AVG/AVF AVF
vIP
10.88.1.10

glbp 1 ip 10.88.1.10 glbp 1 ip 10.88.1.10


vMAC 0000.0000.0001 vMAC 0000.0000.0002
R1 R2
.1 .2

ARP Reply
10.88.1.0/24

.4 .5

A B

ARPs for 10.88.1.10 ARPs for 10.88.1.10


Gets MAC 0000.0000.0001 Gets MAC 0000.0000.00002

Figure 6-18 Distinct MAC Addresses Associated with the Same Virtual IP Address Permit
Load Balancing

1 2
AVG/AVF AVF
vIP
10.88.1.10

glbp 1 ip 10.88.1.10 glbp 1 ip 10.88.1.10


vMAC 0000.0000.0001 vMAC 0000.0000.0002
R1 R2
.1 .2

10.88.1.0/24

.4 .5

A B

ARPs for 10.88.1.10 ARPs for 10.88.1.10


Gets MAC 0000.0000.0001 Gets MAC 0000.0000.00002
1439_CCNP_3.book Page 359 Wednesday, October 27, 2004 9:54 AM

Implementing Router Redundancy in a Switched Network 359

Figure 6-19 GLBP Has a Failover Mechanism, Just as VRRP and HSRP Do

1 2
AVG/AVF AVF
vIP
10.88.1.10

glbp 1 ip 10.88.1.10 glbp 1 ip 10.88.1.10


vMAC 0000.0000.0001 vMAC 0000.0000.0002
R1 R2
.1 .2

10.88.1.0/24

.4 .5

A B

ARPs for 10.88.1.10 ARPs for 10.88.1.10


Gets MAC 0000.0000.0001 Gets MAC 0000.0000.00002

Figure 6-20 During Failover, GLBP Shifts the Role of the Virtual MAC Address Used by One Host
and Associated with the Virtual IP

1 2
AVG/AVF AVF
vIP
10.88.1.10
glbp 1 ip 10.88.1.10
glbp 1 ip 10.88.1.10 vMAC 0000.0000.0002
R1 R2 vMAC 0000.0000.0001
.1 .2

10.88.1.0/24

.4 .5

A B

ARPs for 10.88.1.10 ARPs for 10.88.1.10


Gets MAC 0000.0000.0001 Gets MAC 0000.0000.00002
1439_CCNP_3.book Page 360 Wednesday, October 27, 2004 9:54 AM

360 Chapter 6: Redundancy

Troubleshooting GLBP
GLBP allows traffic from a single common subnet to go through multiple redundant gateways
while using a single virtual IP address. GLBP provides the same level of first-hop failure
recovery capability as that provided by HSRP and VRRP.
Cisco IOS software contains show and debug commands to allow network operators to deter-
mine the status of GLBP. These commands are useful for verifying the operation of GLBP
and verifying that the design goals are being met relative to tracked objects and forwarder
states.
Use the show glbp command to display GLBP operational information and statistics.
To display debugging messages about GLBP conditions, use the debug condition glbp
command.

Single Router Mode (SRM) Redundancy


Single Router Mode (SRM) redundancy provides an alternative to having both MSFCs in a
chassis active at the same time.
The designated MSFC is the MSFC that comes up first or has been up the longest. The desig-
nated MSFC can be the MSFC in slot 1 or the MSFC in slot 2. There is no mechanism to
decide which MSFC is the designated one; the first to come online is the designated MSFC.
Figure 6-21 shows two Catalyst 6500 switches, each with redundant MSFCs.

Figure 6-21 Single Router Mode Is the Preferred Redundancy Mechanism to Use with Dual MSFCs
in a 6500 Chassis

AS 10 AS 20

192.168.1.2/24 VLAN 10 VLAN 20 192.168.2.2/24

AS 4

Port 3/2 Port 3/3

Trunk

Port 5/2 Port 4/2


int vlan10: 192.168.1.1/24 int vlan10: 192.168.1.3/24
int vlan20: 192.168.2.3/24 int vlan20: 192.168.2.1/24

CAT 1 CAT 2
Slot 1: Sup 1/MSFC 1 Slot 1: Sup 1/MSFC 1
Slot 2: Sup 2/MSFC 2 Slot 2: Sup 2/MSFC 2
1439_CCNP_3.book Page 361 Wednesday, October 27, 2004 9:54 AM

Implementing Router Redundancy in a Switched Network 361

Using SRM redundancy, only the designated MSFC is visible to the network at any given
time. The nondesignated MSFC is booted up completely and participates in configuration
synchronization, which is automatically enabled when entering SRM. The configuration of
the nondesignated MSFC is exactly the same as the designated MSFC, but its interfaces are
kept in a “line down” state and are not visible to the network. Processes, such as routing pro-
tocols, are created on the nondesignated MSFC and the designated MSFC. All nondesignated
MSFC interfaces are in a “line down” state and do not send updates to or receive updates
from the network.
When the designated MSFC fails, the nondesignated MSFC changes its state to become the
designated MSFC, and the interface states change to “link up.” The MSFC builds its routing
table while the existing Supervisor Engine switch processor entries are used to forward Layer 3
traffic. After the newly designated MSFC builds its routing table, the entries in the switch
processor are updated.
SRM is Cisco’s recommended method of internal MSFC redundancy.

Server Load Balancing (SLB)


Server Load Balancing (SLB) is an IOS-based solution defining a virtual server that repre-
sents a group of real servers in a server farm, as shown in Figure 6-22.

Figure 6-22 SLB Permits Server Redundancy by Way of a Virtual Server

Web Servers

Internet

IOS SLB 2

This environment connects clients to the IP address of a single virtual server. The virtual
server IP address, as shown in Figure 6-23, is configured as a loopback address, or a second-
ary IP address, on each of the real servers.
1439_CCNP_3.book Page 362 Wednesday, October 27, 2004 9:54 AM

362 Chapter 6: Redundancy

Figure 6-23 SLB Relies on a Virtual Server with a Virtual IP Address

Real Addresses

Virtual Address 192.168.1.1 – 80


192.168.1.200 192.168.1.1 – 20

192.168.1.2 – 80

When a client initiates a connection to the virtual server, the SLB function chooses a real
server for the connection based on a load-balancing algorithm. The network gains scalability
and availability when virtual servers represent server farms. The addition of new servers and
the removal or failure of existing servers can occur at any time without affecting the availabil-
ity of the virtual server.
SLB is supported on the following platforms:
■ Catalyst G-L3 series
■ Catalyst 6000 series
■ Cisco 7200 series
■ Cisco 7400 series
■ Cisco 10000 series

Troubleshooting SLB
To obtain and display runtime information when monitoring and maintaining IOS SLB, use
the following commands in EXEC mode:
■ show ip slb conns [vserver virtserver-name] [client ip-address] [detail]—Displays all
connections handled by IOS SLB or, optionally, only those connections associated with
a particular virtual server or client.
■ show ip slb dfp [agent ip_addr port] [detail] [weights]—Displays information about
Dynamic Feedback Protocol (DFP) and DFP agents and about the weights assigned to
real servers.
■ show ip slb reals [vserver virtserver-name] [detail]—Displays information about the
real servers defined to IOS SLB.
■ show ip slb serverfarms [name serverfarm-name] [detail]—Displays information
about the server farms defined to IOS SLB.
1439_CCNP_3.book Page 363 Wednesday, October 27, 2004 9:54 AM

HSRP Operations 363

■ show ip slb stats—Displays IOS SLB statistics.


■ show ip slb sticky [client ip-address]—Displays information about the sticky connec-
tions defined to IOS SLB.
■ show ip slb vservers [name virtserver-name] [detail]—Displays information about
the virtual servers defined to IOS SLB.
The debug commands related to the IOS SLB feature are as follows:
■ all—Displays all debug messages for IOS SLB.
■ conns—Displays debug messages for all connections being handled by IOS SLB,
including Wireless Session Protocol (WSP) events and states.
■ dfp—Displays debug messages for Dynamic Feedback Protocol (DFP). To display
debug messages for the DFP agent subsystem, use debug ip dfp agent.
■ firewallfarm—Displays debug messages related to firewall load balancing.
■ icmp—Displays all ICMP debug messages for IOS SLB.
■ natpool—Displays debug messages related to the IOS SLB client NAT pool.
■ probe—Displays debug messages related to probes.
■ reals—Displays debug messages for all real servers defined to IOS SLB.
■ replication—Displays debug messages related to IOS SLB stateful backup virtual
servers.
■ sessions—Displays debug messages for all sessions being handled by IOS SLB.
■ vservers—Displays debug messages for all virtual servers defined to IOS SLB.
Having taken a brief tour of VRRP, GLBP, SRM, and SLB, we now return the focus to HSRP.
The operation, configuration, and monitoring of HSRP are discussed. The detailed descrip-
tions of VRRP, GLBP, SRM, and SLB operation, configuration, and monitoring are beyond
the scope of this book and course.

HSRP Operations
The main components of HSRP are an active router, a standby router, and a virtual router.
In Figure 6-24, the active router forwards data packets and transmits hello messages. The
standby router monitors the active router’s status and quickly begins forwarding packets if the
active router fails. The standby router also transmits hello messages to other routers in the
HSRP group. The virtual router doesn’t really exist. It simply represents a consistently avail-
able router with an IP address and MAC address to the hosts on a network.
1439_CCNP_3.book Page 364 Wednesday, October 27, 2004 9:54 AM

364 Chapter 6: Redundancy

Figure 6-24 HSRP Standby Groups Consist of Multiple Routers Performing Specific Roles

HSRP Group
Standby Virtual Active
Router Router Router

It is possible that several other routers exist in an HSRP standby group. These other routers
monitor HSRP hello messages, but do not respond. They function as normal routers that for-
ward packets sent to them but do not forward packets addressed to the virtual router. These
additional HSRP routers remain in init state.
How does the standby router know when the active router fails? The standby router stops
receiving hello messages from the active router and takes on the role of the active router.
Because the hosts are using a virtual IP and MAC address, the hosts see minimal or no
service disruption.
If both the active and standby routers fail, all other routers in the group contend for the active
and standby roles. The router with the lowest MAC address becomes the active router unless
an HSRP priority is configured.
To facilitate load sharing, a single router might be a member of multiple HSRP standby
groups on a single segment. Each standby group emulates a single virtual router. A LAN can
have up to 255 standby groups. Multiple HSRP groups are also supported on VLAN, port-
channel, and Bridge Group Virtual Interface (BVI) interfaces.
In Figure 6-25, both Router A and Router B are members of Groups 1 and 2. Router A is the
active forwarding router for Group 1 and the standby router for Group 2. Router B is the
active forwarding router for Group 2 and the standby router for Group 1.
Routers also can simultaneously provide redundant backup and perform load sharing across
different IP subnets, as shown in Figure 6-26.
1439_CCNP_3.book Page 365 Wednesday, October 27, 2004 9:54 AM

HSRP Operations 365

Figure 6-25 Routers Can Belong to Multiple Groups on the Same Subnet in a VLAN

Active Router for Group 1


Standby Router for Group 2
Virtual
Router Group 2

Network A
172.16.10.0 VLAN 10

B
Group 1 Virtual
Router B
Router

Standby Router for Group 1


Active Router for Group 2

Figure 6-26 Routers Can Belong to Multiple Groups in Multiple VLANs

Group 1 Group 2

Virtual Virtual
Router Router
VLAN 10
Network
172.16.10.0

Network
172.16.20.0

Virtual Virtual VLAN 20


Router Router

Group 3 Group 4

This is possible because for each standby group, an IP address and a single, well-known
MAC address with a unique group identifier are allocated to the group.
1439_CCNP_3.book Page 366 Wednesday, October 27, 2004 9:54 AM

366 Chapter 6: Redundancy

A group’s IP address is in the range of addresses belonging to the subnet in use on the LAN.
However, the group’s IP address must differ from the addresses allocated as interface
addresses on all routers and hosts on the LAN, including virtual IP addresses assigned to
other HSRP groups.
Initially, the standby group has no active router. Within the standby group, the router with the
highest standby priority becomes the active router. The default priority for an HSRP router is
100, which can be configured. The active router responds to traffic for the virtual router. If an
end station sends a packet to the virtual router MAC address, the active router receives and
processes that packet. If an end station sends an ARP request with the virtual router IP
address, the active router replies with the virtual router MAC address.
In Figure 6-27, Router A has a priority of 200 and Router B has a default priority of 100.
Router A assumes the active router role and forwards all frames addressed to the well-known
MAC address of 0000.0c07.acxx, where xx is the HSRP group identifier. In Figure 6-27, the
HSRP group number is 0x0a or 10. The well-known MAC address of 0000.0c07.acxx is used
for all HSRP configurations, unless HSRP is configured to use a different MAC address.

Figure 6-27 The Router with the Highest HSRP Priority Becomes the Active Router. The Active
Router Responds to ARP Requests with the MAC Address of the Virtual Router.

I Need To Get To
172.16.3.127

Use MAC Address


0000.0c07.ac0a
Router A Virtual Router Router B
172.16.10.110
Priority 200 Priority 100
172.16.10.82 172.16.10.169
0010.f6b3.d000 0010.0b79.5800

Virtual 0000.0c07.ac0a Virtual


Router Router

File Server A
Core 172.16.3.127

The Virtual Router MAC Address


In Figure 6-28, the MAC address used by the virtual router is made up of the following three
components:
■ Vendor ID—The first 3 bytes of the MAC address.
■ HSRP code—2 bytes (always 07.ac) indicating that the MAC address is for an HSRP
virtual router.
■ Group ID—The last byte of the MAC address.
1439_CCNP_3.book Page 367 Wednesday, October 27, 2004 9:54 AM

HSRP Operations 367

Figure 6-28 The HSRP Well-Known Virtual MAC Address Is Crucial to HSRP Operation

HSRP Group 10
Router#show ip arp
172.16.10.82 172.16.10.169

172.16.10.110

Protocol Address Age (min) Hardware Addr Type Interface


Internet 172.16.10.82 - 0010.f6b3.d000 ARPA vlan10
Internet 172.16.10.169 - 0010.0b79.5800 ARPA vlan10
Internet 172.16.10.110 0010.0c07.ac0a ARPA vlan10

Vendor Code HSRP Group Number


HSRP Well-Known
Virtual MAC Address

To display the virtual IP and MAC address, use the command show standby in privileged
EXEC mode, as shown in Example 6-1.

Example 6-1 The show standby Command Is Very Useful in Monitoring HSRP and Verifying HSRP Operation

Router#show standby
FastEthernet0/0 - Group 0
Local state is Active, priority 100
Hellotime 3 holdtime 10
Next hello sent in 00:00:00.630
Hot standby IP address is 10.1.1.1 configured
Active router is local
Standby router is 10.1.1.3 expires in 00:00:09
Standby virtual mac address is 0000.0c07.ac00
FastEthernet0/1 - Group 0
Local state is Standby, priority 100
Hellotime 3 holdtime 10
Next hello sent in 00:00:01.542
Hot standby IP address is 10.1.3.1 configured
Active router is 10.1.2.3 expires in 00:00:08
Standby router is local
Standby virtual mac address is 0000.0c07.ac00
1439_CCNP_3.book Page 368 Wednesday, October 27, 2004 9:54 AM

368 Chapter 6: Redundancy

HSRP Messages
All routers in a standby group send or receive HSRP messages. These messages are used to
determine and maintain the router roles within the group. HSRP messages are encapsulated
in the data portion of User Datagram Protocol (UDP) packets (see Figure 6-29) and use port
number 1985. HSRP messages use the interface IP address, not the virtual IP address, as the
source IP address. The HSRP messages are sent to the destination multicast address (224.0.0.2).
This is the multicast address used to communicate with all routers. The Time-To-Live (TTL)
on the packet is set to 1.

Figure 6-29 HSRP Messages Use the Data Portion of the UDP Segment

1 Octet 1 Octet 1 Octet 1 Octet


Version Op Code State Hello Time
Holdtime Priority Group Reserved
Authentication Data
Authentication Data
Virtual IP Address

The HSRP message fields are as follows:


■ Version—Indicates the version of HSRP.
■ Op Code—Describes the type of message contained in this packet:
— Hello = 0 Messages are sent to indicate that a router is running and can become
either the active or standby router.
— Coup = 1 Messages are sent when a router wants to become the active router.
— Resign = 2 Messages are sent when a router no longer wants to be the active
router.
■ State—Describes the current state (active, standby, init) of the router sending the
message.
■ Hellotime—Meaningful only in hello messages. This field stores the approximate
period, in seconds, between the hello messages that the router sends.
■ Holdtime—Meaningful only in hello messages. This field stores the amount of time
that the current hello message should be valid. The time is given in seconds.
■ Priority—Used to elect the active and standby routers. When the priorities of two dif-
ferent routers are compared, the router with the numerically higher priority wins. In the
case of routers with equal priority, the router with the higher IP address wins.
■ Group—Identifies the standby group. Values of 0 to 255 are valid.
■ Reserved—An 8-bit field reserved for future use.
1439_CCNP_3.book Page 369 Wednesday, October 27, 2004 9:54 AM

HSRP Configuration 369

■ Authentication Data—Contains a clear-text eight-character reused password.


■ Virtual IP Address—Contains the IP address of the virtual router used by this group.
Internally, each router in the standby group implements a state machine. Only the active and
standby routers send periodic HSRP messages after the protocol has completed the election
process.

HSRP States
HSRP defines six HSRP states in which an HSRP-enabled router can exist:
■ Initial—The state from which the routers begin the HSRP process. This state indicates
that HSRP is not running. It is entered via a configuration change or when an interface
first comes up.
■ Learn—The router has not determined the virtual IP address and has not yet seen an
authenticated hello message from the active router. In this state, the router is still wait-
ing to hear from the active router.
■ Listen—The router knows the virtual IP address but is neither the active router nor the
standby router. It listens for hello messages from those routers. Routers other than the
active and standby router remain in the listen state.
■ Speak—The router sends periodic hello messages and actively participates in the elec-
tion of the active or standby router. A router cannot enter Speak state unless it has the
virtual IP address.
■ Standby—The router is a candidate to become the next active router and sends peri-
odic hello messages. Excluding transient conditions, there must be at most one router
in the group in Standby state.
■ Active—The router is currently forwarding packets that are sent to the group virtual
MAC address. The router sends periodic hello messages. Excluding transient condi-
tions, there must be at most one router in Active state in the HSRP group.

Interactive Media Activity Drag and Drop: HSRP States


After completing this activity, you will have a basic understanding of HSRP states.

HSRP Configuration
To configure a router as a member of an HSRP standby group, enter the following interface
configuration command:
standby group-number ip virtual-ip-address
1439_CCNP_3.book Page 370 Wednesday, October 27, 2004 9:54 AM

370 Chapter 6: Redundancy

■ group-number—Optional. The HSRP group to which this interface belongs. Specifying


a unique group number in the standby command lets you create multiple HSRP
groups. The default group is 0.
■ virtual-ip-address—The IP address of the virtual HSRP router.
In Cisco IOS software Release 12.1.3.T and later, HSRP has been changed to support ICMP
redirect. Prior versions of IOS require disabling of ICMP redirects. While running HSRP, it is
important that the end-user stations cannot discover the actual MAC addresses of the routers
as the destination MAC for the default gateway. Any protocol that tells a host the router’s
actual address must be disabled. To ensure that the actual addresses of the participating HSRP
routers are not discovered, enabling HSRP on a Cisco router interface automatically disables
ICMP redirects on that interface.
The standby ip command changes the interface to the appropriate state. Figure 6-30 shows
an example of the state message, automatically generated upon successful enabling of HSRP.

Figure 6-30 Console Messages Indicate HSRP State Changes

Backbone HSRP Group 50

FastEthernet 0/1 Virtual Router FastEthernet 0/1

A B
FastEthernet 0/0 10.1.1.1 FastEthernet 0/0
10.1.1.2 10.1.1.3

IP Address: 10.1.1.50
Default Gateway 10.1.1.1

1w0d: %STANDBY-6-STATECHANGE: Standby: 50:


FastEthernet0/0 state
Speak -> Standby
1w0d: %STANDBY-6-STATECHANGE: Standby: 50:
FastEthernet0/0 state
Standby -> Active

Output from the show running-config command shows the following:


■ Interface FastEthernet 0/0 is a member of HSRP standby Group 50.
■ The virtual router IP address is 10.1.1.1.
■ ICMP redirects are disabled.
1439_CCNP_3.book Page 371 Wednesday, October 27, 2004 9:54 AM

HSRP Configuration 371

To remove an interface from an HSRP group, enter the no standby group ip command.

How HSRP Addresses Redundancy Issues


HSRP provides a way for end nodes to keep communicating between networks even if indi-
vidual local routers become unavailable. HSRP routers on a LAN segment or VLAN commu-
nicate among themselves to designate three possible router states:
■ Active
■ Standby
■ Init
If an end node sends a packet to the virtual MAC address, the active router receives that
packet and processes it. If an end node sends an ARP request, the active router replies with
the virtual MAC address. The routers participating in HSRP can be configured to respond
with their burned-in MAC address (BIA) instead of a virtual MAC address.
In Figure 6-31, Anderson is configured to use the virtual router as the default. Only the virtual
router appears in the Anderson configuration. Broadway is not listed. Upon booting, the routers
might elect Broadway as the active router so that Broadway will deliver packets from Anderson.
If Broadway or its LAN interface goes offline, Central Park takes over as the active router,
continuing with the delivery of Anderson packets. The changes taking place in the network
remain transparent to Anderson. If a third HSRP router is added to the LAN segment, this
router begins acting as the new standby router but remains in init state.

Figure 6-31 Only the IP Address of the Virtual Router Appears on the Anderson TCP/IP
Configuration

Broadway

To ISP

HSRP Router

Anderson

To ISP
Central Park

HSRP also works for proxy ARP. When an active HSRP router receives an ARP request for a
node that is not on the local LAN, it replies with the virtual MAC address. If the router that
originally sent the ARP reply later loses its connection, the new active router can still deliver
1439_CCNP_3.book Page 372 Wednesday, October 27, 2004 9:54 AM

372 Chapter 6: Redundancy

the traffic. Although HSRP works with proxy ARP configurations, it is not a recommended
configuration for administrative and security reasons.

HSRP Standby Priority


Each standby group has its own active and standby routers. The network administrator can
assign a priority value to each router in a standby group. This lets the administrator control
the order in which active routers for that group are selected. To set a router’s priority value,
enter the following command in interface configuration mode:
standby group-number priority priority-value

■ group-number—Optional. The HSRP standby group. The range is 0 to 255.


■ priority-value—The number that prioritizes a potential hot standby router. The range
is 0 to 255. The default is 100.
The router in an HSRP group with the highest priority becomes the forwarding router. The
tiebreaker for matching priorities is the higher IP address.
Figure 6-32 shows that Router A FastEthernet 0/0 has a priority value of 150 in HSRP
standby Group 50.

Figure 6-32 The Priority Value Determines the Active HSRP Router for an HSRP Group

Backbone HSRP Group 50

FastEthernet 0/1 Virtual Router FastEthernet 0/1

A B
FastEthernet 0/0 10.1.1.1 FastEthernet 0/0
10.1.1.2 10.1.1.3

IP Address: 10.1.1.50
Default Gateway 10.1.1.1

A (config-if) #standby 50 priority 150


1439_CCNP_3.book Page 373 Wednesday, October 27, 2004 9:54 AM

HSRP Configuration 373

HSRP Standby Preempt


The standby router assumes the active router role when the active router fails or is removed
from service. This new active router remains as the forwarding router even when the former
active router with the higher priority regains service in the network.
The former active router can be configured to resume the forwarding router role from a router
with a lower priority. To make a router resume the forwarding router role, enter the command
standby group-number preempt in interface configuration mode.
When the standby preempt command is issued, the interface changes to the appropriate
state, as shown in Figure 6-33.

Figure 6-33 The preempt Option Permits a Router to Immediately Take Over as the Active Router
Whenever the Priority Is Higher

Backbone HSRP Group 50

FastEthernet 0/1 Virtual Router FastEthernet 0/1

A B
FastEthernet 0/0 10.1.1.1 FastEthernet 0/0
10.1.1.2 10.1.1.3

IP Address: 10.1.1.50
Default Gateway 10.1.1.1

A (config-if) #standby 50 preempt

The following message is automatically generated as soon as the router becomes active in the
network:
3w1d : %STANDBY-6-STATECHANGE: STANDBY: 50: FastEthernet0/0 state standby Active

HSRP Hello Timers


An HSRP-enabled router sends hello messages to indicate that it is running and that it can
become either the active or standby router. The hello message contains the router’s priority, as
1439_CCNP_3.book Page 374 Wednesday, October 27, 2004 9:54 AM

374 Chapter 6: Redundancy

well as a hellotime and holdtime value. The hellotime value indicates the interval between the
hello messages what the router sends. The holdtime value specifies how long the current hello
message is considered valid. If an active router sends a hello message, receiving routers con-
sider that hello message valid for one holdtime. The holdtime value should be at least three
times the value of the hellotime.
The hellotime and holdtime parameters can be configured. To configure the time between hel-
los and the time before other group routers declare the active or standby router “down,” enter
the following command in interface configuration mode:
standby group-number timers hellotime holdtime

■ group-number—Optional. The group number on the interface to which the timers


apply. The default is 0.
■ hellotime—The hello interval in seconds. This is an integer from 1 to 255. The default
is 3 seconds.
■ holdtime—The time before the active or standby router is declared down. This is an
integer from 1 to 255. The default is 10 seconds.
In Figure 6-34, the hellotime is set to 5 seconds, and the holdtime is set to 15 seconds. To
reinstate the default standby timer values, enter the no standby group timers command.

Figure 6-34 The HSRP Hello and Hold Timers Can Be Configured

Backbone HSRP Group 50

FastEthernet 0/1 Virtual Router FastEthernet 0/1

A B
FastEthernet 0/0 10.1.1.1 FastEthernet 0/0
10.1.1.2 10.1.1.3

IP Address: 10.1.1.50
Default Gateway 10.1.1.1

A (config-if) #standby 50 timers 5 15


1439_CCNP_3.book Page 375 Wednesday, October 27, 2004 9:54 AM

HSRP Configuration 375

HSRP Interface Tracking


In many situations, an interface’s status directly affects which router needs to become the
active router, particularly when each router in an HSRP group has a different path to
resources within the campus network.
In Figure 6-35, Routers A and B reside in a branch office. These two routers each support a
FastEthernet link to the backbone. Router A has the higher priority and is the active forward-
ing router for standby Group 50. Router B is the standby router for that group. Routers A and
B exchange hello messages through their FastEthernet 0/0 interfaces.

Figure 6-35 The HSRP Interface Tracking Option Lets the Standby Router Become Active When an
Uplink Fails on the Active Router

Backbone HSRP Group 50

FastEthernet 0/1 Virtual Router FastEthernet 0/1

A B
FastEthernet 0/0 10.1.1.1 FastEthernet 0/0
10.1.1.2 10.1.1.3

IP Address: 10.1.1.50
Default Gateway 10.1.1.1

A (config-if) #standby 50 track fastethernet 0/1 55

If Router A FastEthernet 0/1 goes down, Router A loses the direct connection to the back-
bone. Although this doesn’t prevent traffic from reaching the backbone, it does lead to an
inefficient traffic flow. The FastEthernet 0/0 interface on Router A is still active, so packets
destined for the core are still sent to Router A and are forwarded in turn to Router B, regard-
less of HSRP. The standby track option can be used to prevent this situation (in conjunction
with the standby preempt command).
To configure HSRP tracking, enter the following command in interface configuration mode:
standby group-number track type number interface-priority
1439_CCNP_3.book Page 376 Wednesday, October 27, 2004 9:54 AM

376 Chapter 6: Redundancy

The value indicated by the standby track command is the value that gets decremented from
the node’s priority if the specified interface goes down. Multiple standby track commands
can be used to list multiple interfaces. If multiple interfaces fail, the decrement values are
cumulative. For example, if the FastEthernet 0/0 interface on Router A goes down, the
router’s HSRP priority is lowered by 55. Because this is lower than the default priority being
used by Router B, Router B takes over as the active router, providing optimal flow to the
backbone.

Verify HSRP Configuration


To display the status of the HSRP router, enter the following command in privileged mode:
show standby type-number group brief

■ type-number—Optional. The target interface type and number for which output is
displayed.
■ group—Optional. A specific HSRP group on the interface for which output is displayed.
■ brief—Optional. Displays a single line of output summarizing each standby group.
If none of the optional interface parameters are used, the show standby command displays
HSRP information for all interfaces, as shown in Example 6-2.

Example 6-2 The show standby Command Displays Useful HSRP Information

ISP#show standby
FastEthernet0/0 - Group 50
Local state is Active, priority 95, may preempt
Hellotime 3 holdtime 10
Next hello sent in 00:00:00.782
Hot standby IP address is 10.1.1.1 configured
Active router is local
Standby router is 10.1.1.3 expires in 00:00:09
Standby virtual mac address is 0000.0c07.ac32
Tracking interface states for 1 interface, 0 up:
Down FastEthernet0/1 Priority decrement: 55

Lab 6.5.1 Hot Standby Router Protocol


In this lab exercise, you configure HSRP on a pair of routers to provide redundant
router services to a network.
1439_CCNP_3.book Page 377 Wednesday, October 27, 2004 9:54 AM

HSRP Configuration 377

Lab 6.5.2 Multigroup Hot Standby Router Protocol


In this lab exercise, you configure Multigroup Hot Standby Router Protocol
(MHSRP) on a pair of routers to provide redundant router services to a network.

HSRP over Trunk Links


To configure HSRP over an Interswitch Link (ISL) between VLANs, follow these steps:
Step 1 Define the encapsulation format.
Step 2 Define an IP address.
Step 3 Enable HSRP.
HSRP is also supported over 802.1Q trunks.
Figure 6-36 and Example 6-3 illustrate the configuration for two HSRP-enabled routers par-
ticipating in two separate VLANs using ISL. Running HSRP over ISL allows users to config-
ure redundancy between multiple routers that are configured as front ends for VLAN IP
subnets. By configuring HSRP over ISL, you can eliminate situations in which a single point
of failure causes traffic interruptions.

Figure 6-36 Network Topology for Configuring HSRP over Trunk Links

VLAN 10 VLAN 20 VLAN 10 VLAN 20

ISL Link Carrying Both


VLAN 10 and 20 Traffic

ISL Link Carrying Both ISL Link Carrying Both


VLAN 10 and 20 Traffic VLAN 10 and 20 Traffic
172.16.10.110 172.16.20.120
Virtual Router for Virtual Router for
A
A VLAN 10 VLAN 20 B

Example 6-3 A Complete HSRP Configuration Involves HSRP Groups, Priority, and Preempt Options

! Configuration for Router A:


interface FastEthernet 1/1.10
encapsulation isl 10
ip address 172.16.10.2 255.255.255.0
standby 1 ip 172.16.10.110

continues
1439_CCNP_3.book Page 378 Wednesday, October 27, 2004 9:54 AM

378 Chapter 6: Redundancy

Example 6-3 A Complete HSRP Configuration Involves HSRP Groups, Priority, and Preempt Options (Continued)

standby 1 priority 105


standby 1 preempt
interface FastEthernet 1/1.20
encapsulation isl 20
ip address 172.16.20.2 255.255.255.0
standby 2 ip 172.16.20.120
standby 2 priority 50
***Production, insert 2-point rule here.
! Configuration for Router B:
interface FastEthernet 1/1.10
encapsulation isl 10
ip address 172.16.10.3 255.255.255.0
standby 1 ip 172.16.10.110
standby 1 priority 50
interface FastEthernet 1/1.20
encapsulation isl 20
ip address 172.16.20.3 255.255.255.0
standby 2 ip 172.16.20.120
standby 2 priority 105
standby 2 preempt

Troubleshooting HSRP
To enable HSRP debugging, the debug standby command is used to enable output of HSRP
state and packet information for all standby groups on all interfaces.
A debug condition was added in Cisco IOS software Release 12.0(2.1) that allows the output
from the debug standby command to be filtered based on interface and group number. This
command uses the debug condition paradigm introduced in Cisco IOS software Release 12.0:
debug condition standby interface group

The interface specified must be a valid interface that can support HSRP.
The debug conditions can be set for groups that do not exist, thereby allowing debug informa-
tion to be captured during the initialization of a new group.
The standby debug order must be configured for any debug output to be produced. If no
standby debug conditions are specified, output is produced for all groups on all interfaces.
Configuring at least one standby debug condition causes the output to be filtered.
1439_CCNP_3.book Page 379 Wednesday, October 27, 2004 9:54 AM

Summary 379

Summary
The resiliency and availability features supported by the Cisco Catalyst family of switches
are well-suited to campus LAN designs that achieve high availability through a combination
of device-level and network-level redundancy. The network resiliency features span Layer 2
and Layer 3 boundaries and may be deployed where needed throughout the three-tiered
Access, Distribution, Core design model.
With some care in configuring the redundant network and tuning the protocol timers within
the switches, interruption of network services caused by network infrastructure failures can
be held in the range of 0 to 10 seconds. With these short failover times, very high network
availability can be achieved by controlling the overall network failure rate.
After completing this chapter, you should be able to
■ Implement hardware redundancy on the Catalyst series of switches
■ Identify the virtual router for a given set of switch block devices
■ Configure HSRP on the switch block devices to ensure continual inter-VLAN routing
■ Maintain packet forwarding by configuring the active and standby HSRP router roles
■ Ensure the role of the active router by assigning a preempt status
1439_CCNP_3.book Page 380 Wednesday, October 27, 2004 9:54 AM

380 Chapter 6: Redundancy

Key Terms
default gateway Provides a definitive location for IP packets to be sent in case the source
device has no IP routing functionality built into it. This is the method most end stations use to
access nonlocal networks. The default gateway can be set manually or learned from a DHCP
server.
Gateway Load Balancing Protocol (GLBP) A Cisco-proprietary protocol that protects data
traffic from a failed router or circuit, like HSRP and VRRP, while allowing packet load shar-
ing between a group of redundant routers.
hello interval The time that elapses between the sending of HSRP hello packets. The
default is 3 seconds.
holdtime The time it takes before HSRP routers in an HSRP group declare the active router
to be down. The default is 10 seconds.
Hot Standby Router Protocol (HSRP) The Layer 3 Cisco-proprietary protocol that allows
a set of routers on a LAN segment to work together to present the appearance of a single vir-
tual router or default gateway to the hosts on the segment. HSRP enables fast rerouting to
alternate default gateways should one of them fail.
HSRP group Routers on a subnet, VLAN, or subset of a subnet participating in an HSRP
process. Each group shares a virtual IP address. The group is defined on the HSRP routers.
HSRP state The descriptor for the current HSRP condition for a particular router interface
and a particular HSRP group. The possible HSRP states are Initial, Learn, Listen, Speak,
Standby, and Active.
ICMP Router Discovery Protocol (IRDP) Hosts supporting IRDP dynamically discover
routers to access nonlocal networks. IRDP allows hosts to locate routers (default gateways).
Router discovery packets are exchanged between hosts (IRDP servers) and routers (IRDP
clients).
preempt An HSRP feature that lets a router with the highest priority immediately assume
the active role at any time.
priority An HSRP parameter used to facilitate the election of an active HSRP router for an
HSRP group on a LAN segment. The default priority is 100. The router with the greatest pri-
ority for each group is elected as the active forwarder for that group.
proxy ARP Proxy ARP allows an Ethernet host with no knowledge of routing to communi-
cate with hosts on other networks or subnets. Such a host assumes that all hosts are on the
same local segment and that it can use ARP to determine their hardware addresses. The proxy
ARP function is handled by routers.
1439_CCNP_3.book Page 381 Wednesday, October 27, 2004 9:54 AM

Check Your Understanding 381

Server Load Balancing (SLB) Balances services across numerous servers at speeds of mil-
lions of packets per second. Commonly deployed with the Cisco IOS software on Catalyst
6000 family of switches. SLB is a software solution using the advanced application-specific
integrated circuits (ASICs) on the Catalyst 6000.
Single Router Mode (SRM) Addresses the drawback of the previous HSRP-based MSFC
redundancy scheme (designated MSFC versus nondesignated MSFC). When SRM is
enabled, the nondesignated router is online, but all its interfaces are down. Thus, it does not
hold any routing table information. This means that if the DR fails, there will be some delay
before the nondesignated router coming online has a complete route table. To help account
for this, the information being used before the failure by the Supervisor for Layer 3 forward-
ing is maintained and updated with any new information from the new designated router.
tracking This HSRP feature allows you to specify other interfaces on the router for the
HSRP process to monitor. If the tracked interface goes down, the HSRP standby router takes
over as the active router. This process is facilitated by a decrement to the HSRP priority
resulting from the tracked interface line protocol going down.
Virtual Router Redundancy Protocol (VRRP) Provides functions equivalent to HSRP but
is supported by multiple vendors. It is designed to eliminate a single point of failure that is
unavoidable in static default routing environments.

Check Your Understanding


Use the following review questions to test your understanding of the concepts covered in this
chapter. Answers are listed in Appendix A, “Check Your Understanding Answer Key.”
1. With redundant Supervisor Engines and MSFCs in a Catalyst 6500 switch running
SRM, which of the following statements is accurate?
A. The nondesignated MSFC is active and has the same configuration as the designated
MSFC.
B. The nondesignated MSFC is inactive and has the same configuration as the desig-
nated MSFC.
C. The nondesignated MSFC is inactive and has a configuration distinct from the
designated MSFC.
D. The nondesignated MSFC is active and has a configuration distinct from the des-
ignated MSFC.
1439_CCNP_3.book Page 382 Wednesday, October 27, 2004 9:54 AM

382 Chapter 6: Redundancy

2. The GLBP router responsible for allocating MAC addresses is which of the following?

A. Active virtual gateway

B. Active virtual forwarder

C. Primary virtual forwarder

D. Secondary virtual forwarder


3. The GLBP router responsible for forwarding packets sent to a particular MAC address
is which of the following?
A. Active virtual gateway

B. Active virtual forwarder

C. Primary virtual forwarder

D. Secondary virtual forwarder


4. Which IETF standard introduced in RFC 2338 parallels the Cisco-proprietary HSRP?

A. HSRP 2

B. IRDP

C. GLBP

D. VRRP
5. How many virtual MAC addresses are used per HSRP group?

A. 1

B. 2

C. 3

D. 4
6. SLB is an IOS-based solution defining a virtual server that represents a group of what?

A. Real servers in separate intranets

B. Virtual servers in a server farm

C. Real servers in a server farm

D. Virtual servers in separate intranets


1439_CCNP_3.book Page 383 Wednesday, October 27, 2004 9:54 AM

Check Your Understanding 383

7. How many standby routers can there be in a given HSRP group?

A. 1

B. 2

C. 3

D. 4
8. HSRP can be configured on distribution layer Catalyst 3550 switches using switch
virtual interfaces. However, on distribution layer routers, multigroup HSRP is config-
ured on trunk links using what?
A. Null interfaces

B. Loopbacks

C. Bridge virtual interfaces

D. Subinterfaces
9. When configuring HSRP, each HSRP router interface must be configured with which of
the following? (Select all that apply.)
A. A virtual MAC address

B. A real MAC address

C. A virtual IP address

D. A real IP address
10. Which HSRP option(s) is/are used to guarantee an immediate change to active state on
an HSRP router?
A. preempt

B. tracking

C. priority

D. hello time
1439_CCNP_3.book Page 384 Monday, November 1, 2004 11:16 AM

Objectives
After completing this chapter, you will be able to perform tasks related to the following:
■ Describe some of the major components of a Cisco AVVID (Architecture for Voice,
Video, and Integrated Data) network solution.
■ Explain how Layer 2 multicast addresses map to Layer 3 multicast addresses.
■ Explain the role of Internet Group Management Protocol (IGMP) in multicasting.
■ Understand the purpose of IGMP snooping and Cisco Group Management Protocol
(CGMP) with switched traffic.
■ Understand the operation of shared trees versus source trees in multicast routing.
■ List the major multicast routing protocol solutions.
■ Describe the role of the auxiliary virtual LAN (VLAN) with voice traffic.
■ Explain the role of class of service (CoS), type of service (ToS), and Differentiated
Services Code Point (DSCP) in traffic classification.
■ Understand the importance of quality of service (QoS) with IP Telephony solutions.
1439_CCNP_3.book Page 385 Wednesday, October 27, 2004 9:54 AM

Chapter 7

Cisco AVVID
Traditionally, separate networks have been designed and implemented within the enterprise for
data, voice, and video applications. These have been deployed in parallel and operated in isola-
tion, often implemented and managed by separate teams.
In the past, networking vendors typically offered similar enterprise network architectures that
were, almost without exception, proprietary, closed, and nonhierarchical.
These separate networks encompass enterprise local and wide-area networks. They have been
built to interconnect private branch exchange (PBX) equipment, H.320 videoconferencing
equipment, and routers.
The networks have been provisioned over dedicated leased lines for PBX and H.320 video, with
a combination of leased lines, Frame Relay, and ATM for data.
As client/server networking grew, the needs of enterprises were also evolving. Applying technol-
ogy to business practices such as sales, support, customer response management, accounting,
and supply chain was reaping tremendous benefits in increased efficiency and lower costs. Many
of these new technologies supported entirely different business models (for example, business-
to-consumer e-commerce, business-to-business online exchanges, and so on). In other cases,
these technologies were used to reengineer existing business practices. In all cases, the needs for
reliability, performance, and ease of deployment and management remain crucial, because these
applications have become more critical to an enterprise’s success (whether profit-making or
service-oriented).
In networking today, corporations are looking for strategies to integrate disparate networking
technologies over a single common network infrastructure. This trend started many years ago in
the internetworking area when corporate networks began the migration of delay-sensitive, mis-
sion-critical Systems Network Architecture (SNA) data traffic across an IP infrastructure. Now,
people are examining the existing and often separate data, voice, and video network infrastruc-
tures and determining the most efficient ways of bringing them together.
1439_CCNP_3.book Page 386 Wednesday, October 27, 2004 9:54 AM

386 Chapter 7: Cisco AVVID

Most corporations have voice networks anchored around PBX systems connected to a Public
Switched Telephone Network (PSTN), but most data networks are IP-based and anchored
around switches and routers. Where traditional telephony in fixed 64-kbps bandwidth incre-
ments is carried across a circuit-switched PBX infrastructure, other dynamic data applica-
tions are consolidated over an intelligent IP-based backbone.

Introduction to Cisco AVVID


The Cisco Architecture for Voice, Video, and Integrated Data (AVVID) is composed of a
holistic network design infrastructure. IP Telephony, campus LAN switching, wireless net-
works, security, storage networking, and multicasting are major components addressed by
AVVID. This section discusses AVVID at a high level, describing how it is applied in produc-
tion networks.

Examining the Cisco AVVID Framework


With today’s separate infrastructures, two strategic directions toward the convergence of data,
voice, and video are possible, as illustrated in Figures 7-1 and 7-2.

Figure 7-1 A Typical Network Infrastructure Separates the Voice and Data Components

Voice Network IP Data Network

PSTN IP WAN

PBX Catalyst Backbone


Gigabit Ethernet

Proprietary
Digital Phones

End-User PC
100 M Ethernet
1439_CCNP_3.book Page 387 Wednesday, October 27, 2004 9:54 AM

Introduction to Cisco AVVID 387

Figure 7-2 A Converged Voice and Data Network Is Now Common in Enterprise Networks

Coverage of Network Coverage of Network


(Data Over Voice) (Data Over Voice)

PSTN IP WAN OR PSTN IP WAN

PBX Catalyst Backbone


Gigabit Ethernet
Switches
Routers

IP Telephony to the Desktop Video Desktop

One approach calls for the use of the PBX to support the kinds of interfaces and bandwidth
required by today’s IP-based data applications. This means interfaces such as Ethernet, Fast
Ethernet, Gigabit Ethernet, and others on PBX platforms. Most data desktops are now con-
nected at speeds of 10 or 100 Mbps, making this a strategy without merit. Fundamentally, the
PBX is a time-division multiplexing (TDM) system built on 64-kbps time slots with aggregate
capacity in the tens of megabits per second. Although this is adequate for voice only, any
attempt to drive data bandwidths shows that a whole new breed of platform would be required
beyond the PBX.
It is also interesting to look back in history at other attempts to accomplish this integration.
In the 1980s, when a 2400-bps modem was standard and a 9600-bps modem was almost
unheard of, Integrated Services Digital Network (ISDN) at 64 kbps per channel was being
touted as the next high-speed desktop technology. Naturally this was well-suited to be termi-
nated on the PBX, given its conformance to the bandwidth hierarchy of the PBX systems.
Interestingly, this still did not take the marketplace by storm, even before technologies such
as Ethernet were on the radar screen. Vendor investment in traditional PBX technology has
not scaled to meet the demands of a converged network.
Most of the networking innovation during the last ten years has been developed around IP
networks because of the pervasiveness and rapid development of the Internet. This includes
1439_CCNP_3.book Page 388 Wednesday, October 27, 2004 9:54 AM

388 Chapter 7: Cisco AVVID

World Wide Web technology, streaming video, IP Telephony, higher-speed IP transport mech-
anisms, and more intelligence in the network to cope with new classes of delay-sensitive,
mission-critical applications. This has all lead to the future of integrated networks, one in
which data, voice, and video share a common IP data network. Naturally, things will need to
be done to prepare for this eventuality. The first step is to understand the architecture that will
make this convergence a reality and some of the more specific considerations in the data net-
working infrastructure that will make this migration easier.
The Cisco solution for the convergence of data, voice, and video is Cisco AVVID. Cisco
AVVID has three fundamental components, as shown in Figure 7-3:
■ Clients are the user end stations or appliances that are used to communicate with the
network or other users. Some examples are PCs, telephone devices, and video cameras.
■ Applications for Cisco AVVID are written to an open-standards environment and, as
such, will be supplied by both Cisco and third-party application developers. Some
examples are interactive voice response (IVR), call center, and unified messaging.
■ Infrastructure is the network on which both the clients and applications reside. The net-
work is IP-based using intelligence inherent in the platforms to provide the flexibility
and scalability to support the convergence of different media. Examples of network
devices are Catalyst switches, Cisco routers, and voice gateways, as shown in Figure 7-4.

Cisco AVVID Network Infrastructure


Cisco AVVID network infrastructure, illustrated in Figure 7-5, is the network foundation that
is recommended for rapid and seamless deployment of emerging technologies and new Inter-
net business solutions into the retail environment.

Figure 7-3 Cisco AVVID Is Distributed, Adaptive, Open, and Manageable

Clients Infrastructure Applications


Su
Cisco IP Fabric ppo
e rt
rvic
Se
Internet
Management

Cisco
Application
Directory

CallManager
Policy

Technologies
Servers
Message
Cisco SoftPhone Network
Servers
Services
Telephony
Application
Servers
Video Platform Directory
Servers
Content
PCs IP Phones
Servers
Gateway Switch Router
1439_CCNP_3.book Page 389 Wednesday, October 27, 2004 9:54 AM

Introduction to Cisco AVVID 389

Figure 7-4 The Cisco AVVID Framework Integrates IP Networks for Large Organizations

Supply Customer Internet Workforce


E-Learning
Chain Care Commerce Optimization
Internet Cap Gemini
Business EDS Cisco Systems IBM KPMG
Ernest & Young
Integrators
Messaging Policy Management
Collaboration Security
Internet Contact Center
Video on Demand Content Distribution
Middleware Multimedia
Personal Productivity SLA Management
Layer Voice Call Processing Address Management
Intelligent Network Classification

Management
Intelligent

Accounting
Real Time
Balancing

Cisco
Multicast

Services

Services
Caching
Security

Network
Load

DNS
QoS

Services Systems

Network
Platforms

Clients

Figure 7-5 The Cisco AVVID Network Infrastructure Integrates Traditional WAN Technologies with
Modern Metropolitan-Area Network (MAN) Technologies, Such as Dense Wavelength
Division Multiplexing (DWDM)

VM/UM

Router
Metro PoS,
DWDM DPT

Branch Office
West Coast Headquarters
IP WAN
ATM, LL, FR

Rest of World East Coast Headquarters


1439_CCNP_3.book Page 390 Wednesday, October 27, 2004 9:54 AM

390 Chapter 7: Cisco AVVID

As with any architecture, Cisco AVVID relies on a strong and stable foundation. This founda-
tion is built on the multiprotocol routers and multilayer LAN switches that are used as build-
ing blocks for enterprise networks, as shown in Figure 7-6.

Figure 7-6 Cisco AVVID Provides a Cohesive, Integrated, and Optimized Network

Campus Campus
1 2

Cisco Cisco
6500s 6500s

Campus 3 Cisco
6500s
Internet
Router Cisco
Internet
7200s

Frame
Cisco Relay Cisco
2600 2600

Branch
Branch Branch
Office
Office Office
1 – 120

Although best-of-breed solutions might promise high performance for a specific device or
application, performance is limited by the network’s weakest link. Only a cohesive, inte-
grated, optimized network can ensure the best network performance. The Cisco AVVID
network infrastructure is not only tailored to the enterprise’s characteristics, but it is also
thoroughly lab tested and documented to provide the following benefits:
■ Speed—A defined architectural framework and consistent services allow rapid deploy-
ment of new applications and let an enterprise quickly address change without reengi-
neering the network.
■ Reliability—A consistent architectural approach increases network dependability.
■ Flexibility—The architecture allows easy transitions to changing business requirements.
1439_CCNP_3.book Page 391 Wednesday, October 27, 2004 9:54 AM

Introduction to Cisco AVVID 391

■ Interoperability—All equipment and software are configured for the ideal fit that
allows seamless operation. Multiple solutions work together based on a common archi-
tectural approach.
■ Simplification—Products are strategically deployed in alignment with the architectural
framework, resulting in streamlined processes.
■ Reduced cost—The predefined architecture minimizes the resources and time required
to implement network strategies, measurements, and Resource Reservation Protocol
(RSVP) signaling for admission control and reservation of resources.
■ Security—Ensures network security through authentication, encryption, and failover.
Security features include stateful, application-based filtering (context-based access
control), defense against network attacks, per-user authentication and authorization,
and real-time alerts.
■ High availability—Optimizes the design and tools to ensure end-to-end availability for
services, clients, and sessions.

Cisco AVVID Intelligent Network Services


The Cisco AVVID network infrastructure consists of the e-business infrastructure (physical
layer) and intelligent network services, which is composed of numerous networking technol-
ogies and topologies with a corresponding large number of possible designs and architec-
tures. Cisco lab-tested these various full-scale network designs at Research Triangle Park,
North Carolina. The results are captured in Solution Reference Network Design Guides. The
net result is a blueprint of optimal blending of equipment, features, and management tools
that match business criteria. In addition to the physical layer, Cisco deploys Intelligent Network
Services, such as quality of service (QoS) and security, to keep the network at peak perfor-
mance.
QoS manages a network’s delay, delay variation (jitter), bandwidth, and packet loss parame-
ters to meet the diverse needs of voice, video, and data applications. QoS features provide
value-added functionality, such as network-based application recognition (NBAR) for classify-
ing traffic on an application basis, a service assurance agent (SAA) for end-to-end QoS mea-
surements, and RSVP signaling for admission control and reservation of resources. Figure 7-7
illustrates queuing that prioritizes voice traffic. Low-latency queuing introduces priority
queuing (PQ) for voice traffic and relies on Weighted Fair Queuing (WFQ) for the remaining
traffic classes.
1439_CCNP_3.book Page 392 Wednesday, October 27, 2004 9:54 AM

392 Chapter 7: Cisco AVVID

Figure 7-7 Low-Latency Queuing Introduces a Priority Queue for Voice Traffic and Relies on
Weighted Fair Queuing for Remaining Traffic Classes

Router
VoIP
1 1
(High)

Data V V
2 2 PQ 4 3 2 1 1 1
(Low)
WAN
Circuit
Data WFQ
3 3 3 3
(Low)

Data
4 4 4 4
(Low)

Security must be treated as an integral element of any Cisco AVVID network. An organiza-
tion’s communications network is the basic environment connecting all users, servers, appli-
cations, and service providers. Implementing a robust security suite provides the best defense
against possible information loss, tampering, or productivity disruption. Cisco’s security suite
emphasizes three key areas:
■ Internal network security—Ensuring that the internal network is secure includes
tracking physical, endpoint, application, and Layer 2 security issues.
■ External network security—External network security focuses on securing the inter-
face between an organization’s internal network and the outside world (the Internet
edge).
■ Network identity—In considering a network’s overall security scheme, it is essential
to establish a framework that allows the network administrator to implement identity-
based network access control and policy enforcement, right down to the user and indi-
vidual access port level.
Cisco AVVID network infrastructure capabilities present an array of both device-based and
server-based security applications and features. Access control lists (ACLs), firewalls, server-
based authentication, intrusion detection systems (IDSs), and virtual private network (VPN)
capabilities can be integrated into a seamless security environment. Figure 7-8 illustrates
these technologies as implemented in a network.
1439_CCNP_3.book Page 393 Wednesday, October 27, 2004 9:54 AM

Introduction to Cisco AVVID 393

Figure 7-8 The Cisco AVVID Network Infrastructure Integrates an Impressive Array of Security
Technologies

Focused Layer Host IDS Local


4-7 Analysis Attack Mitigation

SMTP Content
Inspection

Spoof Mitigation
Basic Filtering ISP A
To Edge
Distribution
Stateful Packet
Spoof Mitigation
Filtering Basic
(D)DoS Rate-
Layer 7 Filtering To Limiting
Host DoS Mitigation VPN/Remote
Broad Layer Access
4-7 Analysis

Focused Layer
4-7 Analysis
Inspect Outbound
Traffic for
Unauthorized URLs

High Availability
High availability optimizes design and tools to ensure end-to-end availability for services,
clients, and sessions. Tools include reliable, fault-tolerant network devices to automatically
identify and overcome failures. Also, resilient network technologies, such as Hot Standby
Router Protocol (HSRP), bring resilience to the critical junction between hosts and backbone
links. Simple Server Redundancy Protocol (SSRP) communicates between router and ATM
switch groups to detect device failures and initiate automatic reroutes within one second of
failover time.
Determining how resilient a network is to change or disruption is a major concern for net-
work managers. This assessment of network availability is critical. It is essential that every
network deployment emphasize, availability as the very first consideration in a baseline net-
work design.
1439_CCNP_3.book Page 394 Wednesday, October 27, 2004 9:54 AM

394 Chapter 7: Cisco AVVID

Availability must be viewed from the user’s perspective. To the user, the network is down
regardless of whether an application fails, a router dies, or a piece of fiber is cut. Here are
some key availability issues to address:
■ Hardware redundancy—This is often the first level of redundancy in the network.
Cisco offers, in its modular products, for example, options for redundant supervisor
engines and dual in-line power supplies. This often provides the first backstop against
a network failure.
■ Protocol resiliency—Good design practices dictate how and when to use protocol
redundancy, including load sharing, convergence speed, and path redundancy handling.
Contrary to popular belief, if some redundancy is good, more redundancy is not neces-
sarily better.
■ Network capacity design—Good design practices include capacity planning. How
much traffic can a connection handle in the worst case? You must consider whether a
link can handle double the traffic when a redundant link fails. Capacity planning must
be included during the network design phase to ensure the smooth integration of new
technologies (such as videoconferencing). Figure 7-9 shows redundant links as com-
monly deployed.
■ Management—Includes the LAN Management Solution for advanced management of
the Catalyst multilayer switches; the Routed WAN Management Solution for monitor-
ing, traffic management, and access control to administer the routed infrastructure of
multiservice networks; the Service Management Solution for managing and monitoring
service-level agreements; and the VPN/Security Management Solution for optimizing
VPN performance and security administration.
■ Multicasting—Provides bandwidth-conserving technology that reduces traffic by
simultaneously delivering a single stream of information to thousands of corporate
recipients and homes. Multicasting enables distribution of videoconferencing, corpo-
rate communications, distance learning, distribution of software, and other applica-
tions. Multicast packets are replicated in the network by Cisco routers enabled with
Protocol-Independent Multicast (PIM) and other supporting multicast protocols, result-
ing in the most efficient delivery of data to multiple receivers.
1439_CCNP_3.book Page 395 Wednesday, October 27, 2004 9:54 AM

Introduction to Cisco AVVID 395

Figure 7-9 Capacity Planning Must Be Included During the Network Design Phase to Ensure the
Smooth Integration of New Technologies

Network Design

IP WAN

End-User PC
100 M Ethernet

Cisco AVVID Network Solutions


Cisco AVVID network solutions include IP Telephony, IP videoconferencing, wireless LANs,
security, VPNs, content networking, contact centers, and storage networking. The following
sections discuss these technologies in greater detail.

IP Telephony
Built on the Cisco AVVID network infrastructure, a Cisco AVVID IP Telephony solution
brings the promise of high-quality IP voice and fully integrated communications to reality.
Through IP Telephony, single-site and multisite enterprises can use IP as a primary voice path
with the traditional Public Switched Telephone Network (PSTN) serving as a redundant voice
path. The easy-to-deploy, standards-based system delivers high voice quality while decreas-
ing the reliance on the PSTN and significantly reducing costs (see Figure 7-10).
1439_CCNP_3.book Page 396 Wednesday, October 27, 2004 9:54 AM

396 Chapter 7: Cisco AVVID

Figure 7-10 Cisco’s IP Telephony Solution Provides an Integrated Voice and Data Network

CallManager
Cluster Applications
(VMail, IVR, ICO,...)

GK

V V

PSTN

West Coast Headquarters Branch Office


(with SRST and APPs) (with Call Processing and Apps)

IP WAN

Rest of World
East Coast
Headquarters

IP Videoconferencing
Using an IP-based videoconferencing solution makes it possible to run interactive video over
an IP network, saving companies thousands of dollars a month by converging voice, video,
and data traffic over a common path. H.323 builds on top of existing IP data networks, ulti-
mately saving money and scaling to larger deployments. Distance learning and business
meetings are two common applications that can be deployed with H.323 over IP data net-
works (see Figure 7-11).

Wireless LANs
Wireless LANs let users establish and maintain a wireless network connection throughout or
between buildings, without the limitations of wires or cables, as illustrated in Figure 7-12.
1439_CCNP_3.book Page 397 Wednesday, October 27, 2004 9:54 AM

Introduction to Cisco AVVID 397

Figure 7-11 The Cisco AVVID Infrastructure Supports IP Videoconferencing

H.320 MCU

H.320 Endpoints
Headquarters
with one or more PSTN
zones, and local PSTN ISDN
and MCU access.
H.323 to H.320 MCU
MCU Gateway

H.323 to H.320
H.323 Gateway
Terminals
H.323
Terminals
Gatekeeper
QoS Enabled
Proxy
IP WAN
Gatekeeper
Large Branch
Proxy
with one or more zones, local
PSTN, and MCU access.

Small Branch
with no local gatekeeper, PSTN
or MCU services, all services will be
handheld at Headquarters site.

Cisco AVVID Security


Cisco offers a comprehensive array of enterprise network security solutions to make imple-
menting and maintaining good network security easier and more cost-effective, as shown in
Figure 7-13.

Virtual Private Networks


Enterprise VPN enables customer connectivity deployed on a shared (public) infrastructure
with the same policies as a private network, where users expect the same application behav-
ior, performance, and connectivity (see Figure 7-14).
1439_CCNP_3.book Page 398 Wednesday, October 27, 2004 9:54 AM

398 Chapter 7: Cisco AVVID

Figure 7-12 Wireless LANs Are Now a Fundamental Component of Most Modern Networks

Enterprise
Central Site
Enterprise
Branch
Enterprise
WAN
Service
Provider
Telecommuter/
SOHO

Standalone
Office

Single-Site
Small-Medium Business (SMB) Multisite
Enterprise Large Enterprise

Figure 7-13 An Integrated Security Solution Is Critical in Modern Network Deployments

Focused Layer Host IDS Local


4-7 Analysis Attack Mitigation

SMTMP Content
Inspection

Spoof Mitigation
Basic Filtering ISP A
To Edge
Distribution
Stateful Packet
Spoof Mitigation
Filtering Basic
(D)DoS Rate-
Layer 7 Filtering To Limiting
Host DoS Mitigation VPN/Remote
Broad Layer Access
4-7 Analysis

Focused Layer
4-7 Analysis
Inspect Outbound Traffic for
Unauthorized URLs
1439_CCNP_3.book Page 399 Wednesday, October 27, 2004 9:54 AM

Introduction to Cisco AVVID 399

Figure 7-14 VPNs Are an Ideal Solution for Remote Users and Telecommuters

Site-to-Site VPN
Large/Small Branch

Central Site

Service Provider/
Internet
VPN
Concentrator
or Headend
SOHO VPN
(Small Office Home Office)

Remote Access (SW Client)

Content Networking
Content Networking, shown in Figure 7-15, allows enterprises to maximize the impact of
communicating topology using the web by overcoming the modern-day bandwidth issues
of delivering rich media to the desktop. Content Networking solutions guarantee that quality
video, rich audio, and large graphics, as well as other high-bandwidth files, can be delivered
with speed, accuracy, and consistency, dramatically increasing the impact of the communica-
tions programs.

IP Contact Center
An integral part of Cisco AVVID is the Cisco IP Contact Center (IPCC), which delivers intel-
ligent call routing, network-to-desktop computer telephony integration (CTI), and multime-
dia contact management to contact center agents over an IP network. By combining software
automatic call distribution (ACD) functionality with IP Telephony in a unified solution, IPCC
lets companies rapidly deploy a distributed contact center infrastructure to support their global
e-sales and e-service initiatives.
1439_CCNP_3.book Page 400 Wednesday, October 27, 2004 9:54 AM

400 Chapter 7: Cisco AVVID

Figure 7-15 Content Networking Is a Relatively New Technology That Will Soon Be a Standard
Component of Enterprise Networks

Internet
WAN:
Branch Offices, SOHO, SMB Services_
1: Media On Demand
2: Live Broadcast
3: Re-Broadcast
WAN
Internet Edge

Campus Network:
Large Users Groups

IPTV Archive Server

Content Engines

Content Switches
Benefits_
Content Distribution Manager 1: Bandwidth Optimization
2: Application Scalability
IPTV Broadcast Server 3: Reduced Response Time

Data Center Headquarters:


Server Farms: Critical and Origin Servers

Storage Networking
The Cisco Storage Networking strategy, shown in Figure 7-16, is composed of four comple-
mentary technology areas:
■ IP access to storage—High-speed access to block storage over IP networks
■ Network attached storage—High-performance access, data protection, and disaster
recovery for file-based storage over an IP network
■ Storage over metro optical—Extension of storage networks across metropolitan-area
networks (MANs) using an optical network infrastructure
■ Storage over WAN—Fast, secure, and highly available storage networks interconnect
over WANs
As an element of AVVID, Cisco Storage Networking allows customers to adopt a strategy for
accessing, managing, and protecting their growing information resources across a consoli-
dated IP, Gigabit Ethernet, Fiber Channel, and optical network infrastructure.
1439_CCNP_3.book Page 401 Wednesday, October 27, 2004 9:54 AM

Introduction to Cisco AVVID 401

Figure 7-16 Storage Networking Is Another Relatively New Technology That Provides High-Speed
IP Access to Storage

LAN/WAN WAN
iSCSI: Storage pooling in NT/ FCIP: Connectivity between Fiber
Open Storage System environment Channel SAN islands over IP

iSCSI-enabled
Server Pool
Fiber
Channel Fiber
MAN
SAN Channel Metro Optical:
SAN Connectivity betwen
Fiber Channel SAN
islands over DWDM
Catalyst
6500
FCIP

IP Network
iSCSI
iSCSI
Storage
5420
Optical
MAN
Fiber Metro Fiber
Channel 15540 Channel
SAN SAN
Storage Pool

Primary Site Disaster


Recovery Site

Interactive Media Activity Matching: Cisco AVVID Network Solutions


This Interactive Media Activity helps you better understand the Cisco AVVID
network.

Cisco AVVID Network Implementation Example


Figure 7-17 illustrates a typical deployment of a converged network combining data, voice,
and video over a single infrastructure. The network is composed of a single or several large
headquarters sites, a larger number of branch offices, and individual telecommuter sites.
From a telephony point of view, whether a physical handset or a softphone application on a
PC, the devices are treated as IP endpoints on an IP infrastructure typically serving Ethernet
to the end user. Voice calls inside a site traverse the IP LAN until the exit point from the site
where, as a first choice, the calls cross the IP WAN backbone to save on public network
toll costs. If for some reason this IP WAN is “full” or unavailable, the call is automatically
rerouted across the PSTN. Either way, the call’s path is transparent to the end user. Gateways
are used at the edge of each site to provide a path to the PSTN, which is also the primary path
1439_CCNP_3.book Page 402 Wednesday, October 27, 2004 9:54 AM

402 Chapter 7: Cisco AVVID

for local inbound and outbound calls. This level of integration allows for very simple coordi-
nated dial plans in which an entire enterprise can use four- or five-digit dialing, as appropriate,
for internal calls.

Figure 7-17 A Converged Voice, Video, and Data Cisco AVVID Solution Relies on Cisco
CallManager

Cisco CallManager

Router/Gateway

Cisco CallManager V

Cisco CallManager
Voice
Messaging PSTN
V

IP WAN
V V
Router/Gateway

V
Router/Gateway Branch Office
Telecommuter

Router/Gateway

The technology used in the IP WAN allows for tremendous flexibility in the design of the
intranet. Because the IP protocol is the underlying carrier of data, voice, and video, any
technology such as PPP, Frame Relay, ATM, dark fiber (installed but unused fiber), digital
subscriber line (DSL), Synchronous Optical Network (SONET), or wavelength division mul-
tiplexing (WDM) can be used to construct the network. This allows for maximum flexibility
and agility on the part of a network manager to take advantage of new high-speed WAN ser-
vices from carriers, without making major changes to the converged IP network. However,
routers at the edge of the WAN must employ the proper QoS techniques to ensure that voice
traffic remains high-quality, even in congested conditions. Techniques such as low-latency
queuing, weighted fair queuing, and priority queuing are examples of necessary technologies
in a converged network.
1439_CCNP_3.book Page 403 Wednesday, October 27, 2004 9:54 AM

Introduction to Cisco AVVID 403

Familiar applications, such as voice messaging, are also easily integrated into this converged
networking environment. Because the voice being carried across the network is encoded in
IP, a new breed of IP-enabled unified-messaging solutions allows users to access both voice
mail and e-mail from a common server. This can be accomplished with either the e-mail
application or through a next-generation IP Telephony handset. Figure 7-18 illustrates unified
messaging.

Figure 7-18 Unified Messaging Allows Faxes and Voice Messages to Be Accessed Through a
User’s E-Mail Application

Although the nirvana of a converged network has widespread appeal to many, the reality is
that every corporation already has existing voice and data networks, a scenario that requires
finding simple ways to migrate to a converged network.

Legacy Migration
Although building a converged network with Cisco AVVID has obvious advantages, some
existing legacy voice and video systems require a seamless migration into the New World. One
example might be a scenario where an existing PBX has reached capacity and its growth is
dependent on IP Telephony. In some cases, the existing voice mail system still has the capacity
to sustain the additional users and it is desired to maintain the existing system in production.
In Figure 7-19, a voice mail system is connected to the PBX using multiple analog voice
ports to carry voice traffic and a signaling line called a Simple Messaging Desktop Interface
(SMDI) that passes information, such as whose mailbox greeting to play on which particular
voice port, to the voice mail system. This is one of many ways to network voice mail to a PBX.
1439_CCNP_3.book Page 404 Wednesday, October 27, 2004 9:54 AM

404 Chapter 7: Cisco AVVID

Figure 7-19 An Intricate Process Is Required to Migrate from a Legacy PBX Network to a Cisco
AVVID Network

Cisco CallManager
Legacy Voice Mail

SMDI SMDI

Voice
VM Gateway
V Path

T1 PRI
V
PSTN
Gateway

Transparent Migration

AVVID Network Legacy PBX

The first part of the migration to consider is establishing uniform dialing plans that are the
same on both the legacy and Cisco AVVID networks. This migration is easily achieved using
either a standalone gateway or one of the many router/gateway combinations available from
Cisco. Regardless of which side of the network the user is on, the incoming and outgoing
calls from the outside world appear exactly the same (whether direct inward dial or an operator
and extensions are used). Internal dialing using a shorter dial plan (perhaps four or five digits)
can also be maintained.
From a voice mail perspective, Cisco CallManager also supports SMDI for control of a voice
mail system. Coupled with analog gateways connecting to the same voice mail, calls on either
side of the network appear exactly the same to voice mail.
In the video world, it is common to have H.320-based videoconferencing systems, each with
its own PSTN network connections. LAN-based H.323 video systems also are commonly
deployed in many companies, such as Microsoft NetMeeting, which uses H.323 for video-
conferencing and shared collaboration. Again, the Cisco AVVID solution provides several
different ways to preserve an investment in legacy systems while investing in converged
network solutions.
Figure 7-20 illustrates two different scenarios.
1439_CCNP_3.book Page 405 Wednesday, October 27, 2004 9:54 AM

Introduction to Cisco AVVID 405

Figure 7-20 A Video Gateway or a Video Terminal Adapter Can Be Used to Migrate from a Legacy
H.320 Network to a Converged Video Network

Legacy Legacy
H.320 PSTN H.320
Network Endpoint

Video
Video
Terminal
Gateway
Adapter

Converged Converged
Video Video
Network Network
(H.323) (H.323)

On the left side of Figure 7-20, there might be a whole network of H.320 systems deployed
by the corporation or customers. Using a Cisco video gateway enables communication
between the converged H.323 network and the legacy video network. Using a Cisco video
gateway would also allow customers or vendors who have only H.320 systems to communi-
cate with a new network of H.323-only systems.
Additionally, on the right side of Figure 7-20, individual H.320 endpoints can be networked
seamlessly in an H.323 network with the use of a Cisco video terminal adapter.
The fact that every major networking vendor has announced plans for IP Telephony solutions
leads to the conclusion that the convergence of data, voice, and video networks is inevitable.
The only possible convergence solution is to merge the existing voice and video networks
onto the IP data network. For this to succeed, many aspects of the intelligence of the IP data
network need to be exercised.
Lastly, tools that aid in the migration from legacy voice and video networks toward networks
converged on IP make it possible for mass deployment of networks based on the Cisco
AVVID architecture.
The next section introduces IP multicast technology.
1439_CCNP_3.book Page 406 Wednesday, October 27, 2004 9:54 AM

406 Chapter 7: Cisco AVVID

Examining Multicast in a Multilayer Switched


Network
Multicasting is the process of sending a stream of data from a single source to several recipi-
ents without having to replicate a unicast stream for each recipient. Some Layer 2 and Layer 3
multicast addresses are formally associated, as described in the upcoming section “Layer 2
Multicast Addressing.” IGMP is used to allow hosts to request participation in or leave particu-
lar multicast sessions. CGMP is a Cisco legacy technology used on low-end Layer 2 Catalyst
switches to optimize multicast traffic flow through the switches. It has largely been replaced
by a newer technology called IGMP snooping.

Multicast Overview
Most campus networks today support intranet applications that operate between one sender
and one receiver. However, this paradigm is rapidly changing. In the emerging campus net-
work, a demand exists for intranet and multimedia applications in which one sender transmits
to a group of receivers simultaneously. These types of applications include the following:
■ Transmitting a corporate message to employees
■ Video and audio broadcasting
■ Interactive video distance learning
■ Transmitting data from a centralized data warehouse to multiple departments
■ Communication of stock quotes to brokers
■ Collaborative computing
For example, an internal technical support facility might use multicast file transfer software to
send software updates to multiple users in the campus simultaneously in one stream of data.
Many corporations and industries are now realizing the potential of multimedia applications.
Video and voice conferencing applications generate much of the multicast traffic today. Many
websites offer video streams that transmit multicast traffic. Companies are experiencing a
marked increase in multicast traffic from internal users. Because of the proliferation of multi-
cast applications, network administrators are charged with installing and configuring devices
and implementing policy to manage traffic associated with these applications. Many network
designs deal efficiently with unicast traffic but neglect the impact of multicast traffic within
the network. Unfortunately, this can severely affect a well-designed unicast network.
Again, it should be reiterated that it is critical in network design to take a proactive approach
to controlling multicast traffic in the network. The default behavior of a switch is to flood
multicast frames out all ports except the originating port. This is usually not the desired
effect. Cisco has implemented the proprietary Cisco Group Management Protocol (CGMP)
1439_CCNP_3.book Page 407 Wednesday, October 27, 2004 9:54 AM

Examining Multicast in a Multilayer Switched Network 407

and the nonproprietary Internet Group Management Protocol (IGMP) snooping to help
administer multicast traffic in the network. CGMP and IGMP snooping run on switches and
routers and work hand-in-hand with IGMP, running on routers, to control the flooding of
multicast traffic in a network. To control multicast traffic, either CGMP or IGMP snooping
would be used, but not both.
Multicast traffic originates at sources that need to distribute the same information to multiple
recipients, as illustrated in Figure 7-21.

Figure 7-21 Using Multicast Technology Greatly Reduces Unnecessary Replication of Data Traffic

Without Multicast

Network

Server Clients

With Multicast

Network

Server Clients

When a source creates multicast traffic, it uses special Layer 2 and Layer 3 addresses so that
routers and switches know how to route or switch the frame. By default, routers do not for-
ward multicast traffic unless they are multicast-capable and have a multicast routing protocol,
such as Distance Vector Multicast Routing Protocol (DVMRP) or Protocol-Independent
Multicast (PIM) enabled. DVMRP and PIM are interrouter protocols. Therefore, hosts and
switches do not participate in messages for these protocols.
By default, a switch floods multicast traffic within a broadcast domain. This consumes band-
width on both access links and trunk links. Depending on the host TCP/IP stack implementa-
tion and network interface card (NIC) attributes, the multicast frame can cause a CPU interrupt.
The reason a switch floods multicast traffic is that it has no entry in the bridge table for the des-
tination address. Multicast addresses never appear as source addresses. Therefore, the bridge/
switch cannot dynamically learn multicast addresses; they must be manually configured.
IGMP is a multicast protocol that directly affects hosts. IGMP allows hosts to inform routers
that they want to receive multicast traffic for a specific multicast group address.
1439_CCNP_3.book Page 408 Wednesday, October 27, 2004 9:54 AM

408 Chapter 7: Cisco AVVID

Many older switches don’t understand IGMP messages. As a result, Cisco developed the pro-
prietary CGMP, which lets routers inform switches about hosts and their interest in receiving
multicast traffic. This modifies the Catalyst switch default behavior of flooding the multicast
frame to all hosts in the broadcast domain. Rather than flooding the frame to all hosts, the
Catalyst switch limits the flooding scope to hosts in the broadcast domain that registered with
the router through IGMP. If a host does not register with the router, it does not receive a copy
of the multicast frame. This helps preserve access-link bandwidth.
Newer switches understand IGMP requests from hosts and implement IGMP snooping. IGMP
snooping constrains the flooding of multicast traffic by dynamically configuring the inter-
faces so that multicast traffic is forwarded only to interfaces associated with IP multicast
devices. The LAN switch snoops on the IGMP traffic between the host and the router and
keeps track of multicast groups and member ports. When the switch receives an IGMP join
report from a host for a particular multicast group, the switch adds the host port number to the
associated multicast forwarding table entry. When the switch receives an IGMP leave group
message from a host, the switch removes the host port from the table entry. After the switch
relays the IGMP queries from the multicast router, the switch deletes entries periodically if it
does not receive any IGMP membership reports from the multicast clients.

Multicast Addressing
Whenever an application needs to send data to more than one station but wants to restrict
the distribution to stations interested in receiving the traffic, the application typically uses a
multicast destination address. Whereas a broadcast targets all users in a domain, multicast
addresses target a select group of stations in the network, as shown in Figure 7-22. On the
other hand, if the source transmits unicast frames, it has to send multiple copies of the frame,
one addressed to each intended receiver. This is a very inefficient use of network resources
and does not scale well as the number of receivers increases. The disadvantage of broadcasts,
on the other hand, is that even if a host is not interested in receiving the broadcast, it still has
to process each frame.
By using multicast addresses, the source transmits only one copy of the frame onto the net-
work, and routers distribute the multicast message to the other segments where interested
receivers reside. As discussed previously, multicast addresses appear at Layer 2 and Layer 3.
A network administrator assigns the multicast Layer 3 address for an application. The Layer 2
multicast address is then calculated from the Layer 3 multicast address. When configuring a
multicast application, the NIC adds the multicast address to its list of valid Media Access
Control (MAC) addresses. Usually this list consists of the built-in MAC address plus any
user-configured addresses. Whenever the station receives a frame with a matching multicast
destination address, the receiver sends the frame to the CPU.
1439_CCNP_3.book Page 409 Wednesday, October 27, 2004 9:54 AM

Examining Multicast in a Multilayer Switched Network 409

Figure 7-22 A Multicast Server Sends a Single Data Stream to Multiple Clients Using a Special
Destination Address

1.5 Mb
Video
Server

1.5 Mb 1.5 Mb

1.5 Mb 1.5 Mb 1.5 Mb

Receiver Receiver Receiver Not A


Receiver

Layer 3 Multicast Addressing


IP multicast addresses at Layer 3 are characterized as Class D addresses. The first 4 bits of IP
Class D addresses are 1110. This means that IP multicast addresses have a valid range from
224.0.0.0 to 239.255.255.255. Note that multicast addresses from 224.0.0.0 to 224.0.0.255
are reserved. The following reserved addresses are specifically relevant to multicasting:
■ 224.0.0.1—All multicast-capable hosts on the segment
■ 224.0.0.2—All multicast-capable routers on the segment
■ 224.0.0.4—All DVMRP routers on the segment
■ 224.0.0.5—All Open Shortest Path First (OSPF) routers
■ 224.0.0.6—All OSPF designated routers
■ 224.0.0.9—All Routing Information Protocol version 2 (RIPv2) routers
■ 224.0.0.10—All Enhanced Interior Gateway Routing Protocol (EIGRP) routers
■ 224.0.0.13—All PIM routers
Usually, a network administrator assigns a multicast address to the application and must
select an address not used by other applications or processes. The administrator should not
use a multicast address in the reserved range.
1439_CCNP_3.book Page 410 Wednesday, October 27, 2004 9:54 AM

410 Chapter 7: Cisco AVVID

The IP multicast address space is subdivided into several formal categories. These include
reserved link local addresses, globally scoped addresses, limited scope addresses, and GLOP
addressing. The following sections address each of these categories in greater detail.

Reserved Link Local Addresses


The Internet Assigned Numbers Authority (IANA) has reserved addresses from 224.0.0.0 to
224.0.0.255 to be used by network protocols on a local network segment:
■ 224.0.0.1—All systems on this subnet
■ 224.0.0.2—All routers on this subnet
■ 224.0.0.5—OSPF routers
■ 224.0.0.6—OSPF designated routers
■ 224.0.0.9—RIPv2 routers
■ 224.0.0.10—EIGRP routers
■ 224.0.0.12—Dynamic Host Configuration Protocol (DHCP) server/relay agent
■ 224.0.0.13—All PIM routers
■ 224.0.0.22—IGMP
■ 224.0.0.25—Router-to-switch (such as Router-Port Group Management Protocol
[RGMP])
Packets with these link local addresses should never be forwarded by a router. They must
remain local on a particular LAN segment and are always transmitted with a time-to-live of 1.
Network protocols use these addresses for automatic router discovery and to communicate
important routing information. For example, OSPF uses 224.0.0.5 and 224.0.0.6 to exchange
link state information.

Globally Scoped Addresses


The address range from 224.0.1.0 to 238.255.255.255 is known as globally scoped addresses.
This range can be used to multicast data between organizations and across the Internet.
Some of these addresses have been reserved for use by multicast applications through IANA.
For example, 224.0.1.1 has been reserved for Network Time Protocol (NTP), used to syn-
chronize clocks on network devices. The IANA also assigned the two group addresses
224.0.1.39 and 224.0.1.40 for Auto-RP, a PIM sparse-mode mechanism that is discussed in
the section “Configure Auto-RP (Optional).”
1439_CCNP_3.book Page 411 Wednesday, October 27, 2004 9:54 AM

Examining Multicast in a Multilayer Switched Network 411

Limited Scope Addresses


The addresses in the range of 239.0.0.0 to 239.255.255.255 are known as limited scope
addresses or administratively scoped addresses. These are defined by RFC 2365 to be con-
strained to a local group or organization. Routers are typically configured with filters to pre-
vent multicast traffic in this address range from flowing outside an autonomous system (AS)
or any user-defined domain. Within an autonomous system or domain, the limited scope
address range can be further subdivided so that local multicast boundaries can be defined.
This subdivision also allows for address reuse between these smaller domains.

GLOP Addressing
RFC 2770 proposes that the 233.0.0.0/8 address range be reserved for statically defined
addresses, called GLOP addresses, by organizations that already have an AS number
reserved. The term GLOP was coined by the RFC’s author and is not an acronym. The
domain’s AS number is embedded in the second and third octets of the 233.0.0.0/8 range.
For example, AS 62010 is written in hex as F23A. Separating the two octets F2 and 3A
results in 242 and 58 in decimal. This provides for a subnet of 233.242.58.0 that would be
globally reserved for AS 62010 to use.

Layer 2 Multicast Addressing


When a Layer 3 multicast address is assigned, a Layer 2 address is automatically generated
from the IP address. To calculate the Layer 2 address, the host copies the last 23 bits of the IP
address into the last 24 bits of the MAC address. The high-order bit is set to 0.
The first 3 bytes (24 bits) of the multicast MAC address are 0x01-00-5E. This is a reserved
value that indicates a multicast application. More generally, any Ethernet multicast or broad-
cast frame has a 1 in the last bit of the first octet.
Consider the following example:
The IP address 224.1.10.10, assigned by an administrator, has a low 23-bit value of 1.10.10. In
hexadecimal format, this is 0x01-0A-0A. The MAC address takes the last 23 of the 24 bits and
places them in the MAC field. The complete MAC address in this case is 01-00-5E-01-0A-0A.
Figure 7-23 illustrates another example. In this case, the IP address 224.10.8.5 translates into
a MAC address of 01.00.5E.0A.08.05.
1439_CCNP_3.book Page 412 Wednesday, October 27, 2004 9:54 AM

412 Chapter 7: Cisco AVVID

Figure 7-23 Layer 3 Multicast Addresses Map to Layer 2 Multicast Addresses in a 32-to-1 Ratio

Multicast Address:
224 10 8 5

111 0 0 0 0 0 0 0 0 0 1 0 1 0 0 0 0 0 1 0 0 0 0 0 0 0 0 1 0 1

Ethernet Address:
01 00 5E 0A 08 05

0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 11 0 1111 0 0 0 0 0 1 0 1 0 0 0 0 0 1 0 0 0 0 0 0 0 0 1 0 1

Interactive Media Activity Drag and Drop: Multicast Addressing


In this Interactive Media Activity, you gain familiarity with the key ranges of IP
multicast addresses and associated terminology.

IGMP
IGMP grew out of the Host Membership Protocol. The first version, IGMPv1, was defined in
RFC 1112. The most recent version, IGMPv2, was ratified in November 1997 as a standard
by the Internet Engineering Task Force (IETF) and is covered in RFC 2236.
IGMP messages are used primarily by multicast hosts to signal their local multicast router
when they want to join a specific multicast group and begin receiving group traffic, as shown
in Figure 7-24. Hosts can also (with IGMPv2) signal to the local multicast router that they
want to leave an IP multicast group and are no longer interested in receiving multicast group
traffic.
Using information obtained through IGMP, routers maintain a list of multicast group mem-
berships on a per-interface basis. A multicast group membership is active on an interface if at
least one host on that interface has signaled its desire, using IGMP, to receive the multicast
group traffic.

IGMP Version 1
IGMP Version 1 (IGMPv1) messages are transported within IP datagrams to transmit infor-
mation about multicast groups. The datagram consists of a 20-byte IP header and an 8-byte
IGMP message (see Figure 7-25).
1439_CCNP_3.book Page 413 Wednesday, October 27, 2004 9:54 AM

Examining Multicast in a Multilayer Switched Network 413

Figure 7-24 IGMP Allows Hosts to Interactively Subscribe to and Leave IP Multicast Groups

Multicast
Source

Does Anyone Still


Want to Receive
Multicast Traffic?

Host Host
Membership Membership
Report Query

I Want to
Receive Multicast
Traffic for Group
239.225.160.171

Figure 7-25 IGMP Version 1 Messages Include a Message Type Field

0 3 7 15 31
IGMP
IGMP
Message Unused 16-Bit Checksum
Version
Type

IP Multicast Group Address

The first field of the message, IGMP Version, indicates what version of IGMP generated the
message. For Version 1, this value must be 1. The IGMP Message Type field specifies the
message type. Version 1 defines two messages:
■ A host membership query
■ A host membership report
The Checksum field carries the checksum computed by the source; the source computes the
checksum for the entire IGMP message. The receiving device examines the checksum value
to determine if the message was corrupted during transmission. If the checksum value doesn’t
1439_CCNP_3.book Page 414 Wednesday, October 27, 2004 9:54 AM

414 Chapter 7: Cisco AVVID

match, the receiver discards the message. Finally, the IP Multicast Group Address field indi-
cates the multicast destination group address targeted by the message.
When a host on the segment wants to receive multicast traffic, it issues an unsolicited host
membership report targeting the intended multicast group.
The destination MAC address targets the multicast group it intends to join. If this were the
only information in the frame to identify the group, any of 32 groups might be desired
because of the address ambiguity discussed earlier. However, the Layer 3 address is included
in both the IP header and the IGMP header. The Layer 3 multicast group desired by the host
is 239.255.160.171; this Layer 3 multicast address is equivalent to the 32 Layer 3 multicast
addresses in the ranges 224 to 239.255.160.171 and 224 to 239.127.160.171. This translates
to a MAC address of 01-00-5E-7F-A0-AB. All multicast-capable devices on the shared
media receive the membership report. In this situation, however, only the router is interested
in the frame. The frame tells the router, “I want to receive any messages for this multicast
group.” The router now knows that it needs to forward a copy of any frames with this multi-
cast address to the segment where the host that issued the report lives.
A device issues an IGMP membership report under two conditions:
■ Whenever the device first intends to receive a multicast stream—When enabling
the multicast application, the device configures the NIC, and the built-in IGMP pro-
cesses send an unsolicited membership report to the router, requesting copies of the
multicast frames.
■ In response to an IGMP membership query from the router—This is a solicited
membership report that helps the router confirm that hosts on the segment still want
to receive multicast traffic for a particular multicast group.
Routers periodically issue host membership queries. The query period might be configured
from 0 seconds to a maximum of 65,535 seconds. The default is 60 seconds.
Only one router on each segment issues the membership query message. If the segment uses
IGMP Version 1, the designated router for the multicast routing protocol issues the query. If
the segment uses IGMP Version 2, the multicast router with the lowest IP address on the seg-
ment issues the queries.
The host membership query message targets the all-multicast-hosts address, 224.0.0.1, in the
Layer 3 address field. The Layer 2 address is 01-00-5E-00-00-01. The IGMP header uses a
group address of 0.0.0.0. This translates to a query for all multicast hosts on all groups on the
segment.
A host for each active multicast group must respond to this message. When multicast hosts
receive the host membership query, and if the host wants to continue receiving multicast
frames for a multicast group, the multicast host starts an internal random timer with an upper
1439_CCNP_3.book Page 415 Wednesday, October 27, 2004 9:54 AM

Examining Multicast in a Multilayer Switched Network 415

range of 10 seconds. The host waits for the timer to expire, and then it sends a membership
report for each multicast group it wants to continue receiving.
If another station sends a membership report before the local timer expires, the host cancels
the timer and suppresses the report. This behavior prevents a segment and router from experi-
encing host membership report floods. Only one station from each multicast group needs to
respond for each group on the segment.
If the router does not receive a membership report for a particular multicast group for three
query intervals, it assumes that no hosts remain that are interested in that group multicast
stream. The router stops forwarding the multicast packets for this group and tells upstream
routers to stop sending frames.
This process defines an implicit leave from the multicast group. No special leave mechanism
is defined in IGMPv1. Instead, IGMPv1 hosts leave the group passively, without any notifica-
tion to the router. A router learns that such a host is not interested in participating in a multi-
cast group if the host does not respond to repeated queries from the router relating to that group.

IGMP Version 2
Looking at the format of IGMP Version 2 (IGMPv2) messages in Figure 7-26, notice that the
IGMP Message Type field has been merged with the IGMPv1 Version field and now occupies
a full octet. The values assigned to the various message types have been chosen carefully to
provide backward compatibility with IGMPv1. Another field added to IGMPv2 that is not
found in IGMPv1 is Maximum Response Time.

