0% found this document useful (0 votes)
211 views3 pages

Clean Room Test

Clean room Fundamentals

Uploaded by

Ahmed Mostafa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
211 views3 pages

Clean Room Test

Clean room Fundamentals

Uploaded by

Ahmed Mostafa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 3
ar7r019 Testing & Validation - OMS TESTING & VALIDATION Cleanrooms play critical roles in maintaining contamination free production environments for critical processes. A well-executed cleanroom testing and certification program is essential. It is required for proper cleanroom maintenance, operation, and regulatory compliance. In accordance with ISO 14644, IEST RP C006 and NEBB certified cleanroom performance testing guidelines. Century Mechanical Systems Factory (CMS) provides comprehensive cleanroom testing and certification PRIMARY TESTS MODEL: AIR VELOCITY TEST / AIR FLOW TEST/ AIR CHANGE RATE CALCULATION PRIMARY TESTS: + To evaluate airflow velocity and supply air volume in unidirectional and non-unidirectional clean room/zone & + To calculate the number of air changes per hour. HEPA LEAK TEST PRIMARY TESTS: + Covers the installed filters system leak testing by Aerosol/Photometer challenge Method and Aerosol total penetration method in occupancy state "As Built & At Rest” AIRBORNE PARTICLE COUNT TEST PRIMARY TESTS: 11min to Spreed cemsglobal.comair-siterstesting-vadation! 1 ar7r019 Testing & Validation - OMS + Covers the Air Borne Particle Count test in clean room/zone at Occupancy state “as-buil rest or in-operation”, ROOM DIFFERENTIAL PRESSURE TEST PRIMARY TESTS: + To estimate the pressure difference across clean rooms SECONDARY TESTS MODEL: AIR VELOCITY TEST / AIR FLOW TEST/ AIR CHANGE RATE CALCULATION SECONDARY TESTS: + To demonstrate the actual airflow pattern throughout the work zone of the clean room + Covers the Air flow pattern testing of clean room or space at occupancy state of "As Built “At Rest” & “In Operation” TEMPERATURE & HUMIDITY MEASUREMENT TEST SECONDARY TESTS: To demonstrate the capability of the installations air handling system to maintain the temperature and humidity level within control limits and over the time period between customer & suppliers. Covers the General temperature & humidity test of an installation in the “As Built” condition & Comprehensive temperature & humidity test for clean room for “At Rest” & “In Operation” state SOUND LEVEL TEST SECONDARY TESTS: + To measure & validate the permissible levels of sound in clean rooms LIGHT INTENSITY TEST SECONDARY TESTS: + To measure & validate the intensity of light in clean rooms RECOVERY TEST 11min to Spreed cemsglobal.comair-siterstesting-vadation! 20 ar7r019 Testing & Validation - OMS SECONDARY TESTS: * To determine the amount of time necessary for non-unidirectional clean rooms or clean spaces and its systems to reach a specified steady state of cleanliness level after a system shutdown or power failure following start up. + Covers the recovery testing for non-unidirectional clean rooms INDOOR AIRQUALITY TEST SECONDARY TESTS: + Testing for maximum indoor pollutant concentrations for acceptance of cleanroom facility MICROBIAL SWAB TEST SECONDARY TESTS: + Tests for analysing & counting the total number of aerobic bacteria, yeasts and molds present in any cleanroom surface. CMS Printing Press CMS Logistics Excelair Products © 2019 CMS Group of Companies - All ights reserved. 11min to Spreed cemsglobal.comair-siterstesting-vadation! aa

You might also like