0% found this document useful (0 votes)
318 views2 pages

TF TFF TFFN

This document provides information on 600V flexible copper conductor types TF, TFF, and TFFN. TF and TFF conductors have PVC insulation and are designed to operate at 60C. TFFN conductors have PVC insulation and a nylon jacket, and are designed to operate at 90C dry and 75C wet. These conductors can be used for internal wiring of lamps or equipment where protected from bending or damage. They also connect branch circuit lamps according to NEC standards but cannot be used as branch circuit conductors. The document lists specifications, markings, installation guidelines, and technical details.

Uploaded by

danielliram993
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
318 views2 pages

TF TFF TFFN

This document provides information on 600V flexible copper conductor types TF, TFF, and TFFN. TF and TFF conductors have PVC insulation and are designed to operate at 60C. TFFN conductors have PVC insulation and a nylon jacket, and are designed to operate at 90C dry and 75C wet. These conductors can be used for internal wiring of lamps or equipment where protected from bending or damage. They also connect branch circuit lamps according to NEC standards but cannot be used as branch circuit conductors. The document lists specifications, markings, installation guidelines, and technical details.

Uploaded by

danielliram993
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

TF / TFF / TFFN

600V Flexible Copper Conductor. (Thermoplastic


Insulated Flexible and Fixture Nylon Jacket Conductor)

twist while operation. In a similar application,


PVC Insulation Flexible Soft connecting lamps from the branch circuit
Copper Conductor
conductors as indicated at Art. 402 of NEC
2002. However, TF/TFF/TFFN shall not be
Detail Description used as branch circuit conductors.
or Construction These conductors are also used for wiring
Type TF/TFF/TFFN is a flexible insulated of control systems.
single conductor composed by solid and
bunch-stranded bare annealed copper wires;
Standards / Testing
TF/TFF conductors has a thermoplastic
insulation of PVC (Polyvinyl Chloride) and Specifications
the TFFN has PVC isolation and protected • TF/TFF conductors have been designed
with a Nylon sheath. Designed to operate according to ASTM B3, B174, UL-62 and
at not more than 600VAC, TF/TFF/TFFN UL-1581 specifications.
are manufactured in sizes 18AWG and
16AWG, available colors are black, white, Marking
red, blue, green, yellow, orange, gray, PHELPS DODGE TFFN (GAUGE) AWG
and brown. ((GAUGE) mm”) 600V OR GAS & OIL RES.
II OR AWM (UL) E-101779 VW-1.
Application
TF/TFF conductors have been designed Installation
to operate at 60ºC in dry or wet conditions. TF/TFF/TFFN conductors have been
In the other hand, TFFN conductors were manufactured to operate in wiring of lamps or
designed to operate at 90ºC in dry conditions similar devices where be protected to be bent
and 75ºC in wet conditions. o damaged. Besides, these conductors might
These conductors could be used at internal be use connecting to branch circuit lamps or
wiring of lamps or similar equipment, where other apparatus of low energy consumption
they be protected with no risk to be bend or according to Art. 402 of NEC 2002.

1 www.pdic.com PDIC01202 | 11.18.05


TF / TFF / TFFN
600V Flexible Copper Conductor. (Thermoplastic
Insulated Flexible and Fixture Nylon Jacket Conductor)

TECHNICAL INFORMATION
Max.C.D. Max.
Cross No. of Nominal Approximate Electrical Approx. Current Standard
Size Section Strands / Isolation External Resistance Total Capacity Packaging
Area Gauge Thickness Diameter @30°C Weight @ 30°C

AWG mm² No. / AWG in mm in mm Ω / km kg / km A m

TF 18 0.82 1 0.030 0.76 0.100 2.55 22.3 13 6 CB 100


TF 16 1.31 1 0.030 0.76 0.111 2.81 13.9 18 8 CB 100
TFF 18 0.82 10/28 0.030 0.76 0.107 2.72 22.7 14 6 CB 100
TFF 16 1.31 16/28 0.030 0.76 0.119 3.02 14.2 20 8 CB 100
TFFN 18 0.82 10/28 0.015 0.38 0.085 2.16 22.7 11 6 CB 100
TFFN 16 1.31 16/28 0.015 0.38 0.097 2.46 14.2 16 8 CB 100

Packaging:
WR: Wooden Reel, CB: Carton Box, C: Coils

2 www.pdic.com PDIC01202 | 11.18.05