Figure 7-26 IGMP Version 2 Messages Include a Maximum Response Time Field

0 7 15 31

IGMP Maximum
Response Time 16-Bit Checksum
Version

IP Multicast Group Address

IGMP Version 2 adds two messages not found in IGMPv1 to streamline the join and leave
process. RFC 2236 added a Version 2 membership report and a leave group message. The
complete list of messages now consists of the following:
■ 0x11—Membership query
■ 0x12—Version 1 membership report
■ 0x16—Version 2 membership report
■ 0x17—Leave group
1439_CCNP_3.book Page 416 Wednesday, October 27, 2004 9:54 AM

416 Chapter 7: Cisco AVVID

The membership query and Version 1 membership report carry over from IGMPv1. However,
the membership query can now target specific multicast groups. In Version 1, the query mes-
sage is a general query with the group address set to 0.0.0.0. All active groups respond to the
general query. Version 2 allows a multicast query router to target a specific multicast group. A
multicast host running Version 2 responds with a Version 2 membership report. Other multi-
cast groups ignore the group-specific query if it is not directed at their group. The group-
specific membership query works only for Version 2 systems.
If a Version 2 host leaves a multicast group, it sends an unsolicited leave group message to
inform the query router that it no longer wants to receive the multicast stream. The router
maintains a table of all hosts in the multicast group on the segment. If other hosts still want to
receive the multicast stream, the router continues to send the multicast frames onto the seg-
ment. However, if the membership report arrives from the last host on the segment for the
multicast group, the router terminates the multicast stream for that group.
In Figure 7-27, consider the multicast group shown. Hosts H2 and H3 are currently members
of multicast group 224.1.1.1, although Host H2 wants to leave the group.

Figure 7-27 Host 2 Announces Its Desire to Leave the Multicast Group

H1 H2 H3

Leave to
#1 224.0.0.2

Group Specific
Query to 224.1.1.1
#2

The sequence of events for Host H2 to leave the group is as follows:


1. Host H2 multicasts an IGMPv2 leave group message to the all-routes (224.0.0.2) multi-
cast group to inform all routers on the subnet that it is leaving the group.
2. The router hears the leave group message from Host H2. However, because routers
keep a list of only the group memberships that are active on a subnet, not individual
hosts that are members, the router sends a group-specific query to determine whether
any hosts remain for Group 224.1.1.1. Because this is a group-specific query, only
hosts that are members of the group respond.
1439_CCNP_3.book Page 417 Wednesday, October 27, 2004 9:54 AM

Examining Multicast in a Multilayer Switched Network 417

3. Host H3 is still a member of Group 224.1.1.1 and responds to the query with an IGMPv2
membership report to inform the routers on the subnet that a member of this group is
still present. Host H3 is now the last remaining member of the group.
4. If Host H3 decides to leave, Steps 1 and 2 are repeated. However, when the router
issues a group-specific query, no hosts respond. As a result, the router times out the
group and stops forwarding packets for the group onto the subnet.
If the router wants to confirm the need to send a stream, it can transmit a general or group-
specific query onto the segment. If the router does not receive any responses to a couple of
query messages, it assumes that no more hosts want to receive the multicast stream.
Another feature added to IGMPv2 is the multicast router’s ability to specify the hosts’
response timer range. Remember that when a host receives a membership query, the host
starts a random timer. The timer value is in the range of 0 to maximum response time, with
the maximum response time specified in the router query message. Version 2 limits the
timer’s upper range to a maximum of 25 seconds. The default in a router is 10 seconds.

IGMP Version 1 and Version 2 Interoperability


The first possible combination of versions might involve hosts with a mix of versions and a
Version 1 router, as shown in Figure 7-28. All IGMP operations in this scenario are driven by
the version that the query router uses. When such a combination exists, the hosts must use
Version 1 messages. The router does not understand Version 2 membership reports, nor does
it understand Version 2 leave messages.
A second case is when the router supports IGMPv2 but hosts use IGMPv1. Although the
router understands more message types than the hosts, it ultimately uses only Version 1 mes-
sages. When the Version 2 router receives the Version 1 membership report, it remembers that
they are present and uses only Version 1 membership queries. Version 1 queries use the group
address 0.0.0.0 and do not generate group-specific queries. If they generated group-specific
queries, the Version 1 hosts would not recognize the message and would not know how to
respond.
What if both Version 1 and Version 2 hosts are on the segment, with a Version 2 router? As
in the previous case, the router must remember that there are Version 1 hosts and, therefore,
must issue Version 1 membership queries. Additionally, if any of the Version 2 hosts send a
leave message, the router must ignore it. The router ignores the message because it must still
issue general queries in case a Version 1 member is still active on the segment.
1439_CCNP_3.book Page 418 Wednesday, October 27, 2004 9:54 AM

418 Chapter 7: Cisco AVVID

Figure 7-28 IGMP Version 2 Routers Can Operate with Both IGMP Version 1 and Version 2 Hosts

IGMP
Version 1

V1 V2 V1 V2
ALL Hosts Run IGMP Version 1

IGMP
Version 2

V1 V2 V1 V2
Hosts Run Either IGMP Version 1 or IGMP Version 2

If two routers attach to the segment where one supports Version 1 and the other Version 2, the
Version 2 router must be administratively configured as a Version 1 router. The Version 1
router has no way to detect the presence of the Version 2 router. Because the two versions use
different methods of selecting the query router, they might not reliably agree on the query
router.

IGMP Version 3
IGMP Version 3 (IGMPv3) is the next step in the evolution of IGMP. IGMPv3 adds support
for source filtering, which lets a multicast receiver host signal to a router the groups from
which it wants to receive multicast traffic, and from which sources this traffic is expected.
This membership information lets Cisco IOS software forward traffic from only sources from
which receivers requested the traffic. Among other things, this added feature can prevent
rogue multicast servers from monopolizing the bandwidth on a segment; receivers must spe-
cifically request the servers from which multicast traffic is desired. IGMPv3 helps conserve
bandwidth by allowing hosts to specify the sources of multicast traffic.
1439_CCNP_3.book Page 419 Wednesday, October 27, 2004 9:54 AM

Examining Multicast in a Multilayer Switched Network 419

IGMPv3 supports applications that explicitly signal sources from which they want to receive
traffic. With IGMPv3, receivers signal membership to a multicast host group in the following
two modes:
■ INCLUDE mode—In this mode, the receiver announces membership to a host group
and provides a list of source addresses (the INCLUDE list) from which it wants to
receive traffic.
■ EXCLUDE mode—In this mode, the receiver announces membership to a multicast
group and provides a list of source addresses (the EXCLUDE list) from which it does
not want to receive traffic. The host receives traffic only from sources whose IP
addresses are not listed in the EXCLUDE list. To receive traffic from all sources, which
is the behavior of IGMPv2, a host uses EXCLUDE mode membership with an empty
EXCLUDE list.
As shown in Figure 7-29, Host H1 wants to join group 224.1.1.1 but wants to receive traffic
only from Source 1.1.1.1. The IGMPv3 host can signal the designated router, R3, that it is
only interested in multicast traffic from Source 1.1.1.1 for Group 224.1.1.1. Router R3 could
then potentially “prune” the unwanted source, 2.2.2.2.

Figure 7-29 With IGMP Version 3, a Host Can Specify Which Source(s) It Wants to Receive
Multicast Traffic from for a Particular Multicast Group

Source = 1.1.1.1 Source = 2.2.2.2


Group = 224.1.1.1 Group = 224.1.1.1

H1 wants to
receive only S = R3
1.1.1.1 and no other.
With IGMPv3,
specific sources
can be joined. S = IGMPv3
1.1.1.1 in this case. Join: 224.1.1.1
Include: 1.1.1.1
H1 – Member of 224.1.1.1

IGMP Snooping
Layer 2 switches need some degree of multicast awareness to avoid flooding multicasts to all
switch ports. IGMP snooping requires the LAN switch to examine, or “snoop,” some Layer 3
information in the IGMP packets sent between the hosts and the router. When the switch
1439_CCNP_3.book Page 420 Wednesday, October 27, 2004 9:54 AM

420 Chapter 7: Cisco AVVID

hears the IGMP host report from a host for a particular multicast group, it adds the host’s port
number to the associated multicast table entry. When the switch hears the IGMP leave group
message from a host, it removes the host’s port from the table entry.
When IGMP snooping is enabled, the switch responds to periodic multicast router queries to
all virtual LANs (VLANs) with only one join request per MAC multicast group. Also, the
switch creates one entry per VLAN in the Layer 2 forwarding table for each MAC multicast
group for which it receives an IGMP join request. All hosts interested in this multicast traffic
send join requests and are added to the forwarding table entry.
Because IGMP control messages are transmitted as multicast packets, they are indistinguish-
able from multicast data at Layer 2. A switch running IGMP snooping must examine every
multicast data packet to check if it contains any pertinent IGMP control information. Enabling
IGMP snooping on a low-end switch could severely affect performance when data is trans-
mitted at high rates. Figure 7-30 shows the processes required on switches using IGMP
snooping. CGMP, discussed later in this chapter, is an ideal alternative for low-end legacy
switches.

Figure 7-30 IGMP Snooping Is Now the Preferred Mechanism to Avoid Unnecessary Flooding to
All Switch Ports

PIM

Requirements and processes related to IGMP snooping are as follows:


■ Switches become IGMP-aware
■ IGMP packets are intercepted by the Network Management Processor (NMP) or by
special hardware ASICs
■ The switch must examine the contents of IGMP messages to determine which ports
want what traffic:
— IGMP membership reports
— IGMP leave messages
■ Impact on the switch:
— It must process all Layer 2 multicast packets.
— The administrative load increases with the multicast traffic load.
— It requires special hardware to maintain throughput.
1439_CCNP_3.book Page 421 Wednesday, October 27, 2004 9:54 AM

Examining Multicast in a Multilayer Switched Network 421

Configuring IGMP Snooping on a Catalyst IOS-Based Switch


By default, IGMP snooping is globally enabled. When it is globally enabled or disabled, it
is also enabled or disabled in all existing VLAN interfaces. By default, IGMP snooping is
enabled on all VLANs, but it can be enabled and disabled on a per-VLAN basis.
If IGMP global snooping is disabled, VLAN snooping might not be enabled. If global IGMP
snooping is enabled, snooping might be enabled or disabled on a VLAN basis.
To globally enable IGMP snooping, enter the global configuration command ip igmp snoop-
ing. The global command no ip igmp snooping vlan vlan-id disables IGMP snooping on a
particular VLAN.
To specify the next-hop interface to the multicast router, use the global configuration com-
mand ip igmp snooping vlan vlan-id mrouter interface interface-id.
When IGMP immediate-leave processing is enabled, the switch immediately removes a port
from the IP multicast group when it detects an IGMPv2 leave message on that port. Immedi-
ate-leave processing allows the switch to remove an interface from the forwarding table after
receiving a leave message without first sending group-specific queries from the interface. The
immediate-leave feature should be implemented only when a single receiver is present on
every port in the VLAN. The immediate-leave feature is disabled by default. Use the ip igmp
snooping vlan vlan-id immediate-leave global configuration command to enable IGMP
immediate-leave processing on a VLAN interface.
Example 7-1 shows a sample configuration for IGMP snooping.

Example 7-1 IGMP Snooping Can Be Configured on Catalyst 2950, 3550, 4500, and 6500 Switches

Switch(config)#ip igmp snooping


Switch(config)#ip igmp snooping vlan 1 immediate-leave
Switch(config)#ip igmp snooping vlan 2 immediate-leave
Switch(config)#exit
Switch#show ip igmp snooping

vlan 1
----------
IGMP snooping is globally enabled
IGMP snooping is enabled on this vlan
IGMP snooping immediate-leave is enabled on this vlan
IGMP snooping mrouter learn mode is pim-dvmrp on this vlan

continues
1439_CCNP_3.book Page 422 Wednesday, October 27, 2004 9:54 AM

422 Chapter 7: Cisco AVVID

Example 7-1 IGMP Snooping Can Be Configured on Catalyst 2950, 3550, 4500, and 6500 Switches (Continued)

vlan 2
----------
IGMP snooping is globally enabled
IGMP snooping is enabled on this vlan
IGMP snooping immediate-leave is enabled on this vlan
IGMP snooping mrouter learn mode is cgmp on this vlan
vlan 3
----------
IGMP snooping is globally enabled
IGMP snooping is enabled on this vlan
IGMP snooping immediate-leave is disabled on this vlan
IGMP snooping mrouter learn mode is cgmp on this vlan

The switch might be configured to either snoop on Protocol-Independent Multicast/Distance


Vector Multicast Routing Protocol (PIM/DVMRP) packets or to listen to CGMP self-join
packets. By default, the switch snoops on PIM/DVMRP packets on all VLANs. PIM and
DVMRP are discussed later in this chapter.
To learn of multicast router ports through only CGMP self-join packets, use the following
global configuration command:
Switch(config)#ip igmp snooping vlan vlan-id mrouter learn cgmp

When this command is used, the router listens only to CGMP self-join packets and no other
CGMP packets.
To learn of multicast router ports through only PIM/DVMRP packets, use the following
global configuration command:
Switch(config)#ip igmp snooping vlan vlan-id mrouter learn pim-dvmrp

To view the Layer 2 multicast entries for the switch or for a VLAN, use the following
command:
Switch#show mac-address-table multicast [vlan vlan-id] [user | igmp-snooping]
[count]

The user option displays only the user-configured multicast entries.

CGMP Operation
CGMP is a Cisco-proprietary protocol that allows switches to learn about the existence of
multicast clients from Cisco routers and older IOS-based switches. CGMP is based on a
client/server model. The router is considered a CGMP server, with the switch taking on
1439_CCNP_3.book Page 423 Wednesday, October 27, 2004 9:54 AM

Examining Multicast in a Multilayer Switched Network 423

the client role. The basis of CGMP is that the IP multicast router sees all IGMP packets
and, therefore, can inform the switch when specific hosts join or leave multicast groups. The
switch then uses this information to construct a forwarding table.
When the router sees an IGMP control packet, it creates a CGMP packet. This CGMP packet
contains the request type, a join or a leave, the multicast group address, and the client’s MAC
address. The packet is sent to a well-known address to which all switches listen. Each switch
then interprets the packet and creates the proper entries in a forwarding table, as illustrated in
Figure 7-31.

Figure 7-31 CGMP Is Used on Older Catalyst Switches, Such as the Catalyst 1900, 2820, 2900XL,
3500XL, and 5000

Device
0000.0c12.3456
wants to join
I can reach device Group 234.10.8.5.
0000.0c12.3456 out of Port 1.
I will add 234.10.8.5 to
my switch forwarding table.
I have no
CG
ge

knowledge of
M
sa

P
es

device
M
M

es
P

0000.0c12.3456.
sa
M

ge
CG

0000.0c12.3456

CGMP can run on an interface only if PIM is configured on the same interface. CGMP is dis-
abled on a router by default. To enable CGMP on the router, enter the ip cgmp command in
interface configuration mode. This command enables the CGMP for IP multicasting on a
router and triggers a CGMP join message. The running configuration indicates if a specific
router interface has been configured for CGMP.
For CGMP to operate correctly on a switch, the switch must have a network connection to a
router running CGMP. A CGMP-capable IP multicast router detects all IGMP packets and
informs the switch when specific hosts join or leave IP multicast groups. When the CGMP-
capable router receives an IGMP control packet, it creates a CGMP packet that contains
the request type, the multicast group address, and the host’s MAC address. The router then
sends the CGMP packet to a well-known address to which switches listen, as illustrated in
1439_CCNP_3.book Page 424 Wednesday, October 27, 2004 9:54 AM

424 Chapter 7: Cisco AVVID

Figure 7-32. CGMP is no longer supported on the new series of Catalyst switches, including
the 2950 and 3550 series. IGMP snooping has replaced CGMP on these models.

Figure 7-32 CGMP Frames Are Sent to a Well-Known Multicast Address

CGMP
Commands
PIM
IGMP

Requirements and processes related to CGMP are as follows:


■ CGMP runs on both the switches and the router.
■ The router sends CGMP multicast packets to the switches at a well-known multicast
MAC address: 0100.0cdd.dddd.
■ The CGMP packet contains the following:
— Type field (join or leave)
— MAC address of the IGMP client
— Multicast address of the group
■ The switch uses CGMP packet information to add or remove an entry for a particular
multicast MAC address.

Routing Multicast Traffic


The campus network is composed of a collection of subnetworks connected by routers. When
the source of a video data stream is located on one subnet and the host devices are located on
different subnets, there needs to be a way of determining how to get from the source to the
destinations. This is the function of IP.
Each host on the Internet has an IP address that identifies the host’s location. Part of the
address identifies the subnet on which the host resides and part identifies the individual host
on that subnet. Routers periodically send routing update messages to adjacent routers, con-
veying the network’s state as perceived by that particular router. This data is recorded in rout-
ing tables that are then used to determine optimal transmission paths for forwarding messages
across the network.
Unicast transmission involves transmission from a single source to a single destination. The
transmission is directed toward a single physical location that is specified by the host address.
This routing procedure is relatively straightforward because of the binding of a single address
to a single host.
1439_CCNP_3.book Page 425 Wednesday, October 27, 2004 9:54 AM

Routing Multicast Traffic 425

Routing multicast traffic is a more complex problem. A multicast address identifies a particu-
lar transmission session, rather than a specific physical destination. An individual host can
join an ongoing multicast session by using IGMP to communicate this desire to the subnet
router, as illustrated in Figure 7-33.

Figure 7-33 Multicast Transmissions Are Particularly Useful with IP Video Transmissions

Unicast Multicast

Video Server Video Server

100 Copies 1 Copy

Switch Switch

100 Copies 1 Copy

Router Router

33 Copies 33 34 Copies 1 Copy 1 1 Copy


Copies Copy

Router Router

33 Copies 33 Copies 34 Copies 1 Copy 1 Copy 1 Copy

Switch Switch
33 Clients 33 Clients 34 Clients 33 Clients 33 Clients 34 Clients

Because the number of receivers for a multicast session can potentially be quite large, the
source should not need to know all the relevant addresses. Instead, the network routers must
somehow be able to translate multicast addresses into host addresses. The basic principle
involved in multicast routing is that routers interact with each other to exchange information
about neighboring routers.

Distribution Trees
To deliver multicast packets to all receivers, designated routers construct a tree that connects
all members of an IP multicast group. A distribution tree specifies a unique forwarding path
between the subnet of the source and each subnet containing members of the multicast group.
A distribution tree has just enough connectivity so that there is only one, loop-free path
between every pair of routers. Because each router knows which of its lines belong to the
tree, it can copy an incoming multicast datagram onto all the outgoing branches. This action
generates the minimum needed number of datagram copies. Because messages are replicated
1439_CCNP_3.book Page 426 Wednesday, October 27, 2004 9:54 AM

426 Chapter 7: Cisco AVVID

only when the tree branches, the number of copies of the messages transmitted through the
network is minimized.
Because multicast groups are dynamic, with members joining or leaving a group at any time,
the distribution tree must be dynamically updated. Branches that contain new members must
be added. Branches in which no listeners exist must be discarded, or pruned.
As Figure 7-34 illustrates, there are two basic tree construction techniques:
■ Source-specific trees
■ Shared or center-specific trees

Figure 7-34 Source Distribution Trees and Shared Distribution Trees Are Used with IP
Multicast Routing

Source

Source Tree
Shared Tree
(Shortest
from RP
Path Tree)

Receiver

Source Distribution Tree


The simplest form of a multicast distribution tree is a source tree, whose root is the source
of the multicast traffic and whose branches form a spanning tree through the network to the
receivers. Because this tree uses the shortest path through the network, it is also often called
a shortest-path tree (SPT).
Figure 7-35 shows an example of an SPT for Group 224.1.1.1 rooted at the source, Host A,
and connecting two receivers, Hosts B and C.
The special notation of (S,G), pronounced “S comma G,” enumerates an SPT, where S is the
IP address of the source and G is the multicast group address. Using this special notation,
the SPT in Figure 7-35 would be written as (192.1.1.1, 224.1.1.1). The (S,G) entries are
stored on the multicast routers.
1439_CCNP_3.book Page 427 Wednesday, October 27, 2004 9:54 AM

Routing Multicast Traffic 427

Figure 7-35 Source Distribution Trees Are Indicated with the (S,G) Notation

Host
Source
A

192.1.1.1 Notation: (S, G)


S = Source
G = Group

A B D F
224.1.1.1 Traffic

C E

192.2.2.2 192.3.3.3

Receiver Host Host


Receiver
B C

Notice that this notation implies that a separate SPT exists for every individual source origi-
nating a stream for a multicast group. Therefore, if Host B is also sending traffic to Group
224.1.1.1 and Hosts A and C are receivers, a separate (S,G) SPT would exist with a notation
of (192.2.2.2, 224.1.1.1).

Shared Distribution Tree


Unlike source trees, which have their roots at the source, shared trees use a single common
root placed at some chosen point in the network. Depending on the multicast routing proto-
col, this root is often called a rendezvous point (RP) or core, which lends itself to other com-
mon names of shared trees: RP Trees (RPT) or Core-Based Trees (CBT).
Figure 7-36 shows a shared tree for Group 224.2.2.2 with the root located at Router D. When
using a shared tree, sources must send their traffic to the root for the traffic to reach all
receivers.
In this example, multicast group traffic from source Host A and Host D travels to the root
(Router D) and then down the shared tree to two receivers, Hosts B and Host C. Because all
sources in the multicast group use a common shared tree, a wildcard notation written as
(*,G), pronounced “star comma G,” represents the tree. In this case, * means all sources, and
G represents the multicast group. Therefore, the shared tree shown in Figure 7-36 would be
written (*,224.2.2.2). The (*,G) entries are stored on the multicast routers.
1439_CCNP_3.book Page 428 Wednesday, October 27, 2004 9:54 AM

428 Chapter 7: Cisco AVVID

Figure 7-36 Shared Distribution Trees Are Indicated with the (*,G) Notation

Host
Source
A

192.1.1.1 Notation: (*, G)


* = Source
G = Group
Source 2

Host
A B D F D
224.2.2.2 Traffic
(Shared Root)

C E

192.2.2.2 192.3.3.3

Receiver Host Host


Receiver
B C

Managing Delivery of Multicast Packets


In a campus network, limiting high-bandwidth traffic to specific LANs or regions within the
network is essential to containing or eliminating unnecessary consumption of resources. One
method of containing multicast traffic is to impose constraints on the forwarding of that traf-
fic by using the Time-To-Live (TTL) field in the IP packet.
As in unicast routing, the multicast TTL field controls the packet’s lifetime. The function of
TTL is to prevent packets from being looped forever because of routing errors. However, the
TTL field in multicasting also carries the concept of a “threshold.”
Multicast-enabled routers have a TTL threshold assigned to each interface. Packets with a
TTL greater than the interface threshold are forwarded, and packets with a TTL equal to
or less than the interface threshold are discarded. The packet TTL is compared to the inter-
face threshold first. The router then decrements the packet TTL by a value of 1 as the packet
is sent out the interface (see Figure 7-37).
A multicast packet with a TTL of less than 16 is restricted to the same department, or site,
and should not be forwarded across an interface to other sites in the same region. Defining the
scope of a “site” or “region” is the responsibility of the network administrator.
1439_CCNP_3.book Page 429 Wednesday, October 27, 2004 9:54 AM

Routing Multicast Traffic 429

Figure 7-37 Assigning a TTL Threshold to Each Interface Limits the Scope of Multicast
Transmission

ACME Manufacturing, Inc.

Human Resources

Personnel Payroll Engineering

TTL Threshold = 15

TTL Threshold = 31

TTL Threshold = 127

Assigning a TTL Threshold to Each Interface Limits the Scope of


Multicast Transmission

A multicast router forwards a multicast packet across an interface only if the TTL field in
the IP header is greater than the TTL threshold assigned to the interface. If the TTL field in the
packet’s IP header is equal to or less than the TTL threshold assigned to the interface, the packet is
discarded. If the interface has no assigned TTL threshold, the packet is forwarded.
In Figure 7-38, the interfaces on the router have been configured with the following TTL
thresholds:
■ E1—TTL Threshold = 16
■ E2—TTL Threshold = 0 (none)
■ E3—TTL Threshold = 64
An incoming multicast packet for Group XYZ is received on Interface E0 with a TTL of 24.
The outgoing interface list for Group XYZ contains Interfaces E1, E2, and E3. The TTL
threshold check is performed on each outgoing interface as follows:
■ E1—TTL (24) > TTL Threshold (16). FORWARD
■ E2—TTL (24) > TTL Threshold (0). FORWARD
■ E3—TTL (24) < TTL Threshold (64). DROP
The TTL is then decremented to 23 by normal router IP packet processing.
1439_CCNP_3.book Page 430 Wednesday, October 27, 2004 9:54 AM

430 Chapter 7: Cisco AVVID

Figure 7-38 Distinct TTL Thresholds Can Be Configured on Independent Interfaces

Multicast Packet Group


w/TTL = 24 XYZ

E0
E1
E3
E2

E1: (TTL Threshold = 16)


E2: (TTL Threshold = 0)
E3: (TTL Threshold = 64)

Reverse Path Forwarding (RPF)


Reverse Path Forwarding (RPF) is a fundamental concept in multicast routing that lets rout-
ers correctly forward multicast traffic down the distribution tree. RPF uses the existing uni-
cast routing table to determine the upstream and downstream neighbors. A router forwards a
multicast packet only if it is received on the upstream interface. This RPF check helps guar-
antee that the distribution tree is loop-free.

RPF Check
When a multicast packet arrives at a router, the router performs an RPF check on the packet.
If the RPF check is successful, the packet is forwarded. Otherwise, it is dropped.
For traffic flowing down a source tree, the RPF check procedure works as follows:
1. The router looks up the source address in the unicast routing table to determine if it has
arrived on the interface that is on the reverse path back to the source.
2. If the packet has arrived on the interface leading back to the source, the RPF check is
successful, and the packet is forwarded.
3. If the RPF check in Step 2 fails, the packet is dropped.

Figure 7-39 shows an example of an unsuccessful RPF check.


1439_CCNP_3.book Page 431 Wednesday, October 27, 2004 9:54 AM

Routing Multicast Traffic 431

Figure 7-39 Packets That Fail the RPF Check Are Discarded

Multicast Packet from


Source 151.10.3.21

S0
S1 S2

E0
Packet Arrived on
Wrong Interface!
Discard Packet
Multicast Route Table
Network Interface
151.10.0.0/16 S1
198.14.32.0/24 S0
204.1.16.0/24 E0

A multicast packet from source 151.10.3.21 is received on interface S0. A check of the uni-
cast route table shows that the interface this router would use to forward unicast data to
151.10.3.21 is S1. Because the packet arrives on S0, it is discarded.
Figure 7-40 is an example of a successful RPF check.

Figure 7-40 Packets That Pass the RPF Check Are Forwarded

Multicast Packet from


Source 151.10.3.21

S0
S1 S2

E0

Packet Arrived on
Correct Interface!
Multicast Route Table
Network Interface
151.10.0.0/16 S1
198.14.32.0/24 S0
204.1.16.0/24 E0
1439_CCNP_3.book Page 432 Wednesday, October 27, 2004 9:54 AM

432 Chapter 7: Cisco AVVID

This time the multicast packet arrives on S1. The router checks the unicast routing table and
finds that S1 is the correct interface.

Multicast Routing Protocols


A multicast routing protocol is responsible for constructing multicast delivery trees and
enabling multicast packet forwarding. Different IP multicast routing protocols use different
techniques to construct multicast spanning trees and forward packets.
IP multicast routing protocols generally follow one of two basic approaches, depending on
the distribution of multicast group members on the network:
■ Dense-mode routing protocols:
— DVMRP
— PIM Dense Mode (PIM-DM)
— Multicast Open Shortest Path First (MOSPF)
■ Sparse-mode routing protocols:
— CBT
— PIM Sparse Mode (PIM-SM)

Dense-Mode Routing Protocols


The dense-mode routing protocol approach is based on the assumption that the multicast
group members are densely distributed throughout the network and bandwidth is plentiful,
meaning that almost all hosts on the network belong to the group. These dense-mode multi-
cast routing protocols rely on periodic flooding of the network with multicast traffic to set up
and maintain the distribution tree.
To reiterate, dense-mode routing protocols include the following:
■ DVMRP
■ PIM-DM
■ MOSPF
Dense-mode protocols employ only SPTs to deliver (S,G) multicast traffic using a push prin-
ciple. The push principle assumes that every subnet in the network has at least one receiver of
the (S,G) multicast traffic, and, therefore, the traffic is pushed or flooded to all points in the
network. This process is analogous to a radio or TV broadcast that is transmitted over the air
to all homes within the coverage area. Receivers simply need to tune in to the broadcast to
receive the program.
The DM protocols are most appropriate in environments with densely clustered receivers and
the bandwidth to tolerate flooding. An example of when a DM protocol might be used is
1439_CCNP_3.book Page 433 Wednesday, October 27, 2004 9:54 AM

Routing Multicast Traffic 433

when a CEO of a company wants to broadcast a message to all employees within the head-
quarters campus network.

Distance Vector Multicast Routing Protocol


DVMRP was the first true multicast routing protocol to see widespread use. DVMRP is simi-
lar in many ways to Routing Information Protocol (RIP), with some variations added to sup-
port multicast. Described in RFC 1075, DVMRP is widely used on the Internet multicast
backbone (MBONE). The key characteristics of DVMRP are as follows:
■ Distance vector-based (similar to RIP)
■ Periodic route updates (every 60 seconds)
■ Infinity = 32 hops
■ Classless
DVMRP uses reverse-path flooding. When a router receives a packet, it floods the packet out
all paths except the one that leads back to the packet source. This technique allows a data
stream to reach all LANs. If a router is attached to a set of LANs that do not want to receive a
particular multicast group, the router can send a prune message back up the distribution tree
to stop subsequent packets from traveling where there are no members.
DVMRP periodically floods packets to reach any new hosts that want to receive traffic from a NOTE
particular multicast group. There is a direct relationship between the time it takes for a new Cisco routers run PIM.
They know enough
receiver to get the data stream and the frequency of flooding.
about DVMRP to suc-
DVMRP implements its own unicast routing protocol to determine which interface leads cessfully forward multi-
cast packets to and
back to the source of the data stream. This unicast routing protocol is similar to RIP and is receive packets from a
based purely on hop counts. As a result, the path that the multicast traffic follows might not DVMRP neighbor.
Cisco routers can also
be the same as the path that the unicast traffic follows. propagate DVMRP
routes into and through
a PIM cloud. However,
Protocol-Independent Multicast Dense Mode only the PIM protocol
Protocol-Independent Multicast (PIM) gets its name from the fact that it is IP routing proto- uses this information.
Cisco routers do not
col-independent. That is, regardless of which unicast routing protocol(s) is/are used to popu- implement DVMRP
late the unicast routing table (including static routes), PIM uses this information to perform to forward multicast
multicast forwarding; hence, it is protocol-independent. Although PIM is typically referred to packets.

as a multicast routing protocol, it actually uses the existing unicast routing table to perform
the RPF check function instead of maintaining a separate multicast route table. Because
PIM doesn’t have to maintain its own routing table, it doesn’t send or receive multicast route
updates like other protocols, such as MOSPF and DVMRP. By not having to send multicast
route updates, the PIM overhead is significantly reduced in comparison to other multi-
cast protocols.
1439_CCNP_3.book Page 434 Wednesday, October 27, 2004 9:54 AM

434 Chapter 7: Cisco AVVID

PIM-DM is similar to DVMRP, as you can see from the following list of key characteristics:
■ Protocol-independent (uses a unicast route table for RPF check)
■ No separate multicast routing protocol (as with DVMRP)
■ Flood-and-prune behavior (3-minute cycle)
■ Classless (as long as classless unicast routing is in use)
PIM-DM works best when numerous members belong to each multimedia group. PIM floods
the multimedia packet to all routers in the network and then prunes routers that do not support
members of that particular multicast group.
PIM-DM is most useful when
■ Senders and receivers are in close proximity to one another
■ There are few senders and many receivers
■ The volume of multicast traffic is high
■ The stream of multicast traffic is constant
PIM-DM is no longer a widely deployed protocol because PIM-SM has proven to be the
more efficient multicast solution.

Multicast Open Shortest Path First


NOTE Described in RFC 1584, Multicast Open Shortest Path First (MOSPF) is intended for use
Cisco routers do not within a single routing domain, such as a network controlled by a single organization.
support MOSPF.
MOSPF is dependent on the use of OSPF as the accompanying unicast routing protocol.
Figure 7-41 shows how MOSPF works by including multicast information in OSPF link-state
advertisements. An MOSPF router learns which multicast groups are active on which LANs.
MOSPF is best suited for environments that have relatively few (S,G) pairs active at any
given time. This protocol works less well in environments that have many active sources or
unstable links.

Sparse Mode Routing Protocols


The second approach to multicast routing is based on the assumption that the multicast group
members are sparsely distributed throughout the network and bandwidth is not necessarily
widely available.
It is important to note that sparse mode does not imply that the group has few members, just
that they are widely dispersed. In this case, flooding would unnecessarily waste network
bandwidth and could cause serious performance problems. Therefore, sparse-mode multicast
routing protocols must rely on more selective techniques to set up and maintain multicast
trees. Sparse-mode protocols begin with an empty distribution tree and add branches only as
the result of explicit requests to join the distribution.
1439_CCNP_3.book Page 435 Wednesday, October 27, 2004 9:54 AM

Routing Multicast Traffic 435

Figure 7-41 MOSPF Operation

OSPF Area
Member Member

N8 N9

X Y
Member
MOSPF MOSPF

N1 MOSPF

Member Source 2
N2 B
A N3
MOSPF MOSPF

D E F

MOSPF N4 MOSPF N5 MOSPF N6 MOSPF N7

Source 1 Source 1 Member Member

To reiterate, sparse-mode routing protocols include the following:


■ CBT
■ PIM-SM
Because sparse-mode protocols assume that relatively few routers in the network will be
involved in each multicast, these protocols are more appropriate in WAN environments.

Core-Based Trees
RFC 2201 describes CBT. The CBT protocol constructs a single tree that is shared by all
members of the group. Multicast traffic for the entire group is sent and received over the same
tree, regardless of the source. This use of a shared tree can provide significant savings in
terms of the amount of multicast state information that is stored in individual routers.
A CBT shared tree has a core router that is used to construct the tree, as shown in Figure 7-42.
Routers join the tree by sending a join message to the core. When the core receives a join
request, it returns an acknowledgment over the reverse path, thus forming a branch of the
tree. Join messages need not travel all the way to the core before being acknowledged. If a
1439_CCNP_3.book Page 436 Wednesday, October 27, 2004 9:54 AM

436 Chapter 7: Cisco AVVID

join message encounters a router on the tree before the message reaches the core, that router
terminates the join message and acknowledges it. The router that sent the join is then con-
nected to the shared tree.

Figure 7-42 The CBT Protocol Core Router Constructs a Single Tree Shared by All Members of
the Group

Source 1

Core
Router

Source 2

Join
Message

I have a member
Join who wants to join
Message Group XYZ.
I am already a
branch of that tree.
I will acknowledge
the join message.

The CBT multicast routing protocol is truly a work in progress and has been so for several
years. The original version, CBTv1, was superseded by CBTv2 (defined in RFC 2189),
which, unfortunately, is not backward-compatible with CBTv1. However, because CBTv1
was never really implemented in any production networks to speak of, backward compatibil-
ity is not an issue. CBTv2 also has not seen significant deployment to date, which is probably
good, because a new draft specification for CBTv3 is already out that supersedes and is not
backward-compatible with CBTv2!

PIM-SM
Protocol-Independent Multicast Sparse Mode (PIM-SM) is optimized for environments that
have many multipoint data streams. Sparse multicast is most useful when
■ A group has few receivers
■ The type of traffic is intermittent
1439_CCNP_3.book Page 437 Wednesday, October 27, 2004 9:54 AM

Routing Multicast Traffic 437

In sparse mode, each data stream goes to a relatively small number of segments in the campus
network. Instead of flooding the network to determine the status of multicast members, PIM-SM
defines a rendezvous point. When a sender wants to send data, it first sends to the rendezvous
point. When a receiver wants to receive data, it registers with the rendezvous point. When the
data stream begins to flow from sender to rendezvous point to receiver, the routers in the path
optimize the path automatically to remove any unnecessary hops. PIM-SM assumes that no
hosts want the multicast traffic unless they specifically ask for it. PIM can simultaneously
support dense mode for some multicast groups and sparse mode for others.

Configure IP Multicast Routing


The IP multicast routing tasks are divided into basic and advanced tasks. The basic tasks that
must be performed to set up a multicast session are as follows:
■ Enabling IP multicast routing
■ Enabling PIM on an interface
■ Configuring a rendezvous point (optional)
■ Configuring a TTL threshold (optional)
■ Joining a multicast group (optional)
■ Changing the IGMP version (optional)
■ Enabling CGMP or IGMP snooping (optional)
The first two basic tasks in the list are required to configure IP multicast routing; the remain-
ing tasks are optional.
NOTE
Configuring PIM-SM is really quite straightforward. On each router in the network, IP multi-
Another method of
cast routing must be enabled by using the ip multicast-routing global configuration com- enabling multicast on
mand, first introduced in Cisco IOS Release 10.1. an interface is the use
of the ip pim sparse-
Then, it is best to enable PIM-SM on every interface in every router in the network using the dense-mode command.
This command allows
ip pim sparse-mode interface command.
the router to use either
The final step is to configure each of the routers in the network with the RP’s IP address using dense or sparse mode,
depending on the exist-
the following global configuration command: ence of RP information
Router(config)#ip pim rp-address rp-address for each multicast
group. This makes it
This command tells the router where to send the (*,G) joins when it needs to join the shared much easier to switch
tree in sparse mode. the entire network from
dense mode to sparse
The reason for turning on multicast on every interface is that IP multicast routing is upside- mode (or vice versa) as
needed. PIM sparse-
down routing that forwards (or does not forward) multicast packets based on where the dense mode is the rec-
packets came from (source IP address) as opposed to where they are going (multicast group ommended mode to use
address). Consequently, the control mechanism for multicast traffic paths is not quite the when deploying Auto-
RP, as discussed later.
same as the control mechanism for unicast routing.
1439_CCNP_3.book Page 438 Wednesday, October 27, 2004 9:54 AM

438 Chapter 7: Cisco AVVID

Not turning on multicast routing on every interface is a common mistake when network
administrators are first enabling multicast routing. Failure to enable multicast on every inter-
face often results in RPF failures, because the RPF interface for a particular source of multi-
cast traffic is the interface that would be used if the router sent traffic to this particular source.

Verify PIM Configuration


To display information about interfaces configured for PIM, enter the show ip pim interface
[type number] [count] privileged mode command, as shown in Example 7-2.

Example 7-2 Displaying the IP Address of the Next-Hop Multicast Router, as Well as the Interface’s PIM Mode,
Can Be Useful

Router#show ip pim interface


Address Interface Version/Mode Nbr Query DR
Count Intvl
10.1.1.2 FastEthernet0/0 v2/Sparse-Dense 0 30 10.1.1.2
192.168.1.1 Serial0/0 v2/Sparse-Dense 0 30 0.0.0.0
0.0.0.0 Serial0/1 v2/Sparse-Dense 0 30 0.0.0.0
Router#

The output in Example 7-2 displays the following items:


■ The IP address of the next-hop router
■ The interface type; on a Route Switch Module (RSM), this value is the VLAN
designation
■ The PIM version and mode configured on each interface
■ How many PIM neighbors have been discovered through this interface
■ The frequency, in seconds, of PIM router-query messages
■ The IP address of the designated router on the LAN

Designated Router Selection


NOTE Cisco routers use the PIM routing protocol to forward multicast traffic. Two PIM routers are
DR election is neces- neighbors if there is a direct connection between them.
sary only on multi-
access networks. It is Each multicast-enabled router is configured to know which interfaces will use PIM. These
not required for point- interfaces connect either to neighboring PIM routers in the network or to host systems on a
to-point links, because
the connected router is LAN. If a LAN has multiple PIM routers, they are considered neighbors.
effectively the DR for
directly connected host The procedure for electing the designated router (DR) is the same for both PIM-SM and
systems. PIM-DM. Each PIM router connected to a multiaccess LAN issues periodic PIM router
1439_CCNP_3.book Page 439 Wednesday, October 27, 2004 9:54 AM

Routing Multicast Traffic 439

queries onto the LAN. The PIM router with the highest IP address becomes the DR for the
LAN. If the DR becomes inoperable, a new DR is elected from the alternate PIM routers on
the LAN. Figure 7-43 illustrates the DR election process.

Figure 7-43 PIM Elects a DR on a LAN

172.16.41.143 172.16.41.144
PIM Router 1 PIM Router 2
Highest IP Address
Elected as DR

PIM Query PIM Query

On a multiaccess LAN, one router is selected to poll the LAN for host group membership.
However, all PIM routers on a single subnet receive replies from the host. The router selected
to poll the LAN is called the DR. The DR is responsible for sending IGMP host-query mes-
sages to all hosts on the LAN. A campus network can have many DRs, one for each leaf sub-
net of the distribution tree.

Displaying PIM Neighbors


Cisco IOS software can be used to discover the PIM neighbors in the network. To display a
table of the neighboring routers from a specific router, enter this privileged mode command:
Router#show ip pim neighbor type number

Configure Auto-RP (Optional)


Manually configuring multiple rendezvous points in a large campus network can result in
inconsistent RP configurations and can cause connectivity problems. Auto-RP is a Cisco-pro-
prietary standalone protocol that automates the distribution of group-to-RP mappings in a
network running sparse-mode PIM. Auto-RP facilitates the use of multiple RPs within a net-
work to serve different group ranges. Auto-RP also allows load splitting among different RPs
and the arrangement of RPs according to the locations of group participants. With the Auto-
RP mechanism, an rp-announce command must be entered on the router to act as an RP for
a certain range of multicast group addresses. Multiple RPs can be used to serve different
group ranges, or to serve as backups of each other. An RP mapping agent is assigned to a
router to receive the RP announcement messages. The RP mapping agent then sends the
1439_CCNP_3.book Page 440 Wednesday, October 27, 2004 9:54 AM

440 Chapter 7: Cisco AVVID

consistent group-to-RP mappings to all designated routers. This method allows all designated
routers to automatically discover which RP to use for attached receivers and senders, as
shown in Figure 7-44.

Figure 7-44 Auto-RP Enables the Propagation of Group-to-RP Mappings

I would like
to be the RP
I would like for Group XYZ. Router A is the
to be the RP RP for Group ABC
for Group ABC. and Router B
Router B
is the RP for
Group XYZ.
Router A
RP Mapping Agent
Campus Network

Designated Designated Designated


Router Router Router

Auto-RP is disabled by default. To enable it on a router, enter the following global configura-
tion mode command:
Router(config)#ip pim send-rp-announce type number scope ttl group-list
access-list-number

To disable a router as a candidate RP, enter the no ip pim send-rp-announce command.


As illustrated in Figure 7-45, candidate RPs send an Auto-RP RP announcement message to
the well-known group CISCO-RP-ANNOUNCE (224.0.1.39). A router configured as an RP
mapping agent listens on this well-known group address to determine which RPs act for the
various ranges of multicast group addresses.
The RP mapping agent then sends the RP-to-group mappings in an Auto-RP RP discovery
message to the well-known group CISCO-RP-DISCOVERY (224.0.1.40). PIM DRs listen to
this well-known group to determine which RPs to use.
By default, a router is not configured as a PIM RP mapping agent. To configure a router to
send Auto-RP RP discovery messages, enter the following global configuration mode
command:
Router(config)#ip pim send-rp-discovery scope ttl

ttl is the Time-To-Live value that limits the scope of the discovery message.
1439_CCNP_3.book Page 441 Wednesday, October 27, 2004 9:54 AM

Routing Multicast Traffic 441

Figure 7-45 Auto-RP Relies on the Well-Known Multicast Groups 224.0.1.39 and 224.0.1.40

RP Candidate RP Candidate

rp-announce rp-announce
Message Message

Well-Known Group
RP Mapping Agent
224.0.1.39
rp-discovery
Message

rp-discovery
Message

Well-Known Group Well-Known Group


224.0.1.40 224.0.1.40

Designated Designated Designated Designated Designated Designated


Router Router Router Router Router Router

Example 7-3 shows that Nakagawa is an RP mapping agent. The scope of the discovery mes-
sages is 16 router hops.

Example 7-3 An RP Mapping Agent Is Used to Advertise the RP-to-Group Mappings

Nakagawa(config)#ip multicast-routing
Nakagawa(config)#ip pim send-rp-discovery scope 16

To disable a router as an RP mapping agent, enter the no ip pim send-rp-discovery command.

Optional IP Multicast Routing Tasks


Optional IP multicast routing tasks include the following (as described in the following
sections):
■ Defining the scope of delivery of multicast packets
■ Joining a multicast group
■ Changing IGMP versions
1439_CCNP_3.book Page 442 Wednesday, October 27, 2004 9:54 AM

442 Chapter 7: Cisco AVVID

Defining the Scope of Delivery of Multicast Packets


The function of the TTL parameter on a multicast-enabled interface controls whether packets
are forwarded out that interface.
NOTE Only multicast packets with a TTL greater than the interface TTL threshold are forwarded on
Because the TTL field the interface. Packets with a TTL equal to or less than the interface threshold are discarded.
is used to limit the
The packet TTL is compared to the interface threshold first. The router then decrements the
range, or scope, of a
multicast transmission, packet TTL by a value of 1 upon sending the packet out the interface.
configure the TTL
threshold only on bor- The default value for the TTL threshold on an interface is 0. A value of 0 means that all
der routers. Routers on multicast packets are forwarded on the interface. To change the default TTL threshold value,
which a TTL threshold
value is configured
enter the following command in interface configuration mode:
automatically become Router(config-if)#ip multicast ttl-threshold ttl
border routers.
ttl signifies the TTL value in router hops; this value can range from 0 to 255 hops.
In Example 7-4, the TTL threshold is set to 16 router hops.

Example 7-4 The TTL Threshold Can Be Set Between 0 and 255

Router#show running-config

<output omitted>

interface FastEthernet0/0
ip address 10.1.1.2 255.255.255.0
no ip directed-broadcast
ip pim sparse-dense-mode
ip multicast ttl-threshold 16

<output omitted>

To restore the default value of 0, enter the following command in interface configuration
mode:
Router(config-if)#no ip multicast ttl-threshold

Joining a Multicast Group


Cisco routers can be configured to be members of a multicast group. Being a member of a
multicast group is useful in determining multicast reachability in a network. If a router is con-
figured to be a member of a specific multicast group, that router can respond to commands,
1439_CCNP_3.book Page 443 Wednesday, October 27, 2004 9:54 AM

Routing Multicast Traffic 443

such as ping and Internet Control Message Protocol (ICMP) echo requests, addressed to that
group. A group member router can also participate in multicast Cisco IOS software traceroute
actions.
To have the router join a multicast group, enter the following command in interface configu- NOTE
ration mode: The term interface
describes the primary
Router(config-if)#ip igmp join-group group-address interface on an attached
network. If a router has
group-address is the address of the multicast group. multiple physical inter-
faces on a single net-
The configuration shown in Example 7-5 places the router in multicast Group 224.1.1.1.
work, this protocol
needs to run on only
Example 7-5 A Router Interface Can Be Configured to Participate as a Host in a Distribution Tree one of the interfaces.
Hosts, on the other
Router#show running-config hand, need to perform
their actions on all
interfaces that have
<output omitted> memberships associ-
ated with them.
interface FastEthernet0/0
ip address 10.1.1.2 255.255.255.0
no ip directed-broadcast
ip pim sparse-dense-mode
ip multicast ttl-threshold 16
ip igmp join-group 224.1.1.1

<output omitted>

Issuing a ping command specifying that multicast group address causes all routers in that
group to respond.
To cancel a router’s membership in a multicast group, enter the no ip igmp join-group
group-address command.

Changing IGMP Versions


Cisco routers do not automatically detect the IGMP version of systems on the subnet and
dynamically switch between versions.
IGMP Version 2 mode is the default for all systems using Cisco IOS Release 11.3(2)T or
later. IGMP Version 3 is available with Cisco IOS Release 12.0(15)S or later. To determine
the current version setting for an interface, enter the following privileged command:
Router#show ip igmp interface type-number
1439_CCNP_3.book Page 444 Wednesday, October 27, 2004 9:54 AM

444 Chapter 7: Cisco AVVID

type-number represents the name of the interface on which the IGMP protocol is configured.
Example 7-6 shows sample output from the show ip igmp interface command to determine
the IGMP version.

Example 7-6 Determining the IGMP Version on an Interface

Router#show ip igmp interface fast 0/0


FastEthernet0/0 is up, line protocol is up
Internet address is 10.1.1.2/24
IGMP is enabled on interface
Current IGMP version is 2
CGMP is disabled on interface
IGMP query interval is 60 seconds
IGMP querier timeout is 120 seconds
IGMP max query response time is 10 seconds
Last member query response interval is 1000 ms
Inbound IGMP access group is not set
IGMP activity: 3 joins, 1 leaves
Multicast routing is enabled on interface
Multicast TTL threshold is 16
Multicast designated router (DR) is 10.1.1.2 (this system)
IGMP querying router is 10.1.1.2 (this system)

To enable a specific IGMP version, enter the following interface configuration mode command:
ip igmp version {3 | 2 | 1}

To restore the default value of Version 2, enter the no ip igmp version command.
Because of its unique capability to send out a single data stream to multiple clients, IP multi-
cast technologies have become the transmission method of choice for most multimedia
applications.

Cisco IP Telephony
Cisco AVVID was discussed earlier in this chapter. Cisco AVVID includes the Cisco IP Tele-
phony solution. The chapter then changed gears and explored IP multicast, which is also part
of the AVVID architecture. This chapter now looks at the Cisco IP Telephony solution in
more detail.
1439_CCNP_3.book Page 445 Wednesday, October 27, 2004 9:54 AM

Cisco IP Telephony 445

Voice over IP (VoIP) is probably the most feasible among today’s technologies for data,
voice, and video integration. VoIP is the technology that uses IP to transmit voice conversa-
tions over a data network, such as an intranet or the Internet.

Introducing the Cisco IP Telephony Solution


The Cisco IP Telephony solution relies on the stable foundation of Cisco multiprotocol routers
and Catalyst multilayer LAN switches, which are the building blocks in enterprise networks.
Cisco CallManager is the heart of an IP Telephony solution. Figures 7-46, 7-47, and 7-48
illustrate alternative CallManager deployments used in Cisco IP Telephony deployments. The
uOne Messaging System is composed of three components:
■ A uOne GateServer
■ Two back-end servers (the directory server and the message server)
These components run on a Sun Sparc server.

Figure 7-46 No Geographic Limitations Exist for Deploying CallManager Servers

CallManager
Cluster Applications
(VMail, IVR, ICO,...)

GK

V V

PSTN

West Coast Headquarters Branch Office


(with SRST and APPs) (with Call Processing and Apps)

IP WAN

Rest of the World


East Coast
Headquarters
1439_CCNP_3.book Page 446 Wednesday, October 27, 2004 9:54 AM

446 Chapter 7: Cisco AVVID

Figure 7-47 CallManager Provides a Migration Path from Legacy to Pure IP Telephony Solutions

PSTN

Cisco
CallManager
Router
V IP WAN

Figure 7-48 CallManager Clusters Can Be Used for Large-Scale IP Telephony Solutions

Msg Store Msg Store


LDAP
Directory

Cisco
Cisco uOne GateServer CallManager
Cluster

IP WAN

PSTN
Catalyst
Backbone
Catalyst Wiring Closet
1439_CCNP_3.book Page 447 Wednesday, October 27, 2004 9:54 AM

Cisco IP Telephony 447

Cisco CallManager is the software-based call-processing component and essentially is the


heart of the Cisco IP Telephony solution. The software extends enterprise telephony features
and functions to packet telephony network devices such as IP Phones, media processing
devices, voice over IP (VoIP) gateways, and multimedia applications. Additional data, voice,
and video services such as unified messaging, multimedia videoconferencing, collaborative
contact centers, and interactive multimedia response systems interact with the IP Telephony
solution through Cisco CallManager’s open telephony application programming interface (API).
The Cisco CallManager software includes a suite of integrated voice applications that per-
form ad hoc voice conferencing and browser-based attendant console functions. The key ben-
efit of all these voice applications is that special-purpose voice processing hardware is not
required.
Supplementary and enhanced services such as hold, transfer, forward, conference, multiple
line appearances, automatic route selection, speed dial, and last-number redial are available
on Cisco CallManager. It also provides extension mobility. Users can log in to any IP Phone,
and the extension and the individual’s dial privileges are applied to the phone regardless of
his or her location. This lets users access all of their personal phone features, such as fast
dials, personal contacts, voice mail, productivity applications, and more from any IP Phone
when they are away from their desks.
Multiple Cisco CallManager servers are clustered and managed as a single entity. The ability
to cluster multiple call-processing servers on an IP network is unique in the industry and pro-
vides scalability for up to 10,000 users per cluster. By interlinking multiple clusters, system
capacity can be increased to up to 100,000 users per multiple cluster system. Clustering
aggregates the power of multiple distributed Cisco CallManager servers, enhancing the scal-
ability and accessibility of the servers to phones, gateways, and applications. Triple server
redundancy improves overall system availability. Call admission control ensures that voice
QoS is maintained across constricted WAN links and automatically diverts calls to alternate
PSTN routes when WAN bandwidth is unavailable.
Figure 7-49 shows the availability and scalability of four Cisco hardware platforms when
deployed in an IP Telephony environment. Figures 7-50, 7-51, and 7-52 show the various
graphical user interface (GUI) components of CallManager and Cisco IP Phones.
1439_CCNP_3.book Page 448 Wednesday, October 27, 2004 9:54 AM

448 Chapter 7: Cisco AVVID

Figure 7-49 Several Cisco Hardware Platforms Are Available to Enable Scalable IP Telephony
Solutions

Figure 7-50 The CallManager GUI Allows for Easy Viewing of IP Phones on the Network
1439_CCNP_3.book Page 449 Wednesday, October 27, 2004 9:54 AM

Cisco IP Telephony 449

Figure 7-51 The CallManager GUI Can Display the Configuration on an Individual IP Phone

Figure 7-52 Cisco IP Phones Have a Graphical Interface Used to Enable Easy Configuration and to
Display Useful Information
1439_CCNP_3.book Page 450 Wednesday, October 27, 2004 9:54 AM

450 Chapter 7: Cisco AVVID

Cisco IP Telephony Designs


The overall goals of an IP Telephony network are as follows:
■ End-to-end IP Telephony
■ IP WAN as the primary voice path between sites, with the PSTN as the secondary
voice path
■ Lower total cost of ownership with greater flexibility
■ Enabling of new applications
Currently, four general design models apply to the majority of implementations:
■ Single-site model
■ Multiple sites with independent call processing
■ Multisite IP WAN with distributed call processing
■ Multisite IP WAN with centralized call processing
The following sections summarize the design goals and implementation guidelines for each
of these models.

Single-Site Model
The single-site model has the following design characteristics:
■ A single Cisco CallManager server or CallManager cluster
■ A maximum of 10,000 users per cluster
■ A maximum of eight servers in a Cisco CallManager cluster (four servers for primary
call processing, two for backup call processing, one database publisher, and one Trivial
File Transfer Protocol [TFTP] server)
■ A maximum of 2500 users registered with a Cisco CallManager server at any time
■ The PSTN only for all external calls
■ Digital signal processor (DSP) resources for conferencing
■ Voice mail and unified messaging components
■ A G.711 codec for all IP phone calls (80 kbps of IP bandwidth per call, uncompressed)
■ To guarantee voice quality, use Cisco LAN switches with a minimum of two queues.
Figure 7-53 illustrates the single-site design model for a Cisco IP Telephony network.
1439_CCNP_3.book Page 451 Wednesday, October 27, 2004 9:54 AM

Cisco IP Telephony 451

Figure 7-53 The Single-Site Model Uses a Single CallManager Server or CallManager Cluster

Msg Store Msg Store


LDAP
Directory

Cisco uOne
GateServer

Cisco
CallManager
Cluster

IP WAN

PSTN

Catalyst
Backbone

Catalyst Wiring Closet

Multiple Sites with Independent Call Processing


The independent multiple sites model has the following design characteristics:
■ A Cisco CallManager server or CallManager cluster at each site to provide scalable
call control
■ A maximum of 10,000 IP Phones per cluster
■ No limit on the number of clusters
■ Use of the PSTN for networking multiple sites and for all external calls
■ DSP resources for conferencing at each site
■ Voice messaging or unified messaging components at each site
■ Voice compression is not required
Figure 7-54 illustrates the multiple site with independent call processing design model for
a Cisco IP Telephony network.
1439_CCNP_3.book Page 452 Wednesday, October 27, 2004 9:54 AM

452 Chapter 7: Cisco AVVID

Figure 7-54 Multiple Sites with Independent Call Processing Use a CallManager Server or Cluster
at Each Site

PSTN
V

Multiple Sites with Distributed Call Processing


The multisite IP WAN with distributed call processing has the following design characteristics:
■ A Cisco CallManager server or CallManager cluster at each location (10,000 users
maximum per site)
■ Cisco CallManager clusters are confined to a single campus and might not span the WAN.
■ IP WAN as the primary voice path between sites, with the PSTN as the secondary
voice path
■ Transparent use of the PSTN if the IP WAN is unavailable
■ Cisco IOS gatekeeper for E.164 address resolution
■ Cisco IOS gatekeeper for admission control to the IP WAN
■ A maximum of 100 sites interconnected across the IP WAN using hub-and-spoke
topologies
1439_CCNP_3.book Page 453 Wednesday, October 27, 2004 9:54 AM

Cisco IP Telephony 453

■ Compressed voice calls are supported across the IP WAN.


■ A single WAN codec is supported.
■ DSP resources for conferencing and WAN transcoding at each site.
■ Voice mail and unified messaging components at each site.
■ The minimum bandwidth requirement for voice and data traffic is 56 kbps. For voice,
interactive video, and data, the minimum requirement is 768 kbps. In each case, the
bandwidth allocated to voice, video, and data should not exceed 75% of the total
capacity.
■ Remote sites can use Cisco IOS as well as gateways based on the Skinny Gateway
Protocol.
Figure 7-55 illustrates the multisite IP WAN with a distributed call processing design model
for a Cisco IP Telephony network.

Figure 7-55 Multiple Sites with Distributed Call Processing Use the Cisco IOS Gatekeeper for
Admission Control

PSTN V
(Secondary
Voice Path)

Site B
V

IP WAN
(Primary
Site A Voice Path)

V
Cisco IOS Gatekeeper
for Admission Control

Site C
1439_CCNP_3.book Page 454 Wednesday, October 27, 2004 9:54 AM

454 Chapter 7: Cisco AVVID

Multisite IP WAN with Centralized Call Processing


The multisite IP WAN with centralized call processing has the following design characteristics:
■ The central site supports only one active Cisco CallManager server. A cluster can con-
tain a secondary and tertiary CallManager server as long as all IP Phones served by the
cluster are registered to the same CallManager server at any given time. This is called a
centralized call processing cluster.
■ Each centralized call processing cluster supports a maximum of 2500 users (there’s no
limit on the number of remote sites). Multiple centralized call processing clusters of
2500 users at a central site can be interconnected using H.323.
■ IP Phones at remote sites do not have a local Cisco CallManager server.
■ The call admission control mechanism is based on bandwidth by location.
■ Compressed voice calls across the IP WAN are supported.
■ Manual use of the PSTN is available if the IP WAN is fully subscribed for voice traffic
(the PSTN access code must be dialed after a busy signal).
■ Dial backup is required for IP Phone service across the WAN in case the IP WAN goes
down.
■ Voice mail, unified messaging, and DSP resource components are available at the cen-
tral site only.
■ The minimum bandwidth requirement for voice and data traffic is 56 kbps. For voice,
interactive video, and data, the minimum requirement is 768 kbps. In each case, the
bandwidth allocated to voice, video, and data should not exceed 75 percent of the total
capacity.
■ Remote sites can use Cisco IOS, as well as gateways, based on the Skinny Station
Protocol.
■ If using voice mail, each site must have unique internal dial plan number ranges. Inter-
nal dial plans cannot be overlapped among remote sites if voice mail is required—no
two sites can share 1XXX.
Figure 7-56 illustrates the multisite IP WAN with a centralized call processing design model
for a Cisco IP Telephony network.

Interactive Media Activity Checkbox: Cisco IP Telephony Designs


This Interactive Media Activity reinforces the goals of Cisco IP Telephony.
1439_CCNP_3.book Page 455 Wednesday, October 27, 2004 9:54 AM

Voice Quality Issues 455

Figure 7-56 Multisite IP WAN with Centralized Call Processing Relies on a Centralized CallManager
Cluster

V
Centralized Cisco
Manager Cluster
Site B

V PSTN
Site C

IP WAN
Site A

V
Telecommuter

Voice Quality Issues


Although VoIP is one of the most useful technologies in recent history, its effective deploy-
ment is strongly dependent on the quality of service implemented for the voice traffic. IP
phones sit at the access layer, normally connected to Layer 2 switches. From the access layer
to the WAN, QoS features must be implemented to optimize voice quality.

Common Voice Issues


Two major factors affect voice quality:
■ Delayed packets—Packet delay can cause either voice quality degradation because of
the end-to-end voice latency or packet loss if the delay is variable. If the end-to-end
voice latency becomes too long (250 milliseconds (ms), for example), the conversation
begins to sound like two parties talking on a CB radio. If the delay is variable, there is a
risk of jitter buffer overruns at the receiving end.
■ Lost packets—Packet loss causes voice clipping and skips.
1439_CCNP_3.book Page 456 Wednesday, October 27, 2004 9:54 AM

456 Chapter 7: Cisco AVVID

The next sections explore common voice issues in more detail.

Delay
One of the most important design considerations in implementing voice is minimizing one-
way, end-to-end delay. Voice traffic is real-time traffic; if there is too long a delay in voice
packet delivery, speech becomes unrecognizable. Delay is inherent in voice networking and
is caused by a number of different factors, such as low-bandwidth links. An acceptable delay
is less than 200 ms.
Two kinds of delay are inherent in today’s telephony networks:
■ Propagation delay—Propagation delay is caused by the characteristics of the speed of
light traveling via a fiber-optic-based or copper-based medium.
■ Handling delay—Sometimes called serialization delay, handling delay is caused by
the devices that handle voice information. Handling delays significantly degrade voice
quality in a packet network. Delays caused by codecs are considered handling delays.
Another handling delay is the time it takes to generate a voice packet. In VoIP, the DSP
generates a frame every 10 ms. Two of these frames are then placed within one voice
packet, so the packet delay is 20 ms.
A third source of handling delay is the time it takes to move the packet to the output
queue. Cisco IOS software expedites the process of determining packet destination and
getting the packet to the output queue. The actual delay at the output queue is another
source of handling delay and should be kept under 10 ms whenever possible by using
queuing methods that are optimal for the network.

Jitter
Jitter is another factor that affects delay. Jitter is the difference between when a voice packet
is expected to be received and when it actually is received, causing discontinuity in the real-
time voice stream. Voice devices compensate for jitter by setting up a playout buffer to play
back voice smoothly. Jitter can be caused by thermal noise, bandwidth limitations, improper
impedance termination, asymmetries in clock cycles, and EMI problems.

End-to-End Delay
Figuring out the end-to-end delay is not difficult if the end-to-end signal paths/data paths, the
codec, and the packets’ payload size are known factors. Adding the delays from the endpoints
to the codecs at each end, the encoder delay (which is 5 ms for the G.711 and G.726 codecs
and 10 ms for the G.729 codec), the packet delay, and the fixed portion of the network delay
yields the connection’s end-to-end delay. Table 7-1 describes common codecs.
1439_CCNP_3.book Page 457 Wednesday, October 27, 2004 9:54 AM

Voice Quality Issues 457

Table 7-1 Codecs Are Critical Variables in Configuring VoIP Solutions

Compression
Codec Bit Rate (kbps) Framing Size Delay (ms)

G.711 PCM 64 0.125 5

G.729 CS-ACELP 8 10 15

G.729a CS-ACELP 8 10 15

Echo
Echo is voice feedback in the telephone receiver when talking. When timed properly, echo is
reassuring to the speaker. But if the echo exceeds approximately 25 ms, it can be distracting
and cause breaks in the conversation.
In a traditional telephony network, echo is normally caused by a mismatch in impedance
from the four-wire network switch conversion to the two-wire local loop and is controlled by
echo cancellers. In voice-packet-based networks, echo cancellers are built into the low bit-
rate codecs and are operated on each DSP. Echo cancellers are, by design, limited by the total
amount of time they will wait for the reflected speech to be received. This amount of time is
called an echo trail. The echo trail is normally 32 ms. VoIP has configurable echo trails of 8,
16, 24, and 32 ms.
Voice, as a class of IP network traffic, has strict requirements concerning packet loss, delay,
and delay variation (also known as jitter). To meet these requirements for voice traffic, the
Cisco IP Telephony solution includes QoS features such as classification, queuing, traffic
shaping, scheduling, Compressed Real-Time Transport Protocol (CRTP), and Transmission
Control Protocol (TCP) header compression. The QoS components of the Cisco AVVID IP
Telephony solution are provided through the rich IP traffic management, queuing, and shaping
capabilities of the Cisco AVVID network infrastructure.

Implementing QoS for Voice


Voice, video, and mission-critical data applications are important underlying productivity
tools that make a business successful. Ensuring that these applications are effectively deliv-
ered requires skillful traffic management, particularly within the context of an integrated net-
working solution. QoS is a key Cisco AVVID network infrastructure enabling the capability
for such an environment. Figure 7-57 shows various WAN environments for which VoIP QoS
needs to be implemented.
1439_CCNP_3.book Page 458 Wednesday, October 27, 2004 9:54 AM

458 Chapter 7: Cisco AVVID

Figure 7-57 QoS Configuration Is an Integral Piece of the Integration of Voice, Video, and Data

Regional/HQ
Office
Cisco 7200
Cisco 2600
ATM/Frame
Relay
Branch
Office’s
Cisco 3600

Pt to Pt

Cisco 3600

Cisco 3600

QoS
In a converged environment, all types of traffic travel over a single transport infrastructure.
Yet not all traffic types are the same. Data is bursty, loss-intolerant, and latency-insensitive.
Voice, on the other hand, is nonbursty and has some tolerance to loss but is latency-sensitive.
The challenge is in providing the required level of service for each of these traffic types.
Running both voice and data on a common network requires the proper QoS tools to ensure
that the delay and loss parameters of voice traffic are satisfied. These tools are available as
features in IP phones, switches, and routers.

Application Considerations for QoS


The specific QoS requirements for given applications are generally determined by the three
parameters of latency, jitter, and loss. Depending on the type of application to be imple-
mented over a Cisco AVVID network infrastructure, the importance and effects of these
considerations can differ.
One-way latency for voice or videoconferencing should be no more than 150 to 200 ms, and
streaming video can tolerate up to 4- to 5-second latency. Similarly, jitter is not an issue
for streaming video, but it should be limited to 30 ms for voice and videoconferencing
applications.
Bandwidth effects also differ. For example, to support videoconferencing, the minimum
bandwidth guarantee is the size of the videoconferencing session plus 20 percent. (For
1439_CCNP_3.book Page 459 Wednesday, October 27, 2004 9:54 AM

Voice Quality Issues 459

example, a 384-kbps videoconferencing session requires 460 kbps of guaranteed priority


bandwidth.) Voice requires 17 to 106 kbps of guaranteed priority bandwidth per call (depend-
ing on the sampling rate, codec, and Layer 2 overhead), and 150 bps (plus Layer 2 overhead)
per phone of guaranteed bandwidth is required for voice control traffic.
Although planning requirements certainly vary depending on the application, Cisco AVVID
network infrastructure capabilities have the flexibility to concurrently support QoS require-
ments of voice, streaming video, video content distribution, videoconferencing, and mission-
critical data traffic all carried over a common IP-based networking environment.

Traffic Classification Types


The goal of protecting voice traffic from being run over by data traffic is accomplished by
classifying voice traffic as high-priority and then allowing it to travel in the network before
low-priority traffic, as shown in Figure 7-58. Classification can be done at Layer 2 or Layer 3.

Figure 7-58 Prioritizing Voice Traffic Is Standard Operating Procedure with QoS Configuration

Router
VoIP
1 1
(High)

Data V V
2 2 PQ 4 3 2 4 1 1
(Low)
WAN
Circuit
Data WFQ
3 3 3 3
(Low)

Data
4 4 4 4
(Low)

Classification is the first step toward achieving QoS. Ideally, this step should be done as close
to the source as possible, usually at the network’s access layer, and often at the edge of the
network.

Trust Boundaries
The concept of trust is an important and integral one to implementing QoS. As soon as the
end devices have a set class of service (CoS) or type of service (ToS), the switch has the option
of trusting them or not. If the switch does not trust the settings, it must perform reclassifica-
tion for appropriate QoS (see Figure 7-59); if the switch trusts the settings, it does not need to
do any reclassification (see Figure 7-60).
1439_CCNP_3.book Page 460 Wednesday, October 27, 2004 9:54 AM

460 Chapter 7: Cisco AVVID

Figure 7-59 The Switch Might Not Trust the Host Station’s CoS Configuration

PC Is Untrusted
Phone ASIC
Rewrites CoS = 0

CoS = 5 CoS = 5

CoS = 0 CoS = 7

Figure 7-60 A Switch May Be Configured to Trust a Host’s CoS Configuration

Trusted

CoS = 5 CoS = 5

CoS = 7 CoS = 7

The notion of trusting or not trusting forms the basis of the trust boundary. Ideally, classifica-
tion should be done as close to the source as possible. If the end device can perform this func-
tion, the trust boundary for the network is at the access layer in the wiring closet. If the device
cannot perform this function, or the wiring closet switch does not trust the classification done
by the end device, the trust boundary might shift. How this shift happens depends on the
switch’s capabilities in the wiring closet. If the switch can reclassify the packets, the trust
boundary remains in the wiring closet. If the switch cannot perform this function, the task
falls to other devices in the network going toward the backbone. In this case, the rule of
thumb is to perform reclassification at the distribution layer. This means that the trust bound-
ary has shifted to the distribution layer. It is more than likely that a high-end switch is in the
distribution layer with features to support this function. If possible, try to avoid performing
this function in the network core.
1439_CCNP_3.book Page 461 Wednesday, October 27, 2004 9:54 AM

Voice Quality Issues 461

Traffic Classification
Equally important as queuing, however, is a QoS mechanism called classification. It is
important to differentiate at all points in the network between voice and data traffic so that
queuing techniques can be applied in places such as the WAN edge. Therefore classification
“marks” voice and data frames differently so that they can be treated differently by the other
switches and routers that make up the intelligent IP network. Two standards-based methods
are used:
■ At Layer 2, 802.1p defines classes of service pertaining to that Ethernet segment, as
shown in Figure 7-61.
■ At Layer 3, the IP layer, the IP ToS field can carry different values end to end through
the network.

Figure 7-61 A Switch Can Reclassify CoS Values of Transit Voice and Data Traffic

CoS = 5
CoS = 5
CoS = 7

CoS = 2

Only "Reclassify" Data Not Trusted: phone ASIC


streams to 0-3...not 4-7, will rewrite CoS based on
2900, 3500 and 4000 will place switch configuration e.g.,
"4" into voice queue. extended COS = 2.

The capability to change the Layer 2 and Layer 3 classification parameters to values desired
by the network designer is a function inherent in the Cisco AVVID architecture. It is available
in the IP Phone integrated switch and some Catalyst switching platforms. The ability of the
network manager to manipulate these values at different points in the network defines a
parameter called the trust boundary. For example, if it is trusted that the end stations and
phones will set their QoS values correctly so that end-to-end QoS can be maintained, the trust
boundary includes the end stations. However, if it cannot be guaranteed that all end stations
behave properly and set their own priority values correctly, the capability to properly manipu-
late these parameters is available in the Catalyst switch infrastructure.
1439_CCNP_3.book Page 462 Wednesday, October 27, 2004 9:54 AM

462 Chapter 7: Cisco AVVID

Traffic Classification at Layer 2


Cisco IP Phones can mark voice packets as high-priority using CoS as well as ToS. By
default, the phone sends 802.1Q tagged packets with the CoS and ToS set to a value of 5.
Because most PCs do not have an 802.1Q-capable network interface card (NIC), they send
the packets untagged without an 802.1Q field (see Figure 7-62). Unless the applications run-
ning on the PC send packets with a specific CoS value, this field is 0. A special case is where
the TCP/IP stack in the PC has been modified to send all packets with a ToS value other than
0. Typically this does not happen, and the ToS value is 0.

Figure 7-62 IEEE 802.1Q Frames Include 3 Bits for IEEE 802.1p Tagging

6 Destination Address

6 Source Address
802.1p
(3 bits)
2 Type = 8100

2 Tag Control Info


CoS CFI
2 Type/Length
VLAN ID
42~1500

MAC DATA
IEEE 802.1Q Tag

PAD

4 FCS

Even if the PC is sending tagged frames with a specific CoS value, Cisco IP Phones can zero
out this value before sending the frames to the switch. This is the default behavior. Frames
coming from the phone have a CoS of 5, and frames coming from the PC have a CoS of 0.
When the switch receives these frames, it can take into account these values for further pro-
cessing based on its capabilities.
The switch uses its queues (available on a per-port basis) to buffer incoming frames before
sending them to the switching engine. (It is important to remember that input queuing comes
into play only when there is congestion.) The switch uses the CoS value(s) to put the frames
1439_CCNP_3.book Page 463 Wednesday, October 27, 2004 9:54 AM

Voice Quality Issues 463

in appropriate queues. The switch can also employ mechanisms such as Weighted Random
Early Detection (WRED) to make intelligent drops within a queue (also known as congestion
avoidance) and Weighted Round-Robin (WRR) to provide more bandwidth to some queues
than to others (also known as congestion management).
There might be times, however, when it is desirable to trust the PC CoS (if sending tagged
packets), such as when there is absolute certainty that the PC CoS has the desired value. Or
there might be times when it is desirable to assign a value other than 0. This can be achieved
on Catalyst switches as well.

Traffic Classification at Layer 3


Using the 802.1p bits within the 802.1Q tag provides the desired QoS results at Layer 2.
When traffic has to cross a Layer 3 boundary, however, it becomes imperative to implement
these mechanisms using Layer 3 parameters, such as the 3 IP precedence bits (commonly
called ToS) or the new Differentiated Services Code Point (DSCP) parameter, which uses the
6 most significant bits within the IP header’s ToS byte (see Figure 7-63 and Table 7-2). Traffic
crosses a Layer 3 boundary when packets are routed between subnets by Layer 3 switches or
routers. Traffic also crosses a Layer 3 boundary when packets need to go out of the campus
network onto the WAN through edge routers. When this happens, Layer 2 classification does
not help. Layer 3 classification is needed to achieve the desired level of QoS. All the QoS
techniques employed by the routers (including the very important WAN QoS) rely on Layer 3
classification.

Figure 7-63 8 Bits for Differentiated Code Point Classification Are Included in the IPv4 ToS Byte

Bits: 0 1 2 3 4 5 6 7 Bits: 0 1 2 3 4 5 6 7

DS-Field IPv4 ToS


DSCP CU Precedence Type of Service MBZ
Byte

Class
Selector Currently DTR – Bits Must
Codepoints Unused Be
RFC 1122
Zero

Differentiated Services Codepoint (DSCP) RFC 2474 RFC 1349

Table 7-2 lists IP Precedence and ToS values.


1439_CCNP_3.book Page 464 Wednesday, October 27, 2004 9:54 AM

464 Chapter 7: Cisco AVVID

Table 7-2 IP Precedence and ToS Values

Bits (0 to 2): IP Precedence Defined Bits (3 to 6): Type of Service Defined

111 (Network Control) 0000 (all normal)

110 (Internetwork Control) 1000 (minimize delay)

101 (CRITIC/ECP) 0100 (maximize throughput)

100 (Flash) 0010 (maximize reliability)

101 (Immediate) 0001 (minimize monetary cost)

001 (Priority)

000 (Routine)

Layer 3 classification can be achieved by using the appropriate platforms in the campus. Begin-
ning with the IP phones, packets are already presented to the switch with CoS = ToS = 5. This
Layer 3 classification is preserved even if the packets travel all the way through to the WAN
edge router where the Layer 2 header is removed. So, if the trust boundary is at the source (IP
phone), voice traffic has the ToS bits set to 5 and is presented to the network devices for
appropriate treatment. WAN routers can use this classification to employ any of the queuing
techniques. If the trust boundary is not at the source and packets need to be reclassified, the
device performing this function should be able to do it at Layer 3 before it can cross a Layer 3
boundary.

Summary Recommendations for QoS Implementation


■ Create a trust boundary at the network edge in the wiring closet. Make ports trusted
on the wiring closet switch where IP phones are attached.
■ Reclassify ToS at the edge if devices cannot be trusted.
■ Shrink the trust boundary to the distribution layer and reclassify ToS there if reclassifi-
cation is not possible at the edge.
■ Use a priority queue if possible for delay-sensitive traffic.
■ Use QoS ACLs for more granular classification of packets using Layer 4 information.
■ Use policing if necessary to limit traffic for individual flows as well as aggregate flows.
■ Have traffic going to the WAN edge classified at Layer 3 so that the router can use it for
advanced WAN queuing mechanisms.
■ Use a WAN edge router as the classifier for very small remote site networks where a
Layer 3-capable switch is unavailable.
1439_CCNP_3.book Page 465 Wednesday, October 27, 2004 9:54 AM

Network Design Issues for Voice 465

Network Design Issues for Voice


Implementing an IP Telephony solution must be preceded by a major design effort. Issues to
consider involve the method of powering IP phones, how voice and data traffic are categorized
into VLANs, redundancy, and QoS. The following sections cover each of these considerations
in greater detail.

IP Phone Physical Connectivity


Cisco IP Phones, which connect to a switch port, also provide connectivity for an attached
computer. The phone electronics, which include a three-port switch, preserve the switched
connectivity model for the computer and ensure quality of service for both the IP Phone and
the downstream computer.
Several options exist for physically connecting the IP Phone to the network. The first option
is to connect the IP Phone to the switch and to connect the data device (computer or worksta-
tion) to the switched Ethernet port on the IP Phone. This is the most common connectivity
option, and it helps with rapid deployment with minimal modifications to the existing envi-
ronment. This arrangement has the advantage of using a single port on the switch to provide
connectivity to both devices. Also, no changes to the cabling plant are required if the IP
Phone is line-powered. In this case, the switch must be able to provide ample power to all
the phones and must receive sufficient power from the AC outlet.
The second option is to connect the IP Phone and the computer using different switch ports.
Although this option doubles the switch port count for every user, it provides a level of redun-
dancy for the user. If the IP Phone goes down, the PC is unaffected, and vice versa. Also, the
IP Phone and PC ports can be connected on different modules, thus achieving another layer
of redundancy by providing protection for one of the devices if either module goes down.
The third option differs from the others in that the phone is not a hardware device, but a Java
Telephony Application Programming Interface (JTAPI) application running on a computer.
This option, the Cisco IP SoftPhone, could be particularly useful in environments where the
need for a separate handset is minimal.

Power/Protection Options
Reliable power is vital to IP Telephony. An uninterruptible power supply (UPS) can be used
to ensure a reliable and highly available infrastructure by protecting it from power failures.
Each UPS has some amount of battery that keeps the equipment running for a certain period
of time. The UPS can be configured with the appropriate amount of battery for desired
results. Most Cisco AVVID products do not ordinarily come with a backup power supply.
1439_CCNP_3.book Page 466 Wednesday, October 27, 2004 9:54 AM

466 Chapter 7: Cisco AVVID

Here are some common strategies for using a UPS:


■ Back up the wiring closet switches and downstream data center using UPS. Although
this strategy ensures that power is maintained to the phones, wall-powered devices such
as PCs can still go down.
■ Back up the whole building using UPS. This protects all devices and equipment from
power failures. Protecting PCs in this fashion is useful because of the new breed of
highly available data applications.
■ Provide a separate generator for power (besides the feed from the utility company) and
use it as backup. In this case, a UPS should be added because it usually takes a few
minutes for the generator to ramp up. The advantage of this strategy is that less battery
time is needed for each UPS.
In addition, UPS can be configured with options such as Simple Network Management Proto-
col (SNMP), remote monitoring, alarm reporting, and so on.

Power to IP Phones
Cisco IP Phones support a variety of power options:
■ Inline power—The advantage of inline power is that it does not require a local power
outlet. Power is provided by the Ethernet switch and is passed to the IP Phone through
the four-pair unshielded twisted-pair (UTP) cabling. This also permits centralization of
power management facilities.
■ External patch panel power—If the switch does not have a power-enabled line card,
or if one is not available for the switch being used, a Cisco power patch panel can be
used. The power patch panel can be inserted in the wiring closet between the Ethernet
switch and the Cisco IP Phone.
The patch panel has a 250 W power supply and draws its power from a 110 volts alter-
nating current (VAC) source. It can accommodate 48 ports and can supply power to
each of the 48 ports at 6.3 W (see Table 7-3). A UPS is recommended for backup in the
event of a power failure.

Table 7-3 Various Power Supplies Are Available to Handle Different Numbers of IP Phones

Power Supply (Watts) IP Phones Supported at 6.3 W Per Phone

1050 60 IP Phones

1300 96 IP Phones (two modules)

2500 240 IP Phones (five modules)


1439_CCNP_3.book Page 467 Wednesday, October 27, 2004 9:54 AM

Network Design Issues for Voice 467

The actual conductors used are pins 4 and 5 (pair 1) and pins 7 and 8 (pair 4) for power
and ground return. This means that all four pairs in the Category 5 cable need to be ter-
minated at the user’s desk and in the wiring closet.
■ Wall power—A third option is to power the Cisco IP Phone from a local transformer
module plugged into a nearby outlet. The obvious drawback to individually powering
the IP Phones is the absence of centralized power protection and backup.
A combination of these power options can provide redundant power to the Cisco IP Phone.

Infrastructure Considerations
Building an end-to-end IP Telephony system requires an IP infrastructure based on Layer 2
and Layer 3 switches and routers, with switched connections to the desktop. Network design-
ers must ensure that the endpoints are connected using switched 10/100 Ethernet ports. The
use of hubs for shared connectivity to the switches is not recommended, because they can
interfere with the correct operation of the IP Telephony system.

High Availability
The distributed architecture of a Cisco IP Telephony solution provides the inherent availability
that is a prerequisite for voice networking. Cisco IP Telephony solutions are also inherently
scalable, allowing seamless provisioning of additional capacity for infrastructure, services,
and applications.
In the world of converged networking, in contrast to the world of the PBX, availability is
designed into a distributed system rather than into a box. Redundancy is available in the indi-
vidual hardware components for services such as power and supervisor modules. Network
redundancy, however, is achieved with a combination of hardware, software, and intelligent
network design practices.
Network redundancy is achieved at many levels. Physical connections exist from the edge
devices where IP phones and computers are attached to two spatially diverse aggregation
devices. In the event that an aggregation device fails, or connectivity is lost for any reason
(such as a broken fiber or a power outage), failover of traffic to the other device is possible.
By provisioning clusters of Cisco CallManager servers to provide resilient call control, other
servers can pick up the load if any device within the cluster fails.
Advanced Layer 3 protocols such as HSRP or fast converging routing protocols, such as
OSPF and EIGRP, can be used to provide optimum network layer convergence around
failures.
1439_CCNP_3.book Page 468 Wednesday, October 27, 2004 9:54 AM

468 Chapter 7: Cisco AVVID

Advanced tools are also available for the MAC layer (Layer 2). Tunable spanning-tree param-
eters and the new 802.1s standards allow fast convergence. Value-added features, such as
UplinkFast and BackboneFast, allow intelligently designed networks to further optimize net-
work convergence.
High availability of the underlying network plays a major role in ensuring a successful
deployment. This translates into redundancy, resiliency, and fast convergence.

IP Addressing and Management


Each IP phone requires an IP address, along with associated information such as subnet
mask, default gateway, and so on. Essentially, this means that an organization’s need for IP
addresses doubles as IP phones are assigned to all current PC users. This information can be
configured statically on the IP phone or can be provided by DHCP. Figures 7-64 and 7-65
illustrate the private and public IP addressing options for IP phones.

Figure 7-64 Using Private Addressing for IP Phones

IP Phone + PC on IP Phone + PC on
Same Switch Ports Same Switch Ports
171.68.249.100

171.68.249.100

10.1.1.1

171.68.249.101

10.1.1.1

IP Phone Uses IP Phone Uses


“10.0.0.0” Network “10.0.0.0” Network

A straightforward solution to provide IP addresses to the IP phones might be to use the same
subnet as data devices. However, many sites have IP subnets with more than 50 percent of
subnet addresses already allocated. This would require the addition of address ranges or real-
location of the existing ranges.
1439_CCNP_3.book Page 469 Wednesday, October 27, 2004 9:54 AM

Network Design Issues for Voice 469

Figure 7-65 Using Public IP Addressing with an IP Phone or Using the Same IP Address with a
Cisco IP SoftPhone

             


         !
  %  "   #
 $

  % 

  % 

  % 

& '  ())   %  & '  ())

IP phones can be placed on a separate IP subnet. The new subnet could be in a registered
address space or a private address space, such as network 10.0.0.0. Using this scheme, the PC
would be on a subnet reserved for data devices and the phone would be on a subnet reserved
for voice. Configuration on the IP phone can be minimized by having the phone learn as
much information dynamically as possible. Therefore, when the IP phone powers up, it
should get its voice subnet automatically and then send a DHCP request on that subnet for
an IP address.
The automated mechanism by which the IP phone gets its voice subnet is provided through
enhancements to the Cisco Discovery Protocol (CDP).
Cisco IP Phones use CDP to interact with the switch so that it knows that an IP phone is con-
nected to it. To provide this level of support, three new fields have been added to CDP:
■ A Voice VLAN ID (VVID) field for communicating the voice subnet to the IP phone
■ A Trigger field for soliciting a response from the connected device
■ A Power Requirement field for getting the exact power requirement from the phone
A VLAN (Layer 2) maps to a subnet (Layer 3) as a broadcast domain such that a VLAN is
equivalent to a subnet. The VVID was introduced with Release 5.5 of the Catalyst software.
This is the voice VLAN that the switch assigns to the IP phone inside the CDP message. It
allows the IP phone to get its VLAN ID automatically when it is plugged into the switch if a
VLAN is configured for the phone. If no VLAN is configured for the IP phone, the phone
resides in the switch’s native VLAN (data subnet).
1439_CCNP_3.book Page 470 Wednesday, October 27, 2004 9:54 AM

470 Chapter 7: Cisco AVVID

The Trigger field is used to force a response from the connected device. Under normal cir-
cumstances, a device sends CDP update messages at a configured interval (the default is 1
minute). If an IP phone is connected between CDP messages, it cannot receive its VVID. In
this case, the IP phone issues a trigger in the CDP message it sends to the switch, forcing the
switch to respond with a VVID.
When the switch provides inline power to an IP phone, it has no way of knowing how much
power the phone needs (this varies by model). Initially, the switch allocates 10 W and then
adjusts the delivered power according to the requirements sent by the IP phone in the CDP
message.

Implementing IP Telephony with Auxiliary VLANs


The new voice VLAN is called an auxiliary VLAN in the Catalyst software command-line
interface (CLI). In the traditional switched world, data devices reside in a data VLAN. The
new auxiliary VLAN is used to represent other types of devices collectively. Today, those
devices are IP phones (hence, the notion of a voice VLAN), but in the future, other types of
nondata devices will also be part of the auxiliary VLAN. Just as data devices come up and
reside in the native VLAN (the default VLAN), IP phones come up and reside in the auxiliary
VLAN if one has been configured on the switch. Figure 7-66 illustrates data and auxiliary
VLANs used for a workstation and IP phone, respectively.

Figure 7-66 Auxiliary VLANs Can Be Used for Cisco IP Phones and Other Nondata Devices

Phone VLAN = 200 PC VLAN = 3

When the IP phone powers up, it communicates with the switch using CDP. The switch then
provides the phone with its configured VLAN ID (voice subnet), also known as the voice
VLAN ID or VVID. Meanwhile, data devices continue to reside in the switch’s native VLAN
(default VLAN). A data device VLAN (data subnet) is called a port VLAN ID (PVID).

Voice VLAN Configuration


The voice VLAN is disabled and the CoS value is not trusted by default on Catalyst IOS
switches, such as the Catalyst 2950 and Catalyst 3550.
Before you enable the voice VLAN, you should enable QoS on the switch by entering the mls
qos global configuration command. You also must configure the port trust state to trust by
entering the mls qos trust interface configuration command.
1439_CCNP_3.book Page 471 Wednesday, October 27, 2004 9:54 AM

Network Design Issues for Voice 471

You configure the voice VLAN using the following interface configuration mode command:
switchport voice vlan {vlan-id | dot1p | none | untagged}

The argument and keyword options for this command are as follows:
■ vlan-id—The VLAN used for voice traffic. Valid IDs are from 1 to 4094. Do not enter
leading 0s.
■ dot1p—The phone uses priority tagging and VLAN 0 (the native VLAN). By default,
the Cisco IP Phone forwards the voice traffic with an 802.1p priority of 5.
■ none—The phone is not instructed through the CLI about the voice VLAN. The phone
uses the configuration from the phone keypad.
■ untagged—The phone does not tag frames and uses VLAN 4095.
To instruct the Cisco IP Phone to forward all voice traffic through a specified VLAN, use the
interface command switchport voice vlan vlan-id.
By default, the Cisco IP Phone forwards the voice traffic with an 802.1Q priority of 5. Valid
VLAN IDs are from 1 to 4094.
An alternative to specifying a particular voice VLAN on the switch is to instruct the switch
port to use 802.1p priority tagging for voice traffic and to use the default native VLAN
(VLAN 0) to carry all traffic. By default, if enabled, the Cisco IP Phone forwards the voice
traffic with an 802.1p priority of 5. Use the interface command switchport voice vlan dot1p
to specify 802.1p priority tagging of voice traffic.
To display the voice VLAN for an interface, use the show interfaces interface-id switchport
privileged EXEC command.

