This document provides assembly instructions for standard IF connectors used in China. It outlines 19 steps for assembling H-type connectors and 17 steps for L-type connectors. Key steps include inserting the pin into the connector, clamping loose pins, removing insulation, tapering edges, folding back shields, and cutting the center conductor. It stresses that the connector should not be turned during assembly and tightening, and the locknut should not be overtightened to avoid tearing the outer shield.

Uploaded by

Amerullah Niazi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
110 views

Standard Assembly of IF Connector (China Manufacture)

This document provides assembly instructions for standard IF connectors used in China. It outlines 19 steps for assembling H-type connectors and 17 steps for L-type connectors. Key steps include inserting the pin into the connector, clamping loose pins, removing insulation, tapering edges, folding back shields, and cutting the center conductor. It stresses that the connector should not be turned during assembly and tightening, and the locknut should not be overtightened to avoid tearing the outer shield.

Uploaded by

Amerullah Niazi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

Standard assembly of IF connector(China manufacture)

This standard is suitable for current Chinese suppliers product. Any


modification in design and construction will be noticed and lead to
different assembly.

Step-1 Step-2
8D-FB connector Pin Use the short conductor insert into the
connector Pin,and check it whether very
loose.

Step-3 Step-4
If the connector Pin very loose,then The Pin had already been clamped
Use the plier to clamp the Pin. For tight.

clamp
Step-5 Step-6
Lock nut,flat ring,and rubber gasket Remove outer insulator about 30mm.
Insert into IF cable.

Step-7 Step-8
Shave off outer inaulator about 10mm Shaves to taper on the side edge.
to taper.
Step-9 Step-10
Insert clamp ring into outer If outer is 0.5mm or more,cut out extra
strongly.outer end is stuck out about rubbish by knife when clamp ring
0.5mm from edge of clamp ring. strongly inserted.

Step-11 Step-12
Fold back braided ahield and trim cut Cut aluminum shield in about half and
divided
Step-13
Fold back aluminum shield

For H type connectors

Step-14(H type) Step-15(H type)


Overlaps aluminum with braided shield Cut outinner insulator from the root
and trim cut
Step-16(H type)
Remove inner insulator

Step-17(H type)
Cut center conductor in 17mm,Taper
the end of center conductor using file
Step-18 (H type) Step-19 (H type)
Insert metal bush/insulator to center Set metal bush/insulator in the
conductor. connector correctly.

Step-20 (H type)
Insert cable straight in the connector
so that the center conductor may
enter a center pin.
Step-21 (H type)
Tightening turns by lock nut. Turn only lock nut.
Don't turn connector side.
Space between lock nut and connector, 1.5mm is limits.
Don’t tighten lock nut strongly.
If the locknut is tightened very strongly, Outer shield will be torn off in the connector.

Completed
For L type connectors

Step-14 (L type) Step-15 (L type)


Insert metal bush to center conductor. Insert metal bush to close the shield.

Step-16 (L type) Step-17(L type)


Cut out inner insulator from the root Cut center conductor in 12mm,Taper the end
of center conductor using file
Step-18 (L type)
First Insert metal bush to connector,
Insert cable straight into theconnector so that the
center conductor may enter a center pin.

Step-19 (L type)
Tighten lock nut.
Don't turn connector side. Turn only lock nut.
Space between lock nut and connector, 1.5mm is limits.
Don’t tighten lock nut strongly.
If lock nut is tightened very strongly, Outer shield will be torn off in the connector.

completed
Note in Installation:

When the IF cable connect to IDU and ODU


Must orderliness the IF cable befor tighten the connector
Don't turn connector side when orderliness the IF cable
Don’t shake the IF cable when tighten the connector