The document contains logs from various network devices with information about different types of issues:
- Interface status changes, fiber/module issues, VLAN flapping due to access topology loops, temperature alarms and power supply failures.
- The logs would need to be reviewed and the relevant teams engaged to address issues like port channel misconfigurations, ASIC card errors and prolonged interface outages.
- Recurring errors may require engaging the packet team to further investigate and resolve network problems.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
50 views
Line Protocol: Cacti Logs Types of Logs
The document contains logs from various network devices with information about different types of issues:
- Interface status changes, fiber/module issues, VLAN flapping due to access topology loops, temperature alarms and power supply failures.
- The logs would need to be reviewed and the relevant teams engaged to address issues like port channel misconfigurations, ASIC card errors and prolonged interface outages.
- Recurring errors may require engaging the packet team to further investigate and resolve network problems.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 6
Cacti Logs
Types of Logs
Mar 1 10:05:01 Lah-Khalid-Plaza-H11-P76R2[58.27.191.216]
040402: Mar 1 10:04:36.067 GMT: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet3/1, changed state to down
Mar 1 14:57:31 Kar-12816-p1[58.27.191.31] 030827: Mar 1
14:57:04.334 GMT: %OSPF-5-ADJCHG: Process 1, Nbr Isb-12816- p1[58.27.191.57] on GigabitEthernet5/0/4 from FULL to DOWN, Neighbor Down: BFD node down
Feb 28 08:54:42 Sheikhupura-ME3400B[58.27.180.54] :
%SW_MATM-4-MACFLAP_NOTIF: Host 001e.13e5.7e40 in vlan 2134 is flapping between port Gi0/16 and port Gi0/3
Feb 28 20:21:34 Lah-hdc-7609-intgw02[58.27.190.190] 133089: Feb
28 20:21:06.676 GMT: %OIR-SP-3-PWRCYCLE: Card in module 5, is being power-cycled (Module reset)
Feb 26 07:18:31 Lah-Near-UET-H09-P76R2[58.27.191.215] 022457:
Feb 26 07:18:05.326 GMT: %C6KENV-SP-4-MINORTEMPALARM: module 1 inlet temperature crossed threshold #1(=45C). It has exceeded normal operating temperature range.
Feb 28 02:24:20 Kar-GGC-3850-SW1[58.27.182.70] GMT: %LINK-3-
UPDOWN: Interface TenGigabitEthernet1/0/1, changed state to down
Feb 27 17:00:42 Guj-me3750-01[172.22.32.60] 006275: Feb 27
17:00:16.392 GMT: %POWER_SUPPLIES-5-PWR_OK: Power supply B is functioning
Feb 27 15:31:56 Kar-7609-intgw2[58.27.190.242] 100996: Feb 27
15:31:30.895: %C7600_PWR-SP-2-PSFAIL: power supply 1 output failed.
Feb 27 15:31:56 Kar-7609-intgw2[58.27.190.242] 100997: Feb 27
15:31:30.895: %C7600_PWR-SP-4-PSREDUNDANTONESUPPLY: in power-redundancy mode, system is operating on one power supply.
Feb 27 12:19:11 Skt-7609-PE1[58.27.191.9] 029507: Feb 27
12:19:28.193 GMT: %PM-SP-4-ERR_DISABLE: pagp-flap error detected on Gi9/8, putting Gi9/8 in err-disable state
Feb 27 12:19:12 Skt-7609-PE1[58.27.191.9] 029508: Feb 27
12:19:28.312 GMT: %PM-SP-STDBY-4-ERR_DISABLE: pagp-flap error detected on Gi9/8, putting Gi9/8 in err-disable state Feb 26 13:40:35 Lah-hdc-6513-dc2[58.27.190.192] 163410: Feb 26 13:40:09.628 GMT: %SIBYTE-DFC3-3-CORRECTABLE_ECC_ERR: A correctable ECC error has occurred, A_BUS_L2_ERRORS: 0x0, A_BUS_MEMIO_ERRORS: 0xFF, A_SCD_BUS_ERR_STATUS: 0xC0DC3000 Cacti Logs Description
Fiber/Sfp issue/module issue
Fiber/module issue
Vlan flapping due to access topology issue (Loop in access end topology)
Physical Hardware failure Issue
Temperature issue
Not in packet control, but port shouldn’t be down for long.
Power supply / power issue
Power supply issue
Port channel configuration issue
ASIC card errors Action Taken
Engage relevant team. OFC/Packet
Engage relevant team. OFC/Packet
Not relevant
Engage packet (Critical)
Engage Infra team asap
Engage packet if port is down from 3 4 hours
Engage packet/infra accordingly.
Engage packet (Critical)
If core then engage packet accordingly.