Connecting to the Network with Auxiliary VLANs


The following steps outline the process that takes place when an IP phone is powered up and
plugged into the network:
1. The IP phone begins a CDP exchange with the switch. The phone issues a trigger CDP
to force a response from the switch. That response contains the phone’s VVID.
2. If the IP phone is configured to use DHCP (the default), it issues a DHCP request on
the voice subnet it got from the switch. This is the recommended mode of operation.
Static addressing can be used, but it prevents mobility.
3. The IP phone gets a response from the DHCP server in the network. Along with the
DHCP response, which provides the IP address to the telephone, it is also possible to
supply the address of the TFTP server from which the phone gets its configuration. This
is done by configuring option 150 on the DHCP server and specifying the address of
1439_CCNP_3.book Page 472 Wednesday, October 27, 2004 9:54 AM

472 Chapter 7: Cisco AVVID

the TFTP server; Cisco DHCP server supports this feature. Again, it is possible to spec-
ify the TFTP server address manually, but this would limit adds, moves, and changes,
as well as remove some other benefits.
4. The IP phone contacts the TFTP server and receives a list of addresses of Cisco Call-
Manager servers. Up to three Cisco CallManager servers can be specified in the list.
This provides redundancy in case the first Cisco CallManager server in the list is
unavailable.
5. The IP phone contacts the Cisco CallManager server and registers itself, receiving in
return a configuration file and runtime code necessary for the phone to operate. For
each configuration, the IP phone receives a directory number (DN) from the Cisco Call-
Manager server to be used for calling that particular IP phone.
6. The IP phone is ready to make and receive calls.

Summary
Corporations are looking for strategies to integrate disparate networking technologies over a
single common network infrastructure. This trend started many years ago.
Cisco AVVID solutions are heavy in design and include the following:
■ IP Telephony, IP Video Conferencing, Wireless, Enterprise Mobility, Security, Virtual
Private Networks
■ Content networking
■ IP Contact Centers
■ Storage networking
Familiar applications, such as voice messaging, are also easily integrated into the AVVID
environment.
A new breed of IP-enabled unified-messaging solutions allows users to access both voice
mail and e-mail from a common server.
IP multicasting is the transmission of an IP data frame to a host group, which is identified by
a single IP address. Because the host group is identified by a single IP address rule, the IP
multicast contains a specific combination of the destination MAC address and a destination
IP address.
1439_CCNP_3.book Page 473 Wednesday, October 27, 2004 9:54 AM

Summary 473

Because of their unique capability to send a single data stream to multiple clients, IP multi-
cast technologies have become the transmission methods of choice for most multimedia
applications.
Multicast routing protocols fall into two categories: dense mode (DM) and sparse mode (SM).
DM protocols assume that almost all routers in the network will need to distribute multicast
traffic for each multicast group. SM protocols assume that relatively few routers in the network
will be involved in each multicast. The hosts belonging to the group are widely dispersed, as
might be the case for most multicasts in the Internet. SM protocols are recommended for use
in today’s networks.
IGMP is used between hosts on a LAN and the router(s) on that LAN to track of which mul-
ticast groups the hosts are members.
PIM is used between routers so that they can track which multicast packets to forward to each
other and to their directly connected LANs.
Cisco CallManager is the software-based call-processing component of the Cisco IP Telephony
solution and essentially is the heart of the IP Telephony solution. The key benefit of CallManager
and the supporting applications is that special-purpose voice-processing hardware is not
required. Supplementary and enhanced services are seamlessly added without incurring
major expense.
IP Telephony designs include the following:
■ Single-site model
■ Multiple sites with independent call processing
■ Multisite IP WAN with distributed call processing
■ Multisite IP WAN with centralized call processing
A trust boundary should be maintained in the wiring closet. If necessary, move it to the distri-
bution layer on a case-by-case basis, but avoid moving it to the network core. This advice
conforms with the general guidelines to keep the trust boundary as close to the source as
possible.
IP phone connectivity, backup power, and IP addressing are considerations of IP Telephony
design.
You can purchase line cards that can apply power to the IP phone. If you deploy IP phones
using the existing switches, you should install line cards that can apply power. Alternatively,
you could use the external Cisco power patch panel to power the phones if powered line cards
are not available for the switch. As a final option, you could use wall power.
1439_CCNP_3.book Page 474 Wednesday, October 27, 2004 9:54 AM

474 Chapter 7: Cisco AVVID

The Catalyst software can be easily configured to support enhanced features, such as auxil-
iary/voice VLANs. Figure 7-67 summarizes Cisco AVVID technologies.

Figure 7-67 Cisco AVVID Provides a Complete, Integrated Solution for Voice, Video, and Data

Internet Supply Customer Internet Workforce


E-Learning
Business Solutions Chain Care Commerce Optimization

Real-Time Messaging Collaboration Personal Productivity Conferencing


Communications
Telephone Processing Contact Routing Video Demand

Unified Content
Policy Provisioning Identity
Control Plane Delivery

Intelligent Quality of Service Security Network Availability


Network Services

Network
Platforms

Clients
1439_CCNP_3.book Page 475 Wednesday, October 27, 2004 9:54 AM

Key Terms 475

Key Terms
Auto-RP A PIM feature that automates the distribution of group-to-RP mappings.
candidate RP A router that announces its candidacy to be an RP for a PIM-SM network via
the Cisco-Announce group, 224.0.1.39.
Cisco Group Management Protocol (CGMP) A Cisco-developed protocol that runs
between Cisco routers and Catalyst switches to leverage IGMP information on Cisco routers
to make Layer 2 forwarding decisions on Catalyst switches. With CGMP, IP multicast traffic
is delivered only to Catalyst switch ports that are attached to interested receivers.
classification Using a traffic descriptor to categorize a packet within a specific group to
define that packet and make it accessible for QoS handling on the network.
codec Coder-decoder. An integrated circuit device that typically uses pulse code modula-
tion to transform analog signals into a digital bit stream and digital signals back into analog
signals. In voice over IP, voice over Frame Relay, and voice over ATM, a codec refers to a
DSP software algorithm used to compress/decompress speech or audio signals.
Conjugate Structure Algebraic Code Excited Linear Prediction (CS-ACELP) A CELP
voice compression algorithm providing 8 kbps, or 8:1 compression. Standardized in ITU-T
Recommendation G.729.
core In CBT, the router that serves as the root of the shared tree. Similar to PIM-SM’s RP.
Core-Based Trees (CBT) A multicast routing protocol introduced in September 1997 in
RFC 2201 CBT builds a shared tree like PIM-SM. CBT uses information in the IP unicast
routing table to calculate the next-hop router in the direction of the core.
Distance Vector Multicast Routing Protocol (DVMRP) The first multicast routing proto-
col, publicized in RFC 1075 in 1998. Unlike PIM, DVMRP builds a separate multicast rout-
ing table from the unicast routing table.
distribution tree A unique forwarding path for a multicast group between the source and
each subnet containing members of the multicast group.
E.164 An ITU-T recommendation for international telecommunication numbering, espe-
cially in ISDN, BISDN, and SMDS. An evolution of standard telephone numbers. Also, the
name of the field in an ATM address that contains numbers in E.164 format.
G.711 Describes the 64-kbps PCM (Pulse Code Modulation) voice-coding technique. In
G.711, encoded voice is already in the correct format for digital voice delivery in the PSTN
or through PBXs. Described in the ITU-T standard in its G-series recommendations.
1439_CCNP_3.book Page 476 Wednesday, October 27, 2004 9:54 AM

476 Chapter 7: Cisco AVVID

G.726 Describes Adaptive Differential Pulse Code Modulation (ADPCM) coding at 40, 32,
24, and 16 kbps. ADPCM-encoded voice can be interchanged between packet voice, PSTN,
and PBX networks if the PBX networks are configured to support ADPCM. Described in the
ITU-T standard in its G-series recommendations.
G.729 Describes CELP compression in which voice is coded into 8-kbps streams. This
standard has two variations (G.729 and G.729 Annex A) that differ mainly in computational
complexity; both provide speech quality similar to 32-kbps ADPCM. Described in the ITU-T
standard in its G-series recommendations.
globally scoped addresses A multicast address space in the range from 224.0.1.0 to
238.255.255.255. These addresses can be used to multicast data between organizations
and across the Internet.
GLOP address RFC 2770 proposes that the 233.0.0.0/8 address range be reserved for stati-
cally defined addresses by organizations that already have an AS number reserved. The sec-
ond and third octets are populated with the decimal equivalents of the first and second bytes
of the hexadecimal representation of the AS number.
H.320 A suite of ITU-T standard specifications for videoconferencing over circuit-
switched media such as ISDN, fractional T1, and switched-56 lines.
H.323 An extension of ITU-T standard H.320 that enables videoconferencing over LANs
and other packet-switched networks, as well as video over the Internet. H.323 is a set of com-
munications protocols used by programs such as Microsoft NetMeeting and equipment such
as Cisco routers to transmit and receive audio and video information over the Internet.
IGMP leave group message A message used by IGMPv2 to allow a host to announce its
intention to leave a multicast group. The leave message is sent to the all-routers multicast
address, 224.0.0.2.
IGMP membership query A message used by IGMP and sent to the all-hosts multicast
address, 224.0.0.1, to verify that at least one host on the subnet is still interested in receiving
traffic directed to that group. Also referred to as a general query.
IGMP membership report A message used by IGMP to indicate a host’s interest in receiv-
ing traffic for a particular multicast group.
IGMP snooping A Layer 2 multicast constraining mechanism (like CGMP) used by
switches, allowing only multicast traffic to be forwarded to those interfaces associated with
IP multicast devices. The switch snoops on the IGMP traffic between the host and the router
and keeps track of multicast groups and member ports.
IGMP Version 1 A version of IGMP that relies solely on membership query messages and
membership report messages.
1439_CCNP_3.book Page 477 Wednesday, October 27, 2004 9:54 AM

Key Terms 477

IGMP Version 2 A version of IGMP that adds the ability of a host to proactively leave a
multicast group and the ability of a router to send a group-specific query (as opposed to a
general query).
IGMP Version 3 A version of IGMP that adds support for source filtering.
Internet Group Management Protocol (IGMP) A protocol used to allow hosts to commu-
nicate to local multicast routers their desire to receive multicast traffic.
limited scope address Also called an administratively scoped address. It falls in the range
from 239.0.0.0 to 239.255.255.255 and is limited for use by a local group or organization.
link local address An IANA reserved multicast address space in the range from 224.0.0.0
to 224.0.0.255 to be used by network protocols on a local network segment.
multicast backbone (MBONE) A multicast backbone across the public Internet, built with
tunnels between DVMRP-capable Sun workstations running the mroute daemon (process).
multicast group An arbitrary group of hosts that expresses an interest in receiving a partic-
ular data stream via multicast. This group has no physical or geographic boundaries. Hosts
that are interested in receiving data flowing to a particular group must join the group using
IGMP.
Multicast OSPF (MOSPF) A multicast routing protocol specified in RFC 1584. MOSPF is
a set of extensions to OSPF enabling multicast forwarding decisions.
Network Time Protocol (NTP) Used to synchronize clocks on network devices. The multi-
cast address 224.0.1.1 is reserved for NTP operation.
PIM sparse-dense mode An alternative to pure dense mode or pure sparse mode for a
router interface. Sparse-dense mode allows individual groups to be run in either sparse or
dense mode, depending on whether RP information is available for that group. If the router
learns RP information for a particular group, it is treated as sparse mode; otherwise, that
group is treated as dense mode.
Protocol-Independent Multicast (PIM) An IP multicast routing protocol that derives its
information using RPF checks based on the unicast routing table. PIM has several variations,
including dense mode, sparse mode, sparse-dense mode, source-specific mode, and bidirec-
tional mode.
Protocol-Independent Multicast Dense Mode (PIM-DM) A PIM variation that builds a
source tree for each multicast source and uses flood-and-prune behavior.
1439_CCNP_3.book Page 478 Wednesday, October 27, 2004 9:54 AM

478 Chapter 7: Cisco AVVID

Protocol-Independent Multicast Sparse Mode (PIM-SM) A PIM variation that builds


shared trees. The root of the tree is called the rendezvous point, similar to CBT’s core.
Reverse Path Forwarding (RPF) An algorithm used to forward multicast datagrams. It
functions as follows:
■ If a router receives a datagram on an interface it uses to send unicast packets to the
source, the packet has arrived on the RPF interface.
■ If the packet arrives on the RPF interface, a router forwards the packet out the inter-
faces present in the outgoing interface list of a multicast routing table entry.
■ If the packet does not arrive on the RPF interface, the packet is silently discarded to
prevent loops.
Router-Port Group Management Protocol (RGMP) Lets a router communicate to a switch
the IP multicast group for which the router wants to receive or forward traffic. RGMP is
designed for switched Ethernet backbone networks running PIM.
RP mapping agent A router that receives the RP-announcement messages from the candi-
date RPs and arbitrates conflicts. The RP mapping agent sends the group-to-RP mappings to
all multicast-enabled routers via the Cisco-Discovery group, 224.0.1.40.
shared tree A multicast distribution tree using a root placed at some chosen point in the
network. PIM-SM and CBT both use shared trees. When using a shared tree, sources must
send their traffic to the root for the traffic to reach the receivers.
source filtering A capability added to IGMPv3 that lets a multicast host signal to a router
the groups for which it wants to receive multicast traffic and the sources from which it wants
to receive the traffic.
source tree A multicast distribution tree with root at the source of the multicast traffic and
whose branches form a spanning tree through the network to the receivers. Also called the
shortest-path tree (SPT). For every source of a multicast group, there is a corresponding SPT.
trust boundary When classifying traffic types in an enterprise network, a trust boundary
must be established. The boundary is established by the access device, which either classifies
traffic it allows into the network itself or trusts classification that has already been applied by
an end station, such as an IP phone.
1439_CCNP_3.book Page 479 Wednesday, October 27, 2004 9:54 AM

Check Your Understanding 479

Check Your Understanding


Use the following review questions to test your understanding of the concepts covered in this
chapter. Answers are listed in Appendix A, “Check Your Understanding Answer Key.”
1. What type of VLAN is commonly used with Catalyst switches to support IP phones?

A. User VLAN

B. Native VLAN

C. Auxiliary VLAN

D. Management VLAN
2. Which of the following is an indispensable software-based call-processing component
required for a Cisco IP Telephony solution?
A. LDAP

B. Gateserver

C. IOS Gatekeeper

D. CallManager
3. Different codecs have different encoding delays. These delays are added to the end-
point-to-codec delays to determine which of the following?
A. Propagation delay

B. Latency

C. Initialization delay

D. End-to-end delay
4. A priority queue is established for what type of traffic when implementing QoS for an
IP Telephony solution?
A. TCP

B. UDP

C. Data

D. Voice
5. Layer 2 traffic classification uses which of the following?

A. Type of service

B. Class of service

C. Differentiated Services Code Point

D. Voice queue
1439_CCNP_3.book Page 480 Wednesday, October 27, 2004 9:54 AM

480 Chapter 7: Cisco AVVID

6. Layer 3 traffic classification uses which of the following?

A. Type of service

B. Class of service

C. Differentiated Services Code Point

D. Voice queue
7. What is used to ensure that multicast traffic is correctly forwarded down the distribu-
tion tree?
A. LCP

B. CRTP

C. RTP

D. RPF
8. What are the two types of multicast distribution trees?

A. CBT trees

B. Shared trees

C. Shortest-path trees

D. Rendezvous trees
9. What Layer 2 multicast address corresponds to the Layer 3 multicast address
224.10.8.5?
A. FF.FF.FF.FF.FF.FF

B. 01.00.22.44.10.05

C. 01.00.5E.0A.08.05

D. 01.00.5E.10.08.05
10. What multicast protocol is used to optimize multicast traffic between hosts and routers
participating in multicast traffic flows?
A. RGMP

B. IGMP

C. CGMP

D. PIM-SM
1439_CCNP_3.book Page 481 Wednesday, October 27, 2004 9:54 AM
1439_CCNP_3.book Page 482 Monday, November 1, 2004 11:16 AM

Objectives
After completing this chapter, you will be able to perform tasks related to the following:
■ Understand loss, latency, and jitter
■ Understand the quality of service (QoS) models
■ Understand class of service (CoS), type of service (ToS), IP Precedence, and Differen-
tiated Services Code Point (DSCP)
■ Configure CoS trust and rewrite on Catalyst switches
■ Describe and configure Committed Access Rate (CAR)
■ Describe and configure Class-Based Weighted Fair Queuing (CBWFQ)
■ Describe and configure Weighted Random Early Detection (WRED)
■ Describe and configure Low Latency Queuing (LLQ)
■ Describe and configure Generic Traffic Shaping (GTS) and Frame Relay traffic shaping
■ Describe Link Fragmentation and Interleaving (LFI)
■ Describe and configure Compressed Real-Time Transport Protocol (CRTP)
■ Verify QoS configurations
1439_CCNP_3.book Page 483 Wednesday, October 27, 2004 9:54 AM

Chapter 8

Quality of Service
Increasingly, data networks are being called on to support communications for traffic with varied
delivery requirements. Previously an organization used separate networks for voice, video, and
data traffic. Now, it is common practice to combine these into a single multiservice network in
which the varied traffic types coexist. There are many circumstances in which these quality of
service (QoS) requirements have not been met or even addressed at a rudimentary level:
■ The long delay in speech transmission when calling by way of an international satellite
link
■ Stop-start and choppy Internet streaming video performance
■ Unclear audio when using an Internet-based IP phone
■ Messenger applications
For applications such as file and print services, Internet browsing, e-mail, and peer-to-peer
messaging products, the “best-effort” delivery attempts of the Internet and many corporate
networks might be adequate. However, for organizations seeking to integrate their voice and
data networks using voice over IP (VoIP), IP telephony, or high-quality streaming video for
corporate communications, it is essential that QoS be built into the network design.
To provide QoS within a network, it is critical that you understand the network characteristics
that make up QoS and the QoS requirements of the varied traffic and applications using the net-
work. As soon as you can state application and traffic requirements in QoS terms, you can use
classification techniques to identify streams of traffic as having a particular QoS requirement.
For example, you could use a standard access list to identify a user who requires priority access
to network resources. After you have classified traffic into classes of service, you can use many
scheduling and congestion management techniques to provide the desired service characteris-
tics. The key to effective QoS design is knowing how these techniques operate and the benefits
and limitations of each.
1439_CCNP_3.book Page 484 Wednesday, October 27, 2004 9:54 AM

484 Chapter 8: Quality of Service

Quality of Service Requirements


QoS is affected by an array of variables, including loss, delay, and jitter. QoS requirements
are unique to the type of traffic, such as voice, video, and data. This section defines QoS, the
motivation behind it, and the specific requirements to optimize voice, video, and data traffic.

Quality of Service Defined


QoS refers to a network’s ability to provide improved service to selected network traffic over
various underlying technologies, including Frame Relay, Asynchronous Transfer Mode
(ATM), Ethernet and 802.3 networks, Synchronous Optical Network (SONET), and IP-routed
networks. QoS can be applied in a central office or branch office or in between (see Figure 8-1),
especially to support IP telephony.

Figure 8-1 QoS Can Be Applied to Networks Regardless of the Underlying Technology. IP
Telephony Is a Major Motivator for Implementing QoS.

Intranet
Servers

Branch
VoIP Phones
WAN

Central VoIP Phones

Cisco
CallManager

QoS features provide improved and more predictable network service by offering the follow-
ing services:
■ Dedicated bandwidth
■ Improved loss characteristics
■ Congestion management
■ Congestion avoidance
■ Traffic shaping
■ Traffic prioritization
1439_CCNP_3.book Page 485 Wednesday, October 27, 2004 9:54 AM

Quality of Service Requirements 485

In a network, the goal is to move information from one point to another. The characteristics
that define the quality of this movement are
■ Loss
■ Delay or latency
■ Delay variation (also called jitter)
The following three sections discuss each of these characteristics in greater detail.

Loss
Loss refers to the percentage of packets that fail to reach their destination. Loss can result
from errors in the network, corrupted frames, and congested networks. With modern switched
and optical-based networks, corrupted frames and packet losses caused by network noise,
interference, and collisions are becoming rare. Many of the packets lost in an optimized
network are deliberately dropped by networking devices to avoid congestion. For many
Transmission Control Protocol/Internet Protocol (TCP/IP)-based traffic flows, such as those
associated with file and print services, small numbers of lost packets are of little concern
because TCP/IP’s retransmission mechanism ensures their eventual arrival. However, for
User Datagram Protocol (UDP) traffic associated with real-time applications such as stream-
ing media and voice, retransmission is not feasible and losses are less tolerable. As a guide-
line, a highly available network should suffer less than 1% loss. For voice traffic, the loss
should approach 0 percent.

Delay or Latency
Delay or latency refers to the time it takes a packet to travel from the source to the destina-
tion. Delay is composed of fixed and variable delays. Fixed delays include such events as
serialization and encoding/decoding. For example, a bit takes a fixed 100 nanoseconds (ns)
to exit a 10-Mbps Ethernet interface. Variable delays are often the result of congestion. They
include the time packets spend in network buffers waiting for access to the media. In general,
delay resulting from bidirectional network traffic is a more significant problem, because it
tends to be additive. Examples of bidirectional traffic include voice traffic and Telnet sessions
to a remote host, in which delay manifests itself as the slow acceptance of keystrokes. The
resulting latency makes it difficult to conduct a conversation without talking over the other
party.
As a design rule, a voice packet should cross the network in less than 150 milliseconds (ms).
1439_CCNP_3.book Page 486 Wednesday, October 27, 2004 9:54 AM

486 Chapter 8: Quality of Service

Delay Variation or Jitter


Delay variation or jitter is the difference in the delay times of consecutive packets. A jitter
buffer is often used to smooth out arrival times, but buffering capabilities have instantaneous
and total limits. Any type of buffering used to reduce jitter directly increases total network
delay. In general, traffic requiring low latency also requires a minimum variation in latency.
As a design rule, voice networks cannot cope with more than 30 ms of jitter. Jitter greater
than 30 ms results in degraded audio performance. Excessive jitter in a streaming video envi-
ronment results in jerky motion, loss of video quality, or loss of video.

Network Availability
Providing QoS requires maximizing network uptime. Low loss, small delays, and minimal
jitter are meaningless if the network is down. Redundancy, dynamic routing protocols, Hot
Standby Router Protocol (HSRP), and Spanning Tree Protocol (STP) are all used to create a
highly available network and to form the foundation of a network that can fulfill QoS require-
ments. Figure 8-2 illustrates the redundancy and maximizing of network availability as pro-
vided by HSRP and STP.

Figure 8-2 Maximizing Network Availability with STP and HSRP by Providing Layer 2 and Layer 3
Redundancy

ISP 1 ISP 2

Multihomed WAN or
Redundant Core Layer

HSRP

STP
1439_CCNP_3.book Page 487 Wednesday, October 27, 2004 9:54 AM

Quality of Service Requirements 487

Provisioning
You might find it surprising that bandwidth is not listed as an element of QoS. Inadequate
bandwidth inflates latency as packets spend increasing amounts of time queued in network
devices. In seriously congested networks, inadequate bandwidth results in loss of data as
queues overflow. Meeting QoS requirements is impossible if network LAN and wide area
network (WAN) links have insufficient bandwidth. Adding bandwidth, also known as over-
provisioning, does not solve the problem. The possibility of an overprovisioned network
becoming congested is reduced. If the network does become congested, it might not perform
as well as a lower-bandwidth, lower-cost network that makes use of sophisticated QoS features.
Figure 8-3 illustrates provisioning.

Figure 8-3 Sometimes a Lower-Bandwidth Network with Intelligent QoS Performs Better Than an
Overprovisioned Network That Becomes Congested

Shared Burst Area Sold to


Many Customers

C Customer
D
A

B
12 E
OC
-N
13
LA
Vo N V
ice oI
Vid P In
eo ter
Da net
ta

11 STSNcDIP Pkts
STSNcDATM Cells
ATM Ethernet
Ds3-Leased Line
Ds1-Voice
TDM IP
Ds1-Voice

Quality of Service Requirements for Data


Different applications, protocols, and traffic types have different QoS requirements in terms
of the amount of loss, latency, and jitter they can tolerate. Recognizing these differences is an
essential element in designing and configuring a network that delivers the required QoS.
When addressing the QoS needs of data application traffic, profile the applications to get a
basic understanding of the network requirements. It is not necessary to overengineer the
1439_CCNP_3.book Page 488 Wednesday, October 27, 2004 9:54 AM

488 Chapter 8: Quality of Service

provisioning of bandwidth, because some traffic can usually tolerate lower QoS levels.
Instead, use the proven relative priority model to divide traffic into no more than four classes:
■ Gold (mission-critical)—Transactional and business software
■ Silver (guaranteed bandwidth)—Streaming video, messaging, and intranet
■ Bronze (best-effort and default class)—Internet browsing, e-mail
■ Less-Than-Best-Effort (Optional; higher-drop preferences)—File Transfer Protocol
(FTP), backups, and applications (such as Napster or KaZaa)

Quality of Service Requirements for Voice


Voice quality is directly affected by all three QoS factors—loss, delay, and delay variation.
Recommended parameters are as follows:
■ Loss should be no more than 1 percent
■ One-way latency should be no more than 150 to 200 ms
■ Average jitter should be no more than 30 ms
■ 21 to 106 kbps of guaranteed priority bandwidth is required per call, depending on the
sampling rate, codec, and Layer 2 overhead
Loss causes voice clipping and skips. Industry-standard codec algorithms can correct for up
to 30 ms of lost voice. Cisco VoIP technology uses 20-ms samples of voice payload per VoIP
packet. Only a single Real-Time Transport Protocol (RTP) packet can be lost at any given
time. If two successive voice packets are lost, the 30-ms correctable window is exceeded, and
voice quality begins to degrade.
Delay can cause voice quality degradation if the delay exceeds 200 ms. If the end-to-end
voice delay becomes too long, the conversation sounds as if the two parties are talking over a
satellite link or a CB radio. The International Telecommunication Union (ITU) standard for
VoIP, G.114, states that a 150-ms one-way delay budget is acceptable for high voice quality.
With respect to delay variation, adaptive jitter buffers exist within IP Telephony devices that
can usually compensate for 20 to 50 ms of jitter.

Quality of Service Requirements for Video


Streaming video applications have more-lenient QoS requirements because they are
delay-insensitive. A video can take several seconds to cue up and is largely delay variation-
insensitive because of application buffering. Streaming video might contain valuable content,
1439_CCNP_3.book Page 489 Wednesday, October 27, 2004 9:54 AM

Quality of Service Requirements 489

as in the case of an e-learning application, and might require service guarantees using QoS.
Streaming video would be appropriately provisioned in the “Silver” class of data traffic.
When provisioning for streaming video, take into account the video content distribution
requirements. Recommended QoS parameters for streaming video traffic are as follows:
■ Loss should be no more than 2 percent
■ Latency should be no more than 4 to 5 seconds
■ There are no significant jitter requirements
■ Bandwidth requirements depend on the encoding and rate of the video stream
■ Non-entertainment streaming video should be provisioned into the “Silver” data
traffic class
Video file distribution is very similar to FTP traffic and can have a major impact on network
performance because of the file size. Distribution traffic should be managed to avoid affecting
the network using the following QoS parameters for video content transfers:
■ Streaming video content is delay- and delay-variation insensitive.
■ Streaming video requires large file transfers.
■ Try to restrict distribution to less-busy times of day.
■ Provision as “less-than-best-effort” data.
■ The minimum bandwidth guarantee is the size of the videoconferencing session plus
20 percent.
When addressing the QoS needs of videoconferencing traffic, the basic requirements are
similar to those for voice (see Figure 8-4):
■ Loss should be no more than 1%.
■ One-way latency should be no more than 150 to 200 ms.
■ The average jitter should be no more than 30 ms.
■ Because of its bursty nature, the minimum bandwidth guarantee is the size of the
videoconferencing session plus 20 percent.
As Figure 8-4 illustrates, this means that a 384-kbps videoconferencing session requires
460 kbps guaranteed priority bandwidth.
1439_CCNP_3.book Page 490 Wednesday, October 27, 2004 9:54 AM

490 Chapter 8: Quality of Service

Figure 8-4 Videoconferencing Bandwidth Requirements for a 384-kbps Session

Video conferencing Bandwidth Requirements for a 384-Kbps Session

"I" Frame "I" Frame


(Full-Sample Video) (Full-Sample Video)
1024 to 1518 Bytes 1024 to 1518 Bytes
600 kbps

30 pps

"P" and "B" Frames


Differential/Predicted Frames
128 to 256 Bytes

15 pps
35 kbps

I = Intra-Frame
P = Predictive
B = Bidirectional

Quality of Service Mechanisms


After you’ve defined the network’s QoS requirements, the next step is to select an appropriate
service model. A service model is a general approach or a design philosophy for handling the
competing streams of traffic within a network. There are three service models from which to
choose:
■ Best-effort
■ Integrated
■ Differentiated
The service model you select must be capable of meeting the network’s QoS requirements
and integrating any networked applications.

Best-Effort Service
Best-effort is a single service model in which an application sends data whenever it must, in
any quantity, without requesting permission or first informing the network. The characteris-
tics of the best-effort service model are as follows:
■ Data is delivered if resources exist.
■ All traffic has an equal chance of being dropped because of congestion.
■ It is implemented using first-in, first-out (FIFO) queues.
1439_CCNP_3.book Page 491 Wednesday, October 27, 2004 9:54 AM

Quality of Service Mechanisms 491

For best-effort service, the network delivers data if it can, without any assurance of reliability,
delay bounds, or throughput. The Cisco IOS QoS feature that implements best-effort service
is FIFO queuing. FIFO is the default method of queuing for LAN and high-speed WAN inter-
faces on switches and routers. Best-effort service is suitable for a wide range of networked
applications, such as general file transfers, e-mail, and web browsing.

Integrated Services Model


The Integrated Services or IntServ architecture is a multiple-service model that can accom-
modate multiple QoS requirements. Its characteristics are as follows:
■ An application makes an explicit request for network resources.
■ An application must be QoS-aware.
■ It is implemented using Resource Reservation Protocol (RSVP).
■ It uses Guaranteed Rate Service or Controlled Load Service.
In this model, the application requests a specific kind of service from the network before it
sends data. The request is made by explicit signaling. The application informs the network of
its traffic profile and requests a particular kind of service that can encompass its bandwidth
and delay requirements. The application is expected to send data only after it gets a confirma-
tion from the network. The application is also expected to send data that lies within its
described traffic profile.
The network performs admission control based on information from the application and
available network resources. The network also commits to meeting the application’s QoS
requirements as long as the traffic remains within the profile specifications. The network ful-
fills its commitment by maintaining a per-flow state and then performing packet classification,
policing, and intelligent queuing based on that state.
The Cisco IOS IntServ model allows applications to make use of the Internet Engineering
Task Force (IETF) RSVP, which applications can use to signal their QoS requirements to the
router. However, the IntServ model does not scale well as additional streams are added. Each
reservation is analogous to a phone call with a guaranteed end-to-end connection.
Routers, in conjunction with RSVP, can use intelligent queuing mechanisms to provide two
types of services:
■ Guaranteed Rate Service—Allows applications to reserve bandwidth to meet their
requirements. Adaptive real-time applications, such as playback of a recorded confer-
ence, can use this kind of service.
■ Controlled Load Service—Allows applications to have low delay and high throughput
even during times of congestion. For example, adaptive real-time applications, such as
playback of a recorded conference, can use this kind of service. Cisco IOS QoS uses
RSVP with Weighted Random Early Detection (WRED) to provide this kind of service.
1439_CCNP_3.book Page 492 Wednesday, October 27, 2004 9:54 AM

492 Chapter 8: Quality of Service

Differentiated Services Model


NOTE The Differentiated Services or DiffServ architecture is an emerging standard from the IETF.
For additional informa- Its characteristics are as follows:
tion, go to Cisco.com
and search for the docu- ■ Packets are classified upon entering the network.
ment “Implementing
DiffServ for End-to-
■ QoS is classified at Layer 2 using 802.1Q/p CoS.
End Quality of Service ■ QoS is classified at Layer 3 using IP Precedence or DSCP.
Overview.”
■ Network devices use the classification to queue, shape, and police traffic flows.
■ Applications do not need to be QoS-aware.
The DiffServ architecture specifies that each packet is classified upon entry into the network.
The classification is carried in the IP packet header using either IP Precedence or the pre-
ferred Differentiated Services Code Point (DSCP). These are represented using the first 3 or
6 bits of the Type of Service (ToS) field, respectively. Classification can also be carried in the
Layer 2 frame in the form of the Class of Service (CoS) field embodied in ISL and 802.1Q
frames.
After packets are classified at the edge by access layer switches or border routers, the network
uses the classification to determine how the traffic should be queued, shaped, and policed.
Per-hop behaviors (PHBs) are often used to describe the DiffServ model. The default PHB
specifies that a packet marked with a DSCP value of 000000 (recommended) receives the
traditional best-effort service from a DiffServ-compliant node. Also, if a packet arrives at a
DiffServ-compliant node, and the DSCP value is not mapped to any other PHB, the packet is
mapped to the default PHB. Other PHBs include the Class Selector PHB, the Assured For-
warding PHB, and the Expedited Forwarding PHB.
Unlike the IntServ model, DiffServ does not require network applications be QoS-aware.

Traffic Marking
To provide QoS to varying packets and frames, you must mark them to indicate their QoS
requirements. Specific fields are used for QoS marking or classification in frames or packets,
as shown in Figure 8-5.
At the data-link layer, a raw Ethernet frame has no fields to signify its QoS requirements. If
QoS marking is required, ISL or 802.1Q/p must be used because they provide a 3-bit CoS
field. At the network layer, an IP packet contains a 1-byte ToS field, of which the first 3 bits
form the IP-Precedence field and the first 6 bits form the DSCP fields. Either of these can be
used to signify an IP packet’s QoS requirements.
1439_CCNP_3.book Page 493 Wednesday, October 27, 2004 9:54 AM

Quality of Service Mechanisms 493

Figure 8-5 It Is Important to Understand That QoS Can Be Implemented at Both Layer 2 and
Layer 3
Encapsulated Packet

Layer 2
IP Header Data
Header

Layer 2 ISL Frame

ISL Header Encapsulated Frame 1... FCS


(26 Bytes) (24.5 KB) (4 Bytes)

3 Bits Used for CoS

Layer 2 802.1Q/p Frame

Start Frame
Preamble DA SA Tag PT Data FCS
Delimiter

3 Bits Used for CoS (User Priority)

Layer 3 IPv4 Packet

Version ToS
Length Len ID Offset TTL Proto FCS IP-SA IP-DA Data
(1 Byte)

IP Precedence or DSCP

The marking of traffic at Layer 2 or 3 is crucial to providing QoS within a network. Network
devices use this marking to determine traffic’s relative priority. The decision of whether to
mark traffic at Layers 2 or 3 or both is not trivial and should be made after considering the
following points:
■ Layer 2 marking of frames can be performed for non-IP traffic.
■ Layer 2 marking of frames is the only QoS option available for switches that are not
IP-aware.
■ Layer 3 marking carries the QoS information end-to-end.
■ Older IP equipment might not understand DSCP.
Although it might seem confusing to have three options for marking traffic, in practice the
way to proceed is often determined by the capabilities of hosts, switches, and routers within
the network. In many instances, it might be necessary to use different marking techniques at
different points within a network. For this reason, it is common to do both of the following:
■ Use DSCP to mark the packets’ QoS requirements through the network’s routed layers
■ Use CoS to mark the frames to allow Layer 2 devices, such as switches, to provide for
the packets’ QoS requirements at the data-link layer
1439_CCNP_3.book Page 494 Wednesday, October 27, 2004 9:54 AM

494 Chapter 8: Quality of Service

The 3-bit CoS field present in the Layer 2 ISL and 802.1Q/p frames allows eight levels of pri-
ority to be set for each frame. These values range from 0 for the lowest priority to 7 for the
highest priority.
Although the CoS field can be used to influence the QoS treatment of packets, it does not
have the flexibility or end-to-end capability of the IP marking schemes using IP Precedence
or DSCP. For this reason, it is common to have switches set a Layer 2 CoS value for traffic
based on their ingress port and to have a router translate the CoS value into an equivalent IP
Precedence or DSCP value. This Layer 3 ToS is then used to influence the QoS as the packet
passes through network devices en route to its destination.
Table 8-1 compares associating a packet with an IP Precedence to associating a packet with
an IP DSCP QoS level.

Table 8-1 Packet Association: Comparing IP Precedence and IP DSCP QoS Level Associations

IP Precedence IP DSCP QoS Level

Layer 3 QoS marking Layer 3 QoS marking mechanism


mechanism

Relevant only to IP Relevant only to IP traffic


traffic

Superseded by DSCP

3-bit field 6-bit field (the first 3 bits are ToS)

0 = low priority 0 = low priority

7 = highest priority 63 = highest priority

Associating a packet with either IP Precedence level or an IP DSCP QoS level allows network
devices to classify traffic based on the packet’s IP Precedence and IP DSCP value, depending
on which value is marked. These markings can be used to identify traffic with similar QoS
requirements within the network, and traffic classes can be created. Traffic types that have
similar QoS requirements can be given equivalent treatment.
The IP DSCP value is the first 6 bits in the ToS byte, and the IP Precedence value is the first
3 bits in the ToS value. The IP Precedence value is actually part of the IP DSCP value. There-
fore, both values cannot be set simultaneously. If they are, the packet is marked with the IP
DSCP value. Essentially, DSCP supersedes IP Precedence.
1439_CCNP_3.book Page 495 Wednesday, October 27, 2004 9:54 AM

Quality of Service Mechanisms 495

If it is necessary to provide QoS through packet marking, and all the devices in the network
support IP DSCP marking, it is best to use the IP DSCP marking. IP DSCP markings provide
more packet-marking options than IP Precedence.
DSCP marking might be undesirable because some older devices in the network do not sup-
port IP DSCP values. In this case it might be necessary to use the IP Precedence value to
mark the packets. A maximum of eight different IP Precedence markings and 64 different
IP DSCP markings may be set.

Modular QoS Command-Line Interface (MQC)


The Modular QoS command-line interface (MQC) is central to Cisco’s model for implement-
ing IOS-based QoS solutions. The MQC breaks down the tasks associated with QoS into
modules that
■ Identify traffic flows.
■ Classify traffic flows as belonging to a common class of QoS.
■ Apply QoS policies to that class.
■ Define the interfaces on which the policy should be enforced.
The modular nature of MQC allows the reuse of common traffic classes and policies, which
provides the following benefits:
■ It simplifies the configuration.
■ It makes it more efficient to implement changes.
■ It reduces the chance of error.
MQC has three steps:
Step 1 Classify traffic using the class-map command.
Step 2 Apply QoS policies to the traffic using the policy-map command.
Step 3 Apply policies to an interface using the service-policy command.

Using the class-map Command to Define Traffic Classes


The class-map command defines a traffic class. The purpose of a traffic class is to classify
traffic that should be given a particular QoS. A traffic class contains three major elements:
■ A name
■ A series of match commands
■ If more than one match command exists in the traffic class, instructions on how to
evaluate these match commands
1439_CCNP_3.book Page 496 Wednesday, October 27, 2004 9:54 AM

496 Chapter 8: Quality of Service

The traffic class is named in the class-map command line. For example, if you enter the
class-map cisco command while configuring the traffic class in the command-line interface
(CLI), the traffic class is named cisco, as shown in Example 8-1.

Example 8-1 The class-map Defines a Traffic Class

Switch(config)#class-map cisco
Switch(config-cmap)#

match commands specify various criteria for classifying packets. Packets are checked to
determine whether they match the criteria specified in the match commands. If a packet
matches the specified criteria, that packet is considered a member of the class and is for-
warded according to the QoS specifications set in the traffic policy. Packets that fail to meet
any of the matching criteria are classified as members of the default traffic class and are sub-
ject to a separate traffic policy.
The actual criteria that can be used to establish a match vary considerably between hardware
platforms and versions of Cisco IOS software. Table 8-2 compares the supported match com-
mands on the Catalyst 2950 and Catalyst 3550.

Table 8-2 Several Match Parameters Are Available on the Catalyst 3550

Catalyst Catalyst
Match On 2950 3550 Description

access-group ✓ ✓ Access group

ip dscp ✓ ✓ A specific DSCP value or a list of values

ip precedence ✓ A specific IP Precedence value or a list of


values
any ✓ Any packet

class-map ✓ A nested class map

destination-address ✓ A destination MAC address

input-interface ✓ Selects an input interface to match on

mpls ✓ Multiprotocol Label Switching values

protocol ✓ Matches on a protocol type

source-address ✓ A source MAC address

vlan ✓ VLAN ID
1439_CCNP_3.book Page 497 Wednesday, October 27, 2004 9:54 AM

Quality of Service Mechanisms 497

In Example 8-2, any traffic that is permitted by the named ACL test is considered part of the
traffic class known as cisco.

Example 8-2 The match Command Defines What Traffic to Permit

Switch(config)#class-map cisco
Switch(config-cmap)#match access-group name test

The instruction on how to evaluate these match commands needs to be specified if more than NOTE
one match statement exists in the traffic class. You specify the evaluation instruction with one The Catalyst 2950 has
no match-any option.
of the following two options:
The default behavior of
class-map match-any the 2950 is to match
any. This can be over-
or ridden using the
match-all command.
class-map match-all

If match-any is specified as the evaluation instruction, the traffic being evaluated by the traf-
fic class must match one of the specified criteria. If match-all is specified as the evaluation
instruction, the traffic being evaluated by the traffic class must match all the specified criteria.
Example 8-3 illustrates the match-any option.

Example 8-3 The match-any Command Allows for a Match of Any Single Criteria in a List of Matchable Options

Switch(config)#class-map match-any cisco


Switch(config-cmap)#match access-group name test
Switch(config-cmap)#match input-interface fastethernet 0/1

If traffic matches a permit statement in the ACL test or the traffic originates from FastEther-
net 0/1, it is considered part of the class of traffic known as cisco.
On the Catalyst 3550 and Catalyst 6500 the MQC allows multiple traffic classes to be config-
ured as a single traffic class; this includes nested traffic classes, also called nested class maps.
This nesting can be achieved with the use of the match class-map command.

Defining the QoS Policy Using the Policy Map


The policy-map command is used to create a traffic policy. The purpose of a traffic policy is
to configure the QoS features that should be associated with the traffic that has been classified
in a user-specified traffic class. A traffic policy contains three elements:
■ Policy name
■ Traffic class specified with the class command
■ QoS policies to be applied to each class
1439_CCNP_3.book Page 498 Wednesday, October 27, 2004 9:54 AM

498 Chapter 8: Quality of Service

The policy map shown in Example 8-4 creates a traffic policy named policy1. The policy
applies to all traffic classified by the previously defined traffic class cisco and specifies that
traffic in this example should be allocated bandwidth of 3000 kbps. Any traffic that does not
belong to the class cisco forms part of the catchall class-default class and is given a default
bandwidth of 2000 kbps.

NOTE Example 8-4 The policy-map Command Creates a Traffic Policy That Configures the QoS Features
The actual policies that
Switch(config)#policy-map policy1
can be implemented are
platform-dependent. Switch(config-pmap)#class cisco
Example 8-4 is rele-
Switch(config-pmap-c)#bandwidth 3000
vant for a Catalyst 3550
or Catalyst 6500; how- Switch(config-pmap-c)#exit
ever, the Catalyst 2950 Switch(config-pmap)#class class-default
does not support the
bandwidth command. Switch(config-pmap-c)#bandwidth 2000
Table 8-3 describes the Switch(config-pmap-c)#exit
QoS policy parameters
for 2950s and 3550s.
Table 8-3 QoS Policy Parameters on the Catalyst 2950 and 3550

Catalyst Catalyst
Action 2950 3550 Description

bandwidth ✓ Limits bandwidth to kbps.

set ip dscp ✓ ✓ Marks frames with a specific DSCP value.


set ip precedence ✓ Marks frames with a specific IP Precedence
value.

trust cos ✓ Trusts the frame’s CoS.

trust dscp ✓ Trusts the packet’s DSCP.

ip-precedence ✓ Trusts the packet’s IP Precedence.

police ✓ Enforces bandwidth and flow characteris-


tics on traffic.

The MQC does not necessarily require that users associate only one traffic class to one traffic
policy. When packets match more than one match criterion, multiple traffic classes can be
associated with a single service policy.
1439_CCNP_3.book Page 499 Wednesday, October 27, 2004 9:54 AM

Classification at the Access Layer 499

Applying the Policy to an Interface Using the Service Policy


The service-policy command attaches the traffic policy, as specified with the policy-map
command, to an interface. Because the elements of the traffic policy can be applied to packets
entering and leaving the interface, it is necessary to specify whether the traffic policy charac-
teristics should be applied to incoming or outgoing packets. For instance, the service-policy
output policy1 command shown in Example 8-5 attaches all the characteristics of the traffic
policy named policy1 to the specified interface. All packets leaving the specified interface are
evaluated according to the criteria specified in the traffic policy named policy1.

Example 8-5 The service-policy Command Attaches a Policy to an Interface

Switch(config)#interface fastethernet 0/1


Switch(config-if)#service-policy output policy1
Switch(config-if)#exit

Classification at the Access Layer


To be effective, QoS should be implemented end-to-end within a network. Best practice is to
classify traffic as soon as possible and ideally at the network edge or access layer. Some net-
work devices can signify their traffic’s QoS requirements directly, and others rely on access
layer switches or border routers to perform this function on their behalf. Specifically:
End devices can specify their own CoS, IP Precedence, and DSCP QoS parameters.

or

These parameters can be classified by the switch based on the ingress port.

Frames and packets can be marked as important by using Layer 2 CoS settings in the User
Priority bits of the 802.1p portion of the 802.1Q header or the IP Precedence/DSCP bits in
the ToS byte of the Internet Protocol version 4 (IPv4) header. The following sections outline
the various classification techniques that can be applied at the ingress port of an access layer
switch.

Trusting the CoS


The 3-bit CoS field in an ISL or 802.1Q/p frame allows for a range of CoS values between 0
and 7, where 0 is the lowest priority and 7 is the highest priority. If the edge device, such as
an IP phone or PC application, can set the CoS bits, the network designer must decide whether
to trust the device. The default action is for a switch with QoS features activated not to trust
1439_CCNP_3.book Page 500 Wednesday, October 27, 2004 9:54 AM

500 Chapter 8: Quality of Service

edge devices, and any frames that enter the switch have their CoS rewritten to the lowest pri-
ority of 0. If the edge device can be trusted, this default behavior must be overridden, and the
access switch must be configured to switch the frame, leaving the CoS bits untouched, as
shown in Figure 8-6.

Figure 8-6 Trusting the CoS of the Edge Devices Is One Option for Access Layer Switch
Configuration

My traffic is delay and


OK, I trust you.
loss sensitive.
I’ll forward your
I need CoS5.
frame unchanged.

PC Cisco 7960 Catalyst 2950


IP Phone Switch

802.1Q/p CoS 802.1Q/p CoS


Voice Payload Voice Payload
Frame Header 5 Frame Header 5

Configuring CoS Trust Using the IOS


Depending on the switch model, it might be necessary to first activate QoS using the global
configuration command mls qos.
The mls qos command is required on both the Catalyst 3550 and the Catalyst 6500. The
Catalyst 2950 has QoS enabled by default.
The trust is configured on the switch port using the interface command mls qos trust cos.
Example 8-6 demonstrates configuring trust (with comments for each step) on Catalyst
switches.

Example 8-6 Configuring Trust on Catalyst Switches Is Straightforward

switch(config)#mls qos
! Enables QoS functionality
switch(config-if)#mls qos trust cos
! Allows the switch to pass CoS values without changing them
switch(config-if)#mls qos cos default-cos
! Unmarked frame is given a default CoS when entering a port
1439_CCNP_3.book Page 501 Wednesday, October 27, 2004 9:54 AM

Classification at the Access Layer 501

Any ISL or 802.1Q/p frames that enter the switch port now have their CoS passed, untouched,
through the switch. If an untagged frame arrives at the switch port, the switch assigns a default
CoS to the frame before forwarding it. By default, untagged frames are assigned a CoS of 0.
This can be changed using the interface configuration command mls qos cos default-cos,
where default-cos is a number between 0 and 7.

Assigning CoS on a Per-Port Basis


For most network devices, such as PCs and printers, switch access ports can be assigned a
default port CoS value of 0, because they have no special QoS requirements. For devices
requiring a specific QoS that are unable to set the CoS value, an appropriate CoS value should
be applied to the switch port. After a switch port is configured with a default CoS, traffic that
passes through the port is automatically tagged with the required CoS value.
The CoS value assigned by the switch can be changed on a port-by-port basis using the inter-
face configuration command mls qos cos default-cos.
After you apply the mls qos cos default-cos command, and assuming that the switch has been
configured to trust the frames’ existing CoS value, the switch’s behavior is as follows:
■ If the incoming frame has no CoS, apply the default CoS.
■ If the incoming frame has a CoS, maintain the same CoS.

Rewriting the CoS


In some cases, it might be desirable not to trust any CoS value that might be present in frames
sourced from an edge device. For example, an office PC used for general applications, such
as web browsing, e-mail, and file and print services, does not require special QoS treatment.
Allowing it to request higher levels of QoS might adversely affect applications that require
guarantees of bandwidth and latency, such as voice and video.
For this reason, it is possible to use the override parameter to tell the switch to ignore any
existing CoS value that might be in the frame and apply the default value. This effectively
disables any trust configuration that might have been applied to the port previously.
The CoS value assigned by the switch can be changed on a port-by-port basis using the inter-
face configuration command mls qos cos override, as shown in Figure 8-7.
1439_CCNP_3.book Page 502 Wednesday, October 27, 2004 9:54 AM

502 Chapter 8: Quality of Service

Figure 8-7 The CoS of Incoming Frames Can Be Overridden

cos 2

cos 5

Interface 0/1
mls qos cos 2 override
Interface 0/2
mls qos cos 5 override

After you apply the mls qos cos override command, the switch rewrites the CoS value for all
incoming frames to the configured default value, regardless of any existing CoS value, as
shown in Figure 8-8.

Figure 8-8 It Might Be Prudent Not to Trust the CoS of Attached Devices

I want great I don’t trust you. I


service. I want will re-write your
CoS 5. CoS to an
acceptable level.

PC Cisco 7960 Catalyst 2950


IP Phone Switch

802.1Q/p CoS 802.1Q/p CoS


Data Payload Data Payload
Frame Header 5 Frame Header 0

Using a MAC ACL to Assign a DSCP Value


Classifying a frame’s CoS based on an ingress port is not always possible. An example of
where ingress port classification would be a problem is where an ingress port is connected to
multiple hosts through a hub or a simple workgroup switch that does not support QoS classi-
fication, as shown in Figure 8-9.
1439_CCNP_3.book Page 503 Wednesday, October 27, 2004 9:54 AM

Classification at the Access Layer 503

Figure 8-9 Not All Frames Can Be Meaningfully Assigned a CoS Based on the Ingress Port

What CoS should I


apply to these frames?

I don’t
understand CoS.

I need a CoS of 3.

A CoS of 0 will
do for me.

An IP access list could be a way of identifying traffic; however, this practice would limit QoS
classification to IP traffic. IP access lists are also problematic when equipment must move
between VLANs or when the IP address is dynamically allocated, such as DHCP. In this case,
a possible solution would be to use a Layer 2 MAC-based ACL.
The syntax for a MAC ACL is similar to that required for an IP-based ACL. Use the global
configuration command mac access-list extended name. Table 8-4 shows the syntax for
creating MAC ACLs.
In the QoS context, the permit and deny actions in the access control entries (ACEs) have NOTE
different meanings than with security ACLs: When creating an
access list, remember
■ If a match with a permit action is encountered, known as the first-match principle, the that, by default, the end
specified QoS-related action is taken. of the access list con-
tains an implicit deny
■ If a match with a deny action is encountered, the ACL being processed is skipped, and statement for every-
the next ACL is processed. thing if no match is
found before the end
■ If no match with a permit action is encountered and all the ACLs have been examined, is reached.
no QoS processing occurs on the packet.
■ If multiple ACLs are configured on an interface, the lookup stops after the packet
matches the first ACL with a permit action, and QoS processing begins.
1439_CCNP_3.book Page 504 Wednesday, October 27, 2004 9:54 AM

504 Chapter 8: Quality of Service

Table 8-4 Named MAC ACLs Are Useful When Multiple Devices Are Connected to a Single
Switch Port

Command/Parameters Description

mac access-list extended name From global configuration mode, defines an


extended MAC access list using a name.

{deny | permit} {any | host source MAC In extended MAC access list configuration
address} {any | host destination MAC mode, permits or denies any source MAC
address} [aarp | amber | appletalk | dec- address or a specific host source MAC
spanning | decnet-iv | diagnostic | dsm | address and any destination MAC address.
etype-6000 | etype-8042 | lat | lavc-sca | (Optional) You can also enter the following
mop-console | mop-dump | msdos | non-IP options:
mumps | netbios | vines-echo | vines-ip |
xns-idp] aarp | amber | appletalk | dec-spanning |
decnet-iv | diagnostic | dsm | etype-6000 |
etype-8042 | lat | lavc-sca | mop-console |
mop-dump | msdos | mumps | netbios |
vines-echo | vines-ip | xns-idp

show access-lists [number | name] Displays the access list configuration.

After a traffic class has been defined with a MAC-based ACL, a policy can be attached to that
class. A policy can contain multiple classes with different QoS actions specified for each of
them. For classification purposes, the policy class can be used to set a CoS at Layer 2 or
DSCP at Layer 3.

Lab 8.9.1 Classifying Traffic Using Class of Service at the Access Layer
This lab introduces the use of the Layer 2 CoS field as a means of classifying traffic
entering the network at the access layer.

Configuring DSCP Using a MAC ACL


In Figure 8-10, a MAC ACL is used to set the DSCP field of packets coming from a single IP
Phone, called receptionphone, within a switched network. Given that the MAC address of
the IP Phone is known to be 000.0a00.0111, a MAC ACL can be configured to identify traffic
sourced from this device.
1439_CCNP_3.book Page 505 Wednesday, October 27, 2004 9:54 AM

Classification at the Access Layer 505

Figure 8-10 MAC ACLs Can Be Used As a Basis for DSCP Marking

Switch(config)#mac access-list extended


receptionphone

Switch(config-ext-macl)#permit host
000.0a00.0111 any

Switch(config-ext-macl)#exit
DCSP 40

Any Port
any VLAN

IP

Verify the access list configuration using the show access-lists command, as shown in
Example 8-7.

Example 8-7 Verifying Access List Configuration

Switch#show access-lists
Extended MAC access list receptionphone permit host 0000.0a00.0111 any
permit host 0000.0a00.0111 any

After the traffic is identified, a class map is used to link the identified traffic to a particular
class of service. In this case, a class of service called ipphone is created, as shown in
Example 8-8.

Example 8-8 Traffic Defined by a MAC ACL Can Be Referenced in a Class Map

Switch(config)#class-map match-all ipphone


Switch(config-cmap)#match access-group name receptionphone

Verify the class map configuration using the show class-map command, as shown in
Example 8-9.
1439_CCNP_3.book Page 506 Wednesday, October 27, 2004 9:54 AM

506 Chapter 8: Quality of Service

Example 8-9 Verifying Class Map Configuration

Switch#show class-map
class map match-any class-default (id 0)
match any
class map match-all ipphone (id 2)
match access-group name receptionphone

Now that the traffic is classified, a policy map is used to define the action that should be taken
on any traffic that forms part of that class, as shown in Example 8-10. In this case, the policy
is called inbound-accesslayer, and the action is to set DSCP for the packets to 40.

Example 8-10 A Policy Map Defines the Action to Take on the Traffic Defined by the MAC ACL

Switch(config)#policy-map inbound-accesslayer
Switch(config-pmap)#class ipphone
Switch(config-pmap-c)#set ip dscp 40

Verify the policy map configuration using the show policy-map command, as shown in
Example 8-11.

Example 8-11 Verifying the Policy Map Configuration

Switch#show policy-map
Policy Map inbound-accesslayer
class ipphone
set ip dscp 40

Now that the action to be taken on packets coming from the IP Phone is defined, the only
remaining step is to tell the switch to apply the policy to the appropriate interface. In this
case, the policy is applied to all the interfaces (as shown in Example 8-12) so that QoS is
maintained regardless of the interface the IP Phone is connected to.

Example 8-12 Applying the Policy Map to All Interfaces

Switch(config)#interface range fastethernet 0/1 - 24


Switch(config-if-range)#service-policy input inbound-accesslayer

Determine the policies that are bound to a particular interface on the switch using the show
mls qos interface command, as shown in Example 8-13.
1439_CCNP_3.book Page 507 Wednesday, October 27, 2004 9:54 AM

Classification at the Access Layer 507

Example 8-13 Determining Policies Bound to an Interface

Switch#show mls qos interface fastethernet 0/1


FastEthernet0/1
Attached policy-map for Ingress: inbound-accesslayer
trust state: not trusted
trust mode: not trusted
COS override: dis
default COS: 0
pass-through: none
trust device: none

Using an IP ACL to Define the DSCP or Precedence


Using the MQC, it is possible to classify traffic based on its IP or TCP properties, as shown in
Figure 8-11.

Figure 8-11 A Named Extended IP ACL Is Commonly Used as a Basis for DSCP Marking

Switch(config)#ip access-list
extended 100

Switch(config-ext-nacl)#permit tcp
any any eq ftp

DCSP 0

Any Port
FTP

Server

For instance, to prevent large FTP downloads from disrupting more critical services, the net-
work administrator tags all FTP packets entering an access layer switch with either a low IP
Precedence of 0 or a DSCP of 0 so that the traffic can be subjected to QoS policies within the
network. In Figure 8-11, an IP ACL is used to identify the packets.
1439_CCNP_3.book Page 508 Wednesday, October 27, 2004 9:54 AM

508 Chapter 8: Quality of Service

Using the MQC command class-map, a class can be defined; in this case it is called reduced-
service, for traffic that does not require high levels of QoS. Traffic is classified as reducedservice
if it is permitted by the access list, as shown in Example 8-14.

Example 8-14 A Class Map Classifies the FTP Traffic

Switch(config)#class-map reducedservice
Switch(config-cmap)#match access-group 100

NOTE The MQC command policy-map is used in Example 8-15 to set the DSCP to 0 for this class
Both the Catalyst 2950 of traffic.
and the Catalyst 3550
support the setting of
Example 8-15 Setting the DSCP Value to 0
the DSCP. However,
only the Catalyst 3550
Switch(config)#policy-map inbound-accesslayer
supports the setting of
Precedence. This is not Switch(config-pmap)#class reducedservice
a serious problem, Switch(config-pmap-c)#set ip dscp 0
because the IP Prece-
dence field forms the
first 3 bits of the DSCP.
Therefore, by choosing Alternatively, the IP Precedence can be set using a policy map, as shown in Example 8-16.
and setting the appro-
priate DSCP value, Example 8-16 Setting the IP Precedence to 0 on a Catalyst 3550
you can still set the IP
Precedence. Switch(config)#policy-map inbound-accesslayer
Switch(config-pmap)#class reducedservice
Switch(config-pmap-c)#set ip precedence 0

Now that the action to be taken on FTP packets is defined, the only remaining step is to tell
the switch which interfaces to apply the policy to. In the case of Example 8-17, the policy is
applied to all the interfaces so that QoS is maintained regardless of which interface an FTP
source might be connected to.

Example 8-17 Applying the Policy Map to All Interfaces

Switch(config)#interface range fastethernet 0/1 - 24


Switch(config-if-range)#service-policy input inbound-accesslayer

Lab 8.9.2 Introduction to the Modular QoS Command-Line Interface


This lab introduces the concept of the DSCP, which is used to mark packets with a
QoS identifier.
1439_CCNP_3.book Page 509 Wednesday, October 27, 2004 9:54 AM

Policing and Marking 509

Policing and Marking


Traffic policing involves placing a constraint on the maximum traffic rate. When the traffic rate
reaches the configured maximum rate, excess traffic is dropped or remarked. The result is an
output rate that appears as a saw tooth with crests and troughs, as illustrated in Figure 8-12.

Figure 8-12 Policing Makes It Possible to Act on Nonconforming Packets, Such as by


Dropping Them

Traffic Traffic
Traffic

Traffic
Rate Policing Rate

Time Time

Policers define bandwidth limits for traffic. Packets that exceed the limits are said to be “out
of profile” or nonconforming. Each policer specifies the action to take for packets that are in
or out of profile. These actions, carried out by the “marker,” include the following:
■ Passing the packet through the switch without modification
■ Dropping the packet
■ Marking down the packet with a new DSCP value that is obtained from the config-
urable policed-DSCP map
Figure 8-13 provides a useful flow chart that describes policing.

Individual Policers
Individual policers apply the bandwidth limits specified in the policer separately to each
matched traffic class. This type of policer is configured within a policy map using the police
policy map configuration command.
The format of the police command on the Catalyst 3550 is as follows:
Switch(config-pmap-c)#police rate-bps burst-byte [exceed-action
{drop | policed-dscp-transmit}]

The police command on an IOS-based router operates in a similar fashion, except that the
actual DSCP values are specified as part of the command line rather than being specified as a
separate translation table, as is the case on a Catalyst switch. IOS-based routers also permit IP
Precedence to be set.
1439_CCNP_3.book Page 510 Wednesday, October 27, 2004 9:54 AM

510 Chapter 8: Quality of Service

Figure 8-13 Policed Packets Can Be Passed Through, Marked, or Dropped

Start

Read the DSCP


of the Packet

Is a Policer Configured No
for this DSCP?
Yes

Check if the Packet Is in No


Profile by Querying the Policer
Yes
Pass
Through Check Out-Of-Profile Action Drop
Configured for this Policer Drop Packet

Mark

Modify DSCP According


to the Policed-DSCP Map

Done

Aggregate Policers
Aggregate policers apply the bandwidth limits specified in an aggregate policer cumulatively
to all matched traffic flows. You configure this type of policer by specifying the aggregate
policer name within a policy map by using the police aggregate policy-map configuration
command. Specify the policer’s bandwidth limits by using the mls qos aggregate-policer
global configuration command. In this way, the aggregate policer is shared by multiple
classes of traffic within a policy map.
Example 8-18 demonstrates the operation of an aggregate policer.

Example 8-18 An Aggregate Policer on a Catalyst 3550 Applies Bandwidth Limits Cumulatively to All
Matched Traffic

mls qos
mls qos aggregate-policer pol_1mbps 1000000 16000
exceed-action drop
!---Defines the ACLs to select taffic
access-list 123 permit udp any any eq 111
access-list 145 permit tcp any eq 20 any
!---Defines the traffic classes to be policed
class-map match-all cl_udp111
match access-group 123
class-map match-all cl_tcp20
match access-group 145
1439_CCNP_3.book Page 511 Wednesday, October 27, 2004 9:54 AM

Policing and Marking 511

Example 8-18 An Aggregate Policer on a Catalyst 3550 Applies Bandwidth Limits Cumulatively to All
Matched Traffic (Continued)

!---Defines the QoS policy and attaches the policer to the traffic classes
policy-map po_test
class cl_udp111 polic aggregate pol_1mbps
class cl_tcp20 polic aggregate pol_1mpbs

Token Bucket
Policing uses a token bucket algorithm. As the switch receives each frame, a token is added to
the bucket. The bucket has a hole in it and leaks at a rate that is specified as the average traffic
rate in bits per second. Each time a token is added to the bucket, the switch performs a check
to determine if the bucket has enough room. If there is not enough room, the packet is marked
as nonconforming, and the specified policer action is taken—dropped or marked down—as
illustrated in Figure 8-14.

Figure 8-14 Token Buckets Are Often Used to Describe QoS Operation

Out-of-Profile Incoming
Tokens Tokens

Burst Size

In Profile
Tokens Leaking
at a Fixed Rate

How quickly the bucket fills is a function of the bucket depth, or burst-byte, the rate at which
the tokens are removed (rate-bps), and the duration of the burst above the average rate. The
bucket’s size imposes an upper limit on the burst length and determines the number of frames
that can be transmitted back-to-back. If the burst is short, the bucket does not overflow, and
no action is taken against the traffic flow. However, if a burst is long and at a higher rate, the
bucket overflows and the policing actions are taken against the frames in that burst.
The bucket depth, the maximum burst that is tolerated before the bucket overflows, is config-
ured by using the burst-byte option of the police policy map class configuration command or
the mls qos aggregate-policer global configuration command. The rate or average at which
1439_CCNP_3.book Page 512 Wednesday, October 27, 2004 9:54 AM

512 Chapter 8: Quality of Service

tokens are removed is configured using the rate-bps option of the police policy map class
configuration command or the mls qos aggregate-policer global configuration command.

Classification and Policing Using Committed Access Rate (CAR)


Committed Access Rate (CAR) is a multifaceted feature that implements both classification
services and policing through rate limiting. This section describes its classification capability.
CAR’s classification services allow traffic flow limits to be placed on incoming traffic. These
limits specify the average rate, rate-bps, and the burst rate, burst-byte, that are permissible.
Traffic that is nonconforming because it exceeds either the average rate or the burst rate spec-
ified can be marked down in terms of DSCP. As traffic flows through the network, networking
devices can use the adjusted DSCP to determine how the traffic should be treated. For exam-
ple, congestion management and avoidance techniques can be used to selectively drop pack-
ets from traffic that was previously marked down in terms of DSCP.
The policy map command that enables CAR and that defines a policer for the classified traffic
is as follows:
police rate-bps burst-byte [exceed-action {drop | policed-dscp-transmit}]

■ rate-bps specifies the average traffic rate in bits per second (bps). The range is 8000 to
2,000,000,000.
■ burst-byte specifies the normal burst size in bytes. The range is 8000 to 512,000,000.
You can configure up to 128 policers on ingress Gigabit-capable Ethernet ports, up to eight
policers on ingress 10/100 Ethernet ports, and up to eight policers on egress ports.
The exceed-action option specifies the action to take when the rates are exceeded. Use the
exceed-action drop keywords to drop the packet. Use the exceed-action policed-dscp-
transmit keywords to mark down the DSCP value (by using the policed DSCP map) and
send the packet.

Configuring the Policed DSCP Map


To mark down the DSCP value of nonconforming traffic, the switch uses a map to translate
between the initial DSCP value and the marked-down DSCP.
The global configuration command mls qos map policed-dscp on a Catalyst 3550 modifies
the default condition of mapping the inbound DSCP value to the same outbound DSCP.
The global configuration command syntax is as follows:
mls qos map policed-dscp dscp-list to mark-down-dscp

dscp-list consists of up to eight DSCP values to be mapped to a single mark-down-dscp value.


1439_CCNP_3.book Page 513 Wednesday, October 27, 2004 9:54 AM

Policing and Marking 513

The show mls qos maps policed-dscp command displays the current mapping, as shown in
Example 8-19. The map can be returned to its defaults with the no mls qos policed-dscp
command.

Example 8-19 Displaying DSCP Mappings with the show mls qos maps policed-dscp Command

Switch#show mls qos maps policed-dscp


Policed-dscp map:
d1: d2 0 1 2 3 4 5 6 7 8 9
------------------------------------
0: 00 01 02 03 04 05 06 07 08 09
1: 10 11 12 13 14 15 16 17 18 19
2: 20 21 22 23 24 25 26 27 28 29
3: 30 31 32 33 34 35 36 37 38 39
4: 40 41 42 43 44 45 46 47 48 49
5: 00 00 00 00 00 00 00 00 58 59
6: 60 61 62 63

Example 8-20 shows how to map DSCPs 50 to 57 to a marked-down DSCP value of 0.

Example 8-20 Many-to-One DSCP Mappings Are Possible

Switch#configure terminal
Switch(config)#mls qos map policed-dscp 50 51 52 53 54 55 56 57 to 0
Switch(config)#end
Switch#show mls qos maps policed-dscp
Policed-dscp map:
d1 d2 0 1 2 3 4 5 6 7 8 9
------------------------------------
0: 00 01 02 03 04 05 06 07 08 09
1: 10 11 12 13 14 15 16 17 18 19
2: 20 21 22 23 24 25 26 27 28 29
3: 30 31 32 33 34 35 36 37 38 39
4: 40 41 42 43 44 45 46 47 48 49
5: 00 00 00 00 00 00 00 00 58 59
6: 60 61 62 63

You read the map by taking the original DSCP in the form of “d1 d2” and reading the new
DSCP value from the intersection of the “d1” row and the “d2” column.
1439_CCNP_3.book Page 514 Wednesday, October 27, 2004 9:54 AM

514 Chapter 8: Quality of Service

Configuring Classification Using CAR


Example 8-21 shows how to create a policy map on a Catalyst 3550 by using CAR and
attaching it to an ingress interface.

Example 8-21 MQC Is Used to Configure CAR

Switch(config)#access-list 1 permit 10.1.0.0 0.0.255.255


Switch(config)#class-map ipclass1
Switch(config-cmap)#match access-group 1
Switch(config-cmap)#exit
Switch(config)#policy-map flow1t
Switch(config-pmap)#class ipclass1
Switch(config-pmap-c)#trust dscp
Switch(config-pmap-c)#police 48000 8000 exceed-action policed-dscp-transmit
Switch(config-pmap-c)#exit
Switch(config-pmap)#exit
Switch(config)#interface gigabitethernet0/1
Switch(config-if)#service-policy input flow1t

In the configuration, an IP standard ACL permits traffic from network 10.1.0.0, as shown in
Figure 8-15. For traffic matching this classification, the DSCP value in the incoming packet is
trusted. If the matched traffic exceeds an average traffic rate of 48000 bps and a normal burst
size of 8000 bytes, its DSCP is marked down based on the previously defined policed-DSCP
map and then is sent.

Figure 8-15 CAR Is Configured for Incoming Traffic from the 10.1.0.0/16 Subnet

Conformant rate. Same DSCP.


Same DSCP.

Excessive rate. Lower DSCP.

I will police everything from


10.1.0.0 by marking down the
traffic if it exceeds 48 kbps.
10.1.0.1
10.2.0.1

10.1.0.0/16 10.2.0.0/16
1439_CCNP_3.book Page 515 Wednesday, October 27, 2004 9:54 AM

Policing and Marking 515

Configuring Policing Using CAR


Example 8-22 demonstrates a policy that is strictly enforced on a Catalyst 3550 for the setup
shown in Figure 8-16.

Example 8-22 CAR Can Be Used to Strictly Enforce a Policy by Dropping Packets

Switch(config)#access-list 1 permit 10.1.0.0 0.0.255.255


Switch(config)#class-map ipclass1
Switch(config-cmap)#match access-group 1
Switch(config-cmap)#exit
Switch(config)#policy-map flow1t
Switch(config-pmap)#class ipclass1
Switch(config-pmap-c)#trust dscp
Switch(config-pmap-c)#police 48000 8000 exceed-action drop
Switch(config-pmap-c)#exit
Switch(config-pmap)#exit
Switch(config)#interface gigabitethernet0/1
Switch(config-if)#service-policy input flow1t

Figure 8-16 CAR Can Be Configured to Be Strictly Enforced by Dropping Nonconforming Packets

Any rate.
Conformant rate.
I will police everything from
10.1.0.0 by dropping traffic if
it exceeds 48 kbps. Excessive rate. Dropped.

10.1.0.0/16 10.2.0.0/16

Rather than merely marking down the DSCP value of nonconforming packets, the packets are
dropped. An IP standard ACL permits traffic from network 10.1.0.0. For traffic matching this
classification, the DSCP value in the incoming packet is trusted, and the packet is forwarded
1439_CCNP_3.book Page 516 Wednesday, October 27, 2004 9:54 AM

516 Chapter 8: Quality of Service

with the DSCP intact. If the matched traffic exceeds an average traffic rate of 48000 bps and a
normal burst size of 8000 bytes, the traffic is dropped.

Lab 8.9.3 QoS Classification and Policing Using CAR


In this lab, you use CAR to classify and police traffic.

Scheduling
The process of assigning packets to one of multiple queues, based on classification, for prior-
ity treatment through the network, is called scheduling. Here, traffic that has been subject to
classification at the network edge receives any preferential QoS treatment requested. Options
include FIFO, WFQ, and CBWFQ.

FIFO Queue
The simplest form of scheduling and the default for interfaces 2 Mbps and faster is the FIFO
queue, illustrated in Figure 8-17. The FIFO queue offers no preferential service for traffic;
packets are merely forwarded in the order they are received.

Figure 8-17 FIFO Is the Default Queuing Method on Serial Interfaces with Speeds Greater
Than T1/E1

Queue
Input Output

Traffic Flow

Weighted Fair Queuing (WFQ)


Weighted Fair Queuing (WFQ) classifies traffic entering the queue based on traffic flows, as
shown in Figure 8-18. The actual flow classification can be based on the following:
■ Source and destination addresses
■ Protocol
■ Session identifier (port/socket)
1439_CCNP_3.book Page 517 Wednesday, October 27, 2004 9:54 AM

Scheduling 517

Figure 8-18 WFQ Is the Default Queuing Method on Serial Interfaces with Speeds Less Than T1/E1

Physical Switch

Transmit Output
Input Output Queue Line
Traffic Destined Queue Queue
for Interface Classify

Weighted Fair
Weighted Scheduling
Round Robin
Queue Service



Configurable
Number of Queues

Each flow is given its own queue. In its simplest form, WFQ services each of these queues on
a round-robin basis. This means that every flow of traffic has an equal share of the available
bandwidth if it is required—hence the term, “fair” queue. The benefit for low-volume traffic
is reduced and predictable latency. For many applications, this default behavior of WFQ is
sufficient. However, some applications need specific QoS guarantees that require more than
simply “fair” access to the bandwidth. In this case, the “weight” needs to be modified so that
WFQ does not share bandwidth on a round-robin basis but is influenced by the class or prior-
ity of the traffic in the flow. Weight is determined by the following:
■ Requested QoS (IP Precedence, RSVP)
■ Frame Relay forward explicit congestion notification (FECN), backward explicit con-
gestion notification (BECN), discard eligible (DE) (for Frame Relay traffic)
■ Slow throughput (weighted fair)
Weighted fair queuing is activated on an interface using the fair-queue interface command.
Note that the queuing strategies described here apply to packets at Layer 3. Consequently,
these techniques can be used only on router interfaces. Physical interfaces on the Catalyst
3550 and Catalyst 6500 switches are used as router interfaces after the interface command no
switchport is applied.
These features are unavailable on regular Layer 2 switch ports and Layer 2 switches, such as
the Catalyst 2950.
1439_CCNP_3.book Page 518 Wednesday, October 27, 2004 9:54 AM

518 Chapter 8: Quality of Service

WFQ and IP Precedence


WFQ is IP Precedence-aware. Figure 8-19 shows the IPv4 ToS field, which includes 3 bits for
specifying the IP Precedence. WFQ can detect higher-priority packets marked with precedence
by the IP Forwarder and can schedule them faster, providing superior response time for this
traffic. Therefore, as the precedence increases, WFQ allocates more bandwidth to the conver-
sation during periods of congestion.

Figure 8-19 ToS Field in an IPv4 Packet

IPv4 Packet

Data

ToS Field

3-Bit Precedence

WFQ assigns a weight to each flow that determines the transmit order for queued packets. In
this scheme, lower weights are served first. For standard Cisco IOS WFQ, the IP Precedence
serves as a divisor to this weighting factor. For each cycle through all flows, WFQ effectively
services queues such that the proportion of bandwidth given to any IP Precedence level is the
IP Precedence plus 1. For example, if there is one flow at each precedence level, each flow
gets precedence + 1 parts of the link:
1 + 2 + 3 + 4 + 5 + 6 + 7 + 8 = 36

Therefore, precedence 0 traffic gets 1/36 of the bandwidth, precedence 1 traffic gets 2/36, and
precedence 7 traffic gets 8/36.
However, for 18 precedence-1 flows and one of each of the rest, the total is now
1 + (2*18) + 3 + 4 + 5 + 6 + 7 + 8 = 70

So an individual precedence-1 flow receives 2/70 or 1/35 of the bandwidth.


The actual allocated bandwidth changes continuously as flows are added or ended.

Lab 8.9.4 Weighted Fair Queuing


In this lab, you configure and optimize weighted fair queuing.
1439_CCNP_3.book Page 519 Wednesday, October 27, 2004 9:54 AM

Scheduling 519

Class-Based Weighted Fair Queuing (CBWFQ)


Class-Based Weighted Fair Queuing (CBWFQ) extends the standard WFQ functionality to
provide support for user-defined traffic classes as follows:
■ CBWFQ provides for up to 64 classes. Flow-based WFQ is limited to seven classifica-
tions or weights.
■ CBWFQ allows for coarser granularity. Multiple IP flows can belong to a single class.
For CBWFQ, the traffic classes are defined using match criteria including protocols, access
control lists, and input interfaces. Packets satisfying the match criteria for a class constitute
the traffic for that class, and a FIFO queue is reserved for each class. Traffic belonging to a
class is directed to the queue for that class the same way WFQ directs traffic belonging to dif-
ferent flows.
After you have defined a class according to its match criteria, you can assign characteristics
to it. To characterize a class, you specify bandwidth, weight, and maximum packet limit. The
bandwidth assigned to a class is the guaranteed bandwidth delivered to that class during con-
gestion. Packets belonging to a class are subject to the bandwidth and queue limits that char-
acterize the class, as shown in Figure 8-20. After a queue has reached its configured queue
limit, queuing of additional packets to the class causes further packets to be dropped.

Figure 8-20 The WFQ Algorithm Is Applied to Classes Rather Than to Flows

Interface

Class 1
4 BW = 64
Weight = 32
Traffic Is Grouped
Into User-Defined
Classes 2 1 4 3
Class 2
3 BW = 128 WFQ
Weight = 16 Dispatch

4 3 2 1
Class 3
2 1 BW = 32
Weight = 64

If a default class is configured with the bandwidth policy map class configuration command,
all unclassified traffic is put in a single FIFO queue and is treated according to the configured
bandwidth. If a default class is configured with the fair-queue command, all unclassified traffic
is flow-classified and given best-effort treatment. If no default class is configured, by default
the traffic that does not match any of the configured classes is flow-classified and given best-
effort treatment. As soon as a packet is classified, all the standard mechanisms that can be
used to differentiate service among the classes apply.
1439_CCNP_3.book Page 520 Wednesday, October 27, 2004 9:54 AM

520 Chapter 8: Quality of Service

For CBWFQ, the weight specified for the class becomes the weight of each packet that meets
the class’s match criteria. Packets that arrive at the output interface are classified according to
the match criteria filters specified. Each packet is then assigned the appropriate weight. The
weight for a packet belonging to a specific class is derived from the bandwidth assigned to
the class when configured. In this case, the user can configure a class’s weight.

Configuring CBWFQ
CBWFQ can be configured on Cisco routers, Catalyst 3550 switches, and Catalyst 6500
switches. The appropriate image must be loaded in each case. For example, 12.2 Enterprise
Plus or Advanced IP Services images work on Cisco routers. Recent EMI images do the trick
on 3550 switches.
In Example 8-23, incoming traffic that has been marked with a DSCP of 50 is given 40 percent
of the outbound link available bandwidth. All other traffic shares the remaining 60 percent of
bandwidth using WFQ, as illustrated in Figure 8-21. Configuring CBWFQ begins with turn-
ing on QoS functionality and defining the traffic that belongs to a particular class.

Example 8-23 The Traffic Is Defined as Packets That Have a DSCP Value of 50

Router(config)#mls qos
Router(config)#class-map prioritytraffic
Router(config)#match dscp 50

Figure 8-21 CBWFQ Permits Per-Class Bandwidth Allocation

DCSP 50 – 40%

Other DSCP Values – 60%

DSCP 0
DSCP 50
DSCP 50
DSCP 30

Example 8-24 configures a policy map defining the QoS requirements for both the priority
traffic identified and all other traffic (default).
1439_CCNP_3.book Page 521 Wednesday, October 27, 2004 9:54 AM

Scheduling 521

Example 8-24 The Policy Limits the DSCP-Defined Traffic to 40 Percent of the Bandwidth

Router(config)#policy-map prioritybw
Router(config-pmap)#class class-default
Router(config-pmap-c)#fair-queue
Router(config-pmap-c)#exit
Router(config-pmap)#class prioritytraffic
Router(config-pmap-c)#bandwidth percent 40
Router(config-pmap-c)#queue-limit 200

The queue-limit option specifies the depth of the queue for that class. Specifying a queue
limit tells the router that a tail-drop policy is to be used. Inbound traffic is placed in the queue
until it is full. As soon as the queue is full, all further packets are dropped until space is again
available. The section “Congestion Avoidance” explores an alternative way to handle con-
gested queues.
Finally, the policy has to be actually implemented by applying it to an interface, as shown in
Example 8-25.

Example 8-25 The Policy Is Applied to Outgoing Traffic on the GigabitEthernet0/1 Interface

Router(config)#interface fastethernet0/1
Router(config)#no fair-queue
Router(config-if)#service-policy output prioritybw

Configuring CBWFQ on a physical interface is possible only if the interface is in the default NOTE
queuing mode. Serial interfaces at E1 (2.048 Mbps) and below use WFQ by default, and CBWFQ cannot be
configured on the Cata-
other interfaces use FIFO by default. Enabling CBWFQ on a physical interface overrides the
lyst 2950 switch. How-
default interface queuing method. ever, it is supported on
Catalyst 6500 switches
Several useful router show commands are available for CBWFQ verification: and IOS-based routers.

■ show policy-map policy-map—Displays the configuration of all classes that make up


the specified policy map.
■ show policy-map policy-map class class-name—Displays the configuration of the
specified class of the specified policy map.
■ show policy-map interface interface-name—Displays the configuration of all classes
configured for all policy maps on the specified interface.
■ show queue interface-type interface-number—Displays queuing configuration and
statistics for a particular interface.
1439_CCNP_3.book Page 522 Wednesday, October 27, 2004 9:54 AM

522 Chapter 8: Quality of Service

The counters displayed after the show policy-map interface command is issued are updated
only if congestion is present on the interface.

CBWFQ Bandwidth Allocation


CAUTION The sum of all bandwidth allocation on an interface cannot exceed 75 percent of the total
Exercise caution when available interface bandwidth. The remaining 25 percent is used for other overhead, including
using the max-
Layer 2 overhead, routing traffic, and best-effort traffic. Bandwidth for the CBWFQ class-
reserved-bandwidth
percent command. default class is taken from the remaining 25 percent. However, under aggressive circum-
Ensure that there is stances in which it is necessary to configure more than 75 percent of the interface bandwidth
enough remaining
bandwidth to support to classes, the 75 percent maximum can be overridden using the max-reserved-bandwidth
best effort, control percent interface command.
traffic, and Layer 2
overheads.

Congestion Avoidance
Up to this point, this chapter has covered methods of dealing with congestion. When net-
works are heavily congested and the aggregate flows through a network device exceed the
bandwidth of its links or its capability to keep up, packets inevitably are dropped. TCP/IP
uses lost packets as a way of telling the sender that congestion is occurring in the network.
TCP/IP responds to lost packets by reducing the size of its congestion window, which results
in a reduced rate of transmission and alleviates congestion in the network.
The problem with dropped packets is that packets for all flows are dropped simultaneously.
This is called tail-drop, and it occurs when the ingress queue on a network device becomes
full. Consequently, all TCP/IP senders reduce their transmission speed simultaneously and
might underutilize the available bandwidth for a period of time. Eventually the TCP/IP send-
ers increase the size of their congestion window until congestion occurs again. As this cycle
continues, the TCP/IP senders tend to synchronize with one another. This symptom is called
global synchronization. This leads to several problems:
■ Bursty network traffic that makes QoS more difficult to achieve
■ Excessive retransmissions of lost packets
■ Periods of underutilization of the available bandwidth
Furthermore, although it is possible to prioritize traffic as it flows through a network device, it
is not possible to prioritize traffic when an ingress queue is full. QoS requires that ingress
queues always have some space available so that priority traffic can be received. A technique
is needed to ensure that ingress queues are never allowed to completely fill. This technique is
called congestion avoidance.
1439_CCNP_3.book Page 523 Wednesday, October 27, 2004 9:54 AM

Congestion Avoidance 523

Weighted Random Early Detection (WRED)


Weighted Random Early Detection (WRED) is a queuing technique for congestion avoidance.
WRED manages how packets are handled when an interface starts becoming congested. When
traffic begins to exceed the interface traffic thresholds before any congestion, the interface
starts dropping packets from selected flows. If the dropped packets are TCP, the TCP source
recognizes that packets are getting dropped and lowers its transmission rate. The lowered
transmission rate then reduces the traffic to the interface, avoiding congestion. Because TCP
retransmits dropped packets, no actual data loss occurs.
When the average queue size is above the maximum threshold, all packets are dropped. The
mark probability denominator is the fraction of packets dropped when the average queue size
is at the maximum threshold. For example, if the denominator is 512, one out of every 512
packets is dropped when the average queue is at the maximum threshold. When the average
queue size is above the maximum threshold, all packets are dropped. Figure 8-22 summarizes
packet drop probability.

Figure 8-22 Packet Drop Probability

1
Packet Discard Probability

Mark
Probability

0
Minimum Maximum
Threshold Threshold

Average Queue Size

WRED drops packets according to the following criteria:


■ RSVP flows are given precedence over non-RSVP flows to ensure that time-critical
packets are transmitted as required.
■ Using IP Precedence or the DSCP value of the packets, packets with higher precedence
are less likely to be dropped. If the default settings are preventing QoS, the precedence
value can be used to control how WRED determines when and how often to drop
packets.
1439_CCNP_3.book Page 524 Wednesday, October 27, 2004 9:54 AM

524 Chapter 8: Quality of Service

■ The amount of bandwidth used by the traffic flow. Flows that use the most bandwidth
are more likely to have packets dropped.
■ The weight factor defined for the interface determines how frequently packets are
dropped.
WRED chooses the packets to drop after considering these factors in combination. The net
result is that the highest-priority and lowest-bandwidth traffic is preserved. WRED differs
from standard random early detection (RED) in that RED ignores IP Precedence and instead
drops packets from all traffic flows, not selecting low-precedence or high-bandwidth flows.
By selectively dropping packets before congestion occurs, WRED prevents an interface from
getting flooded, necessitating a large number of dropped packets. This increases the overall
bandwidth usage for the interface.
An effective use of WRED is to avoid congestion on a predominantly TCP/IP network, one
that has minimal UDP traffic and no significant traffic from other networking protocols.
WRED is especially effective on core devices rather than edge devices, because the traffic
marking performed on edge devices can then affect the WRED interfaces throughout the
network.
The disadvantage of WRED is that only predominantly TCP/IP networks can benefit. WRED
has no effect on UDP traffic, though. Other protocols, such as NetWare Internetwork Packet
Exchange (IPX)/Sequenced Packet Exchange (SPX), do not respond to dropped packets by
lowering their transmission rates; they just retransmit the packets at the same rate. WRED
treats all non-TCP/IP packets as having precedence 0. In a mixed-protocol environment,
WRED might not be the best choice for queuing traffic.
WRED interfaces automatically favor high-priority, low-bandwidth traffic flows. No specific
policies are needed. However, because WRED automatically uses the IP Precedence settings
in packets, consider marking all traffic that enters the device or mark the traffic at the point
where it enters the network. Marking all traffic ensures that packets receive the service level
intended.

Configuring WRED on a Physical Interface


To enable WRED on an interface, use the interface command random-detect.
No other commands or parameters need to be specified to configure WRED on the interface
with the default parameter values.
The defaults can be changed with the following interface commands:
■ random-detect exponential-weighting-constant exponent min-threshold max-
threshold mark-prob-denominator—This command configures the weight factor
used in calculating the average queue length.
1439_CCNP_3.book Page 525 Wednesday, October 27, 2004 9:54 AM

Congestion Avoidance 525

■ random-detect precedence precedence min-threshold max-threshold mark-


prob-denominator—This command configures parameters for packets with a specific
IP Precedence. The minimum threshold for IP Precedence 0 corresponds to half the max-
imum threshold for the interface. The command must be issued for each precedence. To
configure RED, use the same parameters for each precedence. The default WRED
parameter values are based on the best available data.

Lab 8.9.5 Configuring WRED on a Physical Interface


In this lab, you configure WRED in its simplest form using the default IP Precedence
bits in a packet to determine the weighting.

