Standard Assembly of IF Connector (China Manufacture)
Standard Assembly of IF Connector (China Manufacture)
Step-1 Step-2
8D-FB connector Pin Use the short conductor insert into the
connector Pin,and check it whether very
loose.
Step-3 Step-4
If the connector Pin very loose,then The Pin had already been clamped
Use the plier to clamp the Pin. For tight.
clamp
Step-5 Step-6
Lock nut,flat ring,and rubber gasket Remove outer insulator about 30mm.
Insert into IF cable.
Step-7 Step-8
Shave off outer inaulator about 10mm Shaves to taper on the side edge.
to taper.
Step-9 Step-10
Insert clamp ring into outer If outer is 0.5mm or more,cut out extra
strongly.outer end is stuck out about rubbish by knife when clamp ring
0.5mm from edge of clamp ring. strongly inserted.
Step-11 Step-12
Fold back braided ahield and trim cut Cut aluminum shield in about half and
divided
Step-13
Fold back aluminum shield
Step-17(H type)
Cut center conductor in 17mm,Taper
the end of center conductor using file
Step-18 (H type) Step-19 (H type)
Insert metal bush/insulator to center Set metal bush/insulator in the
conductor. connector correctly.
Step-20 (H type)
Insert cable straight in the connector
so that the center conductor may
enter a center pin.
Step-21 (H type)
Tightening turns by lock nut. Turn only lock nut.
Don't turn connector side.
Space between lock nut and connector, 1.5mm is limits.
Don’t tighten lock nut strongly.
If the locknut is tightened very strongly, Outer shield will be torn off in the connector.
Completed
For L type connectors
Step-19 (L type)
Tighten lock nut.
Don't turn connector side. Turn only lock nut.
Space between lock nut and connector, 1.5mm is limits.
Don’t tighten lock nut strongly.
If lock nut is tightened very strongly, Outer shield will be torn off in the connector.
completed
Note in Installation: