0% found this document useful (0 votes)
121 views4 pages

Filter

This document provides specifications for Siloair Dust Filters series VS10-28. It includes: 1) Dimensions and weights for various filter models with different filtration areas and fan configurations. 2) Details on components like access doors, lifting brackets, and compressed air inlets. 3) Front and side elevation diagrams of a sample filter model with an integral fan and optional weather cowl.

Uploaded by

Reza Saee
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
121 views4 pages

Filter

This document provides specifications for Siloair Dust Filters series VS10-28. It includes: 1) Dimensions and weights for various filter models with different filtration areas and fan configurations. 2) Details on components like access doors, lifting brackets, and compressed air inlets. 3) Front and side elevation diagrams of a sample filter model with an integral fan and optional weather cowl.

Uploaded by

Reza Saee
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Data Sheet

Siloair Dust Filters


Series VS10-28

500 765 500 500 A 500


required for required for required for required for
maintenance maintenance maintenance maintenance
110 b

Lift-off
access door 75

Lifting Compressed
brackets (4) air inlet
(1/2" B.S.P. Parallel)
1550
2050
required for Acoustic
maintenance diffuser
(optional)
870

Centre-line
of aperture
Seating level

An optional 50mm high Controller


Aperture upstand can be supplied to Aperture
aid installation
FRONT ELEVATION SIDE ELEVATION

Siloair filter with integral fan


Model VS28 KS5 illustrated

SPECIFICATIONS
DIMENSIONS Approx.
Filter Filtration No. of in millimetres Fan Fan net
type area cartridges type motor
A b weight
1200 KS1 0.75 kW 221 kg*
VS10 10m2 4 445
1215 KS3 1.50 kW 244 kg*
1200 KS1 0.75 kW 224 kg*
VS14 14m2 4 445
1215 KS3 1.50 kW 247 kg*
1480 KS1 0.75 kW 252 kg*
VS15 15m2 6 1495 585 KS3 1.50 kW 275 kg*
1785 KS3 1.50 kW 312 kg*
VS20 20m2 8 1810 730 KS5 2.20 kW 317 kg*

VS21 21m2 6 1495 585 KS3 1.50 kW 279 kg*


1520 KS5 2.20 kW 284 kg*

VS28 28m2 8 1810 730 KS5 2.20 kW 322 kg*


1840 KS7 3.00 kW 334 kg*

*Indicates heaviest configuration

Publication 1575G (GB) • 1207


Donaldson reserve the right to alter design without notice. Freedom from patent restrictions must not be assumed.
Data Sheet
Siloair Dust Filters – Series VS10-28

A
SPECIFICATIONS
DIMENSIONS Approx.
Filter in millimetres net
type
A weight
VS10W
960 176 kg
VS14W

VS15W 1240 208 kg


VS21W
Weather cowl
VS20W
VS28W 1530 246 kg

For all other dimensions refer to


specification table on page 1

SIDE ELEVATION

Siloair filter with weather cowl


Model VS28W illustrated

40 40 47.5 47.5
180 175 180 200 200 200 200
85 35 85 35
FRONT OF FILTER

FRONT OF FILTER

205 205

225 765 835 225 765 835

205 205

85 85
575 35 855 35
35 35
645 925
VS10 and 14 VS15 and 21
85
85 205 200 205 200 205
35
FRONT OF FILTER

205

225 765 835

205

85
1145 35
35
1215

VS20 and 28
Aperture and mounting flange details
All holes 12mm diameter for M10 bolts

ELECTRICAL REQUIREMENTS DESIGN LIMITS (standard equipment)


VS10, 14, 15 and 21 filters: 2-way controller
Temperature range: −10° to +60°C
VS20 and 28 filters: 3-way controller
Pressure range: −500mm W.G. to +380mm W.G.
Voltage input: AC version: 105-120V, 200-240V (±10%)
DC version: 24V Dimension tolerances: ±5mm on main dimensions
Fan motor (if fitted): To suit local voltage ±2mm on detail dimensions

2
Data Sheet
Siloair Dust Filters – Series VS10-28

Weather cowl

Spigot
265 x 210 o/s
1140

Centre-line
of filter

FRONT ELEVATION SIDE ELEVATION

Optional weather cowl duct connection spigot


NOTE: Spigot projects 100mm

Fan box

Spigot
265 x 210 o/s
740
Centre-line
of aperture

410 VS10/14
180 550 VS15/21
695 VS20/28

Optional fan box duct connection spigot

Acoustic
diffuser

Spigot
265 x 210 o/s
(may be fitted either
side or front)
520
Centre-line Centre-line
of filter of aperture

475 VS10/14
615 VS15/21
760 VS20/28
660 VS10/14
800 VS15/21
945 VS20/28

Optional acoustic diffuser duct connection spigot


NOTE: Spigot projects 100mm

3
300

FAN SELECTION
FAN STATIC PRESSURE (mm W.G.)

250
To select the most suitable fan for a given application:
200
1 Determine the air volume, in m3/h, needed to give effective
venting and dust control.
150 KS5 2 Estimate the pressure or suction (mm W.G.) in the housing
on which the dust filter is positioned.
KS3 KS7
100
3 Assess the operational pressure drop (mm W.G.) across the
clean side and dirty side of the filtering element – usually
50
KS1
between 50 to 125mm W.G.

4 The sum of 2 and 3 gives the pressure (mm W.G.) required


for fan selection purposes.
0 1000 2000 3000 4000 5000
AIR VOLUME (m3/h) 5 Consult graph for fan performances available.

Fan performance curves

NOISE LEVELS
Machinery noise levels are an important consideration in the design and selection of new equipment.
Several EC Directives and National Laws/Regulations adopting these directives make reference to airborne noise emissions.
Actions that employers are required to comply with if employees are subjected to a daily personal
noise exposure Lep,d of 85 dB(A) or more are also specified.
All Siloair filters, when fitted with acoustic diffuser, are below this action limit.

WEIGHTED SOUND PRESSURE LEVELS


All readings were taken in normal industrial areas, i.e. semi-reverberant surroundings, with local equipment silent,
at 1.0 metre radius from the equipment housing and 1.6 metres above base level,
using a precision sound level meter and octave filter.

KS1 KS3 KS5 KS7


With accoustic 74 dB(A) 74 dB(A) 76 dB(A) 79 dB(A)
Without accoustic 83 dB(A) 81 dB(A) 85 dB(A) 87 dB(A)
Noise levels of installed equipment may vary due to site conditions

COMPRESSED AIR REQUIREMENTS


Filter Working compressed Atmospheric air volume – F.A.D. b
Pulse duration
type air pressure a at 12 sec. intervals c
VS10 4.1 bar 60 psig 6.4 m3/h 3.7 cfm 100 millisec.
VS14 4.8 bar 70 psig 7.2 m3/h 4.2 cfm 100 millisec.
VS15 4.8 bar 70 psig 8.1 m /h
3
4.8 cfm 100 millisec.
VS20 4.8 bar 70 psig 8.1 m3/h 4.8 cfm 100 millisec.
VS21 5.2 bar 75 psig 8.9 m3/h 5.2 cfm 100 millisec.
VS28 5.2 bar 75 psig 8.9 m /h
3
5.2 cfm 100 millisec.
a
Normal operating pressure. Recommended atmospheric air volume of clean, dry compressed air.
b

c
Recommended initial settings; these may be varied with experience.
For connection details please refer to Donaldson.

Humberstone Lane Research Park Zone 1


Thurmaston Interleuvenlaan 1
Leicester LE4 8HP B-3001 Leuven (Heverlee)
England Belgium
www.donaldson.com Tel +44 (0)116 269 6161 Tel +32 (0)16 383 970
Fax +44 (0)116 269 3028 Fax +32 (0)16 383 938
Email: [email protected] Email: [email protected]