Verifying WRED Configuration


The following commands can be used to verify the configuration and operation of WRED:
■ show interfaces [type slot | port-adapter | port]—Displays the WRED configuration on
an interface.
■ show queueing random-detect—Displays the queuing configuration for WRED.
■ show queue interface-type interface-number—Displays the header information of the
packets inside a queue.

Configuring WRED with CBWFQ


WRED can be combined with CBWFQ. In this combination, CBWFQ provides a guaranteed
percentage of the output bandwidth, and WRED ensures that TCP traffic is not sent faster
than CBWFQ can forward it.
The abbreviated configuration shown in Example 8-26 shows how WRED can be added to a
policy map specifying CBWFQ.

Example 8-26 WRED Can Be Combined with CBWFQ

Router(config)#policy-map prioritybw
Router(config-pmap)#class class-default
Router(config-pmap-c)#fair-queue
Router(config-pmap-c)#exit
Router(config-pmap)#class prioritytraffic
Router(config-pmap-c)#bandwidth percent 40
Router(config-pmap-c)#random-detect
1439_CCNP_3.book Page 526 Wednesday, October 27, 2004 9:54 AM

526 Chapter 8: Quality of Service

The random-detect parameter specifies that WRED is used rather than the default tail-drop
action.

Lab 8.9.6 Configuring WRED with CBWFQ


In this lab, you learn to configure CBWFQ in conjunction with WRED.

Low Latency Queuing (LLQ)


The Low Latency Queuing (LLQ) feature brings strict priority queuing (PQ) to CBWFQ.
Strict PQ allows delay-sensitive data, such as voice, to be sent before packets in other queues
are sent. Without LLQ, CBWFQ provides WFQ based on defined classes with no strict prior-
ity queue available for real-time traffic. For CBWFQ, the weight for a packet belonging to a
specific class is derived from the bandwidth assigned to the class. Therefore, the bandwidth
assigned to the packets of a class determines the order in which the packets are sent. All packets
are serviced fairly based on weight, and no class of packets may be granted strict priority.
This scheme poses problems for voice traffic, which is largely intolerant of delay, especially
variation in delay. For voice traffic, variations in delay introduce irregularities of transmission
manifesting as jitter in the heard conversation. LLQ provides strict priority queuing for
CBWFQ, reducing jitter in voice conversations, as illustrated in Figure 8-23.

Figure 8-23 LLQ Provides for Strict Priority Queuing of Voice Traffic (V)

Interface
V V
Priority Class 1 1
Class 1 2 2 PQ V V
4 3 2 1 1
Class 2 3 3 3 3
Class 3 4 4 4 4 WFQ
Class-Default 5 5 5

LLQ enables the use of a single, strict priority queue within CBWFQ at the class level. Any
class can be made a priority queue by adding the priority keyword. Within a policy map, one
or more classes can be given priority status. When multiple classes within a single policy map
are configured as priority classes, all traffic from these classes is sent to the same, single,
strict priority queue.
Although it is possible to queue various types of real-time traffic to the strict priority queue, it
is strongly recommended that only voice traffic be sent to the strict priority queue because
1439_CCNP_3.book Page 527 Wednesday, October 27, 2004 9:54 AM

Congestion Avoidance 527

voice traffic is well-behaved, whereas other types of real-time traffic are not. Moreover, voice
traffic requires that delay be nonvariable to avoid jitter. Real-time traffic, such as video, could
introduce variation in delay, thereby thwarting the steadiness of delay required for successful
voice traffic transmission.
When the priority command is specified for a class, it takes a bandwidth argument that gives
maximum bandwidth in kbps. This parameter specifies the maximum amount of bandwidth
allocated for packets belonging to the class configured. The bandwidth parameter both guar-
antees bandwidth to the priority class and restrains the flow of packets from the priority class.
In the event of congestion, policing is used to drop packets when the bandwidth is exceeded.
Voice traffic queued to the priority queue is UDP-based and therefore is not adaptive to the
early packet drop characteristic of WRED. Because WRED is ineffective, the WRED random-
detect command cannot be used with the priority command. In addition, because policing is
used to drop packets and a queue limit is not imposed, the queue-limit command cannot be
used with the priority command.

Lab 8.9.7 Configuring Low Latency Queuing (LLQ)


In this lab, LLQ enables the use of a single, strict-priority queue within CBWFQ at
the class level.

Configuring LLQ
To give priority to a class within a policy map, use the policy map class configuration mode
command priority bandwidth, which offers the following benefits:
■ It adds strict priority queuing to CBWFQ.
■ It offers better treatment for delay-sensitive data, such as voice over IP.
■ It’s very useful on slow links.
■ It’s also called priority queuing/CBWFQ.
Example 8-27 shows the configuration for a policy map that provides 80 kbps for the traffic
class llqtraffic.

Example 8-27 CBWFQ with a Priority Queue: LLQ

Router(config)#class-map llqtraffic
Router(config-cmap)#exit
Router(config)#policy-map prioritybw
Router(config-pmap)#class llqtraffic

continues
1439_CCNP_3.book Page 528 Wednesday, October 27, 2004 9:54 AM

528 Chapter 8: Quality of Service

Example 8-27 CBWFQ with a Priority Queue: LLQ (Continued)

Router(config-pmap-c)#priority 80
Router(config-pmap)#class class-default
Router(config-pmap-c)#fair-queue
Router(config-pmap-c)#exit

The configuration and operation of LLQ can be verified with the following commands:
■ debug priority—Displays priority queuing output if packets are dropped from the
priority queue.
■ show queue interface-type interface-number—Displays the queuing configuration and
statistics for a particular interface.
■ show policy-map interface interface-name—Displays the configuration of all classes
configured for all traffic policies on the specified interface. Tells you whether packets
and bytes were discarded or dropped for the priority class in the traffic policy attached
to the interface.

Traffic Shaping
Traffic shaping allows rate control of traffic leaving an interface to match its flow to the
speed of the remote target interface and to ensure that the traffic conforms to policies defined
for it. Therefore, traffic adhering to a particular profile can be shaped to meet downstream
requirements, eliminating bottlenecks in topologies with data-rate mismatches.
Traffic shaping prevents packet loss. Its use is important in Frame Relay networks, because a
Frame Relay switch cannot determine which packets take precedence and which packets
should be dropped when congestion occurs. Traffic shaping is of critical importance for real-
time traffic, such as voice over Frame Relay. Latency must be minimized by bounding the
amount of traffic and traffic loss in the data-link network and by keeping the data in the router
that is making the guarantees.
Retaining the data in the router through the use of queuing allows the router to prioritize traf-
fic according to the guarantees it is making.
Cisco IOS QoS software has three types of traffic shaping:
■ Generic Traffic Shaping (GTS)
■ Class-based
■ Frame Relay Traffic Shaping (FRTS)
1439_CCNP_3.book Page 529 Wednesday, October 27, 2004 9:54 AM

Traffic Shaping 529

All three of these traffic-shaping methods are similar in implementation, although the CLIs
differ somewhat and they use different types of queues to contain and shape traffic that is
deferred. The underlying code that determines whether enough credit is in the token bucket
for a packet to be sent or whether that packet must be delayed is common to each feature.
If a packet is deferred, GTS and class-based shaping use a weighted fair queue to hold the
delayed traffic. FRTS uses either a custom queue or a priority queue for the same, depending
on what has been configured.

More Information
The remainder of this section focuses on GTS.
For further information on class-based shaping, refer to http://www.cisco.com/univercd/cc/td/
doc/product/software/ios122/122cgcr/fqos_c/fqcprt4/qcfcbshp.htm.
For more information on Frame Relay traffic shaping, see http://www.cisco.com/univercd/cc/td/
doc/product/software/ios122/122cgcr/fwan_c/wcffrely.htm#wp1001623.

Generic Traffic Shaping (GTS)


Traffic shaping lets you control traffic going out an interface to match its transmission to the
speed of the remote target interface and to ensure that the traffic conforms to the policies
contracted for it. Traffic adhering to a particular profile can be shaped to meet downstream
requirements, thereby eliminating bottlenecks in topologies with data-rate mismatches.
Generic Traffic Shaping (GTS) shapes traffic by reducing outbound traffic flow to avoid con-
gestion by constraining traffic to a particular bit rate using the token bucket mechanism, as
shown in Figure 8-24.

Figure 8-24 GTS Constrains Traffic Using the Token Bucket Mechanism

Match

Token
Bucket Transmit Outgoing
Queue Packets
Incoming
Configured
Packets Classify Rate
WFQ
Weighted Fair
WFQ Is the Scheduling
Only Supported
Token Queuing Method
Bucket

No Match
Classification by
Extended Access “Token Bucket”
List Functionality Shaping
1439_CCNP_3.book Page 530 Wednesday, October 27, 2004 9:54 AM

530 Chapter 8: Quality of Service

GTS is applied on a per-interface basis and can use access lists to select the traffic to shape.
GTS works with a variety of Layer 2 technologies, including
■ Frame Relay
■ ATM
■ Switched Multimegabit Data Service (SMDS)
■ Ethernet
On a Frame Relay subinterface, you can set up GTS to adapt dynamically to available band-
width by integrating Backward Explicit Congestion Notification (BECN) signals, or simply
to shape to a specified rate.
A service provider can use GTS to define the data rate independently of the physical link
clock rate. An ISP might provide customers with a physical T1, regardless of the data rate
they are paying for. The actual rate supplied can then be 128 kbps, configured using GTS. If
the customer wants to upgrade to a 1-Mbps service, this can be achieved with a minor config-
uration change.

Configuring GTS for an Interface


GTS can be configured to shape traffic for all traffic exiting an interface using the following
interface command:
traffic-shape rate bit-rate [burst-size [excess-burst-size]]

Alternatively, traffic defined by an ACL can be shaped independently of other traffic exiting
an interface using the following interface command:
traffic-shape group access-list-number bit-rate [burst-size [excess-burst-size]]

The bit-rate determines the average data rate that is permitted out of the specified interface.
The burst-size is the number of bits that can be sent as a single burst within a time period. The
instantaneous bit-rate can be much higher than the average bit rate. The burst-size should be
configured so that any peaks do not overwhelm the input queue of the destination interface.
The time period (Tc) over which the bit rate is measured is given by this formula:
Tc = burst size / bit rate

From this formula, you can deduce that the smaller the burst size, the shorter the measure-
ment time period, and consequently the smoother, or less bursty, the traffic flow. A small Tc
also ensures more consistent latency, which is important for voice. For voice applications, Tc
should be as small as possible—about 10 ms. This implies that the burst size should be no
more than one one-hundredth of the average bit rate.
The excess-burst-size allows more traffic to be sent in a given time interval than the burst-size
would allow if in a previous time period the maximum amount was not sent. Whenever less
1439_CCNP_3.book Page 531 Wednesday, October 27, 2004 9:54 AM

Traffic Shaping 531

than the burst-size is sent during an interval, the remaining number of bits, up to the excess-
burst-size, can be used to send more than the burst size in a later interval. Configuring the
excess-burst-size to be the same as the burst-size effectively disables any excess burst capa-
bility. Example 8-28 demonstrates traffic shaping configuration on an interface.

Example 8-28 Interface Ethernet 0 Is Configured to Limit UDP Traffic to 1 Mbps, and Interface Ethernet 1 Is
Configured to Limit All Output to 5 Mbps

access-list 101 permit udp any any


interface Ethernet0
traffic-shape group 101 1000000 125000 125000
!
interface Ethernet1
traffic-shape rate 5000000 625000 625000

GTS for Frame Relay Networks


User-specified traffic shaping can be performed on a Frame Relay interface or subinterface
with the traffic-shape rate command. The traffic-shape adaptive command can be specified
to allow the shape of the traffic to dynamically adjust to congestion experienced by the Frame
Relay provider. This is achieved through the receipt of BECNs from the Frame Relay switch.
When a Frame Relay switch becomes congested, it sends BECNs in the direction the traffic
is coming from, and it generates FECNs in the direction the traffic is flowing to.
If the traffic-shape fecn-adapt command is configured at both ends of the link, as shown in
Example 8-29, the far end reflects FECNs as BECNs. BECNs tell the sender to decrease the
transmission rate. If the traffic is one-way only, such as multicast traffic, there is no reverse
traffic with BECNs to notify the sender to slow down. Therefore, when a data terminal equip-
ment (DTE) device receives a FECN, it first determines if it is sending any data in return. If it
is sending return data, this data gets marked with a BECN on its way to the other DTE device.
However, if the DTE device is not sending any data, it can send a Q.922 TEST RESPONSE
message with the BECN bit set.

Example 8-29 In the Presence of BECN Bits from the Network, the Flow Is Throttled Back to the Committed
Information Rate of 64 kbps

interface serial 2
traffic-shape rate 1544000
traffic-shape adaptive 64000
traffic-shape fecn-adapt
1439_CCNP_3.book Page 532 Wednesday, October 27, 2004 9:54 AM

532 Chapter 8: Quality of Service

Configuring GTS for Frame Relay Networks


The following interface commands are used to configure GTS in a Frame Relay environment
(as shown in Example 8-29):
■ traffic-shape rate bit-rate [burst-size [excess-burst-size]]—The standard GTS configu-
ration command that can be applied to any interface to enable outbound traffic shaping.
■ traffic-shape adaptive [bit-rate]—Configures the minimum bit rate that traffic is
shaped to when BECNs are received on an interface. It is common to set this to the
committed information rate (CIR) of the Frame Relay link.
■ traffic-shape fecn-adapt—Configures the reflection of BECN signals as FECNs are
received.
With adaptive GTS, the router uses BECNs to estimate the available bandwidth and adjust the
transmission rate accordingly. The actual maximum transmission rate is between the rate
specified in the traffic-shape adaptive command and the rate specified in the traffic-shape
rate command.

Verifying GTS Configuration


The following commands can be used to verify the configuration and operation of GTS:
■ show traffic-shape
■ show traffic-shape statistics
Examples 8-30 and 8-31 demonstrate sample output from each of these commands.

Example 8-30 Verifying GTS Configuration with the show traffic-shape Command

Router#show traffic-shape
Access Target Byte Sustain Excess Interval Increment Adapt
I/F List Rate Limit bits/int bits/int (ms) (bytes) Active
Fa0/0 101 1000000 31250 125000 125000 125 15625 -
Fa0/1 5000000 156250 625000 625000 125 78125 -

Example 8-31 Displaying GTS Statistics with the show traffic-shape statistics Command

Router#show traffic-shape statistics


Access Queue Packets Bytes Packets Bytes Shaping
I/F List Depth Delayed Delayed Active
Fa0/0 101 0 0 0 0 0 no
Fa0/1 0 0 0 0 0 no
1439_CCNP_3.book Page 533 Wednesday, October 27, 2004 9:54 AM

QoS Using Low-Speed Links 533

Lab 8.9.8 Configuring Generic Traffic Shaping (GTS)


In this lab, you configure GTS on an interface.

Lab 8.9.9 QoS Manually Configured Frame Relay Traffic Shaping


In this lab, you use FRTS to shape traffic exiting a Frame Relay interface so that it
matches the CIR, Bc, and Be provided by the ISP.

Lab 8.9.10 QoS Dynamically Configured Frame Relay Traffic Shaping


In this lab, you use Dynamic FRTS to shape traffic exiting a Frame Relay interface
such that the traffic flow responds to BECNs received from the Frame Relay switch.

QoS Using Low-Speed Links


Up to this point, QoS issues within a switched LAN environment have been considered.
Some traffic needs to find its way across lower-speed WAN links. Although many of the QoS
features explored in the LAN environment can be applied in the WAN, low-bandwidth WAN
links are significant contributors to latency and require special attention. Figure 8-25 illus-
trates several low-speed WAN links. Figure 8-26 illustrates dial-up connections.

Figure 8-25 QoS Is Just as Important on Low-Speed WAN Links As Anywhere Else in a Network

WAN Concentration
Multiple T1 and Frame Relay Links

Primary WAN
Regional
FR X.25 LL Center

HQ Cisco 3640
ISDN
PSTN

Backup WAN
1439_CCNP_3.book Page 534 Wednesday, October 27, 2004 9:54 AM

534 Chapter 8: Quality of Service

Figure 8-26 Terminal Server and Remote-Access Applications Enjoy the Benefits of QoS

Terminal Server/
Remote Access Applications
Up to 96 Ports

PSTN
To HQ

Cisco 3640

LAN

Link Efficiency Mechanisms


A significant problem associated with low-speed WAN links is the possibility of vital traffic
becoming trapped behind streams of less-important traffic. Link efficiency mechanisms can
be used to give priority to one class of traffic over another. WFQ is one such mechanism that
can be used to reduce the latency for low-volume traffic streams. However, if the WAN band-
width is very low, even being trapped behind a single large packet might introduce too much
latency for delay-sensitive voice traffic.

Link Fragmentation and Interleaving (LFI)


In addition to network congestion, one of the primary contributors to both delay and jitter is
serialization delay, which is often caused by a time-sensitive packet getting “stuck in traffic”
behind a large data packet, such as FTP. The lower the link’s speed, the more significant the
serialization delay, as shown in Table 8-5.
Link fragmentation is the process of breaking up large packets to allow smaller, more time-
sensitive packets to proceed through the network in a timely manner. Interleaving is the pro-
cess of “weaving” time-sensitive packets into the train of fragmented data packets, as shown
in Figure 8-27—thus, the term Link Fragmentation and Interleaving (LFI).
1439_CCNP_3.book Page 535 Wednesday, October 27, 2004 9:54 AM

QoS Using Low-Speed Links 535

Table 8-5 Serialization Delay Is the Frame Size in Bits Divided by the Link Bandwidth in Bits
Per Second

64 128 256 512 1024 1500


1 Byte Bytes Bytes Bytes Bytes Bytes Bytes

56 kbps 143 µs 9 ms 18 ms 36 ms 72 ms 144 ms 214 ms

64 kbps 125 µs 8 ms 16 ms 32 ms 64 ms 126 ms 187 ms

128 kbps 62.5 µs 4 ms 8 ms 16 ms 32 ms 64 ms 93 ms

256 kbps 31 µs 2 ms 4 ms 8 ms 16 ms 32 ms 46 ms

512 kbps 15.5 µs 1 ms 2 ms 4 ms 8 ms 16 ms 32 ms


768 kbps 10 µs 640 µs 1.28 ms 2.56 ms 5.12 ms 10.24 ms 15 ms

1536 kbps 5 µs 320 µs 640 µs 1.28 ms 2.56 ms 5.12 ms 7.5 ms

Figure 8-27 LFI Breaks Up Large Packets and Weaves Them into the Train of Fragmented Data

Large Packet
Fragmentation: Transmit Output
Traffic Fragment Size Based Queue Line
Destined for on Required Delay
Interface

Jumbogram/
IP Voice



Multiple PPP Per Flow •
with LFI on Classification WFQ

Link Fragmentation and Interleaving (LFI): Multilink PPP


Although 1500 bytes is a common size for data packets, a typical VoIP packet carrying G.729
voice frames can be about 66 bytes—20 bytes voice payload, 6 bytes Layer 2 header, 20 bytes
RTP and UDP header, and 20 bytes IP header.
Now imagine a 56-kbps leased line link where voice and data traffic coexist. If a voice packet
is ready to be serialized just when a data packet starts being transmitted over the link, a prob-
lem occurs. The delay-sensitive voice packet has to wait 214 ms before being transmitted.
1439_CCNP_3.book Page 536 Wednesday, October 27, 2004 9:54 AM

536 Chapter 8: Quality of Service

Large data packets can delay the delivery of small voice packets, reducing speech quality.
Fragmenting these large data packets into smaller ones and interleaving voice packets among
the fragments reduces jitter and delay. The Cisco IOS LFI feature helps satisfy the real-time
delivery requirements of VoIP on a multilink PPP link, as shown in Figure 8-28.

NOTE Figure 8-28 LFI Can Work in Conjunction with Multilink PPP
In cases with a WAN
link of more than Large Packet
768 kbps, the frag- Fragmentation: Transmit Output
Traffic Fragment Size Based Queue Line
mentation feature is Destined for on Required Delay
unneeded. However, Interface
there is still a need for
some type of QoS Jumbogram/
IP Voice
mechanism, such as
LLQ or IP RTP Priority.
Seven hundred sixty- •

eight kbps offers Multiple PPP Per Flow •
enough bandwidth to with LFI on Classification WFQ
allow voice packets
to enter and leave the
queue without delay
issues. The amount of serialization delay (the time it takes to place the bits on an interface) intro-
duced on low-speed WAN links can be significant, particularly when you consider that the
target end-to-end one-way delay should not exceed 150 ms. For voice applications, the rec-
ommended serialization delay, on a per-hop basis, is 10 ms and should not exceed 20 ms.

Lab 8.9.11 Link Fragmentation and Interleaving


In this lab, you configure LFI to control latency over a low-speed WAN link.

Compressed Real-Time Protocol (CRTP)


RTP is the Internet-standard protocol for the transport of real-time data, including audio and
video. It can be used for media on demand as well as interactive services, such as Internet
telephony. RTP consists of a data part and a control part, called Real-Time Control Protocol
(RTCP). The data part of RTP is a thin protocol that provides support for applications with
real-time properties such as continuous media, audio and video, timing reconstruction, loss
detection, and content identification.
Compressed Real-Time Transport Protocol (CRTP) is used on a link-by-link basis to com-
press the IP/UDP/RTP header. In a packet voice environment when framing speech samples
every 20 ms, this scenario generates a payload of 20 bytes. The total packet size is made up of
the following:
■ An IP header of 20 bytes
■ A UDP header of 8 bytes
1439_CCNP_3.book Page 537 Wednesday, October 27, 2004 9:54 AM

QoS Using Low-Speed Links 537

■ An RTP header of 12 bytes


■ A payload of 20 bytes
It is evident that the header size is twice the size of the payload. When generating packets NOTE
every 20 ms on a slow link, the header consumes a large portion of the bandwidth. To avoid Cisco recommends
using CRTP only with
the unnecessary consumption of available bandwidth, CRTP is used on a link-by-link basis.
links lower than 768
This compression scheme, illustrated in Figure 8-29, reduces the IP/UDP/RTP header to 2 bytes kbps, unless the router
is running at a low CPU
most of the time when no UDP checksums are being sent or to 4 bytes when UDP checksums utilization rate. Monitor
are used. the router CPU utiliza-
tion and disable CRTP
if it is above 75%. If
Figure 8-29 CRTP Efficiently Compresses IP/UDP/RTP Header Combinations
CRTP needs to be dis-
abled, it is likely that a
higher-performance
Transmit Output
Traffic RTP Traffic Queue Line router or additional
Destined for (Video, Audio, etc.) capacity is required.
Interface
Classify RTP
Compressor




Identify RTP Configured Output
Traffic Compression Queuing

12 8 20

RTP UDP IPH IP Data

IP Data
5

Efficiencies Payload Packet Size Reduction*

VoIP 20 Bytes ~240%

SQL Queuing 256 Bytes ~13%

FTP 1500 Bytes ~2.3%

*Also -5 ms Reduction in Serialization Delay at 64 kbps

Configuring CRTP
CRTP is a hop-by-hop compression scheme. It must be configured on both ends of the link,
unless the passive option is configured. A typical implementation involves a Frame Relay
permanent virtual circuit (PVC), as shown in Figure 8-30.
1439_CCNP_3.book Page 538 Wednesday, October 27, 2004 9:54 AM

538 Chapter 8: Quality of Service

Figure 8-30 CRTP Is a Hop-by-Hop Compression Scheme

Frame-Relay

1/1 2/1
128 kbps
s0/0 CIR s0/0
DLCI 102 DLCI 201
Singapore .1 .2 SanJose 1
192.168.2.0/24
fa0/0 .1 fa0/0 .1

192.168.1.0/24 192.168.3.0/24

NOTE To configure CRTP, use the interface command ip rtp header-compression [passive].
When the command ip
rtp header-compres-
To compress the TCP headers without enabling CRTP, use the interface command ip tcp
sion is used, the router header-compression [passive].
adds the command ip
tcp header-compres- CRTP is not required to ensure good voice quality. It is a feature that reduces bandwidth con-
sion to the configura- sumption. Configure CRTP after all other conditions are met, and the voice quality is good.
tion by default. This is
used to compress the This procedure can save you troubleshooting time by isolating potential CRTP issues.
headers of TCP/IP
packets. Header com-
pression is particularly Lab 8.9.12 QoS Compressed Real-Time Protocol
useful on networks with In this lab, you configure CRTP if the network has slow links and bandwidth needs to
a large percentage of
small packets, such as be saved.
those supporting many
Telnet connections. The
TCP header compres-
sion technique is sup-
ported on serial lines Summary
using HDLC or PPP
encapsulation. This chapter outlined the components of QoS and the IOS mechanisms for delivering end-to-
end QoS through classification, marking, policing, traffic shaping, and link efficiency mecha-
nisms. Although the general principles for implementing QoS are quite straightforward, there
are many types of QoS, and sometimes several can be used in combination. In many cases,
QoS features are specific to the Cisco hardware platform.
1439_CCNP_3.book Page 539 Wednesday, October 27, 2004 9:54 AM

Key Terms 539

Key Terms
class of service (CoS) 802.1Q frame headers have a 2-byte Tag Control Information field
that carries the CoS value in the 3 most-significant bits. Layer 2 CoS values range from 0 for
low priority to 7 for high priority. CoS is used with QoS, especially at the network’s access
layer.
class-based traffic shaping Allows you to control the traffic going out an interface to match
its transmission to the speed of the remote, target interface and to ensure that the traffic con-
forms to policies contracted for it. Traffic adhering to a particular profile can be shaped to
meet downstream requirements, thereby eliminating bottlenecks in topologies with data-rate
mismatches. Can be enabled on any interface that supports GTS.
Class-Based Weighted Fair Queuing (CBWFQ) Extends the standard WFQ functionality
to provide support for user-defined traffic classes. For CBWFQ, you define traffic classes
based on match criteria including protocols, access control lists (ACLs), and input interfaces.
Packets satisfying the match criteria for a class constitute the traffic for that class. A FIFO
queue is reserved for each class, and traffic belonging to a class is directed to the queue for
that class.
Committed Access Rate (CAR) A rate-limiting feature for policing traffic. It manages a net-
work’s access bandwidth policy by ensuring that traffic falling within specified rate parame-
ters is sent, while dropping packets that exceed the acceptable amount of traffic or sending
them with a different priority. The exceed action for CAR is to drop or mark down packets.
Compressed Real-Time Transport Protocol (CRTP) An RTP header compression feature
used on a link-by-link basis.
delay Also known as latency. Refers to the time it takes a packet to travel from the source to
the destination.
delay variation See jitter.
Differentiated Services Code Point (DSCP) The first 6 bits of the ToS field. Used to clas-
sify IP traffic.
Frame Relay Traffic Shaping (FRTS) Eliminates bottlenecks in Frame Relay networks
that have high-speed connections at the central site and low-speed connections at branch
sites. You configure rate enforcement, a peak rate configured to limit outbound traffic, to limit
the rate at which data is sent on the VC at the central site. Using FRTS, you can configure rate
enforcement to either the CIR or some other defined value, such as the excess information
rate, on a per-VC basis. The ability to allow the transmission speed used by the router to be
controlled by criteria other than line speed (that is, by the CIR or the excess information rate)
provides a mechanism for multiple VCs to share media. You can allocate bandwidth to each
VC, creating a virtual time-division multiplexing (TDM) network.
1439_CCNP_3.book Page 540 Wednesday, October 27, 2004 9:54 AM

540 Chapter 8: Quality of Service

Generic Traffic Shaping (GTS) Shapes traffic by reducing outbound traffic flow to avoid
congestion by constraining traffic to a particular bit rate using the token bucket mechanism.
GTS applies on a per-interface basis and can use access lists to select the traffic to shape. It
works with a variety of Layer 2 technologies, including Frame Relay.
IP Precedence 3 bits in the ToS field of the IP header used to specify a packet’s class of
service.
jitter Also known as delay variation. The difference in the delay times of consecutive
packets.
latency See delay.
Link Fragmentation and Interleaving (LFI) A feature that reduces delay on slower-speed
links by breaking up large datagrams and interleaving low-delay traffic packets with the
smaller packets resulting from the fragmented datagram.
loss The percentage of packets that fail to reach their destination.
Low Latency Queuing (LLQ) Brings strict priority queuing to CBWFQ. Strict priority
queuing allows delay-sensitive data, such as voice, to be dequeued and sent first (before pack-
ets in other queues are dequeued), giving delay-sensitive data preferential treatment over
other traffic.
scheduling The process of assigning packets to one of multiple queues, based on classifica-
tion, for priority treatment through the network.
type of service (ToS) A 1-byte field in the IP header used for traffic classification. Specifies
the parameters for the type of service requested. Networks can use the parameters to define
the handling of the datagram during transport.
Weighted Fair Queuing (WFQ) A dynamic scheduling method that provides fair band-
width allocation to all network traffic. WFQ applies priority, or weights, to identified traffic to
classify traffic into conversations and to determine how much bandwidth each conversation is
allowed relative to other conversations. WFQ is a flow-based algorithm that simultaneously
schedules interactive traffic to the front of a queue to reduce response time. It fairly shares the
remaining bandwidth among high-bandwidth flows.
Weighted Random Early Detection (WRED) A mechanism designed to avoid the global
synchronization problems that occur when tail-drop is used as the congestion avoidance
mechanism on the router. WRED is a queuing technique for congestion avoidance. WRED
manages how packets are handled when an interface starts becoming congested. When traffic
begins to exceed the interface traffic thresholds before any congestion, the interface starts
1439_CCNP_3.book Page 541 Wednesday, October 27, 2004 9:54 AM

Check Your Understanding 541

dropping packets from selected flows. If the dropped packets are TCP, the TCP source recog-
nizes that packets are getting dropped and lowers its transmission rate. The lowered transmis-
sion rate then reduces the traffic to the interface, avoiding congestion. Because TCP
retransmits dropped packets, no actual data loss occurs.

Check Your Understanding


Use the following review questions to test your understanding of the concepts covered in this
chapter. Answers are listed in Appendix A, “Check Your Understanding Answer Key.”
1. What QoS characteristics define the quality of the movement of traffic from one point
to another?
A. Bandwidth

B. Jitter

C. Loss

D. Delay
2. Loss for voice traffic should not exceed what percentage?

A. .5 percent

B. 1 percent

C. 2 percent

D. 4 percent
3. Latency for video traffic should be no more than how many seconds?

A. 2 to 3 seconds

B. 3 to 4 seconds

C. 4 to 5 seconds

D. 5 to 6 seconds
4. Which of the following are the three QoS service models?

A. Deterministic

B. Best-effort

C. DiffServ

D. IntServ
1439_CCNP_3.book Page 542 Wednesday, October 27, 2004 9:54 AM

542 Chapter 8: Quality of Service

5. How many bits are used to indicate IP Precedence?

A. 2

B. 3

C. 6

D. 8
6. How many bits are used to indicate IP DSCP?

A. 2

B. 3

C. 6

D. 8
7. The CoS is set to which of the following values on traffic sourced by a Cisco IP Phone?

A. 0

B. 1

C. 5

D. 7
8. What type of QoS is used to prevent tail drop from causing traffic irregularities?

A. RSVP

B. GTS

C. WRED

D. CAR
9. Where in a network should traffic be marked? (Select all that apply.)

A. Edge router

B. Core router

C. Access router

D. Distribution router
10. What type of queuing is designed specifically for voice traffic?

A. CBWFQ

B. FIFO

C. WFQ

D. LLQ
1439_CCNP_3.book Page 543 Wednesday, October 27, 2004 9:54 AM
1439_CCNP_3.book Page 544 Monday, November 15, 2004 10:35 AM

Objectives
After completing this chapter, you will be able to perform tasks related to the following:
■ Understand and configure Switched Port Analyzer (SPAN), VLAN-based Switched
Port Analyzer (VSPAN), and Remote Switched Port Analyzer (RSPAN).
■ Understand the role and implementation of the Network Analysis Module (NAM).
■ Understand the role and implementation of the Switch Fabric Module (SFM).
■ Explain access control policy.
■ Configure password protection, privilege levels, and remote-access restrictions.
■ Configure Secure Shell (SSH).
■ Configure virtual LAN (VLAN) maps.
■ Configure router access control lists (ACLs) and port ACLs.
■ Configure port security and protected ports.
■ Configure authentication, authorization, and accounting (AAA) with Terminal Access
Controller Access Control System Plus (TACACS+) and Remote Authentication Dial-In
User Service (RADIUS).
■ Understand 802.1x port-based authentication.
1439_CCNP_3.book Page 545 Monday, November 15, 2004 10:35 AM

Chapter 9

Monitoring and Security


This chapter covers two main areas:
■ The first part discusses mechanisms for monitoring traffic in a multilayer switched net-
work using the Cisco Switched Port Analyzer (SPAN) feature set. This discussion includes
the following topics:
— How to use VLAN-based Switched Port Analyzer (VSPAN) to monitor traffic in a
VLAN
— How to use Remote Switched Port Analyzer (RSPAN) to monitor traffic across
multiple switches
— How to use the Network Analysis Module (NAM) and Switch Fabric Module (SFM)
to improve switch monitoring and performance
■ The second part discusses securing devices in a multilayer switched network. Topics
discussed in this part include the following:
— Security concepts
— Security and remote device management
— Technologies available for controlling user traffic

Monitoring Switched Network Performance with SPAN


and VSPAN
SPAN is a method of monitoring network traffic by copying source port or VLAN-specific traffic
to a destination port for analysis. Figure 9-1 illustrates a SPAN in which all traffic on port 5, the
source port, is mirrored to port 10, the destination port. A network analyzer on port 10 receives
all network traffic from port 5 without being physically attached to port 5.
1439_CCNP_3.book Page 546 Monday, November 15, 2004 10:35 AM

546 Chapter 9: Monitoring and Security

Figure 9-1 SPAN in Action

1 2 3 4 5 6 7 8 9 10 11 12
Port 5 Traffic
Mirrored on Port 10

6 7
5 8 11
4 9 12
3 10
2

1 Network Analyzer

VLAN-based SPAN (VSPAN) is the analysis of the network traffic in one or more VLANs.
You can configure VSPAN to monitor only received traffic, which applies to all the ports for
that VLAN.
SPAN can be used to monitor all network traffic, including
■ Multicast and Bridge Protocol Data Unit (BPDU) frames
■ Cisco Discovery Protocol (CDP) frames
■ VLAN Trunking Protocol (VTP) frames
■ Dynamic Trunking Protocol (DTP) frames
■ Spanning Tree Protocol (STP) frames
■ Port Aggregation Protocol (PAgP) frames
In some SPAN configurations, multiple copies of the same source packet are sent to the
SPAN destination port. For example, suppose a bidirectional SPAN session is configured
for sources a1 and a2 to destination port d1, as shown in Figure 9-2. A bidirectional SPAN
session monitors both incoming and outgoing traffic for a port. If a packet enters the switch
through a1 and gets switched to a2, both incoming and outgoing packets are sent to destina-
tion port d1. In this case, both packets are the same. However, if the data is re-encapsulated at
Layer 3, the frames are different.

Monitoring with SPAN on a Port Basis


SPAN can be used to analyze network traffic passing through ports. This occurs by sending
a copy of the traffic to a destination port on the switch that has been connected to a network
analyzer or protocol analyzer. SPAN can be used to mirror traffic for later analysis. Mirrored
traffic is all traffic sent to and/or received from one or more SPAN source ports defined in the
SPAN configuration.
1439_CCNP_3.book Page 547 Monday, November 15, 2004 10:35 AM

Monitoring Switched Network Performance with SPAN and VSPAN 547

Figure 9-2 The Destination Port Sees Multiple Copies of Frames When Unicast Traffic Passes
Between Two SPAN Source Ports
Switched Traffic

Mirrored Traffic (Monitored)

1 2 1

Switching Fabric
1 1 2

Port a1 Port a2 Unmonitored Path Port d1

Switch 1

1 2 2

1
1 2

Remote
Monitor
(RMON)

SPAN does not affect the switching of network traffic on source ports, although it might
affect the behavior of some features on source and destination ports. A copy of the packets
received or sent by the source interfaces is sent to the destination interface. The only traffic
sent or received by SPAN destination ports is related to the SPAN process.
A source port is a Layer 2 or Layer 3 port from which the SPAN process copies traffic. Data
forwarded from a SPAN source port to a SPAN destination port can include all frames trans-
mitted by the port and/or all frames received by the port.
A SPAN destination port is a Layer 2 or Layer 3 port to which the SPAN process copies traffic.
When a port is configured as a SPAN destination port, it can no longer forward any traffic
other than SPAN traffic, and it becomes dedicated for use by the SPAN process. A SPAN
destination port does not forward any traffic except that required for the SPAN session.
Beginning with switch Cisco IOS Release 12.1(13)E, trunk ports can be configured as SPAN
destination ports. This allows SPAN destination ports to transmit traffic encapsulated for mul-
tiple VLANs. With earlier switch IOS releases, a trunk port automatically reverted to access
mode when configured as a SPAN destination port.
1439_CCNP_3.book Page 548 Monday, November 15, 2004 10:35 AM

548 Chapter 9: Monitoring and Security

SPAN Interaction with Other Features


SPAN might affect the behavior of features configured on source and destination ports. SPAN
disables some destination port features, which are restored when the SPAN session is
removed from the switch. Table 9-1 summarizes the features and interactions.

Table 9-1 SPAN Does Not Work Seamlessly with Some LAN Switch Technologies

Feature SPAN Interaction

Change in VLAN Not applied until the session is disabled.


membership

Trunk settings Not applied until the session is disabled.

EtherChannel groups Cannot become a SPAN destination.

EtherChannel port Removed from the EtherChannel group for the duration of the
members SPAN session.
QoS-classified traffic Packets could differ from source port ingress traffic. The desti-
nation port receives packets after classification and policing.

Multicast traffic Only a single, unedited packet is sent to the destination port,
not one for each multicast session member.

SPAN Interaction with VLANs and CDP


Changes in VLAN membership can be made, but they are not applied to SPAN destination
ports. For source ports, VLAN or trunk settings take effect immediately, and the SPAN ses-
sion automatically adjusts accordingly.
A SPAN destination port does not participate in CDP.

SPAN Interaction with an EtherChannel Member or Trunked Port


If a port is added to a monitored EtherChannel group, it is added to the SPAN source port list.
If a port is removed from a monitored EtherChannel group, it is automatically removed from
the source port list.
An EtherChannel group can be configured as a source port, but not as a SPAN destination
port. When a group is configured as a SPAN source, the entire group is monitored.
VLAN membership or trunk settings can be modified for source or destination ports at any
time. However, changes in VLAN membership or trunk settings for a destination port do not
take effect until the SPAN session is disabled.
1439_CCNP_3.book Page 549 Monday, November 15, 2004 10:35 AM

Monitoring Switched Network Performance with SPAN and VSPAN 549

If a physical port that belongs to an EtherChannel group is configured as a SPAN source or


destination port, that port is removed from the group. After the port is removed from the
SPAN session, it rejoins the EtherChannel group. Ports removed from an EtherChannel group
remain members of the group, but they are in the down or standalone state.
If a physical port that belongs to an EtherChannel group is a destination port and the Ether-
Channel group is a source, the port is removed from the EtherChannel group and from the list
of monitored ports.

SPAN Interaction with QoS Classified and Multicast Traffic


For ingress, or incoming, traffic monitoring, the packets sent to the SPAN destination port
might be different from the packets actually received at the SPAN source port. The packets
are forwarded after ingress QoS classification and policing. The Differentiated Services Code
Point (DSCP) value of the sent packet might not be the same as that for the received packet.
Multicast traffic can be monitored. For egress (or outgoing) traffic and ingress port monitor-
ing, only a single unedited packet is sent to the SPAN destination port.
A port with port security configured on it cannot be a SPAN destination port. Port security is
discussed in the section “Using Port Security, Protected Ports, and Private VLANs.”

SPAN Configuration Limitations


Only one local SPAN session can be configured and stored in nonvolatile random-access
memory (NVRAM) on a Catalyst 2950 switch.
Consider the following issues when configuring SPAN or VSPAN:
■ A port cannot double as a destination port and a source port. It must be one or the other.
■ An EtherChannel port can be only a SPAN source port.
■ For SPAN source ports, sent and received traffic can be monitored for a single port or
for a range of ports.
■ A switch port configured as a SPAN destination port is no longer a normal switch port.
Only monitored traffic passes through the SPAN destination port.
■ A SPAN destination port does not participate in any VLAN spanning tree, although
spanning-tree BPDUs on source ports or VLAN traffic are copied to SPAN destination
ports.
A Catalyst 3550 or Catalyst 6500 can have two local SPAN sessions with two different desti-
nation ports. Also, with these switches, a source port can be included in two different sessions
and monitored by two different destination ports.
1439_CCNP_3.book Page 550 Monday, November 15, 2004 10:35 AM

550 Chapter 9: Monitoring and Security

Configuring SPAN Sessions


The procedure to create a SPAN session and specify the source (or monitored) port and the
destination (or monitoring) port is relatively simple, as shown in Table 9-2.

Table 9-2 Configuring SPAN Involves Specifying the Source and Destination Ports

Step Command Description

1 configure terminal Enters global configuration mode.

2 no monitor session {session-number | Clears any existing SPAN configuration


all | local | remote} for the session. Specify all to remove
all SPAN sessions, local to remove all
local sessions, or remote to remove all
remote SPAN sessions.

3 monitor session session-number Specifies the SPAN session and source


source interface interface-id [, | -] port (monitored port). For interface-id,
[both | rx | tx] specify the source port, interface, or
logical interface (port-channel port-
channel-number). The optional key-
words [, | -] specify a series or range of
interfaces.
The optional keywords [both | rx | tx]
specify the direction of traffic to moni-
tor (rx = received; tx = sent). The
default is bidirectional (both).

4 monitor session session-number Specifies the SPAN session and destina-


destination interface interface-id tion port (monitoring port). For inter-
face-id, specify the destination port.
Physical interfaces are valid.
(Optional) Specify the encapsulation
header for outgoing packets.

5 end Returns to privileged EXEC mode.


6 show monitor [session session- Verifies entries.
number]

7 copy running-config startup-config (Optional) Saves entries in the configu-


ration file.

Initially, clear any previous SPAN session from the active configuration:
no monitor session session_number
1439_CCNP_3.book Page 551 Monday, November 15, 2004 10:35 AM

Monitoring Switched Network Performance with SPAN and VSPAN 551

Next, define the source port being monitored:


monitor session session-number source interface interface-id module/interface

Finally, specify the destination port for the mirrored traffic:


monitor session session-number destination interface interface-id NOTE
module/interface [encapsulation {dot1q | isl}] ISL cannot be specified
Example 9-1 shows how to set up a SPAN session, session 1, to monitor source port traffic to on 2950 switches.

a destination port. First, any existing SPAN configuration for session 1 is cleared, and then
bidirectional traffic is mirrored from source port 1 to destination port 10.

Example 9-1 A Basic SPAN Session Is Simple to Set Up

Switch(config)#no monitor session 1


Switch(config)#monitor session 1 source interface fastethernet 0/1
Switch(config)#monitor session 1 destination interface fastethernet 0/10
encapsulation dot1q
Switch(config)#end

Table 9-3 documents how to remove a source port from a SPAN session.

Table 9-3 Removing a SPAN Session Is Straightforward

Step Command Description

1 configure terminal Enters global configuration mode.


2 no monitor session session-number Specifies the characteristics of the
source interface interface-id [, | -] source port (monitored port) and SPAN
[both | rx | tx] session to remove. For interface-id,
specify the source port to no longer
monitor. This operation is valid only
when monitoring received traffic.
The optional keywords [both | rx | tx]
specify the direction of traffic to no
longer monitor. The default is to disable
both rx and tx.

3 end Returns to privileged EXEC mode.

4 show monitor [session session- Verifies entries.


number]

5 copy running-config startup-config (Optional) Saves entries in the configu-


ration file.
1439_CCNP_3.book Page 552 Monday, November 15, 2004 10:35 AM

552 Chapter 9: Monitoring and Security

Example 9-2 shows how to remove source port FastEthernet0/1 from SPAN session 1.

Example 9-2 Removing a Source Port from a SPAN Session

Switch(config)#no monitor session 1 source interface fastethernet 0/1


Switch(config)#end

To remove a destination port from a SPAN session, use the following global configuration
command:
no monitor session session-number destination interface interface-id

Example 9-3 shows how to remove destination port FastEthernet 0/10 from SPAN session 1.

Example 9-3 Removing a Destination Port from a SPAN Session

Switch(config)#no monitor session 1 destination interface fastethernet 0/10


Switch(config)#end

Lab 9.9.1 Creating a Switched Port Analyzer (SPAN) Session


In this lab exercise, you create a SPAN session to remotely monitor network traffic.

VSPAN—SPAN Using VLANs as Monitored Source


SPAN can also be applied on a VLAN basis. A source VLAN is a VLAN monitored for net-
work traffic analysis. VSPAN uses one or more VLANs as the SPAN source. All the ports in
the source VLAN(s) become source ports. For VSPAN, only incoming traffic can be moni-
tored (rx traffic). VSPAN cannot be implemented on 2950 switches.
VLAN monitoring is similar to port monitoring, as shown in Table 9-4.

Table 9-4 SPAN Can Be Used to Monitor All Traffic from One or More VLANs

Step Command Description

1 configure terminal Enters global configuration mode.


2 no monitor session {session-number | Clears any existing SPAN configuration
all | local | remote} for the session. Specify all to remove
all SPAN sessions, local to remove all
local sessions, or remote to remove all
remote SPAN sessions.
1439_CCNP_3.book Page 553 Monday, November 15, 2004 10:35 AM

Monitoring Switched Network Performance with SPAN and VSPAN 553

Table 9-4 SPAN Can Be Used to Monitor All Traffic from One or More VLANs

Step Command Description

3 monitor session session-number Specifies the SPAN session and the


source vlan vlan-id [, | -] rx source VLANs (monitored VLANs).
You can monitor only received (rx)
traffic on VLANs.
(Optional) Use a comma (,) to specify a
series of VLANs, or use a hyphen (-) to
specify a range of VLANs. Enter a
space before and after the comma or
hyphen.
4 monitor session session-number Specifies the SPAN session and the des-
destination interface interface-id tination port (monitoring port).
For interface-id, specify the destination
port. Physical interfaces are valid.

5 end Returns to privileged EXEC mode.

6 show monitor [session session- Verifies entries.


number]

7 copy running-config startup-config (Optional) Saves entries in the configu-


ration file.

First, you clear any previous SPAN session from the active configuration using the no moni-
tor session session_number command.
This is followed by defining the VLANs being monitored using the monitor session session_
number source vlan vlan-id [, | -] rx command. Note that other directions are unavailable for
use when setting a VLAN as the SPAN source.
Finally, you specify a destination port for the mirrored traffic using the command monitor
session session_number destination interface interface-id module/interface [encapsulation
{dot1q | isl}]. Note that ISL cannot be specified on 2950 switches.
Example 9-4 shows how to clear any existing configuration on SPAN session 2, configure
SPAN session 2 to monitor received traffic on all ports belonging to VLANs 1 to 3, and send
it to destination port 7. The configuration is then modified to also monitor received traffic on
all ports belonging to VLAN 10.
1439_CCNP_3.book Page 554 Monday, November 15, 2004 10:35 AM

554 Chapter 9: Monitoring and Security

Example 9-4 Specifying SPAN Source Traffic by VLAN

Switch(config)#no monitor session 2


Switch(config)#monitor session 2 source vlan 1 - 3 rx
Switch(config)#monitor session 2 destination interface gigabitethernet 0/7
Switch(config)#monitor session 2 source vlan 10 rx
Switch(config)#end
Switch#show monitor session 2

To remove one or more source VLANs or destination ports from the SPAN session, use the
following global configuration command:
no monitor session session_number source vlan vlan-id

To remove the destination interface, use the following global configuration command:
no monitor session session_number destination interface interface-id

To display the status of the current SPAN configuration, use the show monitor privileged
EXEC command, as shown in Example 9-5.

Example 9-5 Verifying the SPAN Configuration

Switch#show monitor session 2

Session 2
-------
Source Ports:
RX Only: Gi0/4
TX Only: None
Both: None
Source VLANs:
RX Only: None
TX Only: None
Both: None
Destination Ports: Gi0/8
Encapsulation: Native

Filter VLANs: 1-5.9

Lab 9.9.2 Creating a VSPAN Session


In this lab exercise, you create a VSPAN session to remotely monitor network traffic.
1439_CCNP_3.book Page 555 Monday, November 15, 2004 10:35 AM

RSPAN 555

RSPAN
RSPAN is an implementation of SPAN designed to support source ports, source VLANs, and
destination ports across different switches. RSPAN allows remote monitoring of multiple
switches across a network, as shown in Figure 9-3. An RSPAN requirement is that participat-
ing switches must have the enhanced software image (EI) installed. A significant difference in
RSPAN from SPAN and VSPAN is that RSPAN cannot be used to monitor Layer 2 protocols
including BPDUs.

Figure 9-3 RSPAN Enables the Monitoring of Traffic from Remote Switches

Destination Switch
Switch D (Core)
D1 D2

Probe

C1
Intermediate Switch
Switch C (Distribution)
C3
C2

A1 B1
Source Switch(es)
Switch A Switch B (Access)
A2 A3 B2 B3 B4

The first step in creating an RSPAN session is to create an RSPAN VLAN dedicated to that
particular session in all participating switches.
RSPAN uses reflector ports to be able to reproduce traffic from source ports residing on
remote switches to the destination port on the local switch. Except for traffic that is required
for the RSPAN session, RSPAN reflector ports work just like RSPAN destination ports.
Reflector ports forward only packets received from or sent by source ports. They do not
receive or forward any other network traffic, as shown in Figure 9-4.
RSPAN source ports can be trunks carrying the RSPAN VLAN. Local SPAN and RSPAN do
not monitor the RSPAN traffic in the RSPAN VLAN seen on a source trunk.
RSPAN traffic from source ports or source VLANs is switched to the RSPAN VLAN and is
then forwarded to destination ports that are also in the RSPAN VLAN. The source, port or
VLAN, in an RSPAN session can be different on different source switches. However, if Inter-
net routers, such as the Cisco 7600 series routers, are used as sources for an RSPAN session,
they must have the same VLANs as RSPAN sources.
1439_CCNP_3.book Page 556 Monday, November 15, 2004 10:35 AM

556 Chapter 9: Monitoring and Security

Figure 9-4 Reflector Ports Are Dedicated to Forwarding SPAN Traffic

Source Intermediate Destination


Switch Switch Switch
RSPAN RSPAN
VLAN VLAN

RSPAN Reflector
Source Port Port

Like SPAN, RSPAN does not affect the switching of network traffic on source ports. Copies
of the packets received or sent by the source interfaces are sent to the destination interface.
Except for traffic that is required for the RSPAN session, reflector ports and destination ports
do not receive or forward traffic.

RSPAN Reflector Ports


Reflector ports are used as a mechanism to copy monitored packets onto an RSPAN VLAN.
The reflector port forwards only the traffic from the RSPAN source session with which it is
affiliated. Any device connected to a port set as a reflector port loses connectivity until the
RSPAN source session is disabled.
The reflector port has the following characteristics:
■ It is a port set to loopback.
■ It cannot be an EtherChannel group, it does not trunk, and it cannot do protocol
filtering.
■ It can be a physical port that is assigned to an EtherChannel group, even if the Ether-
Channel group is specified as a SPAN source. The port is removed from the group
while it is configured as a reflector port.
■ A port used as a reflector port cannot be a SPAN source or destination port, nor can a
port be a reflector port for more than one session at a time.
■ It is invisible to all VLANs.
■ The native VLAN for looped-back traffic on a reflector port is the RSPAN VLAN.
■ The reflector port loops back untagged traffic to the switch. The traffic is then placed on
the RSPAN VLAN and flooded to any trunk ports that carry the RSPAN VLAN.
■ STP is automatically disabled on a reflector port.
■ If the reflector port’s bandwidth is insufficient to handle the traffic from the correspond-
ing source ports, the excess packets are dropped. A 10/100 port reflects at 100 Mbps. A
Gigabit port reflects at 1 Gbps.
1439_CCNP_3.book Page 557 Monday, November 15, 2004 10:35 AM

RSPAN 557

The global configuration command necessary to assign an existing port as a reflector port is
as follows:
monitor session session-number destination remote vlan vlan-id reflector-port
interface

■ session-number is the RSPAN monitoring session.


■ vlan-id identifies the unique RSPAN VLAN.
■ interface specifies the interface that will flood the RSPAN traffic to the RSPAN VLAN.

RSPAN Interaction with Other Features


In addition to SPAN interaction characteristics, RSPAN interacts in the following way with
other switch features:
■ Spanning Tree Protocol (STP)—A reflector port does not participate in STP while its
RSPAN session is active. STP can be active on trunk ports carrying an RSPAN VLAN.
■ VLAN Trunking Protocol (VTP)—VTP can be used to prune an RSPAN VLAN
between switches.
■ VLANs and trunking—VLAN membership or trunk settings can be modified for
reflector ports at any time. However, changes in VLAN membership or trunk settings
for a destination or reflector port do not take effect until the RSPAN session is disabled.
■ EtherChannel groups—If a physical port belonging to an EtherChannel group is a
reflector port and the EtherChannel group is a source, the port is removed from the
EtherChannel group and from the list of monitored ports.

RSPAN and RSPAN VLANs


The following restrictions apply when you configure SPAN and RSPAN sessions on a 2950
series switch:
■ There is a limit of one active source session for either SPAN or RSPAN.
■ A 2950 switch cannot support both SPAN and RSPAN source processes simultaneously.
■ RSPAN source sessions have one destination per session with an RSPAN VLAN asso-
ciated for that session.
■ Each RSPAN destination session has one or more destination interfaces for each
RSPAN VLAN it supports.
■ RSPAN destination sessions are limited to two, or one if a local SPAN or source
RSPAN session is configured on the same switch.
On a 3550 series switch, a maximum of two SPAN or RSPAN sessions can be configured and
stored in NVRAM on each switch. The two sessions can be divided between SPAN, RSPAN
source, and RSPAN destination sessions. Multiple source ports or source VLANs can be con-
figured for each session.
1439_CCNP_3.book Page 558 Monday, November 15, 2004 10:35 AM

558 Chapter 9: Monitoring and Security

The Catalyst 6500 series switch, configured as an RSPAN source switch, can support up to 30
RSPAN destination sessions.
In a network consisting of only Catalyst 2950 series switches, each RSPAN source switch
should be configured with a unique RSPAN VLAN. If two or more switches use the same
RSPAN VLAN, they can act only as RSPAN source switches to ensure the delivery of all
monitored traffic to the RSPAN destination switch.
Any VLAN on either the Catalyst 2950 series or 3550 series switch can be configured as an
RSPAN VLAN as long as the following conditions are met:
■ The RSPAN VLAN cannot be configured as a native VLAN on a Catalyst 2950 series
switch.
■ Extended range RSPAN VLANs configured on a Catalyst 2950 series switch are not
propagated to other switches using VTP.
■ No access port is configured in the RSPAN VLAN.
■ All participating switches support RSPAN.
■ The same RSPAN VLAN is used for an RSPAN session in all Catalyst 3550 series
switches.
An RSPAN VLAN (a VLAN reserved for use by an RSPAN) should be created and propa-
gated through the switch network before an RSPAN source or destination session is config-
ured. If VTP is enabled in the network, the RSPAN VLAN can be created on a single VTP
server switch, and it is propagated to other VTP switches in the VTP domain. If VTP pruning
is also enabled, RSPAN traffic is pruned by the VLAN trunks to prevent any unwanted flood-
ing of RSPAN traffic across the network for VLAN-IDs lower than 1005. Also, MAC address
learning is disabled on the RSPAN VLAN.

Configuring RSPAN
Configuring an RSPAN session is similar to the procedure you follow when configuring
SPAN and VSPAN, as shown in Table 9-5.
An initial configuration step is to create an RSPAN VLAN. A unique RSPAN VLAN must be
created for each monitoring session.
Source ports and session IDs are configured as they are in a SPAN session. On the source
switch, an RSPAN VLAN and reflector port are nominated with the following global configu-
ration command:
monitor session-number destination remote vlan vlan-number reflector-port port-id
1439_CCNP_3.book Page 559 Monday, November 15, 2004 10:35 AM

RSPAN 559

Table 9-5 Configuring RSPAN Involves Defining an RSPAN VLAN

Step Command Description

1 configure terminal Enters global configuration mode.

2 vlan vlan-id name vlan-name exit Sets a unique RSPAN VLAN on the
server switch with VTP enabled.

3 no monitor session {session-number | Clears any existing SPAN configuration


all | local | remote} for the session. Specify all to remove
all SPAN sessions, local to remove all
local sessions, or remote to remove all
remote SPAN sessions.

4 monitor session session-number Specifies the RSPAN session and the


source interface interface-id [, | -] source port (monitored port).
[both | rx | tx] For interface-id, specify the source port
to monitor. Valid interfaces include
physical interfaces and port-channel
logical interfaces (port-channel port
channel-number).
(Optional) Specify the direction of traf-
fic to monitor. The default is both sent
and received traffic.

5 monitor session session-number Specifies the RSPAN session, the desti-


destination remote vlan vlan-id nation remote VLAN, and the reflector
reflector-port interface port.
For vlan-id, specify the RSPAN VLAN
to carry the monitored traffic to the des-
tination port.
For interface, specify the interface that
will flood the RSPAN traffic onto the
RSPAN VLAN.

6 end Returns to privileged EXEC mode.

7 show monitor [session session- Verifies entries.


number]

8 copy running-config startup-config (Optional) Saves entries in the configu-


ration file.
1439_CCNP_3.book Page 560 Monday, November 15, 2004 10:35 AM

560 Chapter 9: Monitoring and Security

On the destination switch, the RSPAN VLAN must be nominated as the source of monitored
traffic with the following global configuration command, as shown in Table 9-6:
monitor session session-number source remote vlan vlan-id

Table 9-6 The RSPAN VLAN Is the Source VLAN Specified on the Destination Switch

Step Command Description

1 configure terminal Enters global configuration mode.

2 monitor session session-number Specifies the RSPAN session and the


source remote vlan vlan-id source RSPAN VLAN.
For vlan-id, specify the source RSPAN
VLAN to monitor.

3 monitor session session-number Specifies the RSPAN session and desti-


destination interface interface-id nation interface.
[encapsulation {dot1q}] For interface-id, specify the destination
interface.
(Optional) Specify the encapsulation
header for outgoing packets. The
default is native form.

4 end Returns to privileged EXEC mode.

5 show monitor [session session- Verifies entries.


number]

6 copy running-config startup-config (Optional) Saves entries in the configu-


ration file.

A destination interface is then selected in the same way as it is for SPAN sessions.
Ports can be removed from the monitoring session in the same way as for SPAN sessions, as
shown in Table 9-7.
To display the status of the current RSPAN configuration, use the show monitor session
command, as shown in Example 9-6.
1439_CCNP_3.book Page 561 Monday, November 15, 2004 10:35 AM

RSPAN 561

Table 9-7 Removing RSPAN Ports Is Similar with RSPAN and Basic SPAN

Step Command Description

1 configure terminal Enters global configuration mode.

2 no monitor session session-number Specifies the characteristics of the


source interface interface-id [, | -] RSPAN source port (monitored port) to
[both | rx | tx] remove.
For interface-id, specify the source port
to no longer monitor. Valid interfaces
include physical interfaces and port-
channel logical interfaces (port-
channel port-channel-number).
(Optional) Specify the direction of
traffic (both, rx, or tx) to no longer
monitor. The default is to disable both
receive (rx) and transmit (tx).

3 end Returns to privileged EXEC mode.

4 show monitor [session session- Verifies entries.


number]

5 copy running-config startup-config (Optional) Saves entries in the configu-


ration file.

Example 9-6 The show monitor Command Displays a Remote Source Session

Switch#show monitor session 1

Session 1
---------
Type: Remote Source Session
Source Ports:
RX Only: Fa0/3
TX Only: None
Both: None

continues
1439_CCNP_3.book Page 562 Monday, November 15, 2004 10:35 AM

562 Chapter 9: Monitoring and Security

Example 9-6 The show monitor Command Displays a Remote Source Session (Continued)

Source VLANS:
RX Only: None
TX Only: None
Both: None
Source RSPAN VLAN: None
Destination Ports: None
Encapsulation: Native
Reflector Port: Fa0/4

Configuring RSPAN to Filter Trunks for Specific VLAN Traffic


Trunk VLAN filtering allows analysis of network traffic on a selected set of VLANs on trunk
source ports. Trunk VLAN filtering can be combined with other source ports that belong to
any of the selected VLANs. Based on the traffic type (ingress, egress, or both), SPAN sends
a copy of the network traffic from the selected VLANs to the destination port.
Use trunk VLAN filtering only with trunk source ports. If trunk VLAN filtering is combined
with other source ports that belong to VLANs not included in the selected list of filter
VLANs, SPAN includes only ports that belong to one or more of the selected VLANs in
the operational sources. Table 9-8 outlines the steps to configure VLAN filtering.

Table 9-8 VLANs Can Be Filtered from the List of Mirrored VLANs on Source Trunk
Ports

Step Command Description

1 configure terminal Enters global configuration mode.

2 no monitor session session-number Clears any existing SPAN configuration


for the session.

3 monitor session session-number Specifies the characteristics of the


interface interface-id rx source port (monitored port) and SPAN
session.
For interface-id, specify the source port
to monitor. The interface specified must
already be configured as a trunk port.

4 monitor session session-number filter Limits the SPAN source traffic to spe-
vlan vlan-id [, | -] cific VLANs. For vlan-id, the range is 1
to 4094; do not enter leading 0s.
1439_CCNP_3.book Page 563 Monday, November 15, 2004 10:35 AM

RSPAN 563

Table 9-8 VLANs Can Be Filtered from the List of Mirrored VLANs on Source Trunk
Ports (Continued)

Step Command Description

5 monitor session session-number Specifies the characteristics of the des-


destination interface interface-id tination port (monitoring port) and
SPAN session. For interface-id, specify
the destination port. Physical interfaces
are valid.

6 end Returns to privileged EXEC mode.

7 show monitor [session session- Verifies entries.


number]

8 copy running-config startup-config (Optional) Saves entries in the configu-


ration file.

When a VLAN is cleared, it is removed from the VLAN filter list. A SPAN session is disabled
if the VLAN filter list becomes empty.
Trunk VLAN filtering is not applicable to VSPAN sessions.
To monitor all VLANs on the trunk port, use the following global configuration command:
no monitor session session_number filter

Example 9-7 shows how to clear any existing configuration on SPAN session 2, configure SPAN
session 2 to monitor traffic received on trunk port 4, and send traffic for only VLANs 1 to 5
and 9 to destination port 8.

Example 9-7 VLAN Trunk Traffic Can Be Filtered in a SPAN Session

Switch(config)#no monitor session 2


Switch(config)#monitor session 2 source interface gigabitethernet 0/4 rx
Switch(config)#monitor session 2 filter vlan 1 - 5 , 9
Switch(config)#monitor session 2 destination interface gigabitethernet0/8
Switch(config)#end

Lab 9.9.3 Creating an RSPAN Session


In this lab exercise, you create an RSPAN session on two switches to remotely mon-
itor network traffic.
1439_CCNP_3.book Page 564 Monday, November 15, 2004 10:35 AM

564 Chapter 9: Monitoring and Security

Interactive Media Activity Crossword Puzzle: Common Terminology Used


When Discussing SPAN, VSPAN, and RSPAN
In this Interactive Media Activity, you practice the terminology pertaining to SPAN
technologies.

Interactive Media Activity Checkbox: SPAN, VSPAN, and RSPAN Port Types
In this Interactive Media Activity, you practice the operational rules of SPAN and
RSPAN.

Network Analysis Modules and Switch Fabric Modules


With the increased capability of access, distribution, and core layer switches to monitor net-
work traffic, it is desirable to capture this monitored traffic at switching aggregation points. In
this way the data can be recorded and analyzed at a central location.
Extra data flow generated by monitored traffic puts additional load on a network’s switching
bandwidth. A trend toward integration of time-sensitive voice over IP (VoIP) and interactive
multimedia services into data networks further exacerbates the situation. These developments
make it imperative that the switching fabric at aggregation points have sufficient bandwidth
to ensure that latency does not become an issue with mission-critical, time-sensitive traffic.
The preceding issues have been addressed by the introduction of two modules for the Cata-
lyst 6500 series chassis:
■ The Network Analysis Module (NAM) contains features that let it store and analyze
multiple monitored traffic streams in real time. This enhances the network engineer’s
ability to capture valuable information and to fast-track problem solving. Figure 9-5
shows the recommended NAM placement in a campus network.
■ The Switch Fabric Module (SFM), illustrated in Figure 9-6, is designed to address the
requirement for increased switching bandwidth, catering to traffic monitoring and the
increasing integration of high-priority time-sensitive traffic into the data network.
The following sections explore the NAM and SFM features and installation and configuration
issues in greater depth.
1439_CCNP_3.book Page 565 Monday, November 15, 2004 10:35 AM

Network Analysis Modules and Switch Fabric Modules 565

Figure 9-5 NAMs Enable Prescriptive Traffic Monitoring as Appropriate for Distinct Parts of
the Network

NAM Branch Office


WAN Remote Troubleshooting
and Performance
Monitoring

NAM NAM WAN Edge


Application Utilization
for Local and Remote
NetFlow Data Export
WAN Links
to Remote NAM

NAM
NAM

NAM

NAM

NAM

Access Distribution Core Data Center


Troubleshooting Traffic Utilization Application
Critical Clients Monitoring and Performance Monitoring
Troubleshooting

Figure 9-6 The Switch Fabric Module Enables Increased Bandwidth to Fabric-Enabled Line Cards

Layer 2 Supervisor Engine

Fabric-Enabled Module
Standard SFM
32 Gb 256 Gb
Backplane Backplane
Non-Fabric Enabled Module

Switch Fabric Module


1439_CCNP_3.book Page 566 Monday, November 15, 2004 10:35 AM

566 Chapter 9: Monitoring and Security

The Network Analysis Module


Network managers rely on a variety of tools for efficient network management and monitor-
ing. Historically, LAN switches have improved network performance but have prevented net-
work administrators from monitoring switched traffic. This is because remote monitoring
(RMON) works best on shared networks, where it can see all traffic.
LAN switches demand greater monitoring control because they filter traffic so that it does not
show on a port unless it is either destined for, or has originated from, a device connected to
that port. The need for “increased visibility” into network activity for different network seg-
ments has made it difficult for administrators to tune network performance and has impeded
troubleshooting in switched networks.
The NAM is a LAN monitoring solution that should be deployed at LAN aggregation points
where it can see critical traffic and virtual LANs (VLANs), as illustrated in Figure 9-7.

Figure 9-7 NAMs Are Deployed at LAN Aggregation Points

Backbone/Core

Catalyst 6500 Catalyst 6500


NAM NAM Distribution
Catalyst 6500 Catalyst 6500 Catalyst 6500
NAM
NAM NAM Access

Catalyst Catalyst
4000 Catalyst 6500
4000 NAM
Server Cluster

Critical
Clients

CallManager Cluster
Data Center

VLAN VLAN VLAN VLAN VLAN VLAN


100 100 100 100 100 100
1439_CCNP_3.book Page 567 Monday, November 15, 2004 10:35 AM

Network Analysis Modules and Switch Fabric Modules 567

Remote Monitoring (RMON) is a standard monitoring specification that lets various network
monitors and console systems exchange network-monitoring data. RMON gives network
administrators more freedom to select network-monitoring probes and consoles with features
that meet their particular networking needs.
The Cisco Catalyst 6500 series switches already have built-in RMON features with data col-
lection in the statistics, history, alarm, and event groups. Additional RMON and RMON2
features require the use of network monitoring instrumentation.
The NAM provides remote monitoring functions that are based on RMON and RMON2
Management Information Bases (MIBs). The NAM collects data at all layers so that network
managers can obtain a broad spectrum of analyses. NAM uses range from fault isolation and
troubleshooting to capacity planning and management, performance management, applica-
tion monitoring, and debugging.
The NAM occupies one full slot in any Cisco Catalyst 6500 series chassis.
The NAM can collect statistics from both data and voice streams, simplifying overall man-
agement. The NAM uses SPAN or RSPAN to accept data from physical ports, VLANs, Ether-
Channel, and NetFlow data export frames. The NAM simultaneously monitors multiple switch
ports or VLANs and provides separate RMON/RMON2 statistics for each data source.

Using the NAM


The NAM can be used for network analysis for a variety of functions, including, but not lim-
ited to, TACACS, SNMP, and the capture of SPAN information. The remainder of this section
discusses the use of NAMs in relation to SPAN sessions.
The NAM Traffic Analyzer, shown in Figure 9-8, is a web-based monitoring application
embedded in the NAM software. The application provides comprehensive traffic monitoring
and analysis capabilities on board the NAM in addition to its traffic statistics collection func-
tionality. This functionality combines the roles of the monitoring agent and analysis applica-
tion in the same device.
The NAM Traffic Analyzer runs on a web server on the NAM itself and is accessible through
a web browser (Microsoft Internet Explorer 5.0 and above, Netscape 4.7 and above). The
NAM Traffic Analyzer enables troubleshooting and monitoring of applications, such as IP
Telephony and quality of service (QoS).
The NAM automatically learns VLANs from the switch but does not automatically SPAN
them. The Active SPAN Sources window in the NAM graphical user interface (GUI) must be
used to SPAN them.
1439_CCNP_3.book Page 568 Monday, November 15, 2004 10:35 AM

568 Chapter 9: Monitoring and Security

Figure 9-8 The NAM Traffic Analyzer Is Viewed on a Web Browser

5 2 4 6 1

1. Tabs for accessing main functions; tabs are displayed in every window.
2. Options associated with each tab; functions change in each tab depending on context.
3. Where applicable, contents of functions related to the current context.
4. Content are where graphs, tables, dialog boxes, charts, and instruction boxes are
displayed.
5. Toolbar to access global functions.

Key features of the NAM Traffic Analyzer include the following:


■ Monitoring capabilities—It supports full RMON and RMON2 monitoring to analyze
network traffic up to the application layer for hosts, conversations, applications.
■ Voice and QoS monitoring—It offers Differentiated Services Monitoring (DSMON)
and IP telephony monitoring capabilities, including protocol utilization, call and phone
attributes, and violations of QoS policies.
■ Troubleshooting capabilities—The NAM Traffic Analyzer can capture and decode
data and voice packets in real time to troubleshoot network problems, including alarm
capabilities and drill-down views of traffic to identify potential problems before they
occur.
■ Web access—It provides instant access to traffic statistics.
■ Secure web access—Users can enable the HTTP over Secure Socket Layer (HTTPS)
server on the NAM and use up to 168-bit encryption for data exchange.
■ Role-based user administration—Provides local and remote (TACACS+) authentica-
tion and authorization capabilities to assign different levels of roles and privileges to
users.
1439_CCNP_3.book Page 569 Monday, November 15, 2004 10:35 AM

Network Analysis Modules and Switch Fabric Modules 569

The NAM has no network interfaces. Monitored packets are forwarded to the line module
using SPAN or RSPAN functionality that mirrors any switch port or VLAN on the NAM. The
NAM supports simultaneous monitoring of multiple ports or VLANs and maintains indepen-
dent group statistics for each data source. Any data source, such as physical ports, VLANs,
EtherChannel, or NetFlow data export frames, that can be directed to the NAM using the
SPAN or RSPAN function is supported for RMON data collection.
With the help of SPAN configuration on the Supervisor, the NAM can also monitor Ether-
Channel. On the Supervisor, each physical port in the bundle is mirrored into the NAM.

Interactive Media Activity Checkbox: Network Analysis Module (NAM)


In this Interactive Media Activity, you reinforce your knowledge of the basic facts
pertaining to the NAM.

Benefits of Deploying a NAM


The NAM Traffic Analyzer interface becomes a key element in expediting the network trou-
bleshooting process.
The NAM can be deployed in any Cisco Catalyst 6500 series chassis. It offers the following
benefits:
■ An integrated solution—By occupying a single slot within the Cisco Catalyst 6500
chassis, the NAM helps administrators conserve rack space. NAM gets its data from the
switch’s backplane, and the spanned traffic does not flow out the switch.
■ A complete LAN network monitoring solution—The NAM includes the web
browser-accessible Traffic Analyzer application for monitoring and troubleshooting.
■ Scalable performance—Multiple NAMs can be deployed within a switch chassis.
Network monitoring capacity can be increased as needed.
■ Standards-based—The NAM is completely standards-compliant, including full
RMON-1 (RFC 2819), RMON-2 (RFC 2021), High-capacity Remote Monitoring
(HCRMON), and Switch Monitoring (SMON) (RFC 2613) support for monitoring in
LAN environments. It also implements DSMON and the RFC 2074 protocol directory
standard.

NAM Troubleshooting
The NAM has no network interfaces. Troubleshooting for the NAM occurs using the web-
based interface NAM Traffic Analyzer. Most troubleshooting generally occurs at the SPAN/
VSPAN/RSPAN configuration level. The NAM Traffic Analyzer aids in fast-tracking the
troubleshooting process. Figure 9-9 shows a NAM troubleshooting flowchart.
1439_CCNP_3.book Page 570 Monday, November 15, 2004 10:35 AM

570 Chapter 9: Monitoring and Security

CAUTION Figure 9-9 Troubleshooting the NAM Depends on Whether the Problem Is Hardware-Based
When removing a
NAM module from the
switch chassis, you Problem Yes
must take care to prop- Hardware
erly shut down the Based?
module. The NAM can
be damaged if removed No No
Response From NAM Root Response
from the switch before Account Enter
it completely shuts Shutdown Command
down—a process that Use NAM Traffic
Analyzer to Establish
might require several
the SPAN/VSPAN/
minutes.
RSPAN Session at Fault

Enter SPAN/VSPAN/ Switch (config) #


RSPAN Configuration hw-mod module mod
Corrections on Affected shutdown
Switches

NAM Safe to Remove Manual Shutdown

From the root account on the NAM, enter the shutdown command.
In privileged mode from the CLI, enter the hw-mod module mod shutdown command.
(When this command is used, the hw-mod module mod reset command must be entered to
restart the NAM.)
If the NAM does not respond to any commands from the NAM prompt or the Supervisor
Engine, use a small, pointed object to access the SHUTDOWN button, similar to how you
press the inset button on a Cisco Aironet 350 series wireless bridge.

Increasing Switching Fabric in Catalyst 6500 Series Switches


The Catalyst 6500 series Switch Fabric Module (SFM), in combination with the Supervisor
Engine 2, delivers an increase in available system bandwidth from the default 32 Gbps on the
forwarding bus to 256 Gbps. Including an SFM in a Catalyst 6500 chassis increases the speed
at which switching, routing, and network monitoring modules can transfer data between each
other. The SFM reduces latency and the incidence of packet drop caused by bandwidth bottle-
necks at traffic aggregation points within the network.
The SFM creates a dedicated connection between fabric-enabled modules and provides unin-
terrupted transmission of frames between these modules. The SFM also provides fabric-
enabled modules with a direct connection to the Catalyst 6500 32-Gbps forwarding bus. If
1439_CCNP_3.book Page 571 Monday, November 15, 2004 10:35 AM

Network Analysis Modules and Switch Fabric Modules 571

two SFMs are installed in the chassis, the secondary module acts as a backup in the event of
failure of the first module.
The SFM, shown in Figure 9-10, does not have a console. A two-line LCD display on the
front panel shows fabric utilization, software revision, and basic system information.

Figure 9-10 The SFM Can Effect a Seven-Fold Increase in Forwarded Packets Per Second and an
Eight-Fold Increase in Available System Bandwidth on a Catalyst 6500

The following are the key features of the SFM:


■ It enables 30 Mpps Cisco Express Forwarding (CEF)-based central forwarding on
Supervisor Engine 2.
■ It enables up to 210 Mpps distributed forwarding on supported line cards.
■ It supports advanced services, such as QoS and security in hardware, through access
control lists (ACLs).
Fabric-enabled modules in a Catalyst 6500 are modules whose capacity is enhanced by the
introduction of the SFM. When an SFM is installed, the traffic is forwarded to and from mod-
ules in one of the following modes:
■ Bus mode—Data passes between the local bus and the Supervisor Engine bus. This
mode is used for traffic to or from non-fabric-enabled modules and between fabric-
enabled and non-fabric-enabled modules.
■ Truncated mode—Only the truncated data (the first 64 bytes of the frame) is sent over
the switch fabric channel if both the destination and the source are fabric-enabled mod-
ules. If either the source or destination is not a fabric-enabled module, the data goes
through the switch fabric channel and the data bus. The SFM does not get involved
when traffic is forwarded between non-fabric-enabled modules.
■ Compact mode—A compact version of the DBus header is forwarded over the switch
fabric channel, delivering the best possible switching rate. Non-fabric-enabled modules
do not support the compact mode and generate cyclic redundancy check (CRC) errors
if they receive frames in compact mode. This mode is used only when no non-fabric-
enabled modules are installed in the chassis.
1439_CCNP_3.book Page 572 Monday, November 15, 2004 10:35 AM

572 Chapter 9: Monitoring and Security

Interactive Media Activity Drag and Drop: The Mode Type Used to Forward
Traffic Internally on a Catalyst 6500 with SFM
After completing this Interactive Media Activity, you will understand the mode type
on a Catalyst 6500 with an SFM.

Configuring the Switch Fabric Module


The SFM does not require any user configuration. A fully automated startup sequence brings
the module online and runs the connectivity diagnostics on the ports. Based on the other
modules in the chassis, the SFM determines which mode to operate in.
To manually configure the switching mode (supported in Cisco IOS Release 12.1(11b)E and
later), use the following global configuration command:
fabric switching-mode allow {bus-mode | {truncated [{threshold [number]}]}

To configure fabric-required mode, which prevents all switching modules from operating
unless an SFM is installed, use the global configuration command fabric required.
This effectively turns off all modules except the Supervisor Engine if no SFM is installed.
Use the no fabric required command to clear fabric required mode.

Monitoring the Switch Fabric Module


The SFM supports a number of show commands for monitoring purposes, as shown in
Table 9-9. A fully automated startup sequence brings the module online and runs the connec-
tivity diagnostics on the ports.

Table 9-9 A Number of show Commands Are Available to Monitor the SFM

Command Description

show module {5 | 6 | 7 | 8} Displays module information.


show fabric active Displays SFM redundancy status.

show fabric switching-mode [module Displays the fabric channel switching mode
{slot-number} | all] for one or all of the modules.

show fabric status [slot-number | all] Displays the fabric status for one or all of the
modules.

show fabric utilization [slot-number | all] Displays the fabric utilization for one or all
of the modules.

show fabric errors [slot-number | all] Displays fabric errors for one or all of the
modules.
1439_CCNP_3.book Page 573 Monday, November 15, 2004 10:35 AM

Network Analysis Modules and Switch Fabric Modules 573

The SFM show commands monitor the SFM in the following ways:
■ Display module information (see Example 9-8)
■ Display the active fabric cards (see Example 9-9)
■ Display fabric channel switching modes (see Example 9-10)
■ Display fabric status (see Example 9-11)
■ Display the fabric utilization (see Example 9-12)
■ Display any fabric errors (see Example 9-13)

Example 9-8 show module Displays Module Information

Router#show module 5

Mods Ports Card Type Model Serial No.


---- ----- -------------------- ------------- -----------
5 0 Switching Fabric Module WS-c6500-SFM SAD04420JR5

Mod MAC addresses Hw Fw Sw Status


--- -------------------------------- -- ----- -------- ------
5 0001.0002.0003 to 0001.0002.0003 1.0 6.1(3) 6.2(0.97) Ok

Example 9-9 show fabric active Displays the Active Fabric Cards

Router#show fabric active


Active fabric card in slot 5
No backup fabric card in the system

Example 9-10 show fabric switching-mode all Displays Fabric Channel Switching Modes

Router#show fabric switching-mode all


bus-only mode is allowed
Module Slot Switching Mode
1 Bus
2 Bus
3 DCEF
4 DCEF
5 No Interfaces
6 DCEF
1439_CCNP_3.book Page 574 Monday, November 15, 2004 10:35 AM

574 Chapter 9: Monitoring and Security

Example 9-11 show fabric status all Displays Fabric Status

Router#show fabric status all

slot channel module fabric


status status
1 0 OK OK
3 0 OK OK
3 1 OK OK
4 0 OK OK

Example 9-12 show fabric utilization all Displays Fabric Utilization

Router#show fabric utilization all


slot channel Ingress% Egress%
1 0 0 0
3 0 0 0
3 1 0 0
4 0 0 0
4 1 0 0
6 0 0 0
6 1 0 0
7 0 0 0
7 1 0 0

Example 9-13 show fabric errors Displays Any Fabric Errors

Router#show fabric errors


slot channel module module module fabric
crc hbeat sync sync
1 0 0 0 0 0
3 0 0 0 0 0
3 1 0 0 0 0
4 0 0 0 0 0
4 1 0 0 0 0
6 0 0 0 0 0
6 1 0 0 0 0
7 0 0 0 0 0
7 1 0 0 0 0
1439_CCNP_3.book Page 575 Monday, November 15, 2004 10:35 AM

Basic Security 575

Basic Security
A number of rudimentary security measures are available on Catalyst switches to prevent
unauthorized access. Both out-of-band and in-band management connections to Catalyst
switches are possible. Basic password protection is simple to configure. Restricting physical
access to switches must also be taken into account.

Access Control Policy


Implementation of any access control begins with the creation of a standard access policy. An
access policy defines access rights and privileges for the network users. The access policy
should provide guidelines for connecting external networks, connecting devices to a network,
and adding new software to systems.
Most access policies outline the following information:
■ Network device management issues, such as physical security and access control
■ User access to the network
■ Traffic-flow policies
■ Route filtering
Each layer of a hierarchical network will probably have a different access policy, because
each layer is responsible for different tasks. Figure 9-11 illustrates a campus network where
an access policy should be defined.

Figure 9-11 A Network Policy Can Be Implemented at the Access Layer

Switch Block
Building A Building B Building C

Access Layer

Distribution Layer

Core Block

Token
Ring
WAN Block

Mainframe Block

Server Block
1439_CCNP_3.book Page 576 Monday, November 15, 2004 10:35 AM

576 Chapter 9: Monitoring and Security

The access layer, highlighted in Figure 9-11, is the point at which local end users are allowed
into the network. Port security can be used to control traffic at the access layer. Passwords can
be used to protect network devices. The access layer can also use VLANs, access lists, or fil-
ters to further optimize traffic control for a particular set of users.
The network’s distribution layer is the demarcation point between the access and core layers,
as shown in Figure 9-12. This layer helps define and differentiate the core. Providing bound-
ary definition, the distribution layer is where packet manipulation should take place. The dis-
tribution layer should be responsible for ensuring that only necessary traffic makes it to the
core or another switch block. The distribution layer can be summarized as the layer that pro-
vides policy-based connectivity.

Figure 9-12 A Network Policy Can Be Implemented at the Distribution Layer

Switch Block
Building A Building B Building C

Access Layer

Distribution Layer

Core Block

Token
Ring
WAN Block

Mainframe Block

Server Block

The core layer is a high-speed switching backbone, as shown in Figure 9-13, and it should be
designed to switch packets as fast as possible. This layer of the network should not perform
any packet manipulation, such as access lists and filtering, which would slow down the
switching of packets.
1439_CCNP_3.book Page 577 Monday, November 15, 2004 10:35 AM

Basic Security 577

Figure 9-13 A Network Policy Is Rarely Implemented at the Core Layer

Switch Block
Building A Building B Building C

Access Layer

Distribution Layer

Core Block

Token
Ring
WAN Block

Mainframe Block

Server Block

Basic Security Measures


Controlling access to network devices, such as switches and routers, should be one of the first
priorities of an access policy. Every device at every layer of the hierarchical model should
have a plan for physical security, password protection, privilege levels, and remote control
(Telnet/SSH/HTTP) access. The following sections address these issues.

Physical Security
Physical access to a router or switch gives a sufficiently sophisticated user total control over
that device. Nearly all switches and routers have “password-recovery techniques” or other
backdoors to access the device without a password. These techniques are publicly docu-
mented on the Internet. Installing software security measures makes no sense when access to
the hardware is not controlled.
Physically secure network devices by doing the following:
■ Provide the proper physical environment—This includes lockable doors and backup
power supplies, as shown in Figure 9-14.
■ Control direct access to the device—This includes lockable racks (see Figure 9-15)
and password protection to console and auxiliary ports. Ports that are not being used
should also be disabled.
1439_CCNP_3.book Page 578 Monday, November 15, 2004 10:35 AM

578 Chapter 9: Monitoring and Security

Figure 9-14 Lockable Doors Let You Secure Network Equipment

Figure 9-15 Lockable Racks Control Direct Access to Network Devices


1439_CCNP_3.book Page 579 Monday, November 15, 2004 10:35 AM

Basic Security 579

Connecting to the Switch


Cisco devices may be accessed using in-band management or out-of-band management.
■ Out-of-band management—Using a separate communications channel for manage-
ment traffic and data traffic. These channels can be physically or logically separate.
■ In-band management—Using a common communications channel for both data and
management traffic.

Out-of-Band Management
Out-of-band management options include the following:
■ Console 0 (con0)
■ Auxiliary 0 (aux0)
Figures 9-16, 9-17, and 9-18 illustrate the location of the console port on various Cisco
switching devices.

Figure 9-16 The Console Port Is on the Supervisor Engine on a Catalyst 6500

Console Port
1439_CCNP_3.book Page 580 Monday, November 15, 2004 10:35 AM

580 Chapter 9: Monitoring and Security

Figure 9-17 The Console Port Is on the Back of a Catalyst 3550

Console Port

Console Port

Figure 9-18 The Console Port Is on the Back of a Catalyst 2950

Console Port

Console Port

NOTE Console and auxiliary ports can be directly attached to local management terminals using
Connecting modems to serial connections for local out-of-band management. Modems can also be connected to con-
the switch console port
sole and auxiliary ports to support out-of-band management from remote locations, as illus-
can allow network
administrators to access trated in Figure 9-19.
remote devices during
data network outages. Figure 9-19 A Modem Can Be Connected to a Console Port for Remote Administration
Because connecting
modems to remote Switch with Modem Connected Console Port
devices allows access to
the device console or
auxiliary port from any-
one using the public
telephone network, the
phone number used to
dial into the device
should be kept secret.

Remote Out-of-Band Management Station


1439_CCNP_3.book Page 581 Monday, November 15, 2004 10:35 AM

Basic Security 581

Remote devices with modems connected to console or auxiliary ports should also be config-
ured with complex passwords. That is, passwords should not use real words and should be
made up using a combination of numbers (0 to 9), upper- and lowercase letters (a to z, A
to Z), and special characters (! @ # $ % ^ & * { } [ ]).

In-Band Management
In-band management options include the following:
■ Virtual terminal (vty) ports used for remote terminal access, as shown in Figure 9-20.
■ Web interface (HTTP) used for remote monitoring and control
■ TFTP
■ Network management protocols, such as Simple Network Management Protocol
(SNMP) and network management software, such as CiscoWorks

Figure 9-20 Virtual Terminal Access Is Provided Via Telnet

Unencrypted vty console sessions can be established using Telnet. Encrypted vty terminal
console sessions can be established using a Secure Shell (SSH) client. Using encrypted com-
munications for vty console sessions wherever possible provides better security for network
devices.
Cisco IOS devices can be configured to allow remote monitoring and control functions
through a normal web browser using HTTP. The web interface is inherently insecure and
should be disabled if possible, especially in large networks with sophisticated users.
A TFTP server can be used to load a common configuration script onto Cisco IOS devices.
This can be used as an efficient mechanism to manage a large number of network devices.
1439_CCNP_3.book Page 582 Monday, November 15, 2004 10:35 AM

582 Chapter 9: Monitoring and Security

Access to the TFTP server implicitly provides console access to a large number of IOS
devices in the network at the same time. Because of this, the TFTP server must be secured
and managed appropriately to prevent accidental or malicious misconfiguration of any shared
configuration scripts.
Cisco IOS devices support monitoring and management functions provided by SNMP.
Because SNMP was not originally designed with built-in security, using SNMP should be
restricted to monitoring functions wherever possible.
You can gain additional control over these in-band management options using a management
VLAN and access lists. Use of the advanced in-band management features is covered in the
section “Securing User Access.”

Interactive Media Activity Checkbox: Direct Access to Cisco Devices


After completing this Interactive Media Activity, you will better understand in-band
and out-of-band access to Cisco devices.

