0% found this document useful (0 votes)
57 views2 pages

2-Wire Transmitter Isolator / Current Isolator: Application

This document summarizes a 2-wire transmitter isolator/current isolator product. It is a 1 or 2 channel device that provides galvanic isolation and surge protection for control systems. It has excellent accuracy below 0.05% and a fast response time under 5ms. It is powered by the host loop voltage, has a wide voltage range of 6-35V, and mounts easily on a DIN rail.

Uploaded by

m users
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
57 views2 pages

2-Wire Transmitter Isolator / Current Isolator: Application

This document summarizes a 2-wire transmitter isolator/current isolator product. It is a 1 or 2 channel device that provides galvanic isolation and surge protection for control systems. It has excellent accuracy below 0.05% and a fast response time under 5ms. It is powered by the host loop voltage, has a wide voltage range of 6-35V, and mounts easily on a DIN rail.

Uploaded by

m users
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

2-wire transmitter isolator / current isolator

3186
– 1 or 2 channel 2-wire transmitter isolator / current isolator
– 1:1 conversion in the range 3.5...23 mA
– Low channel voltage drop and fast response time < 5 ms
– Excellent accuracy, better than 0.05%
– Slimline 6 mm housing

Application
Applications
• 3186A is a 1:1 output loop-powered 2-wire transmitter isolator
that excites and measures passive input signals.
• 3186B is a 1:1 output loop-powered 2-wire current isolator
that measures active input signals.
• A very competitive choice in terms of both price and
technology for galvanic isolation.
• Provides surge suppression and protects control systems
from transients and noise.
• 3186 eliminates ground loops and can be used for measuring
floating signals.
• The device can be mounted in Safe area or in Zone 2 and Cl.
1 Div 2. area.

Technical characteristics
• 3186 is powered by the host loop voltage.
• Wide supply range from 6...35 V.
• Low input to output voltage drop typ. 2.5 V (3186A).
• Low input drop ≤ 3 V (3186B), even when no loop power is
applied to the output terminals.
• Excellent conversion accuracy, better than 0.05% in the range
3.8…20.5 mA.
• Signal range is 3.5...23 mA which means that 3186 is
NAMUR NE43 compliant.
• Inputs and outputs are floating and galvanically separated.
• High galvanic isolation of 2.5 kVAC.
• Fast response time < 5 ms.
• Excellent signal/noise ratio > 60 dB.

Mounting / installation
• DIN rail mounting with up to 330 channels per meter.
• Extended operating temperature range from -25...+70°C.

This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information
purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability
Environmental Conditions Output specifications
Operating temperature................................... -25°C to +70°C Current output
Storage temperature...................................... -40°C to +85°C Signal range................................................... 3.5...23 mA
Calibration temperature................................. 20...28°C
Relative humidity............................................ < 95% RH (non-cond.) Signal range, input to output.......................... 3.8...20.5 mA
Protection degree........................................... IP20 Output loop current limitation,
typ.................................................................. 24 mA
Installation in.................................................. Pollution degree 2 &
measurement / overvoltage Current output overload, max........................ 50 mA
cat. II
I.S. / Ex marking
Mechanical specifications ATEX.............................................................. II 3 G Ex nA IIC T4 Gc
Dimensions (HxWxD)..................................... 113 x 6.1 x 115 mm IECEx............................................................. Ex nA IIC T4 Gc
Weight approx................................................ 70 g FMus.............................................................. Cl. I, Div. 2, Gp. A, B, C, D T4
DIN rail type................................................... DIN EN 60715/35 mm or Cl. I, Zone 2, AEx nA IIC T4
Wire size........................................................ 0.13 x 2.5 mm2 / AWG 26...12 FMca.............................................................. Cl. I, Div. 2, Gp. A, B, C, D T4
stranded wire or Cl. I, Zone 2, Ex nA IIC T4
Screw terminal torque.................................... 0.5 Nm
Vibration......................................................... IEC 60068-2-6 Observed authority requirements
2...25 Hz......................................................... ±1.6 mm EMC............................................................... 2014/30/EU
25...100 Hz..................................................... ±4 g LVD................................................................ 2014/35/EU
RoHS.............................................................. 2011/65/EU
Common specifications EAC................................................................ TR-CU 020/2011
Supply
Supply voltage............................................... 6...35 VDC Approvals
Power dissipation, per channel...................... 50 mW (3186A) ATEX 2014/34/EU.......................................... KEMA 10ATEX0147 X
Power dissipation, per channel...................... Vterminal x I (3186B) IECEx............................................................. KEM 10.0068X
FM.................................................................. FM17US0004X /
Isolation voltage FM17CA0003X
Isolation voltage, test / CCOE............................................................. P337347/1 (Pending for
working........................................................... 2.5 kVAC / 300 VAC 3186B)
(reinforced) EAC Ex TR-CU 012/2011.............................. RU C-DK.GB08.V.00410
Zone 2 / Div. 2................................................ 250 VAC (Pending for 3186B)
DNV-GL Marine............................................. Stand. f. Certific. No. 2.4
Response time DNV-GL Marine............................................. Pending for 3186B
Response time (0...90%, 100...10%)............. < 5 ms UL................................................................... UL 61010-1
Signal / noise ratio......................................... > 60 dB
Signal dynamics, input................................... Analog signal chain
Signal dynamics, output................................. Analog signal chain
Accuracy........................................................ Better than 0.05%
Cut-off frequency (3 dB)................................. 100 Hz
EMC immunity influence................................ < ±0.5% of span
Extended EMC immunity: NAMUR
NE21, A criterion, burst.................................. < ±1% of span

Input specifications
Current input
Measurement range....................................... 3.5...23 mA
Input to output voltage drop,
typ.................................................................. 2.5 V (3186A)
Input voltage drop typ.: Supplied
and non-supplied unit..................................... ≤ 3 V (3186B)
2-wire transmitter supply................................ 3.5...32.5 V
Signal conversion........................................... 1:1
3186-031918