Basic Password Protection


The factory-default configuration for Cisco IOS devices does not contain any passwords.
Cisco IOS-based devices support three types of local passwords for use with both out-of-
band and in-band connections:
■ Enable and secret passwords
■ Line passwords
■ Local usernames and passwords
By default, all passwords in a Cisco IOS device are stored in clear text, as shown in Figure 9-21,
with the exception of the optional enable secret password.
The enable password is unencrypted, as shown in Example 9-14.
Passwords can be encrypted using the global configuration service password-encryption
command, as shown in Example 9-15. Notice that the enable password line in the configura-
tion script now has the number 7 before the encrypted password. This tells the IOS that the
string of numbers and letters is an encrypted password.
1439_CCNP_3.book Page 583 Monday, November 15, 2004 10:35 AM

Basic Security 583

Figure 9-21 Passwords Are Not Encrypted by Default

Router (config)#enable secret C0nfigMe


Router (config)#line con 0
Router (config-line)#password Log!n2Me
Router (config-line)#login
Router (config-line)#line vty 0 4
Router (config-line)#password RemoTe2me
Router (config-line)# login

ALSwitch (config)#enable secret SetMeUp1


ALSwitch (config)#line con 0
ALSwitch (config-line)#password Acc3ss
ALSwitch (config-line)#login
ALSwitch (config-line)#line vty 0 15
ALSwitch (config-line)#password RemConSole
ALSwitch (config-line)#login

Core (config)#enable secret Conf!g9

Example 9-14 The Enable Password Is Unencrypted

Access1#show running-config
Building configuration...

Current configuration : 947 bytes


1
version 12.1
no service pad
service timestamps debug uptime
service timestamps log uptime
no service password-encryption
!
hostname Access1
!
enable password SetMeUp1
!
1439_CCNP_3.book Page 584 Monday, November 15, 2004 10:35 AM

584 Chapter 9: Monitoring and Security

Example 9-15 Passwords Can Be Encrypted with the service password-encryption Command

Access1#show running-config
Building configuration...

Current configuration : 956 bytes


1
version 12.1
no service pad
service timestamps debug uptime
service timestamps log uptime
service password-encryption
!
hostname Access1
!
enable password 7 06350A35614B3C0954
!

Every method of accessing the device should have a password applied to prevent unautho-
rized access. By default, console and auxiliary ports have no password protection. The enable
password is the password used to restrict access to privileged EXEC mode.
Passwords defined for individual console, auxiliary, or vty lines are called line passwords.
Cisco IOS devices can also store locally defined usernames as passwords. Using local user-
names and passwords allows the network administrator to create individual logins for users
and define additional options and controls on a per-user basis. Using the advanced options
with local usernames is covered in the section “Advanced Username Options.”
It is better to have users log in to the system using an individual username and password,
rather than having everyone use the line password. Having users log in to the device using
their own usernames makes it easier to track down who is accessing the device and what
changes they have made.

Lab 9.9.4 Setting Encrypted Passwords


In this lab exercise, you configure passwords on switch console ports and virtual
terminal lines.
1439_CCNP_3.book Page 585 Monday, November 15, 2004 10:35 AM

Securing Remote Management 585

Securing Remote Management


Several options are available for remote management of Catalyst switches. These include Tel-
net, SSH, web browsing, and SNMP. SSH is commonly used nowadays as a secure means of
administering devices remotely. Using Telnet is generally not an option anymore because of its
use of plain text. Web management is also a security risk but is commonly used in a localized
fashion. Many Cisco GUIs, such as the Security Device Manager, rely on web access and pro-
vide a user-friendly means of configuring complicated technologies. Access lists and judicious
VLAN usage add another level of security to the remote management solution.

Remote Management Security Options


Out-of-band connections from remote locations need to have a modem connected to the console
or auxiliary port of the device being managed. You can control who has access to the modem
by combining advanced local username options with callback technology to ensure that specific
users can establish dial-in modem sessions from only specific locations. Configuring modem
callback security is covered in the CCNP 2 Remote Access course.
In-band management traffic shares bandwidth with user traffic and can be segregated from
user traffic using the following features:
■ Local usernames
■ SSH session encryption
■ VLANs
■ Access lists
In-band management connections can also be controlled using advanced local username
options. The next section covers advanced local username options for controlling both out-
of-band and in-band connections.

Lab 9.9.5 Using Local Usernames and Passwords


In this lab exercise, you configure multiple local usernames with passwords. These
are used for login authentication on the console port and virtual terminal lines.

Advanced Username Options


A variety of user-specific options are available for configuration in the Cisco IOS. These NOTE
commands can be used either singularly or in combination to provide granular control These commands are
stored in the running
over connections to the device. These options can be entered individually or together in a
configuration as a
single command. single command.
1439_CCNP_3.book Page 586 Monday, November 15, 2004 10:35 AM

586 Chapter 9: Monitoring and Security

Storing a User Password Using Strong Encryption


NOTE The first of these commands is username name secret password. This command is used to
The username name store a user’s password using strong encryption, even if service password-encryption is not
secret password com-
enabled. For example:
mand is used as an
alternative to the user- username cde secret xyz
name name password
password command. The result in the running config appears as follows:
username cde secret 5 $1$HgUN$q15OB5AxLvpT7w/zp2vn

Creating a Generic User Account


Using the username name nopassword command creates a user account that does not
require a password to log on. This feature might be used for a generic account and should be
implemented only in conjunction with a limited privilege level associated with that username.
For example:
ALSwitch(config)#username Helpdesk nopassword

The result in the running config appears as follows:


username Helpdesk nopassword

Use of this feature in a production environment is not recommended.

Limiting the Scope of Commands Available to a User Account


The username name privilege level command is used to limit the scope of commands avail-
able to a particular user. Consider the following example:
ALSwitch(config)#username Helpdesk privilege 1
ALSwitch(config)#username Bob privilege 15

The command username Helpdesk privilege 1 gives Alice user-mode access after she
authenticates with the server. The command username Bob privilege 15 gives Bob
privileged-mode access after he authenticates with the server.
The result in the running config appears as follows:
username Helpdesk privilege 1 no password
Username Bob privilege 15 secret 5
$1$f3mK$C5PuyHwjT0T0fvNgPDwT60

Limiting the Maximum Number of Simultaneous Sessions Available


to a User Account
The username name user-maxlinks number command is used to limit the maximum number
of sessions a particular username can establish simultaneously. This can be used to control
the use of resources by users, giving different user accounts different levels of access to
resources.
1439_CCNP_3.book Page 587 Monday, November 15, 2004 10:35 AM

Securing Remote Management 587

For example:
ALSwitch(config)#username Helpdesk user-maxlinks 2

The result in the running config appears as follows:


username Helpdesk privilege 1 nopassword user-maxlinks 2

Binding Access Lists to a User Account


Access lists can be bound to specific usernames using the username name access-class
access-list command. This forces session traffic from a specific user to match permit state-
ments defined in an access list to establish a successful connection.
For example, with these commands, an administrator has a large degree of flexibility. A guest
login account can be created that requires no password, has user-mode access only, is limited
to a maximum of two simultaneous sessions, and can be used only from a defined IP host or
subnet on the network. For example:
ALSwitch(config)#username Carol access-class 99

The result in the running config appears as follows:


username Carol access-class 99 secret 5
$1$808J$XeiJBlrFTCLUaZhBcE/y..

Lab 9.9.6 Using Advanced Username Options


In this lab exercise, you configure multiple user accounts with advanced options to
limit privilege levels and use strong encryption to secure passwords.

Interactive Media Activity Checkbox: Username Options for Accessing Cisco


Devices
After completing this Interactive Media Activity, you will better understand user-
name options for accessing Cisco devices.

Encrypting Communications Using Secure Shell


Recall that Ethernet is a broadcast-based technology. This means that all nodes sharing an
Ethernet segment, or nodes attached to a SPAN port in a switched environment, receive a
copy of all frames on the network at Layer 2. This means that the Ethernet network is inher-
ently insecure. Also recall that computers can be configured to use promiscuous mode net-
work drivers, which allow the computers to ignore the Layer 3 information in the packet
header, and record the packets for later examination and analysis.
1439_CCNP_3.book Page 588 Monday, November 15, 2004 10:35 AM

588 Chapter 9: Monitoring and Security

Telnet allows administrators and users to connect to Cisco IOS devices from remote locations
through the production data network. Because Telnet packets are transmitted across the net-
work in clear text (that is, without encryption), these packets can be captured and their con-
tents easily read, including the capture of usernames and passwords.
NOTE SSH allows administrators and users to securely connect to Cisco IOS devices from remote
SSH is available on locations through the production data network. Because the data payload in SSH packets is
Cisco Catalyst 6500
protected by encryption, the contents of any captured SSH packets cannot be easily read, as
IOS-based switches and
Cisco Catalyst 3550 illustrated in Figure 9-22. The recommended practice is that SSH encryption be configured at
IOS-based switches. the minimum for securing in-band management traffic where possible.
SSH is not available on
Cisco Catalyst 2950
Figure 9-22 SSH Encrypts a Session So That Intercepted Traffic Cannot Be Read
switches running Cisco
IOS Release 12.2. Bob

To: Bob

Alice
?
To: Bob
Carol

NOTE Secure Shell (SSH) is an application and a protocol that provides a secure replacement to the
The SSH client func- Berkeley r-tools. This protocol secures the sessions using standard cryptographic mechanisms.
tionality is available
only when the SSH Two versions of SSH currently are available:
server is enabled.
■ SSH Version 1—Implemented in the Cisco IOS software. Consists of an application
and a protocol. The application includes both a server and a client.
■ SSH Version 2—The Catalyst switch supports an SSHv2 server.
The SSH Server feature lets an SSH client make a secure, encrypted connection to a Cisco
IOS device. This connection provides functionality that is similar to that of an inbound Telnet
connection. SSH allows strong encryption to be used in conjunction with Cisco IOS authenti-
cation features. The SSH server in Cisco IOS software works with any commercially avail-
able SSH-compliant client software.
1439_CCNP_3.book Page 589 Monday, November 15, 2004 10:35 AM

Securing Remote Management 589

The SSH Integrated Client feature is an application running over the SSH protocol to provide
device authentication and encryption. The SSH client lets a Cisco IOS device make a secure,
encrypted connection to another Cisco IOS device or to any other device running the SSH
server. This connection provides functionality that is similar to a Telnet connection, except
that this connection is encrypted. With authentication and encryption, the SSH client allows
for secure communications over an insecure network.
The SSH client in Cisco IOS software works with any commercially available SSH-compliant
server software. The SSH integrated client supports the Data Encryption Standard (DES) and
Triple-DES (3DES) ciphers and also supports password-based authentication. User authenti-
cation is performed like that in a Telnet session to a router. The user authentication mechanisms
supported by the SSH integrated client include RADIUS, TACACS+, and locally stored user-
names and passwords.
The following are some basic SSH restrictions:
■ Rivest, Shamir, and Adelman (RSA) authentication, available in SSH clients, is not
supported in the SSH server for Cisco IOS Release 12.2.
■ SSH server and SSH client are available on DES (56-bit) and 3DES (168-bit) data
encryption IOS images only. In DES IOS images, DES is the only encryption algorithm
available to be used by SSH. In 3DES IOS images, both the DES and 3DES encryption
algorithms are available.
The command execution shell is the only application supported on Cisco IOS devices running
the SSH server process.

Interactive Media Activity Crossword Puzzle: Device Access Control Policy:


Definitions
After completing this Interactive Media Activity, you will better understand defini-
tions involving device access control policy.

Encryption Key Pairs


The most common understanding of a data encryption system is based on preshared secret-
key cryptography. Preshared secret-key cryptography is where two parties share the same
secret. This secret is used to both encrypt and decrypt data before sending or reading the
actual data. Anyone who knows the preshared secret key can encrypt and decrypt data.
The problem with a preshared secret-key system is in transferring knowledge of the preshared
secret key to all participating parties while keeping the key secret. This problem was solved
with the development of asymmetric key pair systems, also known as public/private key pairs
or Public Key Infrastructure (PKI).
1439_CCNP_3.book Page 590 Monday, November 15, 2004 10:35 AM

590 Chapter 9: Monitoring and Security

With asymmetric key pairs, the public-key portion is designed to be distributed freely. The
private-key portion must be kept secret. If data is encrypted with the public key, it can be
decrypted only using the corresponding private key. For example, a message encrypted with
the public key cannot be decrypted with the public key. Only the private key can be used to
decrypt the message. This ensures that an eavesdropper cannot decrypt the message without
the secret private key.
Table 9-10 compares the characteristics of asymmetric and symmetric key pairs.

Table 9-10 Asymmetric Key Pairs (Public Key Infrastructure) Are More Secure Than Symmetric
Keys (Preshared Keys)

Symmetric Keys Asymmetric Key Pairs

The same key is used for all encryption Pairs of keys are generated—one key for
and decryption. encryption (public) and another for decryption
(private).

The cryptographic process is mathemati- The cryptographic process is mathematically


cally simpler and faster to process. more complex and slower to process.

The cryptographic process is more easily The cryptographic process is more difficult to
compromised. compromise.

The cryptographic process is two-way: The cryptographic process is one-way: the key
the key used for encryption can also be used for encryption cannot be used for decryp-
used for decryption, which is less secure. tion, and the key used for decryption cannot be
used for encryption, which is more secure.

Keeping the key secret (secure) is Only the decryption key needs to be kept
crucial. secure.

Distributing the key securely can be The encryption (public) key can be distributed
complex. over insecure media.

Also known as the preshared secret key. Also known as the public key infrastructure.

Systems used by digital certificates and Open-


PGP standards.

When an RSA key pair is generated on a Cisco IOS device, both a private key and a public
key are created. After they are generated, these keys can be used to encrypt communications
between the SSH server running on the IOS device and the SSH client. The first time an SSH
client connects to an SSH server, the client is given a copy of the server’s public key. Any data
encrypted using the public key can only be decrypted using the matching private key, which
1439_CCNP_3.book Page 591 Monday, November 15, 2004 10:35 AM

Securing Remote Management 591

is kept secret on the SSH server. Even if many people have copies of the public key, only the
SSH server has the private key, and only the SSH server can decrypt the encrypted communi-
cations. This allows authentication details and session traffic to be exchanged between the
SSH server and client securely.

Using VLANs to Restrict Remote Management


Virtual LANs (VLANs) can be used to control who can establish in-band communications
with the switch. The switch uses VLAN 1 as the management VLAN, unless it is explicitly
configured to be on another VLAN. The management VLAN on a switch is the only VLAN
from which in-band management sessions can be established. When shipped from the factory,
all ports on the switch are configured as members of VLAN1. At factory default settings, the
switch accepts management traffic from any port.
Network administrators should separate management traffic and user traffic. The recom-
mended practice for managing network devices (router and switches) is to establish separate
logical networks for user traffic and management traffic using multiple VLANs and subnets,
as shown in Figure 9-23. The management VLAN should not carry any user traffic. It is also
important that the management VLAN be included in the list of VLANs propagated by the
VLAN Trunking Protocol (VTP) processes. Separating management and user traffic helps
protect the network infrastructure against attacks from network users.

Figure 9-23 VLANs Can Be Used to Separate Management Traffic from User Traffic

Network Management Accounting Engineering


VLAN VLAN VLAN

Note that in a multilayer switched network, a switch does not need to have a port that is a
member of the management VLAN to accept traffic from the management VLAN. Because a
1439_CCNP_3.book Page 592 Monday, November 15, 2004 10:35 AM

592 Chapter 9: Monitoring and Security

trunk port normally passes traffic for all VLANs, the switch accepts management traffic over
a trunked connection.

Lab 9.9.7 Configuring the Management VLAN on a Single Switch


In this lab exercise, you configure and use a nondefault management VLAN. You use
the config-vlan and vlan database modes to configure VLANs.

Securing the Web Management Interface


Cisco switches and routers have the capacity to host a web interface to simplify remote mon-
itoring and management, as shown in Figure 9-24. Because this interface uses insecure proto-
cols, it is not recommended that it be used for remote management. This interface can still be
used to provide access where security is less important, such as for usage monitoring, but it
should still be secured as much as possible. To enable the web interface, use the ip http
server command from global configuration mode.

Figure 9-24 The Catalyst 2950 Web Interface Provides User-Friendly Management

One of the settings for the web interface is the configuration of the TCP port number. The
HTTP server process running on the switch normally listens for connection requests on port
1439_CCNP_3.book Page 593 Monday, November 15, 2004 10:35 AM

Securing Remote Management 593

TCP:80. To configure the HTTP server process to listen on a different port, use the global
configuration command ip http port http-port, where http-port is a number between 1 and
65535.
You also can establish a connection to the switch’s web interface using access control lists.
The global configuration command ip http access-class acl-number is used to bind a stan-
dard access list to the HTTP server process, where acl-number must be between 1 and 99.

Lab 9.9.9 Restricting Web Interface Sessions with Access Lists


In this lab exercise, you define and apply access lists to restrict access to the switch’s
web interface.

Using Access Lists to Restrict Remote Management


Table 9-11 describes the commands you can use to restrict various remote management meth-
ods. The following sections cover each in detail.

Table 9-11 Telnet, HTTP, SNMP, and NTP Access Can Be Restricted

Command Configuration Mode Description

access-class access-list Line configuration Evaluates inbound or outbound vir-


in | out mode tual terminal traffic against a standard
access list.

ip http access-class Global configuration Evaluates inbound connections to the


access-list mode HTTP server against a standard access
list.

username name access- Global configuration Evaluates inbound traffic against a


class access-list mode standard or extended access list during
user authentication.

snmp community Global configuration Evaluates SNMP traffic for a particu-


string [ro | rw | view] mode lar community against a standard
access-list access list. Level of access (read only,
read-write, view only) to a single com-
munity string can be controlled using
multiple access lists.

ntp access-group peer | Global configuration Grants appropriate permissions to Net-


query-only | serve | mode work Time Protocol (NTP) processes
serve-only access-list according to access list membership.
1439_CCNP_3.book Page 594 Monday, November 15, 2004 10:35 AM

594 Chapter 9: Monitoring and Security

Restricting vty Connections


Remote access to a switch can be controlled using access lists. The line configuration com-
mand access-class access-list can be used to limit virtual terminal sessions to those matching
a predefined standard or extended access list.

Restricting Web Interface Connections


Web management interface sessions can be controlled using the global configuration com-
mand ip http access-class access-list, where access-list refers to a standard access list num-
ber between 1 and 99. It is not possible to control access to the web management interface
using extended access lists.

Restricting Specific Users


The global configuration command user username access-class access-list is used to limit a
specific user to traffic patterns defined by an access list. The parameter access-list can refer to
a standard access list in the ranges 1 to 99 or 1300 to 1999, or to an extended access list in the
ranges 100 to 199 or 2000 to 2699. This feature can also be used to control user access to a
dial-in access server.

Restricting Access to SNMP and NTP Processes


Standard access lists can also be used to control traffic relating to other management pro-
cesses running on the switch. Access to SNMP community strings can be restricted to read-
only, read-write, or view-only according to membership of standard access lists. Access to
NTP processes can also be controlled using standard access lists.

Lab 9.9.8 Restricting Virtual Terminal Sessions with Access Lists


In this lab exercise, you define and apply access lists to restrict access to virtual
terminal sessions on the switch.

Interactive Media Activity Checkbox: Security for Web Management Interface


After completing this Interactive Media Activity, you will better understand security
for the web management interface.
1439_CCNP_3.book Page 595 Monday, November 15, 2004 10:35 AM

Securing Remote Management 595

Additional Remote Management Session Options


Remote management sessions can be enhanced using the following optional messages:
■ Message-of-the-day
■ Vacant message
■ Refuse message
These messages are usually defined as explanatory notes to users. They can be applied to con-
sole, auxiliary, and vty lines, as defined in Table 9-12. Note that these message settings are
superseded if the switch has AAA enabled, because AAA can display similar messages.

Table 9-12 Message-of-the-Day, Vacant Messages, and Refuse Messages Are Used to Further
Define User Access

Command Configuration Mode Description

banner motd Global configuration Defines the message-of-the-day banner


$ Message $ mode message.

motd-banner Line configuration mode Enables the use of the message-of-the-day


banner message on one or more lines.

vacant-message Line configuration mode Defines the vacant message for one or
$ Message $ more lines.

refuse-message Line configuration mode Defines the refuse message for one or
$ Message $ more lines.

Message-of-the-Day Banner
The message-of-the-day banner is displayed when a user establishes a connection to the
switch. The actual message is defined using the global configuration command banner motd.
Example 9-16 shows a sample message-of-the-day banner. It is not recommended that the
name of the organization that owns the device be included in the banner message.

Example 9-16 The Message-of-the-Day Banner Is Normally Used to Warn Users of Unauthorized Access

This is a protected system


Any attempt at unauthorized access will be logged and reported to the relevant
authorities

User Access Verification

Username:
1439_CCNP_3.book Page 596 Monday, November 15, 2004 10:35 AM

596 Chapter 9: Monitoring and Security

After you create the message-of-the-day banner, you need to bind it to one or more lines
using the line configuration command motd-banner.

Vacant Message
The vacant message is displayed when the user session is disconnected:
ALSwitch1#exit

Session Disconnected.

The message displayed is defined using the vacant-message line configuration command.

Refuse Message
The refuse message is displayed to the user when his or her authentication fails at login. The
refuse message is defined using the line configuration command refuse-message.
Note that these message options may not be displayed for users connecting to the switch
over SSH.

Configuring, Verifying, and Troubleshooting SSH Server


Before you configure SSH, perform the following tasks:
Step 1 Download the required image on the device. The SSH server requires the
IPSec (DES or 3DES) encryption software image. The SSH client requires the
IPSec (DES or 3DES) encryption software image.
Step 2 Configure a host name and host domain for the device using the following
commands:
hostname host-name
ip domain-name domain-name

For example:
switch(config)#hostname ALSwitch1
ALSwitch1#ip domain-name abc.com

The results in the running config are as follows:


hostname ALSwitch1
!
ip domain-name abc.com

Step 3 Generate an RSA key pair for the device using the configuration line command
crypto key generate rsa. This also automatically enables SSH.
1439_CCNP_3.book Page 597 Monday, November 15, 2004 10:35 AM

Securing Remote Management 597

Step 4 Configure a local username and password on the device using the following
commands:
username name secret password
login local

For example:
ALSwitch1(config)#username Alice secret fantastic
ALSwitch1(config)#line vty 0 15
ALSwitch1(config-line)#login local

The results in the running config are as follows:


username Alice secret 5
$1$vBnC$kw40PgOX0yQQyM1KzOmv71

line vty 0 4
login local
line vty 5 15
login local

The device may also be configured with TACACS+ or RADIUS protocols for
user authentication.
You can verify SSH configuration using the following commands:
■ show ip ssh—Verifies that the SSH server is enabled, and displays the version and con-
figuration data.
■ show ssh—Displays details of users connected to the SSH server process running on
the device.

SSH Configuration Errors


SSH configuration commands are rejected if an RSA key pair was not successfully generated
first. To resolve this problem, generate a new RSA key pair. If necessary, zeroize any existing
RSA key pair using the crypto key zeroize rsa command first.
The error messages no hostname specified and no domain specified during the generation
of an RSA key pair are caused by the lack of a hostname or host domain in the switch’s run-
ning configuration. These elements of a device’s configuration are used to generate an RSA
key pair. This problem can be resolved by ensuring that both the hostname and the host
domain have been configured before an RSA key pair is generated.
Because an SSH session uses a vty resource on an SSH server, the number of simultaneous
SSH sessions is limited by the number of vty lines available on the device. Cisco IOS-based
switches support up to 16 simultaneous vty sessions.
1439_CCNP_3.book Page 598 Monday, November 15, 2004 10:35 AM

598 Chapter 9: Monitoring and Security

SSH Connection Errors


There are two main reasons for an SSH server to refuse a connection request:
■ No vty resources remain to allocate to a new vty session. The maximum number of vty
sessions hosted by the SSH server has been reached.
■ The public portion of the RSA key pair held on the client no longer matches the private
portion of the RSA key pair held on the server. This is the case only when the RSA key
pair on the SSH server has been zeroized and regenerated. This problem is resolved
by deleting the old public key on the client and downloading a copy of the new public
key from the SSH server on the switch.

Securing User Access


Management traffic is not the only traffic that needs to be secured in corporate networks. Dif-
ferent types of user traffic, such as user traffic from different parts of the organization, should
be separated from each other. User traffic should also be kept separate from management
traffic.
User traffic can be controlled using
■ VLANs
■ Port security
■ Protected ports and private VLANs
■ ACLs

Using Port Security, Protected Ports, and Private VLANs


Port security is an IOS feature available on the 6500 series, 3550 series, and 2950 series of
Catalyst switches. The port security feature can be used to restrict input to an interface by
limiting and identifying the MAC addresses of the stations allowed access to the port. When
secure MAC addresses are assigned to a secure port, the port does not forward packets with
source addresses outside the group of defined addresses. By limiting the number of secure
MAC addresses to one and assigning a single secure MAC address to the port, the worksta-
tion attached to that port is assured the port’s full bandwidth.
If a port is configured as a secure port and the maximum number of secure MAC addresses is
reached, when an additional station attempts to access the port, a security violation is logged.
Also, if a station with a secure MAC address configured or learned on one secure port
attempts to access a different secure port, a violation is flagged.
1439_CCNP_3.book Page 599 Monday, November 15, 2004 10:35 AM

Securing User Access 599

Operation of Port Security


After the maximum number of secure MAC addresses on a port (the range is 1 to 128 with a
default of 128) has been configured, the secure addresses are included in an address table in
one of the following ways:
■ Manual configuration of all secure MAC addresses by using the switchport port-
security mac-address mac_address interface configuration command.
■ The port dynamically configures secure MAC addresses with the MAC addresses of NOTE
connected devices. If a port shuts down, all
dynamically learned
■ Manual configuration of a number of addresses, with the remainder to be configured addresses for that port
dynamically. are removed.

As soon as the maximum number of secure MAC addresses is configured, they are stored in
an address table. Setting the maximum number of addresses to 1 and configuring the MAC
address of an attached device ensures that the device has the port’s full bandwidth.

Port Security Violations


A security violation occurs in the following situations:
■ The maximum number of secure MAC addresses has been added to the address table,
and a station whose MAC address is not in the address table attempts to access the
interface.
■ A station whose MAC address is configured as secure on another secure port attempts
to access the interface.
The interface can be configured for one of three violation modes, based on the action to be
taken if a violation occurs:
■ Shutdown—A port security violation causes the interface to shut down immediately,
and send an SNMP trap notification. After it is shut down, the interface must be manu-
ally re-enabled by using the no shutdown interface configuration command. This is the
default mode when port security is enabled.
■ Protect—When the number of secure MAC addresses reaches the maximum limit
allowed on the port, packets with unknown source addresses are dropped until secure
MAC addresses are manually removed from the port’s address table to create a free
slot.
■ Restrict—A port security violation causes a trap notification to be sent to the SNMP
network management station.
By default, port security is disabled on a port. Port security defaults are a maximum of 128
secure MAC addresses per port and shutdown on security violation.
1439_CCNP_3.book Page 600 Monday, November 15, 2004 10:35 AM

600 Chapter 9: Monitoring and Security

Protected Ports
Protected ports do not forward any traffic to other protected ports on the same switch. This
means that all traffic passing between protected ports (unicast, broadcast, and multicast) must
be forwarded through a Layer 3 device. Protected ports can forward any type of traffic to
unprotected ports, and they forward as usual to all ports on other switches.
This functionality is available on the Catalyst 2950 series and 3550 series switches. The
Catalyst 6500 series switch uses a technology called private VLANs. Although protected
ports and private VLANs are conceptually the same, configuring private VLANs on the Catalyst
6500 series switch is significantly different from configuring protected ports on the Catalyst 2950
series and Catalyst 3550 series switches.
This section covers the configuration of protected ports on 2950 series and 3550 series
switches. Refer to Cisco.com for information on configuring private VLANs on Catalyst
6500 series switches.
Protected ports provide Layer 2 isolation between ports within the same VLAN and have two
common features:
■ A protected port that does not forward any traffic (unicast, multicast, or broadcast) to
any other port that is also a protected port. Traffic cannot be forwarded between pro-
tected ports at Layer 2. All traffic passing between protected ports must be forwarded
through a Layer 3 device.
■ Forwarding behavior between a protected port and an unprotected port proceeds as usual.
The factory default is that no protected ports are configured.
There could be times when unknown unicast or multicast traffic from an unprotected port is
flooded to a protected port, because a MAC address has timed out or has not been learned by
the switch. Using the commands switchport block unicast and switchport block multicast
guarantees that no unicast and multicast traffic is flooded to the port under these conditions.

Using Access Lists


Packet filtering can help limit network traffic and restrict network use by certain users or
devices. ACLs can filter traffic as it passes through a switch and permit or deny packets at
specified interfaces. This chapter has also shown how ACLs can be deployed to control
management sessions for remote control of the switch.
Recall that an ACL is a sequential collection of permit and deny conditions that apply to
packets. When a packet is received on an interface, the switch compares the packet’s fields
against any applied ACLs to verify that the packet has the required permissions to be for-
warded, based on the criteria specified in the access lists. The switch tests packets against the
conditions in an access list one by one. The first match determines whether the switch accepts
1439_CCNP_3.book Page 601 Monday, November 15, 2004 10:35 AM

Securing User Access 601

or rejects the packets. Because the switch stops testing conditions after the first match, the order
of conditions in the list is critical. If no conditions match, the switch rejects the packets. If there
are no restrictions, the switch forwards the packet; otherwise, the switch drops the packet.
Switches traditionally operate at Layer 2 only, switching traffic within a VLAN, whereas
routers route traffic between VLANs. The Catalyst 3550 switch can accelerate packet routing
between VLANs by using Layer 3 switching. The switch bridges the packet, the packet is
then routed internally without going to an external router, and then the packet is bridged
again to send it to its destination. During this process, the switch can use ACLs to filter all
data it switches, including data bridged within a VLAN.
ACLs can be configured on a router or switch to provide basic security for a network. If ACLs
are not configured, all packets passing through the switch could be allowed onto all parts of
the network. ACLs can be used to control which hosts can access different parts of a network
or to decide which types of traffic are forwarded or blocked at router interfaces. For example,
an ACL might be configured to allow e-mail traffic but not Telnet traffic. Layer 3 ACLs can be
configured to filter inbound traffic, outbound traffic, or both. ACLs on Layer 2 interfaces can
filter only inbound traffic.
An ACL contains an ordered list of access control entries (ACEs). Each ACE specifies a set
of conditions the data must match and a permit or deny action to perform when a match is
found. The meaning of the permit or deny action depends on the context in which the ACL
is used.
The 3550 switch supports two types of ACLs:
■ IP ACLs to filter IP traffic at Layer 3, including TCP, UDP, Internet Group Management
Protocol (IGMP), and Internet Control Message Protocol (ICMP).
■ Ethernet or MAC ACLs to filter traffic at Layer 2.
The switch supports three applications of ACLs to filter traffic:
■ Router ACLs filter routed traffic between VLANs and are applied to Layer 3 interfaces
based on the following criteria:
— Source address(es)
— Destination address(es)
— Source IP port(s)
— Destination IP port(s)
— Individual host address
— Address range or pattern
— Port range
— Inbound/outbound/bidirectional traffic
1439_CCNP_3.book Page 602 Monday, November 15, 2004 10:35 AM

602 Chapter 9: Monitoring and Security

One router ACL can be applied in each direction on an interface.


■ Port ACLs filter traffic entering a Layer 2 interface. The switch does not support port
ACLs in the outbound direction. Only one IP access list and one MAC access list to a
Layer 2 interface can be applied.
■ VLAN ACLs or VLAN maps filter all packets (bridged and routed). VLAN maps are
used to filter traffic between devices in the same VLAN or to provide Layer 3 access
control based on IP addresses. Unsupported protocols are filtered through MAC
addresses by using Ethernet ACEs. After a VLAN map is applied to a VLAN, all pack-
ets (routed or bridged) entering the VLAN are checked against the VLAN map. Packets
can enter the VLAN either through a switch port at Layer 2 or through a routed port
after being routed at Layer 3.
Both router ACLs and VLAN maps can be used on the same switch. However, port ACLs
cannot be used on a switch that contains VLAN maps or inbound router ACLs.
When a switch has a Layer 2 interface with an applied IP ACL or MAC ACL, IP ACLs and
VLAN maps can be created. However, an IP ACL cannot be applied to an input Layer 3 inter-
face on that switch. Also, a VLAN map cannot be applied to any of the switch VLANs; an
error message is generated if this is attempted. An IP ACL can still be applied to an output
Layer 3 interface on a switch with port ACLs.
When a switch has an input Layer 3 ACL or a VLAN map applied to it, an IP ACL or MAC
ACL cannot be applied to a Layer 2 interface on that switch; an error message is generated if
this is attempted. However, a port ACL can be applied if the switch has an ACL applied only
to an output Layer 3 interface.
If 802.1Q tunneling is configured on an interface, any 802.1Q encapsulated IP packets
received on the tunnel port can be filtered by MAC ACLs at Layer 2, but not by IP ACLs at
Layer 3. This is because the switch does not recognize the protocol inside the 802.1Q header.
This restriction applies to router ACLs, port ACLs, and VLAN maps.

Router ACLs
Router ACLs can be applied on the following interface types:
■ Switch virtual interfaces (SVIs), which are Layer 3 interfaces to VLANs
■ Physical Layer 3 interfaces
■ Layer 3 EtherChannel interfaces
Router ACLs are applied on interfaces for specific directions (inbound or outbound). One IP
ACL in each direction can be specified.
1439_CCNP_3.book Page 603 Monday, November 15, 2004 10:35 AM

Securing User Access 603

One ACL can be used with multiple features (such as QoS) for a given interface, and one fea-
ture can use multiple ACLs. When a single router ACL is used by multiple features, it is
examined multiple times.
Standard IP ACLs use source addresses for matching operations.
Extended IP ACLs use source and destination addresses and optional protocol type informa-
tion for matching operations.
The switch examines ACLs associated with features configured on a given interface and
direction. As packets enter the switch on an interface, ACLs associated with all inbound fea-
tures configured on that interface are examined. After packets are routed and before they are
forwarded to the next hop, all ACLs associated with outbound features configured on the
egress interface are examined.
ACLs permit or deny packet forwarding based on how the packet matches the entries in
the ACL. For example, ACLs can be used to allow one host to access part of a network and
prevent another host from accessing the same part. As shown in Figure 9-25, ACLs applied at
the router input allow Host A to access the Human Resources network and prevent Host B
from accessing the same network.

Figure 9-25 Routed Traffic Is Filtered with a Router ACL

Host A
X
Catalyst 3550 Switch
With Enhanced
Multilayer Software
Image
Host B
Human Research and
Resources Development
Network Network

= ACL Denying Traffic From Host B and


X Permitting Traffic From Host A

= Packet
1439_CCNP_3.book Page 604 Monday, November 15, 2004 10:35 AM

604 Chapter 9: Monitoring and Security

Port ACLs
ACLs can also be applied to Layer 2 interfaces on a switch. Port ACLs are supported on phys-
ical interfaces only, not on EtherChannel interfaces. Port ACLs are applied on interfaces for
inbound traffic only.
The following port ACLs are supported on Layer 2 interfaces:
■ Standard IP ACLs using source addresses
■ Extended IP ACLs using source and destination addresses and optional protocol type
information
■ MAC extended ACLs using source and destination MAC addresses and optional proto-
col type information
Similar to router ACLs, with port ACLs, the switch examines ACLs associated with features
configured on a given interface and permits or denies packet forwarding based on how the
packet matches the entries in the ACL.
However, ACLs can be applied only to Layer 2 interfaces in the inbound direction. For
instance, in the network setup shown in Figure 9-25, if all workstations were in the same
VLAN, ACLs applied at the Layer 2 input would allow Host A to access the Human
Resources network and prevent Host B from accessing the same network.
When a port ACL is applied to a trunk port, the ACL filters traffic on all VLANs present on
the trunk port. When a port ACL is applied to a port with voice VLAN, the ACL filters traffic
on both data and voice VLANs.
With port ACLs, IP traffic can be filtered using IP ACLs. Using MAC ACLs permits non-IP
traffic to be filtered. Both IP and non-IP traffic can be filtered on the same Layer 2 interface
by applying both an IP ACL and a MAC ACL to the interface.
Only one IP ACL and one MAC ACL can be applied to a Layer 2 interface. If an IP ACL or
MAC ACL is already configured on a Layer 2 interface and a new IP ACL or MAC ACL is
applied to the interface, the new ACL replaces the previously configured one.

VLAN ACLs and VLAN Maps


VLAN maps, also known as VLAN ACLs or VACLs, can filter all traffic traversing a switch.
VLAN maps can be configured on the switch to filter all packets that are routed into or out of
a VLAN or that are bridged within a VLAN. VLAN maps are used strictly for security packet
filtering. Unlike router ACLs, VLAN maps are not defined by direction (input or output).
1439_CCNP_3.book Page 605 Monday, November 15, 2004 10:35 AM

Securing User Access 605

VLAN maps can be configured to filter on packet characteristics and Layer 3 and Layer 4. All
non-IP protocols are filtered through MAC addresses and Ethertype using MAC VLAN maps
(IP traffic is not filtered by MAC VLAN maps). VLAN maps can be enforced only on packets
going through the switch; VLAN maps cannot be enforced on traffic between hosts on a hub
or on another switch connected to this switch.
With VLAN maps, forwarding of packets is permitted or denied based on the action specified
in the map. VLAN maps use match clauses to select traffic and perform operations on it. Each
clause contains one or more access lists, each of which uses permit and deny actions to select
or ignore traffic. VLAN maps are like access lists made up of other access lists. Figure 9-26
illustrates how a VLAN map is applied to deny a specific type of traffic from Host A in
VLAN 10 from being forwarded.

Figure 9-26 Intra-VLAN Traffic Is Filtered with VLAN Maps

Host A Catalyst 3550 Switch Host B


(VLAN 10) Bridging Traffic (VLAN 10)

VLAN maps are the only way to control filtering within a VLAN. VLAN maps have no direc-
tion. That is, unlike IP ACLs, VLAN maps do not differentiate between inbound and out-
bound traffic. To filter traffic in a specific direction using a VLAN map, you need to include
an ACL with specific source or destination addresses. If there is a match clause for a type of
packet (IP or MAC) in the VLAN map, and that packet does not match any of the entries in
the map, the default VLAN map action is to drop the packet. If there is no match clause for
that type of packet, the default is to forward the packet.
Before creating the VLAN map, create the standard or extended IP ACLs or named MAC
extended ACLs to be applied to the VLAN. This ACL selects the traffic that will be either for-
warded or dropped by the access map. Only traffic matching the permit condition in an ACL
is passed to the access map for further processing.
To create a VLAN map and apply it to one or more VLANs, follow the steps shown in
Table 9-13.
1439_CCNP_3.book Page 606 Monday, November 15, 2004 10:35 AM

606 Chapter 9: Monitoring and Security

Table 9-13 Configuring VLAN Maps

Step Command Description

1 configure terminal Enters global configuration mode.

2 vlan access-map name [number] Creates a VLAN map and gives it a


name and (optionally) a number.
Each VLAN map can have multiple
entries. The order of these entries is
determined by the number. If no
sequence number is entered, access
map entries are added with sequence
numbers in increments of 10.
When modifying or deleting maps,
enter the number of the map entry to be
modified or deleted.
Entering this command puts the com-
mand-line interface into access map
configuration mode.

3 action {drop | forward} In access map configuration mode,


optionally enter an action forward or
action drop. The default is to forward
traffic.

4 match {ip | mac} address {access-list Enter the match command to specify
name/number} [access-list name/ an IP packet or a non-IP packet (with
number] only a known MAC address) and to
match the packet against one or more
ACLs (standard or extended).
Note that packets are matched only
against access lists or the correct proto-
col type. IP packets are matched against
standard or extended IP access lists.
Non-IP packets are matched only
against named MAC extended access
lists.

5 vlan filter access-map-name vlan-list Use this global configuration command


vlan-list to apply a VLAN map to one or more
VLANs. A single access map can be
used on multiple VLANs.
1439_CCNP_3.book Page 607 Monday, November 15, 2004 10:35 AM

Securing User Access 607

Note that a VLAN map cannot be applied to a VLAN on a switch that has ACLs applied to
Layer 2 interfaces (port ACLs).

Lab 9.9.11 Configuring VLAN Maps


In this lab exercise, you configure VACLs for IP addresses in a common VLAN.

Configuring and Verifying Port Security


Follow these guidelines when configuring port security:
■ A protected port cannot be a routed port.
■ A secure port cannot be a dynamic access port or a trunk port.
■ A protected port cannot be a secure port.
■ A secure port cannot be a destination port for a SPAN.
■ A secure port cannot belong to a Fast EtherChannel or Gigabit EtherChannel port group.
■ A secure port cannot be an 802.1x port. Attempting to enable 802.1x on a secure
port results in an error message, and 802.1x is not enabled. Attempting to change an
802.1x-enabled port to a secure port also results in an error message, and the security
settings are not changed.
Beginning in privileged EXEC mode, follow the steps listed in Table 9-14 to restrict input to
an interface using port security.

Table 9-14 Port Security Can Be Used to Shut Down a Port Upon Unauthorized Access
Attempts

Step Command Description

1 configure terminal Enters global configuration mode.


2 interface interface-id Enters interface configuration mode for
the physical interface to be configured
(GigabitEthernet0/1, for example).

3 switchport mode access Sets the interface mode as access; an


interface in the default mode (dynamic
desirable) cannot be configured as a
secure port.

4 switchport port-security maximum- (Optional) Sets the maximum number


number-of-addresses of secure MAC addresses for the inter-
face. The range is 1 to 128. The default
is 128.
continues
1439_CCNP_3.book Page 608 Monday, November 15, 2004 10:35 AM

608 Chapter 9: Monitoring and Security

Table 9-14 Port Security Can Be Used to Shut Down a Port Upon Unauthorized Access
Attempts (Continued)

Step Command Description

5 switchport port-security violation (Optional) Sets the violation mode, the


{protect | restrict | shutdown} action to be taken when a security
violation is detected as one of the
following:
shutdown—The interface shuts down
immediately, and an SNMP trap notifi-
cation is sent. When shut down, the
interface must be manually re-enabled
by using the no shutdown interface
configuration command. shutdown is
the default mode.
restrict—A trap notification is sent to
the network management station.
protect—When the number of port
secure MAC addresses reaches the
maximum limit allowed on the port,
packets with unknown source addresses
are dropped until you remove a suffi-
cient number of secure MAC addresses
to drop below the maximum value.

6 switchport port-security mac-address (Optional) Enters a secure MAC


mac-address address for the interface. You can use
this command to enter the maximum
number of secure MAC addresses. If
you configure fewer secure MAC
addresses than the maximum, the
remaining MAC addresses are dynami-
cally learned.

7 end Returns to privileged EXEC mode.

8 show port-security interface Verifies the entries.


interface-id

show port-security address Verifies the entries.

9 copy running-config startup-config (Optional) Saves the entries in the con-


figuration file.
1439_CCNP_3.book Page 609 Monday, November 15, 2004 10:35 AM

Securing User Access 609

To return the interface to the default condition (a nonsecure port), use the no switchport
port-security interface configuration command.
To return the interface to the default number of secure MAC addresses (128), use the no
switchport port-security maximum maximum-number-of-addresses interface configuration
command.
To delete a MAC address from the address table, use the no switchport port-security
mac-address mac_address command.
To return the violation mode to the default condition (shutdown mode), use the no switch-
port port-security violation {protect | restrict} command.
The show interfaces interface-id switchport privileged EXEC command displays the inter-
face traffic suppression and control configuration.
The show interfaces counters privileged EXEC command displays the count of discarded
packets.
The show storm control and show port-security privileged EXEC commands display those
features.

Lab 9.9.10 Configuring Protected Ports


In this lab exercise, you configure private VLAN edge protected ports.

Interactive Media Activity Drag and Drop: Catalyst Port Security


After completing this Interactive Media Activity, you will better understand port
security configuration.

Configuring and Verifying Protected Ports


Starting in privileged EXEC mode, follow the steps listed in Table 9-15 to define a port as a
protected port.
1439_CCNP_3.book Page 610 Monday, November 15, 2004 10:35 AM

610 Chapter 9: Monitoring and Security

Table 9-15 By Default, Traffic Is Not Forwarded Between Protected Ports Without the Intervention
of a Layer 3 Device

Step Command Description

1 configure terminal Enters global configuration mode.

2 interface interface-id Enters interface configuration mode for


the physical interface to be configured
(GigabitEthernet0/1, for example).

3 switchport protected Configures the interface to be a pro-


tected port.

4 end Returns to privileged EXEC mode.


5 show interface interface-id switchport Verifies your entries.

To disable a protected port, use the no switchport protected interface configuration command.

Interactive Media Activity Checkbox: Catalyst Protected Port


After completing this Interactive Media Activity, you will better understand the
configuration of protected ports.

Configuring and Verifying Access Lists


This section describes how to create switch ACLs. Recall that the switch tests packets against
the conditions in an ACL one by one. The first match determines whether the switch accepts
or rejects the packet. Because the switch stops testing conditions after the first match, the
order of the conditions is critical. If no conditions match, the switch denies the packet.
Follow these steps to use ACLs:
Step 1 Create an ACL by specifying an access list number (see Table 9-16) or name
and access conditions.
Step 2 Apply the ACL to interfaces or terminal lines.
Cisco IOS-based switches support the following types of IP ACLs:
■ Standard IP ACLs using source addresses for matching operations.
■ Extended IP ACLs using source and destination addresses for matching operations and
optional protocol-type information for finer granularity of control.
1439_CCNP_3.book Page 611 Monday, November 15, 2004 10:35 AM

Securing User Access 611

Table 9-16 At Least 15 Different ACL Ranges Are Available for IOS Filtering

ACL Number Type Supported?

1 to 99 IP standard access list Yes

100 to 199 IP extended access list Yes

200 to 299 Protocol type-code access list No

300 to 399 DECnet access list No

400 to 499 XNS standard access list No

500 to 599 XNS extended access list No

600 to 699 AppleTalk access list No

700 to 799 48-bit MAC address access list No

800 to 899 IPX standard access list No


900 to 999 IPX extended access list No

1000 to 1099 IPX SAP access list No

1100 to 1199 Extended 48-bit MAC address access list No

1200 to 1299 IPX summary address access list No

1300 to 1399 IP standard access list (expanded range) Yes

2000 to 2699 IP extended access list (expanded range) Yes

MAC extended ACLs use source and destination MAC addresses and optional protocol type
information for matching operations.
In addition to numbered standard and extended ACLs, named standard and extended IP ACLs
can be created. The advantage of using named ACLs instead of numbered lists is that individ-
ual entries can be deleted from a named list.
ACLs can be applied to any management interface, such as the switch virtual interface on a
Catalyst 2950T.
The limitations that apply to ACLs on physical interfaces do not apply to ACLs on manage-
ment interfaces.
1439_CCNP_3.book Page 612 Monday, November 15, 2004 10:35 AM

612 Chapter 9: Monitoring and Security

After creating an ACL, you can apply it to one or more interfaces or terminal lines. You can
also apply ACLs on inbound interfaces. This section describes how to accomplish this task
for both terminal lines and network interfaces. Keep the following guidelines in mind:
■ When controlling access to a line, numbered IP ACLs or MAC extended ACLs must
be used.
■ When controlling access to an interface, named or numbered ACLs can be used.
■ Set identical restrictions on all the virtual terminal lines, because a user can attempt to
connect to any of them.
■ If applying ACLs to a management interface, the ACL filters only packets that are
intended for the CPU, such as SNMP, Telnet, or web traffic.
Beginning in privileged EXEC mode, follow the steps listed in Table 9-17 to restrict incom-
ing connections between a virtual terminal line and the addresses in an ACL.

Table 9-17 The Access Class Can Be Used to Restrict Access on Console and vty Lines

Step Command Description

1 configure terminal Enters global configuration mode.

2 line | console | vty | line-number Identifies a specific line for configura-


tion and enters in-line-configuration
mode.
Enter console for the console terminal
line. The console port is DCE.
Enter vty for a virtual terminal for
remote console access.
The line-number is the first line number
in a contiguous group that you want to
configure when the line type is speci-
fied. The range is from 0 to 16.

3 access-class access-list-number {in} Restricts incoming and outgoing con-


nections between a particular virtual
terminal line (into a device) and the
address in an access list.

4 end Returns to privileged EXEC mode.

5 show running-config Displays the access list configuration.


1439_CCNP_3.book Page 613 Monday, November 15, 2004 10:35 AM

Securing User Access 613

Beginning in privileged EXEC mode, follow the steps listed in Table 9-18 to control access to
a Layer 2 interface.

Table 9-18 A Port ACL Is Applied to a Layer 2 Interface

Step Command Description

1 configure terminal Enters global configuration mode.

2 interface interface-id Identifies a specific line for configura-


tion and enters in-line-configuration
mode. The interface must be a Layer 2
or management interface or a manage-
ment interface VLAN ID.

3 ip access-group {access-list-number/ Controls access to the specified


name} {ia} interface.

4 end Returns to privileged EXEC mode.

5 show running-config Displays the access list configuration.

Use the commands listed in Table 9-19 to display the ACLs that are configured on the switch
and to display the ACLs that have been applied to physical and management interfaces.

Table 9-19 The show access-lists Command Is Extremely Useful for Displaying Configured Access
List Information

Command Description

show access-lists [number/name] Displays information about all IP and MAC


address access lists or about a specific access list
(numbered or named).

show ip access-lists [number/name] Displays information about all IP address access


lists or about a specific access list (numbered or
named).
1439_CCNP_3.book Page 614 Monday, November 15, 2004 10:35 AM

614 Chapter 9: Monitoring and Security

Authentication, Authorization, and Accounting (AAA)


AAA is an architectural framework for configuring three different security features:
■ Authentication—Supplying user credentials to gain access to a system. Authentication
asks the user who he is.
■ Authorization—Limiting a user’s access to certain “authorized” commands and
options. Authorization asks the user what privileges he has.
■ Accounting—Recording user activity for security, billing, or other purposes. Account-
ing records what the user did and when he did it.
Configuring a local database of usernames and passwords on the switch has already been
covered in this chapter. AAA can also be used for login authentication. Using AAA for device
logins offers three main advantages:
■ AAA provides scalability—Many Cisco IOS devices can use AAA to refer to a
common set of usernames and passwords on a central security server.
■ AAA supports standardized protocols—Cisco IOS devices running AAA can
communicate securely with security servers using protocols such as TACACS+ and
RADIUS.
■ AAA allows for multiple backup systems—Cisco IOS devices can consult a second
or third source of information if the primary source of security information is offline.
Overall, these benefits mean that AAA provides scalability as well as increased flexibility and
control of access configuration.
Network hosts are often configured to use a security protocol, as shown in Figure 9-27.

Figure 9-27 A Network Access Server Configured for AAA Can Authenticate and Authorize Remote
Users Via TACACS+ or RADIUS

RADIUS
Server

TACACS+
Server
Remote NAS
PC

Workstation
1439_CCNP_3.book Page 615 Monday, November 15, 2004 10:35 AM

Authentication, Authorization, and Accounting (AAA) 615

Hosts use a security protocol to communicate with a specialized security server. The security
server maintains a password and username database, as well as authorization configurations,
and stores accounting information. Cisco IOS supports three key security protocols:
■ TACACS+
■ RADIUS
■ Kerberos
TACACS+ is a security application used with AAA that provides centralized validation of
users attempting to gain access to a router or network access server. TACACS+ services are
maintained in a database on a TACACS+ daemon running, typically, on a UNIX or Windows
NT workstation. TACACS+ provides for separate and modular authentication, authorization,
and accounting facilities.
RADIUS is a distributed client/server system used with AAA that secures networks against
unauthorized access. In the Cisco implementation, RADIUS clients run on Cisco routers and
send authentication requests to a central RADIUS server that contains all user authentication
and network service access information.
Kerberos is a secret-key network authentication protocol used with AAA that uses the
Encryption Standard (DES) cryptographic algorithm for encryption and authentication. Ker-
beros was designed to authenticate requests for network resources. It is based on the concept
of a trusted third party that performs secure verification of users and services. The primary
use of Kerberos is to verify that users and the network services they use are really who and
what they claim to be. To accomplish this, a trusted Kerberos server issues tickets to users.
These tickets, which have a limited life span, are stored in a user’s credentials cache and can
be used in place of the standard username and password authentication mechanism.
Of the three protocols, TACACS+ and RADIUS offer the most comprehensive AAA support.
Kerberos provides a highly secure method of authentication, in which passwords are never
sent over the wire. Kerberos does not support the authorization and accounting components
of AAA and, therefore, is not covered in any detail in this chapter.
The following sections examine TACACS+ and RADIUS in detail. Table 9-20 compares the
features of each.

TACACS+
TACACS+ provides the most comprehensive and flexible security configurations when using
Cisco routers and switches. TACACS+ is derived from the TACACS and extended TACACS
protocols. Both of these older protocols are considered “deprecated” protocols, which means
that they are no longer seen as viable solutions. A Cisco-proprietary protocol, TACACS+ is
incompatible with TACACS and extended TACACS.
1439_CCNP_3.book Page 616 Monday, November 15, 2004 10:35 AM

616 Chapter 9: Monitoring and Security

Table 9-20 TACACS+ Versus RADIUS

TACACS+ RADIUS

A Cisco-proprietary enhancement to An open standard developed by Livingston


the original TACACS protocol. Enterprises.

Supports AAA functions. Supports AAA functions.

Uses the AAA architecture, which sep- Combines the functions of authentication,
arates authentication, authorization, authorization, and accounting.
and accounting.

Provides two ways to control the autho- Does not allow administrators to control which
rization of router commands on a per- commands can be executed on a router.
user or per-group basis.
Uses TCP. Uses UDP.

Normal operation fully encrypts the Encrypts only the password in the access
body of the packet for more secure request packet. Information such as username,
communications. authorization services, and accounting could be
captured by a third party.

TACACS+ uses TCP to communicate between a TACACS+ server and a TACACS+ client, as
shown in Figure 9-28. Use of TACACS+ is required to take advantage of all the features of
AAA. Unlike RADIUS, TACACS+ separates the functions of authentication, authorization,
and accounting.

RADIUS
The RADIUS protocol is a client/server protocol developed by Livingston Enterprises as an
authentication and accounting protocol for use with access servers. RADIUS is specified in
RFCs 2865, 2866, and 2868. Even though TACACS+ offers more flexible AAA configura-
tions, RADIUS is a popular AAA solution. Because it is an open standard, it typically uses
fewer CPU cycles and is less memory-intensive than the proprietary TACACS+. RADIUS is
currently the only security protocol supported by emerging wireless authentication protocols.
Communication between a network device and a RADIUS server is based on UDP. Gener-
ally, the RADIUS protocol is considered a connectionless service. Issues related to server
availability, retransmission, and timeouts are handled by the RADIUS-enabled devices rather
than by the transmission protocol. Typically, the RADIUS protocol retries a transmission if a
response is not received within a specified timeout period.
1439_CCNP_3.book Page 617 Monday, November 15, 2004 10:35 AM

Authentication, Authorization, and Accounting (AAA) 617

Figure 9-28 By Default, Traffic Is Not Forwarded Between Protected Ports Without the Intervention
of a Layer 3 Device

I am user plee, password


1234. Please let me in. Corporate
Network

TCP 49
NAS

Is it ok to authenticate
user plee password 1234

UNIX Host
Running TACACS+

The RADIUS client is typically a network device, such as a network access server (NAS), a
LAN switch, or a network router. The RADIUS server is usually a daemon process running
on a UNIX machine or a service running on a Windows machine. The client passes user
information to designated RADIUS servers and waits for a response. The RADIUS server
receives the user connection request, authenticates the user, and returns the configuration
information—accept, reject, or challenge—necessary for the client to deliver service to the
user. Figure 9-29 illustrates the transactions between a client and a RADIUS server. A
RADIUS server can also act as a proxy client to other RADIUS servers and other kinds of
authentication servers.
Today, the emerging Extensible Authentication Protocol (EAP) relies on RADIUS services.
EAP with RADIUS makes it possible to use various authentication methods on a network
that are not supported by the NAS. This means that customers can use standard authentication
mechanisms, such as random key tokens, smart cards, and public keys, to strengthen end-user
and device-authenticated access to networks.
Variants of EAP, such as Cisco Lightweight Extensible Authentication Protocol (LEAP) and
the standards-based Protected Extensible Authentication Protocol (PEAP), provide dynamic
per-user, per-session Wired Equivalent Privacy (WEP) key enhancements to mitigate a vari-
ety of wireless network attacks. As more network professionals turn to EAP, LEAP, and
PEAP to better secure their networks, RADIUS deployments will increase.
1439_CCNP_3.book Page 618 Monday, November 15, 2004 10:35 AM

618 Chapter 9: Monitoring and Security

Figure 9-29 RADIUS Was Originally Designed for Dialup Clients

RADIUS Client
Dial
Modem 4
1 5
2 RADIUS
3 Server
6

• User initiates PPP authentication to the NAS.


• NAS prompts for username and password (if PAP or challenge (if CHAP).
• User replies.
• RADIUS client sends username and encrypted password to the RADIUS server.
• RADIUS server responds with Accept, Reject, or Challenge.
• RADIUS client acts upon service and services parameters bundled with Accept or Reject.

Cisco Secure Access Control Server (ACS)


The Cisco Secure Access Control Server (ACS), shown in Figure 9-30, is specialized security
software that runs on Windows 2000. Earlier versions of ACS (before ACS 3.1) ran on Win-
dows NT and UNIX. The software simplifies and centralizes control of access control and
accounting for dialup access servers, virtual private networks (VPNs) and firewalls, voice
over IP (VoIP) solutions, broadband access, content networks, and wireless networks. Cisco
ACS employs a web-based graphical interface and can distribute the AAA information to
hundreds or even thousands of access points in a network.
The Cisco Secure ACS software uses either the TACACS+ or RADIUS protocol to provide
network security and tracking.
Each network device can be configured to communicate with ACS. Service providers can use
ACS to centralize control of dialup access. With a CiscoSecure ACS, system administrators
may use a variety of authentication methods that are aligned with a varying degree of authori-
zation privileges. Centralizing control of network access simplifies access management and
helps establish consistent provisioning and security policies. For example, ACS can automat-
ically disable accounts to prevent brute-force password-guessing attacks.
Cisco Secure ACS also acts as a central repository for accounting information. Each user
session that is granted by the ACS can be fully accounted for and stored in the server. This
accounting information can be used for billing, capacity planning, and security audits.
1439_CCNP_3.book Page 619 Monday, November 15, 2004 10:35 AM

Authentication, Authorization, and Accounting (AAA) 619

Figure 9-30 Cisco Secure Access Control Server Is Used for Enterprise Access Control

The web-based interface can be used to log in to the Cisco Secure ACS database and easily
create user or group accounts, set passwords, or configure access controls.

Configuring AAA
Configuring AAA can be a complex process. It is imperative that security policies are well
planned before beginning to configure AAA.
To enable AAA, issue the following command in global configuration mode:
Router(config)#aaa new-model

The aaa new-model command enables the AAA feature so that other AAA commands can be
entered. To disable AAA, use the no aaa new-model command.
Do not issue the aaa new-model command unless you’re prepared to configure AAA authen-
tication. In some cases, just issuing this command forces Telnet users to authenticate with a
username, even if no username database or authentication method is configured. If access to
the router console is unavailable, access to the router is blocked.
The following sections describe how to configure the three elements of AAA using
TACACS+, RADIUS, and local databases.
1439_CCNP_3.book Page 620 Monday, November 15, 2004 10:35 AM

620 Chapter 9: Monitoring and Security

Configuring TACACS+ and RADIUS Clients


If a TACACS+ server is used in conjunction with AAA, the device must be configured with
the address(es) of the server(s) and the TACACS+ encryption key. The encryption key must
be the same on both the TACACS+ server and its clients.
To configure the address of a TACACS+ server, use the global configuration command
tacacs-server host ip-address.
Use multiple tacacs-server host commands to specify multiple hosts. Cisco IOS software
searches for the hosts in the order specified. The tacacs-server key word global configuration
command configures the encryption key.
The following commands would be used to configure the router shown in Figure 9-31 to com-
municate with a TACACS+ server at 192.168.0.11 using the shared key topsecret:
RTA(config)#tacacs-server host 192.168.0.11
RTA(config)#tacacs-server key topsecret

Figure 9-31 Configuring a Router to Communicate with a TACACS+ Server

Corporate Network

e0 192.168.0.1

Public
Network RTA

192.168.0.11

Topsecret

UNIX Host
Running TACACS+

Use the show tacacs command to verify TACACS+ configuration and connection, as demon-
strated in Example 9-17.

Example 9-17 The show tacacs Command Displays the IP Address of the TACACS+ Server

RTA#show tacacs
Server:192.168.0.11/49; opens=4 closes=4 aborts=0 errors=0
packets in=6 packets out=6
no connection
1439_CCNP_3.book Page 621 Monday, November 15, 2004 10:35 AM

Authentication, Authorization, and Accounting (AAA) 621

Like TACACS+, devices are configured to use RADIUS by specifying a server address and
shared key.
Use the radius-server host ip-address global configuration command to specify an IP
address for the server.
Use multiple radius-server host commands to specify multiple hosts. Cisco IOS software
searches for the hosts in the order specified. Use the radius-server key word global configu-
ration command to specify the encryption key.
To configure a router to communicate with a RADIUS server at 192.168.0.22, using the
shared key topsecret, enter the following commands:
RTA(config)#radius-server host 192.168.0.22
RTA(config)#radius-server key topsecret

Configuring AAA Authentication


Authentication provides the method of identifying users, including
■ Login and password dialog
■ Challenge and response
■ Messaging support
A Cisco Catalyst switch has several different types of authentication:
■ When logging into the switch
■ When accessing privileged EXEC mode
■ When establishing a PPP connection to a router
A username and password that successfully authenticates for one type of access might not
work for another.
The basic steps to follow when configuring AAA authentication are as follows:
Step 1 Turn on aaa new-model in the switch.
Step 2 Configure AAA server group(s).
Step 3 Configure AAA login method(s).
Step 4 Attach login methods to server groups.
Step 5 Attach AAA login method(s) to line(s).
AAA authentication can be used on Cisco Catalyst 6500 series, 3550 series, and 2950 series
switches to configure the following configuration types:
■ Access to the console
■ Access to virtual terminals through Telnet and SSH connections
■ Access to privileged EXEC mode (enable mode)
1439_CCNP_3.book Page 622 Monday, November 15, 2004 10:35 AM

622 Chapter 9: Monitoring and Security

To configure access to the console, use the global configuration command aaa authentica-
tion login method.
Specify which type of authentication to configure (login, enable, PPP) when using this com-
mand. Table 9-21 lists some of the keywords used with the aaa authentication command.

Table 9-21 AAA Authentication Can Be Applied to Users Connecting Via PPP, Accessing a Line, or
Entering Privileged Mode

Keyword Description

arap Sets the authentication method for ARAP.

enable Sets the authentication method for privileged EXEC mode.

login Sets the authentication method for logins and terminal lines, virtual terminal
lines, and the console.

nasi Sets the authentication method for NetWare Access Server Interface (NASI).

ppp Sets the authentication method for any authentication protocol supported by
PPP (Challenge Handshake Authentication Protocol [CHAP], Password
Authentication Protocol [PAP], Microsoft CHAP [MS-CHAP]).

After an authentication type has been specified, define either a default method list or a named
method list. Named method lists must be applied to a specific interface before any of the
defined authentication methods are performed. The default method list is automatically
applied to all interfaces if no other method list is defined.
These lists are called “method lists,” because they list the types of authentication to be per-
formed and the sequence in which they are performed. Authentication methods include the
following:
■ Using a password already configured on the router, such as the enable password or a
line password
■ Using the local username/password database
■ Consulting a Kerberos server
■ Consulting a RADIUS server or a group of RADIUS servers
■ Consulting a TACACS+ server or group of TACACS+ servers
Note that a FAIL response is significantly different from an ERROR. A FAIL means that the
user has not met the criteria contained in the applicable authentication database to be success-
fully authenticated. Authentication ends with a FAIL response. An ERROR means that the
security server has not responded to an authentication query. Because of this, no authentication
1439_CCNP_3.book Page 623 Monday, November 15, 2004 10:35 AM

Authentication, Authorization, and Accounting (AAA) 623

has been attempted. Only when an ERROR is detected does AAA select the next authentica-
tion method defined in the authentication method list.
One of the advantages of AAA is that more than one of these methods can be configured, and
they are tried in sequence. For example, the router can be configured to authenticate PPP
users by first consulting a group of RADIUS or TACACS+ servers. If the router is unable to
connect to a server, a backup method, such as using the local username/password database,
can be configured.
Using AAA, you can configure up to four methods in a method list, as illustrated in Figure 9-32.
If all the defined methods return an error, the user is not authenticated.

Figure 9-32 Use the aaa authentication Command to Specify the Authentication Type, Method List
Type, and Authorization Methods

1 2 3
Authentication Method1,
Type List Type Method1 Method2…
login default login local
enable named list enable enable
ppp line line
arap group tacacs+ group tacacs+
nasi group radius group radius
kerberos kerberos

Router (config) #aaa authentication type {default} | list-


name}method1{…[method4] }

AAA commands can be confusing because there are so many syntax possibilities. When con-
figuring AAA authentication, as illustrated in Figure 9-32, it is best to follow a three-step pro-
cess for each aaa authentication command:
Step 1 Specify the authentication type (login, enable, PPP, and so on).
Step 2 Specify the method list as default or give it a name.
Step 3 List the authentication methods to be tried in order.
For example, the syntax for creating a method list to be used for PPP authentication is
aaa authentication ppp {default | list-name} method1 [...[method4]]

The aaa authentication login command enables AAA authentication for logins on terminal
lines (ttys), virtual terminal lines (vtys), and the console (con 0). To create one or more lists
that are tried at login, use the following command:
aaa authentication login {default | list-name} method1 [...[method4]]
1439_CCNP_3.book Page 624 Monday, November 15, 2004 10:35 AM

624 Chapter 9: Monitoring and Security

The default list is applied to all lines. If a named list is configured, apply it to a specific line or
group of lines using the aaa authentication login command.
The additional methods of authentication are used only if the previous method returns an
ERROR, not a FAIL.
A typical ERROR is a failure to connect with a member of a server group because of link fail-
ure or a server-side problem.
To ensure that the user is granted access, even if all methods return an ERROR, specify none
as the final method in the command line. If all defined methods end with an ERROR and
none is not specified as the final method, the user is not authenticated. If authentication is not
specifically set for a line, the default is to deny access, and no authentication is performed.
Depending on the network security policy, none may be configured as the final method.
Alternatively, the security policy might dictate that denying access when all other methods
return an ERROR is the most secure course of action.
Because this authentication method list specifies TACACS+ as the first method, the tacacs-
server host and tacacs-server key commands are used to configure RTA as a TACACS+
client.
The aaa new-model command enables the AAA feature. Finally, the aaa authentication
login command defines the method list. The method list configures RTA to attempt to contact
the TACACS+ servers first. If neither server is reached, this method returns an ERROR and
AAA tries to use the second method, the enable password. If this attempt also returns an
ERROR (because no enable password is configured on the router), the user is allowed access
with no authentication.
The default list is applied to the console (con 0), all tty lines (including the auxiliary line or
AUX port), and all vty lines. The default method list can be overridden by a named list to one
or more of these lines. Example 9-18 shows how to configure a named list for the network
shown in Figure 9-33.
RTA is configured with the radius-server host and radius-server key commands, because
the named method list relies on RADIUS. The aaa authentication login default local com-
mand configures the default method as the local username/password database. This method is
applied to all ttys, vtys, and the console by default.
The aaa authentication login PASSPORT group radius local none command creates a
named method list called PASSPORT. The first method in this list is the group of RADIUS
servers. In the event that RTA cannot contact any RADIUS server, the local username/pass-
word database is tried. The none keyword ensures that, if no usernames exist in the local
database, the user is granted access.
1439_CCNP_3.book Page 625 Monday, November 15, 2004 10:35 AM

Authentication, Authorization, and Accounting (AAA) 625

Figure 9-33 A Named List Can Be Used to Authenticate with a RADIUS Server

E0 192.168.0.1

Public
Network RTA

UNIX Host
Running
RADIUS
192.168.1.23

Windows NT Host
Running RADIUS
192.168.0.22

Example 9-18 Configuring a Named List to Authenticate with a RADIUS Server

RTA(config)#radius-server host 192.168.0.22


RTA(config)#radius-server host 192.168.1.23
RTA(config)#radius-server key top secret
RTA(config)#aaa new-model
RTA(config)#aaa authentication login default local
RTA(config)#aaa authentication login PASSPORT group radius local none

Apply named method lists for login authentication by using the line login authentication
command login authentication listname.
To apply the PASSPORT method list to all five vty lines for the network shown in Figure 9-33,
you would enter the following commands:
RTA(config)#line vty 0 4
RTA(config-line)#login authentication PASSPORT

Configuring AAA Authorization


AAA authorization enables service limits available to a user. When AAA authorization is
enabled, the router uses information retrieved from the user’s profile, which is located either
in the local user database or on the security server, to configure the user’s session. After this is
done, the user is granted access to a requested service only if the information in the user pro-
file allows it.
1439_CCNP_3.book Page 626 Monday, November 15, 2004 10:35 AM

626 Chapter 9: Monitoring and Security

Cisco IOS Release 12.05T supports eight different options of authorization on a 2600 router:
■ Authentication proxy services—Applies specific security policies on a per-user basis.
■ Commands—Applies to the EXEC mode commands a user issues. To enable authori-
zation for specific, individual EXEC commands associated with a specific privilege
level, use the command keyword. This allows you to authorize all commands associ-
ated with a specified command level from 0 to 15.
■ Configuration commands—Using no aaa authorization configuration commands
stops the network access server from attempting configuration command authorization.
■ EXEC—Applies to the attributes associated with a user EXEC terminal session.
■ Network services—Applies to network connections. This can include a PPP, Serial
Line Internet Protocol (SLIP), or AppleTalk Remote Access Protocol (ARAP)
connection.
■ Reverse Telnet access—Applies to reverse Telnet sessions.
■ Configuration—Applies to downloading configurations from the AAA server.
■ IP mobile—Applies to authorization for IP mobile services.
AAA authorization is configured with the aaa authorization command. You must specify the
type of authorization when using this command. Table 9-22 lists and describes some of the
keywords used with the aaa authorization command.

Table 9-22 A Number of Options Are Available for Defining Authorization to Switch Commands
and Services

Keyword Description

auth-proxy Configures authorization for authentication proxy services.

commands Configures authorization for EXEC commands.


config-commands Configures authorization for configuration mode commands.

exec Configures authorization for starting an EXEC session.

ipmobile Configures authorization for Mobile IP services.

network Configures authorization for network services.

reverse-access Configures authorization for reverse Telnet connections.

As soon as an authorization type has been specified, define either a default method list or a
named method list. Named method lists must be applied to a specific interface before any of
the defined authorization methods are performed. The default method list is automatically
applied to all lines and interfaces if no other method list is defined.
1439_CCNP_3.book Page 627 Monday, November 15, 2004 10:35 AM

Authentication, Authorization, and Accounting (AAA) 627

Table 9-23 lists the authorization methods and their IOS keywords.

Table 9-23 Authorization Methods Are Specified as Arguments to the aaa authorization Command

Keyword Description

group tacacs+ TACACS+ authorization defines specific rights for users by associat-
ing attribute-value pairs, which are stored in a database on the
TACACS+ security server, with the appropriate user.

group radius RADIUS authorization defines specific rights for users by associating
attributes, which are stored in a database on the RADIUS server, with
the appropriate user.

if-authenticated The user is allowed to access the requested function provided that he
or she has been authenticated successfully.
none The router does not request authorization information; authorization
is not performed over this line/interface.

local The router consults its local database, as defined by the username
command, for example, to authorize specific rights for users. Only a
limited set of functions can be controlled via the local database.

Before configuring AAA authorization, perform the following tasks:


Step 1 Enable AAA using the aaa new-model command.
Step 2 Configure AAA authentication. Authorization generally takes place after
authentication and relies on authentication to work properly.
Step 3 Configure the router as a TACACS+ or RADIUS client if necessary.
Step 4 Configure the local username/password database if necessary. Using the user-
name command, rights associated with specific users can be defined.
After TACACS+ and authentication are configured, configure authorization using the follow-
ing global configuration command:
aaa authorization type {default | list-name} [method1 [...[method4]]

Figure 9-34 shows AAA authorization configuration.


The highlighted command shown in Example 9-19 configures authorization for reverse Telnet
sessions for the network shown in Figure 9-35.
1439_CCNP_3.book Page 628 Monday, November 15, 2004 10:35 AM

628 Chapter 9: Monitoring and Security

Figure 9-34 Use the aaa authorization Command to Specify the Authorization Type, Method List
Type, and Authorization Methods

1 2 3
Authentication Method1
Type List Type Method1 Method2…
auth-proxy default group tacacs+ group tacacs+
commands named list group radius group radius
config-commands if-authenticated if-authenticated
exec none none
ip-mobile local local
network
reverse-access

Example 9-19 Configuring Authorization for Reverse Telnet Sessions

RTA(config)#tacacs-server host 192.168.0.11 255.255.255.0


RTA(config)#tacacs-server host 192.168.1.23 255.255.255.0
RTA(config)#tacacs-server key topsecret
RTA(config)#aaa new-model
RTA(config)#aaa authentication login default group tacacs+ enable none
RTA(config)#aaa authorization reverse-access default group tacacs+

Figure 9-35 Authorization Can Even Be Configured for Reverse Telnet Sessions

e0 192.168.0.1
UNIX Host
Public Running
Network RTA TACACS+
192.168.1.23/24

UNIX Host
Running TACACS+
192.168.0.11/24

Users attempting to reverse Telnet from the router must be authorized to issue the command
first by a TACACS+ server.
1439_CCNP_3.book Page 629 Monday, November 15, 2004 10:35 AM

Authentication, Authorization, and Accounting (AAA) 629

Example 9-20 presents a sample EXEC authorization configuration for the network shown in
Figure 9-35. When configured with the highlighted command, the router contacts a TACACS+
server to determine if users are permitted to start an EXEC shell when they log in.

Example 9-20 The Ability to Start an EXEC Shell Can Be Restricted Using AAA Authorization

RTA(config)#tacacs-server host 192.168.0.11 /24


RTA(config)#tacacs-server host 192.168.1.23 /24
RTA(config)#tacacs-server key topsecret
RTA(config)#aaa new-model
RTA(config)#aaa authentication login default group tacacs+ enable none
RTA(config)#aaa authorization exec default group tacacs+ local

The aaa authorization command is used to control exactly which commands a user is
allowed to enter on the router. Users can enter commands only at or beneath their privilege
level. All IOS router commands are assigned a privilege level from 0 to 15. By default, the
router has three privilege levels:
■ privilege level 1—Nonprivileged (the prompt is router>), the default level for login.
■ privilege level 15—Privileged (the prompt is router#), the level after going into enable
mode.
■ privilege level 0—Includes five commands: disable, enable, exit, help, and logout.
When a user logs in to the router EXEC via the console or a vty line, he or she can issue any
command in privilege level 1 and/or privilege level 0 by default. After the user authenticates
using the enable command and enable password, he or she has privilege level 15.
Levels 2 to 14 are not used in a default configuration, but commands that are normally at level
15 can be moved down to one of those levels, and commands that are normally at level 1 can
be moved up to one of those levels. Obviously, this security model involves some administra-
tion on the router. To determine the privilege level as a logged-in user, use the show privilege
command.
To determine what commands are available at a particular privilege level for the Cisco IOS
software release being used, enter a ? at the command line when logged in at that privilege
level.
Instead of assigning privilege levels, command authorization can be done if the authentica-
tion server supports TACACS+. The RADIUS protocol does not support command
authorization.
Which commands belong to which privilege levels can be precisely configured, including
manually defined levels. The commands shown in Example 9-21 move the snmp-server
1439_CCNP_3.book Page 630 Monday, November 15, 2004 10:35 AM

630 Chapter 9: Monitoring and Security

commands from privilege level 15 (the default) to privilege level 7. The ping command is
moved up from privilege level 1 to privilege level 7.

Example 9-21 Commands Can Be Moved to a Lower Privilege Level

RTA(config)#privilege configure level 7 snmp-server host


RTA(config)#privilege configure level 7 snmp-server enable
RTA(config)#privilege configure level 7 snmp-server
RTA(config)#privilege exec level 7 ping
RTA(config)#privilege exec level 7 configure terminal
RTA(config)#privilege exec level 7 configure

Use the aaa authorization command to grant access to commands by privilege level, as dem-
onstrated in Example 9-22.

Example 9-22 Access to Different Commands as a Function of Privilege Level Can Be Affected by Using the aaa
authorization Command

RTB(config)#aaa authorization commands 0 default group tacacs+ local


RTB(config)#aaa authorization commands 15 default group tacacs+ local
RTB(config)#aaa authorization commands 7 default group tacacs+ local

The user who logs in with level 7 privileges can ping and do snmp-server configuration in
configuration mode. Other configuration commands are unavailable.
A user’s privilege level can be determined by the security server or the local username/pass-
word database. To configure a local user for a specific privilege, use the following global con-
figuration command:
username name privilege level password password

For example, the command used to create a user named flannery with a privilege level of 7 is
username flannery privilege 7 password letmein

When this user logs in, she has access only to commands in privilege level 7 and below.

Configuring AAA Accounting


Like authentication and authorization method lists, method lists for accounting define how
accounting is performed and the sequence in which these methods are performed.
Named accounting method lists are used to designate a particular security protocol to be used
on specific lines or interfaces for accounting services. The default method list is automati-
cally applied to all interfaces except those that have a named method list explicitly defined.
1439_CCNP_3.book Page 631 Monday, November 15, 2004 10:35 AM

Authentication, Authorization, and Accounting (AAA) 631

As with AAA authentication and authorization, a defined method list overrides the default
method list.
Accounting method lists are specific to the type of accounting being requested. AAA sup-
ports six different types of accounting:
■ Network—Provides information for all PPP, SLIP, or ARAP sessions, including packet
and byte counts.
■ EXEC—Provides information about user EXEC terminal sessions of the network
access server.
■ Commands—Provides information about the EXEC mode commands that a user
issues. Command accounting generates accounting records for all EXEC mode com-
mands, including global configuration commands, associated with a specific privilege
level.
■ Connection—Provides information about all outbound connections made from the net-
work access server, such as Telnet, local-area transport (LAT), TN3270, packet assem-
bler/disassembler (PAD), and rlogin.
■ System—Provides information about system-level events.
■ Resource—Provides “start” and “stop” records for calls that have passed user authenti-
cation, and provides “stop” records for calls that fail to authenticate.
To configure AAA accounting, issue the aaa accounting command. When using this com-
mand, specify which type of accounting to configure. Table 9-24 lists some of the keywords
associated with the aaa accounting command.

Table 9-24 A Number of Options Are Available to Account for Switch Commands, Connections,
and Services

Keyword Description

commands Configures AAA accounting for EXEC commands.

connection Configures AAA accounting for outbound connections, such as Telnet and
rlogin.

exec Configures AAA accounting for starting an EXEC session.

nested Configures AAA accounting to generate NETWORK records before the


EXEC-STOP records. This keyword formats accounting logs so that start
and stop events are kept together, which might be useful for billing
purposes.

network Configures AAA accounting for networking services.


continues
1439_CCNP_3.book Page 632 Monday, November 15, 2004 10:35 AM

632 Chapter 9: Monitoring and Security

Table 9-24 A Number of Options Are Available to Account for Switch Commands, Connections,
and Services (Continued)

Keyword Description

suppress Configures AAA accounting to not generate accounting records for a spe-
cific type of user.

system Configures AAA accounting for systems events.

update Enables periodic interim accounting records to be sent to the accounting


server.

NOTE After an accounting type has been specified, define either a default method list or a named
Note that the system method list. Named method lists must be applied to a specific interface before any of the
option of AAA
defined authorization methods are performed. The default method list is automatically
accounting does not
support named method applied to all lines and interfaces if no other method list is defined.
lists.
After specifying a named or default list, indicate the accounting record type using one of the
following four keywords, one for each accounting record type:
■ none—To stop all accounting activities on this line or interface, use the none keyword.
■ start-stop—For more accounting information, use the start-stop keyword to send a
start accounting notice at the beginning of the requested event and a stop accounting
notice at the end of the event.
■ stop-only—For minimal accounting, use the stop-only keyword, which instructs the
specified method (RADIUS or TACACS+) to send a stop record accounting notice at
the end of the requested user process.
■ wait-start—As in start-stop, wait-start sends both a start and a stop accounting
record to the accounting server. However, if the wait-start keyword is used, the
requested user service does not begin until the start accounting record is acknowledged.
A stop accounting record is also sent.
Finally, after specifying the accounting type and the accounting record type, configure the
accounting method using the following command:
Router(config)aaa accounting type {{default} | list-name} record-type
method1 [...[method4]]}
1439_CCNP_3.book Page 633 Monday, November 15, 2004 10:35 AM

Authentication, Authorization, and Accounting (AAA) 633

Figure 9-36 shows the AAA accounting configuration.

Figure 9-36 Use the aaa accounting Command to Specify the Accounting Type, Method List Type,
Record Type, and Accounting Methods

1 2 2 3
Authentication Method2
Type List Type Record Type Method1 Method3…
commands default none group tacacs+ group tacacs+
connection named list start-stop group radius group radius
exec stop-only
nested wait-start
network
suppress
system
update

Before configuring AAA accounting, perform the following tasks:


Step 1 Enable AAA using the aaa new-model command.
Step 2 Configure the router as a TACACS+ or RADIUS client. This is required for
AAA accounting. A server is needed to act as a repository for the accounting
data.
Example 9-23 shows a possible AAA accounting configuration for the network shown in
Figure 9-37.

Example 9-23 Configuring AAA Accounting

RTA(config)#tacacs-server host 192.168.0.11 255.255.255.0


RTA(config)#tacacs-server host 192.168.1.23 255.255.255.0
RTA(config)#tacacs-server key topsecret
RTA(config)#aaa new-model
RTA(config)#aaa authentication login default group tacacs+ local enable
RTA(config)#aaa accounting network default start-stop group tacacs+

The aaa accounting network command enables accounting for network services, which
includes information for all PPP, SLIP, and ARAP sessions, including packet and byte counts.
1439_CCNP_3.book Page 634 Monday, November 15, 2004 10:35 AM

634 Chapter 9: Monitoring and Security

Figure 9-37 Accounting Can Be Configured for Network Services, Such as PPP

e0 192.168.0.1
UNIX Host
Public Running
Network RTA TACACS+
192.168.1.23/24

UNIX Host
Running TACACS+
192.168.0.11/24

As shown in Example 9-23, RTA sends accounting information for PPP sessions to a
TACACS+ server. The format of the output stored on the server varies, depending on the
TACACS+ or RADIUS implementation. Example 9-24 presents sample TACACS+ output
from a UNIX TACACS+ daemon.

Example 9-24 Accounting Is Typically Logged on a TACACS+ or RADIUS Server

Wed Jun 27 04:02:19 2001 172.16.25.15 fgeorge Async5


562/4327528 starttask_id=35
service=ppp
Wed Jun 27 04:02:25 2001 172.16.25.15 fgeorge Async5
562/4327528 update_task_id=35 service+ppp protocol=ip
addr=10.1.1.2
Wed Jun 27 04:05:03 2001 172.16.25.15 fgeorge Async5
562/4327528 stoptask_id=35 service=ppp protocol=ip
addr=10.1.1.2 bytes_in=3366 bytes_out=2149 paks_in=42
packs_out=28 elapsed_time=164

IEEE 802.1x Port-Based Authentication


The IEEE 802.1x standard defines a client/server-based access control and authentication
protocol that restricts unauthorized clients from connecting to a LAN through publicly acces-
sible ports. The authentication server authenticates each client connected to a switch port
before making available any services offered by the switch or LAN.
1439_CCNP_3.book Page 635 Monday, November 15, 2004 10:35 AM

IEEE 802.1x Port-Based Authentication 635

Until the client is authenticated, 802.1x access control allows only Extensible Authentication
Protocol over LAN (EAPOL) traffic through the port to which the client is connected. After
authentication is successful, normal traffic can pass through the port.
With 802.1x port-based authentication, the devices in the network have specific roles.
A client is the device (workstation) that requests access to the LAN and switch services and
responds to requests from the switch. The workstation must be running 802.1x-compliant client
software, such as that offered in the Microsoft Windows XP operating system. (The client is
the supplicant in the IEEE 802.1x specification.)
The authentication server performs the actual authentication of the client. The authentication
server validates the client’s identity and tells the switch whether the client is authorized to
access the LAN and switch services. Because the switch acts as the proxy, the authentication
service is transparent to the client. In this release, the RADIUS security system with EAP
extensions is the only supported authentication server; it is available in Cisco Secure Access
Control Server version 3.0. RADIUS operates in a client/server model in which secure
authentication information is exchanged between the RADIUS server and one or more
RADIUS clients.
A switch (edge switch or wireless access point) controls the physical access to the network
based on the client’s authentication status. The switch acts as an intermediary (proxy)
between the client and the authentication server, requesting identity information from the
client, verifying that information with the authentication server, and relaying a response to
the client. The switch includes the RADIUS client, which is responsible for encapsulating
and decapsulating the EAP frames and interacting with the authentication server.
When the switch receives EAPOL frames and relays them to the authentication server, the
Ethernet header is stripped and the remaining EAP frame is re-encapsulated in the RADIUS
format. The EAP frames are not modified or examined during encapsulation, and the authen-
tication server must support EAP within the native frame format. When the switch receives
frames from the authentication server, the server’s frame header is removed, leaving the EAP
frame, which is then encapsulated for Ethernet and sent to the client.
The devices that can act as intermediaries include the Catalyst 3550 multilayer switch, the
Catalyst 2950 switch, or a wireless access point. These devices must be running software that
supports the RADIUS client and 802.1x.

Authentication Initiation and Message Exchange


The switch or the client can initiate authentication. If authentication is enabled on a port by
using the dot1x port-control auto interface configuration command, the switch must initiate
authentication when it determines that the port link state transitions from down to up. The
1439_CCNP_3.book Page 636 Monday, November 15, 2004 10:35 AM

636 Chapter 9: Monitoring and Security

switch then sends an EAP-request/identity frame to the client to request its identity. (Typi-
cally, the switch sends an initial identity/request frame followed by one or more requests for
authentication information.) Upon receipt of the frame, the client responds with an EAP-
response/identity frame.
However, if during bootup the client does not receive an EAP-request/identity frame from the
switch, the client can initiate authentication by sending an EAPOL-start frame. This prompts
the switch to request the client’s identity.
If 802.1x is not enabled or supported on the network access device, any EAPOL frames from
the client are dropped. If the client does not receive an EAP-request/identity frame after a
defined number of attempts to start authentication, the client sends frames as if the port were
in the authorized state. A port in the authorized state effectively means that the client has been
successfully authenticated.
When the client supplies its identity, the switch begins its role as the intermediary, passing
EAP frames between the client and the authentication server until authentication succeeds or
fails. If the authentication succeeds, the switch port becomes authorized.
The specific exchange of EAP frames depends on the authentication method being used. Fig-
ure 9-38 shows a message exchange initiated by the client using the One-Time Password
(OTP) authentication method with a RADIUS server.

Figure 9-38 Authentication Initiation and Message Exchange Are Used with the One-Time
Password Authentication Method with a RADIUS Server

Authentication
Server
Client (RADIUS)
Catalyst 2950 or Catalyst 3550 Switch

EAPOL-Start
EAP-Request/Identity
EAP-Response/Identity RADIUS Access-Request
EAP-Request/OTP RADIUS Access-Challenge
EAP-Response/OTP RADIUS Access-Request
EAP-Success RADIUS Access-Accept

Port Authorized

EAPOL-Logoff

Port Unauthorized
1439_CCNP_3.book Page 637 Monday, November 15, 2004 10:35 AM

IEEE 802.1x Port-Based Authentication 637

Ports in Authorized and Unauthorized States


The switch port state determines whether the client is granted access to the network. As
shown in Figure 9-39, the port starts in the unauthorized state. While in this state, the port dis-
allows all ingress and egress traffic except for 802.1x protocol packets. When a client is suc-
cessfully authenticated, the port transitions to the authorized state, allowing all traffic for the
client to flow normally.

Figure 9-39 IEEE 802.1x Port States Determine Whether the Client Is Granted Access to the
Network

Port Unauthorized

Client Machine Connects to Switch

802.1x Authentication Process

Port Authorized

Traffic Forwarded

Client Shuts Down/Disconnects

If a client that does not support 802.1x is connected to an unauthorized 802.1x port, the
switch requests the client’s identity. In this situation, the client does not respond to the
request, the port remains in the unauthorized state, and the client is not granted access to the
network.
In contrast, when an 802.1x-enabled client connects to a port that is not running the 802.1x
protocol, the client initiates the authentication process by sending the EAPOL-start frame.
When no response is received, the client sends the request for a fixed number of times.
Because no response is received, the client begins sending frames as if the port were in the
authorized state.
To control the port authorization state, use the dot1x port-control interface configuration
command. Several keywords are associated with this command.
With the force-authorized keyword, 802.1x authentication is disabled and the port transi-
tions to the authorized state without any authentication exchange required. The port sends
and receives normal traffic without 802.1x-based authentication of the client. This is the
default setting.
1439_CCNP_3.book Page 638 Monday, November 15, 2004 10:35 AM

638 Chapter 9: Monitoring and Security

The force-unauthorized keyword causes the port to remain in the unauthorized state, ignor-
ing all attempts by the client to authenticate. The switch cannot provide authentication ser-
vices to the client through the interface.
The auto keyword enables 802.1x authentication and causes the port to begin in the unautho-
rized state, allowing only EAPOL frames to be sent and received through the port. The
authentication process begins when the port’s link state transitions from down to up or when
an EAPOL-start frame is received. The switch requests the client’s identity and begins relay-
ing authentication messages between the client and the authentication server. Each client that
attempts to access the network presents its MAC address to the switch for unique identification.
If the client is successfully authenticated (if it receives an Accept frame from the authentica-
tion server), the port state changes to authorized, and all frames from the authenticated client
are allowed through the port. If the authentication fails, the port remains in the unauthorized
state, but authentication can be retried. If the authentication server cannot be reached, the
switch can resend the request. If no response is received from the server after the specified
number of attempts, authentication fails, and network access is not granted.
When a client logs off, it sends an EAPOL-logoff message, causing the switch port to transi-
tion to the unauthorized state.
If a port’s link state transitions from up to down, or if an EAPOL-logoff frame is received, the
port returns to the unauthorized state.

Supported Topologies
The 802.1x port-based authentication is supported in two topologies:
■ Point-to-point
■ Wireless LAN
In a point-to-point configuration, only one client can be connected to the 802.1x-enabled
switch port. The switch detects the client when the port link state changes to the up state.
If a client leaves or is replaced with another client, the switch changes the port link state to
down, and the port returns to the unauthorized state.
Figure 9-40 shows 802.1x port-based authentication in a wireless LAN. The 802.1x switch
port is configured as a multiple-host port that becomes authorized as soon as one client is
authenticated. When the port is authorized, all other hosts indirectly attached to it are granted
access to the network. If the port becomes unauthorized (if reauthentication fails or an
EAPOL-logoff message is received), the switch denies network access to all the attached
clients. In this topology, the wireless access point is responsible for authenticating the clients
attached to it, and the wireless access point acts as a client to the switch.
1439_CCNP_3.book Page 639 Monday, November 15, 2004 10:35 AM

IEEE 802.1x Port-Based Authentication 639

Figure 9-40 IEEE 802.1x Is Frequently Used as a Component of an Enterprise Wireless LAN
Security Policy

Authentication
Server
Catalyst 2950 (RADIUS)
or Catalyst 3550
Access Point (Switch)

Workstations (Clients)

802.1x Configuration Guidelines


When the 802.1x protocol is enabled, ports are authenticated before any other Layer 2 feature
is enabled.
The 802.1x protocol is supported on Layer 2 static-access ports, but it is not supported on the
following port types:
■ Trunk ports—Attempting to enable 802.1x on a trunk port generates an error message,
and 802.1x is not enabled. The port mode does not change if the mode of an 802.1x
enabled port is changed to trunk.
■ Dynamic ports—A port in dynamic mode can negotiate with its neighbor to become a
trunk port. Attempting to enable 802.1x on a dynamic port results in an error message,
and 802.1x is not enabled. The port mode does not change if the mode of an 802.1x-
enabled port is changed to dynamic.
■ VQP ports—Attempting to enable 802.1x on a dynamic-access (VLAN Query Proto-
col [VQP]) port generates an error message, and 802.1x is not enabled. Attempting to
change an 802.1x-enabled port to dynamic VLAN assignment generates an error mes-
sage, and the VLAN configuration is not changed.
■ Active EtherChannel ports—Before enabling 802.1x on the port, first remove the
port from the EtherChannel before enabling 802.1x on it. Attempting to enable 802.1x
on an EtherChannel or on an active port in an EtherChannel generates an error mes-
sage, and 802.1x is not enabled. A port does not join the EtherChannel if 802.1x is
enabled on a not-yet-active port of an EtherChannel.
■ Secure ports—A secure port cannot be configured as an 802.1x port. Attempting to
enable 802.1x on a secure port generates an error message, and 802.1x is not enabled.
Port security settings do not change if an 802.1x-enabled port is changed to a secure
port, and an error message is generated.
1439_CCNP_3.book Page 640 Monday, November 15, 2004 10:35 AM

640 Chapter 9: Monitoring and Security

■ SPAN destination ports—802.1x can be enabled on a port that is a SPAN destination


port. However, 802.1x is disabled until the port is removed as a SPAN destination.
802.1x can be enabled on a SPAN source port.

Configuring 802.1x Port-Based Authentication


To enable 802.1x port-based authentication, AAA must be enabled. An authentication method
list must also be specified. Recall that a method list describes the sequence and authentication
methods to be queried to authenticate a user.
Table 9-25 lists the default 802.1x configuration settings.

Table 9-25 The Default 802.1x Configuration Settings Include a 60-Minute Delay for Reauthentication
Attempts

Feature Default Setting

AAA authentication Disabled

RADIUS server
IP address None specified
UDP authentication port 1812
Key None specified

Per-interface 802.1x enable state Disabled (force-unauthorized). The port transmits and
receives normal traffic without 802.1x-based client
authentication.

Periodic reauthentication Disabled

Number of seconds between 3600 seconds


reauthentication attempts
Quiet period 60 seconds (how long the switch remains in the quiet
state following a failed authentication exchange with
the client)

Retransmission time 30 seconds (how long the switch should wait for a
response to an EAP request/identity frame from the
client before retransmitting the request)
1439_CCNP_3.book Page 641 Monday, November 15, 2004 10:35 AM

IEEE 802.1x Port-Based Authentication 641

Table 9-25 The Default 802.1x Configuration Settings Include a 60-Minute Delay for Reauthentication
Attempts (Continued)

Feature Default Setting

Maximum retransmission 2 times (the number of times the switch sends an EAP
number request/identify frame before restarting the authentica-
tion process)

Multiple host support Disabled

Client timeout period 30 seconds (when relaying a request from the authenti-
cation server to the client, how long the switch waits
for a response before retransmitting the request to the
client). This setting cannot be configured.

Authentication server timeout 30 seconds (when relaying a request from the client to
period the authentication server, how long the switch waits for
a reply before retransmitting the response to the
server). This setting cannot be configured.

The software uses the first method listed to authenticate users. If that method fails to respond,
the software selects the next authentication method in the method list. This process continues
until there is successful communication with a listed authentication method or until all defined
methods are exhausted. If authentication fails at any point in this cycle, the authentication
process stops, and no other authentication methods are attempted.
Beginning in privileged EXEC mode, follow the steps shown in Table 9-26 to configure
802.1x port-based authentication.

Table 9-26 AAA Must Be Configured Before 802.1x Is Enabled

Step Command Description

1 configure terminal Enters global configuration mode.

2 aaa new-model Enables AAA.


continues
1439_CCNP_3.book Page 642 Monday, November 15, 2004 10:35 AM

642 Chapter 9: Monitoring and Security

Table 9-26 AAA Must Be Configured Before 802.1x Is Enabled (Continued)

Step Command Description

3 aaa authentication dot1x {default} Creates an 802.1x authentication


method1 [method2...] method list. To create a default list that
is used when a named list is not speci-
fied in the authentication command,
use the default keyword followed by
the methods that are to be used in
default situations. The default method
list is automatically applied to all
interfaces.
Enter at least one of these keywords:
group radius—Uses the list of all
RADIUS servers for authentication.
none—Uses no authentication. The
client is automatically authenticated
without the switch using the informa-
tion supplied by the client.

4 interface interface-id Enters interface configuration mode and


specifies the interface to be enabled for
802.1x authentication.

5 dot1x port-control auto Enables 802.1x on the interface.

6 end Returns to privileged EXEC mode.

7 show dot1x Verifies your entries. Check the Status


column in the display’s 802.1x Port
Summary section. An enabled status
means that the port-control value is set
to either auto or force-authorized.

8 copy running-config startup-config (Optional) Saves your entries in the


configuration file.
1439_CCNP_3.book Page 643 Monday, November 15, 2004 10:35 AM

Summary 643

Summary
The requirement for monitoring and securing multilayered networks has increased with the
advent of data-rich technology, such as voice over IP and streaming multimedia. This chapter
covered discussing and implementing mechanisms for monitoring traffic and securing
switches in a multilayer switched network to improve the quality of service delivered by
the network.
The following traffic-monitoring technologies were discussed:
■ SPAN
■ VSPAN
■ RSPAN
■ Specialist traffic monitoring and control hardware
The following security-related technologies were discussed:
■ Access control policy
■ Basic security measures
■ Communications encryption
■ Securing remote management
■ Securing user access
■ Authentication, authorization, and accounting
■ Port security
■ Protected ports
■ 802.1x port-based authentication
1439_CCNP_3.book Page 644 Monday, November 15, 2004 10:35 AM

644 Chapter 9: Monitoring and Security

Key Terms
IEEE 802.1x A standard defining a client/server-based access control and authentication
protocol that restricts unauthorized clients from connecting to a LAN through publicly acces-
sible ports. The authentication server authenticates each client connected to a switch port
before making available any services offered by the switch or the LAN. Until the client is
authenticated, 802.1x access control allows only Extensible Authentication Protocol over
LAN (EAPOL) traffic through the port to which the client is connected. After authentication
is successful, normal traffic can pass through the port.
Kerberos A secret-key network authentication protocol used with AAA that uses the DES
cryptographic algorithm for encryption and authentication. Kerberos was designed to authen-
ticate requests for network resources. It is based on the concept of a trusted third party that
performs secure verification of users and services.
Network Analysis Module (NAM) A LAN monitoring solution that should be deployed at
LAN aggregation points where it can see critical traffic and virtual LANs (VLANs).
Port ACL ACLs can be applied to Layer 2 interfaces on a switch. Port ACLs are supported
on Layer 2 physical interfaces only, not on EtherChannel interfaces. Port ACLs are applied on
interfaces for inbound traffic only. They support standard IP access lists using source addresses,
extended IP access lists using source and destination addresses and optional protocol type
information, and MAC extended access lists using source and destination MAC addresses
and optional protocol type information.
RADIUS A client/server authentication and accounting protocol for use with access serv-
ers. RADIUS is specified in RFCs 2865, 2866, and 2868.
Remote Monitoring (RMON) A monitoring specification that lets various network moni-
tors and console systems exchange network-monitoring data. RMON gives network adminis-
trators more freedom in selecting network-monitoring probes and consoles with features that
meet their particular networking needs.
Router ACL An ACL that can be applied to SVIs, physical Layer 3 interfaces, and Layer 3
EtherChannel interfaces. Router ACLs are applied on interfaces for specific directions
(inbound or outbound). One IP access list in each direction can be specified.
RSPAN An implementation of SPAN designed to support source ports, source VLANs, and
destination ports across different switches. RSPAN allows remote monitoring of multiple
switches across a network.
Secure Shell (SSH) A program to log into another computer over a network, to execute
commands in a remote machine, and to move files from one machine to another. It provides
strong authentication and secure communications over insecure channels.
1439_CCNP_3.book Page 645 Monday, November 15, 2004 10:35 AM

Check Your Understanding 645

Switch Fabric Module (SFM) A line card that delivers an increase in available system
bandwidth on a Catalyst 6500 switch from the default 32 Gbps on the forwarding bus to
256 Gbps. Including an SFM in a Catalyst 6500 chassis increases the speed at which switch-
ing, routing, and network monitoring modules can transfer data between each other. The SFM
reduces latency and the incidence of packet drop caused by bandwidth bottlenecks at traffic
aggregation points within the network.
Switched Port Analyzer (SPAN) A tool used with Catalyst switches to enable the capture of
traffic. A SPAN session is an association of a destination port with a set of source ports, con-
figured with parameters that enable the monitoring of network traffic.
TACACS+ A Cisco-proprietary protocol used to authenticate users against a database.
TACACS+ uses TCP to communicate between a TACACS+ server and a TACACS+ client.
VLAN access control list (VACL) See VLAN map.
VLAN-based SPAN (VSPAN) An analysis of network traffic in one or more VLANs.
VLAN map Also called a VLAN ACL or VACL. Can filter all traffic traversing a switch.
VLAN maps can be configured on the switch to filter all packets that are routed into or out of
a VLAN or that are bridged within a VLAN. VLAN maps are used strictly for security packet
filtering. Unlike router ACLs, VLAN maps are not defined by direction (input or output).

Check Your Understanding


Use the following review questions to test your understanding of the concepts covered in this
chapter. Answers are listed in Appendix A, “Check Your Understanding Answer Key.”
1. Which of the following are valid SPAN source ports?

A. Layer 2 port

B. Layer 3 port

C. EtherChannel

D. Trunk port
2. An RSPAN session requires the use of what type of port(s)?

A. Source port

B. Destination port

C. Trunk port

D. Reflector port
1439_CCNP_3.book Page 646 Monday, November 15, 2004 10:35 AM

646 Chapter 9: Monitoring and Security

3. What Catalyst 6500 module is used to store and modify monitored traffic?

A. Intrusion Detection Sensor

B. Switch Fabric Module

C. Network Analysis Module

D. Supervisor Engine
4. What is the web interface used with the NAM called?

A. Netsys Baseliner

B. RMON 2 Viewer

C. RMON Viewer

D. NAM Traffic Analyzer


5. The Switch Fabric Module is used on which Catalyst switches?

A. 2950

B. 3550

C. 6500

D. 7600
6. Basic security measures include which considerations?

A. Physical security

B. Privilege level

C. Remote access

D. Password protection
7. The CoS is set to what value on traffic sourced by a Cisco IP Phone?

A. 0

B. 1

C. 5

D. 7
8. Out-of-band management is performed on what lines or interfaces?

A. Ethernet

B. Console

C. Auxiliary

D. vty
1439_CCNP_3.book Page 647 Monday, November 15, 2004 10:35 AM

Check Your Understanding 647

9. Secure Shell requires the use of what command(s)?

A. ip domain-name

B. crypto key generate rsa

C. ssh

D. login local
10. What type of access list filters both routed and bridged traffic?

A. MAC ACL

B. Port ACL

C. VLAN map

D. Router ACL
1439_CCNP_3.book Page 648 Monday, November 1, 2004 11:16 AM

Objectives
After completing this chapter, you will be able to perform tasks related to the following:
■ Identify the characteristics of an Ethernet service
■ Describe the transparent local area network (LAN) services architecture
■ Compare the benefits of transparent LAN service over legacy services
■ Describe Cisco transparent LAN service solutions
■ Describe transparent LAN service implementations
1439_CCNP_3.book Page 649 Wednesday, October 27, 2004 9:54 AM

Chapter 10

Transparent LAN Services


This chapter introduces the characteristics of transparent LAN architectures and services in a
metropolitan-area network (MAN). This chapter examines how transparent LAN services (TLS)
enhance the services previously provided by existing technologies and describes the Cisco
solutions.

Ethernet Solutions for Transparent LAN Services (TLS)


Cisco is committed to supporting the latest technologies in metropolitan optical networking,
including TLS, dense wavelength division multiplexing (DWDM), course wavelength division
multiplexing (CWDM), metro (Gigabit and 10 Gigabit) Ethernet, and Synchronous Optical
Network (SONET)/Synchronous Digital Hierarchy (SDH) deployments. Several Cisco products
are used to implement these technologies and services; in particular, the Optical Networking System
(ONS) and the Carrier Routing System (CRS) product lines supports these diverse technologies.
VLAN tunneling is useful for extending and differentiating campus VLANs in a metro optical
environment. This section introduces VLAN tunneling and contains an overview of the architec-
ture used for metro optical networking, including points of presence (POPs) and the SONET/
SDH/DWDM interconnections.

Same Network, New Services


Customers today have moved beyond the need for basic point-to-point Internet circuits and legacy
voice lines connecting private branch exchanges (PBXs). With the steadily growing acceptance
of voice over IP (VoIP) systems, increased demand for virtual private networks (VPNs), and
expanding distributed mesh networking, as with mobile wireless, new systems have to be in
place to support these infrastructures.
Transparent LAN Services (TLS) let the service provider offer the customer native LAN ser-
vices over wide-area links without the need to implement complicated and costly Asynchronous
Transfer Mode (ATM) networks. Figure 10-1 shows a TLS solution connecting gigabit service
1439_CCNP_3.book Page 650 Wednesday, October 27, 2004 9:54 AM

650 Chapter 10: Transparent LAN Services

through a SONET/DWDM infrastructure. The same optical infrastructure is being used to


carry IP over Gigabit Ethernet services, a feature that lets the service provider increase its
offering over a common infrastructure. TLS can be incorporated into existing optical infra-
structures.

Figure 10-1 Transparent LAN Services Include a Solution Connecting Gigabit Service Through a
SONET/DWDM Infrastructure

POP POP

ONS ONS
M M
15454 15454

PL PL

Gigabit Gigabit
Ethernet SONET SONET Ethernet
DWDM
New Same Core and Metro New
Services Network Services

The Cisco ONS 15327 (see Figure 10-2) and Cisco ONS 15454 platforms (see Figure 10-3)
support TLS today through the addition of Ethernet service cards. This support enables the
migration or addition of TLS service offerings by service providers to existing optical net-
work infrastructures without the need for costly equipment replacement. Through the addi-
tion of a single card, service providers can now offer additional TLS services to their clients.

Figure 10-2 The Cisco ONS 15327 Platform


1439_CCNP_3.book Page 651 Wednesday, October 27, 2004 9:54 AM

Ethernet Solutions for Transparent LAN Services (TLS) 651

Figure 10-3 The Cisco ONS 15454 Platform

The following sections explore these concepts:


■ VLAN tunneling
■ Intermetro LAN transport
■ Interservice point of presence (POP) connectivity
■ Metro segmentation
These topics are all discussed in the context of TLS.

VLAN Tunneling
VLAN tunneling in the metro environment allows customers to extend their logical network
topology across wide geographic areas. This comes into play especially when VoIP technolo-
gies are implemented. Without VLAN tunneling, customers are forced to renumber their
existing VLANs, or the service provider is forced to provide some sort of VLAN translation
at the access point to support multiple customers with overlapping VLAN numbers.
However, through DWDM and separate wavelength routing solutions, each customer is com-
pletely segmented from the others, allowing complete autonomy.
Figure 10-4 illustrates VLAN service for Customers A and B. VLAN tunneling allows the
service provider to support overlapping VLAN numbers on the same physical port, as shown
in Table 10-1.
1439_CCNP_3.book Page 652 Wednesday, October 27, 2004 9:54 AM

652 Chapter 10: Transparent LAN Services

Figure 10-4 VLAN Tunneling Permits Intra-VLAN Communication Over a MAN

Metro Customer A
VLANs 1, 5
POP

Customer A
(OC-192/DW/DM)
VLANs 1, 2, 3, 4, 5

Customer A
VLANs 1, 2, 4, 5

(OC-48/DW/DM) (OC-48)

Customer B ONS ONS Customer B


VLANs 1, 2, 3 15454 15327 VLANs 1, 2, 3

Table 10-1 VLAN Tunneling Allows the Service Provider to Support Overlapping VLAN Numbers
on the Same Physical Port

Customer VLANs

A 1, 2, 3, 4, 5

B 1, 2, 3

VLAN tunneling supports the isolation of Customer A’s VLANs 1, 2, and 3 from Customer
B’s VLANs 1, 2, and 3 over the same physical optical interface. Therefore, support is pro-
vided for VLANs 1, 2, 3, 4, and 5 for Customer A and VLANs 1, 2, and 3 for Customer B
over the same fiber.

Intermetro LAN Transport


As applications evolve, bandwidth needs increase. This increases the need for customer band-
width across the wide area as well as internally. TLS allows the service provider to offer high-
speed wide-area connectivity in a native LAN technology that the customer understands and
already supports.
1439_CCNP_3.book Page 653 Wednesday, October 27, 2004 9:54 AM

Ethernet Solutions for Transparent LAN Services (TLS) 653

Speeds up to OC-192 can provide wire-speed gigabit connectivity (see the upcoming section
“Defining SONET and SDH”). Gigabit Ethernet and 10 Gigabit Ethernet (10 GbE) over opti-
cal connections between two enterprise locations are now quite common (see Figure 10-5).

Figure 10-5 10 GbE Transports Over Optical Connections Are Becoming More Common in Inter-
metro Networks

(OC-12/48
192/DWDM) Metro Metro (OC-12/48)
Enterprise POP POP Enterprise

ONS ONS
15454 15454

Interservice POP Connectivity


As multiple service providers team up to offer extended service offerings to their customers,
the need for better interconnectivity increases also, as illustrated in Figure 10-6. TLS allows
for high-speed interconnections in an easy-to-support technology, as well as providing point-
to-multipoint connectivity.

Figure 10-6 Service Providers Can Work Together to Improve Interconnectivity with TLS and Better
Service Customers

POP POP

ISP A SP 2

ONS ONS
M M
115454 15327

PL PL

SP 1 ISP B

Gigabit Gigabit
Ethernet SONET DWDM SONET Ethernet
or TDM or TDM
1439_CCNP_3.book Page 654 Wednesday, October 27, 2004 9:54 AM

654 Chapter 10: Transparent LAN Services

The benefits provided by TLS allow for the seamless interconnectivity of multiple service
providers, which in turn allows for increased service offerings and support to the end customer.
Again, TLS enables the use of Gigabit Ethernet as a shared LAN in a metro optical environ-
ment. In Figure 10-6, ISPA and ISPB, along with service providers SP1 and SP2, can mutually
share content as a result of Gigabit Ethernet over optical usage.

Metro Segmentation
Transparent LAN services integrate into a full metro-segmentation network architecture, as
shown in Figure 10-7. The metro network is segmented into three areas:
■ Customer premises equipment (CPE)
■ Aggregation point for forwarding
■ POP, used to interconnect to other networks, such as the core of other metro networks

Figure 10-7 TLS Services Integrate into a Full Metropolitan-Area Network Architecture

15454 CPE

15454

Aggregation

POP 15454
7600 OSR

15454 Metro Core DWDM


GigE Connections

15454 15454

TLS provides for an economical, scalable, and established technology for connecting cus-
tomers who require extended wide-area bandwidth. In addition, with its native quality of ser-
vice (QoS) and VLAN support, customers have the advantage of advanced traffic shaping and
flexibility in logical network design.
TLS can provide CPE user VLANs with QoS at gigabit speeds. At the aggregation point, TLS
can provide a method to create shared multipoint connectivity that feeds into the POP. At the
1439_CCNP_3.book Page 655 Wednesday, October 27, 2004 9:54 AM

Introducing Transparent LAN Services Architecture 655

POP, TLS can provide an access point for content networking, as well as an interconnecting
point to transfer VLAN tunnels to the core network.
The benefits of integrating transparent LAN services into a full metro segmentation network
architecture can be summarized as follows:
■ Multiple service options:
— Dedicated point-to-point Ethernet
— Shared distributed multipoint Ethernet
— Internet-scaled tiered bandwidth sharing
■ One platform:
— Access wavelength redundancy
— Core route redundancy
— Full-method Gigabit Ethernet data backbone
■ Economical and scalable:
— Pack wavelengths and bits
— VLAN and Multiprotocol Label Switching (MPLS) VPN-enabled

Introducing Transparent LAN Services Architecture


The TLS architecture encompasses a wide range of services. Metro Ethernet services, such as
Gigabit or 10 GbE Internet access and high-speed virtual private network (VPN) access, are
available. IP+Optical is an emerging technology that provides high-speed man without rely-
ing on SONET/SDH or ATM. Point-to-point and multipoint Transparent LAN Services
(TLS) circuits are options for providing bandwidth to the customer. The multipoint option has
a greater reliance on QoS to provide guaranteed bandwidth to the customer.

Metro Ethernet Services


Understanding TLS architecture helps to facilitate network design and installation, as well as
long-term operations and support. It is important to understand where TLS fits into an overall
optical network architecture, as illustrated in Figure 10-8.
TLS is an ideal solution for providing shared bandwidth across a wide area, such as a distrib-
uted campus design, or for providing high bandwidth, where a LAN-based technology would
facilitate operations. Typically, TLS falls within the metro-to-customer access role.
1439_CCNP_3.book Page 656 Wednesday, October 27, 2004 9:54 AM

656 Chapter 10: Transparent LAN Services

Figure 10-8 TLS Fits into an Overall Optical Network Architecture

Dedicated STS
Circuit Shared STS
or Dedicated Circuit
Lambda or Shared Lambda

Four services can be offered by a metro Ethernet service provider:


■ High-speed Internet access—Gigabit Ethernet to the POP for Internet access
■ High-speed VPN access—Gigabit Ethernet connected into an MPLS backbone using
a local MPLS provider edge router
■ Transparent LAN services—Gigabit connectivity over a shared multipoint
metro LAN
■ Point-to-point LAN services—Gigabit point-to-point connectivity
The following section covers how TLS can be used in existing SONET-based networks and
natively with the optical layer. The following sections elaborate on TLS in the metro environ-
ment in terms of
■ IP+Optical efficiency
■ Point-to-point dedicated
■ Point-to-multipoint shared
■ QoS

IP+Optical
IP+Optical removes the need to layer SONET or ATM technologies between the Layer 3 pro-
tocol and the optical physical layer, as shown in Figure 10-9. Removing this additional tech-
nology greatly increases overhead efficiency.
The Layer 3 protocol is required to provide end-to-end error checking and recovery, as well
as any QoS. However, these functions are already built into the IP protocol.
1439_CCNP_3.book Page 657 Wednesday, October 27, 2004 9:54 AM

Introducing Transparent LAN Services Architecture 657

Figure 10-9 IP+Optical Removes the Need to Layer Technologies Between Layer 3 and Layer 1

Shared Burst Area Sold to


Many Customers

C Customer
D
A

B
12 E
OC
-N
13
LA
Vo N V
ice oI
Vid P In
eo ter
Da net
ta

11 STSNcDIP Pkts
STSNcDATM Cells
ATM Ethernet
Ds3-Leased Line
Ds1-Voice
TDM IP
Ds1-Voice

Some of the key benefits to IP+Optical technology are as follows:


■ Efficient transport of time-division multiplexing (TDM), packets, cells, and frames
through the reduction of packet overheads
■ Services aggregated on Synchronous Transport Signal level 1 (STS-1), the basic build-
ing block signal of SONET, operating at 51.84 Mbps (nxSTS1) and wavelengths pro-
viding for easy manageability and bandwidth management
■ Strong QoS and statistical multiplexing of bursty data traffic through existing support
in the IP protocol
■ Maintains existing Ethernet/IP/MPLS methods because these technologies are not
changed at all—merely layered directly onto the optical layer

Point-to-Point Dedicated
Dedicated point-to-point TLS circuits provide guaranteed bandwidth to the customer. This
allows for easily monitored service level agreement (SLA) offerings and network capacity
planning. Ethernet bandwidth is layered directly onto an STS circuit running across the opti-
cal network.
A point-to-point Ethernet service can be sent over an optical STS core, as shown in Figure 10-10.
The service is available with speeds of 10 Mbps, 100 Mbps, or 1000 Mbps. It can be pur-
chased in 1-Mbps increments.
1439_CCNP_3.book Page 658 Wednesday, October 27, 2004 9:54 AM

658 Chapter 10: Transparent LAN Services

Figure 10-10 Point-to-Point Ethernet Service Can Be Sent Over an Optical STS Core

15454
15454 15454
Catalyst Catalyst
CPE CPE
Dedicated STS
Circuit

The optical STS core can include the following:


■ Dedicated STS circuits between customers
■ 10/100/1000-Mbps connecting
■ Rate-limit service in 1-Mbps increments
■ STS-24c capacity for line-rate Gigabit Ethernet
■ STS-3c for Fast Ethernet
■ Unidirectional path-switched ring (UPSR) wavelength redundancy

Point-to-Multipoint Shared
Shared point-to-multipoint TLS circuits provide greater flexibility from the service provider’s
perspective. Shared point-to-multipoint TLS circuits allow for a large bandwidth circuit to be
created and additional drops to be added, necessitated by the acquisition of new customers.
Careful monitoring of bandwidth requirements prevents one drop from starving the others,
which is why QoS is important.
One of the best solutions for this design is in distributed campus models, where the customer
needs a large bandwidth connection between multiple geographically dispersed sites.
Figure 10-11 illustrates a shared multipoint TLS solution interconnecting three remote sites
on the right with the central site on the left. The shared multipoint TLS solution supports the
following options or features:
■ Hub-and-spoke connectivity
■ Same lambda for multiple links
■ VLAN association secures data
■ VLAN- and MPLS-VPN-enabled
1439_CCNP_3.book Page 659 Wednesday, October 27, 2004 9:54 AM

Introducing Transparent LAN Services Architecture 659

Figure 10-11 A Shared Multipoint TLS Solution Is an Option

Internet

15454
Catalyst
Core CPE
Route
7600 OSR 15454 15454
Redundancy Access
Wavelength
Redundancy

15454 15454

15454

Catalyst
CPE

15454
Catalyst
CPE

Role of QoS in TLS


QoS becomes an important part of the optical network with the implementation of TLS, espe-
cially with shared-bandwidth circuits. QoS is used to prevent one shared-bandwidth node
from starving the bandwidth from others and can also be used to guarantee certain levels of
service for all drops during times of peak usage (see Figure 10-12).

Figure 10-12 QoS Can Be Used to Guarantee Levels of Service for Customers

Trust Boundary
Central Campus
Remote Branch

Metro
MAN

QoS Campus Access QoS Campus Distribution QoS MAN/WAN QoS Branch

Table 10-2 defines the characteristics of QoS at the campus access layer, the campus distribu-
tion layer, in the MAN/wide area network (WAN), and within the remote branch.
1439_CCNP_3.book Page 660 Wednesday, October 27, 2004 9:54 AM

660 Chapter 10: Transparent LAN Services

Table 10-2 QoS Characteristics in an Optical Network Implementing TLS

QoS Campus QoS Campus


Access Distribution QoS MAN/WAN QoS Branch

Speed and duplex Layer 3 policing Multiple queues Classification and


settings trust boundaries on
IP phone, access
layer switch, and
router

Classification/trust Multiple queues on Low-latency Multiple queues on


on IP phone and all ports; priority queuing IP phone and all
access switch queuing for VoIP access ports

Multiple queues on WRED within data Link fragmentation


IP phone and access queue for conges- and interleave
ports tion management

Bandwidth provi-
sioning

Call admission
control

Customers using private shared bandwidth services to connect a distributed campus network
might also benefit from the implementation of QoS, because it allows customers to extend
their own QoS model across the WAN network to other sites.
To summarize, TLS provides for either dedicated point-to-point or shared point-to-multipoint
communication. IP+Optical reduces packet overhead, allowing increased bandwidth efficiency
and allowing TLS to be layered directly onto the optical layer. QoS plays a large role in TLS
networks, guaranteeing bandwidth to customers and nodes.

Examining Fiber-Optic Transports


This section discusses running Gigabit Ethernet over various transport mechanisms, such as
SONET, Dynamic Packet Transport (DPT), and DWDM.

Defining SONET and SDH


Synchronous Optical Network (SONET) and Synchronous Digital Hierarchy (SDH) are
standards for interfacing operating telephone company (OTC) optical networks. Together
they are a set of global standards that interface equipment from different vendors, as docu-
mented in Table 10-3.
Table 10-3 SONET and SDH Are Standards for Interfacing Optical Networks

SONET
Optical Electrical SDH Line Rate Payload Overhead
Level Level Equivalent (Mbps) Rate (Mbps) Rate (Mbps) SONET Capacity SDH Capacity

OC-1 STS-1 — 51.840 50.112 1.728 28 DS-1s or 1 DS-3s 21 E1s

OC-3 STS-3 STM-1 155.520 150.336 5.148 84 DS-1s or 3 DS-3s 63 E1s or 1 E4

OC-12 STS-12 STM-4 622.080 601.344 20.736 336 DS-1s or 12 252 E1s or 4 E4s
DS-3s

OC-48 STS-48 STM-16 2488.320 2405.376 82.944 1344 DS-1s or 1008 E1s or 16 E4s
1439_CCNP_3.book Page 661 Wednesday, October 27, 2004 9:54 AM

192 DS-3s

OC-192 STS-192 STM-64 9953.280 9621.504 331.776 5376 DS-1s or —


192 DS-3s

OC-768 STS-768 STM-256 39813.120 38486.016 1327.104 21504 DS-1s or 4032 E1s or 164
768 DS-3s E4s
Although an SDH STM-1 has the same bit rate as the SONET STS-3, the two signals contain different frame structures.
STM = Synchronous Transport Module (ITU-T)
STS = Synchronous Transport Signal (ANSI)
OC = Optical Carrier (ANSI)
DS = Digital Signal
Examining Fiber-Optic Transports
661
1439_CCNP_3.book Page 662 Wednesday, October 27, 2004 9:54 AM

662 Chapter 10: Transparent LAN Services

SDH is basically the international version of SONET, and SONET can be thought of as the
North American version of SDH. SDH is growing in popularity and is currently the main con-
cern, with SONET being considered as the variation. SONET’s popularity is not shrinking,
but SDH is gaining more and more popularity.
Both SONET and SDH can transport signals for all the networks in existence today, and they
have the flexibility to accommodate any networks defined in the future. They are used in three
traditional telecommunications areas: long-haul networks, local networks, and loop carriers.
They can also be used to carry cable TV (CATV) video traffic.
There are some slight differences between SONET and SDH. The main differences are in the
basic SDH and SONET frame formats, but SDH and SONET are essentially identical beyond
the STS-3 signal level. The base signal for SONET is STS-1, and the base signal for SDH is
STM-1. STS-3c is equivalent to STM-1, and the lower tributaries can be mapped inter-
changeably between the two formats from that point on.

STS-1
The Synchronous Transport Signal level 1 (STS-1) is SONET’s basic signal rate. SONET
adopts a frame length of 125 microns or a frame rate of 8000 octets per frame. Figure 10-13
shows the frame structure.

Figure 10-13 STS-1 Is the Basic Signal Rate for SONET


3 Bytes 87 Bytes

Section
Overhead
Path Overhead
9 Rows

STS-1 Payload

Line
Overhead

125 MS
Transport Synchronous Payload Envelope
Overhead

Each frame has 9 rows by 90 columns of octets, or bytes, forming a total of 810 octets per
frame. This gives SONET a basic transmission rate of 51.840 Mbps. Of the 810 total octets,
27 are dedicated overhead. The first 3 columns make up the transport overhead, where 9 bytes
are used for section overhead and 18 are used for line overhead. Columns 4 to 90 contain the
Synchronous Payload Envelope (SPE), where the STS-1 path overhead is found. Because
1439_CCNP_3.book Page 663 Wednesday, October 27, 2004 9:54 AM

Examining Fiber-Optic Transports 663

the first 3 columns are overhead, the actual data rate is 50.112 Mbps, rather than 51.840
Mbps. The STS-1 frame is transmitted starting from the byte in row 1 column 1 to the byte in
row 9 column 90. The most significant bit of a byte is transmitted first.
Higher line rates are obtained by synchronous multiplexing of the lower line rates. The STS-1
signal can be repeated N times, where valid values of N are 1, 3, 12, 48, and 192. Therefore,
STS-192 has a line rate as follows:
51.84 Mbps * 192 = 9953.28 Mbps

STM-1
The Synchronous Transport Module level 1 (STM-1) is the basic signal rate of SDH. Fig-
ure 10-14 shows the STM-1 frame structure.

Figure 10-14 STM-1 Is the Basic Signal Rate for SDH

Frame = 125 µs Frame = 125 µs Frame = 125 µs


1 Byte = One 64 kbit/s Channel
STM-1 = 270 Columns (2430 Bytes)

1
Regenerator
2 Section
Overhead
3

4 H1 H2 H3 Administrative Unit
Pointers H1H1H1 H2H2H2 H3H3H3
9 Rows
5 Capacity of the
Virtual Container
6

7 Multiplex
Section
Overhead
8

9
Overhead Width = 9 Columns

SDH also uses a frame length of 125 microns or a frame rate of 8000 octets per frame. The
STM-1 frame consists of overhead plus a virtual container (VC) capacity. Each frame has 9
rows by 270 columns of octets, or bytes, structure totaling 2430 octets per frame. Of the 2430
total octets, 81 are dedicated section overhead. The first 9 columns make up the section over-
head, and columns 10 to 270 make up the VC. The VC plus the pointers, H1, H2, and H3
bytes, is called the administrative unit (AU).
Carried within the VC capacity, which has its own frame structure of 9 rows and 261 col-
umns, are the path overhead and the container. The first column is for path overhead, and the
payload container follows it.
1439_CCNP_3.book Page 664 Wednesday, October 27, 2004 9:54 AM

664 Chapter 10: Transparent LAN Services

The STM frame is transmitted in a byte-serial fashion, row by row, like STS frames, and is
scrambled immediately before transmission to ensure adequate clock timing content for
downstream regenerators.
Regenerators extend a line’s maximum distance and quality by decomposing it into multiple
sections.

Applications for SONET/SDH


Optical networking has emerged as the foundation for campus, MAN, and WAN networking
with the capability to integrate voice, video, data, and storage over a single network, as illus-
trated in Figure 10-15.

Figure 10-15 Optical Networking Is Becoming the Foundation of Virtually All Networks Beyond the
Campus LAN Access Layer

Video
Networking
ONS
15327 Data
Networking

ONS
Storage 15327 ONS
Networking 15252
ONS
ONS 15454
15530
ONS
15252
ONS
15540
ONS
15540

Voice
Networking

SONET/SDH provides increased bandwidth and performance while facilitating data center,
application server, storage, and network infrastructure consolidation to optimize resources
and reduce costs. In addition, optical networking supports storage-area networking (SAN)
and IP-based network-attached storage (NAS) solutions to effectively access, manage, and
protect corporate data and to provide the foundation of business resilience applications.

Implementing SONET/SDH Within a Metropolitan Network


High-speed MAN services can be layered over an existing SONET infrastructure. This allows
for the smooth addition of services for the service provider and support for either point-to-
point dedicated bandwidth or point-to-multipoint shared bandwidth to downstream devices.
1439_CCNP_3.book Page 665 Wednesday, October 27, 2004 9:54 AM

Examining Fiber-Optic Transports 665

The network shown in Figure 10-16 depicts the construction of a SONET-based transparent
LAN network. The core is a SONET network, and the edge supports Ethernet. The Transport
Layer Security data traffic can be metered as well as supported under various SLAs.

Figure 10-16 Routers Are Connected to a SONET/SDH Infrastructure by Way of a Third Party

Customer Customer
Location CPE CPE Location

Router Service Router


or Provider or
Switch SONET Switch
Network

Customer- or Customer- or
Provider- Provider-
Controlled Serviced Provider Controlled Equipment Controlled
Equipment Equipment

The SONET/SDH infrastructure includes the following features:


■ Intrametro and intermetro
■ Dedicated secure bandwidth
■ STS-based circuits
■ 10/100/1000-Mbps access ports
■ Traffic metering via CPE
■ End-to-end SLA planning

Defining Dynamic Packet Transport (DPT)


Dynamic Packet Transport (DPT), illustrated in Figure 10-17, is a resilient packet ring tech-
nology designed to deliver scalable Internet service, reliable IP-aware optical transport, and
simplified network operations. For MAN applications, DPT-based solutions allow service
providers to scale and distribute their Internet and IP services across a reliable optical packet
ring infrastructure in a cost-effective manner. DPT is based on Spatial Reuse Protocol (SRP),
a Cisco-developed MAC-layer protocol for ring-based packet internetworking. Cisco has
submitted SRP to the IEEE 802.17 Resilient Packet Ring (RPR) Working Group for consider-
ation as a standard.
1439_CCNP_3.book Page 666 Wednesday, October 27, 2004 9:54 AM

666 Chapter 10: Transparent LAN Services

Figure 10-17 Dynamic Packet Transport Is a Resilient Packet Ring Technology

Working
BFP

DPT
Ring

Some of the benefits of DPT are as follows:


■ It replaces the complexity of SONET/SDH with the simplicity of Ethernet but retains
the main benefits of SONET/SDH.
■ It is an implementation of the Big Fat Pipe (BFP) concept. Bandwidth allocation is not
fixed. The system tries to use all available bandwidth as much as possible using statisti-
cal time-domain multiplexing.
■ It extends rich IP functionality over the metro area by replacing the legacy TDM nodes
with DPT nodes and mapping the physical topology into IP.
■ It significantly reduces the configuration management requirements because, from the
IP perspective, a DPT ring is as simple to handle as an Ethernet segment.
At the time this chapter was written, the IEEE 802.17 standards were still in draft form. The
new standard will use existing physical layer specifications (PHYs) and will develop new
PHYs where appropriate.

Defining CWDM and DWDM


Dense wavelength division multiplexing (DWDM) employs multiple light wavelengths to
transmit signals over a single optical fiber. Today, DWDM is a crucial component of optical
networks, because it maximizes the use of installed fiber cable and allows new services to be
quickly and easily provisioned over existing infrastructure. Flexible add/drop modules allow
individual channels to be dropped and inserted along a route. An open-architecture system
allows a variety of devices to be connected, including SONET terminals, ATM switches, and
IP routers. Figure 10-18 shows this.
1439_CCNP_3.book Page 667 Wednesday, October 27, 2004 9:54 AM

Examining Fiber-Optic Transports 667

Figure 10-18 CWDM and DWDM Permit Multiple Channels to Share the Same Optical Fiber, with
the Number of Channels Varying According to the Spacing of the Wavelengths

8-λ

16-λ
200 GHz

32-λ
100 GHz
195.9 1530.33

195.7 1531.90

195.5 1533.47

195.3 1535.04

195.1 1536.61

194.9 1538.19

194.7 1539.77

194.5 1541.30

194.3 1542.90

194.1 1544.50

193.9 1546.10

193.7 1547.72

193.5 1549.32

193.3 1550.02

193.1 1552.52

192.9 1554.13

192.7 1555.75

192.5 1557.36

192.3 1558.98

192.1 1560.60
196.1 1528.77

ITU-T G.692

(nm)
Wavelength
Grid

(THZ)
Coarse wavelength division multiplexing (CWDM) employs multiple light wavelengths to
transmit signals over a single optical fiber. CWDM technology is a crucial component of
Ethernet LAN and MAN networks, because it maximizes the use of installed fiber infrastruc-
ture at a very attractive price point.
CWDM technology is based on the same WDM concept as DWDM technology. The two
technologies differ primarily in the spacing of the wavelengths, number of channels, and the
capability to amplify signals in the optical space.

Implementing DWDM Over a MAN


The two largest problems facing service providers today in the metro environment are band-
width scalability and fiber exhaustion. Figure 10-19 illustrates unused portions of bandwidth
available on fiber links, or dark fiber.
DWDM addresses these needs through the use of wavelength multiplexing, as shown in
Figure 10-20. Wavelength multiplexing allows a service provider to offer virtual dark fiber to
individual wavelengths or lambdas as individual dark fibers. One fiber ring supports 16 indi-
vidual lambdas. In addition, each lambda can support up to OC-48 speeds, allowing for
unprecedented scalability and future growth.
1439_CCNP_3.book Page 668 Wednesday, October 27, 2004 9:54 AM

668 Chapter 10: Transparent LAN Services

Figure 10-19 Virtual Dark Fiber (Unused Fiber-Optic Bandwidth) and Bandwidth Scalability Are
Important Variables for Service Providers
OC-48/STM-16

OC-48

OC-48 Backbone Ring OC-48


_1-4
OC-48

_4
Digital Cross Connection

_12-16
OC-3 OC-12 _2
OC-3 Business Ring Metropolitan Ring OC-12
OC-3 OC-12
_1 _5-12
_1

OC-3/STM-1 OC-12/STM-4

Figure 10-20 DWDM Uses Wavelength Multiplexing


OC-48 Ring 10 Lambda
(up to 16 Lambda)

Satellite Headend
15200 Satellite 15200 Satellite
1 Lambda 10 Lambda
Projected Projected
Catalyst 3550-12G 7600IR
16-port Gb Card

Through the use of virtual fiber by DWDM, an existing fiber infrastructure can be segmented
to allow multiple service offerings, as shown in Figure 10-21. This allows for flexible net-
work topology offerings to the client and lower infrastructure costs to the service provider.
1439_CCNP_3.book Page 669 Wednesday, October 27, 2004 9:54 AM

Examining Fiber-Optic Transports 669

Figure 10-21 DWDM Optimizes the Use of the Existing Fiber Infrastructure

15454 CPE

15454
Aggregation

POP
7600 OSR

15454 Metro Core DWDM


GbE Connections

15454 15454

One fiber infrastructure can support a variety of service offerings and topologies:
■ Dedicated point-to-point Ethernet
■ Shared point-to-multipoint Ethernet
■ Internet-scale tiered bandwidth sharing
■ Access wavelength redundancy
■ Core route redundancy
■ Fully meshed Gigabit Ethernet backbones
■ VLAN and MPLS support for QoS offerings

10 Gigabit Ethernet Standards


Positioned as a high-speed technology for networking applications in LANs, MANs, and
WANs, 10 GbE provides very high bandwidth with simplicity and relatively low cost. In
LAN applications, 10 GbE lets network managers scale their packet-based networks from 10
Mbps to 10,000 Mbps and, thereby, leverage their investments in Ethernet as they increase
their networks’ performance. In MAN and WAN applications, 10 GbE lets Internet service
providers (ISPs) and network service providers (NSPs) create very high-speed links at very
low cost between collocated carrier-class switches and routers.
1439_CCNP_3.book Page 670 Wednesday, October 27, 2004 9:54 AM

670 Chapter 10: Transparent LAN Services

In the Open System Interconnection (OSI) model, Ethernet is fundamentally a Layer 2 proto-
col. 10 GbE uses the IEEE 802.3 Ethernet Media Access Control (MAC) protocol, the IEEE
802.3 Ethernet frame format, and the minimum and maximum IEEE 802.3 frame size. Just as
1000BASE-X and 1000BASE-T (Gigabit Ethernet) remained true to the Ethernet model, 10
GbE continues the natural evolution of Ethernet in speed and distance. Because it is a full
duplex-only and fiber-only technology, 10 GbE does not need the carrier sense multiple
access/collision detect (CSMA/CD) access method that defines slower, half-duplex Ethernet
technologies. In every other respect, 10 GbE remains true to the original Ethernet model. An
Ethernet physical layer device, which corresponds to Layer 1 of the OSI model, connects the
media, optical or copper, to the MAC layer, which corresponds to OSI Layer 2. Ethernet
architecture further divides Layer 1 into a physical media dependent (PMD) and a physical
coding sublayer (PCS). Optical transceivers, for example, are PMDs. The PCS is made up of
coding algorithms and a serializer and often implements multiplexing functions.
The 802.3ae 10 Gigabit Ethernet specification defines two physical layer types, such as the
LAN and WAN PHYs illustrated in Figure 10-22. The WAN PHY has an extended feature set
added onto the functions of a LAN PHY. These PHYs are solely distinguished by the PCS.

Figure 10-22 The LAN and WAN PHY for 10 GbE Are Specified in the IEEE 802.3ae Specification

IEEE 802.3 Media Access Control (MAC)


Full Duplex

10 Gigabit Media Independent Interface (XGMII) or


10 Gigabit Attachment Unit Interface (XAUI)

CWDM Serial Serial


LAN PHY LAN PHY WAN PHY
(8 B/10 B) (64 B/66 B) (64 B/66 B + WIS)

CWDM CWDM CWDM CWDM CWDM CWDM CWDM


PMD PMD PMD PMD PMD PMD PMD
1310 nm 850 nm 1310 nm 1550 nm 850 nm 1310 nm 1550 nm

10 Gigabit Ethernet – IEEE 802.3ae

The WAN PHY differs from the LAN PHY by the inclusion of a simplified SONET framer.
Because SONET OC-192 is within a few percent of 10 Gbps, it is simple to implement a
MAC to be able to operate with a LAN PHY at 10 Gbps or a WAN PHY at the SONET
OC-192 payload rate. To enable low-cost WAN PHY implementations, the IEEE 802.3ae
committee specifically rejected conformance to SONET jitter, stratum clock, and other
1439_CCNP_3.book Page 671 Wednesday, October 27, 2004 9:54 AM

Summary 671

SONET optical specifications. Therefore, the WAN interface sublayer (WIS) does not render
a 10 GbE WAN PHY compliant with either SONET or SDH at any rate or format.
The LAN PHY is the most cost-effective solution to support the existing 10 GbE applica-
tions across LAN and MAN distances on dark fiber and dark wavelengths. However, it lacks
the capability to speak the same language as the synchronous TDM gear most prevalent in the
WAN environment. The WAN PHY can be used to connect Ethernet-based networks to the
existing SONET/SDH TDM and DWDM infrastructure and support lit wavelengths and lit
fiber over WAN distances.
The expectation is that the LAN PHY will also be used in pure optical switching environ-
ments extending over long-haul distances. This is possible because, by using optical equip-
ment that incorporates the capability to transparently carry any higher-level technologies,
such as 10 GbE, ATM, SONET, SDH, and so on, LAN and TDM services will seamlessly
converge into a single optical infrastructure. This infrastructure will provide Layer 1 transport
across MAN/WAN distances and will offer carrier-grade reliability while remaining com-
pletely technology-agnostic. Therefore, the importance of the WAN PHY for long-haul appli-
cations will also diminish.

Summary
Transparent LAN services provide up to 10-Gbps WAN connectivity across a wide geo-
graphic region, typically comprising a metropolitan area. The connectivity provided by TLS
has the appearance of being realized over a local LAN while actually covering a wide geo-
graphic area. In particular, TLS lets VLANs span a MAN.
TLS can run over most high-speed WAN transports, such as SONET, SDH, and DPT. The
Cisco implementation of TLS features Gigabit Ethernet or 10 GbE running over the underly-
ing WAN transport.
1439_CCNP_3.book Page 672 Wednesday, October 27, 2004 9:54 AM

672 Chapter 10: Transparent LAN Services

Key Terms
coarse wavelength division multiplexing (CWDM) A technology that employs multiple
light wavelengths to transmit signals over a single optical fiber. CWDM technology is based
on the same WDM concept as DWDM technology. The two technologies differ primarily in
the spacing of the wavelengths, the number of channels, and the capability to amplify signals
in the optical space.
dense wavelength division multiplexing (DWDM) A technology that employs multiple
light wavelengths to transmit signals over a single optical fiber.
Dynamic Packet Transport (DPT) A resilient packet ring technology designed to deliver
scalable Internet service, reliable IP-aware optical transport, and simplified network
operations.
Synchronous Digital Hierarchy (SDH) A standard for interfacing operating telephone
company optical networks. SDH and SONET form a set of global standards that interface
equipment from different vendors.
Synchronous Optical Network (SONET) A standard for interfacing operating telephone
company optical networks. SONET and SDH form a set of global standards that interface
equipment from different vendors.
Transparent LAN Services (TLS) A set of technologies that lets the service provider offer
the customer native LAN services over wide-area links without the need to implement com-
plicated and costly ATM networks.
VLAN tunneling A technology that allows customers in a metro environment to extend
their logical network topology across wide geographic areas.

Check Your Understanding


Use the following review questions to test your understanding of the concepts covered in this
chapter. Answers are listed in Appendix A, “Check Your Understanding Answer Key.”
1. TLS solutions can be much less costly than which of the following traditional WAN
solutions while providing equivalent or improved service?
A. ATM

B. ISDN

C. Frame Relay

D. X.25
1439_CCNP_3.book Page 673 Wednesday, October 27, 2004 9:54 AM

Check Your Understanding 673

2. What can be used to connect Ethernet-based networks to an existing SONET/SDH and


TDM and DWDM infrastructure?
A. PCS

B. CSMA/CD

C. WAN PHY

D. PMD
3. Which two LAN and WAN technologies can be integrated relatively easily because of
their comparable bandwidths?
A. Fast Ethernet and OC-3

B. Gigabit Ethernet and STS-1

C. 10 Gigabit Ethernet and OC-192

D. Standard Ethernet and STS-3


4. What is the maximum speed available with SONET?

A. OC-48

B. OC-192

C. OC-384

D. OC-768
5. What three areas are defined by a segmented metro network?

A. Aggregation point for forwarding

B. CPE

C. LAN

D. POP
6. What three service options are available with metro Ethernet?

A. High-speed Internet access

B. High-speed VPN access

C. Remote access

D. Point-to-point LAN service


1439_CCNP_3.book Page 674 Wednesday, October 27, 2004 9:54 AM

674 Chapter 10: Transparent LAN Services

7. Which of the following technologies removes the need to layer SONET or ATM tech-
nologies between a Layer 3 protocol and the optical physical layer?
A. TLS

B. 10 GEC

C. IP+Optical

D. TDM+Optical
8. What Cisco device can be configured to provide shared point-to-multipoint TLS?

A. Catalyst 6500 NAM

B. PIX 515

C. ONS 15454

D. Cisco 7600 router


9. Which of the following is a QoS feature commonly implemented in metro optical
networks?
A. Bandwidth provisioning

B. CoS-to-DSCP mapping

C. Priority queuing

D. Compression
10. How many bytes are there per SONET frame?

A. 210

B. 410

C. 810

D. 1610
1439_CCNP_3.book Page 675 Wednesday, October 27, 2004 9:54 AM
1439_CCNP_3.book Page 676 Monday, November 1, 2004 11:16 AM
1439_CCNP_3.book Page 677 Wednesday, October 27, 2004 9:54 AM

Appendix A

Check Your Understanding


Answer Key
Chapter 1
1. Which of the following are key requirements in a modern campus network?

A. Redundancy
B. Scalability

C. 80/20 rule

D. Multicasting

Answer: A, B, D
2. Which of the following is not a category of service in a campus network?

A. Local
B. Geographic

C. Remote

D. Enterprise
Answer: B
3. Which of the following layers typically involve Layer 3 switching?

A. Access
B. Distribution

C. Session

D. Core

Answer: B, D
1439_CCNP_3.book Page 678 Wednesday, October 27, 2004 9:54 AM

678 Appendix A: Check Your Understanding Answer Key

4. What layer is the point at which end users are allowed into the network?

A. Access
B. Distribution

C. Session

D. Core

Answer: A
5. Which of the following are backbone campus network solutions?
A. Layer 2 switching
B. Layer 3 switching

C. Layer 4 switching

D. ATM
Answer: A, B, D
6. What type of cable is used to configure Catalyst 2950 switches through a console
connection?
A. Coaxial
B. Straight-through

C. Crossover

D. Rollover

Answer: D
7. What type of UTP cable can be used to connect FastEthernet ports on two
Catalyst 3550 switches?
A. Coaxial
B. Straight-through

C. Crossover

D. Rollover

Answer: C
1439_CCNP_3.book Page 679 Wednesday, October 27, 2004 9:54 AM

Chapter 2 679

8. What two commands are used to restore a Catalyst 3550 switch to a default configuration?

A. delete startup-config
B. erase startup-config

C. delete vlan.dat

D. erase vlan.dat

Answer: B, C
9. Which of the following commands are used with password recovery on a Catalyst 2950
switch?
A. flash_init
B. load_helper

C. rename

D. boot

Answer: A, B, C, D
10. What command is used to set the port speed to 100 on a Catalyst 3550 10/100
interface?
A. set speed
B. speed

C. bandwidth

D. set bandwidth

Answer: B

Chapter 2
1. For which of the following VTP modes does a Catalyst switch listen to VTP
advertisements?
A. Client
B. Server

C. Transparent

D. Peer

Answer: A, B
1439_CCNP_3.book Page 680 Wednesday, October 27, 2004 9:54 AM

680 Appendix A: Check Your Understanding Answer Key

2. Which of the following are Cisco-proprietary protocols?

A. CDP
B. VQP

C. VTP

D. ISL

Answer: A, B, C, D
3. Which of the following are VLAN trunking methods?
A. ATM LANE
B. IEEE 802.10

C. IEEE 802.1Q

D. ISL
Answer: A, B, C, D
4. Two devices in the same VLAN require a Layer 3 switch to communicate. What
campus design model is used?
A. Remote VLANs
B. Campus VLANs

C. Local VLANs

D. End-to-end VLANs

Answer: C
5. Which of the following are required for dynamic VLAN assignment to ports with
VMPS?
A. VQP
B. VMPS server

C. VMPS client

D. TFTP server

Answer: A, B, C, D
1439_CCNP_3.book Page 681 Wednesday, October 27, 2004 9:54 AM

Chapter 2 681

6. Which VLAN database configuration mode command is used to remove VLAN 20?

A. erase vlan 20
B. clear vlan 20

C. delete vlan 20

D. no vlan 20

Answer: D
7. What is the operational mode of a link when both ends are configured as dynamic
desirable?
A. Trunk
B. Static access

Answer: A
8. What three commands are used to restore a Catalyst 3550 switch to a default configuration?

A. copy running-config startup-config


B. erase startup-config

C. delete vlan.dat

D. reload

Answer: B, C, D
9. Which construct can be used to filter both intra-VLAN and inter-VLAN traffic?

A. Router ACL
B. VLAN map

C. IOS ACL

D. Port ACL

Answer: B
10. Which of the following messages are used with VTP?

A. Join messages
B. Advertisement requests

C. Subset advertisements

D. Summary advertisements

Answer: A, B, C, D
1439_CCNP_3.book Page 682 Wednesday, October 27, 2004 9:54 AM

682 Appendix A: Check Your Understanding Answer Key

Chapter 3
1. Which of the following is used in Root Switch election?
A. Port ID
B. Path cost

C. Bridge ID

D. Port priority

Answer: C
2. What are the three steps of STP convergence?
A. Elect a Root Switch
B. Elect Designated Ports

C. Elect Blocking Ports

D. Elect Root Ports

Answer: A, B, D
3. On an IOS-based switch, the Port ID is a 16-bit ordered pair composed of what two values?
A. Port Preference
B. Port Priority

C. Port Number

D. Port Cost

Answer: B, C
4. The Bridge ID is an 8-byte ordered pair composed of what two values?
A. Bridge Priority
B. Bridge preference

C. Bridge number

D. MAC address

Answer: A, D
5. Every active trunk port on the Root Switch is which of the following?
A. Root Port
B. Non-Designated Port

C. Designated Port

D. Blocking Port

Answer: C
1439_CCNP_3.book Page 683 Wednesday, October 27, 2004 9:54 AM

Chapter 3 683

6. Which of the following are IEEE 802.1D spanning-tree states?

A. Blocking
B. Discarding

C. Learning

D. Forwarding

E. Listening

Answer: A, C, D, E
7. Which of the following are IEEE 802.1w spanning-tree states?

A. Blocking
B. Listening

C. Learning

D. Forwarding

E. Discarding

Answer: C, D, E
8. Multiple Spanning Tree is specified by which IEEE standard?

A. 802.1D
B. 802.1w

C. 802.1Q

D. 802.1s

Answer: D
9. Which of the following spanning-tree parameters can be used to enable load sharing?

A. Port Priority
B. Bridge Priority

C. EtherChannel

D. Path Cost

Answer: A, B, D
1439_CCNP_3.book Page 684 Wednesday, October 27, 2004 9:54 AM

684 Appendix A: Check Your Understanding Answer Key

10. Which of the following are the two protocols used to create Ethernet channels or
bundles?
A. LACP
B. VQP

C. DTP

D. PAgP

Answer: A, D

Chapter 4
1. Which of the following are options that are available for inter-VLAN routing?

A. Adding a route processor to a chassis-based switch with a daughter card or module


B. Router-on-a-stick

C. One router-to-switch link per VLAN

D. Fixed chassis (nonmodular) multilayer switch

Answer: A, B, C, D
2. What is required in a Layer 2 core with physical loops?

A. Routing protocol
B. HSRP

C. STP

D. VTP

Answer: C
3. What is the most scalable inter-VLAN routing option?

A. Layer 2 switch
B. Layer 3 switch

C. Router

D. Router-on-a-stick

Answer: B
1439_CCNP_3.book Page 685 Wednesday, October 27, 2004 9:54 AM

Chapter 4 685

4. Which of the following are examples of modules or daughter cards that provide routing
functionality in a chassis-based Catalyst switch?
A. Multilayer Switch Module
B. Route Switch Feature Card

C. Route Switch Module

D. Multilayer Switch Feature Card

Answer: A, B, C, D
5. Which of the following modules have embedded route processors?

A. Catalyst 6500 Supervisor Engine 720


B. Catalyst 4006 Supervisor Engine II

C. Catalyst 4500 Supervisor Engine III

D. Catalyst 4500 Supervisor Engine IV

Answer: A, C, D
6. Which of the following are required for performing router-on-a-stick?

A. Router
B. IEEE 802.1Q or ISL

C. Routing protocol

D. Layer 2 switch port

Answer: A, B, D
7. A switch virtual interface is configured with what command(s)?

A. Switch#vlan database
B. Switch(vlan)#vlan

C. Switch(config)#interface vlan

D. Switch(config)#vlan

Answer: C
1439_CCNP_3.book Page 686 Wednesday, October 27, 2004 9:54 AM

686 Appendix A: Check Your Understanding Answer Key

8. What command is required to configure a switch port on a multilayer Catalyst switch as


a routed port?
A. ip routing
B. no shutdown

C. interface vlan

D. no switchport

Answer: D
9. Before Cisco IOS software Release 12.1(3)T, the native VLAN was configured on
which interface on a router?
A. Physical interface
B. Subinterface

C. Switch virtual interface

D. Bridge virtual interface

Answer: A
10. What Catalyst 3550 commands can be used to determine whether a port is a routed port
or a Layer 2 switch port?
A. show port routed
B. show ip interface switchport

C. show vlan

D. show ip interface brief

Answer: B, D

Chapter 5
1. Which of the following describe multilayer switching?

A. It’s hardware-based.
B. It performs PDU header rewrites and forwarding.

C. It’s platform-independent.

D. It uses Layer 2, 3, and 4 header information.

Answer: A, B, D
1439_CCNP_3.book Page 687 Wednesday, October 27, 2004 9:54 AM

Chapter 5 687

2. Which of the following device combinations support Cisco Express Forwarding?

A. Cisco 7500 router running IOS 12.0


B. Catalyst 4500 Supervisor Engine III

C. Catalyst 6500 MSFC2

D. Cisco routers running IOS 12.2 or later

Answer: A, B, C, D
3. Which of the following are MLS components?
A. MLSP
B. MLS-RP

C. MLS cache

D. MLS-SE
Answer: A, B, D
4. Which of the following are MLS flow masks?

A. destination-ip
B. protocol-flow

C. source-destination-ip

D. ip-flow

Answer: A, C, D
5. After an IP MLS flow has been created, which of the following fields change in a frame
traversing the MLS-SE as part of the same flow?
A. Source MAC address
B. Destination MAC address

C. TTL

D. Source IP

Answer: A, B, C
6. In addition to the routing table, what tables are created in the CEF-based model?

A. Routing table
B. Forwarding Information Base

C. Content flow table

D. Adjacency table

Answer: A, B, D
1439_CCNP_3.book Page 688 Wednesday, October 27, 2004 9:54 AM

688 Appendix A: Check Your Understanding Answer Key

7. How many leaves are possible in a CEF Forwarding Information Base?

A. 32
B. 64

C. 128

D. 256

Answer: D
8. How many MLS-SE commands are required to configure MLS when the MLS-RP is an
external router?
A. 1
B. 2

C. 3

D. 4

Answer: B
9. What is the default MLS flow mask when no ACLs are configured on the MLS-RP?

A. destination-ip
B. protocol-flow

C. source-destination-ip

D. ip-flow

Answer: A
10. What global configuration command enables CEF?

A. cef run
B. enable cef

C. cef enable

D. ip cef

Answer: D

Chapter 6
1. With redundant Supervisor Engines and MSFCs in a Catalyst 6500 switch running
SRM, which of the following statements is accurate?
A. The nondesignated MSFC is active and has the same configuration as the
designated MSFC.
1439_CCNP_3.book Page 689 Wednesday, October 27, 2004 9:54 AM

Chapter 6 689

B. The nondesignated MSFC is inactive and has the same configuration as the
designated MSFC.
C. The nondesignated MSFC is inactive and has a configuration distinct from the
designated MSFC.
D. The nondesignated MSFC is active and has a configuration distinct from the
designated MSFC.
Answer: B
2. The GLBP router responsible for allocating MAC addresses is which of the following?

A. Active virtual gateway


B. Active virtual forwarder

C. Primary virtual forwarder


D. Secondary virtual forwarder

Answer: A
3. The GLBP router responsible for forwarding packets sent to a particular MAC address
is which of the following?
A. Active virtual gateway
B. Active virtual forwarder

C. Primary virtual forwarder

D. Secondary virtual forwarder

Answer: B
4. Which IETF standard introduced in RFC 2338 parallels the Cisco-proprietary HSRP?

A. HSRP 2
B. IRDP

C. GLBP

D. VRRP

Answer: D
5. How many virtual MAC addresses are used per HSRP group?

A. 1
B. 2

C. 3

D. 4

Answer: A
1439_CCNP_3.book Page 690 Wednesday, October 27, 2004 9:54 AM

690 Appendix A: Check Your Understanding Answer Key

6. SLB is an IOS-based solution defining a virtual server that represents a group of what?

A. Real servers in separate intranets


B. Virtual servers in a server farm

C. Real servers in a server farm

D. Virtual servers in separate intranets

Answer: C
7. How many standby routers can there be in a given HSRP group?
A. 1
B. 2

C. 3

D. 4
Answer: A
8. HSRP can be configured on distribution layer Catalyst 3550 switches using switch vir-
tual interfaces. However, on distribution layer routers, multigroup HSRP is configured
on trunk links using what?
A. Null interfaces
B. Loopbacks

C. Bridge virtual interfaces

D. Subinterfaces

Answer: D
9. When configuring HSRP, each HSRP router interface must be configured with which of
the following? (Select all that apply.)
A. A virtual MAC address
B. A real MAC address

C. A virtual IP address

D. A real IP address

Answer: C, D
10. Which HSRP option(s) is/are used to guarantee an immediate change to active state on
an HSRP router?
A. preempt
B. tracking
1439_CCNP_3.book Page 691 Wednesday, October 27, 2004 9:54 AM

Chapter 7 691

C. priority

D. hello time

Answer: A, C

Chapter 7
1. What type of VLAN is commonly used with Catalyst switches to support IP phones?

A. User VLAN
B. Native VLAN

C. Auxiliary VLAN

D. Management VLAN

Answer: C
2. Which of the following is an indispensable software-based call-processing component
required for a Cisco IP Telephony solution?
A. LDAP
B. Gateserver

C. IOS Gatekeeper

D. CallManager

Answer: D
3. Different codecs have different encoding delays. These delays are added to the end-
point-to-codec delays to determine which of the following?
A. Propagation delay
B. Latency

C. Initialization delay

D. End-to-end delay

Answer: D
1439_CCNP_3.book Page 692 Wednesday, October 27, 2004 9:54 AM

692 Appendix A: Check Your Understanding Answer Key

4. A priority queue is established for what type of traffic when implementing QoS for an
IP telephony solution?
A. TCP
B. UDP

C. Data

D. Voice

Answer: D
5. Layer 2 traffic classification uses which of the following?

A. Type of service
B. Class of service

C. Differentiated Services Code Point

D. Voice queue

Answer: B
6. Layer 3 traffic classification uses which of the following?

A. Type of service
B. Class of service

C. Differentiated Services Code Point

D. Voice queue

Answer: A, C
7. What is used to ensure that multicast traffic is correctly forwarded down the
distribution tree?
A. LCP
B. CRTP

C. RTP

D. RPF

Answer: D
8. What are the two types of multicast distribution trees?

A. CBT trees
B. Shared trees
1439_CCNP_3.book Page 693 Wednesday, October 27, 2004 9:54 AM

Chapter 8 693

C. Shortest-path trees

D. Rendezvous trees

Answer: B, C
9. What Layer 2 multicast address corresponds to the Layer 3 multicast address 224.10.8.5?

A. FF.FF.FF.FF.FF.FF
B. 01.00.22.44.10.05

C. 01.00.5E.0A.08.05

D. 01.00.5E.10.08.05

Answer: C
10. What multicast protocol is used to optimize multicast traffic between hosts and routers
participating in multicast traffic flows?
A. RGMP
B. IGMP

C. CGMP

D. PIM-SM

Answer: B

Chapter 8
1. What QoS characteristics define the quality of the movement of traffic from one point
to another?
A. Bandwidth
B. Jitter

C. Loss

D. Delay

Answer: B, C, D
2. Loss for voice traffic should not exceed what percentage?

A. .5 percent
B. 1 percent

C. 2 percent

D. 4 percent

Answer: B
1439_CCNP_3.book Page 694 Wednesday, October 27, 2004 9:54 AM

694 Appendix A: Check Your Understanding Answer Key

3. Latency for video traffic should be no more than how many seconds?

A. 2 to 3 seconds
B. 3 to 4 seconds

C. 4 to 5 seconds

D. 5 to 6 seconds

Answer: C
4. Which of the following are the three QoS service models?
A. Deterministic
B. Best-effort

C. DiffServ

D. IntServ
Answer: B, C, D
5. How many bits are used to indicate IP Precedence?

A. 2
B. 3

C. 6

D. 8

Answer: B
6. How many bits are used to indicate IP DSCP?

A. 2
B. 3

C. 6

D. 8

Answer: C
7. The CoS is set to which of the following values on traffic sourced by a Cisco IP Phone?

A. 0
B. 1

C. 5

D. 7

Answer: C
1439_CCNP_3.book Page 695 Wednesday, October 27, 2004 9:54 AM

Chapter 9 695

8. What type of QoS is used to prevent tail drop from causing traffic irregularities?

A. RSVP
B. GTS

C. WRED

D. CAR

Answer: C
9. Where in a network should traffic be marked? (Select all that apply.)
A. Edge router
B. Core router

C. Access router

D. Distribution router
Answer: A, C
10. What type of queuing is designed specifically for voice traffic?

A. CBWFQ
B. FIFO

C. WFQ

D. LLQ

Answer: D

Chapter 9
1. Which of the following are valid SPAN source ports?

A. Layer 2 port
B. Layer 3 port

C. EtherChannel

D. Trunk port

Answer: A, B, C, D
2. An RSPAN session requires the use of what type of port(s)?

A. Source port
B. Destination port
1439_CCNP_3.book Page 696 Wednesday, October 27, 2004 9:54 AM

696 Appendix A: Check Your Understanding Answer Key

C. Trunk port

D. Reflector port

Answer: A, B, C, D
3. What Catalyst 6500 module is used to store and modify monitored traffic?

A. Intrusion Detection Sensor


B. Switch Fabric Module

C. Network Analysis Module

D. Supervisor Engine

Answer: C
4. What is the web interface used with the NAM called?

A. Netsys Baseliner
B. RMON 2 Viewer

C. RMON Viewer

D. NAM Traffic Analyzer

Answer: D
5. The Switch Fabric Module is used on which Catalyst switches?

A. 2950
B. 3550

C. 6500

D. 7600

Answer: C
6. Basic security measures include which considerations?

A. Physical security
B. Privilege level

C. Remote access

D. Password protection

Answer: A, B, C, D
7. The CoS is set to what value on traffic sourced by a Cisco IP Phone?

A. 0
B. 1
1439_CCNP_3.book Page 697 Wednesday, October 27, 2004 9:54 AM

Chapter 10 697

C. 5

D. 7

Answer: C
8. Out-of-band management is performed on what lines or interfaces?

A. Ethernet
B. Console

C. Auxiliary

D. vty

Answer: B, C
9. Secure Shell requires the use of what command(s)?

A. ip domain-name
B. crypto key generate rsa

C. ssh

D. login local

Answer: A, B
10. What type of access list filters both routed and bridged traffic?

A. MAC ACL
B. Port ACL

C. VLAN map

D. Router ACL

Answer: C

Chapter 10
1. TLS solutions can be much less costly than which of the following traditional WAN
solutions while providing equivalent or improved service?
A. ATM
B. ISDN

C. Frame Relay

D. X.25

Answer: A
1439_CCNP_3.book Page 698 Wednesday, October 27, 2004 9:54 AM

698 Appendix A: Check Your Understanding Answer Key

2. What can be used to connect Ethernet-based networks to an existing SONET/SDH and


TDM and DWDM infrastructure?
A. PCS
B. CSMA/CD

C. WAN PHY

D. PMD

Answer: C
3. Which two LAN and WAN technologies can be integrated relatively easily because of
their comparable bandwidths?
A. Fast Ethernet and OC-3
B. Gigabit Ethernet and STS-1

C. 10 Gigabit Ethernet and OC-192

D. Standard Ethernet and STS-3

Answer: C
4. What is the maximum speed available with SONET?

A. OC-48
B. OC-192

C. OC-384

D. OC-768

Answer: D
5. What three areas are defined by a segmented metro network?

A. Aggregation point for forwarding


B. CPE

C. LAN

D. POP

Answer: A, B, D
6. What three service options are available with metro Ethernet?

A. High-speed Internet access


B. High-speed VPN access
1439_CCNP_3.book Page 699 Wednesday, October 27, 2004 9:54 AM

Chapter 10 699

C. Remote access

D. Point-to-point LAN service

Answer: A, B, D
7. Which of the following technologies removes the need to layer SONET or ATM tech-
nologies between a Layer 3 protocol and the optical physical layer?
A. TLS
B. 10 GEC

C. IP+Optical

D. TDM+Optical

Answer: C
8. What Cisco device can be configured to provide shared point-to-multipoint TLS?
A. Catalyst 6500 NAM
B. PIX 515

C. ONS 15454

D. Cisco 7600 router

Answer: C
9. Which of the following is a QoS feature commonly implemented in metro optical
networks?
A. Bandwidth provisioning
B. CoS-to-DSCP mapping

C. Priority queuing

D. Compression

Answer: A
10. How many bytes are there per SONET frame?

A. 210
B. 410

C. 810

D. 1610

Answer: C
1439_CCNP_3.book Page 700 Monday, November 1, 2004 11:16 AM
1439_CCNP_3.book Page 701 Wednesday, October 27, 2004 9:54 AM

Appendix B

Gigabit Ethernet and 10 Gigabit


Ethernet Standards and
Operation
The demand for bandwidth continues to grow as new applications and services are added to
existing networks. More than 85 percent of workstations are presently running Fast Ethernet,
driving the need for servers with Gigabit connections. Industry expectation is that autonegotiating
10/100/1000-Mbps network interface cards (NICs) will enjoy almost complete market share
by 2005. With users simultaneously editing a remote Structured Query Language (SQL) database,
downloading MP3 files, sending an e-mail with a 10-MB attachment, and conducting a NetMeeting
conference call over a multicast-enabled IP network, it’s not surprising that Gigabit Ethernet is
making its way to the desktop.
In the late 1990s, Gigabit Ethernet standards were approved for copper cable (IEEE 802.3ab)
and fiber media (IEEE 802.3z), carrying on a 25-year tradition. Gigabit Ethernet options are now
common for campus network devices, including switches, routers, servers, and desktops.
With more than 85 percent of the installed base of network ports using Ethernet, the job of the
network engineer is in some sense simplified with the increased availability of Gigabit Ethernet
products. As the standards for Ethernet evolve, backward compatibility with 10-Mbps and 100-Mbps
Ethernet installations continues to be maintained. More than 90 percent of existing Category 5
installations already meet the minimum requirements for deploying Gigabit Ethernet, so upgrad-
ing to Gigabit Ethernet is often just a matter of adding or swapping modules in a switch chassis.
The familiarity of Ethernet also serves as a psychological advantage for deploying Gigabit Ethernet.
Most network engineers are much more comfortable with Ethernet deployments as compared to
other LAN/MAN technologies. Ethernet is easy to use and easy to upgrade. The process of
upgrading typically proceeds from the campus backbone to the server farm to the desktop.
1439_CCNP_3.book Page 702 Wednesday, October 27, 2004 9:54 AM

702 Appendix B: Gigabit Ethernet and 10 Gigabit Ethernet Standards and Operation

Another advantage of Gigabit Ethernet is its support of quality of service (QoS) features such
as IEEE 802.1p traffic prioritization that enhance audio and video communication. QoS is
now pervasive in modern networks as voice, video, and data networks converge. This book
does not delve into the array of QoS options for optimizing network traffic flow, but you are
strongly encouraged to begin your study of QoS as soon as possible to stay current in the field.
More than increased bandwidth, ease of upgrades, or QoS options, the small cost-versus-
bandwidth ratio of Gigabit Ethernet is the primary reason for its success. The bottom line
generally serves as the deciding factor in major network upgrades.

Gigabit Ethernet Standards


The original 10-Mbps Ethernet standards were devised more than 25 years ago. Among these
is 10BASE-T (supported by Category 3, 4, and 5 cable).
The 10BASE-T standards were followed by the IEEE 802.3u Fast Ethernet standards. Fast
Ethernet includes specifications for 100BASE-T (Category 5 cable with pins 1 and 2 for trans-
mission and pins 3 and 6 for receiving and collision detection), 100BASE-T4 (Category 3 cable
using all four wire pairs), and 100BASE-FX (multimode or single-mode fiber used, for exam-
ple, between buildings or in areas where there are high levels of radiated electrical noise).
Gigabit Ethernet standards have been in place since the late 1990s. Gigabit Ethernet ports are
now as commonplace as 10-Mbps ports were in the early 1990s. The IEEE 802.3z standard
specifies 1000 Mbps over fiber, and the IEEE 802.3ab standard specifies 1000 Mbps over
Category 5 cable (1000BASE-T). The 802.3ab standard also supports 1000 Mbps over the
EIA/TIA Category 5e specification. Figure B-1 summarizes the Gigabit Ethernet standards.

History of the Gigabit Ethernet Standards Process


More than a decade ago, the old 10BASE5 and 10BASE2 Ethernet networks were replaced
by 10BASE-T hubs, allowing for greater manageability of the network and the cable plant.
As applications increased the demands on the network, newer high-speed protocols such as
Fiber Distributed Data Interface (FDDI) and Asynchronous Transfer Mode (ATM) became
available. However, Fast Ethernet became the backbone of choice because of its simplicity
and its backward compatibility with Ethernet. The primary goal of Gigabit Ethernet was to
build on that topology and knowledge base to create a higher-speed technology without forcing
customers to throw away existing networking equipment.
1439_CCNP_3.book Page 703 Wednesday, October 27, 2004 9:54 AM

Gigabit Ethernet Standards 703

Figure B-1 IEEE 802.3z and IEEE 802.3ab Comprise the Gigabit Ethernet Standards

IEEE 802.3z (June 1998)


IEEE 802.3ab (June 1999)

Media Access Control (MAC)


Full Duplex/Half Duplex

GMII - Gigabit Media Independent Interface


(Similar to AUI)
MAC
Fiber Channel Copper PHY
PHY Encoder/Decoder Encoder/Decoder

Singlemode Multimode Short-Haul Long-Haul


Fiber - 5 km Fiber - 550 m Copper - 25 m Copper - 100 m
1000BASE-LX 1000BASE-SX 1000BASE-CX 1000BASE-T

The standards body that worked on Gigabit Ethernet was called the Institute of Electrical and
Electronics Engineers (IEEE) 802.3z Task Force. The possibility of a Gigabit Ethernet Stan-
dard was raised in mid-1995 after the final ratification of the Fast Ethernet standard. By
November 1995, there was enough interest to form a high-speed study group. This group met
at the end of 1995 and several times during early 1996 to study the feasibility of Gigabit Ether-
net. The meetings grew in attendance, reaching 150 to 200 individuals. Numerous technical
contributions were offered and evaluated.
In July 1996, the 802.3z Task Force was established with the charter to develop a standard for
Gigabit Ethernet. Basic concept agreement on technical contributions for the standard was
achieved at the November 1996 IEEE meeting. The first draft of the standard was produced
and reviewed in January 1997, and the final standard was approved in June 1998. The IEEE
802.3ab standard for Gigabit Ethernet over copper cable was approved one year later in
June 1999.

IEEE 802.3ab
IEEE 802.3ab describes the specifications for running Gigabit Ethernet over unshielded twisted-
pair copper cabling. 1000BASE-T provides 1-Gbps throughput via four pairs of Category 5
unshielded twisted-pair (UTP) cable (250 Mbps per wire pair). (Note that all eight wires
are used, as opposed to 10BASE-T and 100BASE-T.) Cabling distances for such an instal-
lation cannot exceed 100 meters.
1439_CCNP_3.book Page 704 Wednesday, October 27, 2004 9:54 AM

704 Appendix B: Gigabit Ethernet and 10 Gigabit Ethernet Standards and Operation

Before you upgrade to Gigabit Ethernet, you should test existing Category 5 cable for far-end
crosstalk and return loss. If the cable fails the test, the ANSI/TIA/EIA TSB-95 standard details
options for correcting the problems. For new installations, Category 5e cable is recommended.
The standard supports both half-duplex and full-duplex operation, but full-duplex implemen-
tations are far more common. The carrier sense multiple access collision detect (CSMA/CD)
access method is used when Gigabit Ethernet is operating in half-duplex mode. In full-duplex
mode, CSMA/CD is out of the picture, but flow-control mechanisms are used to handle
buffering.
Gigabit Ethernet over Category 5 cable is presently the most common medium for horizontal
cabling in ceilings and floors. However, as with Fast Ethernet, fiber-optic cabling is the
medium of choice between buildings and between floors of a building.
1000BASE-T can be deployed in three parts of a network:
■ Switch uplinks—1000BASE-T provides high-bandwidth connectivity from desktop
switches to the next point of aggregation. With such uplinks, switches can be linked to
servers and other resources at gigabit speeds. These connections can substantially
relieve network congestion, improving access to high-bandwidth applications and data.
■ Server connectivity—1000BASE-T links can be used to connect high-performance
servers to the switch. This use dramatically improves traffic flow. Moreover, the price
of 1000BASE-T network interface cards has been falling at the same time availability
has been increasing.
■ Desktop connectivity—As desktop network interface cards become available, users
will begin implementing 1000BASE-T at the desktop. At first, only power users will
require such performance on the desktop. However, over time, 1000BASE-T is expected
to migrate more to the desktop as prices continue to decrease.

IEEE 802.3z
The Gigabit interface converter (GBIC) allows network engineers to configure each gigabit
port on a port-by-port basis for short wavelength (SX), long wavelength (LX), and long-haul
(LH) interfaces. Figure B-1 shows the various distances allowed for the 1000BASE-SX and
1000BASE-LX Gigabit Ethernet standards. Vendor-specific LH GBICs extend the single-mode
fiber distance from the standard 5 km up to 70 km. The LH option is a value-add; although
it’s not part of the 802.3z standard, LH allows switch vendors to build a single physical
switch or switch module that the customer can configure for the required laser/fiber topology.
The 802.3z specification calls for media support of multimode fiber-optic cable, single-mode
fiber-optic cable, and a special balanced shielded 150-ohm copper cable. The current connector
for Gigabit Ethernet is the SC connector for both single-mode and multimode fiber.
1439_CCNP_3.book Page 705 Wednesday, October 27, 2004 9:54 AM

10 Gigabit Ethernet 705

The signaling rate for Gigabit Ethernet is 1.25 Gbps. With the 8B/10B encoding scheme, data
transmission amounts to 1.0 Gbps.

10 Gigabit Ethernet
10 Gigabit Ethernet was formally ratified as an IEEE 802.3 Ethernet standard in June 2002.
This technology is the next step in scaling the performance and functionality of enterprise
and service provider networks, because it combines multigigabit bandwidth and intelligent
services to achieve scaled, intelligent, multigigabit networks with network links that range
in speed from 10 Mbps to 10,000 Mbps. Since March 1999, the Ethernet industry has been
working to increase the speed of Ethernet from 1 Gbps to 10 Gbps. This technology is very
significant because not only will Ethernet run at 10 Gbps and serve as a LAN connection, but
it also will work in metropolitan-area networks (MANs) and WANs. With 10 Gigabit Ethernet,
network managers will be able to build LANs, MANs, and WANs using Ethernet as the
end-to-end Layer 2 transport.
10 Gigabit Ethernet is a full-duplex technology that targets the LAN, MAN, and WAN application
spaces. Prestandard 10 Gigabit Ethernet products entered the market in 2001. 10 Gigabit
Ethernet supports multimode and single-mode fiber-optic installations (note the fiber-only
options). Coupled with devices supporting wave division multiplexing, 10 Gigabit Ethernet
extends Ethernet to the WAN, allowing a common technology to run over both private and
public networks. LAN applications support distances of up to 40 km with single-mode fiber,
connecting multiple campus locations within a 40-km range (see Figure B-2).

Figure B-2 10 Gigabit in the LAN Permits Links Ranging Up to 40 km

Campus A Campus B

To 40 km

10 GbE
SM Fiber

10 GbE
100 to 300 m,
MM Fiber

• Cost-Effective Bandwidth for the LAN, Switch-to-Switch


• Used to Aggregate Multiple Gigabit Ethernet Segments
• 10 Gigabit EtherChannel Will Enable 20 to 80 Gbps (Future)
1439_CCNP_3.book Page 706 Wednesday, October 27, 2004 9:54 AM

706 Appendix B: Gigabit Ethernet and 10 Gigabit Ethernet Standards and Operation

Positioned as a high-speed technology for networking applications in LANs, MANs, and


WANs, 10 Gigabit Ethernet will provide very high bandwidth with simplicity and relatively
low cost. In LAN applications, 10 Gigabit Ethernet will let network managers scale their
packet-based networks from 10 Mbps to 10,000 Mbps and thereby leverage their investments
in Ethernet as they increase their networks’ performance. In MAN and WAN applications,
10 Gigabit Ethernet will allow Internet service providers (ISPs) and network service providers
(NSPs) to create very high-speed links at very low cost between colocated carrier-class switches
and routers.

10 Gigabit Ethernet Standards


In the Open System Interconnection (OSI) model, Ethernet is fundamentally a Layer 2 proto-
col. 10 Gigabit Ethernet uses the IEEE 802.3 Ethernet Media Access Control (MAC) proto-
col, the IEEE 802.3 Ethernet frame format, and the minimum and maximum IEEE 802.3
frame size. Just as 1000BASE-X and 1000BASE-T (Gigabit Ethernet) remained true to the
Ethernet model, 10 Gigabit Ethernet continues the natural evolution of Ethernet in speed and
distance. Because it is a full-duplex-only and fiber-only technology, 10 Gigabit Ethernet does
not need the carrier sense multiple access collision detect (CSMA/CD) access method that
defines slower, half-duplex Ethernet technologies. In every other respect, 10 Gigabit Ethernet
remains true to the original Ethernet model. An Ethernet physical layer device, which corre-
sponds to Layer 1 of the OSI model, connects the medium, optical or copper, to the MAC
layer, which corresponds to OSI Layer 2. The Ethernet architecture further divides Layer 1
into a physical medium dependent (PMD) and a physical coding sublayer (PCS). An optical
transceiver is an example of a PMD. The PCS is made up of coding algorithms and a serial-
izer. It often implements multiplexing functions.
The 802.3ae specification defines two physical layer types, such as the LAN and WAN phys-
ical sublayers (PHYs), as shown in Figure B-3. The WAN PHY has an extended feature set
added to the functions of a LAN PHY. These PHYs are solely distinguished by the PCS.
The WAN PHY differs from the LAN PHY by the inclusion of a simplified Synchronous
Optical Network (SONET) framer. Because SONET OC-192 is within a few percent of 10 Gbps,
it is simple to implement a MAC to be able to operate with a LAN PHY at 10 Gbps or a WAN
PHY at the SONET OC-192 payload rate. To enable low-cost WAN PHY implementations,
the IEEE 802.3ae committee specifically rejected conformance to SONET jitter, stratum
clock, and other SONET optical specifications. Therefore, the WAN interface sublayer (WIS)
does not render a 10 Gigabit Ethernet WAN PHY compliant with either SONET or Synchronous
Digital Hierarchy (SDH) at any rate or format.
1439_CCNP_3.book Page 707 Wednesday, October 27, 2004 9:54 AM

10 Gigabit Ethernet 707

Figure B-3 IEEE 802.3ae Specifies a LAN and WAN PHY

IEEE 802.3 Media Access Control (MAC)


Full Duplex

10 Gigabit Media Independent Interface (XGMII) or


10 Gigabit Attachment Unit Interface (XAUI)

CWDM Serial Serial


LAN PHY LAN PHY WAN PHY
(8 B/10 B) (64 B/66 B) (64 B/66 B + WIS)

CWDM CWDM CWDM CWDM CWDM CWDM CWDM


PMD PMD PMD PMD PMD PMD PMD
1310 nm 850 nm 1310 nm 1550 nm 850 nm 1310 nm 1550 nm

The LAN PHY is the most cost-effective solution to support the existing 10 Gigabit Ethernet
applications across LAN and MAN distances on dark fiber and dark wavelengths. However,
it lacks the ability to speak the same language as synchronous time-division multiplexing
(TDM) gear, most prevalent in the WAN environment. The WAN PHY can be used to connect
Ethernet-based networks to the existing SONET/SDH TDM and dense wavelength division
multiplexing (DWDM) infrastructure and support lit wavelengths and lit fiber over WAN
distances.
It is expected that the LAN PHY will also be used in pure optical switching environments
extending over long-haul distances. This is possible because, by using optical equipment that
incorporates the capability to transparently carry higher-level technologies such as 10 Gigabit
Ethernet, ATM, SONET, SDH, and so on, LAN and TDM services will seamlessly converge
into a single optical infrastructure. This infrastructure will provide a Layer 1 transport across
MAN/WAN distances and will offer carrier-grade reliability while being technology-agnostic.
Therefore, the importance of the WAN PHY for long-haul applications will also diminish.
When dark wavelengths are available, 10 Gigabit Ethernet can be transmitted directly across
the optical infrastructure, reaching distances of 70 to 100 km!
1439_CCNP_3.book Page 708 Monday, November 1, 2004 11:16 AM
1439_CCNP_3.book Page 709 Wednesday, October 27, 2004 9:54 AM

Appendix C

Using the Catalyst Operating


System
Cisco routers run on Cisco IOS software. The command-line interface (CLI) embedded in Cisco
IOS software is by now quite familiar to you. However, you might not be as familiar with the
Catalyst operating system.
There are two major Catalyst switch operating systems. One of these is called Catalyst OS, CatOS,
Catalyst set command-based OS, or set-based OS. The CatOS is distinguished by its reliance on
set commands.
The other major Catalyst operating system is the one used on switches, such as the Catalyst 2950
and 3550. This is an IOS-like operating system, a hybrid OS that evolved from Cisco’s acquisition of
Kalpana in 1994. This Catalyst switch operating system is normally referred to as command-
based or IOS-based. In fact, executing a show version command on a Catalyst 2950 switch
reveals “Cisco Internetwork Operating System software” in the first line of output. The IOS-
based Catalyst operating system is very similar to the router IOS to which you’re accustomed.
Catalyst 6500 series switches have an optional “native IOS.” It is a single Cisco IOS image that
simultaneously controls the Layer 2, 3, and 4 configuration. Native IOS is also called Catalyst
IOS, Cat IOS, or Supervisor IOS. In this case, the Supervisor module and the Multilayer Switch
Feature Card (MSFC) both run a single bundled Cisco IOS image. The Catalyst 6500 Supervisor
Engine 720 has an integrated Policy Feature Card 3 (PFC3) and a Multilayer Switch Feature Card 3
(MSFC3), and all can be managed with a single bundled IOS image. The Supervisor Engine III
and IV for Catalyst 4500 series switches also use an integrated native IOS image. The IOS com-
mands used in these hardware combinations are similar, if not identical, to the IOS switch commands
used throughout this book.
1439_CCNP_3.book Page 710 Wednesday, October 27, 2004 9:54 AM

710 Appendix C: Using the Catalyst Operating System

Companies over the years have deployed Catalyst switches, such as the 4000, 5000, and 6000
family switches, using the CatOS. Many of these companies opt not to migrate to the IOS-based
alternatives to the CatOS, so Cisco continues to support CatOS options for these switches.
However, the trend is clearly in the direction of an integrated, strictly IOS-based solution for
Cisco routers and switches.
In this appendix, you’ll learn the following basic system administration tasks for Catalyst
switches using the CatOS:
■ Accessing the switch CLI
■ Configuring idle timeouts
■ Configuring passwords
■ Recovering passwords
■ Erasing configurations
■ Saving configurations
■ Naming the switch
■ Configuring Telnet access
■ Setting the port speed and duplex
■ Setting port/interface descriptors
■ Using command history options
■ Using help features
■ Using the ping command
■ Executing TFTP downloads
■ Using basic show commands

Preparing to Access the Switch


Before you can begin configuring your switch, you’ll need to access the switch’s operating
system using a console connection, a modem connection, or a Telnet session. You also need a
terminal emulation program to access the command line for the switch OS.

Console Access
When your switch is right out of the box, the first step of configuring it is connecting to it via
the console port from a workstation. Your switch documentation details which connectors and
cables to use. Your switch will arrive with the connectors and cables you need for console
access. Should you need to terminate cables or adapters for console access, the pinouts for
each Catalyst switch can be found at http://www.Cisco.com.
1439_CCNP_3.book Page 711 Wednesday, October 27, 2004 9:54 AM

Preparing to Access the Switch 711

For example, to console in to a Supervisor Engine on a Catalyst 4000/5000/6000 switch from


a PC, use an RJ-45-to-RJ-45 rollover cable and the DB-9-to-RJ-45 serial adapter supplied
with the switch, and follow these steps (as you would with most Cisco routers):
Step 1 Connect one end of the rollover cable to the console port.
Step 2 Attach the supplied DB-9-to-RJ-45 serial adapter (labeled “Terminal”) to a
“Comm” port on the PC.
Step 3 Attach the other end of the rollover cable to the RJ-45 port on the serial
adapter.
Connecting via the console port gives you direct physical access to the switch’s operating
system, whether it be a fixed-chassis switch or a switch chassis with 13 modules. On chassis
switches, you often have the option of consoling directly into various modules populating the
chassis. Normally, though, you’ll console into the Supervisor module on these switches and
access modules indirectly via the switch’s backplane.

Terminal Emulation
Many applications, such as Tera Term, HyperTerminal (shown in Figure C-1), and SecureCRT,
include terminal emulation programs that can be used for console access to a Catalyst switch.
These applications typically provide other access options, such as Telnet (TCP port 23) and
Secure Shell (TCP port 22). In addition, these applications give you a wide range of fine-tuning
options, such as scrollback buffer size, function keys, scripting, window size, and line delay.

Figure C-1 HyperTerminal Is a Terminal Emulation Application That Can Be Used for Console
Access to a Catalyst Switch
1439_CCNP_3.book Page 712 Wednesday, October 27, 2004 9:54 AM

712 Appendix C: Using the Catalyst Operating System

Fundamentals of Switch Configuration


As soon as you have access to the switch’s operating system, you need to understand how to
navigate through the system and perform basic tasks, just as you would on a PC.

Entering the Switch and Changing Modes


On CatOS, the CLI supports two modes of operation:
■ Normal (also called login or user mode)
■ Privileged (also called enable mode)
Both modes are password-protected. Use normal-mode commands for system monitoring,
similar to a Cisco router’s user EXEC mode. Normal mode allows you to view most switch
parameters, but you’re unable to make configuration changes. Privileged-mode commands
are used to change the system configuration, unlike on a Cisco router, where you need to
enter global configuration mode to make system changes.
When you first connect to the switch (with the proper physical media and a terminal emula-
tion program), you see the following prompt:
Enter password:

On a new switch, the normal-mode password is null. If you are connecting to a new switch,
press Enter at the prompt. Otherwise, enter the normal-mode password for the switch.
After you enter the correct password
Enter Password: normal_mode_password

you see the following user-level command-line prompt:


Console>

To disconnect from the switch CLI, enter the exit command:


Console> exit
Session Disconnected...

Cisco Systems, Inc. Console Fri Dec 27 2002, 02:47:02

Many commands (such as commands that modify the configuration) can be entered only in
privileged mode. To enter privileged command mode from normal mode, enter the enable
command. On a new switch, the privileged-mode password is null. If you’re connecting to a
new switch, press Enter at the Enter password prompt. Otherwise, enter the privileged-mode
password for the switch as follows:
Console> enable

Enter password: privileged_mode_password


Console> (enable)
1439_CCNP_3.book Page 713 Wednesday, October 27, 2004 9:54 AM

Fundamentals of Switch Configuration 713

Note the change in the prompt for privileged mode. To exit privileged mode and return to nor-
mal mode, enter the disable command.
As with a router, switch commands are additive in that making a configuration change does
not completely overwrite the existing configuration.

Command-Line Processing and Editing


Switch commands are not case-sensitive. You can abbreviate commands and parameters as
long as they contain enough letters to be different from any other currently available com-
mands or parameters. You can scroll through the last 20 commands stored in the history
buffer and enter or edit the command at the prompt. Table C-1 lists command-line processing
and editing keystroke shortcuts.

Table C-1 Command-Line Processing and Editing

Keystroke Function

Ctrl-A Jumps to the first character of the command line.

Ctrl-B or the left arrow key Moves the cursor back one character.

Ctrl-C Escapes and terminates prompts and tasks.

Ctrl-D Deletes the character at the cursor.

Ctrl-E Jumps to the end of the current command line.

Ctrl-F or the right arrow key Moves the cursor forward one character.

Ctrl-K Deletes from the cursor to the end of the command line.

Ctrl-L; Ctrl-R Repeats the current command line on a new line.


Ctrl-N or the down arrow key Enters the next command line in the history buffer.

Ctrl-P or the up arrow key Enters the previous command line in the history buffer.

Ctrl-U; Ctrl-X Deletes from the cursor to the beginning of the command
line.

Ctrl-W Deletes the last word typed.

Esc B Moves the cursor back one word.

Esc D Deletes from the cursor to the end of the word.

Esc F Moves the cursor forward one word.

Delete key or Backspace key Erases a mistake when you enter a command. Reenter the
command after pressing this key.
1439_CCNP_3.book Page 714 Wednesday, October 27, 2004 9:54 AM

714 Appendix C: Using the Catalyst Operating System

Just as with the Cisco router IOS, if you cannot remember a complete command name, press
the Tab key to allow the system to complete a partial entry. If you enter a set of characters
that could indicate more than one command, the system beeps to indicate an error. Enter a
question mark (?) to obtain a list of commands that begin with that set of characters. Do not
leave a space between the last letter and the question mark. For example, suppose that three
commands in privileged mode start with co. To see what they are, enter co? at the privileged
prompt. The system displays all commands (and their descriptions) that begin with co. Note
that you don’t need to press the Enter key after the question mark.
When the output is longer than the terminal screen can display, a --More-- prompt is displayed at
the bottom of the screen. Press the Enter key to see the next line, or press the Spacebar
to see the next screen of output. If you enter /text and press the Enter key at the --More--
prompt, the display starts two lines above the line containing the text string. If the text string
is not found, Pattern Not Found is displayed. You can also enter n at the --More-- prompt to
search for the last entered text string.

Command History
Several shortcuts are available for repeating and/or editing previously entered commands.
Table C-2 lists the various combinations.

Table C-2 Command History

Command Function

To repeat recent commands:

!! Repeats the most recent command.

!-nn Repeats the nnth most recent command.


!n Repeats the command n.

!aaa Repeats the command beginning with string aaa.

!?aaa Repeats the command containing the string aaa.


To modify and repeat the most recent command:

^aaa^bbb Replaces the string aaa with the string bbb in the most recent
command.
1439_CCNP_3.book Page 715 Wednesday, October 27, 2004 9:54 AM

Fundamentals of Switch Configuration 715

Table C-2 Command History (Continued)

Command Function

To add a string to the end of a previous command and repeat it:

!!aaa Adds the string aaa to the end of the most recent command.

!n aaa Adds the string aaa to the end of command n.

!aaa bbb Adds the string bbb to the end of the command beginning with
string aaa.

!?aaa bbb Adds the string bbb to the end of the command containing
string aaa.

Help Features
To see a list of commands and command categories, enter help in normal or privileged mode.
Also, you can get context-sensitive help (usage and syntax information) for individual commands
by appending help to any specific command (as opposed to a Cisco router, where output is
displayed on a parameter-by-parameter basis, with no context-sensitive help). If you enter a
command using the wrong number of arguments or inappropriate arguments, usage and syn-
tax information for that command is displayed. Additionally, appending help to a command
category displays a list of commands in that category. Example C-1 displays these options
(note that the output of clear help is truncated).

Example C-1 The Syntax of the help Command Differs from That of IOS

Console> (enable) help


Commands:
----------------------------------------------------------------------------
cd Set default flash device
clear Clear, use 'clear help' for more info
configure Configure system from network
copy Copy files between TFTP/RCP/module/flash devices
delete Delete a file on flash device
dir Show list of files on flash device
disable Disable privileged mode
continues
1439_CCNP_3.book Page 716 Wednesday, October 27, 2004 9:54 AM

716 Appendix C: Using the Catalyst Operating System

Example C-1 The Syntax of the help Command Differs from That of IOS (Continued)

disconnect Disconnect user session


download Download code to a processor
enable Enable privileged mode
format Format a flash device
help Show this help screen
history Show contents of history substitution buffer
l2trace Layer2 trace between hosts
ping Send echo packets to hosts
pwd Show default flash device
quit Exit from the Admin session
reconfirm Reconfirm VMPS
reset Reset system or module
session Tunnel to ATM or Router module
set Set commands, use 'set help' for more info
show Show commands, use 'show help' for more info
slip Attach/detach Serial Line IP interface
squeeze Reclaim space used by deleted files
telnet Telnet to a remote host
test Test command, use 'test help' for more info
traceroute Trace the route to a host
undelete Undelete a file on flash device
upload Upload code from a processor
verify Verify checksum of file on flash device
wait Wait for x seconds
whichboot Which file booted
write Write system configuration to terminal/network

Console> (enable) copy help


Usage: copy file-id <tftp | rcp | flash | file-id | config>
copy <tftp | rcp > <flash | file-id | config>
copy flash <tftp | rcp | file-id | config>
copy config <flash | file-id | tftp | rcp> [all]
file-id has the format of [[m/]device:][filename]
(example of file-id : bootflash:new_image, 1/bootflash:old_image)

Console> (enable) clear help


1439_CCNP_3.book Page 717 Wednesday, October 27, 2004 9:54 AM

Fundamentals of Switch Configuration 717

Example C-1 The Syntax of the help Command Differs from That of IOS (Continued)

Clear commands:
----------------------------------------------------------------------------
clear alias Clear aliases of commands
clear arp Clear ARP table entries
clear banner Clear Message Of The Day banner
clear boot Clear booting environment variable
clear cam Clear CAM table entries
clear cgmp Clear CGMP statistics
clear channel Clear PagP statistical information
clear config Clear configuration and reset system
clear counters Clear MAC and Port counters
clear dot1x Clear Dot1x feature
clear gmrp Clear GMRP statistics
clear gvrp Clear GVRP statistics
clear igmp Clear IGMP filter
clear ip Clear IP, use 'clear ip help' for more info
clear kerberos Clear Kerberos configuration information
clear key Clear config-key string
clear lacp-channel clear LACP statistical information
clear localuser Clear localuser record
clear log Clear log information
clear logging Clear system logging information
clear multicast Clear multicast router port
clear netstat Clear network statistics
clear ntp Clear NTP servers and timezone
clear port Clear port features
clear pvlan Clear Private Vlan Mappings
clear qos Clear QoS features
clear radius Clear radius information
clear rcp Clear RCP information for other copy
clear snmp Clear SNMP trap receiver address
clear spantree Clear spantree parameters
clear tacacs Clear TACACS server host/key
clear timezone Clear timezone
clear top Clear TopN report
continues
1439_CCNP_3.book Page 718 Wednesday, October 27, 2004 9:54 AM

718 Appendix C: Using the Catalyst Operating System

Example C-1 The Syntax of the help Command Differs from That of IOS (Continued)

clear trunk Clear trunk ports


clear vlan Clear VLAN information
clear vmps Clear VMPS information
clear vtp Clear VTP statistics
Console> (enable)

Notice that when the console displays help, it returns the command line with a blank line
(where the command copy help was entered in Example C-1). The command string you
entered so far is not displayed for you as it is on a router.

Erasing and Saving the Configuration


On a Catalyst CatOS-based switch, as with a Cisco router, commands are additive. This means
that adding configuration statements to an existing file does not completely overwrite the
existing configuration. To ensure that a new configuration completely overwrites an existing
configuration, enter the clear config all command. When you clear the configuration using
the clear config all command, the factory default switch configuration is restored. The all
keyword specifies clearing of all modules and system configuration information, including
the IP address (so if you are accessing the switch via Telnet, you lose your connection to the
switch). With the all keyword, all ports are restored to virtual LAN (VLAN) 1, VLAN Trunk-
ing Protocol (VTP) is not configured, and all spanning-tree parameters revert to their default
values.
Example C-2 shows how to clear the configuration for the entire switch.

Example C-2 Restoring the Default Configuration on a CatOS Switch

Console> (enable) clear config all


This command will clear all configuration in NVRAM.
This command will cause ifIndex to be reassigned on the next system startup.
Do you want to continue (y/n) [n]? y
........
.............................

System configuration cleared.


Console> (enable)
1439_CCNP_3.book Page 719 Wednesday, October 27, 2004 9:54 AM

Fundamentals of Switch Configuration 719

To clear the configuration on an individual module, use the clear config mod_num command
in privileged mode. Example C-3 shows how to clear the configuration for module 2.

Example C-3 Erasing the Configuration for Module 2 in a CatOS Switch

Console> (enable) clear config 2


This command will clear module 2 configuration.
Do you want to continue (y/n) [n]? y
.............................
Module 2 configuration cleared.
Console> (enable)

The clear config all command affects only modules that are directly configured from the
Supervisor module. To clear the configurations on the router modules, you need to access the
modules with the session module_number command. This command performs the equivalent
of an internal Telnet to the module so that you can make configuration changes. To display
which slot the router module is in, use the show module command. The router modules on a
switch use Cisco IOS commands to change, save, and clear configurations.
Configuring the switch through the console and via Telnet allows you to save commands in
real-time. Unlike a router, the switch immediately stores commands in nonvolatile random-
access memory (NVRAM). Any command entered into a Catalyst switch is immediately
stored and remembered, even through a power cycle. This presents a challenge when you
attempt to reverse a series of commands. On a router, you can reverse a series of commands
with reload, as long as you didn’t write the running configuration into NVRAM. You’ll find
that many times the most challenging tasks with CatOS involve removing configured items.

Passwords
One of the first tasks you should perform when configuring a networking device is to secure it NOTE
against unauthorized access. The simplest form of security in a campus network is to limit The default login and
enable passwords are
access to the switches in the switch block with passwords. By setting passwords, you can
null on CatOS. Just
limit the level of access or completely exclude a user from logging on to an access, distribu- press Enter at the
tion, or core layer switch. prompt.

You can apply two types of passwords to your devices. The login password requires that you
verify authorization before accessing any line, including the console. The enable password
requires authentication before you can set or change the system operating parameters.
1439_CCNP_3.book Page 720 Wednesday, October 27, 2004 9:54 AM

720 Appendix C: Using the Catalyst Operating System

To set the normal (login) mode password on a CatOS switch, use the set password command.
You’re prompted to enter the old password and the new password and to reenter the new pass-
word. Passwords are case-sensitive and might be 0 to 30 characters in length, including
spaces. You do not see any output as you enter the passwords, as shown in Example C-4.

Example C-4 Changing the CatOS Login Password

Console> (enable) set password


Enter old password:
Enter new password:
Retype new password:
Password changed.
Console> (enable)

Example C-5 demonstrates how to change the privileged (enable) mode password on the
switch using the command set enablepass.

Example C-5 Changing the CatOS Enable Password

Console> (enable) set enablepass


Enter old password:
Enter new password:
Retype new password:
Password changed.
Console> (enable)

Example C-6 displays a portion of the CatOS show config output. This command is used to
display the nondefault system and module configuration. You can see the login and enable
passwords displayed as encrypted text.

Example C-6 The show config Output Is Extremely Lengthy. The Login and Enable Passwords Appear as
Encrypted Text.

Console> (enable) show config


This command shows non-default configurations only.
Use 'show config all' to show both default and non-default configurations.
************
******************
1439_CCNP_3.book Page 721 Wednesday, October 27, 2004 9:54 AM

Fundamentals of Switch Configuration 721

Example C-6 The show config Output Is Extremely Lengthy. The Login and Enable Passwords Appear as
Encrypted Text. (Continued)

********************

**

begin
!
# ***** NON-DEFAULT CONFIGURATION *****
!
!
#time : Fri Dec 21 2001, 15 :33 :14
!
#version 6.2(1)
!
!
#system web interface version(s)
set password $2$FxA/$KIPORCd/9ocXmtxpXQaFA/
set enablepass $2$vgI.$.OXPfwpUqD5QvC9FtCWPL1
!

Password Recovery
Each networking device has its own procedure for recovering passwords. For Cisco devices,
the procedures are conveniently organized by platform in the article “Password Recovery
Procedures” (Document ID: 6130) at http://www.cisco.com/warp/public/474/.
As demonstrated in the following password recovery process, an attacker simply needs to
reboot the Catalyst switch and to access the console to get into privileged mode. When in
privileged mode, the attacker can make any changes desired. It is extremely important that
you maintain physical security of your equipment. It really does pay to keep wiring closets
secured and console access restricted.
1439_CCNP_3.book Page 722 Wednesday, October 27, 2004 9:54 AM

722 Appendix C: Using the Catalyst Operating System

The CatOS password recovery procedure is the easiest to perform of all Cisco devices:
Step 1 Connect to the switch with the appropriate console cable, adapter, terminal
emulation program, and terminal settings.
Step 2 Turn the switch off and on.
Step 3 Within 30 seconds of turning on the switch, perform the following sequence:
a. Press Enter at the password prompt to enter a null password.
b. Enter enable at the prompt to enter enable mode.
c. Press Enter at the password prompt to enter a null password.
d. Change the password using the set password command or the set
enablepass command.
e. Press Enter at the prompt to enter the old password.

Setting System Name, Contact, and Location


The system name on a CatOS switch is similar to the host name on a Cisco router. It can
be manually configured or assigned via Domain Name System (DNS). To manually set the
system name, use the command set system name name_string. When you set the system
name, the first 20 characters of the name are used as the system prompt. You can override this
with the set prompt prompt_string command. To clear the system name, use the command
set system name with no arguments.
You can specify the contact name and location to help you with resource management tasks.
The system contact and location are set with the commands set system contact and set system
location. Example C-7 demonstrates the name, contact, and location system commands.

Example C-7 Setting the System Name, Contact, and Location

Console> (enable) set system name Cat6506


System name set.
Cat6506> (enable) set system name
System name cleared.
Console> (enable) set system contact [email protected]
System contact set.
Console> (enable) set system location Newtown
System location set.

The system name, contact, and location can be viewed with the show system command.
1439_CCNP_3.book Page 723 Wednesday, October 27, 2004 9:54 AM

Fundamentals of Switch Configuration 723

Remote Access
Before you can Telnet to, ping, or globally manage a switch, you need to assign the switch an
IP address, associate the switch with the management VLAN, and define a default gateway.
Although many LAN switches are primarily Layer 2 devices, these switches maintain an IP
stack for administrative purposes. Assigning an IP address to the switch associates that switch
with the management VLAN, provided that the subnet portion of the switch IP address matches
the subnet number of the management VLAN.
The in-band (sc0) management interface on the Supervisor Engines of Catalyst 4500, 5500,
and 6500 series switches is connected to the switching fabric and participates in all the func-
tions of a normal switch port, such as spanning tree, Cisco Discovery Protocol (CDP), and
VLAN membership. When you configure the IP address, subnet mask, broadcast address,
and VLAN membership of the sc0 interface, you can access the switch through Telnet or
Simple Network Management Protocol (SNMP).
All IP traffic generated by the switch (for example, a Telnet session opened from the switch
to a host) is forwarded according to the entries in the switch IP routing table. For network
communication to occur, you must configure at least one default gateway for the sc0 inter-
face. The switch IP routing table is used to forward traffic originating on the switch only, not
to forward traffic sent by devices connected to the switch.
The switch can be configured to obtain its IP configuration automatically via Dynamic Host
Configuration Protocol (DHCP) or Reverse Address Resolution Protocol (RARP), but the
focus here is on manual configuration.
The default IP settings are as follows for the sc0 interface:
■ The IP address, subnet mask, and broadcast address are 0.0.0.0.
■ sc0 is assigned to VLAN 1.
■ The default gateway address defaults to 0.0.0.0 with a metric of 0.
To assign an IP address to the sc0 interface, use the command set interface sc0 [ip_addr[/netmask]
[broadcast]]. You can specify the subnet mask (netmask) using the number of subnet bits or
using the subnet mask in dotted-decimal format. Example C-8 illustrates these two options.

Example C-8 Setting the IP Address and Subnet Mask for the Management Interface

Console> (enable) set interface sc0 128.1.2.3/24


Interface sc0 IP address and netmask set.

continues
1439_CCNP_3.book Page 724 Wednesday, October 27, 2004 9:54 AM

724 Appendix C: Using the Catalyst Operating System

Example C-8 Setting the IP Address and Subnet Mask for the Management Interface (Continued)

Console> (enable) show interface


sl0: flags=50<DOWN,POINTOPOINT,RUNNING>
slip 0.0.0.0 dest 0.0.0.0
sc0: flags=63<UP,BROADCAST,RUNNING>
vlan 1 inet 128.1.2.3 netmask 255.255.255.0 broadcast 128.1.2.255
me1: flags=62<DOWN,BROADCAST,RUNNING>
inet 0.0.0.0 netmask 0.0.0.0 broadcast 0.0.0.0

Console> (enable) set interface sc0 128.1.2.3/255.255.255.0


Interface sc0 IP address and netmask set.

Console> (enable) show interface


sl0: flags=50<DOWN,POINTOPOINT,RUNNING>
slip 0.0.0.0 dest 0.0.0.0
sc0: flags=63<UP,BROADCAST,RUNNING>
vlan 1 inet 128.1.2.3 netmask 255.255.255.0 broadcast 128.1.2.255
me1: flags=62<DOWN,BROADCAST,RUNNING>
inet 0.0.0.0 netmask 0.0.0.0 broadcast 0.0.0.0

NOTE To associate the in-band logical interface to a specific VLAN, enter the set interface sc0
To assign ports 2/3, vlan command. If you do not specify a VLAN, the system automatically defaults to VLAN1
2/4, 2/5, and 5/7 to
and the management VLAN. Example C-9 shows how to assign interface sc0 to VLAN 1 and
VLAN 3, for example,
use the command administratively bring it up.
set vlan 3 2/3-5, 5/7.
Example C-9 Assigning the Management Interface to a VLAN

Console> (enable) set interface sc0 1


Interface sc0 vlan set.
Console> (enable) set interface sc0 up
Interface sc0 administratively up.

Finally, you need to configure the default gateway. The Supervisor Engine sends IP packets
destined for other IP subnets to the default gateway (a router interface in the same subnet as
the switch IP address). The switch does not use the IP routing table to forward traffic from
connected devices, only IP traffic generated by the switch itself (for example, Telnet, Trivial
File Transfer Protocol [TFTP], and ping).
1439_CCNP_3.book Page 725 Wednesday, October 27, 2004 9:54 AM

Fundamentals of Switch Configuration 725

You can define up to three default IP gateways. Use the primary keyword to make a gateway
the primary gateway. If you do not specify a primary default gateway, the first gateway con-
figured is the primary gateway. If more than one gateway is designated as primary, the last
primary gateway configured is the primary default gateway.
The switch sends all off-network IP traffic to the primary default gateway. If connectivity to
the primary gateway is lost, the switch attempts to use the backup gateways in the order they
were configured. The switch sends periodic ping messages to determine whether each default
gateway is up or down. If connectivity to the primary gateway is restored, the switch resumes
sending traffic to the primary.
To specify one or more default gateways, use the set ip route default gateway [metric]
[primary] command. To remove default gateway entries, use the clear ip route default
gateway command, or use clear ip route all to remove all default gateways and static routes.
Example C-10 provides an example of configuring and removing default gateways.

Example C-10 Setting and Removing a Default Gateway

Console> (enable) set ip route default 128.1.2.1 primary


Route added.
Console> (enable) set ip route default 128.1.2.2
Route added.
Console> (enable) show ip route
Fragmentation Redirect Unreachable
------------- -------- -----------
enabled enabled enabled

The primary gateway: 128.1.2.1


Destination Gateway RouteMask Flags Use Interface
--------------- --------------- ---------- ----- -------- ---------
default 128.1.2.2 0x0 G 0 sc0
default 128.1.2.1 0x0 UG 0 sc0
128.1.2.0 128.1.2.3 0xffffff00 U 14 sc0

Console> (enable) clear ip route default 128.1.2.1


Route deleted.
Console> (enable) show ip route
Fragmentation Redirect Unreachable
------------- -------- -----------
continues
1439_CCNP_3.book Page 726 Wednesday, October 27, 2004 9:54 AM

726 Appendix C: Using the Catalyst Operating System

Example C-10 Setting and Removing a Default Gateway (Continued)

enabled enabled enabled

The primary gateway: 128.1.2.2


Destination Gateway RouteMask Flags Use Interface
--------------- --------------- ---------- ----- -------- ---------
default 128.1.2.2 0x0 UG 0 sc0
128.1.2.0 128.1.2.3 0xffffff00 U 332 sc0

After the switch is configured for IP, it can communicate with other nodes on the network
(beyond simply switching traffic). To test connectivity to remote hosts, use the ping destination
ip address command. The ping command returns one of the following responses:
■ Success rate is 100 percent or ip address is alive—This response occurs in 1 to
10 seconds, depending on network traffic and the number of Internet Control Message
Protocol (ICMP) packets sent.
■ Destination does not respond—No answer message is returned if the host does not
respond.
■ Unknown host—This response occurs if the targeted host does not exist.
■ Destination unreachable—This response occurs if the default gateway cannot reach
the specified network.
■ Network or host unreachable—This response occurs if there is no entry in the route
table for the host or network.
Finally, because the focus of this discussion is remote access, it’s useful to be able to adjust
idle timeouts. The idle timeout specifies how long the connection stays active without any
keystrokes taking place. The idea is that, if you forget to log out and leave your terminal
unattended, the idle timeout prevents someone from gaining unauthorized access to the switch
by using the terminal. Although this feature’s default setting is 5 minutes, you can alter it with
the set logout number of minutes command. If you use the 0 argument (set logout 0), sessions
are not automatically logged out.

Loading Images to Flash


One of the more common administrative tasks is to load images to Macromedia Flash memory.
The procedure is similar for all Cisco network devices. The idea is to set up a TFTP server
and download a new image to the device via Ethernet using the IP address configuration of
the appropriate management interface.
1439_CCNP_3.book Page 727 Wednesday, October 27, 2004 9:54 AM

Fundamentals of Switch Configuration 727

The Supervisor Engine implements a file system that can hold several images. Supervisors have
at least a Flash device named bootflash:. Depending on the number of PCMCIA slots on the
Supervisor, you can also have a slot0: and a slot1: Flash device available. Most basic operations
such as listing, copying, and deleting files on these devices are available, with commands simi-
lar in name and syntax to DOS commands. Here’s a list of common commands:
■ Formatting Flash—format device:
■ Listing files on Flash—dir [device:] [all]
■ Changing the default Flash device—cd device
■ Copying files—copy [device:] filename [device:] filename
■ Marking files as deleted—delete [device:] filename
■ Squeezing Flash—squeeze device:
The Catalyst 5000 and 6000 family switches support two IP management interfaces—the in-
band management interface (sc0) and the Serial Line Internet Protocol (SLIP) interface (sl0).
The sc0 interface is attached to the switch’s switching fabric. The sc0 interface is an internal
management interface that participates in all the functions of a normal switch port, such as
Spanning Tree Protocol (STP), CDP, and VLAN membership. The SLIP interface is an out-
of-band management port because it is not attached to the switching fabric and no traffic is
switched over it.
The Catalyst 4000 family switches support three IP management interfaces: NOTE
Use a straight-through
■ sc0 patch cable to connect
■ sl0 the Supervisor module
me1 port to the TFTP
■ me1, which is an out-of-band management Ethernet interface server’s NIC. In this
sense, the me1 port acts
The 10/100 me1 interface is not attached to the switching fabric. If both the sc0 and me1 like a regular switch
interfaces are configured, the Supervisor Engine software determines which interface to use port. This requirement
is often a source of
when performing standard transmission and reception of IP packets based on the local rout-
confusion, considering
ing table. Operations that use this functionality include TFTP, ping, Telnet, and SNMP. that TFTP downloads
to routers are normally
When you configure the IP address, subnet mask, and broadcast address (and, on the sc0 done with crossover
interface, VLAN membership) of the sc0 or me1 interface, you can access the switch through cables.
Telnet or SNMP. When you configure the SLIP (sl0) interface, you can open a point-to-point
connection to the switch from a workstation through the console port.
sc0 does not have an external port for direct connection. It exists as a logical interface inside
the switch and is accessible via any of the physical ports on the switch.
me1 is actually a physical Ethernet port on the Supervisor module on the Catalyst 4000 family
switches. This interface is used for network management only and does not support network
switching.
1439_CCNP_3.book Page 728 Wednesday, October 27, 2004 9:54 AM

728 Appendix C: Using the Catalyst Operating System

The me1 or sc0 management interface must be assigned an address in the same subnet as the
TFTP server.
Example C-11 shows a TFTP download via the me1 interface. (The procedure is the same
for the sc0 interface.) Example C-11 shows the commands to set the me1 from the enable
prompt.

Example C-11 Configuring the IP for the me1 Interface on a Catalyst 4006

Console> (enable) set interface me1 172.16.0.5 255.255.255.0


Interface me1 IP address and netmask set.
Console> (enable)

NOTE You should confirm IP connectivity with the TFTP server by pinging the server as shown in
On some versions of Example C-12.
the CatOS, you get a
172.16.0.2 is alive mes-
Example C-12 Confirming Connectivity to the TFTP Server
sage instead of the typi-
cal Cisco ping output.
Console> (enable) ping 172.16.0.2
!!!!!
----172.16.0.2 PING Statistics----
5 packets transmitted, 5 packets received, 0% packet loss
round-trip (ms) min/avg/max = 14/15/17
Console> (enable)

Example C-13 demonstrates using the show flash command to check the contents of Flash
to confirm that space is available for the new image. In this case, the new image is
4,089,736 bytes.

Example C-13 Checking the Contents of Flash

Console> (enable) show flash


-#- ED --type-- --crc--- -seek-- nlen -length- -----date/time------ name
1 .. ffffffff 548c8f9c 39cf70 17 3526384 --- -- ---- --:--:--
cat4000.5-4-2.bin
12071928 bytes available (3526384 bytes used)
Console> (enable)
1439_CCNP_3.book Page 729 Wednesday, October 27, 2004 9:54 AM

Fundamentals of Switch Configuration 729

You are ready to copy the image from the TFTP server, as shown in Example C-14.

Example C-14 Copying the Image to Flash

Console> (enable) copy tftp flash


IP address or name of remote host [172.16.0.2]?
Name of file to copy from []? cat4000.6-2-1.bin
Flash device [bootflash]?
Name of file to copy to []? cat4000.6-2-1.bin
7981064 bytes available on device bootflash, proceed (y/n) [n]? y
CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC
CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC
File has been copied successfully.

Console> (enable)

To confirm that the file was downloaded, use the show flash or dir command, as shown in
Example C-15. You will see that both images are now present.

Example C-15 Verifying the New Image in Flash

Console> (enable) show flash


-#- ED --type-- --crc--- -seek-- nlen -length- -----date/time------ name
1 .. ffffffff 548c8f9c 39cf70 17 3526384 --- -- ---- --:--:--
cat4000.5-4-2.bin
2 .. ffffffff d39d5c46 783778 17 4089736 Apr 17 2001 14:40:15
cat4000.6-2-1.bin

7981192 bytes available (7616376 bytes used)

Console> dir
-#- -length- -----date/time------ name
1 3526384 --- -- ---- --:--:-- cat4000.5-4-2.bin
2 4089736 Apr 17 2001 14:40:15 cat4000.6-2-1.bin

7981192 bytes available (7616376 bytes used)


1439_CCNP_3.book Page 730 Wednesday, October 27, 2004 9:54 AM

730 Appendix C: Using the Catalyst Operating System

Use the set boot system flash bootflash: image_name prepend command to tell the switch
which image to use. It is critical that you use the prepend option to force the switch to load
the new image by default. Example C-16 illustrates the impact of the prepend option.

Example C-16 Reordering the Images in Flash

Console> (enable) set boot system flash bootflash:cat4000.6-2-1.bin prepend

Console> (enable) show config


<output omitted>
#set boot command
set boot config-register 0x2
set boot system flash bootflash:cat4000.6-2-1.bin
set boot system flash bootflash:cat4000.5-4-2.bin
<output omitted>

To delete the old image, use the delete command. Using the dir command shows you that the
file is gone, but actually it’s just marked as deleted (note that the “bytes available” and “bytes
used” have not changed). The file still appears in the output of the dir deleted command. To
really get rid of the image, you need to execute the command squeeze bootflash:. Example C-17
demonstrates this sequence of commands.

Example C-17 Deleting an Old Image

Console> (enable) delete cat4000.5-4-2.bin


Console> (enable) dir
-#- -length- -----date/time------ name
2 4089736 Apr 17 2001 14:40:15 cat4000.6-2-1.bin

7981192 bytes available (7616376 bytes used)


Console> (enable) dir deleted
-#- ED --type-- --crc--- -seek-- nlen -length- ----date/time---- name
1 .. ffffffff 548c8f9c 39cf70 17 3526384 -- -- ---- --:-:- cat4000.5-4-2.bin

7981192 bytes available (7616376 bytes used)

Console> (enable) squeeze bootflash:

All deleted files will be removed, proceed (y/n) [n]? y


1439_CCNP_3.book Page 731 Wednesday, October 27, 2004 9:54 AM

Fundamentals of Switch Configuration 731

Example C-17 Deleting an Old Image (Continued)

Squeeze operation may take a while, proceed (y/n) y

Console> (enable) dir


-#- -length- -----date/time------ name
1 4089736 Apr 17 2001 14:40:15 cat4000.6-2-1.bin

12070928 bytes available (4089736 bytes used)

You can use the same method to download configuration files from or upload configuration
files to a TFTP server. If you want to restore a previous configuration to a CatOS switch, enter
clear config all and then load the previous configuration. Note that the command write network
has the same effect as the copy config tftp command on a CatOS switch.

Port Descriptors
You can add a description to an interface or port to help facilitate switch administration, such
as documenting what access or distribution layer device the interface services. The set port
name command is very useful in an environment in which a switch has numerous connections
and the network engineer needs to check a link to a specific location. This description is meant
solely as a comment to help identify how the interface is being used or where it is connected
(such as which floor, which office, and so on). This description appears in the output when
you display the configuration information.
To assign a name to a port, use the command set port name mod_num/port_num [name_string].
Verify the configuration with the show port [mod_num[/port_num]] command. Note that the
show port command can have a module number as an argument.
Example C-18 shows how to set the name for ports 1/1 and 1/2 and how to verify that the port
names are configured correctly.

Example C-18 Configuring and Verifying Descriptive Identifiers for Ports

Console> (enable) set port name 1/1 Router Connection


Port 1/1 name set.
Console> (enable) set port name 1/2 Server Link
Port 1/2 name set.
Console> (enable) show port 1
continues
1439_CCNP_3.book Page 732 Wednesday, October 27, 2004 9:54 AM

732 Appendix C: Using the Catalyst Operating System

Example C-18 Configuring and Verifying Descriptive Identifiers for Ports (Continued)

Port Name Status Vlan Level Duplex Speed Type


----- ------------------ ---------- ---------- ------ ------ ----- ------------
1/1 Router Connection connected 1 normal full 1000 1000BaseSX
1/2 Server Link connected 1 normal full 1000 1000BaseSX

<output omitted>

Last-Time-Cleared
--------------------------
Tue Dec 28 2002, 16:25:57
Console> (enable)

Port Speed and Duplex


NOTE You can configure the port speed on 10/100-Mbps Fast Ethernet modules. To set the port
If the port speed is speed for a 10/100-Mbps port, perform this task in privileged mode. Use the set port speed
set to auto on a
mod num/port num {10 | 100 | auto} command. Verify the port speed configuration with the
10/100-Mbps Fast
Ethernet port, both show port [mod_num[/port_num]] command.
speed and duplex are
autonegotiated. Make Example C-19 shows how to set the port speed to 100 Mbps on port 2/3.
sure that the device on
the other end of the link Example C-19 Setting and Verifying Port Speed
is also configured for
auto-negotiation; other- Console> (enable) set port speed 2/3 100
wise, a port speed
Port(s) 2/3 speed set to 100Mbps.
mismatch or duplex
mismatch will result. Console> (enable) show port 2/3
Port Name Status Vlan Level Duplex Speed Type
----- ------------------ ---------- ---------- ------ ------ ----- ------------
2/3 connected 1 normal half 100 10/100BaseTX
<output omitted>

Console> (enable) set port speed 2/3 auto


Port(s) 2/3 speed set to auto detect.
Console> (enable) show port 2/3
Port Name Status Vlan Level Duplex Speed Type
----- ------------------ ---------- ---------- ------ ------ ----- ------------
2/3 connected 1 normal a-half a-100 10/100BaseTX
<output omitted>
1439_CCNP_3.book Page 733 Wednesday, October 27, 2004 9:54 AM

Fundamentals of Switch Configuration 733

You can set the port duplex mode to full- or half-duplex for Ethernet and Fast Ethernet ports. NOTE
You cannot change the duplex mode of ports configured for auto-negotiation. To set a On 1000BASE-T
Gigabit Ethernet ports,
port’s duplex mode, use the command set port duplex mod num/port num {full | half}, and
you cannot configure
verify with the show port command, as shown in Example C-20. speed or duplex mode.
1000BASE-T ports
Example C-20 Setting and Verifying Port Duplex operate only in the
default configuration,
Console> (enable) set port duplex 2/3 half where the speed is 1000
and the duplex mode is
Port(s) 2/3 set to half-duplex.
full. You cannot disable
Console> (enable) show port 2/3 auto-negotiation.
Port Name Status Vlan Level Duplex Speed Type In general, for Catalyst
switches, Gigabit
----- ------------------ ---------- ---------- ------ ------ ----- ------------ Ethernet and 10 Gigabit
2/3 connected 1 normal half 100 10/100BaseTX Ethernet are full-duplex
only. You cannot change
<output omitted>
the duplex mode on
Gigabit Ethernet and
10 Gigabit Ethernet
ports. To determine
which features an
Ethernet port supports,
enter the show port
capabilities mod_num
command.
1439_CCNP_3.book Page 734 Monday, November 1, 2004 11:16 AM
1439_CCNP_3.book Page 735 Wednesday, October 27, 2004 9:54 AM

Glossary

access port A switch port that connects to an end-user device or a server.


adjacency table One of three tables used by CEF. The adjacency table is a database of node
adjacencies (two nodes are said to be adjacent if they can reach each other via a single Layer 2
hop) and their associated Layer 2 MAC rewrite or next-hop information. Each leaf of the FIB
tree offers a pointer to the appropriate next-hop entry in the adjacency table.
aging time The IP MLS aging time determines the amount of time before an MLS entry is
aged out. The default is 256 seconds. You can configure the aging time in the range of 8 to
2032 seconds in 8-second increments.
Application-Specific Integrated Circuit (ASIC) A chip designed for a particular application
(as opposed to the integrated circuits that control functions such as RAM).
ATM LAN Emulation (ATM LANE) A standard defined by the ATM Forum that gives two
stations attached via ATM the same capabilities they normally have with Ethernet and Token
Ring.
Auto-RP A PIM feature that automates the distribution of group-to-RP mappings.
BackboneFast A Catalyst feature that is initiated when a Root Port or Blocked Port on a
switch receives inferior BPDUs from its Designated Bridge. Max Age is skipped to allow
appropriate blocked ports to transition quickly to Forwarding state in the case of an indirect link
failure.
Blocking state The STP state in which a bridge listens for BPDUs. This state follows the
Disabled state.
Bridge ID (BID) An 8-byte field consisting of an ordered pair of numbers—a 2-byte decimal
number called the Bridge Priority and a 6-byte (hexadecimal) MAC address.
Bridge Priority A decimal number used to measure the preference of a bridge in the Spanning
Tree Algorithm. The possible values range between 0 and 65,535.
Bridge Protocol Data Unit (BPDU) A frame used by switches and bridges to communicate
spanning-tree information.
1439_CCNP_3.book Page 736 Wednesday, October 27, 2004 9:54 AM

736 Glossary

broadcast domain The set of all devices that receive broadcast frames originating from any
device in the set. Broadcast domains are typically bounded by routers because routers do not
forward broadcast frames.
candidate packet When a source initiates a data transfer to a destination, it sends the first
packet to the MLS-RP through the MLS-SE. The MLS-SE recognizes the packet as a candidate
packet for Layer 3 switching, because the MLS-SE has learned the MLS-RP’s destination
MAC addresses and VLANs through MLSP. The MLS-SE learns the candidate packet’s
Layer 3 flow information (such as the destination address, source address, and protocol port
numbers) and forwards the candidate packet to the MLS-RP. A partial MLS entry for this
Layer 3 flow is created in the MLS cache.
candidate RP A router that announces its candidacy to be an RP for a PIM-SM network via
the Cisco-Announce group, 224.0.1.39.
central rewrite engine The Catalyst 5000 NFFC contains central rewrite engines (one per
bus) to handle PDU header rewrites when inline rewrite is not an option. If the central rewrite
engines are used, this means that a frame must traverse the bus twice—first with a VLAN tag
for the source (on its way to the NFFC) and second with a VLAN tag for the destination (on
its way to the egress port).
Cisco Express Forwarding (CEF) A Cisco multilayer switching technology that allows for
increased scalability and performance to meet the requirements for large enterprise networks.
CEF has evolved to accommodate the traffic patterns realized by modern networks, character-
ized by an increasing number of short-duration flows.
Cisco Group Management Protocol (CGMP) A Cisco-developed protocol that runs
between Cisco routers and Catalyst switches to leverage IGMP information on Cisco routers
to make Layer 2 forwarding decisions on Catalyst switch ports that are attached to interested
receivers. With CGMP, IP multicast traffic is delivered only to Catalyst switch ports that are
attached to interested receivers.
class of service (CoS) 802.1Q frame headers have a 2-byte Tag Control Information field
that carries the CoS value in the 3 most significant bits. Layer 2 CoS values range from 0 for
low priority to 7 for high priority. CoS is used with QoS, especially at the network’s access
layer.
class-based traffic shaping Allows you to control the traffic going out an interface to match
its transmission to the speed of the remote, target interface and to ensure that the traffic con-
forms to policies contracted for it. Traffic adhering to a particular profile can be shaped to
meet downstream requirements, thereby eliminating bottlenecks in topologies with data-rate
mismatches. Can be enabled on any interface that supports GTS.
1439_CCNP_3.book Page 737 Wednesday, October 27, 2004 9:54 AM

Glossary 737

Class-Based Weighted Fair Queuing (CBWFQ) Extends the standard WFQ functionality
to provide support for user-defined traffic classes. For CBWFQ, you define traffic classes
based on match criteria including protocols, access control lists (ACLs), and input interfaces.
Packets satisfying the match criteria for a class constitute the traffic for that class. A FIFO
queue is reserved for each class, and traffic belonging to a class is directed to the queue for
that class.
classification Using a traffic descriptor to categorize a packet within a specific group to
define that packet and make it accessible for QoS handling on the network.
clustering A method of managing a group of switches without having to assign an IP
address to every switch.
Coarse Wavelength Division Multiplexing (CWDM) A technology that employs multiple
light wavelengths to transmit signals over a single optical fiber. CWDM technology is based
on the same WDM concept as DWDM technology. The two technologies differ primarily in
the spacing of the wavelengths, the number of channels, and the capability to amplify signals
in the optical space.
codec Coder-decoder. An integrated circuit device that typically uses pulse code modulation
to transform analog signals into a digital bit stream and digital signals back into analog sig-
nals. In voice over IP, voice over Frame Relay, and voice over ATM, a codec refers to a DSP
software algorithm used to compress/decompress speech or audio signals.
collision domain In Ethernet, the network area within which frames that have collided are
propagated. Repeaters and hubs propagate collisions; LAN switches, bridges, and routers
do not.
Committed Access Rate (CAR) A rate-limiting feature for policing traffic. It manages a
network’s access bandwidth policy by ensuring that traffic falling within specified rate
parameters is sent, while dropping packets that exceed the acceptable amount of traffic or
sending them with a different priority. The exceed action for CAR is to drop or mark down
packets.
Common Spanning Tree (CST) A spanning-tree implementation specified in the IEEE
802.1Q standard. CST defines a single instance of spanning tree for all VLANs with BPDUs
transmitted over VLAN 1.
Compressed Real-Time Transport Protocol (CRTP) An RTP header compression feature
used on a link-by-link basis.
Conjugate Structure Algebraic Code Excited Linear Prediction (CS-ACELP) A CELP
voice compression algorithm providing 8 kbps, or 8:1 compression. Standardized in ITU-T
Recommendation G.729.
1439_CCNP_3.book Page 738 Wednesday, October 27, 2004 9:54 AM

738 Glossary

Content-Addressable Memory (CAM) Memory that is accessed based on its contents, not
on its memory address. Sometimes called associative memory.
core In CBT, the router that serves as the root of the shared tree. Similar to PIM-SM’s RP.
Core-Based Trees (CBT) A multicast routing protocol introduced in September 1997 in
RFC 2201, CBT builds a shared tree like PIM-SM. CBT uses information in the IP unicast
routing table to calculate the next-hop router in the direction of the core.
default gateway Provides a definitive location for IP packets to be sent in case the source
device has no IP routing functionality built into it. This is the method most end stations use to
access nonlocal networks. The default gateway can be set manually or learned from a DHCP
server.
default VLAN Upon initial switch configuration, all switch ports can be configured to be
members of a particular VLAN other than VLAN 1. This particular VLAN is the default
VLAN. When a user plugs a device into the switch, it automatically is associated with the
default VLAN. If, upon initial switch configuration, not all switch ports are configured to
be members of a VLAN other than VLAN 1, VLAN 1 is the default VLAN.
delay Also known as latency. Refers to the time it takes a packet to travel from the source to
the destination.
delay variation See jitter.
Dense Wavelength Division Multiplexing (DWDM) A technology that employs multiple
light wavelengths to transmit signals over a single optical fiber.
Designated Bridge The Designated Bridge for a segment is the bridge containing the
Designated Port for that segment.
Designated Port The Designated Port for a segment is the bridge port connected to the seg-
ment that both sends traffic toward the Root Switch and receives traffic from the Root Switch
over that segment.
Differentiated Services Code Point (DSCP) The first 6 bits of the ToS field. Used to classify
IP traffic.
Disabled state The administratively shut-down STP state.
Distance Vector Multicast Routing Protocol (DVMRP) The first multicast routing protocol,
publicized in RFC 1075 in 1998. Unlike PIM, DVMRP builds a separate multicast routing
table from the unicast routing table.
distribution tree A unique forwarding path for a multicast group between the source and
each subnet containing members of the multicast group.
1439_CCNP_3.book Page 739 Wednesday, October 27, 2004 9:54 AM

Glossary 739

Dynamic Packet Transport (DPT) A resilient packet ring technology designed to deliver
scalable Internet service, reliable IP-aware optical transport, and simplified network operations.
Dynamic Trunking Protocol (DTP) A Cisco-proprietary protocol that autonegotiates trunk
formation for either ISL or 802.1Q trunks.
Dynamic VLAN A VLAN in which end stations are automatically assigned to the appropri-
ate VLAN based on their MAC address. This is made possible via a MAC address-to-VLAN
mapping table contained in a VLAN Management Policy Server (VMPS) database.
E.164 An ITU-T recommendation for international telecommunication numbering, espe-
cially in ISDN, BISDN, and SMDS. An evolution of standard telephone numbers. Also, the
name of the field in an ATM address that contains numbers in E.164 format.
edge port With RSTP, an edge port is functionally equivalent to a port configured with Port-
Fast under PVST+. An edge port immediately transitions to the Forwarding state. An edge
port should be configured only on ports that connect to a single end station.
Emulated LAN (ELAN) A logical construct, implemented with switches, that provides
Layer 2 communication between a set of hosts in a LANE network. See ATM LAN Emulation
(ATM LANE).
enable packet When an MLS-SE receives a packet from the MLS-RP that originated as a
candidate packet, it recognizes that the source MAC address belongs to the MLS-RP, that the
XTAG matches that of the candidate packet, and that the packet’s flow information matches
the flow for which the candidate entry was created. The MLS-SE considers this packet an
enable packet and completes the MLS entry created by the candidate packet in the MLS
cache.
end-to-end VLAN Also known as a campus-wide VLAN. An end-to-end VLAN spans a
campus network. It is characterized by the mapping to a group of users carrying out a similar
job function (independent of physical location).
EtherChannel A Cisco-proprietary technology that, by aggregating links into a single logi-
cal link, provides incremental trunk speeds ranging from 100 Mbps to 160 Gbps.
fast aging time The IP MLS fast aging time is the amount of time before an MLS entry is
purged that has no more than pkt_threshold packets switched within fastagingtime seconds
after it is created.
flow A unidirectional sequence of packets between a particular source and destination that
share the same Layer 3 and Layer 4 PDU header information.
flow mask A set of criteria, based on a combination of source IP address, destination IP
address, protocol, and protocol ports, that describes the characteristics of a flow.
forward delay How much time the bridge spends in the Listening and Learning states.
1439_CCNP_3.book Page 740 Wednesday, October 27, 2004 9:54 AM

740 Glossary

Forwarding Information Base (FIB) One of three tables used by CEF. The FIB table con-
tains the minimum information necessary to forward packets; in particular, it does not contain
any routing protocol information. The table consists of a four-level hierarchical tree, with 256
branch options per level (reflecting four octets in an IP address).
Forwarding state The STP state in which data traffic is both sent and received on a port. It
is the last STP state, following the Learning state.
Frame Relay Traffic Shaping (FRTS) Eliminates bottlenecks in Frame Relay networks
that have high-speed connections at the central site and low-speed connections at branch sites.
You configure rate enforcement, a peak rate configured to limit outbound traffic, to limit the
rate at which data is sent on the virtual circuit (VC) at the central site. Using FRTS, you can
configure rate enforcement to either the CIR or some other defined value, such as the excess
information rate, on a per-VC basis. The ability to allow the transmission speed used by the
router to be controlled by criteria other than line speed (that is, by the CIR or the excess infor-
mation rate), which provides a mechanism for multiple VCs to share media. You can allocate
bandwidth to each VC, creating a virtual time-division multiplexing (TDM) network.
G.711 Describes the 64-kbps PCM (Pulse Code Modulation) voice-coding technique. In
G.711, encoded voice is already in the correct format for digital voice delivery in the PSTN
or through PBXs. Described in the ITU-T standard in its G-series recommendations.
G.726 Describes Adaptive Differential Pulse Code Modulation (ADPCM) coding at 40, 32,
24, and 16 kbps. ADPCM-encoded voice can be interchanged between packet voice, PSTN,
and PBX networks if the PBX networks are configured to support ADPCM. Described in the
ITU-T standard in its G-series recommendations.
G.729 Describes CELP compression in which voice is coded into 8-kbps streams. This
standard has two variations (G.729 and G.729 Annex A) that differ mainly in computational
complexity; both provide speech quality similar to 32-kbps ADPCM. Described in the ITU-T
standard in its G-series recommendations.
Gateway Load Balancing Protocol (GLBP) A Cisco-proprietary protocol that protects data
traffic from a failed router or circuit, like HSRP and VRRP, while allowing packet load shar-
ing between a group of redundant routers.
Generic Traffic Shaping (GTS) Shapes traffic by reducing outbound traffic flow to avoid
congestion by constraining traffic to a particular bit rate using the token bucket mechanism.
GTS applies on a per-interface basis and can use access lists to select the traffic to shape. It
works with a variety of Layer 2 technologies, including Frame Relay.
globally scoped addresses A multicast address space in the range from 224.0.1.0 to
238.255.255.255. These addresses can be used to multicast data between organizations and
across the Internet.
1439_CCNP_3.book Page 741 Wednesday, October 27, 2004 9:54 AM

Glossary 741

GLOP address RFC 2770 proposes that the 233.0.0.0/8 address range be reserved for stati-
cally defined addresses by organizations that already have an AS number reserved. The second
and third octets are populated with the decimal equivalents of the first and second bytes of the
hexadecimal representation of the AS number.
H.320 A suite of ITU-T standard specifications for videoconferencing over circuit-
switched media such as ISDN, fractional T1, and switched-56 lines.
H.323 An extension of ITU-T standard H.320 that enables videoconferencing over LANs
and other packet-switched networks, as well as video over the Internet. H.323 is a set of com-
munications protocols used by programs, such as Microsoft NetMeeting, and equipment,
such as Cisco routers, to transmit and receive audio and video information over the Internet.
Hello interval The time that elapses between the sending of HSRP Hello packets. The
default is 3 seconds.
Hello time The time interval between the sending of Configuration BPDUs.
holdtime The time it takes before HSRP routers in an HSRP group declare the active router
to be down. The default is 10 seconds.
Hot Standby Router Protocol (HSRP) The Layer 3 Cisco-proprietary protocol that allows
a set of routers on a LAN segment to work together to present the appearance of a single virtual
router or default gateway to the hosts on the segment. HSRP provides high network availabil-
ity and transparent network topology changes. It creates a hot standby router group with a
lead router that services all packets sent to the hot standby address. HSRP enables fast rerout-
ing to alternate default gateways should one of them fail. The lead router is monitored by
other routers in the group, and if it fails, one of these standby routers inherits the lead position
and the hot standby group address.
HSRP group Routers on a subnet, VLAN, or subset of a subnet participating in an HSRP
process. Each group shares a virtual IP address. The group is defined on the HSRP routers.
HSRP state The descriptor for the current HSRP condition for a particular router interface
and a particular HSRP group. The possible HSRP states are Initial, Learn, Listen, Speak,
Standby, and Active.
ICMP Router Discovery Protocol (IRDP) Hosts supporting IRDP dynamically discover
routers to access nonlocal networks. IRDP allows hosts to locate routers (default gateways).
Router discovery packets are exchanged between hosts (IRDP servers) and routers (IRDP
clients).
IEEE 802.10 The IEEE standard that provides a method for transporting VLAN informa-
tion inside the IEEE 802.10 frame (FDDI). The VLAN information is written to the security
association identifier (SAID) portion of the 802.10 frame. This allows for transporting
VLANs across FDDI backbones.
1439_CCNP_3.book Page 742 Wednesday, October 27, 2004 9:54 AM

742 Glossary

IEEE 802.1Q The IEEE standard for identifying VLANs associated with Ethernet frames.
IEEE 802.1Q trunking works by inserting a VLAN identifier into the Ethernet frame header.
IEEE 802.1x A standard defining a client/server-based access control and authentication
protocol that restricts unauthorized clients from connecting to a LAN through publicly acces-
sible ports. The authentication server authenticates each client connected to a switch port
before making available any services offered by the switch or the LAN. Until the client is
authenticated, 802.1X access control allows only Extensible Authentication Protocol over
LAN (EAPOL) traffic through the port to which the client is connected. After authentication
is successful, normal traffic can pass through the port.
■ If a router receives a datagram on an interface it uses to send unicast packets to the
source, the packet has arrived on the RPF interface.
■ If the packet arrives on the RPF interface, a router forwards the packet out the inter-
faces present in the outgoing interface list of a multicast routing table entry.
■ If the packet does not arrive on the RPF interface, the packet is silently discarded to
prevent loops.
IGMP leave group message A message used by IGMPv2 to allow a host to announce its
intention to leave a multicast group. The leave message is sent to the all-routers multicast
address, 224.0.0.2.
IGMP membership query A message used by IGMP and sent to the all-hosts multicast
address, 224.0.0.1, to verify that at least one host on the subnet is still interested in receiving
traffic directed to that group. Also referred to as a general query.
IGMP membership report A message used by IGMP to indicate a host’s interest in receiv-
ing traffic for a particular multicast group.
IGMP snooping A Layer 2 multicast constraining mechanism (like CGMP) used by
switches, allowing only multicast traffic to be forwarded to those interfaces associated with
IP multicast devices. The switch snoops on the IGMP traffic between the host and the router
and keeps track of multicast groups and member ports.
IGMP Version 1 A version of IGMP that relies solely on membership query messages and
membership report messages.
IGMP Version 2 A version of IGMP that adds the ability of a host to proactively leave a
multicast group and the ability of a router to send a group-specific query (as opposed to
a general query).
IGMP Version 3 A version of IGMP that adds support for source filtering.
1439_CCNP_3.book Page 743 Wednesday, October 27, 2004 9:54 AM

Glossary 743

inline rewrite Some Catalyst 5000 family switch line cards have onboard hardware that
performs PDU header rewrites and forwarding, maximizing IP MLS performance. When the
line card performs the PDU header rewrites, this is called inline rewrite. With inline rewrite,
frames traverse the switch bus only once.
Internet Control Message Protocol (ICMP) A network layer Internet protocol that reports
errors and provides other information relevant to IP packet processing. Documented in
RFC 792.
Internet Group Management Protocol (IGMP) A protocol used by IP hosts to communi-
cate to local multicast routers their desire to receive multicast traffic. The hosts report their
multicast group memberships to an adjacent multicast router.
Inter-Switch Link (ISL) A Cisco-proprietary encapsulation protocol for creating trunks.
ISL prepends a 26-byte header and appends a 4-byte CRC to each data frame.
IP Precedence 3 bits in the ToS field of the IP header used to specify a packet’s class of
service.
jitter Also known as delay variation. The difference in the delay times of consecutive packets.
Kerberos A secret-key network authentication protocol used with AAA that uses the Data
Encryption Standard (DES) cryptographic algorithm for encryption and authentication. Kerberos
was designed to authenticate requests for network resources. It is based on the concept of a
trusted third party that performs secure verification of users and services.
LAN Emulation (LANE) An ATM Forum standard used to transport VLANs over ATM
networks.
latency See delay.
Learning state The STP state in which the bridge does not pass user data frames but builds
the bridging table and gathers information, such as the source VLANs of data frames. This
state follows the Listening state.
limited scope address Also called an administratively scoped address. It falls in the range
239.0.0.0 to 239.255.255.255 and is limited for use by a local group or organization.
Link Aggregation Control Protocol (LACP) Allows Cisco switches to manage Ethernet
channels with non-Cisco devices conforming to the 802.3ad specification. Defined in
IEEE 802.3ad.
Link Fragmentation and Interleaving (LFI) A feature that reduces delay on slower-speed
links by breaking up large datagrams and interleaving low-delay traffic packets with the
smaller packets resulting from the fragmented datagram.
1439_CCNP_3.book Page 744 Wednesday, October 27, 2004 9:54 AM

744 Glossary

link local address An IANA reserved multicast address space in the range from 224.0.0.0 to
224.0.0.255 to be used by network protocols on a local network segment.
Listening state The STP state in which no user data is passed, but the port sends and
receives BPDUs in an effort to determine the active topology. It is during the Listening state
that the three initial convergence steps take place—elect a Root Switch, elect Root Ports, and
elect Designated Ports. This state follows the Blocking state.
local VLAN Also known as a geographic VLAN. A local VLAN is defined by a restricted
geographic location, such as a wiring closet.
loss The percentage of packets that fail to reach their destination.
Low Latency Queuing (LLQ) Brings strict priority queuing to CBWFQ. Strict priority
queuing allows delay-sensitive data, such as voice, to be dequeued and sent first (before packets
in other queues are dequeued), giving delay-sensitive data preferential treatment over other
traffic.
management VLAN Most of today’s switches and routers can be accessed remotely via
Telnet or SSH to the device’s management IP address. The recommended practice is to put
these and other networking devices in their own VLAN, known as the management VLAN.
The management VLAN should be a separate VLAN, independent of any user VLANs, the
native VLAN, and VLAN 1.
Max Age An STP timer that controls how long a bridge stores a BPDU before discarding it.
The default is 20 seconds.
MBONE A multicast backbone across the public Internet, built with tunnels between
DVMRP-capable Sun workstations running the mroute daemon (process).
MLS Route Processor (MLS-RP) A Cisco device with a route processor that supports
MLS. For example, a Catalyst 3620 router is an MLS-RP.
MLS Switching Engine (MLS-SE) A set of hardware components on a Catalyst switch,
excluding the route processor, necessary to support MLS. For example, a Catalyst 5000 with
a Supervisor Engine IIIG is an MLS-SE.
MLS-RP Management Interface The MLS-RP interface that sends hello messages, adver-
tises routing changes, and announces VLANs and MAC addresses of interfaces participating
in MLS.
Mono Spanning Tree (MST) The spanning-tree implementation used by non-Cisco 802.1Q
switches. One instance of STP is responsible for all VLAN traffic.
1439_CCNP_3.book Page 745 Wednesday, October 27, 2004 9:54 AM

Glossary 745

multicast group An arbitrary group of hosts that expresses an interest in receiving a partic-
ular data stream via multicast. This group has no physical or geographic boundaries. Hosts
that are interested in receiving data flowing to a particular group must join the group using
IGMP.
Multicast OSPF (MOSPF) A multicast routing protocol specified in RFC 1584. MOSPF is
a set of extensions to OSPF, enabling multicast forwarding decisions.
Multilayer Switch Feature Card (MSFC) MSFC1 and MSFC2 are daughter cards to the
Catalyst 6000 Supervisor Engine. They provide multilayer switching functionality and rout-
ing services between VLANs.
Multilayer Switch Module (MSM) A line card for Catalyst 6000 family switches that runs
the Cisco IOS router software and directly interfaces with the Catalyst 6000 backplane to
provide Layer 3 switching.
Multilayer Switching (MLS) A specific multilayer switching technology employed by var-
ious Cisco devices to perform wire-speed PDU header rewrites. The first packet in a flow is
routed as normal, and the MLS-SE switches subsequent packets based on cached information.
Multilayer Switching Protocol (MLSP) A protocol used to communicate MLS information
between the MLS-SE and MLS-RP. In particular, the MLS-SE populates its Layer 2 CAM
table with updates received from MLSP packets.
Multiple Instances of Spanning Tree Protocol (MISTP) Lets you group multiple VLANs
under a single instance of spanning tree. MISTP combines the Layer 2 load-balancing bene-
fits of PVST+ with the lower CPU load of IEEE 802.1Q.
Multiple Spanning Tree (MST) Extends the IEEE 802.1w Rapid Spanning Tree (RST)
algorithm to multiple spanning trees, as opposed to the single CST of the original IEEE
802.1Q specification. This extension provides for both rapid convergence and load sharing in
a VLAN environment.
native VLAN The IEEE committee that defined 802.1Q decided that, for backward compat-
ibility, it was desirable to associate all untagged traffic on an 802.1Q link with a specific
VLAN—the native VLAN. This VLAN is implicitly used for all the untagged traffic received
on an 802.1Q-capable port. A trunk port reverts to the native VLAN if trunking is disabled on
the port.
NetFlow Feature Card (NFFC) A daughter card for a Catalyst 5000 Supervisor module
that enables intelligent network services, such as high-performance multilayer switching and
accounting and traffic management.
1439_CCNP_3.book Page 746 Wednesday, October 27, 2004 9:54 AM

746 Glossary

NetFlow table One of three tables used by CEF. The NetFlow table provides network
accounting data. It is updated in parallel with the CEF-based forwarding mechanism provided
by the FIB and adjacency tables.
Network Analysis Module (NAM) A LAN monitoring solution that should be deployed at
LAN aggregation points where it can see critical traffic and virtual LANs (VLANs).
Network Time Protocol (NTP) Used to synchronize clocks on network devices. The multi-
cast address 224.0.1.1 is reserved for NTP operation.
nonblocking The ability to switch a packet immediately without encountering a busy
condition.
Path Cost An STP measure of how close bridges are to each other. Path Cost is the sum of
the costs of the links in a path between two bridges.
Per-VLAN Spanning Tree (PVST) A Cisco-proprietary spanning-tree implementation
requiring ISL trunk encapsulation. PVST runs a separate instance of STP for each VLAN.
PIM sparse-dense mode An alternative to pure dense mode or pure sparse mode for a
router interface. Sparse-dense mode allows individual groups to be run in either sparse or
dense mode, depending on whether RP information is available for that group. If the router
learns RP information for a particular group, it is treated as sparse mode; otherwise, that
group is treated as dense mode.
Policy Feature Card (PFC) Performs hardware-based Layer 2 to 4 packet forwarding as
well as packet classification, traffic management, and policy enforcement.
Port ACL ACLs can be applied to Layer 2 interfaces on a switch. Port ACLs are supported
on Layer 2 physical interfaces only, not on EtherChannel interfaces. Port ACLs are applied on
interfaces for inbound traffic only. They support standard IP access lists using source addresses,
extended IP access lists using source and destination addresses and optional protocol type
information, and MAC extended access lists using source and destination MAC addresses
and optional protocol type information.
Port Aggregation Protocol (PAgP) A Cisco-proprietary technology that facilitates the auto-
matic creation of EtherChannels by exchanging packets between Ethernet interfaces.
Port ID A 2-byte STP parameter consisting of an ordered pair of numbers—the Port
Priority and the Port Number.
Port Number A numerical identifier used by Catalyst switches to enumerate the ports.
Port Priority A configurable STP parameter with values ranging from 0 to 63 on a CatOS
switch (the default is 32) and from 0 to 255 on an IOS-based switch (the default is 128). Port
Priority is used to influence Root Switch selection when all other STP parameters are equal.
1439_CCNP_3.book Page 747 Wednesday, October 27, 2004 9:54 AM

Glossary 747

port-based VLAN Also known as a static VLAN. A port-based VLAN is configured manu-
ally on a switch, where ports are mapped, one by one, to the configured VLAN. This hard-
codes the mapping between ports and VLANs directly on each switch.
PortFast A Catalyst feature that, when enabled, causes an access or trunk port to enter the
spanning-tree Forwarding state immediately, bypassing the Listening and Learning states.
preempt An HSRP feature that lets a router with the highest priority immediately assume
the active role at any time.
priority An HSRP parameter used to facilitate the election of an active HSRP router for an
HSRP group on a LAN segment. The default priority is 100. The router with the greatest pri-
ority for each group is elected as the active forwarder for that group.
private VLAN A VLAN you configure to have some Layer 2 isolation from other ports
within the same private VLAN. Ports belonging to a private VLAN are associated with a
common set of supporting VLANs that create the private VLAN structure.
Protocol-Independent Multicast (PIM) An IP multicast routing protocol that derives its
information using RPF checks based on the unicast routing table. PIM has several variations,
including dense mode, sparse mode, sparse-dense mode, source-specific mode, and bidirec-
tional mode.
Protocol-Independent Multicast Dense Mode (PIM-DM) A PIM variation that builds a
source tree for each multicast source and uses flood-and-prune behavior.
Protocol-Independent Multicast Sparse Mode (PIM-SM) A PIM variation that builds
shared trees. The root of the tree is called the rendezvous point, similar to CBT’s core.
proxy ARP Proxy ARP allows an Ethernet host with no knowledge of routing to communi-
cate with hosts on other networks or subnets. Such a host assumes that all hosts are on the
same local segment and that it can use ARP to determine their hardware addresses. The proxy
ARP function is handled by routers.
PVST+ A Cisco-proprietary implementation that allows CST and PVST to exist on the
same network.
RADIUS A client/server authentication and accounting protocol for use with access servers.
RADIUS is specified in RFCs 2865, 2866, and 2868.
Rapid Spanning Tree Protocol (RSTP) An evolution of Spanning Tree Protocol (802.1D
standard) that provides for faster spanning-tree convergence after a topology change. The
standard also includes features equivalent to Cisco PortFast, UplinkFast, and BackboneFast
for faster network reconvergence.
1439_CCNP_3.book Page 748 Wednesday, October 27, 2004 9:54 AM

748 Glossary

Remote Monitoring (RMON) A monitoring specification that lets various network moni-
tors and console systems exchange network-monitoring data. RMON gives network adminis-
trators more freedom in selecting network-monitoring probes and consoles with features that
meet their particular networking needs.
Reverse Path Forwarding (RPF) An algorithm used to forward multicast datagrams.
Root Bridge The bridge/switch with the lowest Bridge ID for that VLAN. Each VLAN has
a Root Bridge. Also called the Root Switch.
Root Path Cost The cumulative cost of all links to the Root Switch.
Root Port A port on a bridge closest to the Root Switch in terms of Path Cost.
Root Switch See Root Bridge.
route processor The main system processor in a Layer 3 networking device, responsible for
managing tables and caches and for sending and receiving routing protocol updates.
Route Switch Feature Card (RSFC) A daughter card to the Catalyst 5000/5500 Supervisor
Engine IIG and IIIG that provides inter-VLAN routing and multilayer switching functional-
ity. The RSFC runs Cisco IOS router software and directly interfaces with the Catalyst switch
backplane.
Route Switch Module (RSM) A line card that interfaces with the Supervisor Engine of a
Catalyst 5000/5500 switch to provide inter-VLAN routing functionality. The RSM runs the
Cisco IOS.
Router ACL An ACL that can be applied to SVIs, physical Layer 3 interfaces, and Layer 3
EtherChannel interfaces. Router ACLs are applied on interfaces for specific directions
(inbound or outbound). One IP access list in each direction can be specified.
router-on-a-stick A method of inter-VLAN routing consisting of an external router with a
Fast Ethernet, Gigabit Ethernet, or EtherChannel trunk connecting to a switch, using ISL or
802.1Q. Subinterfaces on the trunk are created to correspond with VLANs in a one-to-one
fashion.
Router-Port Group Management Protocol (RGMP) Lets a router communicate to a switch
in the IP multicast group for which the router wants to receive or forward traffic. RGMP is
designed for switched Ethernet backbone networks running PIM.
RP mapping agent A router that receives the RP-announcement messages from the candi-
date RPs and arbitrates conflicts. The RP mapping agent sends the group-to-RP mappings to
all multicast-enabled routers via the Cisco-Discovery group, 224.0.1.40.
1439_CCNP_3.book Page 749 Wednesday, October 27, 2004 9:54 AM

Glossary 749

RSPAN An implementation of SPAN designed to support source ports, source VLANs, and
destination ports across different switches. RSPAN allows remote monitoring of multiple
switches across a network.
scheduling The process of assigning packets to one of multiple queues, based on classifica-
tion, for priority treatment through the network.
Secure Shell (SSH) A program to log into another computer over a network, to execute
commands in a remote machine, and to move files from one machine to another. It provides
strong authentication and secure communications over insecure channels.
Server Load Balancing (SLB) Balances services across numerous servers at speeds of mil-
lions of packets per second. Commonly deployed with the Cisco IOS software on Catalyst
6000 family of switches. SLB is a software solution using the advanced application-specific
integrated circuits (ASICs) on the Catalyst 6000.
shared tree A multicast distribution tree using a root placed at some chosen point in the
network. PIM-SM and CBT both use shared trees. When using a shared tree, sources must
send their traffic to the root for the traffic to reach the receivers.
Single Router Mode (SRM) Addresses the drawback of the previous HSRP-based MSFC
redundancy scheme (designated MSFC versus nondesignated MSFC). When SRM is enabled,
the nondesignated router is online, but all its interfaces are down. Thus, it does not hold any
routing table information. This means that if the DR fails, there will be some delay before
the nondesignated router coming online has a complete route table. To help account for this,
the information being used before the failure by the Supervisor for Layer 3 forwarding is
maintained and updated with any new information from the new designated router.
source filtering A capability added to IGMPv3 that lets a multicast host signal to a router
the groups for which it wants to receive multicast traffic and the sources from which it wants
to receive the traffic.
source tree A multicast distribution tree with root at the source of the multicast traffic and
whose branches form a spanning tree through the network to the receivers. Also called the
shortest path tree (SPT). For every source of a multicast group, there is a corresponding SPT.
Spanning Tree Protocol (STP) A Layer 2 bridge protocol that uses the spanning-tree algo-
rithm, allowing a learning bridge to dynamically work around loops in a network topology
by creating a spanning tree. Bridges exchange BPDU messages with other bridges to detect
loops and then remove the loops by shutting down selected bridge interfaces. STP refers to
both the IEEE 802.1 Spanning Tree Protocol standard and the earlier Digital Equipment
Corporation Spanning Tree Protocol on which it is based. The IEEE version supports bridge
domains and allows the bridge to construct a loop-free topology across an extended LAN.
The IEEE version is generally preferred over the digital version.
1439_CCNP_3.book Page 750 Wednesday, October 27, 2004 9:54 AM

750 Glossary

Switch Fabric Module (SFM) A line card that delivers an increase in available system
bandwidth on a Catalyst 6500 switch from the default 32 Gbps on the forwarding bus to
256 Gbps. Including an SFM in a Catalyst 6500 chassis increases the speed at which switch-
ing, routing, and network monitoring modules can transfer data between each other. The SFM
reduces latency and the incidence of packet drop caused by bandwidth bottlenecks at traffic
aggregation points within the network.
Switched Port Analyzer (SPAN) A tool used with Catalyst switches to enable the capture of
traffic. A SPAN session is an association of a destination port with a set of source ports, con-
figured with parameters that enable the monitoring of network traffic.
Synchronous Digital Hierarchy (SDH) A standard for interfacing operating telephone
company optical networks. SDH and SONET form a set of global standards that interface
equipment from different vendors.
Synchronous Optical Network (SONET) A standard for interfacing operating telephone
company optical networks. SONET and SDH form a set of global standards that interface
equipment from different vendors.
TACACS+ A Cisco-proprietary protocol used to authenticate users against a database.
TACACS+ uses TCP to communicate between a TACACS+ server and a TACACS+ client.
tracking This HSRP feature allows you to specify other interfaces on the router for the
HSRP process to monitor. If the tracked interface goes down, the HSRP standby router takes
over as the active router. This process is facilitated by a decrement to the HSRP priority
resulting from the tracked interface line protocol going down.
Transparent LAN Services (TLS) A set of technologies that lets the service provider pro-
vide native LAN services over wide-area links without the need to implement complicated
and costly ATM networks.
trunk A point-to-point link connecting a switch to another switch, router, or server. A trunk
carries traffic for multiple VLANs over the same link. The VLANs are multiplexed over the
link with a trunking protocol.
trust boundary When classifying traffic types in an enterprise network, a trust boundary
must be established. The boundary is established by the access device, which either classifies
traffic it allows into the network itself or trusts classification that has already been applied by
an end station, such as an IP phone.
type of service (ToS) A 1-byte field in the IP header used for traffic classification. Specifies
the parameters for the type of service requested. Networks can use the parameters to define
the handling of the datagram during transport.
1439_CCNP_3.book Page 751 Wednesday, October 27, 2004 9:54 AM

Glossary 751

UplinkFast A Catalyst feature that accelerates the choice of a new Root Port when a link or
switch fails.
user VLAN A VLAN created to segment a group of users, either geographically or logically,
from the rest of the network. User VLAN traffic is typically configured to be independent of
VLAN 1, the native VLAN, and the management VLAN.
virtual LAN (VLAN) A group of end stations with a common set of requirements, indepen-
dent of their physical location, that communicate as if they were attached to the same wire. A
VLAN has the same attributes as a physical LAN but allows you to group end stations even if
they are not located physically on the same LAN segment.
Virtual Router Redundancy Protocol (VRRP) Provides functions equivalent to HSRP but
is supported by multiple vendors. It is designed to eliminate a single point of failure that is
unavoidable in static default routing environments.
VLAN access control list (VACL) See VLAN map.
VLAN Management Policy Server (VMPS) A Cisco-proprietary solution for enabling
dynamic VLAN assignments to switch ports within a VTP domain.
VLAN map Also called a VLAN ACL or VACL in the context of Catalyst 6500 switches. It
can filter all traffic traversing a switch. VLAN maps can be configured on the switch to filter
all packets that are routed into or out of a VLAN or that are bridged within a VLAN. VLAN
maps are used strictly for security packet filtering. Unlike router ACLs, VLAN maps are not
defined by direction (input or output).
VLAN Trunking Protocol (VTP) A Cisco-proprietary protocol that uses Layer 2 trunk
frames to communicate VLAN information among a group of Catalyst switches and to man-
age the addition, deletion, and renaming of VLANs across the network from a central point
of control.
VLAN tunneling A technology that allows customers in a metro environment to extend
their logical network topology across wide geographic areas.
VLAN-based SPAN (VSPAN) An analysis of network traffic in one or more VLANs.
VTP domain Also called a VLAN management domain. A network’s VTP domain is the set
of all contiguously trunked switches with the same VTP domain name.
VTP pruning A switch feature used to dynamically eliminate, or prune, unnecessary
VLAN traffic.
1439_CCNP_3.book Page 752 Wednesday, October 27, 2004 9:54 AM

752 Glossary

Weighted Fair Queuing (WFQ) A dynamic scheduling method that provides fair band-
width allocation to all network traffic. WFQ applies priority, or weights, to identified traffic to
classify traffic into conversations and to determine how much bandwidth each conversation is
allowed relative to other conversations. WFQ is a flow-based algorithm that simultaneously
schedules interactive traffic to the front of a queue to reduce response time. It fairly shares the
remaining bandwidth among high-bandwidth flows.
Weighted Random Early Detection (WRED) A mechanism designed to avoid the global
synchronization problems that occur when tail-drop is used as the congestion avoidance
mechanism on the router. WRED is a queuing technique for congestion avoidance. WRED
manages how packets are handled when an interface starts becoming congested. When traffic
begins to exceed the interface traffic thresholds before any congestion, the interface starts
dropping packets from selected flows. If the dropped packets are TCP, the TCP source recog-
nizes that packets are getting dropped and lowers its transmission rate. The lowered trans-
mission rate then reduces the traffic to the interface, avoiding congestion. Because TCP
retransmits dropped packets, no actual data loss occurs.
wire-speed routing The routing of packets using a combination of hardware and data struc-
tures so that routing table lookups are circumvented and header rewrites and forwarding are
handled independent of the route processor.
XTAG A 1-byte value that the MLS-SE attaches per VLAN to all MAC addresses learned
from the same MLS-RP via MLSP.
1439_CCNP_3.book Page 753 Wednesday, October 27, 2004 9:54 AM
1439_CCNP_3.book Page 754 Monday, November 1, 2004 11:16 AM
1439_CCNP_3.book Page 755 Wednesday, October 27, 2004 9:54 AM

Index

Numerics restrictions, 593


10 Gigabit Ethernets, 705–707 router redundancy, 350
standards, 669 security, 598–600. See also security
VLANs, 70 ACLs, 600–602
10BASE-T standards, 702 port ACLs, 604
10-Gigabit EtherChannel, 237 router ACLs, 602–603
3DES (Triple-DES), 589 VLAN ACLs, 604–607
80/20 rule of network traffic, 7–9 switches, 579
802.3 networks, QoS, 484 access control entries (ACEs), 78, 503
access control list. See ACLs
access control policies, 575–576
access layer, 22, 499–508
A
AAA (authentication, authorization, and accounting), accounts
614–634 binding, 587
aaa accounting command, 631 generic users, 586
aaa accounting network command, 633 limiting, 586
aaa authentication command, 622 ACD (automatic call distribution), 399
aaa authentication login command, 623 ACEs (access control entries), 78, 503
aaa authorization command, 626 ACLs (access control lists), 79–92
aaa new-model command, 627 acceleration, 347
accelerating hardware, 347 CEF forwarding, 315
access IP, 507
binding, 587
MAC
console, 710
assigning DSCP values, 502
DTP, 116 configuring DSCPs, 504
in-band management, 581–582 ports, 604
input groups, 90 remote management, 593–594
NAM, 568 routers, 602–603
links, 109–111 security, 610–613
out-of-band management, 579–581 troubleshooting, 89
passwords, 44–45, 582–584 user security, 600–602
PortFast, 178 verification, 87
remote VLANs, 77–78, 604–607
CatOS, 723 AVVID, 392
switch configuration, 46–48 ACS (Cisco Secure Access Control Server), 618
1439_CCNP_3.book Page 756 Wednesday, October 27, 2004 9:54 AM

756 Active Virtual Forwarder (AVF)

Active Virtual Forwarder (AVF), 356 administrative unit (AU), 663


Active Virtual Gateway (AVG), 356 advertisements
adding subset, 137
comments to interfaces, 49 summary, 136
switches, 133 VTP, 134–138
Address Resolution Protocol. See ARP agents, mapping, 439
addresses aggregate policers, 510
BIA, 371 aggregation
CatOS, 723 LACP, 244
globally scoped, 410 metro segmentation, 654
GLOP, 411 NAM, 566–570
IP, 468 PAgP, 242
groups, 440 aging time (MLS), 318
limited scope, 411 algorithms
MAC, 5, 366 STP. See STP
multicast, 408 token buckets, 511
CGMP, 422–424 all keyword, 718
IGMP, 412–422 allocation of bandwidth (CBWFQ), 520–522
Layer 2, 411 all-ports keyword, 107
Layer 3, 409–411 Alternate Port role (RSTP), 187
reserved link local, 410 analysis, 567. See also NAM
virtual, 371 API (application programming interface), 447
adjacency tables, 306, 311 AppleTalk, 34
administration application programming interface (API), 447
AVVID, 394 applications
access control policies, 575–576
in-band, 581–582
AVVID, 388
IP Telephony, 468
campus networks, 9
out-of-band, 579–581
JTAPI, 465
remote
MLS, 294–296
ACLs, 593–594
options, 595–596 multicasting, 408
security, 585–587 CGMP, 422–424
VLANs, 591 configuration, 437–444
scoped addresses, 411 IGMP, 412–422
sessions, 600–602 Layer 2, 411
Layer 3, 409–411
SSH, 587–589
management, 428–429
switches, 38–53
protocols, 432–437
VLANs, 268
routing, 424–427
web interfaces, 592–593
RPF, 430–432
Administrative Trunking Encapsulation, 121 QoS, 458
1439_CCNP_3.book Page 757 Wednesday, October 27, 2004 9:54 AM

bandwidth 757

SDH, 664 authentication, authorization, and accounting (AAA),


SONET, 664 614–634
terminal emulation, 711 authorization
NAM, 568
Application-Specific Integrated Circuits (ASICs), 13, 98
architecture ports, 637
AVVID, 386–401 auto keyword, 638
CEF, 304 automatic call distribution (ACD), 399
automatic load balancing, 31
DFC, 347
Auto-RP configuration, 439
DiffServ, 492
autosensing, 344
IntServ, 491
auxiliary VLANs
metro segmentation, 654
connections, 471
optical networks, 655
IP Telephony implementation, 470
SNA, 34
availability
Supervisor II, 308 AVVID, 390, 393–394
TLS, 655–660 campus networks, 5
ARP (Address Resolution Protocol), 5, 350 CEF, 314
ASICs (Application-Specific Integrated Circuits), 13, 98
high-availability switchovers, 344
assignment
IP
CoS, 501
router redundancy, 350
DSCP values, 502
Telephony, 467
dynamic VLANs, 108
medium campus networks, 34
management interfaces, 724
QoS, 486
memberships, 96–98
AVF (Active Virtual Forwarder), 356
association, packets, 494 AVG (Active Virtual Gateway), 356
Assured Forwarding PHBs, 492 AVVID (Voice, Video, and Integrated Data), 386–396,
asymmetric key pairs, 590 401–405
ATM (Asynchronous Transfer Mode), 14
AVVID, 402
backbone design, 37 B
LANE, 128. See also LANE BackboneFast, STP configuration, 182, 218–219
QoS, 484 backbones
VLANs, 70 ATM design, 37
attaching policies to interfaces, 499 collapsed, 35
attacks, DoS, 203. See also security Layer 2 design, 36
AU (administrative unit), 663 Layer 3 design, 36
authentication scaling, 29–31
AVVID, 392 backup routers, 355. See also routers
IEEE 802.1x port-based, 634–641 bandwidth
NAM, 568 aggregate policers, 510
RSA, 589 CBWFQ, 520, 522
1439_CCNP_3.book Page 758 Wednesday, October 27, 2004 9:54 AM

758 bandwidth

congestion avoidance, 522 guard


LLQ, 526 configuration, 219–220
WRED, 523–526 enhancements, 203
Gigabit Ethernets, 346 RSTP, 194–195
intermetro LAN transports, 652 STP, 172. See also STP
large campus networks, 35–38 Bridge Group Virtual Interface (BVI), 364
modularity, 344 Bridge ID (BID), 158
multicasting, 20 bridge protocol data units (BPDUs), 162
policers, 509 bridges
requirements, 490 Layer 2 switching, 13

scalability, 667 priority, 158

SFM, 570–574 STP, 154. See also STP

unused fiber-optic, 668 table corruption, 154–161

VLANs, 74–75 broadcasts, 73


domains, 5
banners, message-of-the-day, 595
batteries, UPS, 465 loops, 154–156
behavior, switches, 143 multicast addressing, 408
best-effort QoS services, 490–491 storms, 6
BFP (Big Fat Pipe) concept, 666 STP, 154–161
BIA (burned-in Mac address), 371 VLANs, 73
BID (Bridge ID), 158 buffers, history, 53
Big Fat Pipe (BFP) concept, 666 building blocks, campus networks, 23–33
binding access, 587 burned-in MAC address (BIA), 371
Blocking Port role (RSTP), 187 burst-byte, 512
Blocking state (STP), 168 burst-byte option, 511
blocks bus mode, SFM, 571
core, 26 BVI (Bridge Group Virtual Interface), 364
collapsed-core design, 27
dual-core design, 28
switch, 24 C
connections, 38 cable TV (CATV), 662
scaling, 25 cables
bottlenecks, MLS, 294. See also troubleshooting console access, 710
boundaries switches, 38
trust, 459 caches, MLS, 320
VLANs, 93 CallManager
BPDUs (bridge protocol data units) clusters, 451
BackboneFast configuration, 182, 218–219 IP Telephony, 445. See also IP Telephony
exchanges, 162 single servers, 451
formats, 174–175 SMDI support, 404
1439_CCNP_3.book Page 759 Wednesday, October 27, 2004 9:54 AM

Cisco Switched Port Analyzer 759

CAM (Content-Addressable Memory), 297 console access, 710


campus networks. See also networks modes, 712–733
80/20 rules of network traffic, 7–9 terminal emulation, 711
backbones, 29–31 CatOS 4.1(1), 295
building blocks, 23–33 CBT (Core-Based Trees), 427, 435
design CBWFQ (Class-Based WFQ), 519–522, 525
hierarchical models, 20–22 CDP (Cisco Discovery Protocol)
requirements for emerging, 9–10 IP Phones, 469
IOS, 53 SPAN interaction, 548
command-line recall, 53 CEF (Cisco Express Forwarding), 293, 303
help feature, 54–55 adjacency table, 311
idle timeouts, 57 FIB, 309–310
password recovery, 56–57 forwarding, 311–315
large, 35–38 MLS
Layer 1 switching, 262 comparing, 303–307
Layer 2 switching, 13–14 configuration, 315–334
Layer 3 switching, 14–15 operations, 308–309
Layer 4 switching, 15–16 verification, 331
medium, 34 VLANs, 76
multicast, 19–20 central rewrite engines, 303
multilayer switching, 16–17 centralized applications, 9
QoS, 18–19 centralized call processing, 454
services, 10–11 CGMP (Cisco Group Management Protocol), 12, 406,
422–424
small, 34
channel-group command, 249
switch configuration, 38–53
channeling, 12
technology characteristics, 11–12
chassis-based switches, 260
traditional, 4–7
checks, RPF, 430
VLANs, 68. See also VLANs checksums, 15
candidate RPs, 440 circuits
capacity, AVVID, 394 point-to-multipoint TLS, 658
CAR (Committed Access Rate), 512 point-to-point dedicated TLS, 657
classification, 514
Cisco Discovery Protocol. See CDP
policing, 515 Cisco Express Forwarding. See CEF
carrier sense multiple access collision detect (CSMA/CD), Cisco Group Management Protocol. See CGMP
4
Cisco IOS software Release 11.3(2)WA4(4), 295
Catalyst 2926G switches, 295, 317
Cisco IOS software Release 12.0(3c)W5(8a), 295
Catalyst 5000 series switches, 294. See also MLS
Cisco ONS 15327, TLS, 650
Catalyst 6000 series switches, 342
Cisco ONS 15454, TLS, 650
Catalyst 6500 series switches, 570–574
Cisco Secure Access Control Server (ACS), 618
CatOS, 723
Cisco Switched Port Analyzer. See SPAN
configuration, 710
1439_CCNP_3.book Page 760 Wednesday, October 27, 2004 9:54 AM

760 CISCO-RP-DISCOVERY group

CISCO-RP-DISCOVERY group, 440 collapsed core design, 27


Class of Service (CoS) fields, 492 collision domains, 4
Class Selector PHBs, 492 combinations, DTP, 117
Class-based traffic shaping, 528 command-based switches, 40
class-default class, 498 command-line editing/processing, 713
classes command-line interface. See CLI
class-default, 498 command-line recall, 53
llqtraffic, 527 commands, 112, 718, 725
reducedservice, 508 aaa accounting, 631
traffic aaa accounting network, 633
CBWFQ, 519–522 aaa authentication, 622
defining, 495–497 aaa authentication login, 623
classification aaa authorization, 626
CAR, 512 aaa new-model, 627
configuration, 514 aggregate-policier global configuration, 510
QoS at access layer, 499–508 channel-group, 249
traffic, 461 class-map, 495–497
SPAN interaction, 549 clear config all, 719
voice, 459 clear ip route all, 725
clauses, match, 605 clear ip route default gateway, 725
clear config all, 718 configure, 44
clear config all command, 718–719
copy help, 718
clear ip route all command, 725
copy running-configuration startup-configuration, 44
clear ip route default gateway command, 725
crypto key generate rsa, 596
clearing switch configurations, 40–44
debug condition glbp, 360
CLI (command-line interface), 2
clients debug ip icmp, 352
authentication, 635 debug priority, 528
AVVID, 388 debug standby, 378
CGMP, 422–424 debug sw-vlan vtp pruning, 146
RADIUS, 617 delete, 730
VMPS, 105. See also VMPS delete flash.vlan.dat, 43
VTP mode, 133 delete vlan.dat, 133
clusters, CallManager, 451 description, 48
coarse wavelength division multiplexing (CWDM), 667 dir, 730
codecs dot1 x port-control, 637
G.711, 450, 456 dot1 x port-control auto, 635
G.726, 456 duplex {auto | full | half}, 51
G.729, 456 editing, 713
collaboration, AVVID, 404 enable, 41
collapsed backbones, 35 enable secret, 45
1439_CCNP_3.book Page 761 Wednesday, October 27, 2004 9:54 AM

commands 761

encapsulation interface, 269 no channel-group, 249


erase startup-config, 42, 133 no description, 50
exec-timeout, 57 no fabric required, 572
fair-queue interface, 517 no hostname, 46
help, 54, 715–716, 718 no ip address, 48
history, 714 no ip igmp join-group, 443
hostname, 46 no ip igmp snooping vlan, 421
hw-mod module mod reset, 570 no ip igmp version, 444
hw-module mod shutdown, 570 no ip pim send-rp-announce, 440
interface range, 101, 249 no ip pim send-rp-discovery, 441
ip cef, 331 no ip route-cache cef, 331
ip cef distributed, 331 no shutdown, 47, 108
ip http access-class, 593 no shutdown interface, 275
ip http port, 593 no standby group timers, 374
ip http server, 592 no vlan access-map name, 84
ip igmp snooping, 421 no vlan access-map name number, 84
ip irdp, 352 no vtp password, 140
ip multicast-routing, 437 ping, 443
ip pim sparse-dense mode, 437 police, 509
ip pim sparse-mode, 437 police aggregate policy-map configuration, 510
ip routing, 286 policy-map, 497–498
ip rtp header-compression, 538 port group, 249
mac access-list extended name, 503 priority, 527
management, 47 priority bandwidth, 527
match, 84, 495 queue-limit, 527
match-all, 497 random-detect, 524, 527
match class-map, 497 random-detect exponential-weighting-constant, 524
max-reserved-bandwidth percent interface, 522 random-detect precedence, 525
mls qos, 470, 500 reload, 42
mls qos aggregate-policer, 511 rp-announce, 439
mls qos cos default-cos, 501 service password-encryption, 45, 584
mls qos cos override, 501 service-policy, 499
mls qos map policied-dscp, 512 service-policy output policy1, 499
mls qos trust, 470 session module_number, 719
mls ro vlan-id, 316 set enablepass, 720
mls rp ip, 315 set interface sc0, 724
mls rp management-interface, 316 set mls agingtime, 319
mls rp vtp-domain, 316 set mls agingtime fast, 319
no action, 84 set mls disable, 318
1439_CCNP_3.book Page 762 Wednesday, October 27, 2004 9:54 AM

762 commands

set mls enable, 318 show mls rp, 318, 326


set mls flow, 320 show mls rp vtp-domain, 327
set password, 720 show mls status, 328
set system contact, 722 show module, 342, 573, 719
set system location, 722 show monitor session, 560
set system name, 722 show pagp counters, 250
sho fm, 89 show policy-map, 506, 521, 528
show, 521, 572 show port, 733
show access-lists, 81 show port capabilities, 303, 733
show class-map, 505 show port duplex, 733
show config, 720 show port group, 250
show etherchannel, 250 show queue, 521, 525, 528
show etherchannel load-balance, 250 show queuing random-detect, 525
show fabric active, 573 show running-config, 52, 145, 370
show fabric errors, 574 show running-configuration, 51
show fabric status all, 574 show standby, 367, 376
show fabric switching-mode all, 573 show system, 722
show fabric utilization all, 574 show tacacs, 620
show flash, 728 show traffic-shape, 532
show glbp, 360 show traffic-shape statistics, 532
show history, 53 show vlan, 102, 266
show interface, 47, 52 show vlan access-map, 87
show interface interface-id switchport, 145 show vlan filter, 87
show interface switchport, 121 show vmps, 108
show interface trunk, 122 show vtp counters, 142, 146
show ip access-lists, 82 show vtp status, 142
show ip cef, 311, 333 shutdown, 570
show ip cef detail, 310, 331 sow interfaces, 525
show ip cef summary, 333 spanning-tree bpduguard enable, 219
show ip igmp interface, 444 spanning-tree vlan vlan-id root primary, 208–209
show ip interface, 82 speed, 50
show ip interface brief, 282 speed {10 | 100 | 1000 | auto}, 51
show ip pim interface, 438 standby ip, 370
show ip route, 286 standby preempt, 373
show mls, 328 standby track, 376
show mls entry, 330 switchport access vlan, 100, 266
show mls include, 318 switchport access vlan dynamic, 108
show mls qos interface, 506 switchport encapsulation, 113
show mls qos maps policied-dscp, 513 switchport mode access, 101, 116
1439_CCNP_3.book Page 763 Wednesday, October 27, 2004 9:54 AM

configuration 763

switchport mode interface, 115 Compressed Real-Time Transport Protocol (CRTP), 457, 536
switchport mode trunk, 112–113, 117, 119 compression, voice, 457. See also voice
switchport nonegotiate, 119 computer telephony integration (CTI), 399
switchport nonnegotiate, 119 configuration
switchport nonnegotiate interface, 121 802.1x port-based authentication, 639
switchport port-security mac-address, 599 AAA, 614–634
switchport trunk native vlan, 113 ACLs, 610–613
switchport trunk native vlan vlan-id interface, 267 Auto-RP, 439
switchport trunk pruning, 144 CatOS, 710
switchport voice vlan dot1p, 471 console access, 710
modes, 712–733
terminal history size, 54
terminal emulation, 711
traffic-shape adaptive, 531
CBWFQ, 520
traffic-shape fecn-adapt, 531
classification, 514
traffic-shape rate, 531
CoS, 500
trunk, 113
CRTP, 537–538
username Helpdesk privilege 1, 586
default gateways, 725
username name access-class access-list, 587
deleting, 718
username name nopassword, 586
DSCPs, 504
username name privilege level, 586
DTP, 115
username name secret password, 586
EtherChannels, 237–250
username name user-maxlinks number, 586
FEC, 249
vlan database, 138
FRTS, 532
vlan filter, 84
generic user accounts, 586
vtp domain, 140
GTS, 530
vtp mode, 141
hello timers, 374
vtp password, 133, 140
hop counts, 237
vtp pruning, 144
hosts, 352
comments, adding to interfaces, 49
HSRP, 363–378
Committed Access Rate (CAR), 512
idle timeouts, 57
classification, 514
IGMP snooping, 421
policing, 515
inter-VLAN routing, 274
Common Spanning Tree (CST), 195
compact mode, 571 external routers/internal router processors, 276
components native VLANs, 277–279
AVVID, 388 routed ports, 275
router-on-a-stick, 280–282
inter-VLAN routing, 259–261
switch virtual interfaces, 274–275
MLS, 296–300
switched networks, 274
Supervisor Engine II, 308
troubleshooting, 286
uOne Messaging System, 445
verification, 282–286
1439_CCNP_3.book Page 764 Wednesday, October 27, 2004 9:54 AM

764 configuration

ISL, 377 Root guard, 220–221


LLQ, 527 RSTP, 185–195
MLS, 315–334 states, 168–171
MLS-RP, 315, 323 switch, 208–210
MLS-SE, 317 timers, 171–176, 214–216
topology changes, 176–177
MSFCs, 360–361
UplinkFast, 217–218
MST, 232
verification, 225–226
MSTP, 226–237
VLAN, 213
multicast routing, 437–444
Supervisor Engine redundancy, 343
passwords, 44–45, 582–584, 719–721
Switch A, B, and C, 324
PIM verification, 438
switches
policing
campus networks, 38–53
CAR, 515 remote access, 46–48
DSCO map, 512 TACACS+, 620
ports
trunk-connected routers, 271
security, 607–610
usernames, 585
speed, 50, 732
VLANs, 72, 100–102
power supplies, 349
ACLs, 79–92
RADIUS, 620
links, 109–111
Root Switches, 230
maps, 606
routers security, 76–79
native VLANs, 269 trunking, 111–114
redundancy, 349–363 verification, 102–103
RSPAN, 555–556, 558–564 VMPS, 103–108
reflector ports, 556–557 voice, 470
VLANs, 557–558 VMPS, 103–108
RSTP, 226–237 VoIP, 457
saving, 718 VSPAN, 545–546
SFM, 572 VTP, 128–131, 138–146
SPAN, 545–552 adding switches, 133
SSH, 596–598 advertisements, 134–138
STP, 207 modes, 131–133
BackboneFast, 218–219 WRED, 524–525
BPDU guard, 219–220 configure command, 44
default, 207–208 conflicts, ACLs, 89. See also troubleshooting
enabling, 208 congestion
load sharing, 221–225 avoidance, 522
optimization, 177–184 LLQ, 526
Path Cost, 212–213 WRED, 523–526
PortFast, 216–217 loss, 485
priority, 210–212
1439_CCNP_3.book Page 765 Wednesday, October 27, 2004 9:54 AM

customization 765

connections, 653. See also networks; ports core devices, inter-VLAN routing, 262
access control policies, 575–576 core layer, 21
auxiliary VLANs, 471 Core-Based Trees (CBT), 427, 435
campus networks, 4 corruption, 485
console access, 710 CoS (Class of Service) fields, 492, 499
interservice POP, 653 ipphone, 505

inter-VLAN routing, 260 ports, 501

IP Phones, 465 receptionphone, 504

remote management security, 585–587 rewriting, 501

SSH, 598 trust configuration, 500

switches costs
AVVID, 390
blocks, 38
console ports, 38–39 backbones, 31
Ethernet ports, 40 small campus networks, 34
TLS, 650 STP, 159
trunk-connected router configurations, 271 CRC (cyclic redundancy check), 571
connectors CRTP (Compressed Real-Time Transport Protocol), 457,
536
consistency, 128–131
crypto key generate rsa command, 596
adding switches, 133
CSMA/CD (carrier sense multiple access collision
advertisements, 134–138
detect), 4
modes, 131–133 CST (Common Spanning Tree), 195
console access, 710 CTI (computer telephony integration), 399
console messages, 370 customization
console ports, 38–39 802.1x port-based authentication, 639
contacts, CatOS, 722 AAA, 614–634
Content Networking, AVVID, 399
ACLs, 610–613
Content-Addressable Memory (CAM), 297
Auto-RP, 439
controlled load services, 491
CatOS, 710
convergence
console access, 710
AVVID, 386. See also AVVID
modes, 712–733
campus networks, 9
terminal emulation, 711
fast, 30
CBWFQ, 520
STP, 161
classification, 514
decision sequences, 162–163
CoS, 500
steps, 163–168
CRTP, 537–538
copy help command, 718
default gateways, 725
copy running-configuration startup-configuration
command, 44 deleting, 718
copying images, 728 DSCPs, 504
core blocks, 26 DTP, 115
collapsed-core design, 27 EtherChannels, 237–250
dual-core design, 28 FEC, 249
1439_CCNP_3.book Page 766 Wednesday, October 27, 2004 9:54 AM

766 customization

FRTS, 532 routers


generic user accounts, 586 native VLANs, 269
GTS, 530 redundancy, 349–363
hello timers, 374 RSPAN, 555–556, 558–564
hop counts, 237 reflector ports, 556–557
hosts, 352 VLANs, 557–558
HSRP, 363–378 RSTP, 226–237

idle timeouts, 57 saving, 718

IGMP snooping, 421 SFM, 572

inter-VLAN routing, 274 SPAN, 545–552

external routers/internal router processors, 276 SSH, 596–598


native VLANs, 277–279 STP, 207
routed ports, 275 BackboneFast, 218–219
router-on-a-stick, 280–282 BPDU guard, 219–220
switch virtual interfaces, 274–275 default, 207–208
switched networks, 274 enabling, 208
troubleshooting, 286 load sharing, 221–225
verification, 282–286 optimization, 177–184
ISL, 377 Path Cost, 212–213
LLQ, 527 PortFast, 216–217
MLS, 315–334 priority, 210–212
Root guard, 220–221
MLS-RP, 315, 323
RSTP, 185–195
MLS-SE, 317
states, 168–171
MSFCs, 360–361
switch, 208–210
MST, 232
timers, 171–176, 214–216
MSTP, 226–237 topology changes, 176–177
multicast routing, 437–444 UplinkFast, 217–218
passwords, 44–45, 582–584, 719–721 verification, 225–226
PIM verification, 438 VLAN, 213
policing Supervisor Engine redundancy, 343
CAR, 515 Switch A, B, and C, 324
DSCO map, 512 switches
campus networks, 38–53
ports remote access, 46–48
security, 607–610 TACACS+, 620
speed, 50, 732 trunk-connected routers, 271
power supplies, 349 usernames, 585
QoS, 18–19 VLANs, 72, 100–102
RADIUS, 620 ACLs, 79–92
Root Switches, 230 links, 109–111
1439_CCNP_3.book Page 767 Wednesday, October 27, 2004 9:54 AM

design 767

maps, 606 policiers, 512


security, 76–79 policies, 497–498
trunking, 111–114 precedence, 507
verification, 102–103 QoS, 484
VMPS, 103–108 traffic classes, 495–497
voice, 470
delay, 215
VMPS, 103–108
BackboneFast, 182
VoIP, 457
end-to-end networks, 19, 456
VSPAN, 545–546
forwarding, 235
VTP, 128–131, 138–146
packets, 455
adding switches, 133
PortFast configuration, 216–217
advertisements, 134–138
QoS, 485
modes, 131–133
STP updates, 177
WRED, 524–525
delete command, 730
CWDM (coarse wavelength division multiplexing), 667
delete flash vlan.dat command, 43
cyclic redundancy check (CRC), 571
delete vlan.dat command, 133
deleting
configurations, 718
D default gateways, 725
dark fiber, AVVID, 402
images, 730
data, QoS, 487
Data Encryption Standard (DES), 589 maps, 84
data terminal equipment (DTE), 531 RSPAN, 561
DB-9-to-RJ-45 serial adapters, 711 SPAN sessions, 551
debug condition glbp command, 360 VLANs, 102, 113
debug ip icmp command, 352 delivery
debug priority command, 528 multicast packets, 442
debug standby command, 378 multicast trees, 432–437
debug sw-vlan vtp pruning command, 146 Denial of Service (DoS) attacks, 203
decision sequences (STP), 162–163 dense-mode routing protocols, 432. See also protocols
DECnet, 34 deny keyword, 84
dedicated circuits, point-to-point TLS, 657 deployment
default behavior, switches, 143 MLS, 294. See also MLS
NAM, 566–570
default gateways DES (Data Encryption Standard), 589
configuration, 725 description command, 48
redundant router access, 350 descriptors, ports, 731
default STP configurations, 207–208 design
default timers, 214–216 802.1x port-based authentication, 639
default VLANs, 265 AAA, 614–634
defining ACLs, 610–613
DSCPs, 507
1439_CCNP_3.book Page 768 Wednesday, October 27, 2004 9:54 AM

768 design

Auto-RP, 439 switch virtual interfaces, 274–275


AVVID, 394 switched networks, 274
backbones, 37 troubleshooting, 286
campus networks verification, 282–286
hierarchical models, 20–22 IP Telephony, 450–454
medium, 34 ISL, 377
multicast, 19 large campus networks, 35–38
QoS, 18–19 Layer 2 backbones, 36
requirements for emerging, 9–10 Layer 3 backbones, 36
small, 34 LLQ, 527
CatOS, 710 MLS, 315–334
console access, 710 MLS-RP, 315, 323
modes, 712–733 MLS-SE, 317
terminal emulation, 711 MSFCs, 360–361
CBWFQ, 520
MST, 232
classification, 514
MSTP, 226–237
collapsed core, 27
multicast routing, 437–444
CoS, 500
passwords, 44–45, 582–584, 719–721
CRTP, 537–538
PIM verification, 438
default gateways, 725
policing
deleting, 718
CAR, 515
DSCPs, 504 DSCO map, 512
DTP, 115 ports
dual-core, 28 security, 607–610
EtherChannels, 237–250 speed, 50, 732
FEC, 249 power supplies, 349
FRTS, 532 RADIUS, 620
generic user accounts, 586 Root Switches, 230
GTS, 530 routers
hello timers, 374 native VLANs, 269
hop counts, 237 redundancy, 349–363
hosts, 352 RSPAN, 555–556, 558–564
HSRP, 363–378 reflector ports, 556–557
idle timeouts, 57 VLANs, 557–558
IGMP snooping, 421 RSTP, 226–237
inter-VLAN routing, 274 saving, 718
external routers/internal router processors, 276 SFM, 572
native VLANs, 277–279 SPAN, 545–552
routed ports, 275 SSH, 596–598
router-on-a-stick, 280–282
1439_CCNP_3.book Page 769 Wednesday, October 27, 2004 9:54 AM

distribution 769

STP, 207 VTP, 128–131, 138–146


BackboneFast, 218–219 adding switches, 133
BPDU guard, 219–220 advertisements, 134–138
default, 207–208 modes, 131–133
enabling, 208 WRED, 524–525
load sharing, 221–225 Designated Ports parameters
optimization, 177–184 RSTP, 188
Path Cost, 212–213 STP, 166–168
PortFast, 216–217 designated router (DR) selection, PIM configuration, 438
priority, 210–212 desirable mode, DTP, 117
Root guard, 220–221 destination multicast addresses, 408
RSTP, 185–195 destination-ip flow mask, 297
states, 168–171 deterministic paths, campus networks, 9
switch, 208–210 devices
timers, 171–176, 214–216 CEF support on, 306
topology changes, 176–177 IGMP membership reports, 414
UplinkFast, 217–218
power supply redundancy, 348–349
verification, 225–226
DFCs (distributed forwarding cards), 347
VLAN, 213
DHCP (Dynamic Handshake Challenge Protocol),
Supervisor Engine redundancy, 343 350–351
Switch A, B, and C, 324 diameter keyword, 210
switches Differentiated Services Code Point. See DSCP
campus networks, 38–53 Differentiated Services Monitoring (DSMON), 568
remote access, 46–48 DiffServ, QoS, 492
TACACS+, 620 digital subscriber line (DSL), 402
trunk-connected routers, 271 dir command, 730
usernames, 585 disabling
VLANs, 72, 100–102 Auto-RP, 440
ACLs, 79–92 STP, 208
links, 109–111 Distance Vector Multicast Routing Protocol (DVMRP),
maps, 606 407, 432
security, 76–79 distributed call processing, 452–453
trunking, 111–114 distributed forwarding cards (DFCs), 347
verification, 102–103 distribution
VMPS, 103–108 broadcasts, 73
voice, 470 CGMP, 425
VMPS, 103–108 frames, 240
voice, 465–472 layers, 21
VoIP, 457 MDF, 75, 95
VSPAN, 545–546 RPF, 430–432
1439_CCNP_3.book Page 770 Wednesday, October 27, 2004 9:54 AM

770 domains

domains edge ports, 187


broadcast, 5, 73 editing, command-line, 713
collision, 4 efficiency, link mechanisms, 534
VTP, 102 ELANs (Emulated LANs), 123
adding switches, 133 elements, campus networks, 23–33
configuration, 140 emerging campus network design, 9–10
DoS (denial of Service) attacks, 203 EMI (Enhanced Multilayer Image), 77
dot1x port-control auto command, 635 Emulated LANs (ELANs), 123
dot1x port-control command, 637 emulation, LANE, 123, 127–128
DPT (Dynamic Packet Transport), 665 enable command, 41
DR (designated router) selection, PIM configuration, 438 enable secret command, 45
dropped packets, 515, 522–526 enabling
DSCP (Differentiated Services Code Point), 463, 492 AAA, 627
defining, 507 BPDU guard, 219
limitations, 520 IRDP processing, 352
MAC ACL configuration, 504 MSTP, 228
maps, 512 passwords, 720
QoS level applications, 494 RSTP, 228
values, 502 STP, 208
DSL (digital subscriber line), 402 encapsulation
DSMON (Differentiated Services Monitoring), 568 Administrative Trunking Encapsulation, 121
DTE (data terminal equipment), 531 VLANs, 123, 128
DTP (Dynamic Trunking Protocol), 101, 114–121 encapsulation interface command, 269
dual Supervisor Engines, 342. See also Supervisor Engines encryption, 45
duplex, 50, 732 key pairs, 589–591
duplex {auto | full | half} command, 51 NAM, 568
DVMRP (Distance Vector Multicast Routing Protocol), passwords, 586, 720
407, 432
SSH, 587–589
Dynamic Handshake Challenge Protocol (DHCP),
end stations, 68
350–351
end-to-end availability, 393–394
Dynamic Packet Transport (DPT), 665
end-to-end latency, 75–76
dynamic packet transports, 666
end-to-end network delay, 19, 456
dynamic port VLAN membership, 104
end-to-end VLANs, 94–95. See also VLANs
dynamic routing protocols, 350–351
enforcing policies, 515
Dynamic Trunking Protocol (DTP), 101, 114–121
Enhanced Multilayer Image (EMI), 77
dynamic VLANs, 98–99, 108. See also VLANs
Enhanced PVST+, 198
enhancements
802.1x port-based authentication, 639
E AAA, 614–634
EAPOL (Extensible Authentication Protocol over LAN), 635
echoes, 457. See also voice ACLs, 610–613
1439_CCNP_3.book Page 771 Wednesday, October 27, 2004 9:54 AM

enhancements 771

Auto-RP, 439 MSTP, 226–237


CatOS, 710 multicast routing, 437–444
console access, 710 passwords, 44–45, 582–584, 719–721
modes, 712–733 PIM verification, 438
terminal emulation, 711 policing
CBWFQ, 520 CAR, 515
classification, 514 DSCO map, 512
CoS, 500 ports
CRTP, 537–538 security, 607–610
default gateways, 725 speed, 50, 732
deleting, 718 power supplies, 349
DSCPs, 504 QoS, 18–19
DTP, 115 RADIUS, 620
EtherChannels, 237–250 Root Switches, 230
FEC, 249 routers
FRTS, 532 native VLANs, 269
generic user accounts, 586 redundancy, 349–363
GTS, 530 RSPAN, 555–556, 558–564
hello timers, 374 reflector ports, 556–557
hop counts, 237 VLANs, 557–558
RSTP, 226–237
hosts, 352
saving, 718
HSRP, 363–378
SFM, 572
idle timeouts, 57
SPAN, 545–552
IGMP snooping, 421
SSH, 596–598
inter-VLAN routing, 274
STP, 207
external routers/internal router processors, 276
native VLANs, 277–279 BackboneFast, 218–219
routed ports, 275 BPDU guard, 219–220
router-on-a-stick, 280–282 default, 207–208
switch virtual interfaces, 274–275 enabling, 208
switched networks, 274 load sharing, 221–225
troubleshooting, 286 optimization, 177–184
verification, 282–286 Path Cost, 212–213
ISL, 377 PortFast, 216–217
priority, 210–212
LLQ, 527
Root guard, 220–221
MLS, 315–334
RSTP, 185–195
MLS-RP, 315, 323
states, 168–171
MLS-SE, 317
switch, 208–210
MSFCs, 360–361 timers, 171–176, 214–216
MST, 232
1439_CCNP_3.book Page 772 Wednesday, October 27, 2004 9:54 AM

772 enhancements

topology changes, 176–177 autosensing, 344


UplinkFast, 217–218 DTP, 114–120
verification, 225–226 Fast Ethernets. See Fast Ethernets
VLAN, 213 fiber-optic transports, 660–671
Supervisor Engine redundancy, 343 Gigabit
Switch A, B, and C, 324 10, 705–707
switches standards, 702–705
campus networks, 38–53 inter-VLAN routing, 260
remote access, 46–48 metro services, 655
TACACS+, 620 ports, 40
trunk-connected routers, 271 QoS, 484
usernames, 585 TLS solutions, 649–655
VLANs, 72, 100–102 exceed-action options, 512
ACLs, 79–92 exchanges, BPDUs, 162
links, 109–111 EXCLUDE mode (IGMPv3), 419
maps, 606 exec-timeout command, 57
security, 76–79 Expedited Forwarding PHBs, 492
trunking, 111–114 Extensible Authentication Protocol over LAN
verification, 102–103 (EAPOL), 635
VMPS, 103–108 external network security, AVVID, 392
voice, 470 external patch panel power, IP Phones, 466
VMPS, 103–108 external routers, inter-VLAN routing, 276
VoIP, 457
VSPAN, 545–546
VTP, 128–131, 138–146 F
adding switches, 133 fair-queue interface command, 517
advertisements, 134–138 farms, servers, 8
modes, 131–133 fast convergence, 9, 30
WRED, 524–525 Fast EtherChannel (FEC), 237, 249
enterprise services, 10 Fast Ethernets
equal-cost path load balancing, 306 inter-VLAN routing, 260
erase startup-config command, 42 VLANs, 70
erase startup-config commands, 133 fast switchovers, 344
errors, loss, 485. See also troubleshooting FCS (frame check sequence), 125
EtherChannels FDDI (Fiber Distributed Data Interface), 14
configuration, 237–250 FEC (Fast EtherChannel), 237, 249
NAM, 569 feedback, echoes, 457. See also voice
RSPAN interaction, 557 FIB (Forward Information Base), 306–310
SPAN interaction, 548 Fiber Distributed Data Interface (FDDI), 14
fiber exhaustion, 667
Ethernets
fiber infrastructures, 669
10GbE standards, 669
1439_CCNP_3.book Page 773 Wednesday, October 27, 2004 9:54 AM

generic user accounts, creating 773

fiber-optic transports, 660–671 STP, 178


fields VLANs, 69
CoS, 492, 499 Forwarding Information Base (FIB), 306–310
RIF, 174 Forwarding state (STP), 170
show module status, 348 frame check sequence (FCS), 125
ToS, 492 Frame Relay, 22
FIFO (first in, first out) queues, 516 AVVID, 402
filtering QoS, 484
packets, 600–602 Frame Relay Traffic Shaping (FRTS), 528, 531
source, 418 frames
VLANs, 562 BPDUs, 174–175
filters, 83 CGMP, 424
firewalls, AVVID, 392. See also security distribution, 240
first-hop failures, 350–354 loss, 485
Flash memory, loading images to, 726 SPAN, 546
flexibility, AVVID, 390 STM, 663
flooding VLANs, 122–123
DVRMP, 433 IEEE 802.10 protocol, 126–127
multicast traffic, 407 IEEE 802.1Q protocol, 125–126
flow, 17 ISL, 123–125
masks, 297, 319 LANE, 127–128
MLS, 297 frameworks, AVVID, 386
packets, 311–315 FRTS (Frame Relay Traffic Shaping), 528
traffic, 495, 528–533
WFQ, 516–518
force-authorized keyword, 637 G
force-unauthorized keyword, 638 G.711 codecs, 450, 456
formats, BPDUs, 174–175. See also configuration G.726 codecs, 456
forwarders, types of, 356 G.729 codecs, 456
forwarding, 215 Gateway Load Balancing Protocol (GLBP), 356–360
CEF, 306, 76 gateways
delay, 215, 235 configuration, 725
DFCs, 347 redundant router access, 350
distribution trees, 425 types of, 356
high-speed, 306 video, 405
metro segmentation, 654 GBIC (Gigabit Interface Converter), 51, 308, 345
PortFast configuration, 216–217 GEC (Gigabit EtherChannel), 237
Generic Routing Encapsulation (GRE), 347
RPF, 430. See also RPF
Generic Traffic Shaping. See GTS
RSTP, 191
generic user accounts, creating, 586
1439_CCNP_3.book Page 774 Wednesday, October 27, 2004 9:54 AM

774 Gigabit EtherChannel (GEC)

Gigabit EtherChannel (GEC), 237 MLS, 294–296


Gigabit Ethernets redundancy, 342
10, 705–707 AVVID, 394
fiber-optic transports, 660–671 DFCs, 347
inter-VLAN routing, 260 modularity, 344–346
services, 650 power, 348–349
standards, 702–705 routers, 349–363
VLANs, 70 Supervisor Engines, 342–344
Gigabit Interface Converter. See GBIC headers, RIF, 174
GLBP (Gateway Load Balancing Protocol), 356–360 hello messages, HSRP, 373
global synchronization, 522 hello time
globally scoped addresses, 410 keywords, 210
GLOP addresses, 411 MSTP, 235
GRE (Generic Routing Encapsulation), 347 help. See also troubleshooting
groups command, 54, 715–718
CISCO-RP-DISCOVERY, 440 IOS, 54–55
EtherChannels, 245 hierarchical models, campus networks, 20–22
multicasting, 442 high availability
multiple HSRP, 364 AVVID, 390, 393–394
networks, 70 IP
RPs, 440 router redundancy, 350
VRRP, 355–356 Telephony, 467
switchovers, 344
GTS (Generic Traffic Shaping), 528–529
configuration, 530 high-speed forwarding, 306
high-speed interconnections, 653
verification, 532
history
guaranteed rate services, 491
buffers, 53
guards
commands, 714
BPDU configuration, 219–220
of Gigabit Ethernet standards, 702
Root configuration, 220–221
hop count configuration, 237
hostname command, 46
hosts
H access, 178
handling delay, 456
hardware IGMP, 412–422
acceleration, 347 IRDP, 352
devices. See devices VLANs, 68
GLBP, 357 HSRP (Hot Standby Router Protocol), 12, 352–354
Layer 2 switching, 13 HTTP (Hypertext Transfer Protocol) restrictions, 593
HTTPS (HTTP over Secure Socket Layer), 568
Layer 3, 14
hubs, campus networks, 4
Layer 4, 15
1439_CCNP_3.book Page 775 Wednesday, October 27, 2004 9:54 AM

interaction, SPAN 775

hw-mod module mod reset command, 570 implementation. See also configuration
hw-mod module mod shutdown command, 570 AVVID, 401–405
HyperTerminal, 40, 711 QoS, 457
redundancy, 342
DFCs, 347
I modularity, 344–346
IANA (Internet Assigned Numbers Authority), 410 power, 348–349
ICMP Router Discovery Protocol (IRDP), 12, 352 routers, 349–363
identification (VLANs), 122–123 Supervisor Engines, 342–344
IEEE 802.10 protocol, 126–127 SONET/SDH, 664
IEEE 802.1Q protocol, 125–126 VLANs
ISL, 123–125 ACLs, 79–92
LANE, 127–128 security, 76–79
identifiers, Port Numbers parameter (STP), 161 in-band management, 581–582
identifying individual ports, 48–52 inbound-accesslayer policy, 506
identities, AVVID, 392 INCLUDE mode (IGMPv3), 419
idle timeouts, 57 independent call processing, 451
IDs (identifications) individual policers, 509
BID, 158 individual ports, identifying, 48–52
port ID parameter (STP), 160 infrastructure
IDSs (intrusion detection systems), 392. See also security AVVID, 386–401
IEEE 802.10 protocol, 126–127 IP Telephony, 467
IEEE 802.10 standard, transporting VLANs, 123 PKI, 589
IEEE 802.1Q protocol, 94, 125–126 TLS solutions, 650
IEEE 802.1w RSTP, 185–195 infrastructures, fiber, 669
IEEE 802.1x port-based authentication, 634–641 initiation, authentication, 635
IEEE 802.3ab, 703 inline power, IP Phones, 466
IEEE 802.3z standard, 704 inline rewrites, 303
IGMP (Internet Group Management Protocol), 12, input access groups, merge failures, 90
412–422 integrated data
snooping, 407 AVVID, 386–401
versions, 443 implementation, 401–405
IGMP Version 1 (IGMPv1), 412 integrated route processors, Inter-VLAN routing
IGMP Version 2 (IGMPv2), 415 configuration, 270
IGMP Version 3 (IGMPv3), 418 integration
images CTI, 399
copying, 728 NAM, 569
deleting, 730 route processors, 260
Flash memory, 726 Intelligent Network Services, AVVID, 391–392
reordering, 730 interaction, SPAN, 548–549
1439_CCNP_3.book Page 776 Wednesday, October 27, 2004 9:54 AM

776 interactive voice response (IVR)

interactive voice response (IVR), 388 web management security, 592–593


interface keyword, 52 WFQ, 517
interface range command, 101, 249
WRED configuration, 524
interfaces, 443
intermetro LAN transports, 652
API, 447
internal MSFC redundancy, 361
BVI, 364
internal network security, AVVID, 392. See also security
CBWFQ configuration, 521 internal route processors, 276
CLI, 2 Internet, 8
comments, 49 Internet Assigned Numbers Authority (IANA), 410
DTP, 114–120 Internet Group Management Protocol (IGMP), 12, 407
FIFO queues, 516 Internet Protocol. See IP
GBICs, 51, 345 interoperability
AVVID, 390
GTS configuration, 530
IGMP, 417
HSRP, 375
VRRP, 355–356
IGMP version modification, 443
interservice POP connectivity, 653
inter-VLAN routing, 263–265
Inter-Switch Link (ISL), 94, 123–125, 377
JTAPI, 465
inter-VLAN routing configuration, 274
management external routers/internal router processors, 276
assigning, 724 methods, 259
MLS-RP, 316 components, 259–261
MQC, 495 core device redundancy, 262
multicast, 438 Layer 3 feature cards, 273
NAM Traffic Analyzer, 569 route switch processors, 269–270
native VLAN configuration, 269 router-on-a-stick, 271–272
optical networks, 660 scalability, 263–265
PNNI, 37 types of, 265–269
native VLANs, 277–279
policies
routed ports, 275
attaching, 499
binding, 507 router-on-a-stick, 280–282
maps, 508 switch virtual interfaces, 274–275
port ACLs, 604 switched networks, 274
router ACLs, 602–603 troubleshooting, 286
SMDI, 403 verification, 282–286
SVIs, 79 intrusion detection systems (IDSs), 392. See also security
switch virtual configuration, 274–275 IntServ, QoS, 491
traffic shaping, 528–533 invalidation of routes, 306
IOS
VLANs
campus networks, 53
ACLs, 604
command-line recall, 53
configuration, 102–103
1439_CCNP_3.book Page 777 Wednesday, October 27, 2004 9:54 AM

LANs (local access networks) 777

help feature, 54–55 IP-routed networks, QoS, 484


idle timeouts, 57 IPv6 (Internet Protocol version 6), 347
password recovery, 56–57 IRDP (ICMP Router Discovery Protocol), 12, 352
CoS configuration, 500 ISL (Inter-Switch Link), 94, 123–125, 377
IP (Internet Protocol) isolation, VLANs, 72
ACLs, 507 IVR (interactive voice response), 388
MLS flow masks, 319
precedence, 494
router redundancy, 350 J
ip cef command, 331 jitter, 456, 485
ip cef distributed commands, 331 joining multicast groups, 442
IP Contact Center (IPCC), 399 JTAPI (Java Telephony Application Programming
Interface), 465
ip http access-class command, 593
ip http port command, 593
ip http server command, 592
ip igmp snooping command, 421 K
Kerberos, 615
ip irdp command, 352
keys, encryption, 589–591
IP MLS operation, 321
keywords
ip multicast-routing command, 437
accounting, 632
IP networks, 387
IP Phones all, 718
CDP, 469 all-ports, 107
physical connections, 465 auto, 638
power, 466 deny, 84
ip pim sparse-dense-mode command, 437 diameter, 210
ip pim sparse-mode command, 437 exceed-action drop, 512
IP Precedence, 464, 518 exceed-action policied-dscp-transmit, 512
ip routing command, 286 force-authorized, 637
ip rtp header-compression command, 538 force-unauthorized, 638
IP Telephony, 444–449 hello-time, 210
AVVID, 395 interface, 52
design, 450–454 log, 315
high availability, 467 permit, 84
infrastructure, 467 statistics, 108
power/protection options, 465
VLANs, 470
IP videoconferencing, 396 L
IP+Optical, 656–657 LACP (Link Aggregation Control Protocol), 244
IPCC (IP Contact Center), 399 LAN Emulation (LANE), 123, 127–128
ip-flow flow mask, 297 LANs (local access networks)
ipphone CoS, 505 campus networks, 4
1439_CCNP_3.book Page 778 Wednesday, October 27, 2004 9:54 AM

778 LANs (local access networks)

ELANs, 123 OSI, 12


LANE, 123, 127–128 PDUs, 12
NAM, 566–570 physical, 391
TLS, 649 Learning state (STP), 169
VLANs, 67 leave group messages, IGMP, 408
large campus networks, 35–38 legacy migration, AVVID, 403, 405
LAT (local-area transport), 631 legacy networks, VLANs, 70–71
latency LFI (Link Fragmentation and Interleaving), 534
QoS, 485 limitations
routers, 75–76 of bandwidth
voice, 458 aggregate policers, 510
Layer 1 inter-VLAN routing, 262 policers, 509
Layer 2 of DSCPs, 520
backbones of sessions, 586
design, 36 of SPAN configuration, 549
scaling, 29–31 of VLANs, 68
forwarding, 311–315 limited scope addresses, 411
inter-VLAN routing, 262 line cards, 347
multicast addressing, 411 line modes
resiliency, 28 configuration, 50
switching, 13–14 defining, 50
traffic classification, 462 line passwords, 584
Link Aggregation Control Protocol (LACP), 244
VLANs, 69
Link Fragmentation and Interleaving (LFI), 534
Layer 3
links
backbones
automatic load balancing, 31
design, 36
ISL, 123–125
scaling, 29–31
local addresses, 410
feature cards, 273
low-speed (QoS), 533–538
forwarding, 311–315
trunking, 377
MLS, 294
UplinkFast, 180, 217–218
multicast addressing, 409–411
VLANs, 109–114
performance, 31
Listening state (STP), 169
switching, 14–15
LLQ (Low Latency Queuing),19, 526
traffic classification, 463
llqtraffic class, 527
Layer 4 switching, 15–16
load balancing, automatic, 31
layers
load sharing, 202
access, 22
configuration, 221–225
core, 21
paths, 306
distribution, 21
STP, 201
large campus networks, 35–38
1439_CCNP_3.book Page 779 Wednesday, October 27, 2004 9:54 AM

match command 779

loading images to Flash memory, 726 management


local access networks. See LANs AVVID, 394
local forwarding, 347 delivery of multicast packets, 428–429
local services, campus networks, 10 in-band, 581–582
local VLANs, 95–96. See also VLANs interfaces
local-area transport (LAT), 631 assigning, 724
locations, CatOS, 722 MLS-RP, 316
log keyword, 315 IP Telephony, 468
logging passwords, 44–45
medium campus networks, 34
login, passwords, 720
NAM, 566–570
longest address match lookups, 306
out-of-band, 579–581
loop-free logical topologies, 162–168
remote
loops, 156
broadcast, 154 ACls, 593–594
options, 595–596
physical, 154
security, 585–587
spanning-tree, 29
VLANs, 591
STP, 208
sessions, 600–602
loss
SSH, 587–589
QoS, 485
Supervisor Engine redundancy, 342–344
traffic shaping, 528–533
switches, 38–53
lost packets, 455
VLANs, 268
Low Latency Queuing. See LLQ
web interfaces, 592–593
low-speed links, QoS, 533–538
management command, 47
maps
agents, 439
M deleting, 84
MAC (Media Access Control), 5
ACLs DSCPs, 512
assigning DSCP values, 502 MAC VLAN, 80
configuring DSCPs, 504 policy
addresses applying to interfaces, 508
BIA, 371 creating, 514
virtual, 371 VLAN, 79, 604–607
virtual routers, 366 marking traffic, 492, 509–516
mac access-list extended name command, 503 masks
MAC VLAN maps, 80 flow, 297
Main Distribution Facility (MDF), 75, 95 IP MLS, 319
MANs (metropolitan access networks) master routers, 355. See also routers
DWDM, 667 match class-map command, 497
SONET/SDH implementations, 664 match clauses, 605
match command, 84, 495
1439_CCNP_3.book Page 780 Wednesday, October 27, 2004 9:54 AM

780 match-all command

match-all command, 497 methods


match-any option, 497 encapsulation, 123
maximum aging time EtherChannels, 241
MSTP, 236 inter-VLAN routing, 259
VLANs, 215 components, 259–261
maximum hop count configuration, 237 core device redundancy, 262
max-reserved-bandwidth percent interface command, 522 Layer 3 feature cards, 273
MBONE (multicast backbone), 433 route switch processors, 269–270
MDF (Main Distribution Facility), 75, 95 router-on-a-stick, 271–272
mechanisms (QoS), 490 scalability, 263–265
best-effort, 490–491 types of, 265–269
class-map command, 495–497 metro Ethernet services, 655
DiffServ, 492 metro segmentation, 654
IntServ, 491 metropolitan access networks. See MANs
MQC, 495 Microsoft NetMeeting, AVVID, 404
policy-map command, 497–498 migration
AVVID, 388, 403
service-policy command, 499
modularity, 344
traffic marking, 492–495
mirroring VLANs, 562
media, 388. See also AVVID
MISTP (Multiple Instances of Spanning Tree Protocol),
Media Access Control. See MAC
198
medium campus networks, 34
MISTP-PVST+ mode, 199
membership
MLS (Multilayer Switching), 16–17, 293
dynamic ports, 104
aging time, 318
IGMP, 408, 414
CEF
VLANs, 96–98
comparing, 303–307
memory
configuration, 315–334
CAM, 297
components, 296–300
Flash, 726
flows, 297
NVRAM, 719
hardware/software requirements, 294–296
merge failures, input access groups, 90
IP flow masks, 319
message-of-the-day banner, 595
operations, 300–303
messages
verification, 326
console, 370
mls qos aggregate-policer command, 511
hello, 373
mls qos command, 470, 500
HSRP, 352, 368
mls qos cos default-cos command, 501
IGMP, 408, 412–422
mls qos cos override command, 501
refuse, 596 mls qos map policed-dscp command, 512
remote management sessions, 595–596 mls qos trust command, 470
vacant, 596 mls rp ip command, 315
VTP, 130 mls rp management-interface command, 316
1439_CCNP_3.book Page 781 Wednesday, October 27, 2004 9:54 AM

multicasting 781

mls rp vlan-id command, 316 RSPAN, 555–556


mls rp vtp-domain command, 316 configuration, 558–564
MLS Switching Engine (MLS-SE), 296 reflector ports, 556–557
MLSP (Multilayer Switching Protocol), 297 VLANs, 557–558
MLS-RP (Multilayer Switching Route Processor), 295, SFM, 570–574
315, 323 SPAN, 545–546
MLS-SE (MLS Switching Engine), 296, 317
configuration, 549–552
models
interaction, 548–549
OSI, 5
port basis, 546
QoS, 490 sources, 552–554
best-effort, 490–491 VSPAN, 545–546
class-map command, 495–497 Mono Spanning Tree (MST), 197, 199
DiffServ, 492 mono spanning tree modes, 195–207
IntServ, 491 MOSPF (Multicast Open Shortest Path First), 432
MQC, 495 moving images, 728
policy-map command, 497–498 MPLS (Multiprotocol Label Switching), 347
service-policy command, 499 MQC (Modular QoS command-line interface), 495
traffic marking, 492–495 MSDP (Multicast Source Discovery Protocol), 20
modes MSFC (Multilayer Switch Feature Card), 273, 295,
CatOS, 712–733 360–361
DTP, 115 MSFC2 (Multilayer Switching Feature Card 2), 308
LACP, 244 MSM (Multilayer Switch Module), 295
lines, 50 MST (Multiple Spanning Tree), 199
MISTP-PVST+, 199 Path Cost default values, 232
mono spanning tree, 195–207 Port Priority, 234
PAgP, 242 Root Switches, 230
transparent, 130 mulitlink PPP, LFI, 535
VTP, 131–133, 141 multicast backbone (MBONE), 433
modification Multicast Open Shortest Path First (MOSPF), 432, 434
HSRP state, 370 Multicast Source Discovery Protocol (MSDP), 20
multicasting, 406
modes, 712–733
addressing, 408
of IGMP versions, 443
CGMP, 422–424
STP
IGMP, 412–422
default timers, 214–216
Layer 2, 411
root switches, 208–210
Layer 3, 409–411
topologies, 176–177
AVVID, 394
modularity, Supervisor Engine redundancy, 344–346
campus networks, 10, 19–20
CEF forwarding, 315
monitoring
DVRMP, 407
NAM, 566–570
groups, 442
RMON, 567. See also RMON
1439_CCNP_3.book Page 782 Wednesday, October 27, 2004 9:54 AM

782 multicasting

PIM, 394, 407 native VLANs, 113, 266. See also VLANs
routing, 424–427 configuration, 269
configuration, 437–444 routers, 277–279
management, 428–429 NDE (NetFlow Data Export), 317
protocols, 432–437 NDIS (network driver interface specification), 128
RPF, 430–432 Negotiation of Trunking, 121
traffic, 549 neighbors, PIM, 439
Multilayer Switch Feature Card (MSFC), 273, 295, NetFlow, 306
360–361 NetFlow Data Export (NDE), 317
Multilayer Switch Module (MSM), 295 NetFlow Feature Card (NFFC), 294, 303
Multilayer Switching Feature Card 2 (MSFC2), 308 Network Analysis Module (NAM), 545, 564–570
Multilayer Switching Protocol (MLSP), 297 network driver interface specification (NDIS), 128
Multilayer Switching Route Processor (MLS-RP), 295 Network Management Processor (NMP), 308
Multilayer Switching. See MLS Network Time Protocol (NTP), 410, 593
multimedia, 73. See also AVVID networks
multiple default gateways, 350 access control policies, 575–576
multiple HSRP groups, 364 auxiliary VLAN connections, 471
Multiple Instances of Spanning Tree Protocol (MISTP), AVVID, 386–401
198
campus, 4–7. See also campus networks
multiple links, 31
capacity, 394
multiple NAMs, 569. See also NAM
identities, 392
multiple physical interfaces, 443. See also interfaces
multiple RPs, 439 IP Telephony design, 450–454
multiple sites model, IP Telephony, 451 metro, 654
Multiple Spanning Tree. See MST multicasting, 406
multiplexing addressing, 408
CWDM, 667 CGMP, 422–424
optical networks, 663 configuration, 437–444
Multiprotocol Label Switching (MPLS), 347 IGMP, 412–422
multiprotocol support, campus networks, 10 Layer 2, 411
multi-service QoS models (IntServ), 491 Layer 3, 409–411
multisite IP WANs management, 428–429
centralized call processing, 454 protocols, 432–437
distributed call processing, 452–453 routing, 424–427
RPF, 430–432
optical transports, 660–671
security, 76, 577
N
NAM (Network Analysis Module), 545, 564–570 SONET, 660
names VLANs. See VLANs
CatOs, 722
NFFC (NetFlow Feature Card), 294, 303
switches, 46 NMP (Network Management Processor), 308
usernames, 585
1439_CCNP_3.book Page 783 Wednesday, October 27, 2004 9:54 AM

optimization 783

no action command, 84 optical networks


no channel-group command, 249 architecture, 655
no description command, 50 transports, 660–671
no fabric required command, 572 optical STS cores, 658
no hostname command, 46 optimization
no ip address command, 48 802.1x port-based authentication, 639
no ip igmp join-group commands, 443 AAA, 614–634
no ip igmp snooping vlan command, 421 ACLs, 610–613
no ip igmp version command, 444
Auto-RP, 439
no ip pim send-rp-announce command, 440
CatOS, 710
no ip pim send-rp-discovery command, 441
console access, 710
no ip route-cache cef command, 331
modes, 712–733
no shutdown command, 47, 108
terminal emulation, 711
no shutdown interface command, 275
CBWFQ, 520
no standby group timers command, 374
classification, 514
no vlan access-map name command, 84
no vlan access-map name number command, 84 CoS, 500
no vtp password command, 140 CRTP, 537–538
noise, 5 default gateways, 725
nonblocking backplanes, 12 deleting, 718
nonredundant configurations, power supplies, 349 DSCPs, 504
nontrunking, 121 DTP, 115
nonvolatile random-access memory (NVRAM), 719 EtherChannels, 237–250
Novell IPX, 34 FEC, 249
NTP (Network Time Protocol), 410, 593 FRTS, 532
NVRAM (nonvolatile random-access memory), 719
generic user accounts, 586
GTS, 530
hello timers, 374
O hop counts, 237
ODI (Open Data-Link Interface), 128
hosts, 352
one-way latency, voice, 458
Open Data-Link Interface (ODI), 128 HSRP, 363–378
Open System Interconnection. See OSI idle timeouts, 57
operating telephone company (OTC) optical networks, 660 IGMP snooping, 421
operations inter-VLAN routing, 274
CEF, 308–309 external routers/internal router processors, 276
IP MLS, 321 native VLANs, 277–279
MLS, 300–303 routed ports, 275
optical, 653 router-on-a-stick, 280–282
optical connections, 653 switch virtual interfaces, 274–275
optical infrastructures, 650 switched networks, 274
1439_CCNP_3.book Page 784 Wednesday, October 27, 2004 9:54 AM

784 optimization

troubleshooting, 286 optimization, 177–184


verification, 282–286 Path Cost, 212–213
ISL, 377 PortFast, 216–217
LLQ, 527 priority, 210–212
MLS, 315–334 Root guard, 220–221
MLS-RP, 315, 323 RSTP, 185–195
MLS-SE, 317 states, 168–171
switch, 208–210
MSFCs, 360–361
timers, 171–176, 214–216
MST, 232
topology changes, 176–177
MSTP, 226–237
UplinkFast, 217–218
multicast routing, 437–444
verification, 225–226
passwords, 44–45, 582–584, 719–721 VLAN, 213
PIM verification, 438 Supervisor Engine redundancy, 343
policing Switch A, B, and C, 324
CAR, 515 switches
DSCO map, 512 campus networks, 38–53
ports remote access, 46–48
security, 607–610 TACACS+, 620
speed, 50, 732 trunk-connected routers, 271
power supplies, 349
usernames, 585
QoS, 18–19
VLANs, 72, 100–102
RADIUS, 620
ACLs, 79–92
Root Switches, 230 links, 109–111
routers maps, 606
native VLANs, 269 security, 76–79
redundancy, 349–363 trunking, 111–114
RSPAN, 555–556, 558–564 verification, 102–103
reflector ports, 556–557 VMPS, 103–108
VLANs, 557–558 voice, 470
RSTP, 226–237 VMPS, 103–108
saving, 718 VoIP, 457
SFM, 572 VSPAN, 545–546
SPAN, 545–552 VTP, 128–131, 138–146
SSH, 596–598 adding switches, 133
STP, 207 advertisements, 134–138
BackboneFast, 218–219 modes, 131–133
BPDU guard, 219–220 WRED, 524–525
default, 207–208 options. See also optimization
enabling, 208 burst-byte, 511
load sharing, 221–225 exceed-action, 512
1439_CCNP_3.book Page 785 Wednesday, October 27, 2004 9:54 AM

paths 785

in-band management, 581–582 data, 487


IP Phones delay, 485
connectivity, 465 loss, 485
power, 466 provisioning, 487
IP Telephony, 465 video, 489
match-any, 497 voice, 488
out-of-band management, 579–581 rewriting, 298

prepend, 730 self-join (CGMP), 422

QoS, 18–19 SSH, 587–589

queue-limit, 521 Supervisor Engine redundancy, 343

remote management, 595–596 TCP, 84


ACLs, 593–594 traffic shaping, 528–533
security, 585–587 UDP, 84
VLANs, 591 PAD (packet assembler/disassembler), 631
STP, 177–184 PAgP (Port Aggregation Protocol), 242
usernames, 585 pairs, keys, 589–591
VTP configuration, 138 parameters
Designated Port (RSTP), 188
OSI (Open System Interconnection), 5, 12
OTC (operating telephone company) optical networks, Designated Ports (STP), 166–168
660 editing, 713
out-of-band management, 579–581 naming, 46
override parameter, 501 override, 501
Path Cost (STP), 159, 202, 212–213
Port ID (STP), 160
P Port Numbers (STP), 161
packet assembler/disassembler (PAD), 631 Port Priority (MST), 234
packets
Root Port (STP), 165
association, 494
Root Switch (STP), 163–164
CGMP, 422–424
passwords, 582–584, 719. See also security
congestion avoidance, 522
configuration, 44–45
LLQ, 526
line, 584
WRED, 523–526
recovery, 56–57, 721
delay, 455
strong encryption, 586
dropping, 515
Path Cost Parameter (STP), 159, 202, 212–213
dynamic transports, 666
paths
filtering, 600–602
campus networks, 9
flow, 311–315
flooding, 433
lost, 455
forwarding, 425
multicast, 442
load-sharing, 306
QoS
migration, 344
availability, 486
1439_CCNP_3.book Page 786 Wednesday, October 27, 2004 9:54 AM

786 paths

MOSPF, 432 physical coding sublayer (PCS), 670


redundancy, 356–360 physical connections, IP Phones, 465
RPF, 430 physical interfaces. See also interfaces
SPTs, 432 CBWFQ configuration, 521
patterns, traffic, 31 inter-VLAN routing, 263–265
PBX (Private Branch Exchange) WRED configuration, 524
AVVID, 387 physical layers, 391
legacy migration, 404 physical loops, 156
PCS (physical coding sublayer), 670 physical media dependent (PMD), 670
PDUs (protocol data units), 12, 294 physical security, 72, 577. See also security
components, 296–300 PIM (Protocol-Independent Multicast), 19, 394, 407, 432,
435
hardware/software requirements, 294–296
configuration, 438
operations, 300–303
neighbors, 439
peering, routers, 31
ping command, 443
per-class bandwidth allocation (CBWFQ), 520, 522
PKI (Public Key Infrastructure), 589
performance. See also optimization
platforms
bandwidth, 74–75
GLBP, 357
campus networks, 5
SLB, 362
CEF, 303
TLS support, 650
adjacency table, 311
PMD (physical media dependent), 670
comparing MLS, 303–307
PNNI (Private Network-to-Network Interface), 37
FIB, 309–310
point-to-multipoint connectivity, 653
forwarding, 311–315
point-to-multipoint TLS circuits, 658
operations, 308–309
point-to-point configuration, 638
inter-VLAN routing, 263–265
point-to-point dedicated TLS circuits, 657
Layer 3, 31, 273
Point to Point Protocol (PPP), 402
medium campus networks, 34
police aggregate policy-map configuration command, 510
small campus networks, 34 police command, 509
SPAN policers
configuration, 549–552 aggregate, 510
interaction, 548–549 defining, 512
monitoring, 545–546 individual, 509
sources, 552–554
policies
VSPAN, 545–546
access control, 575–576
per-hop behaviors (PHBs), 492
defining, 497–498
permit keyword, 84
enforcing, 515
Per-VLAN Spanning Tree (PVST), 69, 195–207
inbound-accesslayer, 506
PFC (Policy Feature Card), 273
interfaces, 507
PFC2 (Policy Feature Card 2), 308
PHBs (per-hop behaviors), 492 QoS, 495
1439_CCNP_3.book Page 787 Wednesday, October 27, 2004 9:54 AM

priority 787

service-policy command, 499 priorities, 201, 210–212


traffic shaping, 528–533 roles, 187
VMPS, 96, 103–108 routed, 275
policing RSPAN, 555–556
CAR configuration, 515 configuration, 558–564
DSCP maps, 512 reflector, 556–557
traffic, 509–516 VLANs, 557–558
Policy Feature Card (PFC), 273 security, 599, 607–610
Policy Feature Card 2 (PFC2), 308 SFP, 346
policy maps, creating, 514 source trunk, 562
POP (Post Office Protocol) SPAN
interservice connectivity, 653 configuration, 549–552
metro segmentation, 654 interaction, 548–549
Port Aggregation Protocol (PAgP), 242 monitoring, 546
Port Cost, 245 sources, 552–554
port group command, 249 speed, 50, 732
Port ID parameter, 160 STP (BackboneFast, 182
Port Numbers parameters (STP), 161 unauthorized, 637
Port Priority parameters uplink, 346
MST, 234 VMPS, 105
STP, 161 power supplies
port-based VLANs, 96 IP
port-channels, 364 Phones, 466
PortFast Telephony, 465
BPDU guards, 203 protection, 465
STP, 178, 216–217 redundancy, 348–349
ports PPP (Point to Point Protocol), 402
ACLs, 604 precedence
authorization, 637 defining, 507
autosensing, 344 IP, 464, 494
console connections, 38–39 WFQ, 518
CoS assignments, 501 preempts, HSRP standby, 373
descriptors, 731 prepend option, 730
dynamic VLANs, 108 preshared keys, 590, 725
edge, 187 Pretty Useful TTY (PUTTY), 40
Ethernet connections, 40 primary interfaces, 443. See also interfaces
identifying, 48–52 Primary Virtual Forwarder (PVF), 357
IEEE 802.1x authentication, 634–641 priority
IP Phones, 465 bridges, 158

monitoring, 545–546 Port Priority parameter (STP), 161


1439_CCNP_3.book Page 788 Wednesday, October 27, 2004 9:54 AM

788 priority

ports, 201 campus networks, 10


scheduling, 516 CGMP, 12
CBWFQ, 519–522 HSRP, 12
FIFO, 516 IGMP, 12
WFQ, 516–518 IRDP, 12
STP configuration, 210–212 MSDP, 20
switches, 213, 232 multicast routing, 432–437
voice traffic, 459 multicasting, 407
priority bandwidth command, 527 PIM, 19
priority command, 527 PPP, 402
Private Branch Exchange (PBX)
reserved link local addresses, 410
AVVID, 387
resiliency, 394
legacy migration, 404
STP, 12
Private Network-to-Network Interface (PNNI), 37
private VLANs, 71. See also VLANs VTP, 12
privileges, 586. See also security provisioning, QoS, 487
processes (STP) Proxy ARP, 350
convergence, 163–168 pruning, VTP, 132, 138–146
decision sequences, 162–163 PSTN (Public Switched Telephone Network), 22
Public Key Infrastructure (PKI), 589
processing
purging, 320
centralized call, 454
PUTTY (Pretty Useful TTY), 40
command-line, 713
PVF (Primary Virtual Forwarder), 357
distributed call, 452–453
PVST (Per-VLAN Spanning Tree), 69, 195–207
independent call, 451
production networks, 386
propagation
Auto-RP, 440
Q
QoS (quality of service)
delay, 456 acceleration, 347
protection. See also security access layer, 499–508
IP Telephony, 465
campus networks, 11, 18–19
passwords, 582–584
congestion avoidance, 522
ports
LLQ, 526
configuration, 609 WRED, 523–526
security, 599 design, 465–472
VLANs, 72
low-speed links, 533–538
protocol data units. See PDUs
models, 490
Protocol-Independent Multicast (PIM), 19, 394, 407, 432,
best-effort, 490–491
435
class-map command, 495–497
protocols
DiffServ, 492
ARP, 5
IntServ, 491
1439_CCNP_3.book Page 789 Wednesday, October 27, 2004 9:54 AM

remote access 789

MQC, 495 R
policy-map command, 497–498 RADIUS (Remote Authentication Dial-In User Service),
service-policy command, 499 615, 620
traffic marking, 492–495 random-detect command, 524, 527
NAM, 568 random-detect exponential-weighting-constant command,
policies, 495 524
random-detect precedence command, 525
requirements, 484
Rapid Spanning Tree (RST), 199
availability, 486
Rapid Spanning Tree Protocol (RSTP), 185–195
data, 487
rate-bps, 512
defining, 484
recall, command-line, 53
delay, 485
receptionphone CoS, 504
loss, 485
reconfiguration of power supplies, 349. See also
provisioning, 487
configuration
video, 489
recovery, passwords, 56–57, 721
voice, 488
reduced costs, AVVID, 390
scheduling, 516
reducedservice class, 508
CBWFQ, 519–522 redundancy
FIFO, 516 automatic load balancing, 31
WFQ, 516–518
campus networks, 9
SPAN interaction, 549
CRC, 571
TLS, 659–660
hardware, 342
traffic
AVVID, 394
marking, 509–516
DFCs, 347
shaping, 528–533
modularity, 344–346
voice, 455–464
power, 348–349
WAN, 402 routers, 349–363
quality of service. See QoS Supervisor Engines, 342–344
queries HSRP configuration, 363–378
IGMP memberships, 414 inter-VLAN routing, 262
VQP, 103, 639 large campus networks, 35–38
queue-limit command, 527 Layer 2, 29
queue-limit option, 521
SLB, 361–363
queues, 516
SRM, 360–361
CBWFQ, 519–522
reflector ports, RSPAN, 556–557
FIFO, 516
refuse message, 596
LLQ, 19
regenerators, 664
WFQ, 516–518 reliability of AVVID, 390
QVT Term, 40 reload command, 42
remote access, 46, 723. See also access
1439_CCNP_3.book Page 790 Wednesday, October 27, 2004 9:54 AM

790 Remote Authentication Dial-In User Service (RADIUS)

Remote Authentication Dial-In User Service (RADIUS), remote management, 591, 593–594
615. 620 SSH, 589
remote management. See also management Reverse Path Forwarding (RPF), 306, 430
options, 595–596 reverse-path flooding, 433
security, 585–587 rewriting
ACLs, 593–594 CoS, 501
VLANs, 591 inline rewrites, 303
remote monitoring, 555–556. See also RMON packets, 298
configuration, 558–564
RGMP (Router-Port Group Management Protocol), 410
reflector ports, 556–557 RIF (Routing Information Field), 174
VLANs, 557–558 Rivest, Shamir, and Adelman (RSA) authentication, 589
remote services, campus networks, 10 RJ-45-to-DB-25 female DTE adapters (labeled
Remote Switched Port Analyzer. See RSPAN Terminal), 39
rendezvous points (RP). See also Auto-RP RJ-45-to-DB-25 male data communications equipment
reordering images, 730 (DCE) adapters (labeled Modem), 39
replication, multicasting, 407 RJ-45-to-DB-9 female data terminal equipment (DTE)
reports, IGMP, 408, 414 adapters, 39
requests, VTP advertisements, 135 RJ-45-to-RJ-45 rollover cables, 711
requirements rlogin, 631
bandwidth, 344 RMON (Remote Monitoring), 567
role-based user administration, 568
campus network design, 9–10
roles, ports, 187
MLS, 294–296
Root Bridges, 158
QoS, 484
root guards, 205, 220
availability, 486
Root Port parameter (STP), 165
data, 487
Root Switches, 158
defining, 484
MST configuration, 230
delay, 485
Path Cost parameters, 159
loss, 485
STP
provisioning, 487
election of, 163–164
video, 489
modification, 208–210
voice, 488
Route Switch Feature Card (RSFC), 295
VLANs, 70–71
Route Switch Module (RSM), 272, 295
reserved link local addresses, 410
routed ports, 275
resiliency
router-on-a-stick
Layer 2, 28
configuration, 280–282
protocols, 394
inter-VLAN routing, 271–272
Resilient Packet Ring (RPR), 665
Router-Port Group Management Protocol (RGMP), 410
restoring configurations, 718
routers
restrictions. See also security
ACLs, 602–603
passwords, 44–45
CBWFQ configuration, 520
port security, 599
1439_CCNP_3.book Page 791 Wednesday, October 27, 2004 9:54 AM

security 791

HSRP configuration, 363–378 RSTP (Rapid Spanning Tree Protocol), 185–195


multicast groups, 442 configuration, 226–237
native VLAN configuration, 269, 277–279 verification, 225–226
peering, 31
physical security, 577
PIM configuration, 438 S
redundancy, 349–363 saving configurations, 718
scalability
RSVP, 491
backbones, 29–31
trunk-connected configurations, 271
bandwidth, 667
VLANs
campus networks, 9, 11
ACLs, 79–92
CEF, 303
latency, 75–76
routes adjacency table, 311
invalidation, 306 comparing MLS, 303–307
FIB, 309–310
inter-VLAN routing, 269
forwarding, 311–315
processors, 260
operations, 308–309
routing
inter-VLAN routing, 263–265
inter-VLAN, 259
switch blocks, 25
multicast
scheduling QoS, 516
configuration, 437–444
CBWFQ, 519–522
protocols, 432–437
FIFO, 516
RPF, 430–432
WFQ, 516–518
multicast traffic, 424–429
scope of delivery, 442
wire-speed, 15, 296
SDH (Synchronous Digital Hierarchy), 660, 664
Routing Information Field (RIF), 174
Secondary Virtual Forwarder (SVF), 357
routing protocols, 350–351
Secure Shell (SSH), 40
RP (rendezvous points), 439. See also Auto-RP
configuration, 596–598
RP Trees (RPT), 427
encryption, 587–589
rp-announce command, 439
RPF (Reverse Path Forwarding), 306, 430 SecureCRT, 40, 711
RPR (Resilient Packet Ring), 665 security, 575
RPT (RP Trees), 427 AAA, 614–634
RSA (Rivest, Shamir, and Adelman) authentication, 589 access, 598–600
RSFC (Route Switch Feature Module), 272, 295 ACLs, 600–602
RSM (Route Switch Module), 272, 295 port ACLs, 604
RSPAN (Remote Switched Port Analyzer), 545, 555–556 router ACLs, 602–603
configuration, 558–564 VLAN ACLs, 604–607
reflector ports, 556–557 access control policies, 575–576
VLANs, 557–558, 562 ACL configuration, 610–613
RST (Rapid Spanning Tree), 199 AVVID, 390, 392, 397
1439_CCNP_3.book Page 792 Wednesday, October 27, 2004 9:54 AM

792 security

encryption metro Ethernet, 655


key pairs, 589–591 QoS, 484. See also QoS
SSH, 587–589 TLS, 655–660
IEEE 802.1x port-based authentication, 634–641 session module_number command, 719
in-band management, 581–582 sessions
NAM, 568 limiting, 586
out-of-band management, 579–581 management, 600–602
passwords, 582–584, 719 multicast, 437–444
physical, 577 remote management options, 595–596
ports, 599, 607–610 RSPAN configuration, 558–564
remote management, 585–587 SPAN
ACLs, 593–594 creating, 550–552
options, 595–596 sources, 552–554
VLANs, 591 set enablepass command, 720
SSH, 596–598 set interface sc0 command, 724
VLANs, 71–79 set mls agingtime command, 319
web management interfaces, 592–593 set mls agingtime fast command, 319
segmentation set mls disable command, 318
metro, 654 set mls enable command, 318
reserved link local addresses, 410 set mls flow command, 320
set mls include command, 318
self-join packets (CGMP), 422
set password command, 720
Server Load Balancing (SLB), 361–363
set system contact command, 722
servers
set system location command, 722
ACS, 618
set system name command, 722
authentication, 392
SFM (Switch Fabric Module), 545, 564, 570–574
farms, 8
SFP (Small Formfactor Pluggable) ports, 346
RADIUS, 617
shared collaboration, AVVID, 404
single CallManager, 451 shared networks (VLANs)
Sun Sparc, 445 bandwidth, 74–75
TFTP, 581 security, 71–73
VMPS, 96, 103–108 shared trees, 427
VTP mode, 132 sharing, load, 201, 221–225
service password-encryption command, 45, 584 shortcuts, editing commands, 713
service-policy output policy1 command, 499 shortest-path trees (SPTs), 432
show access-lists command, 81
services show class-map command, 505
campus networks, 10–11 show commands, 521, 572
MAN show config command, 720
DWDM, 667 show etherchannel command, 250
SONET/SDH implementations, 664 show etherchannel load-balance command, 250
1439_CCNP_3.book Page 793 Wednesday, October 27, 2004 9:54 AM

sources (RSPAN) 793

show fabric active command, 573 show running-configuration command, 51


show fabric errors command, 574 show standby command, 367, 376
show fabric status all command, 574 show system command, 722
show fabric switching-mode all command, 573 show tacacs command, 620
show fabric utilization all command, 574 show traffic-shape command, 532
show flash command, 728 show traffic-shape statistics command, 532
show fm command, 89 show vlan access-map command, 87
show glbp command, 360 show vlan command, 102, 266
show history command, 53 show vlan filter command, 87
show interface command, 47, 52 show vmps command, 108
show interface interface-id switchport command, 145 show vtp counters command, 142, 146
show interface switchport command, 121 show vtp status command, 142
show interface trunk command, 122 shutdown command, 570
show interfaces command, 525 shutdown, port security, 599
show ip access-lists command, 82 Simple Messaging Desktop Interface (SMDI), 403
show ip cef command, 311, 333 Simple Network Management Protocol (SNMP), 593
show ip cef detail command, 310, 331 simplification, AVVID, 390
show ip cef summary command, 311, 333 simultaneous sessions, limiting, 586
show ip igmp interface command, 444 single CallManager servers, 451
show ip interface brief command, 282 Single Router Mode (SRM), 360–361
show ip interface command, 82 single-site models, IP Telephony, 450
show ip pim interface command, 438 SLB (Server Load Balancing), 361–363
show ip route command, 286 small campus networks, 34
show mls command, 328 Small Formfactor Pluggable (SFP) ports, 346
show mls entry command, 330 SMDI (Simple Messaging Desktop Interface), 403
show mls qos interface command, 506 SNA (Systems Network Architecture), 34
show mls qos maps policed-dscp command, 513 SNMP (Simple Network Management Protocol), 593
show mls rp command, 318, 326 snooping, 20, 407, 419–421
show mls rp vtp-domain command, 327 Solution Reference Network Design Guides, 391
show mls status command, 328 SONET (Synchronous Optical Network), 660
show module command, 342, 573, 719 applications, 664
show module status field, 348 AVVID, 402
show monitor session command, 560 QoS, 484
show pagp counters command, 250 TLS solutions, 650
show policy-map command, 506, 521, 528 source filtering, 418
show port capabilities command, 303, 733 source trees, 426–427
show port command, 733 source-destination-ip flow mask, 297
show port duplex command, 733 sources (RSPAN), 555–556
show port group command, 250 configuration, 558–564
show queue command, 521, 525, 528
reflector ports, 556–557
show queueing random-detect command, 525
VLANs, 557–558
show running-config command, 52, 145, 370
1439_CCNP_3.book Page 794 Wednesday, October 27, 2004 9:54 AM

794 SPAN (Switched Port Analyzer)

SPAN (Switched Port Analyzer), 545–546 static VLAN configuration, 100–102


configuration, 549–552 statistics keyword, 108
interaction, 548–549 status
port basis, 546 HSRP routers, 376
sources, 552–554 MLS, 328
Spanning Tree Protocol. See STP STM-1 (Synchronous Transport Module level 1), 663
spanning-tree bpduguard enable command, 219 Storage Networking AVVID, 400
spanning-tree loops, 29 STP (Spanning Tree Protocol)
spanning-tree vlan vlan-id root primary command, configuration, 207
208–209 BackboneFast, 218–219
sparse mode routing protocols, 434 BPDU guard, 219–220
Spatial Reuse Protocol (SRP), 665 default, 207–208
speed enabling, 208
AVVID, 390 load sharing, 221–225
ports, 50, 732 Path Cost, 212–213
speed {10 | 100 | 1000 | auto} command, 51 PortFast, 216–217
speed command, 50 priority, 210–212
SPTs (shortest-path trees), 432 Root guard, 220–221
SRM (Single Router Mode), 360–361 switches, 208–210
SRP (Spatial Reuse Protocol), 665 timers, 214–216
SSH (Secure Shell), 40 UplinkFast, 217–218
configuration, 596–598 VLAN, 213
encryption, 587–589 operations, 154–161
Standard EtherChannel, 237 optimization, 177–184
standards PortFast, 203
10 GbE, 669 processes
10 Gigabit Ethernet, 706 convergence, 163–168
Gigabit Ethernet, 702–705 decision sequences, 162–163
standardsL10BASE-T, 702 STP, 161
standby groups, HSRP, 372 PVST, 195–207
standby ip command, 370 RSPAN interaction, 557
standby preempt command, 373 RSTP, 185–195
standby routers, HSRP preempts, 373 states, 168–171
standby Supervisor Engines, 343. See also Supervisor timers, 171–176
Engines
topology changes, 176–177
standby track command, 376
verification, 225–226
states
strong encryption, 586
HSRP, 369
STS-1 (Synchronous Transport Signal level 1), 662
ports, 637
subinterfaces, inter-VLAN routing, 269
RSTP, 186
subset advertisements, 137
STP, 168–171 summary advertisements, 136
1439_CCNP_3.book Page 795 Wednesday, October 27, 2004 9:54 AM

Systems Network Architecture (SNA) 795

Sun Sparc servers, 445 Root Switch configuration, 230


Supervisor Engine II, 308 STP configuration, 208–210
Supervisor Engine IIG, 294 UplinkFast, 180
Supervisor Engine III, 294 VLAN priority, 213
Supervisor Engine IIIG, 294 switching
Supervisor Engines Layer 2, 13–14
DFCs, 347
Layer 3, 14–15
redundancy, 342–344
Layer 4, 15–16
modularity, 344–346
multilayer, 16–17
modules, 342
switchport access vlan command, 100, 266
support, CEF, 306
switchport access vlan dynamic command, 108
SVF (Secondary Virtual Forwarder), 357
switchport mode access command, 101, 116
SVIs (switched virtual interfaces)
switchport mode interface command, 115
router ACLs, 79
switchport mode trunk command, 112–113, 117, 119
inter-VLAN routing configuration, 274–275
switchport nonegotiate command, 119
Switch A configuration, 324 switchport nonegotiate interface command, 121
Switch B configuration, 324 switchport port-security mac-address command, 599
switch block, 24 switchport trunk allowed vlan command, 113
Switch C configuration, 324 switchport trunk encapsulation command, 113
Switch Fabric Module, DFCs, 347 switchport trunk native vlan command, 113
Switch Fabric Module (SFM), 545, 564, 570–574 switchport trunk native vlan vlan-id interface command,
switched networks, 274 267
Switched Port Analyzer. See SPAN switchport trunk pruning command, 144
switched virtual interfaces (SVIs) switchport tuning command, 205
router ACLs, 79 switchport voice vlan dot1p command, 471
inter-VLAN routing configuration, 274–275 symmetric keys (preshared keys), 590
switches synchronization, global, 522
access, 579 Synchronous Digital Hierarchy (SDH), 660, 664
authentication, 635 synchronous multiplexing, 663
block connections, 38 Synchronous Optical Network (SONET), 660
campus network configuration, 38–53 applications, 664
chassis-based, 260 AVVID, 402
console port connections, 38–39 QoS, 484
default behavior, 143 TLS solutions, 650
Ethernet port connections, 40 Synchronous Transport Module level 1 (STM-1), 663
MST, 200 Synchronous Transport Signal level 1 (STS-1), 662
syntax, VLAN maps, 85
naming, 46
system names, CatOS, 722
physical security, 577
Systems Network Architecture (SNA), 34
priority, 232
remote access configuration, 46–48
1439_CCNP_3.book Page 796 Wednesday, October 27, 2004 9:54 AM

796 tables

T thresholds, TTL, 428


tables time, aging (MLS), 318
adjacency, 306, 311 timeouts, idle, 57
CAM, 297 timers
CEF, 306 HSRP hello, 373
CEF FIB, 309–310 MSTP, 235
FIB, 306 RSTP, 190–194
NetFLow, 306 STP, 171–174, 214–216
TACACS+ (Terminal Access Controller Access Control Time-To-Live (TTL), 15, 428
System), 615, 620 TLS (transparent LAN services), 649
tag control information (TCI), 126 architecture, 655–660
tag protocol identifier (TPID), 126 Ethernet solutions, 649–655
tagging VLANs, 94, 122–123 QoS, 659–660
IEEE 802.10 protocol, 126–127 solutions, 650
IEEE 802.1Q protocol, 125–126 token buckets, policing, 511
ISL, 123–125 tools, NAM, 566–570
LANE, 127–128 topologies
tail-drop, 522 802.1x port-based authentication, 638
TC (Topology Change) bits, 175 loop-free logical
TCA (Topology Change Acknowledgement) bits, 175 convergence (STP), 163–168
TCI (tag control information), 126 STP decision sequences, 162–163
TCN (Topology Change Notification), 175 STP, 176–177
TCP (Transmission Control Protocol), 84
Topology Change (TC) bits, 175
TCP/IP (Transmission Control Protocol/Internet
Topology Change Acknowledgment (TCA) bits, 175
Protocol), 522
Topology Change Notification (TCN), 175
TDM (Time-Division Multiplexing), 387
ToS (Type of Service) fields, 492
technology characteristics, 11–12
TPID (tag protocol identifier), 126
telephony (IP), 444
tracking interfaces, 375
AVVID, 395
traditional campus networks, 4–9
design, 450–454
traffic
high availability, 467
broadcast, 73
infrastructure, 467
classes
power/protection options, 465
VLANs, 470 CBWFQ, 519–522
Telnet, 593, 711 defining, 495–497
Tera Term, 40, 711 classification, 461
Terminal Access Controller Access Control System Plus default switch behavior, 143
(TACACS+), 615, 620 flows, 495, 516–518
terminal emulation, 711 inter-VLAN routing, 259
terminal history size command, 54 marking, 492–495
TFTP (Trivial FTP) servers, 581 monitoring, 545–546
1439_CCNP_3.book Page 797 Wednesday, October 27, 2004 9:54 AM

troubleshooting 797

multicast Transmission Control Protocol (TCP), 84


configuration, 437–444 Transmission Control Protocol/Internet Protocol
management, 428–429 (TCP/IP), 522
protocols, 432–437 transparent LAN services. See TLS
routing, 424–427 transparent mode, 130, 133
RPF, 430–432 transports
multicasting, 407 dynamic packets, 666
patterns, 8, 31 intermetro LAN, 652
policies, 497–498 trees
QoS, 484 CBT, 435

availability, 486 distribution


classification at access layer, 499–508 CGMP, 425
data, 487 RPF, 430–432
defining, 484 FIB, 309
delay, 485 multicast delivery, 432–437
loss, 485 shared, 427
marking, 509–516 source, 426–427
policing, 509–516 SPTs, 432
provisioning, 487 Triple-DES (3DES), 589
shaping, 528–533 Trivial FTP (TFTP) servers, 581
video, 489 troubleshooting
voice, 488 BackboneFast, 182
security, 598–600 bandwidth, 74–75
ACLs, 600–602 BPDU guards, 203
port ACLs, 604 first-hop router failures, 350
router ACLs, 602–603
GLBP, 360
VLAN ACLs, 604–607
help command, 715–716, 718
SPAN
HSRP, 378
configuration, 549–552
inter-VLAN routing configuration, 286
interaction, 548–549
IOS, 54–55
monitoring, 546
sources, 552–554 IRDP, 352
voice prioritization, 459 MLS, 294
traffic-shape adaptive command, 531 components, 296–300
traffic-shape fecn-adapt command, 531 hardware/software requirements, 294–296
traffic-shape rate command, 531 operations, 300–303
trails, echo, 457 NAM, 568–569
transitions power supplies, 348–349
PortFast, 203 root guards, 205
RSTP, 191 routers, 31
STP states, 170 SLB, 362
1439_CCNP_3.book Page 798 Wednesday, October 27, 2004 9:54 AM

798 troubleshooting

SSH, 596–598 unauthorized access


Supervisor Engines, 343 passwords, 44–45
traffic shaping, 528–533 unauthorized ports, 637
UplinkFast, 180 unused fiber-optic bandwidth, 668
voice, 455–464 uOne Messaging System components, 445
VRRP, 356 updates, STP, 177
uplink ports, Supervisor Engines, 346
truncated mode, SFM, 571
UplinkFast, STP configuration, 217–218
trunk command, 113
UplinkFast (STP), 180
trunk mode, DTP, 117
UPS (uninterruptible power supply), 465
trunk-connected router configurations, 271
user accounts
trunked ports, SPAN interaction, 548
binding, 587
trunking, 12
creating, 586
Administrative Trunking Encapsulation, 121
sessions, 586
interfaces, 269
User Datagram Protocol. See UDP
inter-VLAN routing, 260
user VLANs, 266
links, 377
username Helpdesk privilege 1 command, 586
Negotiation of Trunking, 121 username name access-class access-list command, 587
RSPAN interaction, 557 username name nopassword command, 586
VLANs, 111–120 username name privilege level command, 586
VTP, 128–131 username name secret password command, 586
adding switches, 133 username name user-maxlinks number command, 586
advertisements, 134–138 usernames, 585
configuration, 138–146 users
modes, 131–133 access. See access
trust, 499 VLANs, 70–71
boundaries, 459
CoS configuration, 500
TTL (Time-To-Live), 15, 428 V
tunneling, 651–652 vacant message, 596
Type of Service (ToS) fields, 492 values
types DSCPs, 502
of EtherChannels, 237 ToS, 464
of inter-VLAN routing, 265–269 variables, campus networks, 23–33
of services, 491 variation, delay (QoS), 485
VC (virtual container) capacity, 663
verification
ACLs, 87, 610–613
U
UDP (User Datagram Protocol) CEF, 331
HSRP messages, 368 DTP, 120–121
packets, 84 EtherChannel configuration, 249
1439_CCNP_3.book Page 799 Wednesday, October 27, 2004 9:54 AM

VLANs (virtual LANs) 799

GTS configuration, 532 vlan filter command, 84


HSRP routers, 376 VLAN identifier (VID), 126
inter-VLAN routing configuration, 282–286 VLAN Management Policy Server (VMPS), 96, 103–108
MLS, 326 VLAN Query Protocol (VQP), 103, 639
MSTP, 225–226 VLAN Trunking Protocol. See VTP
VLAN-based Switched Port Analyzer. See VSPAN
PIM configuration, 438
VLANs (virtual LANs), 68–70, 79–92, 114–121, 265
port security, 607–610
ACLs, 604–607
RSTP, 225–226
auxiliary connections, 471
SSH, 596–598
bandwidth, 74–75
STP, 225–226
broadcasts, 73
VLAN configuration, 102–103
configuration, 72, 100–103
VTP
encapsulation, 123
configuration, 142
identification, 122–123
pruning, 145
IEEE 802.10 protocol, 126–127
WRED configuration, 525
IEEE 802.1Q protocol, 125–126
versions
ISL, 123–125
IGMP modification, 443
LANE, 127–128
VTP configuration, 139
IGMP snooping, 420
VF (Virtual Forwarder), 356
inter-VLAN routing, 259
VID (VLAN identifier), 126
IP Telephony implementation, 470
video
ISL, 377
AVVID, 386–401
legacy networks, 70–71
implementation, 401–405
links, 109–111
QoS, 489
management interfaces, 724
videoconferencing, 396
maps, 79–92
AVVID, 404
maximum aging time, 215
bandwidth requirements, 490
mirroring, 562
voice, 458
multiple HSRP groups, 364
viewing MLS status, 328
NAM, 566–570
violations, port security, 599. See also security
native, 113
virtual container (VC) capacity, 663
Virtual Forwarder (VF), 356 ports, 210–212
virtual LANs. See VLANs remote management, 591
virtual MAC addresses, 371 routers
virtual private networks (VPNs), 392, 397 ACLs, 79–92
Virtual Router Redundancy Protocol (VRRP), 355–356 latency, 75–76
virtual routers, MAC addresses, 366 RSPAN, 557–558, 562
virtual servers, SLB, 361–363 security, 71–79
vlan database command, 138 SPAN, 548, 552–554
1439_CCNP_3.book Page 800 Wednesday, October 27, 2004 9:54 AM

800 VLANs (virtual LANs)

STP vtp domain command, 140


configuration, 213 vtp mode command, 141
enabling, 208 vtp password command, 133, 140
trunking, 111–114 vtp pruning command, 144
tunneling, 651–652 vty connections, restrictions, 594
types, 92 VVID (Voice VLAN ID), 469
boundaries, 93
dynamic, 98–99
end-to-end, 94–95 W
local, 95–96 wall power, IP Phones, 467
memberships, 96–98 WANs (wide area networks)
VMPS, 96, 103–108 AVVID, 402
voice configuration, 470 multisite IP
VMPS (VLAN Management Policy Server), 96, 103–108 centralized call processing, 454
voice distributed call processing, 452–453
AVVID, 386–401 WDM (wavelength division multiplexing), 402
design, 465–472 Web access, NAM, 568
Web management interfaces, security, 592–593
implementation, 401–405
WFQ (weighted fair queuing), 516–518
IVR, 388
wide area networks. See WANs
NAM, 568
wire-speed Gigabit connectivity, 653
QoS, 488
wire-speed routing, 15, 296
troubleshooting, 455–464 WLANs (wireless LANs), 396
voice VLAN configuration, 470 workgroups, 68
Voice VLAN ID (VVID), 469 workstations
Voice, Video, and Integrated Data. See AVVID connections, 38
VoIP (voice over IP), 19, 457 redundant router access, 350–351
VPNs (virtual private networks), 392, 397
WRED (Weighted Random Early Detection), 19, 463, 491,
VQP (VLAN Query Protocol), 103, 639 523
VRRP (Virtual Router Redundancy Protocol), 355–356 WRR (Weighted Round Robin), 463
VSPAN (VLAN-based Switched Port Analyzer), 545
VTP (VLAN Trunking Protocol), 12, 128–131
adding switches, 133
advertisements, 134–138
configuration, 138–146
domains, 102
modes, 131–133
pruning, 132, 138–146
RSPAN interaction, 557
1439_CCNP_3.book Page 801 Wednesday, October 27, 2004 9:54 AM
1439_CCNP_3.book Page 802 Wednesday, October 27, 2004 9:54 AM
1439_CCNP_3.book Page 803 Wednesday, October 27, 2004 9:54 AM
1439_CCNP_3.book Page 804 Wednesday, October 27, 2004 9:54 AM

You might also like